Вы находитесь на странице: 1из 42

ETERNUS

ETERNUS DX 60 S2, DX80 S2, DX90 S2 Disk Storage Systems


System Configuration Guide February 2013, 6th edition
CONTENTS

[Specification]
(1) ETERNUS DX60 S2 1
(2) ETERNUS DX80 S2 2
(3) ETERNUS DX90 S2 3
(4) Supported RAID 4

[Outline]
(1) View 5
(2) Product Diagrams 7

[System configuration tree diagram]


(1) ETERNUS DX60 S2 (Dual-controller type) 9
(2) ETERNUS DX60 S2 (Single-controller type) 11
(3) ETERNUS DX80 S2 (Dual-controller type) 14
(4) ETERNUS DX80 S2 (Single-controller type) 17
(5) ETERNUS DX90 S2 (Dual-controller type) 20
(6) ETERNUS DX90 S2 (Single-controller type) 23
(7) Options 26
(8) Cables 39
(9) Rack 40
(10) ETERNUS Multipath Driver 41

Product ID/Descriptions Meaning of each circle ()


Each product has "Product Description", "ProductID" => Only one selection can be made
and "Brief Remarks" as follows. =>Multiple selections are possible.
(There may be some restriction)
Ex) Product name

Drive enclosure
Select only

connections
- Rackmount type 2U
Concurrent

permitted

ETLDE2AU

Product ID Brief Remarks

Copyright 2013 FUJITSU LIMITED


ETERNUS DX60 S2, DX80 S2, DX90 S2
(1) ETERNUS DX60 S2 Specification

Product name ETERNUS DX60 S2


2.5" MODEL 3.5" MODEL
SINGLE DUAL SINGLE DUAL
CONTROLLER CONTROLLER CONTROLLER CONTROLLER
Supported RAID levels 0, 1, 1+0, 5, 5+0, 6
Physical capacity *2 Max. 24.0TB Max. 72.0TB
Storage Capacity *1
Logical capacity *3 Max. 17.8TB Max. 53.4TB
Number of controllers 1 2 1 2
Fibre Channel (Max. 4Gbit/s)
Host Interfaces iSCSI (Max. 1Gbit/s)
SAS (Max. 3Gbit/s)
Number of host interfaces 2 4 2 4
Number of connectable hosts 32, 64 (2, 4 for SAS connection)
Cache memory capacity 1GB 2GB 1GB 2GB
Number of drives 2 - 24
3.5" Capacity (rotation speed) - 600GB, 450GB, 300GB (15,000rpm)
SAS disk drive Drive interface - SAS (Max. 3Gbit/s)
3.5" nearline Capacity (rotation speed) - 3TB, 2TB, 1TB (7,200rpm)
SAS disk drive Drive interface - SAS (Max. 3Gbit/s)
Capacity -
3.5" SSD
Drive interface -
Disk Drives
2.5" 900GB, 600GB,450GB,300GB(10,000rpm)
Capacity (rotation speed) -
SAS disk drive Drive interface SAS (Max. 3Gbit/s) -
2.5" nearline Capacity (rotation speed) 1TB (7,200rpm) -
SAS disk drive Drive interface SAS (Max. 3Gbit/s) -
Capacity -
2.5" SSD
Drive interface -
Controller Enclosure 483 650 88 mm (2U) 483 650 88 mm (2U)
Dimensions (W x D x H)
Drive Enclosure - 483 650 88 mm (2U)
Maximum Weight Controller Enclosure 35 kg 35 kg
(per one Enclosure) Drive Enclosure - 35 kg
Voltage AC 100 - 120 V / AC 200 - 240 V
Power Phase Single
Frequency 50 Hz / 60 Hz
Maximum Power Controller Enclosure 510W (520VA) [1,840kJ/h] 440W (450VA) [1,590kJ/h]
AC100-120V
Consumption Drive Enclosure - 370W (380VA) [1,340kJ/h]
[Maximum Heat Controller Enclosure 500W (510VA) [1,800kJ/h] 430W (440VA) [1,550kJ/h]
AC200-240V
Generation] Drive Enclosure - 370W (380VA) [1,340kJ/h]
Temperature 10 - 40 C (Operating), 0 - 50 C (Non-operating)
Environmental Conditions
Humidity 20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
*1: Storage capacity depends on which HDDs are mounted.
*2: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.
*3: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.
User area capacity differs depending on the environment.

1
ETERNUS DX60 S2, DX80 S2, DX90 S2

(2) ETERNUS DX80 S2 Specification

Product name ETERNUS DX80 S2


2.5" MODEL *1 3.5" MODEL
SINGLE DUAL SINGLE DUAL
CONTROLLER CONTROLLER CONTROLLER CONTROLLER
Supported RAID levels 0, 1, 1+0, 5, 5+0, 6
Physical capacity *3 Max. 360.0TB
Storage Capacity *2
Logical capacity *4 Max. 267.0TB
Number of controllers 1 2 1 2
Fibre Channel (Max. 16Gbit/s)
iSCSI (Max. 1Gbit/s)
Host Interfaces iSCSI (Max. 10Gbit/s)
SAS (Max. 6Gbit/s)
FCoE (Max. 10Gbit/s)
Number of host interfaces 2/4 4/8 2/4 4/8
Number of connectable hosts Max. 1,024
Cache memory capacity 2GB 4GB 2GB 4GB
Number of drives 2-120
3.5" Capacity (rotation speed) 600GB, 450GB, 300GB (15,000rpm)
SAS disk drive Drive interface SAS (Max. 6Gbit/s)
3.5" nearline Capacity (rotation speed) 3TB, 2TB, 1TB (7,200rpm)
SAS disk drive Drive interface SAS (Max. 6Gbit/s)
Capacity 800GB, 400GB, 200GB, 100GB
3.5" SSD
Drive interface SAS (Max. 6Gbit/s)
Disk Drives
2.5" Capacity (rotation speed) 900GB, 600GB,450GB,300GB(10,000rpm)
SAS disk drive Drive interface SAS (Max. 6Gbit/s)
2.5" nearline Capacity (rotation speed) 1TB (7,200rpm)
SAS disk drive Drive interface SAS (Max. 6Gbit/s)
Capacity 800GB, 400GB, 200GB, 100GB
2.5" SSD
Drive interface SAS (Max. 6Gbit/s)
Controller Enclosure 482 645 88 mm (2U) 482 670 88 mm (2U)
Dimensions (W x D x H)
Drive Enclosure 482 540 88 mm (2U) 482 555 88 mm (2U)
Maximum Weight Controller Enclosure 35 kg 35 kg
(per one Enclosure) Drive Enclosure 35 kg 35 kg
Voltage AC 100 - 120 V / AC 200 - 240 V
Power Phase Single
Frequency 50 Hz / 60 Hz
Maximum Controller Enclosure 630W (640VA) [2,300kJ/h] 620W (630VA) [2,300kJ/h]
Power AC100 - 120V Drive Enclosure 570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]
Consumption Maximum configuration 5,570W (5,670VA) [20,300kJ/h]
[Maximum Controller Enclosure 630W (640VA) [2,300kJ/h] 610W (620VA) [2,200kJ/h]
Heat AC200 - 240V Drive Enclosure 570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]
Generation] Maximum configuration 5,560W (5,660VA) [20,200kJ/h]
Temperature 10 40 C (Operating), 0 - 50 C (Non-operating)
Environmental Conditions
Humidity 20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
*1: 2.5" base unit items are based on configuration with 2.5" drive enclosures only.
*2: Storage capacity depends on which HDDs are mounted.
*3: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.
*4: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.
User area capacity differs depending on the environment.
*5: Mixtures of 2.5" and 3.5" drives are supported by adding both 2.5" and 3.5" drive enclosures.

