Академический Документы
Профессиональный Документы
Культура Документы
Pressure
Reducing
Valves
Direct acting, internally
and externally piloted
pressure reducing valves
and temperature regulators
for steam, air, water,
non-viscous liquids and
non-corrosive gases.
Bringing Energy Down to Earth
Say energy. Think environment.
And vice versa.
Any company that is energy conscious is also environ-
mentally conscious. Less energy means less waste,
fewer emissions and a healthier environment.
2
Table of Contents
Introduction 4
GD-30 7
GD-50 8
GD-6N, GD-6 9
GD-24 11
GD-20 12
GP-11S 19
Capacity Chart
(GP-2000, 2000K-1, 2000K-2, GD-2000K,
GP-2000R, GP-11S) 26
GP-2000 (On/Off) 27
Temperature Regulators 28
Typical Installation 35
Sizing Data 39
3
Helping You Make the Most of Your Resources
Armstrong pressure reducing valves Direct Acting. The simplest of Externally Piloted. In this type,
(PRVs) and temperature regulators PRVs, the direct acting type oper- double diaphragms replace the
help you manage steam, air and ates with either a flat diaphragm or piston of the internally piloted
liquid systems safely and efficiently. convoluted bellows. Since it is self- design. This increased diaphragm
And assure uninterrupted productiv- contained, it does not need an external area can open a larger main valve,
ityby maintaining constant pres- sensing line downstream to operate. allowing a greater capacity per line
sure or temperature for process It is the smallest and most economi- size than the internally piloted valve.
control. In short, Armstrong products cal of the three types and designed In addition, the diaphragms are more
make using resources safe and for low to moderate flows. Accuracy sensitive to pressure changes, and
productiveas well as environmen- of direct acting PRVs is typically +10% that means accuracy of +1%.
tally sound. of the downstream set point. This greater accuracy is due to the
location, external of the valve, of
For decades, Armstrong has Internally Piloted Piston- the sensing line where there is less
devoted itself to learningand Operated. This type of PRV incor- turbulence. This valve also offers
sharingall it can about energy porates two valvesa pilot and the flexibility to use different types
conservation as it relates to steam main valvein one unit. The pilot of pilot valves (i.e., pressure,
equipment. As part of our product/ valve has a design similar to the temperature, air loaded, solenoid
service network, PRVs and tempera- direct acting valve. The discharge or combination).
ture regulators represent expanded from the pilot valve acts on top of a
options for a reliable Armstrong piston which opens the main valve.
solution. This design makes use of inlet
pressure in opening a larger main
PRV Types valve than could otherwise be
Steam, liquids and gases usually opened. As a result, there is a
flow at high pressures to the points greater capacity per line size and
of final use. At these points, a greater accuracy (+5%) than with
pressure reducing valve lowers the the direct acting valve. As with
pressure for safety and efficiency direct acting valves the pressure
and to match the requirements of the is sensed internally eliminating the
application. There are three types need for an external sensing line.
of pressure reducing valves.
4
Pressure Reducing Valve Selection
If Inlet If Outlet If Maximum Capacity Find on
If the Fluid is Look for Model
Pressure is Pressure is is Less Than Page
From 32F
Self-Contained
15 to 150 to 302F +7F 1,745 lbs/hr OB-30 29
Direct Acting
5 Ranges
Heating
From 18F OB-2000 31
Self-Contained
10 to 285 to 361F +2F 58,032 lbs/hr
Pilot Operated 6 Ranges OB-2000PT 33
5
Direct Acting
For Steam, Air, and Non-Corrosive Gas Service
The simplest of pressure reducing self-contained, it does not need an designed for low to moderate flows.
valves, the direct acting type external sensing line downstream to Accuracy of direct acting PRVs is
operates with either a flat diaphragm operate. It is the smallest and most typically +10%.
or convoluted bellows. Since it is economical of the three types and is
Downstream pressure
sensed outside the
Hardened stainless steel bellows vs. inside, which
valve and seat with assures bellows integrity
spring return to assure and longer bellows life.
tight shutoff.
6
Direct Acting
GD-30
For Steam, Air, and Non-Corrosive Gases
The GD-30 is a compact, high +10% is acceptable. The GD-30 food processing. It provides tight
performance direct acting valve. is well suited for laundry and dry shutoff for dead-end service on
Economical to buy and use, its cleaning equipment, hospital steam and can be mounted in
ideal for those low to moderate flow equipment, tire molds, humidifiers, any position.
applications where accuracy of small heaters and applications in
Table 7-1. GD-30 Specifications
MATERIALS
Inlet Reduced Minimum Maximum
Service Pressure Pressure Differential Temperature
(psig) (psig) (psig) (F) Body Valve/Seat Bellows
64 176 205 342 738 1,168 140 485 573 948 2,060 3,195
54 187 225 353 782 1,201 115 496 584 961 2,071 3,207
80 225
23 121 137 220 489 749 85 463 540 904 1,983 3,063
8 60 77 108 231 363 23 254 298 496 1,079 1,675
80 203 242 397 863 1,355 140 525 606 1,014 2,226 3,438
66 225 262 437 958 1,465 120 551 584 1,038 2,248 3,471
100 250
40 198 231 375 837 1,278 70 463 529 893 1,939 2,997
10 68 79 132 297 473 25 276 320 529 1,146 1,796
NOTE: For air capacities (SCFM), multiply steam capacities by 0.36.
Maximum pressure reduction ratio 10:1
GD-30
All dimensions and weights are approximate. Use certified print for exact dimensions. 7
GD-50 Pressure Reducing Valve
For Steam, Air and Non-Corrosive Gas Service
The GD-50 is a compact, high- applications which do not justify the hospital equipment, tire molds,
performance direct-acting valve. higher cost of pilot-controlled valves. humidifiers, small heaters and
Inexpensive to buy and use, it is The GD-50 is well suited for laun- applications in food processing.
ideal for those moderate flow dry and dry cleaning equipment, It provides tight shutoff for dead-
end service on steam.
Table 8-1. GD-50 Specifications
MATERIALS
Inlet Reduced Minimum Maximum
Service Pressure Pressure Differential Temperature
(psig) (psig) (psig) (F) Body Valve/Seat Bellows
All dimensions and weights are approximate. Use certified print for exact dimensions.
8
Direct Acting
GD-6N (Steam), GD-6 (Liquid, Gas)
For Steam, Air and Water
The GD-6N and GD-6 are compact, valves mount in any position and steel diaphragm, hardened
direct acting diaphragm valves require no external sensing lines or stainless steel working parts (6N),
ideal for low-flow applications, additional parts. External adjusting integral removable strainer (6N)
including laundry/dry cleaning screw with locking nut and cover and in-line renewable valve and
equipment, hospital equipment, tire/ make for quick, easy setting and seat. Available in 3/8", 1/2", 3/4" and 1"
plastic molds and food processing. adjustment. Tight shutoff for dead- sizes with a choice of two set
Lightweight and compact, the end service. Removable stainless pressure spring ranges.
H1
L
GD-6N
All dimensions and weights are approximate. Use certified print for exact dimensions.
9
GD-10, GD-10F, AF-10
For Air and Non-Corrosive Gases
The GD-10/10F is a lightweight Zinc or aluminum bodies eliminate rust dead-end service. GD-10 available
direct acting diaphragm valve used and scale. Plug, seat and diaphragm in sizes 1/4" - 2". Highly efficient
primarily for pneumatic tool air supply are renewable in-line, and you can Model AF-10 air filters with zinc or
and non-hazardous gas regulation. make quick adjustments externally with aluminum bodies are used to
Screwed connections make it easy locking handle. Quarter-inch pressure remove liquids and solid particles
to support in any position without gauge connection is standard, and all from compressed air. The AF-10
external sensing lines or other parts. units are capable of tight shutoff for is available in sizes 1/4" - 1".
