The Sampling pot shall be fabricated from a Straight pipe welded with End cap at both ends.
Required thickness of Straight pipe at the design condition shall be calculated as per the code
Design Input:
Design Pressure P
Design Temperature T
Mill tolerance MT
tm
The selected thickness for the sampling pot shell pipe is 11.13mm (Sch 160), which is higher than
Hence the selected thickness for sampling pot shell is safe and sufficient
The allowable pressure rating for end caps designed in accordance with the code ASME B16.9 may be
calculated as for straight seamless pipe of equivalent material in accordance with the rules established
The above calculation proving that the minmum required thickness to withstand the design pressure
(3000psi) is 11.13mm.
Hence the selected End cap with wall thickness 11.13mm as per the table 10 of ASME B16.9, shall be
suitable to withstand the design pressure (3000psi)
= 3000 psi
= 230 F
= 3.5 Inch
= SA-312 TP316L
= 16700 psi
= 1
= 1
= 0.4
= 0.0394 Inch
= 12.5%
= PD/2[SEW+PY)]+C
= 0.333 Inch
= 0.380 Inch
= 9.658 mm