2
ETERNUS DX60 S2, DX80 S2, DX90 S2

(3) ETERNUS DX90 S2 Specification


Product name ETERNUS DX90 S2
2.5" MODEL *1 3.5" MODEL
SINGLE DUAL SINGLE DUAL
CONTROLLER CONTROLLER CONTROLLER CONTROLLER
Supported RAID levels 0, 1, 1+0, 5, 5+0, 6
Physical capacity *3 Max. 360.0TB
Storage Capacity *2
Logical capacity *4 Max. 267.0TB
Number of controllers 1 2 1 2
Fibre Channel (Max. 16Gbit/s)
iSCSI (Max. 1Gbit/s)
Host Interfaces iSCSI (Max. 10Gbit/s)
SAS (Max. 6Gbit/s)
FCoE (Max. 10Gbit/s)
Number of host interfaces 2/4 4/8 2/4 4/8
Number of connectable hosts Max. 1,024
Cache memory capacity 4GB 8GB 4GB 8GB
Number of drives 2-240 2-120
3.5" Capacity (rotation speed) 600GB, 450GB, 300GB (15,000rpm)
SAS disk drive Drive interface SAS (Max. 6Gbit/s)
3.5" nearline Capacity (rotation speed) 3TB, 2TB, 1TB (7,200rpm)
SAS disk drive Drive interface SAS (Max. 6Gbit/s)
Capacity 800GB, 400GB, 200GB, 100GB
3.5" SSD
Drive interface SAS (Max. 6Gbit/s)
Disk Drives
2.5" Capacity (rotation speed) 900GB, 600GB,450GB,300GB(10,000rpm)
SAS disk drive Drive interface SAS (Max. 6Gbit/s)
2.5" nearline Capacity (rotation speed) 1TB (7,200rpm)
SAS disk drive Drive interface SAS (Max. 6Gbit/s)
Capacity 800GB, 400GB, 200GB, 100GB
2.5" SSD
Drive interface SAS (Max. 6Gbit/s)
Controller Enclosure 482 645 88 mm(2U) 482 670 88 mm(2U)
Dimensions (W x D x H)
Drive Enclosure 482 540 88 mm(2U) 482 555 88 mm(2U)
Maximum Weight Controller Enclosure 35 kg 35 kg
(per one Enclosure) Drive Enclosure 35 kg 35 kg
Voltage AC 100 - 120 V / AC 200 - 240 V
Power Phase Single
Frequency 50 Hz / 60 Hz
Maximum Controller Enclosure 630W (640VA) [2,300kJ/h] 620W (630VA) [2,300kJ/h]
Power AC100 - 120V Drive Enclosure 570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]
Consumption Maximum configuration 5,760W (5,860VA) [21,200kJ/h]
[Maximum Controller Enclosure 630W (640VA) [2,300kJ/h] 610W (620VA) [2,200kJ/h]
Heat AC200 - 240V Drive Enclosure 570W (580VA) [2,100kJ/h] 550W (560VA) [2,000kJ/h]
Generation] Maximum configuration 5,760W (5,860VA) [21,200kJ/h]
Temperature 10 - 40 C (Operating), 0 - 50 C (Non-operating)
Environmental Conditions
Humidity 20 - 80 %RH (Operating), 8 - 80 %RH (Non-operating)
*1: 2.5" base unit items are based on configuration with 2.5" drive enclosures only.
*2: Storage capacity depends on which HDDs are mounted.
*3: The physical capacity value was calculated as 1 KByte = 1,000 Bytes.
*4: The logical capacity value was calculated as 1 KByte = 1,024 Bytes when formatted as RAID5.
User area capacity differs depending on the environment.
*5: Mixtures of 2.5" and 3.5" drives are supported by adding both 2.5" and 3.5" drive enclosures.

3
ETERNUS DX60 S2, DX80 S2, DX90 S2
(4) Supported RAID

The ETERNUS DX60 S2/DX80 S2/DX90 S2 support the following RAID levels.
Use of RAID0 is not recommended because it is not redundant.
For RAID0 configurations, data may be lost due to disk drive failure.

Supported number disk drives Recommended number disk drives


ETERNUS DX80 S2
RAID level ETERNUS DX60 S2
ETERNUS DX90 S2
RAID0 2 - 16 2 - 16 *1
RAID1 2 2 2 (1Data + 1Mirror)
RAID1+0 4 - 24 4 - 32 4 (2Data + 2Mirror)
6 (3Data + 3Mirror)
8 (4Data + 4Mirror)
10 (5Data + 5Mirror)
RAID5 3 - 16 3 - 16 3 (2Data + 1Parity)
4 (3Data + 1Parity)
5 (4Data + 1Parity)
6 (5Data + 1Parity)
RAID5+0 (3 - 12) x 2 (3 - 16) x 2 3 (2Data + 1Parity) x 2
4 (3Data + 1Parity) x 2
5 (4Data + 1Parity) x 2
6 (5Data + 1Parity) x 2
RAID6 5 - 16 5 - 16 5 (3Data + 2Parity)
6 (4Data + 2Parity)
7 (5Data + 2Parity)
*1: Use of RAID0 is not recommended because it is not redundant.