Table 10-1. GD-10/GD-10F/AF-10 Specifications
Inlet Reduced Minimum Maximum MATERIALS
Model Application Pressure Pressure Differential Temperature
(psig) (psig) (psig) (F) Body Bowl Main Valve Valve Plug Diaphragm
Air and Other Zinc Zinc Brass
GD-10 Non-Corrosive 0-300 5-125 7 175 / ", / ", / ", / "
14 3 8 1 2 34 / ", / ", / ", / "
14 3 8 1 2 3 4 / ", / ", / ", / "
14 3 8 1 2 3 4 Nitrile
Gases Aluminum 1"-2" Aluminum 1"-2" Nylon 1"-2"
Air and Other
GD-10F Non-Corrosive 0-250 5-125 7 175 Zinc Zinc Zinc Brass Nitrile
Gases
Air and Other Zinc Zinc
AF-10 Non-Corrosive 0-250 175 / ", / ", / ", / " 1/4", 3/8", 1/2", 3/4"
14 3 8 1 2 34
Gases Aluminum 1" Aluminum 1"
NOTE: For 1/2" 316 stainless steel air valve, consult factory.
Table 10-2. GD-10 Dimensions and Weights Table 10-3. GD-10F Dimensions and Weights Table 10-4. AF-10 Dimensions and Weights
Connection Size Connection Size
Symbol /"
14 / " 1/2"
38 /"
34 1" 11/4" 11/2" 2" Symbol /"
14 /"
38 /"
12 /" 34 Symbol /"
14 38/" /"
12 /"
34 1"
L (in) 25/8 25/8 25/8 31/2 41/4 6 L (in) 23/4 23/4 23/4 3 /8
7 L (in) 2 3/4 23/4 23/4 37/8 43/4
H (in) 53/8 53/8 53/8 57/8 71/8 93/4 H (in) 93/8 9 3/8 9 3/8 107/8 H (in) 63/8 63/8 63/8 7 113/8
H1 (in) 11/2 11/2 11/2 11/2 23 8 / /
3 9 16 H1 (in) 53/4 53/4 53/4 63/8 H1 (in) 53/4 53/4 5 3/4 63/8 10
Wt (lbs) 11/2 11/2 11/2 2 3 10 Wt (lbs) 21/2 21/2 41/2 41/2 Wt (lbs) 2 2 2 2 3
CV 1.4 1.4 1.4 2.6 5.8 43 CV 1.4 1.4 1.4 2.6
L
GD-10 GD-10 2" GD-10F AF-10
H H H
H1 H
H1
H1 H1
L L
L
Table 11-2. GD-24 CapacitiesWater (GPM) Table 11-3. GD-24 Dimensions and Weights
P Connection Size Connection Size
(psig) 1/2" 3/4" 1" 11/4" 11/2" 2" Symbol /"
12 /"
34 1" 11/4" 11/2" 2"
7 3 4 7 9 16 22 L (in) 31/4 31/2 4 43/4 6 71/4
10 5 6 10 13 22 32 H1 (in) 13/4 2 2 /2
1 31/4 31/2 41/2
15 6 7 12 16 27 39 H (in) 73/4 81/2 9 /8
5 111/4 131/2 16
25 8 10 15 20 35 50 Wt (lbs) 4 51/4 7 /4
1 10 3/8 18 311/2
50 11 14 21 28 50 71 Cv 1.5 2 3 4 7 10
75 13 17 26 35 61 87
100 15 19 30 40 70 100
125 17 21 34 45 78 112
150 18 23 37 49 86 123
175 20 25 40 53 93 132
200 21 27 42 57 99 141
NOTE: Maximum pressure reduction ratio 10:1
H1
L
GD-24
All dimensions and weights are approximate. Use certified print for exact dimensions. 11
GD-20
For Air, Water, Non-Corrosive and Non-Viscous Liquids
The GD-20 offers high capacity and service life. Well suited to non- commercial air conditioning.
highly accurate control with a large, viscous liquid pressure reduction, Upstream variations do not affect
cupped diaphragm for a long stroke. the valve is widely applied in balanced pressure valve, and
Compact and rugged, the GD-20s domestic water applications, composition disc assures tight
composition valve and bronze seat construction equipment, irrigation, shutoff. Turndown ratio is 10:1,
mean high performance over a long tank car loading and industrial or and sizes range from 2" through 6".
Table 12-2. GD-20 CapacitiesAir (SCFM) Table 12-3. GD-20 CapacitiesWater (GPM)
Inlet Outlet Connection Size
P Connection Size
(psig) (psig) 2" 21/2" 3" 4" 5" 6"
(psig) 2" 2 1/2" 3" 4" 5" 6"
15 8 283 512 658 1,243 1,371 1,975
13 196 342 440 831 917 1,320 7 36 63 81 152 168 242
20 10 51 89 114 215 237 342
2-10 340 598 769 1,452 1,602 2,307
15 62 109 140 263 291 418
18 233 408 525 991 1,094 1,575 161
20 72 125 304 336 483
25 15 320 558 717 1,354 1,494 2,151 25 80 140 180 340 375 540
2-12 396 684 880 1,662 1,833 2,639 35 95 166 213 402 444 639
23 270 474 609 1,150 1,268 1,826 50 113 198 255 481 530 764
75 139 242 312 589 650 935
30 20 340 596 767 1,448 1,598 2,300
85 148 258 332 627 691 996
3-15 441 1,024 1,316 2,486 2,742 3,949 280 360
100 160 680 750 1,080
32 344 603 775 1,464 1,615 2,325 125 179 313 402 760 838 1,207
40 25 460 797 1,024 1,934 2,134 3,072 143 191 335 430 813 897 1,292
4-20 537 943 1,213 2,291 2,526 3,638 NOTE: Minimum flow is 1.3 GPM.
40 418 728 936 1,769 1,951 2,809
Table 12-4. GD-20 Dimensions and Weights
50 32 544 948 1,218 2,302 2,539 3,656 Face-to- Weight
Size A (in) H (in) H1(in) Cv
5-25 640 1,115 1,433 2,707 2,986 4,300 Face (in) (lbs)
48 491 859 1,105 2,087 2,302 3,315 2" 7 5/8 6 161/4 31/8 16 43
21/2" 10 5/8 7 211/2 41/16 28 88
60 40 620 1,076 1,384 2,614 2,883 4,152
3" 105/8 71/2 22 9/16 4 9/16 36 97
6-30 736 1,288 1,655 3,126 3,448 4,966 4" 121/8 9 251/16 51/4 68 154
60 600 1,051 1,351 2,553 2,816 4,054 5" 15 10 33 61/2 75 317
75 48 780 1,358 1,745 3,297 3,637 5,237 6" 153/4 11 359/16 71/2 108 381
7-37 884 1,546 1,988 3,755 4,141 6,158
90 567 992 1,275 2,408 2,656 3,824 A
100 70 936 1,637 2,105 3,976 4,385 6,315
10-50 1,130 1,977 2,542 4,801 5,295 7,625
100 965 1,688 2,170 4,050 4,521 6,511
125 80 1,242 2,174 2,795 5,280 5,823 8,385
13-60 1,376 2,408 3,096 5,848 6,450 9,288
100 1,430 2,502 3,217 6,076 6,701 9,650
150 90 1,509 2,640 3,395 6,413 7,073 10,185
15-80 1,630 2,852 3,667 6,927 7,640 11,000
H1
12 All dimensions and weights are approximate. Use certified print for exact dimensions.
Internally Piloted
Internally Piloted
For Steam, Air, and Non-Corrosive Gas Service
This type of PRV incorporates two valve acts on top of a piston which As a result, there is a greater
valvesa pilot and main valve opens the main valve. This design capacity per line size and greater
in one unit. The pilot valve has a makes use of inlet pressure in accuracy (+5%) than with the
design similar to the direct acting opening a larger main valve than direct acting valve.
valve. The discharge from the pilot could otherwise be opened directly.
13
GP-100, GP-32, GP-18/28, GP-1
For Steam, Air, and Non-Corrosive Gas
The GP-100, GP-32, GP-18/28, ratings to assure the most econom- strainer team up to provide high
GP-1 Series valves are pilot- ical match to your application. performance over a long, trouble-
controlled for accurate regulation Internally piloted GP-Series valves free service life. Valves are
of pressure under wide-ranging are best suited for use in continu- equipped with a caged main
flow. Internal pilot design elimi- ous distribution applications. valve assembly (separate
nates external components shutoff surfaces and flow control
and piping. Completely supported by piping, ports), piston valve rings for
lightweight GP-Series valves install longer life and an external
Internally piloted GP-Series valves easily with NPT or flanged connec- adjusting screw with locking
are capable of larger capacity and tions. A stainless steel diaphragm, nut and cover. All working parts
greater accuracy than direct acting hardened stainless steel working are renewable in-line. For air
valves. Bodies have three pressure parts and integral removable service, a Teflon seat assures
tight shutoff.
