B B

WITTUR HYDRA PLUS DOOR CONNECTION DIAGRAM

127V AC
CAM

230V AC

TRANSFORMER
C + C
2001

0V
M
CONTROL PANEL

810 A

PE
-
L2
220V AC
L1

PE
X3 X4
X1
KO/COM COM
KK/I1 OPEN I1 / OPEN HYDRA PLUS
D KA/ I2 CLOSE I2 / CLOSE
I3
DOOR BOARD D

I4
X2
NO (Normally Open)

REOPEN
K20
1000 O3 (Common)
NC (Normally Closed) - + X5
120
LANDING DOOR
130
CONTACT 24V DC
E
140 BATTERY E

CAR DOORS 12V/1.2Ah 12V/1.2Ah


CONTACT - + - +

F F

1) CAM terminals (2001-810) are not used if car and landing doors are full-automatic
G G

2) If cabin door is automatic and landing doors are manual then:


Landing door contacts are serially connected to 120-130 terminals.
Landing door lock contacts are serially connected to Car door contact (130-140) terminals.

F/7.5.5.02.02
H
AX SERIES WITTUR HYDRA PLUS H
This document is a sample for applications. All information contained in DOOR BOARD CONNECTION DIAGRAM
these materials are subject to change by Aybey Elektronik without notice.
AYBEY SERIES AX DRW. M. AKKU
Aybey Elektronik assumes no responsibility for any damage, liability, or
PROJ. AX063 APPRV. M. AYBEY
other loss rising from these inaccuracies or errors. ELEKTRONK
REV. 00 DATE 09 FEB 06