4
ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX60 S2 View

(1) ETERNUS DX60 S2 View

- Base unit

Front Cover

Base unit front view Base unit front view


(3.5" type) (2.5" type)

Controller (Standard)
(Additional Controller (Option))

Host Interface (Standard)

AC power cable (200V)(Standard)

LAN port

Drive interface (OUT) port


Power Supply Unit (Standard)

Base unit rear view

- Drive Enclosure

Front Cover

Drive Enclosure front view


(3.5" type)

Drive interface (OUT) port


Drive interface (IN) port

AC power cable (200V)(Standard)

Power Supply Unit (Standard)

Drive Enclosure rear view

5
ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX80 S2, DX90 S2 View

(2) ETERNUS DX80 S2, DX90 S2 View

- Base unit (Controller Enclosure)

3.5" disk 2.5" disk

Base unit front view Base unit front view


(3.5" type) (2.5" type)

Controller (Standard)
(Additional Controller (Option))

Host Interface (Standard)

AC power cable (200V)(Standard)

LAN port

Drive interface (OUT) port


Power Supply Unit (Standard)

Base unit rear view

- Drive Enclosure

3.5" disk 2.5" disk

Drive Enclosure front view Drive Enclosure front view


(3.5" type) (2.5" type)

Drive interface (OUT) port


Drive interface (IN) port

AC power cable (200V)(Standard)

Power Supply Unit (Standard)

Drive Enclosure rear view

6
ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX60 S2 Product Diagrams

Server
LAN cable (category 5e) 5m x 2
HBA (Host Bus Adaptor): (Setup node/Management LAN
FC / SAS / LAN card Connection)(Option)

Host Interface cable (Option)


FC cable (5m) x 2
LAN cable (category 5e)(5m) x2
SAS cable (1.5m) x2

ETERNUS DX60 S2 base unit


Controller Enclosure Controller Enclosure
(Standard) (Standard/Option)

Host interface Host interface


(Standard) (Standard/Option)

AC power cable 200V 4m x2


Disk Drive (Option) (Max, 12/24 drives can be installed *1)

...... Power distribution unit (AC200V) (Option)

SAS cable (0.75m) x2


(Attached to Drive Enclosure)
Extension cable (Option)
SAS cable (3m or 6m) x2
(Order when standard cable is too short)

3.5" Drive Enclosure (Option) *2

Disk Drive (Option) (Max, 12 drives can be installed) AC power cable 200V 4m x2

...... Power distribution unit (AC200V)


(Option) (Share with base unit)

*1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.
(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)
*2: The following table shows the type and number of drive enclosures that can be installed in DX60 S2.
Drive Enclosure
Base unit
3.5" type 2.5" type
3.5" type Max. 1 Not supported
ETERNUS DX60 S2
2.5" type Not supported Not supported

7
ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX80 S2, DX90 S2 Product Diagrams

Server

LAN cable (category 5e) 5m x 2


HBA (Host Bus Adaptor): (Setup node/Management LAN
FC / SAS / LAN / FCoE card Connection)(Option)
(Remote monitoring function requires additional LAN

Host Interface Option


(At least one set of Host interfaces is mandatory for
single-controller model. And two of the same host
interface sets are mandatory for dual-controller.)
- Fibre Channel
- SAS
- iSCSI (1Gbit/s)
- iSCSI (10Gbit/s)
- FCoE

ETERNUS DX80 S2, DX90 S2 base unit


Controller Enclosure Controller Enclosure AC power cable 200V 4m x2
(One option must be chosen) (One option must be
IEC cable x2 (Option)
chosen)
Disk Drive (Option) (Max, 12/24 drives can be installed *1)

Power distribution unit (AC200V)


...... (Option)

Thin Provisioning Feature (Option)


(Max. one license can be installed)

SAS cable (0.75m) x2


(Attached to Drive Enclosure)

Extension cable (Option)


SAS cable (3m or 6m) x2
(Order when standard cable is too short)

Drive Enclosure (Option)


Total four/nine DE (2.5"/3.5") can be installed. *2
AC power cable 200V 4m x2
Disk Drive (Option) (Max, 12/24 drives can be installed *1) IEC cable x2 (Option)

...... Power distribution unit (AC200V)


(Option) (Share with base unit)

*1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.
(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)
*2: Mixture of 3.5" type drive enclosures and 2.5" type drive enclosures enables
mixture of 3.5" drives and 2.5" drives in the same machine.
Up to 120 drives can be installed in a single ETERNUS DX80 S2.
Up to 240 drives can be installed in a single ETERNUS DX90 S2.
The following table shows the type and number of drive enclosures that can be installed in DX80 S2/DX90 S2.
Drive Enclosure
Base unit
3.5" type 2.5" type
3.5" type Max. 9 Max. 4
ETERNUS DX80 S2
2.5" type Max. 9 Max. 4
3.5" type Max. 9 Max. 9
ETERNUS DX90 S2
2.5" type Max. 9 Max. 9
8
ETERNUS DX60 S2, DX80 S2, DX90 S2
(1) ETERNUS DX60 S2 (dual-controller type)

i) ETERNUS DX60 S2 base unit (Dual controller type, Fibre Channel connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 4Gbps, FC, dual-controller) (3.5inch, 4Gbps, FC, dual-controller)
Product ID ET062DCFU ET062DDFU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (FC4Gbit/s x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

ii) ETERNUS DX60 S2 base unit (Dual controller type, SAS connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 3Gbps, SAS, dual-controller) (3.5inch, 3Gbps, SAS, dual-controller)
Product ID ET062DCSU ET062DDSU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (SAS x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

9
ETERNUS DX60 S2, DX80 S2, DX90 S2
(1) ETERNUS DX60 S2 (dual-controller type)

iii) ETERNUS DX60 S2 Base Unit (Dual controller type, iSCSI connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 1Gbps, iSCSI, dual- (3.5inch, 1Gbps, iSCSI, dual-
Product ID ET062DCLU ET062DDLU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (iSCSI x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

10
ETERNUS DX60 S2, DX80 S2, DX90 S2
(2) ETERNUS DX60 S2 (single-controller type)

i) ETERNUS DX60 S2 base unit (Single controller type, Fibre Channel connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 4Gbps, FC, Single-controller) (3.5inch, 4Gbps, FC, Single-controller)
Product ID ET062SCFU ET062SDFU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (FC4Gbit/s x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

- Additional Controller module (ETERNUS DX60 S2 Fibre Channel connection)


ETERNUS DX60 S2 (2.5")

Additional controller module for DX60 S2 (2.5inch, 4Gbps, FC)


[Field] ETEEC6CF-L
- Controller x1 (with FC 4Gbps 2port)
- Cache memory (1GB x1)

ETERNUS DX60 S2 (3.5")

Additional controller module for DX60 S2 (3.5inch, 4Gbps, FC)


[Field] ETEEC6DF-L
- Controller x1 (with FC 4Gbps 2port)
- Cache memory (1GB x1)

11
ETERNUS DX60 S2, DX80 S2, DX90 S2
(2) ETERNUS DX60 S2 (single-controller type)

ii) ETERNUS DX60 S2 base unit (Single controller type, SAS connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 3Gbps, SAS, Single- (3.5inch, 3Gbps, SAS, Single-
Product ID ET062SCSU ET062SDSU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (SAS x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

- Additional Controller module (ETERNUS DX60 S2 SAS connection)