Table 14-1. GP-100, GP-32, 31A/32A, 18/28, 18A/28A, GP-1/1A Specifications
Pressure
Model Maximum Minimum Main Valve/ Pilot Valve/ *Piston/
Number Inlet Reduced Application Temp.(F) Diff.(psig) Body Valve Seat Seat Cylinder Diaphragm
(psig) (psig)
GP-100 Steam 450 Stainless Stainless Steel Piston
GP-32 Steel AISI 420 AISI 403/420 Bronze
15-150 5-125 ASTM C83600
10 Stainless Steel
GP-31A Cylinder
Air & Gas 250 AISI 403/420 Bronze
GP-32A
Cast Iron w/Teflon Disc ASTM C36000
Stainless
ASTM A48 Steel
GP-18 CL30 Stainless Steel
GP-28 Steam 450 AISI 403 AISI 403/420
(Valve) Stainless Steel
5-115 10
GP-18A 30-250 ** Stainless Steel AISI 304
115-175 Air & Gas 250 Stainless AISI 403/420
GP-28A Steel
AISI 420 w/Teflon Disc Stainless Steel
(Seat) Stainless Steel AISI 420
GP-1 Steam 535
Carbon AISI 403/420
5-60
30-300 15 Steel
60-175 ASTM Stainless Steel
GP-1A Air & Gas 250 GR. WCB AISI 403/420
w/Teflon Disc
NOTE: Sizes 2" and below are NPT connections. Sizes 2" and larger are standard with flanged connections.
Models GP-100, GP-32 are available with air-loaded pilots - consult factory.
GP-18/28 & GP-1 maximum reduction ratio 10:1
GP-100, GP-32 maximum reduction ratio 20:1
*AISI 420 stainless steel piston & cylinder available - consult factory.
**6" & 8" GP-28 available only in 5-57 & 57-115 spring. 10" GP-28 available only in 5-57.
14
Internally Piloted
GP-100, GP-32, GP-18/28, GP-1
For Steam, Air, and Non-Corrosive Gases
H
H
H
H1 H1
H1
L L
L
All dimensions and weights are approximate. Use certified print for exact dimensions. 15
GP-100, GP-32, GP-18/28, GP-1
Capacities for Steam, Air, and Non-Corrosive Gas
NOTES: For GP-100, GP-32 capacities, multiply Table 16-1 values by factor listed in Table 16-2.
For GP-31A/32A air capacities (SCFM), multiply steam capacities for GP-31/32 by 0.36.
For GP-18A/28A/1A air capacities (SCFM), multiply steam capacities by 0.36.
Factor .714 .657 .640 .670 .643 .769 .694 .783 .805
16
Externally Piloted
For Steam Service
This type is similar to the internally capacity per line size than the downstream where there is less
piloted piston-operated valve in that internally piloted piston-operated turbulence. This valve also offers
a pilot and main valve are utilized. valve. In addition, the diaphragms the flexibility to use different types
However, double diaphragms are more sensitive to pressure of pilot valves (i.e., pressure, tem-
replace the piston. This increased changes which results in accuracy perature, air loaded, solenoid
diaphragm area can open a larger of +1%. This greater accuracy is due or combination).
main valve, allowing a greater to the positioning of the sensing line
Integral strainer
Enclosed spring chamber protects the pilot valve
eliminates dirt fouling. from failure due to dirt.
Easily removable
Dual stainless steel copper tubing permits
diaphragms provide troubleshooting while
corrosion resistance. valve is in line.
17
GP-2000
For Steam Service
The GP-2000 is a high performance, With a 20:1 rangeability and high Cv, steel working parts are renewable
externally piloted reducing valve the GP-2000 is reliable and accurate in-line. Single seated for dead-end
for large capacity requirements. (+ 1% of pressure set point from 5% service. Available with both NPT and
Typical use is on intermittent service, to 100% of flow) over a long, trouble- flanged connections in 1/2" through
including applications such as heat free service life. Hardened stainless 6" sizes.
exchangers, steam coils, rotating
dryers, process equipment and
heating systems.
3.2 3.2
(82) (82)
F F
2.52
(64) H
H H
H
H2 H2
L
H1 H1 H1
H1
L
A
A A A
1/4 NPT 1/4 NPT
GP-2000
18 All dimensions and weights are approximate. Use certified print for exact dimensions.
Externally Piloted
GP-11S Carbon Steel Body
For Steam Service
The GP-11S is a high-performance, All working parts of the GP-11S
externally piloted reducing valve for are renewable in-line. It also has
larger capacity requirements. Appli- hardened stainless steel working
cations include heat exchangers, parts, double stainless steel
steam coils, rotating dryers, process diaphragms and a single-seated
equipment and heating systems. main valve for dead-end service.
Table 19-2. GP-11S Dimensions and Weights For Capacities, see page 26
Connection Size
Symbol 1/2" 3/4" 1" 11/4" 11/2" 2"
Face-to-Face 6 6 1
6 /4 7 7 9
A (in) 77/8 77/8 87/8 87/8 87/8 107/8
H1 (in) 55/8 55/8 57/8 61/2 61/2 71/2
H (in) 161/4 161/4 165/8 173/4 173/4 201/4
Wt (lbs) 39 39 51 56 56 85
Cv 5.0 7.2 10.9 14.3 18.8 32.0
NOTE: 1/2" Thru 2" standard is integral mount.
GP-11S
H1
All dimensions and weights are approximate. Use certified print for exact dimensions. 19
GP-2000K-1/GP-2000K-2
Air Loaded Valves for Steam
A high performance externally air comes totally assembled and from 5% to 100% of flow. A rugged
piloted pressure reducing valve, requires no field installation except ductile iron body, hardened stainless
the GP-2000K-1/GP-2000K-2 is downstream sensing line and air steel working parts, double
an ideal choice when set point line connection. High Cv, 20:1 stainless steel diaphragms and in-
changes are frequent and access turndown ratio and accurate line repairability add up to reliability
to the PRV is difficult. The valve control + 1% of pressure set point on the job. Single seated for
dead-end service.
Table 20-1. GP-2000K-1/GP-2000K-2 Specifications
Inlet Reduced Maximum Minimum MATERIALS
Application Pressure Pressure Temperature Differential Main Pilot
(psig) (psig) (F) (psig) Body Valve/Seat Valve/Seat Diaphragm Color
NPT
15-300 K-1
7-125 Ductile Stainless
*150 lb Flg Iron Stainless Steel Steel Dark
Steam 15-185 450 7 Gray
ASTM AISI 420 AISI
K-2 A536 301
*300 lb Flg 15-200
15-300
*NOTE: 6" valve standard in remote mount with 125 or 250 lb. ANSI flanges and cast iron body. Consult factory.
For Capacities, see page 26
A2
A2
F
F
H H
H
L
H1 H1 H1
L
A1 A1 A1 A1
GP-2000K-1 GP-2000K-2
1:1 Air to Steam Ratio 1:2 Air to Steam Ratio
20 All dimensions and weights are approximate. Use certified print for exact dimensions.
GD-2000K
Air Loaded Valves for Steam
The GD-2000K is an ideal choice flanged connections for quick, easy less working parts, renewable
when set point changes are fre- installation. It also comes with a in-line. High Cv and 10:1 turn-
quent, access to the valve is difficult durable ductile iron body and down ratio. Single seated for
and steam quality is poor. The GD- features double stainless steel dead-end service.
2000K comes with either NPT or diaphragms and hardened stain-
Table 21-2. GD-2000K Dimensions and Weights For Capacities, see page 26
Face-to-Face (in) H1 H A Weight (lbs)
Size NPT 150# 300# (in) (in) (in) NPT 150# 300# Cv
1/2" 57/8 27/8 9 5/8 77/8 27 5.0
3/4" 57/8 27/8 95/8 77/8 27 7.2
1" 61/4 31/16 10 87/8 35 10.9
11/4" 71/8 31/2 111/8 87/8 43 14.3
11/2" 71/8 31/2 111/8 87/8 43 18.8
2" 9 81/2 91/8 41/4 125/8 107/8 66 72 73 32.0
21/2" 107/8 111/2 43/4 143/4 137/8 135 136 60.0
3" 113/4 121/2 51/2 153/4 137/8 146 152 78.0
4" 131/2 141/8 61/2 191/ 157/8 230 240 120.0
H1
GD-2000K
All dimensions and weights are approximate. Use certified print for exact dimensions. 21
Air Loading Charts
Chart 22-1. GP-2000K 1 & 2
200
How to Use Chart 22-1
Enter the graph at the outlet pressure from the
180 value on the vertical axis.
