Вы находитесь на странице: 1из 3

POWER QUALITY ANALYZER

KEW 6315

Simultaneous recording of Power & Power Quality measurements in one survey..


The perfect tool for Energy Saving and Power Quality control.

Simultaneous Power & Power quality Remote monitoring on PC and Android device
measurements Remote checking of measurement in real-time is possible via Bluetooth
Power/ Harmonics/ Waveform/ Power quality are communication. Recorded data can be saved in the supplied SD card.
recorded at all CHs. (Voltage: 3ch, Current 4ch) EN50160 report can be generated after survey by PC software.
Helpful support functions Various Clamp Current Sensors
Quick Start Guide, Wiring check and Sensor detection Various types of clamp and flexible sensors are available: from
for easy and reliable measurement 1000mA Range up to 3000A Range and Earth leakage measurements
Measurement with high accuracy Energy consumption check on site
Guaranteed accuracy: 0.3%rdg (energy), Trend and demand graphs for easy recognition.
0.2%rdg (voltage/ current) TFT color display with high resolution.
Complies with the International Standard
IEC61010-1 CAT 300V, CAT 600V, CAT1000V
IEC61000-4-30 Class S and the European Standard EN50160
Easy-to-use setting to simultaneous power energy and
power quality recordings
POWER QUALITY ANALYZER KEW 6315
Quick Start Guide Easily and securely One-Touch START/STOP Key for Quick Start Guide Windows software for data Real time and Remote
starts recording providing easy setup guides. measurements
analysis and setting via USB port
Automatic creation of graph and list from recorded data.
Uniform management of setting and recorded data ac-
quired from multiple devices.
Data can be expressed in crude oil and M easurements can be
CO2 equivalent values in the report. graphically displayed on
Android devices or PC in
System requirements for POWER QUALITY

real-time via Bluetooth


ANALYZER

KEW 6315
OSWindows 8/7/Vista/XP

Copyright
KYORITSU ELECTRICAL
INSTRUMENTS WORKS, LTD.
2013

DisplayXGA Resolution 1024768 dotsor more communication.


Guide start Connect to the circuit Wring check Select interval Set recording time Start recording Hard-disk: Space required 1Gbyteor more

OtherWith CD-ROM drive and USB port,


KYORITSU ELECTRICAL INSTRUMENTS WORKS, LTD. Japan

www.kew-ltd.co.jp

NET Framework (3.5 or more)


Windowsis registered trademark of Microsoft in the United States.

Print Screen
Power & Energy Waveform
This function takes a color photo of the display screen and saves it as BMP file useful for reports.

Instantaneous value Displays voltage and current Bluetooth is a registered trademark of the
on each Ch by waveform. Bluetooth SIG, Inc.
Android is a registered trademark of the
Scales of voltage/current Google Inc.
axis and time axis are se-
lectable, and also full-scale
function for automatic scal-
ing is available. USB Terminal
List Zoom8-split Zoom4-split

Measures instantaneous / average / min / max for voltage, Digital Output Terminal
current, active / reactive / apparent power, PF (cosfi) and line
frequency all on one screen. Harmonics Analysis Open Collector Output (1ch)

The recording time for these parameters can be set from 1


second up to 2 hours in several steps. Analogue Input Terminal
Trend of all main parameters and customized Zoom functions. 2ch DC100mV / 1000mV, 10V. To
Trend record additional parameters (i.e.
Function to define size of capacitor banks of PF correction unit.
Lux, Temperature, Humidity,etc.)
Integration value
The display will list the active / reactive / apparent energy in
total and for each phase consumed (or generated in case of Graph List
SD card Interface
co-generation like solar panels, etc). SD cards up to 2GB can be used
The elapsed time is also shown on the same display screen. Graphic display of harmonic components up to 50th Possible recording time
order for voltage, current and power in total and for When the 2GB of SD is used:
each phase.
REC item
List display of harmonic content, rms value and phase Interval
Power Harmonics
Demand angle of each order. 1sec 13days 3days
Can analyze harmonic currents that may contribute 1min 1-year or more 3mounths
to damage capacitor banks for PF correction, over- 30min 10-year or more 7-year or more
heating transformers / neutral conductors / cables, Data of power quality events are not considered to
unwanted tripping of breakers. estimate the possible recording time. The max pos-
sible time will be shortened by recording such events.

Measurement Change in specific period Demand change Power Quality Dip Flicker
To support demand control, present energy usage and estimated value are dis- Dip, as the opposite of a swell, is a instantaneous voltage
played on a graph while recording max demand value and the occurred time. decrease, most of the time caused by switching ON large Designed to meet IEC61000-4-15
Event load e.g. motors or by downstream power line failure.
Flicker is a phenomenon giving an impression of un-
Measures voltage swells / dips /
Interruption steadiness of visual sensation induced by periodic volt-
interruptions / transients and inrush
Interruption is a power line cut-off from any source of age changes caused by fluctuating loads when using:
currents that may indicate a weak
arc furnace, spot welder, crane, excavator, etc..
Vector and Wiring check power distribution system. Such supply. It can be caused by a fault in a power line, which
phenomena may damage or reset causes switch gear to open.
devices. KEW 6315 can catch swells
Transients/Over Voltage (Impulse)
/ dips / interruptions and inrush cur-
Transient is a very fast and momentary voltage increase
rents based on half cycle (10 ms @
that can seriously damage devices connected to a pow-
50Hz or 8.3ms @ 60Hz) TRMS.
er line. It may be caused by electrical switching events
All necessary data is displayed by
such as instable contacts of relays, tripping of breakers
pressing one key.
Swell but also by lightening. KEW 6315 can catch Transients
Swell is a instantaneous voltage increase, most of the from 2.4 s.
time originated by upstream power line failure or switch- List Trend graph
Vector Wiring check Ideal vector Inrush Current
ing OFF large Displays Pst (1min) on a trend graph.
Inrush current is a surge current that happens when
Can display voltage and current by vector per CH and also unbalance ratio. load or switching
motors, large or low-impedance loads are switched ON.
Wiring check function confirms connection and displays ideal vector (at the ON large capaci-
Then the current will stabilize as soon as the load has
lower left corner) according to the selected wiring system, and shows con- tor.
reached normal working conditions.
nection errors.
Optional
Load current clamp sensors Load current flexible clamp sensors
MODEL 8128 MODEL 8127 MODEL 8126 MODEL 8125 MODEL 8124 KEW 8129