ETERNUS DX60 S2 (2.5")

Additional controller module for DX60 S2 (2.5inch, 3Gbps, SAS)


[Field] ETEEC6CS-L
- Controller x1 (with SAS 3Gbps 2port)
- Cache memory (1GB x1)

ETERNUS DX60 S2 (3.5")

Additional controller module for DX60 S2 (3.5inch, 3Gbps, SAS)


[Field] ETEEC6DS-L
- Controller x1 (with SAS 3Gbps 2port)
- Cache memory (1GB x1)

12
ETERNUS DX60 S2, DX80 S2, DX90 S2
(2) ETERNUS DX60 S2 (single-controller type)

iii) ETERNUS DX60 S2 Base Unit (Single controller type, iSCSI connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 1Gbps, iSCSI, Single- (3.5inch, 1Gbps, iSCSI, Single-
Product ID ET062SCLU ET062SDLU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (iSCSI x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

- Additional Controller module (ETERNUS DX60 S2 iSCSI connection)


ETERNUS DX60 S2 (2.5")

Additional controller module for DX60 S2 (2.5inch, 1Gbps, iSCSI)


[Field] ETEEC6CL-L
- Controller x1 (with iSCSI 1Gbps 2port)
- Cache memory (1GB x1)

ETERNUS DX60 S2 (3.5")

Additional controller module for DX60 S2 (3.5inch, 1Gbps, iSCSI)


[Field] ETEEC6DL-L
- Controller x1 (with iSCSI 1Gbps 2port)
- Cache memory (1GB x1)

13
ETERNUS DX60 S2, DX80 S2, DX90 S2
(3) ETERNUS DX80 S2 (dual-controller type)

- ETERNUS DX80 S2 base unit (dual-controller type)


ETERNUS DX80 S2 ETERNUS DX80 S2
Product name
(2.5inch, dual-controller type) (3.5inch, dual-controller type)
Product ID ET082DCU ET082DDU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller x2
- Cache memory (2G) x2
- Power Supply Unit x2
- Two sets of Host Interfaces are mandatory.
- Up to 24 drives can be installed in 2.5" type.
Notes Up to 12 drives can be installed in 3.5" type.
- At least two disk drives are mandatory. Up to 120 drives can be added.
- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

14
ETERNUS DX60 S2, DX80 S2, DX90 S2
(3) ETERNUS DX80 S2 (dual-controller type)

- Host interface (ETERNUS DX80 S2)


ETERNUS DX80 S2 Two host interface options are mandatory. (Four host ports are mandatory.)
Up to four options can be installed. (Up to eight ports can be installed.)
Either two or four options should be same type. (Either four or eight ports should be same type.)
Mixing different interfaces is supported.

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Factory] ETEHH12
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)


[Factory] ETEHF12
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)


[Field] ETEHF12-L
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (SAS, 2port)


[Factory] ETEHS12
- Host interface module (SAS) x1

Host interface for DX80 S2/DX90 S2 (SAS, 2port)


[Field] ETEHS12-L
- Host interface module (SAS) x1

Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)


[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1

Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)


[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1

15
ETERNUS DX60 S2, DX80 S2, DX90 S2
(3) ETERNUS DX80 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1

[Factory]: Factory mount option


[Field]: Field upgrade option

16
ETERNUS DX60 S2, DX80 S2, DX90 S2
(4) ETERNUS DX80 S2 (Single-controller type)

- ETERNUS DX80 S2 base unit (single-controller type)


ETERNUS DX80 S2 ETERNUS DX80 S2
Product name
(2.5inch, single-controller type) (3.5inch, single-controller type)
Product ID ET082SCU ET082SDU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller x1
- Cache memory (2G) x1
- Power Supply Unit x2
- One Host Interface set is mandatory.
No additional controller can be installed in the base unit of the single controller
model at the time of shipment.
Notes - Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.
- At least two disk drives are mandatory. Up to 120 drives can be added.
- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

'- Additional Controller module (ETERNUS DX80 S2)


ETERNUS DX80 S2 One Controller module can be added on single-controller type.

Additional controller module for DX80 S2


[Field] ETEAC8A-L
- Controller x1
- Cache memory (2GB x1)

17
ETERNUS DX60 S2, DX80 S2, DX90 S2
(4) ETERNUS DX80 S2 (Single-controller type)

- Host interface (ETERNUS DX80 S2)


ETERNUS DX80 S2 One host interface option is mandatory. (Two host ports are mandatory.)
Up to two options can be installed for single CM model. (Up to four ports can be installed.)
Mixing different interfaces is supported for single CM model.
Up to four options can be installed for dual CM model. (Up to eight ports can be installed.)
Either two or four options should be same type for dual CM model.
(Either four or eight ports should be same type for dual CM model.)

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Factory] ETEHH12
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)


[Factory] ETEHF12
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)


[Field] ETEHF12-L
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (SAS, 2port)


[Factory] ETEHS12
- Host interface module (SAS) x1

Host interface for DX80 S2/DX90 S2 (SAS, 2port)


[Field] ETEHS12-L
- Host interface module (SAS) x1

Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)


[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1

Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)


[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G)18
x1
ETERNUS DX60 S2, DX80 S2, DX90 S2
(4) ETERNUS DX80 S2 (Single-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1

[Factory]: Factory mount option


[Field]: Field upgrade option

19
ETERNUS DX60 S2, DX80 S2, DX90 S2
(5) ETERNUS DX90 S2 (dual-controller type)

- ETERNUS DX90 S2 base unit (dual-controller type)


ETERNUS DX90 S2 ETERNUS DX90 S2
Product name
(2.5inch, dual-controller type) (3.5inch, dual-controller type)
Product ID ET092DCU ET092DDU
Rackmount type (2U), AC200V
Enclosure x1
Configuration - Controller x2
- Cache memory (4GB) x2
- Power Supply Unit x2
- Two sets of the same Host Interface are mandatory.
Up to 24 drives can be installed in 2.5" type.
Up to 12 drives can be installed in 3.5" type.
Notes
- At least two disk drives are mandatory. Up to 240 2.5" drives can be added.
Up to 120 3.5" drives can be added.
- Up to nine Drive Enclosures(2.5"/3.5") can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

20
ETERNUS DX60 S2, DX80 S2, DX90 S2
(5) ETERNUS DX90 S2 (dual-controller type)

- Host interface (ETERNUS DX90 S2)


ETERNUS DX90 S2 Two host ports are mandatory. (Four ports host interface are mandatory.)
Up to four options can be installed. (Up to eight ports can be installed.)
Either two or four options should be same type. (Either four or eight ports should be same type.)
Mixing different interfaces is supported.