Move horizontally to the right until the air loading
lines are intersected.
160
Then read vertically below the point of intersection
for the air loading pressure required.
140
Selection Example (Chart 22-2)
2
200
100
Differential Pressure P 125 psig
80
K
00
20
GP
35
4"
30
2"
25 3"
ADDITIONAL AIR REQUIRED
11/2"
20
11/4"
21/2"
15
10 1"
3
/4"
/"
1 2
0
20 40 60 80 100 120 140 160 180 200 220 240 260
22
Air Accessories
Control Panels & Air Loaders
Armstrong Control Panels and Air Panel is of rigid lightweight
Loaders are designed to provide anodized aluminum for easy
the necessary air loading signal to handling and installation.
control any air-operated pressure Control panel comes fully
reducing valve. While designed assembled with gauges suited
specifically to control Armstrong to applications. Panel mate
pressure reducing valves such as and panel mate filter are
the GP-2000K1 & 2, GD-2000K, standard on panels and are
GP-100, GP-33 and GP-34, these also available separately.
panels can remotely control other
air-loaded valves.
Optional: Gauge B and C Ranges - psig (bar) 0-30, 0-60, 0-100, 0-150, 0-200, 0-300
(0-2, 0-4, 0-7, 0-10.5, 0-14, 0-20.5)
Maximum Inlet Air Pressure - psig (bar) 200 (14)
Maximum Outlet Air Pressure - psig (bar) 150 (10.5)
B C (64)
Main valve Polycarbonate AIR LOADING PRESSURE AIR SUPPLY PRESSURE
B C
Table 23-3. SpecificationsPanel MateFilter AIR LOADING PRESSURE AIR SUPPLY PRESSURE
61/2"
(165)
4"
*Panel Mate Filter R (102)
ARMSTRONG
Inlet pressure maximum STEAM / AIR / LIQUID PRODUCTS
Three Rivers , Michigan 49093
Temperature maximum
F (C) 160 (71) 175 (79)
*NOTE: Use an Armstrong AF-10, 5 micron air filter upstream of panel mate to prevent fouling.
23
OBK-2000
Pneumatic Temperature Pilot
A compact pneumatic temperature changes. Brass, stainless steel in temperature shortens the
pilot with broad temperature ranges, bulbs and separate wells are sensitivity tube at point (1) and
the OBK-2000 can be remotely available. moves the invar rod against the
located away from the regulator lever point (3). The lever at this
valve, an advantage not available Reverse-Acting Operation point moves against the spring
with a conventional capillary system. For Heating at point (D) to close the exhaust
During operation, a temperature valve at point (4). This lever
Typical applications include instan- change in the medium being action increases the pressure
taneous or storage tank water controlled creates a change in the control line at point (R)
heaters, air make-up units and in the length of the sensitivity and opens the valve.
manufacturing process operations tube. An increase in tempera-
such as parts washing, die casting ture lengthens the sensitivity Operation Reverse Acting -
and plastic molding. tube (1) and moves the invar For Heating
rod (2) from the lever (3).
Capable of reverse or direct-acting The lever pivots at point B GP-2000-K
Regulator Valve
operation, the OBK-2000 features and is moved so the exhaust (Normally Closed)
a simple design with fewer moving valve (4) is opened by the A
parts for trouble-free operation. spring at (D). This lever action 2 1
Other features include supply and decreases the supply air at
control pressure gauges, a rugged point (S) in the control line B
cast brass housing, and precise and at point (R) and closes the 3
rapid response to temperature regulator valve. A decrease
D
C 6
Table 24-1. OBK-2000 Specifications
Dial adjustment range -F (C) Standard - 50 to 350 (10 to 177) R
7" 2-3/8"
178 mm 61 mm
OBK-2000
24 All dimensions and weights are approximate. Use certified print for exact dimensions.
GP-2000R
For Steam Back Pressure Regulation
The GP-2000R is a high performance would include those systems utiliz- constant upstream pressure.
externally piloted throttling back ing flash steam for low pressure This valve is not a safety valve
pressure valve for large capacity heating or processes. The GP-2000R and should not be used for
applications. Typical applications valves will function to maintain a that purpose.
Table 25-2. GP-2000R Dimensions and Weights For Capacities, see page 26
Face-to-Face (in) A F H H H1 Weight (lbs)
Size Integral Remote Cv
NPT 150# 300# (in) (in) (in) (in) (in) NPT 150# 300#
/"
12 5 15/16 /
7 15 16 /
6 15 16 17 3/8 15 3/4 634/ 34 5
/"
34 5 15/16 7 15/16 6 15/16 17 3/8 15 3/4 6 3/4 34 7.2
1" 615/16 8 15/16 7 1/8 17 3/4 15 15/16 6 15/16 44 10.9
11/4" 7 1/8 8 15/16 7 1/8 18 7/8 16 5/8 7 5/8 51 14.3
/"
11 2 /
71 8 /
8 15 16 /
71 8 /
18 7 8 /
16 5 8 /
75 8 51 18.8
2" 9 1/8 8 5/8 9 1/8 10 15/16 7 3/4 213/8 17 1/2 8 1/2 75 81 84 32
/"
21 2 /
10 15 16 111 2/ /
13 13 16 /
8 5 16 /
23 7 8 /
18 13 16 /
9 13 16 142 150 60
3" 113/4 12 7/16 13 13/16 8 3/4 23 7/8 19 7/16 10 7/16 155 166 78
4" 13 1/2 141/8 15 13/16 9 7/16 28 3/8 21 5/8 12 5/8 247 264 120
*6" 18 1/2 19 19 3/4 111/8 25 16 510 550 223
*6" valve standard in remote mount with 125 or 250 lb. ANSI flanges.
F F
1/4 NPT
9" 9"
H
H H H
L
H1 H1 H1
H1 L
A A A A
1/4 NPT 1/4 NPT
GP-2000R
All dimensions and weights are approximate. Use certified print for exact dimensions. 25
GP-2000, 2000K-1, 2000K-2, GD-2000K, GP-2000R, GP-11S
Capacities for Steam
Table 26-1. GP-2000, 2000K-1, 2000K-2, GD-2000K, GP-2000R, GP-11S CapacitiesSteam (lbs/hr)
Inlet Outlet Connection Size
(psig) (psig) /"
12 /"
34 1" 11/4" 11/2" 2" 21/2" 3" 4" 6"
8 201 298 438 575 756 1,287 2,413 3,137 4,826
15 3 250 360 545 716 941 1,602 3,005 3,906 6,010
13 219 316 478 627 825 1,404 2,633 3,423 5,266
20 10 255 368 557 731 962 1,637 3,070 3,992 6,141
3 313 451 683 896 1,178 2,005 3,760 4,888 7,521
18 236 340 515 676 888 1,512 2,836 3,687 5,673
25 3-5 362 522 790 1,037 1,363 2,320 4,351 5,657 8,703
23 252 363 549 721 948 1,613 3,026 3,933 6,052
30 3-7 408 587 898 1,167 1,535 2,613 4,899 6,369 9,799
33 281 404 612 803 1,056 1,799 3,373 4,335 6,746
40 25 395 568 861 1,130 1,485 2,528 4,741 6,163 9,482
3-12 499 719 1,089 1,429 1,878 3,197 5,996 7,795 11,992
42 327 471 713 935 1,230 2,084 3,926 5,164 7,853
50 30 491 707 1,070 1,404 1,846 3,143 5,893 7,661 11,787
3-17 591 851 1,288 1,699 2,222 3,782 7,092 9,220 14,184
51 373 537 813 1,067 1,403 2,388 4,478 5,822 8,957
45 471 678 1,027 1,348 1,772 3,017 5,657 7,354 11,314
60 2,201
35 585 843 1,276 1,674 3,747 7,026 9,134 14,053
3-22 682 982 1,487 1,951 2,565 4,367 8,188 10,645 16,377
677 1,769 7,341
191 1,292 1,860 2,816 3,695 4,858 8,269 15,050 20,157 31,010
175 1,538 2,215 3,353 4,400 5,784 9,846 18,462 24,001 36,924
225 150 1,828 2,633 3,986 5,229 6,875 11,703 21,943 28,526 43,887
12-105 2,189 3,153 4,773 6,262 8,233 14,013 26,275 34,158 52,551
200 1,625 2,340 3,543 4,649 6,112 10,404 19,507 25,359 39,015
175 1,938 2,791 4,225 5,543 7,288 12,405 23,260 30,238 46,521
250
150 2,175 3,133 4,743 6,222 8,181 13,925 26,109 33,942 52,219
13-117 2,418 3,481 5,271 6,915 9,091 15,475 29,016 37,721 58,032
200 2,416 3,479 5,267 6,910 9,084 15,462 28,991 37,688 57,982
300 175 2,570 3,797 5,748 7,540 9,913 16,874 31,638 41,130 63,276
150 2,816 4,055 6,138 8,052 10,587 18,020 33,788 43,925 67,576
15-142 2,863 4,123 6,243 8,190 10,767 18,328 34,365 44,674 68,730
248 2,655 3,824 5,788 7,437 9,984 16,998
GP-11S ONLY
NOTE: Maximum pressure reduction ratio 20:1, except for GD-2000K (10:1). Minimum pressure reduction is 85% of inlet pressure.