MAX MAX MAX MAX MAX


50A 24 100A 24 200A 40 500A 40 1000A 68 8129-01 (for 1ch)
8129-02 (for 2ch) MAX

Leakage &Load current clamp Power supply Magnetic carrying 8129-03 (for 3ch) 3000A 150
adaptor case
KEW 8146 KEW 8147 KEW 8148
MODEL 8312 MODEL 9132 KEW 8130

MAX MAX MAX


30A 24 70A 40 100A 68
MAX
1000A 110
8146/8147/8148 can measure up to 10A

Can you close your distribution board door during Set Model
surveys?
The KEW6315 facilitates safe testing by being extremely
KEW 6315-01
8125(500A)3
compact and with two clever option extras: a magnetic
case(9132) for attaching it to the sides of metal enclosures KEW 6315-03
and a power supply adaptor(8312) which takes the power 8130(1000A)3
for the instrument from the supply being measured.

KEW6315-03

Specifications
Wiring connections 1P2W, 1P3W, 3P3W, 3P4W Frequency meter range 4070Hz
Measurements and Voltage, Current, Frequency, Active power, Reactive power, Power supply(AC Line) AC100240V/5060Hz/7VA max
parameters Apparent power, Active energy, Reactive energy, Alkaline size AA battery LR6 or Ni-MH(HR15-51)6
Apparent energy, Power factor (cos), Neutral current, Power supply(DC battery)
Battery life approx. 3 h (LR6, Backlight OFF)
Demand, Harmonics, Quality (Swell/Dip/Interruption,
Internal memory FLASH memory (4MB)
Transients/Over voltage, Inrush current, Unbalance rate),
Capacitance calculation for PF correction unit, Flicker PC card interface SD card (2GB)
Voltage (RMS) PC communicationinterface USB Ver2.0, Bluetooth Ver2.1+EDR Class2
Range 600.0/1000V Display 320240(RGB)Pixel, 3.5inch color TFT display
Accuracy 0.2rdg0.2%f.s.(sine wave, 4070Hz) Display update period 1 sec
Allowable input 1120% of each range (rms). 200% of each range (peak) Temperature and humidity range 235less than 85% RHwithout condensation
Display range 0.15130% of each range Operating temperature
045leaa than 85% RHwithout condensation
and humidity range
Crest factor 3 or less
Storage temperature and
Sampling speed of -2060less than 85% RHwithout condensation
2.4s humidity range
Voltage transient Applicable Standards IEC61010-1 CAT 300V, CAT 600V,
Current (RMS) CAT 1000VPollution degree 2
Range 8128 (50A type) 5/50A/AUTO IEC61010-2-030, IEC61010-031, IEC61326, EN50160
8127 (100A type) 10/100A/AUTO IEC61000-4-30Class S, IEC61000-4-15, IEC61000-4-7
8126 (200A type) 20/200A/AUTO Dimension/Weight 175L 120W 68Dmm/approx 900g
8125 (500A type) 50/500A/AUTO Included accessories 7141BVoltage test lead, 7170Power cord,
8124/8130 (1000A type) 100/1000A/AUTO 7219USB cable,8326-02SD card 2GB,
8146/8147/8148 (10A type) 1/10A/AUTO 9125Carrying case for KEW6315)
8129 (3000A type) 300/1000/3000A 9135Carrying case for KEW6315-03, Input terminal plate6,
Accuracy 0.2%rdg0.2%f.s.+accuracy of clamp sensor (sine wave, 4070Hz) KEW Windows for KEW6315software, Calibration Certificate
Allowable input 1110% of each range (rms). 200% of each range (peak) Quick manual, Alkaline size AA batteryLR6
6
Optional accessories 8124, 8125, 8126, 8127, 8128Load current clamp sensor,
Display range 0.15130% of each range
8129, 8130Flexible clamp sensor,
Crest factor 3 or less 8146, 8147, 8148Leakage and Load current clamp sensor,
Active power 8312Power supply adapter, 9132Magnetic carrying case
0.3%rdg0.2%f.s. + accuracy of clamp sensor
Accuracy
(power factor 1, sine wave, 4070Hz
Influence of power
1.0%rdg (reading at power factor 0.5 against power factor 1)
factor

Please read the "Safety Warnings" in the instruction manual supplied with the instrument thoroughly and completely
Safety Warnings : for correct use. Failure to follow the safety rules can cause fire, trouble, electrical shock, etc. Therefore, make sure
to operate the instrument on a correct power supply and voltage rating marked on each instrument.

For inquires or orders :

2-5-20, Nakane, Meguro-ku, Tokyo, 152-0031 Japan


Phone:+81-3-3723-0131
Fax:+81-3-3723-0152
E-mail:info-eng@kew-ltd.co.jp