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Factory] ETEHH12
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)


[Factory] ETEHF12
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)


[Field] ETEHF12-L
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (SAS, 2port)


[Factory] ETEHS12
- Host interface module (SAS) x1

Host interface for DX80 S2/DX90 S2 (SAS, 2port)


[Field] ETEHS12-L
- Host interface module (SAS) x1

Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)


[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1

Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)


[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1

21
ETERNUS DX60 S2, DX80 S2, DX90 S2
(5) ETERNUS DX90 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1

[Factory]: Factory mount option


[Field]: Field upgrade option

22
ETERNUS DX60 S2, DX80 S2, DX90 S2
(6) ETERNUS DX90 S2 (single-controller type)

- ETERNUS DX90 S2 base unit (single-controller type)


ETERNUS DX90 S2 ETERNUS DX90 S2
Product name
(2.5inch, single-controller type) (3.5inch, single-controller type)
Product ID ET092SCU ET092SDU
Rackmount type (2U), AC200V
Enclosure x1
Configuration - Controller x1
- Cache memory (4GB) x1
- Power Supply Unit x2
- One set of the same Host Interfaces are mandatory.
No additional controller can be installed in the base unit of the single controller
model at the time of shipment.
- Up to 24 drives can be installed in 2.5" type.
Notes
Up to 12 drives can be installed in 3.5" type.
- At least two disk drives are mandatory. Up to 240 2.5" drives can be added.
Up to 120 3.5" drives can be added.
- Up to nine 3.5" or four 2.5" Drive Enclosures can be added.

- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1

- Additional Controller module (ETERNUS DX90 S2)


ETERNUS DX90 S2 One Controller module can be added on single-controller type.

Additional controller module for DX90 S2


[Field] ETEAC9A-L
- Controller x1
- Cache memory (4GB x1)

23
ETERNUS DX60 S2, DX80 S2, DX90 S2
(6) ETERNUS DX90 S2 (single-controller type)

- Host interface (ETERNUS DX90 S2)


ETERNUS DX90 S2 One host interface option is mandatory. (Two host ports are mandatory.)
Up to two options can be installed for single CM model. (Up to four ports can be installed.)
Mixing different interfaces is supported for single CM model.
Up to four options can be installed for dual CM model. (Up to eight ports can be installed.)
Either two or four options should be same type for dual CM model.
(Either four or eight ports should be same type for dual CM model.)

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Factory] ETEHH12
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 16G, 2port)


[Field] ETEHH12-L
- Host interface module (FC 16G) x1
- SFP+ (16Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)


[Factory] ETEHF12
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (FC 8G, 2port)


[Field] ETEHF12-L
- Host interface module (FC 8G) x1
- SFP+ (8Gbit/s) module x2

Host interface for DX80 S2/DX90 S2 (SAS, 2port)


[Factory] ETEHS12
- Host interface module (SAS) x1

Host interface for DX80 S2/DX90 S2 (SAS, 2port)


[Field] ETEHS12-L
- Host interface module (SAS) x1

Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)


[Factory] ETEHL12
- Host interface module (iSCSI 1G) x1

Host interface for DX80 S2/DX90 S2 (1Gbit/s, iSCSI, 2port)


[Field] ETEHL12-L
- Host interface module (iSCSI 1G) x1

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1

Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G)24
x1
ETERNUS DX60 S2, DX80 S2, DX90 S2
(6) ETERNUS DX90 S2 (single-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1

Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1

[Factory]: Factory mount option


[Field]: Field upgrade option

25
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options

- Disk drive option (2.5inch disk drive)


* 2.5inch drives are installed in the 2.5inch type controller enclosure

ETERNUS DX60 S2

Disk drive
2.5inch disk drive
* Mandatory option
* Up to 24 drives can be installed in a 2.5inch base unit.
2.5inch 10krpm SAS disk drive
Factory mount options
Product name Product ID
Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX60 S2 ETED3MB
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX60 S2 ETED3PB
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX60 S2 ETED3DB
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX60 S2 ETED3SB
Disk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2 ETED3HB
Disk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX60 S2 ETED4MB
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX60 S2 ETED4PB
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX60 S2 ETED4DB
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX60 S2 ETED4SB
Disk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2 ETED4HB
Disk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX60 S2 ETED6MB
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX60 S2 ETED6PB
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX60 S2 ETED6DB
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX60 S2 ETED6SB
Disk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2 ETED6HB
Disk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX60 S2 ETED9MB
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX60 S2 ETED9PB
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX60 S2 ETED9DB
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX60 S2 ETED9SB
Disk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2 ETED9HB
Field upgrade options
Disk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2 ETED3HB-L
Disk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2 ETED4HB-L
Disk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2 ETED6HB-L
Disk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2 ETED9HB-L

2.5inch 7.2krpm SAS disk drive


Factory mount options
Product name Product ID
Disk Drive(2.5inch) 1TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN1MB
Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN1PB
Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN1DB
Disk Drive(2.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN1SB
Disk Drive(2.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HB
Field upgrade options
Disk Drive(2.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HB-L

#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different size disk drives is supported.
The capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,
600GB/10krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.

26
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Disk drive option (3.5inch disk drive)

ETERNUS DX60 S2

Disk drive
3.5inch disk drive
* Mandatory option
* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.

Factory mount options


Product name Product ID
Disk Drive(3.5inch) 300GB 15krpm x1 for DX60 S2 ETED3HA
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID5) for DX60 S2 ETED3PA
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID6) for DX60 S2 ETED3DA
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID1+0) for DX60 S2 ETED3SA
Disk Drive(3.5inch) 300GB 15krpm x2 (RAID1) for DX60 S2 ETED3MA
Disk Drive(3.5inch) 450GB 15krpm x2 (RAID1) for DX60 S2 ETED4MA
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID5)for DX60 S2 ETED4PA
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID6) for DX60 S2 ETED4DA
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID1+0) for DX60 S2 ETED4SA
Disk Drive(3.5inch) 450GB 15krpm x1 for DX60 S2 ETED4HA
Disk Drive(3.5inch) 600GB 15krpm x2 (RAID1) for DX60 S2 ETED6MA
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID5) for DX60 S2 ETED6PA
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID6) for DX60 S2 ETED6DA
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID1+0) for DX60 S2 ETED6SA
Disk Drive(3.5inch) 600GB 15krpm x1 for DX60 S2 ETED6HA
Disk Drive(3.5inch) 1TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN1MA
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN1PA
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN1DA
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN1SA
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HA
Disk Drive(3.5inch) 2TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN2MA
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN2PA
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN2DA
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN2SA
Disk Drive(3.5inch) 2TB 7.2krpm x1 for DX60 S2 ETEN2HA
Disk Drive(3.5inch) 3TB 7.2krpm x2 (RAID1) for DX60 S2 ETEN3MA
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID5) for DX60 S2 ETEN3PA
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID6) for DX60 S2 ETEN3DA
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID1+0) for DX60 S2 ETEN3SA
Disk Drive(3.5inch) 3TB 7.2krpm x1 for DX60 S2 ETEN3HA
Field upgrade options
Disk Drive(3.5inch) 300GB 15krpm x1 for DX60 S2 ETED3HA-L
Disk Drive(3.5inch) 450GB 15krpm x1 for DX60 S2 ETED4HA-L
Disk Drive(3.5inch) 600GB 15krpm x1 for DX60 S2 ETED6HA-L
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX60 S2 ETEN1HA-L
Disk Drive(3.5inch) 2TB 7.2krpm x1 for DX60 S2 ETEN2HA-L
Disk Drive(3.5inch) 3TB 7.2krpm x1 for DX60 S2 ETEN3HA-L