26
Externally Piloted
GP-2000 ON/OFF - For Steam Service
External Pilot Solenoid Operated Valves
The GP-2000 On/Off option allows for This option is available as an temperature of 366F NEMA
remote shutoff of pressure reducing accessory item or may be factory IV standard, coil: class H 110v
valves. Automatic shutoff during installed on any of the GP-2000 standard. Available in normally
power failures and shutoff based on series valves. The GP-2000 On/Off open or normally closed
set points of pressure, temperature is designed for a maximum pres- configurations.
or liquid levels of process fluids. sure of 150 psig and a maximum
GP-2000K 1&2
27
Temperature Regulators
For Steam, Water, and Non-Corrosive Liquid Service
Armstrong self-actuated externally operationand suitable for a wide capillaries and varied temperature
piloted temperature regulators are variety of applications. Features ranges make installation, adjust-
compact, high performance units including flexible mounting positions ment and maintenance quick and
that are simple in design and of the sensor, interchangeable easy.
28
Temperature Regulators
OB-30/31
For Steam, Air, and Non-Corrosive Liquids
Armstrongs OB-30/31 is a direct Installing, adjusting or maintaining theres no leakage. Single
acting temperature regulator which the OB-30/31 is quick and easy composition seat for tight shutoff.
requires no external source for because interchangeable capillaries The OB-30/31 comes in 1/2", 3/4"
operation. Simple and compact, the mount in any position and dis- or 1" sizes and is available with a
unit is suitable for a wide variety of connect by simply loosening the choice of five temperature ranges
heating/cooling applications. union nut. No stem packing so and three capillary lengths.
* Standard length.
NOTES: Capillary can withstand a maximum of 72F above rated range. If desired set temperature is in temperature range overlap, select lower range.
0
L 1
2
H 3
4
H1
All dimensions and weights are approximate. Use certified print for exact dimensions. 29
OB-30/31
For Steam, Air, and Non-Corrosive Liquids
OBK-2000 1 /
34 121/2 /
14 .765 /
34 /
12 .515
G F
Standard Material: 304 Stainless Steel or Brass. Other materials available upon request.
NOTE: When inserting sensor into thermal well, for best results, it is recommended
that heat transfer medium be applied to sensor before installation.
30 All dimensions and weights are approximate. Use certified print for exact dimensions.
Temperature Regulators
OB-2000
For Steam
Armstrongs OB-2000 is a high washers. Self-actuated and requir- interchanged, offering easy
performance externally piloted ing no external energy source, the installation and maximum appli-
temperature regulator for large OB-2000 comes with pilot valve cation flexibility. Available in
capacity applications such as heat and tubing pre-assembled. Capil- sizes 1/2" through 4" with six
exchangers, steam coils, steam lary units mount in any position and temperature ranges and three
dryers, plating tanks and parts can be easily disconnected and capillary lengths.
NPT 18 - 59
10-300 50 - 97
150 lb Flg 86 - 144 +2F From * 6 1/2
Steam 7 9 1/2
10 - 185 131 - 201 Set Point
16 1/2
300 lb Flg 176 - 260
10 - 300 239 - 361
*Standard length.
NOTE: If desired set temperature is in temperature range overlap, select lower range.
G
F
41 2"
H2
41 2"
H1
21 2"
All dimensions and weights are approximate. Use certified print for exact dimensions. 31
OB-2000
For Steam
32
Temperature Regulators
OB-2000PT
For Steam Service
The OB-2000PT is a diaphragm- and the temperature of the heated range changes quick and easy.
operated externally piloted pressure/ medium is controlled using a single Available in sizes 1/2" through 4"
temperature combination regulator. seated main valve. Temperature and with a choice of four spring
It is used in applications where pilot and capillary unit disconnect, ranges, six temperature ranges
maximum pressure should be limited making repairs or temperature and three capillary lengths.
* Standard length.
All dimensions and weights are approximate. Use certified print for exact dimensions. 33
OB-2000, OB-2000PT
Capacities for Steam Service
Table 34-1. OB-2000, OB-2000PT CapacitiesSteam (lbs/hr)
Connection Size
Inlet Outlet
(psig) (psig) /"
12 /"
34 1" 11/4" 11/2" 2" 21/2" 3" 4"
10* 0-3 211 304 460 604 794 1,351 2,534 3,294 5,068
13 219 316 478 627 825 1,404 2,633 3,423 5,266
20
10 255 368 557 731 962 1,637 3,070 3,992 6,141
0 313 451 683 896 1,178 2,005 3,760 4,888 7,521
191 1,292 1,860 2,816 3,695 4,858 8,269 15,505 20,157 31,010
175 1,538 2,215 3,353 4,400 5,784 9,846 18,462 24,001 36,924
225
150 1,828 2,633 3,986 5,229 6,875 11,703 21,943 28,526 43,887
0-105 2,189 3,153 4,773 6,262 8,233 14,013 26,275 34,158 52,551
200 1,625 2,340 3,543 4,649 6,112 10,404 19,507 25,359 39,015
175 1,938 2,791 4,225 5,543 7,288 12,405 23,260 30,238 46,521
250
150 2,175 3,133 4,743 6,222 8,181 13,925 26,109 33,942 52,219
0-117 2,418 3,481 5,271 6,915 9,091 15,475 29,016 37,721 58,032
200 2,416 3,479 5,267 6,910 9,084 15,462 28,991 37,688 57,982
175 2,570 3,797 5,748 7,540 9,913 16,874 31,638 41,130 63,276
300
150 2,816 4,055 6,138 8,052 10,587 18,020 33,788 43,925 67,576
15-142 2,863 4,123 6,243 8,190 10,767 18,328 34,365 44,674 68,730
* Minimum inlet pressure for OB-2000PT is 15 psi because of the pressure pilot. NOTE: For 6" consult factory.
34
Temperature Regulators
OB-30, OB-2000, OB-2000PT
For Steam Service
Points to Remember When Installing
Drain condensate at inlet of pressure/temperature Install sensor so it is fully immersed in the fluid
regulator with inverted bucket steam trap. being heated.
Protect temperature regulating valve from dirt and If temperature well is used, apply heat transfer
scale by installing strainer with 100 mesh screen at medium to sensor before insertion into well.
inlet of valve.
Place thermometer into system in close proximity
Install shutoff valves on either side of the regulating to temperature sensor for accurate valve
valve along with a by-pass line for maintenance adjustment.
purposes.
If possible, do not elevate condensate after steam
Install vacuum breaker after the outlet of equipment trap.
and before the steam trap.
Determine pressure setting before temperature
setting (OB-2000PT only).
