Вы находитесь на странице: 1из 3

DVI Connectors XM4M

Transfer High-resolution Video Signals


with OMRONs DVI-compliant Digital
Visual Interface Connectors.
Used for both digital video (TMDS) and conven-
tional analog (RGB) signals.
OMRONs DVI Connector is an analog interface
capable of up to 2.5-GHz bandwidths.
Transfers broadband data up to 9.9 Gbps (dual
link) to ensure full compatibility with advanced
broadband applications.
Shielded against EMI for high-speed data transfer.
Digital and digital/analog models available.

RoHS Compliant

Terminology
z DVI z bps
Abbreviation for Digital Visual Interface. Abbreviation of Bits Per Second.
One of the specifications for connecting a PC and display. Unit of data speed expressing the number of bits that can
Using the DVI, you can directly send digital signals from a be transmitted in one second.
PC to the display. 1 bps means 1 bit of data can be transmitted per second.
z TMDS z EMI
Abbreviation for Transition Minimized Differential Signaling. Abbreviation of ElectroMagnetic Interference (noise).
A digital transmission method of the display video signal
used for the DVI.
z RGB
Three video signals of R (Red), G (Green) and B (Blue).

Ordering Information
Type Digital Digital/Analog
Accessories No anchors Inch screws, No anchors Inch screws,
length = 5.8 mm length = 5.8 mm
Model XM4M-2432-5012 XM4M-2432-1312 XM4M-2932-5012 XM4M-2932-1312
Appearance

Ratings and Characteristics Materials and Finish


Type Digital Digital/Analog Housing PBT (UL94 V-0)/natural
Item Cover PBT (UL94 V-0)/natural
Rated current 1.5 A Con- Mating Copper alloy/nickel base, gold plating
Rated voltage 40 VAC tact end
Contact resis- 30 m max. (at 20 mVDC, 100 mA max.) Termi- Copper alloy/nickel base, tin plating
tance nal
Insulation resis- 1,000 M min. (at 500 VDC) Shell Steel/nickel plated
tance Anchors Steel/nickel plated
Dielectric strength 500 VDC for 1 min (leakage current: 0.5 mA Grounding Fix- Copper alloy/tin plated
max.) ture
Insertion durability 100 times
Ambient operating 20 to 85C (with no condensation or icing)
temperature

1
Dimensions (unit: mm)

XM4M-2432-1312
Mounting holes (t = 1.6 mm, bottom view)

30.73 0.1
19.05 0.1
Four, 1.93 +0.1
0
dia. 5.84 0.05
18.2 Board terminals

5.8 6.5 3.3 0.05

24.03 1.93 0.05 Pin 24


1.905 0.05 Pin 1 24, 0.86 +0.1
0
dia.
36.78 #4-40 UNC
32.51 1.905 0.05 1.905 0.05
17.78
13.335 13.335 0.1
1.905 1.905

9.9 7.72 Panel dimensions (For XM4M-2432-501@) (t = 1.2 mm max.)


4.95
2.5 32.51 0.05 Two, R0.64 0.1
1.905 27.43 0.05
Two, 3.05 +0.1 dia.
1.905 2.7 2.03 2.73 0

13.335 3.3
19.05 1.905 9.14 0.05
30.73
2.54 0.05 Two, R2.54 0.1

XM4M-2932-1312
Mounting holes (t = 1.6 mm, bottom view)
30.73 0.1
Six, 0.66 +0.1 dia. 19.05 0.1
0
5.84 0.05 2.67 0.05
Board
18.2 0 dia.
Four, 1.93 +0.1 terminals 3.94 0.05
2.54 0.05
5.8 6.5 3.3 0.05
5.08 0.05
24.03
1.93 0.05 1.27 0.05
Pin 1 2.54 0.05
#4-40 UNC 1.905 0.05
36.78 24, 0.86 +0.1
0
dia.
32.51 1.27 1.905 0.05
13.335 2.54 1.905 0.05
1.27 2.54
1.905 1.905 13.335 0.1

9.9 7.72
4.95
Panel dimensions (For XM4M-2932-501@) (t = 1.2 mm max.)
2.03 2.5
1.905 32.51 0.05 Two, R0.64 0.1
1.27 2.73 27.43 0.05
1.905 2.7
2.54 2.66 Two, 3.05 +0.1
0
dia.
13.335 3.3
19.05 3.94 2.54
30.73 9.14 0.05
5.08
1.905
2.54 0.05 Two, R2.54 0.1

Terminal layout
Digital/Analog sharing type terminal Arrangement
Terminal layout viewed from the mating surface Board terminal arrangement (BOTTOM VIEW)
Terminal 9 Terminal 16 Board edge
Terminal 1 Terminal 8 C1 C2 Terminal 17 Terminal 16 C3 C5

Terminal 24
1 8 C1 C2 C4

C3 C4
24 C5

Terminal 9
C1 C2
Terminal 1 Terminal 8
C5
Terminal 17 Terminal 24 C3 C5 C4

Note: The digital type does not have C1 to C5.

Precautions
Precautions for Correct Use
Automated Soldering About panel mount
Soldering Use anchor 3 (XM4Z-002@ series) to lock connectors without
anchors. (For anchor 3, refer to XM3-L/XM-2L/XM4K/XM4L.)
Automated Soldering Conditions (Jet Flow)
1. Soldering temperature: 250 5C Mating
2. Continuous soldering time: Within 51 s
Do not connect the Connectors in the wrong direction, otherwise it
Tightening torque for anchors may be damaged.
To install an anchor on the connector body, tighten it with 0.49 Nm.
Also, use a proper size tool to do this work.

2 DVI Connectors XM4M


Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.

Note: Do not use this document to operate the Unit.

OMRON Corporation
Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. G061-E1-02
1014(0412)(O)

Вам также может понравиться