#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different capacity disk drives is supported.
When installing different capacity disk drives in one base unit,
the capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.
When installing different type disk drives in one base unit,
it is recommended that at least one hot spare disk of each type be installed.
#5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
27
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Drive enclosure (3.5inch)

ETERNUS DX60 S2
Dual-IOM type supports dual controller model only.

Drive enclosure for DX60 S2 (3.5inch, dual-expander type)


[Factory] ETEED2DU
[Field] ETEED2DU-L
- Rack mount type (2U)
- Enclosure [Expander (SAS 1port) x2, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment Qty Notes
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)
SAS cable 2 75cm: Bace unit <=>
Drive enclosure connection
Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.

Drive enclosure for DX60 S2 (3.5inch, single-expander type)


[Factory] ETEED1DU
[Field] ETEED1DU-L
- Rack mount type (2U)
- Enclosure [Expander (SAS 1port) x1, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment Qty Notes
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)
SAS cable 1 75cm: Bace unit <=>
Drive enclosure connection

Additional expander for DX60 S2 (3.5inch)


[Field] ETEEXD-L
- Attachment list
Attachment Qty Notes
IOM 1
SAS cable 1 75cm: Bace unit <=>
Drive enclosure connection

Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.

- Extension cable
ETERNUS DX60 S2

- The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)
supplied with the drive enclosures are too short to connect.

Extension cable between enclosures for DX60 S2 (3m)


[Field] ETEC1M3-L
- 1x mini SAS cable 3m 28
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options

- Disk drive option (2.5inch disk drive)


* 2.5inch drives are installed in the 2.5inch type controller enclosure and drive enclosures.

ETERNUS DX80 S2, DX90

Disk drive
2.5inch disk drive
* Mandatory option
* Up to 24 drives can be installed in a 2.5inch base unit or a 2.5inch drive enclosure.

2.5inch 10krpm SAS disk drive


Factory mount options
Product name Product ID
Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MC
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PC
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DC
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SC
Disk Drive(2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HC
Disk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4MC
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PC
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DC
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SC
Disk Drive(2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HC
Disk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6MC
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PC
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DC
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SC
Disk Drive(2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HC
Disk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED9MC
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED9PC
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED9DC
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED9SC
Disk Drive(2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HC
Field upgrade options
Disk Drive(2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HC-L
Disk Drive(2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HC-L
Disk Drive(2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HC-L
Disk Drive(2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HC-L

2.5inch 15krpm SAS disk drive


Factory mount options
Product name Product ID
Disk Drive (2.5inch) 300GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MG
Disk Drive (2.5inch) 300GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PG
Disk Drive (2.5inch) 300GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DG
Disk Drive (2.5inch) 300GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SG
Disk Drive (2.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HG
Field upgrade options
Disk Drive (2.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HG-L

2.5inch 7.2krpm SAS disk drive


Factory mount options
Product name Product ID
Disk Drive (2.5inch) 1TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN1MC
Disk Drive (2.5inch) 1TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN1PC
Disk Drive (2.5inch) 1TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN1DC
Disk Drive (2.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN1SC
Disk Drive (2.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HC
Field upgrade options
Disk Drive (2.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HC-L
29
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
Self Encrypting Disk Drive, 2.5inch 10krpm SAS disk drive
Factory mount options
Product name Product ID
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3ME
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PE
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DE
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SE
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HE
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4ME
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PE
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DE
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SE
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HE
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6ME
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PE
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DE
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SE
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HE
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED9ME
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED9PE
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED9DE
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED9SE
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HE
Field upgrade options
Self Encrypting Disk Drive (2.5inch) 300GB 10krpm x1 for DX80 S2/DX90 S2 ETED3HE-L
Self Encrypting Disk Drive (2.5inch) 450GB 10krpm x1 for DX80 S2/DX90 S2 ETED4HE-L
Self Encrypting Disk Drive (2.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HE-L
Self Encrypting Disk Drive (2.5inch) 900GB 10krpm x1 for DX80 S2/DX90 S2 ETED9HE-L

#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different size disk drives is supported.
The capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,
600GB/10krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.

30
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
'- Disk drive option (3.5inch disk drive)

ETERNUS DX80 S2, DX90

Disk drive
3.5inch disk drive
* Mandatory option
* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.

Factory mount options


Product name Product ID
Disk Drive(3.5inch) 300GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED3MD
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED3PD
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED3DD
Disk Drive(3.5inch) 300GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED3SD
Disk Drive(3.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HD
Disk Drive(3.5inch) 450GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED4MD
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED4PD
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED4DD
Disk Drive(3.5inch) 450GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED4SD
Disk Drive(3.5inch) 450GB 15krpm x1 for DX80 S2/DX90 S2 ETED4HD
Disk Drive(3.5inch) 600GB 15krpm x2 (RAID1) for DX80 S2/DX90 S2 ETED6MD
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID5) for DX80 S2/DX90 S2 ETED6PD
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID6) for DX80 S2/DX90 S2 ETED6DD
Disk Drive(3.5inch) 600GB 15krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETED6SD
Disk Drive(3.5inch) 600GB 10krpm x1 for DX80 S2/DX90 S2 ETED6HD
Disk Drive(3.5inch) 1TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN1MD
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN1PD
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN1DD
Disk Drive(3.5inch) 1TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN1SD
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HD
Disk Drive(3.5inch) 2TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN2MD
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN2PD
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN2DD
Disk Drive(3.5inch) 2TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN2SD
Disk Drive(3.5inch) 2TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN2HD
Disk Drive(3.5inch) 3TB 7.2krpm x2 (RAID1) for DX80 S2/DX90 S2 ETEN3MD
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID5) for DX80 S2/DX90 S2 ETEN3PD
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID6) for DX80 S2/DX90 S2 ETEN3DD
Disk Drive(3.5inch) 3TB 7.2krpm x6 (RAID1+0) for DX80 S2/DX90 S2 ETEN3SD
Disk Drive(3.5inch) 3TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN3HD
Field upgrade options
Disk Drive(3.5inch) 300GB 15krpm x1 for DX80 S2/DX90 S2 ETED3HD-L
Disk Drive(3.5inch) 450GB 15krpm x1 for DX80 S2/DX90 S2 ETED4HD-L
Disk Drive(3.5inch) 600GB 15krpm x1 for DX80 S2/DX90 S2 ETED6HD-L
Disk Drive(3.5inch) 1TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN1HD-L
Disk Drive(3.5inch) 2TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN2HD-L
Disk Drive(3.5inch) 3TB 7.2krpm x1 for DX80 S2/DX90 S2 ETEN3HD-L