Figure 35-1. Typical InstallationOB-30, OB-2000
Hot Water
Minimum of 10 Inlet Outlet
Pipe Diameters T
OB-2000
Armstrong Optional
Vacuum Hot Water Tank
Strainer Breaker
Cold Water
Globe By-Pass Inlet
Valve
Armstrong
Trap
35
Application DataPressure Reducing Valves
Figure 36-1. Direct Acting Single Stage Reduction
Safety
Valve
Armstrong GD-30
Strainer
By-Pass
Globe
Valve
Armstrong
Trap
Control Pipe
Safety
(Pitch Down)
Valve
Gate
Valve
Armstrong
Strainer
GP-2000
By-Pass
Globe
Valve Minimum of 10
Pipe Diameters
from Last Valve or Fitting
Armstrong
Trap
36
Application DataPressure Reducing Valves
Figure 37-1. External Pressure Pilot Two Stage Reduction
Minimum of 10 Outlet
Pipe Diameters from PRV #1 Minimum of 20 Outlet
Minimum of 10
Pipe Diameters Pipe Diameters from PRV #2
GP-2000
GP-2000
Globe
Valve
Minimum of 10 Outlet
Pipe Diameters
Armstrong from Last Valve or Fitting
Trap
Typical External Pressure Pilot Two Stage Reduction. This system is recommended when pressure reduction
ratio exceeds capabilities of a single valve.
Control Pipe
(Pitch Down)
Gate
Valve
Armstrong
Strainer GP-2000
Armstrong
Strainer
GP-2000
Armstrong Armstrong
Trap Trap
Typical External Pressure Pilot Parallel Reduction Station. When seasonal load swings vary widely, two valves
are commonly installed in parallel with the large valve being sized for two-thirds of the total load and the small
valve handling one-third of the total load. The small valves set point is set at a slightly higher pressure than the
large valve.
37
Application DataPressure Reducing Valves
Figure 38-1. Air Loaded External Pilot Single Stage Reduction
Minimum of 10 Inlet
Pipe Diameters
Minimum of 20 Outlet
Pipe Diameters to First Turn
Air Signal
Control Pipe
Air In (Pitch Down) Safety
Valve
Gate
Armstrong Valve
Control Panel
Armstrong
Strainer
GP-2000K-1
By-Pass
Globe
Valve
Minimum of 10
Pipe Diameters
From Last Valve or Fitting
Armstrong
Trap
Typical Air Loaded External Pilot Reduction Station. Complete with remote located air loading control panel.
Minimum of 10
Pipe Diameters
Control Pipe
(Pitch Down)
Gate
Valve
Armstrong
Strainer To Vent
GP-2000R
Typical External Pilot Back Pressure Installation. Used to maintain a constant upstream pressure
in the piping system.
38
Sizing Data
Selection Formulas Formula Key
CV Value and Calculations W = Maximum flow capacity of steam, lbs/hr
P1 = Inlet pressure, psia (psig +14.7)
1. For Steam:
P2 = Outlet pressure, psia (psig + 14.7)
P W P = Pressure drop (P1P2) psi
When P2 > 1 CV=
2 2.1 P (P1 +P2) Q = Maximum flow capacity of gas SCFH
P W
*When P2 1 CV= G = Specific gravity
2 1.71 (P ) 1 T = Fluid temperature F
2. For Gas: GPM = Maximum flow capacity of liquid GPM
P1 CV = Valve flow coefficient
Q G (T+460)
When P2 > CV=
2 963 P (P1 +P2 ) * Formula applies only to piloted valves. With direct
P Q acting valves at critical flow or sonic flow, capacities
When P2 1 CV= diminish with greater differential pressure.
2 36.39 (P1 )
3. For Liquid:
CV= (GPM) G
P
Ordering Information
Table 39-1. Cv Values for Each Product
Connection Size
mm 8 10 15 20 25 32 40 50 65 80 100 125 150 200 250
Model
in /"
14 /"
38 /"
12 /"
34 1" 11/4" 11/2" 2" 21/2" 3" 4" 5" 6" 8" 10"
GD-10 1.4 1.4 1.4 2.6 5.8 5.8 5.8 43
GD-10F 1.4 1.4 1.4 2.6
GD-6/6N .35 .5 1.0 1.5
GD-20 16 28 36 68 75 108
GD-24 1.5 1.9 3 4 7 10
GD-30 & GD-50 1.3 1.5 2.5 5.6** 8.5**
GP-2000 Series 5 7.2 10.9 14.3 18.8 32 60 78 120
GP-100, GP-32 1.5 2.3 4 6.5 9 16 25 36 64 100 144 256
GP-18, GP-28, GP-1* 2.1 3.5 6.25 9.7 14 20.8 36 46 79.5 114 152 265 412
OB-30/OB-31 3.7 4.6 5.8
OB-2000/OB-2000PT 5 7.2 10.9 14.3 18.8 32 60 78 120
NOTE: *GP-1 only available to 6" Upon application only consult factory
NOTE: **GD-30 only
39
076 METRIC TABLES 4.0 12/3/98 3:02 PM Page 36
Metric Tables
Table M7-2. GD-30 and GD-50 CapacitiesSteam (kg/hr) Table M7-3. GD-30 Dimensions and Weights
Inlet Outlet Connection Size (mm) Inlet Outlet Connection Size (mm) Connection Size (mm)
Symbol
(bar) (bar) 15 20 25 40* 50* (bar) (bar) 15 20 25 40* 50* 15 20 25 40 50
1.0 .5 22 25 42 90 135 6.6 105 125 205 450 690 L (mm) 80 85 95 140 150
.9 24 28 48 98 150 4.8 125 141 235 530 825 H (mm) 191 191 191 307 307
1.4 8.3
.5 19 25 35 82 120 3.1 109 121 204 445 685 H1 (mm) 47 47 47 77 77
1.6 28 32 51 110 185 .8 50 55 90 210 320 Wt (kg) 1.9 1.9 2.0 10.1 10.4
2.0 1.0 24 27 46 95 140 8.3 130 151 250 550 845 Cv 1.3 1.5 2.5 5.6 8.5
.2 15 18 27 63 98 5.9 165 191 320 695 1,075 Also available BSPT threads. Consult factory.
10.3
2.2 45 55 85 185 280 3.8 135 160 270 580 910
2.8 1.4 36 44 72 150 235 1.0 60 75 115 255 385 Table M8-3. GD-50 Dimensions and Weights
.3 18 25 35 72 120 9.7 185 220 360 780 1,215 Connection Size (mm)
Symbol
2.8 59 65 110 245 380 8.0 195 230 390 830 1,285 15 20 25
12.4
3.4 1.4 45 52 85 185 285 4.8 175 195 335 735 1,135 L (mm) 109 109 109
.3 22 28 40 88 135 1.2 75 85 140 310 470 H (mm) 206 206 206
3.3 62 70 120 265 408 9.7 209 235 395 900 1,390 H1 (mm) 46 46 46
2.8 68 75 131 280 440 8.0 215 245 410 910 1,400 Wt (kg) 3.0 3.0 3.2
4.0 13.8
1.2 41 47 77 170 265 5.5 195 225 375 825 1,275 Cv 1.3 1.5 2.5
.4 25 33 45 100 150 1.4 95 110 175 385 590 Also available BSPT threads. Consult factory.