#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different capacity disk drives is supported.
When installing different capacity disk drives in one base unit,
the capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.
When installing different type disk drives in one base unit,
it is recommended that at least one hot spare disk of each type be installed.
#5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
31
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- SSD

ETERNUS DX80 S2, DX90

SSD
2.5inch disk drives
Factory mount options
Product name Product ID
SSD(2.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2 ETES1MC
SSD(2.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2 ETES1PC
SSD(2.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES1SC
SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HC
SSD(2.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2 ETES2MC
SSD(2.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2 ETES2PC
SSD(2.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES2SC
SSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HC
SSD(2.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2 ETES4MC
SSD(2.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2 ETES4PC
SSD(2.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES4SC
SSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HC
SSD(2.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2 ETES8MC
SSD(2.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2 ETES8PC
SSD(2.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES8SC
SSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HC
Field upgrade options
SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HC-L
SSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HC-L
SSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HC-L
SSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HC-L

SSD
3.5inch disk drives
Factory mount options
SSD(3.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2 ETES1MD
SSD(3.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2 ETES1PD
SSD(3.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES1SD
SSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HD
SSD(3.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2 ETES2MD
SSD(3.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2 ETES2PD
SSD(3.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES2SD
SSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HD
SSD(3.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2 ETES4MD
SSD(3.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2 ETES4PD
SSD(3.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES4SD
SSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HD
SSD(3.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2 ETES8MD
SSD(3.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2 ETES8PD
SSD(3.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES8SD
SSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HD
Field upgrade options
SSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HD-L
SSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HD-L
SSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HD-L
SSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HD-L

* SSD supports RAID1, RAID1+0 and RAID5 only.

32
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Drive enclosure (2.5inch)

ETERNUS DX80 S2, DX90 S2


Dual-IOM type supports dual controller model only.

Drive enclosure for DX80 S2/DX90 S2 (2.5inch, dual-IOM type)


[Factory] ETEAD2CU
[Field] ETEAD2CU-L
- Rack mount type (2U)
- Enclosure [IOM (SAS 1port) x2, PSU x2] x1
- Up to 24 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment Qty Notes
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)
SAS cable 2 75cm: Bace unit <=>
Drive enclosure connection
Disk drive
Refer "Disk drive option (2.5inch)"
* Up to 24 disk drives can be installed.

Drive enclosure for DX80 S2/DX90 S2 (2.5inch, single-IOM type)


[Factory] ETEAD1CU
[Field] ETEAD1CU-L
- Rack mount type (2U)
- Enclosure [IOM (SAS 1port) x1, PSU x2] x1
- Up to 24 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment Qty Notes
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)
SAS cable 1 75cm: Bace unit <=>
Drive enclosure connection

Additional IOM for DX80 S2/DX90 S2


[Field] ETEAMA-L
- Attachment list
Attachment Qty Notes
IOM 1
SAS cable 1 75cm: Bace unit <=>
Drive enclosure connection

Disk drive
Refer "Disk drive option (2.5inch)"
* Up to 24 disk drives can be installed.

33
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Drive enclosure (3.5inch)

ETERNUS DX80 S2, DX90 S2


Dual-IOM type supports dual controller model only.

Drive enclosure for DX80 S2/DX90 S2 (3.5inch, dual-IOM type)


[Factory] ETEAD2DU
[Field] ETEAD2DU-L
- Rack mount type (2U)
- Enclosure [IOM (SAS 1port) x2, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment Qty Notes
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)
SAS cable 2 75cm: Bace unit <=> Drive enclosure connection
Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.

Drive enclosure for DX80 S2/DX90 S2 (3.5inch, single-IOM type)


[Factory] ETEAD1DU
[Field] ETEAD1DU-L
- Rack mount type (2U)
- Enclosure [IOM (SAS 1port) x1, PSU x2] x1
- Up to 12 disk drives can be installed in one drive enclosure.
- Attachment list
Attachment Qty Notes
Rackmount kit 1 set
AC200V power cable 2 4m (NEMA L6-15P)
SAS cable 2 75cm: Bace unit <=> Drive enclosure connection

Additional IOM for DX80 S2/DX90 S2


[Field] ETEAMA-L
- Attachment list
Attachment Qty Notes
Rackmount kit 1 set
SAS cable 2 75cm: Bace unit <=> Drive enclosure connection

Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.

- Extension cable
ETERNUS DX80 S2, DX90 S2

- The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)
supplied with the drive enclosures are too short to connect.

Extension cable between enclosures for DX80 S2/DX90 S2 (3m)


[Field] ETEC1Q3-L
- QSFP cable (3m) x1

Extension cable between enclosures for DX80 S2/DX90 S2 (6m)


[Field] ETEC1Q6-L
- QSFP cable (6m) x1 34
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options

- Thin Provisioning Feature

ETERNUS DX80 S2 Single controller model does not support Thin Provisioning Feature.

Thin Provisioning Feature License for DX80 S2


[Factory] ETEL8T
[Field] ETEL8T-L
- License label x1
- To use Thin provisioning Feature, one license is required per one unit.

ETERNUS DX90 S2

Thin Provisioning Feature License for DX90 S2


[Factory] ETEL9T
[Field] ETEL9T-L
- License label x1
- To use Thin provisioning Feature, one license is required per one unit.