4.4 80 93 155 335 530 9.7 220 260 430 935 1,450
3.7 85 102 160 355 545 8.0 225 265 436 940 1,455 Table M9-3. GD-6N/GD-6 Dimensions and Weights
5.5 15.5
1.6 55 62 100 222 340 5.9 210 245 410 900 1,390 Connection Size (mm)
.5 27 35 49 105 165 1.6 115 135 225 490 760 Symbol
10 15 20 25
5.5 92 110 180 392 615 9.7 238 275 460 1,010 1,560 L (mm) 165 165 185 185
4.5 102 119 198 435 665 8.3 250 265 471 1,020 1,575 H (mm) 237 237 261 261
6.9 17.2
2.8 90 105 170 380 580 4.8 210 240 405 880 1,360 H1 (mm) 57 57 76 76
.7 31 36 60 135 215 1.7 125 145 240 520 815 E (mm) 155 155 175 175
*Available GD-30 Only NOTE: For air capacities (m3/hr) multiply steam capacities by 1.34. Maximum pressure reduction ratio 10:1. Wt (kg) 5.5 5.5 8.2 8.2
Cv .35 .5 1.0 1.5
Table M9-2. GD-6N CapacitiesSteam (kg/hr)
Inlet Outlet Connection Size (mm) Inlet Outlet Connection Size (mm)
(bar) (bar) 10 15 20 25 (bar) (bar) 10 15 20 25 Table M9-4. GD-6 CapacitiesWater (l/min)
1.0 .2-.6 8.2 11.3 23.1 34.5 2.8 11.3 16.3 33.1 49.4 P Connection Size (mm)
.9 5.4 7.7 15.4 23.1 (bar) 10 15 20 25
3.4 2.2 15.0 21.3 42.6 64.0
1.4 .35 3.0 4.2 8.3 12.9
.2-.7 9.5 13.6 26.8 40.4 .3-1.7 17.7 24.9 50.3 75.3
1.2 6.4 9.1 18.6 27.7 3.3 13.6 19.5 24.9 58.1 .7 4.2 6.0 12.1 17.8
1.7 1.0 8.6 12.7 24.9 37.6 4.1 2.8 16.8 24.0 48.5 72.6 1.0 5.3 7.2 14.8 22.0
.2-.8 10.9 15.4 30.8 46.3 .4-2.1 20.4 29.0 58.1 87.1 1.7 6.8 9.5 18.9 28.4
1.6 7.3 10.4 21.3 32.2 4.1 16.8 23.6 47.2 70.8 3.5 9.5 13.2 26.9 40.1
2.1 1.4 9.5 13.6 26.8 40.4 5.2 3.3 21.3 30.4 61.2 91.6 5.2 11.4 16.3 32.9 49.2
.2-1 12.2 17.2 34.5 52.2 .5-2.6 24.5 34.9 69.4 104.3 6.9 13.2 18.9 37.9 56.8
2.2 9.5 13.6 27.2 40.8 4.5 27.7 39.5 78.5 117.9 8.6 14.8 21.2 42.4 63.6
6.9 10.0 15.9 23.1 45.8 68.9
2.8 1.7 12.7 18.1 35.8 54.0 .7-3.4 31.3 44.5 88.9 133.4
.3-1.4 15.0 21.3 42.6 63.5 8.6 .9-4.1 38.1 54.0 108.4 162.4
10.3 1-4.1 44.9 64.4 128.4 192.8
Table M10-4. AF-10 Dimensions and Weights
NOTE: For air capacities (m3/hr) multiply steam capacities by 1.34. Maximum pressure reduction ratio 10:1.
Connection Size (mm)
Symbol
8 10 15 20 25
L (mm) 70 70 70 98 121
Table M10-2. GD-10 Dimensions and Weights Table M10-3. GD-10F Dimensions and Weights H (mm) 162 162 162 178 289
Connection Size (mm) Connection Size (mm) H1 (mm) 146 146 146 162 254
Symbol Symbol
8 10 15 20 25 8 10 15 20 Wt (kg) .9 .9 .9 .9 1.4
L (mm) 67 67 67 98 121 L (mm) 70 70 70 98
H (mm) 136 136 136 149 181 H (mm) 238 238 238 276
H1 (mm) 38 38 38 38 60 H1 (mm) 146 146 146 162
Wt (kg) .7 .7 .7 .9 1.4 Wt (kg) 1.2 1.2 2.0 2.0
Cv 1.4 1.4 1.4 2.6 5.8 Cv 1.4 1.4 1.4 2.6
076 METRIC TABLES 4.0 12/3/98 3:02 PM Page 37
Table M10-5. GD-10/GD-10F CapacitiesAir (m3/h) Table M11-3. GD-24 Dimensions and Weights
Inlet Outlet Connection Size (mm) Inlet Outlet Connection Size (mm) Connection Size (mm)
Symbol
(bar) (bar) 8,10,15 20 25*,32,40 50 (bar) (bar) 8,10,15 20 25*,32,40 50 15 20 25 32 40 50
1.0 .6 42.5 78.2 176.7 984.3 8.0 76.5 144.4 322.8 2397.0 L (mm) 83 89 102 121 152 184
1.6 42.5 73.1 166.5 1224.0 8.6 5.5 171.6 317.8 712.0 5283.6 H (mm) 197 216 245 286 343 407
2.0 1.4 45.9 86.7 195.4 1448.4 .9-4.3 200.5 373.8 834.3 6193.1 H1 (mm) 45 51 64 83 89 115
.3-1 68.0 125.7 282.1 1915.9 8.6 144.4 270.2 604.9 4488.0 Wt (kg) 1.8 2.4 3.3 4.7 8.2 14.3
2.2 47.6 88.4 197.1 1370.2 10.3 5.9 219.2 406.1 909.1 6745.6 Cv 1.5 2.0 3.0 4.0 7.0 10.0
2.8 1.7 62.9 115.5 260.0 1936.3 1-5.2 236.2 440.0 983.8 7301.5
.3-1.4 78.2 146.1 326.2 2424.2 8.6 214.1 397.6 888.7 6602.8
2.8 57.8 107.0 239.6 1776.5 12.0 6.9 251.5 469.0 1,046.7 7774.1
3.4 2.2 74.8 137.6 309.3 2303.5 1.2-6 273.6 508.1 1,133.4 8534.0
Table M12-4. GD-20 Dimensions and Weights
.3-1.7 91.8 173.3 385.7 2867.9 8.6 271.9 506.4 1,130.0 8387.8 Face-to- A H H1 Weight
13.8 Size Cv
Face (mm) (mm) (mm) (mm) (kg)
4.1 81.6 152.9 343.2 2555.1 1.4-6.9 309.3 574.3 1,282.9 9518.3
5.2 3.3 107.0 198.8 443.5 3299.7 17.2 1.7-8.6 380.6 708.6 1,582.0 11908.5 50 195 152 415 81 16 19.2
.5-2.6 129.1 237.9 533.5 3976.3 20.7 2-10.3 453.7 842.8 1,881.0 14159.0 65 270 178 550 105 28 40.0
5.5 107.0 200.5 448.6 3328.6 24.1** 2.7-12 16408.0 80 270 191 577 120 36 43.7
6.9 4.5 137.6 255.0 570.9 4343.2 29.3** 5.2-13.8 19494.0 100 308 229 637 135 68 70.0
.7-3.4 164.8 306.0 684.8 5084.7 125 380 254 839 169 75 144.0
150 400 280 908 194 108 173.0
*GD-10F not available above 25 mm.
** 50mm GD-10 valve maximum inlet pressure is 20.7 bar.
Metric Tables
Table M15-1. GP-100, GP-32 Dimensions and Weights
Connection Size (mm)
Symbol 15 20 25 32 40 50 65 80 100
L (mm) 150 155 160 190 190 220 245 290 330
H (mm) 210 210 226 24 24 27 293 343 391
H1 (mm) 64 64 67 82 82 93 100 122 144
GP-100, GP-31A Wt. (kg) 6.0 6.0 8.0 12.0 12.0 17.0
GP-32/32A Wt. (kg) 20.0 24.0 34.0 53.0
Cv 1.5 2.3 4.0 6.5 9.0 16.0 25.0 36.0 64.0
NOTE: GP-100 is 15 mm-50 mm NPT, GP-32 is 50 mm-100 mm ANSI 125 lb flanged. For sizes 125 mm-200 mm consult factory.
NOTES: For GP-100, GP-32 capacities, multiply Table M16-1 values by factor listed in Table M16-2.
For GP-31A/32A air capacities (m3/hr), multiply steam capacities for GP-31/32 by 1.34.
For GP-18A/28A/1A air capacities (m3/hr), multiply steam capacities by 1.34.
Metric Tables
Tables M18-2 and M25-2. GP-2000 and GP-2000R Dimensions and Weights
Size Face-to-Face (mm) A F H Integral H Remote H1 H2 Weights (kg)
Cv
(mm) NPT 150# 300# (mm) (mm) (mm) (mm) (mm) (mm) NPT 150# 300#
15 150 200 176 398 362 170 244 14 5.0
20 150 200 176 398 362 170 244 14 7.2
25 160 226 180 404 367 175 254 19 10.9
32 180 226 180 434 384 192 283 22 14.3
40 180 226 180 434 384 192 283 22 18.8
50 230 218 222 276 197 498 406 216 321 33 36 36 32.0
65 278 282 352 211 552 440 251 375 65 65 60.0
80 294 302 352 222 575 456 264 400 69 72 78.0
100 330 342 401 240 658 511 321 489 107 111 120.0
150 461 483 502 282 712 711 406 800 232 250 223.0
NOTE: 150 size valve standard in remote mount with 125 or 250 lb ANSI flanges.
Table M19-2. GP-11S Dimensions and Weights Table M21-2. GD-2000K Dimensions and Weights
Connection Size Size Face-to-Face (mm) H H1 A Weights (kg)
Symbol Cv
15 20 25 32 40 50 (mm) NPT 150# 300# (mm) (mm) (mm) NPT 150# 300#
A (mm) 200 200 225 225 225 276 15 150 244 74 200 13 5.0
H (mm) 412 412 422 451 451 514 20 150 244 74 200 13 7.2
H1 (mm) 143 143 149 165 165 191 25 160 251 76 226 17 10.9
Wt (kg) 20 20 26 28 28 43 32 180 282 90 226 20 14.3
Cv 5.0 7.2 10.9 14.3 18.8 32.0 40 180 282 90 226 20 18.8
NOTE: 15mm through 50mm standard is integral mount. 50 230 218 222 319 103 276 31 34 34 32.0
65 278 282 373 122 352 62 62 60.0
80 294 302 399 135 352 67 69 78.0
100 330 342 488 167 401 105 109 120.0
Tables M26-1 and M34-1. GP-2000, GP-2000K-1, K-2, GD-2000K, GP-2000R, GP-11S, OB-2000, OB-2000PT CapacitiesSteam (kg/hr)
Inlet Outlet Connection Size (mm)
(bar) (bar) 15 20 25 32 40 50 65 80 100 150*
**0.69 0-.21 96 138 209 274 360 613 1,150 1,495 2,300
.55 91 135 217 261 343 584 1,095 1,424 2,191
1.03
.21 114 163 247 325 427 727 1,364 1,773 2,728
.89 99 143 217 284 374 637 1,195 1,554 2,390
1.38 .68 115 167 253 332 437 743 1,393 1,812 2,788
.21 142 205 310 406 535 910 1,707 2,219 3,414
1.24 107 154 233 307 403 686 1,286 1,672 2,573
1.72
.21-.34 153 222 335 440 579 986 2,080 2,889 4,446
1.58 114 164 248 327 430 731 1,372 1,784 2,746
2.07
.21-.48 173 249 378 496 652 1,109 2,080 2,889 4,446
2.27 127 183 277 364 479 816 1,530 1,966 3,060
2.75 1.7 179 258 391 512 673 1,147 2,151 2,796 4,302
.21-.83 212 305 462 607 798 1,811 2,546 3,536 5,441
2.89 148 213 323 424 558 945 1,781 2,343 3,563
3.44 2.06 222 320 485 637 837 1,426 2,673 3,475 5,348
.21-1.17 251 362 547 717 944 1,606 3,011 4,183 6,435
3.5 169 243 369 484 636 1,083 2,031 2,641 4,064
3.1 213 307 465 611 803 1,368 2,566 3,336 5,133
4.13
2.4 265 382 579 759 998 1,700 3,188 4,144 6,376
.21-1.5 290 417 631 829 1,089 1,854 3,468 4,830 7,430
4.3 213 307 465 610 798 1,366 2,562 3,330 5,124
3.7 268 387 586 769 1,011 1,721 3,227 4,196 6,455
5.17
3.1 318 459 695 912 1,199 2,041 3,827 4,975 7,654
.27-2.1 348 501 758 995 1,308 2,226 4,175 5,799 8,877
5.8 269 388 588 772 1,015 1,015 1,728 4,214 6,487
5.1 340 490 742 973 1,280 2,179 4,086 5,312 8,172
6.89
24.12
13.78 1,404 2,021 3,060 4,014 5,278 8,985
1.24-11.02 1,511 2,176 3,295 4,323 5,683 9,673
17.08 1,679 2,418 3,661 4,803 6,314 10,747
29.28 15.50 1,755 2,528 3,827 5,021 6,600 11,235
1.52-13.4 1,822 2,624 3,972 5,211 6,852 11,663
*150 mm valve standard with 125 lb or 250 lb ANSI flange connections and cast iron bodies.
** .69 bar inlet only applies to OB-2000 valve.
Maximum pressure reduction is 20:1 except for GD-2000K (10:1).
Minimum pressure reduction is 85% of inlet pressure.
076 METRIC TABLES 4.0 12/3/98 3:02 PM Page 42
Metric Tables
Table M29-3. OB-30/31 Dimensions and Weights
Size L H H1 T K R
Weights (kg) Cv
(mm) (mm) (mm) (mm) (mm) (mm) (mm)
15 80 315 130 10 200 15 2.8 3.7
20 85 315 130 10 200 15 2.8 4.6
25 95 315 130 10 200 15 3.0 5.8
Table M30-1. OB-30 CapacitiesSteam (kg/hr) Table M30-2. OB-30/31 CapacitiesWater (l/min)
Inlet Outlet Connection Size (mm) Inlet Outlet Connection Size (mm) P Connection Size (mm)
(bar) (bar) 15 20 25 (bar) (bar) 15 20 25 (bar) 15 20 25
Cv Factors 3.7 4.6 5.8 Cv Factors 3.7 4.6 5.8 .35 30 38 47
.20 30 38 48 3.45 132 164 206 .70 45 55 70
.35 .14 37 45 58 4.0 2.76 180 223 281 1.00 55 67 83
0 46 57 72 0-1.5 229 285 360 1.40 63 78 100
.55 34 43 54 4.0 141 175 221 1.80 70 83 107
.41 47 59 75 3.45 149 193 302 2.00 77 97 120
.7 4.83
.28 57 70 89 2.76 228 284 358 3.50 100 127 157
0 70 87 110 0-1.9 260 323 408 5.20 123 150 187
.83 46 57 72 4.83 150 186 280 7.00 143 175 217
.62 63 78 99 4.0 205 255 322 8.70 160 197 248
1.0 5.52
.41 75 93 118 3.45 244 304 383 10.40 175 217 267
0-.35 91 113 143 0-2.2 291 361 456
1.0 63 79 99 5.52 157 196 247
.7 82 107 135 4.83 217 315 340
1.38
.35 100 125 158 6.0 4.0 259 322 406
0-.14 106 132 167 3.45 290 361 455
1.38 68 85 106 0-2.6 321 400 504
1.0 93 115 145 6.0 165 205 259
1.72
.7 110 136 172 5.52 228 284 358
0-.35 122 151 191 6.9 4.83 273 340 428
1.72 72 90 114 4.0 307 382 482
2.0 1.0 117 146 185 0-2.9 353 438 552
0-.48 137 170 215 7.59 222 276 349
2.0 111 138 175 6.9 281 350 441
2.76 1.38 149 185 234 8.62 5.52 363 451 568
0-.83 168 209 263 4.83 392 488 615
2.76 122 151 191 0-3.8 429 534 673
3.45 2.0 174 205 259 8.97 278 345 435
0-1.2 199 247 311 8.28 335 416 525
10.0
NOTE: Where it is not possible to calculate pressure drop, 6.9 417 519 654
35%-40% of gauge supply pressure can be used as 0-4.3 506 629 793
a reasonable approximation.
076 METRIC TABLES 4.0 12/3/98 3:02 PM Page 43
Other Products
Flo-Rite-Temp Radiator Products
Armstrongs tankless instan- Thermostatic radiator valves,
taneous steam water heater traps, replacement capsules
provides up to 8,700 gallons and air vents for industrial,
per hour instantly. It elim- commercial and residential
inates troublesome storage applications. Ask for catalog
tanks and allows you to heat AY-201.
water as you need itwith
lower installed costs, less
maintenance and saved
space.
Armstrong-Yoshitake, Inc.
221 Armstrong Blvd., P.O. Box 408, Three Rivers, Michigan 49093 - USA Ph: (616) 278-6610, Fax: (616) 273-8656
Steam Traps \ Humidifiers \ Steam Coils \ Valves\ Water Heaters \ Air Vents \ Pumping Traps
Catalog AY-110-H 10M 8/98 www.armstrong-intl.com Printed in U.S.A.