[Factory]: Factory mount option


[Field]: Field upgrade option

35
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options

- Outlet box
ETERNUS DX60 S2, DX80 S2, DX90

- Power distribution unit


Power distribution unit for DX60 S2/DX80 S2/DX90 S2
(AC200-240V, 1U Max 2 enclosures connection)
ETEP4BU-L
Rack mount type (1U), AC200V
There are up to two options for connecting a base unit and
drive enclosure.
(PDU for Base unit x2 or PDU for Drive enclosure x2 or
PDU for Base unit x1 + PDU for Drive enclosure x1)
- Power distribution unit (AC200V)1
- Input AC cable (NEMA L6-15P, 3m) x2
- Output AC cable (3m) x4, Rack mount kit x1

NEMA L6-15 outlet

Power distribution unit for DX60 S2/DX80 S2/DX90 S2


(AC200-240V, 2U, Max 6 enclosures connection)
ETEP12U-L
Rack mount type (1U), AC200V
Up to six base units or drive enclosures can be connected.
(Base unit x6,
Base unit x2 + Drive enclosure x4
Base unit x1 + Drive enclosure x5, etc.)
- Power distribution unit (AC200V)1
- Input AC cable (NEMA L6-20P, 4m) x2
- Output AC cable (3m) x12, Rackmount kit x1

NEMA L6-20 outlet

Power distribution unit for DX60 S2/DX80 S2/DX90 S2


(AC200-240V, 2U, Max 8 enclosures connection)
ETEP16U-L
Rack mount type (1U), AC200V
Up to eight base units or drive enclosures can be connected.
(Base unit x8,
Base unit x2 + Drive enclosure x6
Base unit x1 + Drive enclosure x7, etc.)
- Power distribution unit (AC200V)1
- Input AC cable (NEMA L6-30P, 4m) x2
- Output AC cable (3m) x16, Rackmount kit x1

NEMA L6-30 outlet

36
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options

ETERNUS DX60 S2, DX80 S2, DX90

- IEC Power cable


AC cable (IEC60320 C13 - IEC60320 C14)
ST-PWG13
- To connect IEC 320-C14 components,
one option is required per one base unit or drive enclosure.
- AC200V cable (IEC320 C14, 3m) x2
200V (Standard) IEC320

NEMA L6-15 outlet IEC320 outlet

37
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options

ETERNUS DX60 S2, DX80 S2, DX90

Power Synchronized Unit


ST-PSM20U
- Power Synchronized Unit x1
- RS232C cable x2
- Parts kit for 19-inch rack

AC Sensor Unit (AC200V)


ST-PSL20SU
- AC Sensor Unit x1
- RCI cable (4m) x1
- RCI brunch connector x1
- Parts kit for 19-inch rack

Note that power cords (for AC power input) for power synchronized units and power cords (for AC sensor) to connect
server UPS units to power synchronized units or AC sensor units are not supplied with power synchronized units.

The IEC 60320-C14 port type is used for the AC IN ports and the SENSOR ports of the power synchronized units.
This port type is also used for the AC IN ports of the AC sensor units.
Check the specifications of the power sockets and server UPS unit outlets that are to be used for the power
synchronized units and AC sensor units. Prepare the required number of appropriate power cords.

Power cord (for AC power input)


- Each Power Synchronized Unit requires one Power cord.
- The voltage for the AC IN port is 10A 250V or less.
Power cord (for AC sensor)
- Each server UPS Unit that is to be connected to The Power Synchronized Unit requires one Power cord.
- Each AC sensor Unit requires one Power cord.

Be sure that the power cords have the approval of the appropriate safety agencies of the country where the equipment
will be used.

38
ETERNUS DX60 S2, DX80 S2, DX90 S2
(8) Cables

- Fibre channel cable (Fibre channel, 10Gbits/s iSCSI, FCoE connection)


ETERNUS DX60 S2 Fibre channel cable
ETERNUS DX80 S2 Product ID Length Notes
ETERNUS DX90 S2 CBL-MLLC05 5m LC-LC
CBL-MLLC10 10m
CBL-MLLC20 20m
CBL-MLLC30 30m With cover
CBL-MLLC40 40m
CBL-MLLC50 50m
CBL-MLLD1A 100m
CBL-MLLB02 * 2m
CBL-MLLB05 * 5m Without cover
CBL-MLLB15 * 15m
* For connection between same rack.
Fibre channel card, Fibre channel switch

- SAS cable (SAS connection)


ETERNUS DX60 S2 SAS cable
ETERNUS DX80 S2 Product ID Length Notes
ETERNUS DX90 S2 CBL-SASB1U 1.5m - SAS connection
CBL-SASB3U 3m
CBL-SASB6U 6m

SAS card

- Twinax Cable (10 Gbit/s iSCSI withtout SFP+, FCoE without SFP+ connection)
ETERNUS DX80 S2 Twinax cable
ETERNUS DX90 S2 Product ID Type Notes
EBRTWX11 1m Brocade/10G-SFPP-TWX-0101
EBRTWX31 3m Brocade/10G-SFPP-TWX-0301
EBRTWX51 5m Brocade/10G-SFPP-TWX-0501
S26361-F4571-L107 7m Cisco/SFP-H10GB-ACU7M
S26361-F4571-L110 10m Cisco/SFP-H10GB-ACU10M
S26361-F3989-L105 5m Fujitsu/T26139-Y4006-M5

FCoE, iSCSI card

39
ETERNUS DX60 S2, DX80 S2, DX90 S2
(9) Rack

- Rack for ETERNUS DX60 S2, DX80 S2, DX90 S2

ETERNUS DX80 S2, DX90 S2 can be installed in the following racks.


Product ID
Product name Height
Base Rack Expansion Rack
19-inch Rack Model 2742 Standard 42U 19R-274A2 19R-274B2
19-inch Rack Model 2737 Standard 37U 19R-273A2 19R-273B2
19-inch Rack Model 2724 Standard 24U 19R-272A2 -
19-inch Rack Model 2642 Slim 42U 19R-264A2 19R-264B2
19-inch Rack Model 2624 Slim 24U 19R-262A2 -
19-inch Rack Model 2616 Slim 16U 19R-261A2 -
19-inch rack without stabilizers 40U ETNRKC2U ETNRKD2U
19-inch rack with stabilizers 40U ETNRKC1U ETNRKD1U

- Notes

- Height and rack installation order are as follows.


Install order for the
Product name Product ID Height
rack
ETEAD2CU, ETEAD2CU-L
Drive enclosure 3
ETEAD2DU, ETEAD2DU-L
2U
ETERNUS DX80 S2 base unit ET082DCU, ET082DDU
2
ETERNUS DX90 S2 base unit ET092DCU, ET092DDU
ETEP4BU-L 1U
Power distribution unit (AC200V) ETEP12U-L 1
2U
ETEP16U-L

40
ETERNUS DX60 S2, DX80 S2, DX90 S2
(10) ETERNUS Multipath Driver

OS Product ID Product name


B025C1020H Windows ETERNUS Multipath Driver for Entry Model V2.x
Windows B025C1120H Windows ETERNUS Multipath Driver for Standard Model V2.x
B025C1220H Windows ETERNUS Multipath Driver for Enterprise Model V2.x
Solaris B011103H0H Solaris ETERNUS Multipath Driver 3.x
Linux B0214G2H0H ETERNUS Multipath Driver V2 (Linux 32bit/64bit)
AIX B013162H0H AIX ETERNUS Multipath Driver 2

41

Вам также может понравиться