Академический Документы
Профессиональный Документы
Культура Документы
[Specification]
(1) ETERNUS DX60 S2 1
(2) ETERNUS DX80 S2 2
(3) ETERNUS DX90 S2 3
(4) Supported RAID 4
[Outline]
(1) View 5
(2) Product Diagrams 7
Drive enclosure
Select only
connections
- Rackmount type 2U
Concurrent
permitted
ETLDE2AU
1
ETERNUS DX60 S2, DX80 S2, DX90 S2
2
ETERNUS DX60 S2, DX80 S2, DX90 S2
3
ETERNUS DX60 S2, DX80 S2, DX90 S2
(4) Supported RAID
The ETERNUS DX60 S2/DX80 S2/DX90 S2 support the following RAID levels.
Use of RAID0 is not recommended because it is not redundant.
For RAID0 configurations, data may be lost due to disk drive failure.
4
ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX60 S2 View
- Base unit
Front Cover
Controller (Standard)
(Additional Controller (Option))
LAN port
- Drive Enclosure
Front Cover
5
ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX80 S2, DX90 S2 View
Controller (Standard)
(Additional Controller (Option))
LAN port
- Drive Enclosure
6
ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX60 S2 Product Diagrams
Server
LAN cable (category 5e) 5m x 2
HBA (Host Bus Adaptor): (Setup node/Management LAN
FC / SAS / LAN card Connection)(Option)
Disk Drive (Option) (Max, 12 drives can be installed) AC power cable 200V 4m x2
*1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.
(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)
*2: The following table shows the type and number of drive enclosures that can be installed in DX60 S2.
Drive Enclosure
Base unit
3.5" type 2.5" type
3.5" type Max. 1 Not supported
ETERNUS DX60 S2
2.5" type Not supported Not supported
7
ETERNUS DX60 S2, DX80 S2, DX90 S2
ETERNUS DX80 S2, DX90 S2 Product Diagrams
Server
*1: Up to twelve 3.5" disk drives or twenty-four 2.5" disk drives can be installed in each controller enclosure.
(Mixture of 2.5/3.5inch drives in the same enclosure is not supported.)
*2: Mixture of 3.5" type drive enclosures and 2.5" type drive enclosures enables
mixture of 3.5" drives and 2.5" drives in the same machine.
Up to 120 drives can be installed in a single ETERNUS DX80 S2.
Up to 240 drives can be installed in a single ETERNUS DX90 S2.
The following table shows the type and number of drive enclosures that can be installed in DX80 S2/DX90 S2.
Drive Enclosure
Base unit
3.5" type 2.5" type
3.5" type Max. 9 Max. 4
ETERNUS DX80 S2
2.5" type Max. 9 Max. 4
3.5" type Max. 9 Max. 9
ETERNUS DX90 S2
2.5" type Max. 9 Max. 9
8
ETERNUS DX60 S2, DX80 S2, DX90 S2
(1) ETERNUS DX60 S2 (dual-controller type)
i) ETERNUS DX60 S2 base unit (Dual controller type, Fibre Channel connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 4Gbps, FC, dual-controller) (3.5inch, 4Gbps, FC, dual-controller)
Product ID ET062DCFU ET062DDFU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (FC4Gbit/s x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
ii) ETERNUS DX60 S2 base unit (Dual controller type, SAS connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 3Gbps, SAS, dual-controller) (3.5inch, 3Gbps, SAS, dual-controller)
Product ID ET062DCSU ET062DDSU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (SAS x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
9
ETERNUS DX60 S2, DX80 S2, DX90 S2
(1) ETERNUS DX60 S2 (dual-controller type)
iii) ETERNUS DX60 S2 Base Unit (Dual controller type, iSCSI connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 1Gbps, iSCSI, dual- (3.5inch, 1Gbps, iSCSI, dual-
Product ID ET062DCLU ET062DDLU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (iSCSI x 2ports) x2
- Cache memory (1G) x2
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
10
ETERNUS DX60 S2, DX80 S2, DX90 S2
(2) ETERNUS DX60 S2 (single-controller type)
i) ETERNUS DX60 S2 base unit (Single controller type, Fibre Channel connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 4Gbps, FC, Single-controller) (3.5inch, 4Gbps, FC, Single-controller)
Product ID ET062SCFU ET062SDFU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (FC4Gbit/s x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
11
ETERNUS DX60 S2, DX80 S2, DX90 S2
(2) ETERNUS DX60 S2 (single-controller type)
ii) ETERNUS DX60 S2 base unit (Single controller type, SAS connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 3Gbps, SAS, Single- (3.5inch, 3Gbps, SAS, Single-
Product ID ET062SCSU ET062SDSU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (SAS x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
12
ETERNUS DX60 S2, DX80 S2, DX90 S2
(2) ETERNUS DX60 S2 (single-controller type)
iii) ETERNUS DX60 S2 Base Unit (Single controller type, iSCSI connection)
ETERNUS DX60 S2 ETERNUS DX60 S2
Product name
(2.5inch, 1Gbps, iSCSI, Single- (3.5inch, 1Gbps, iSCSI, Single-
Product ID ET062SCLU ET062SDLU
Rackmount type (2U), AC200V model
Enclosure x1
Configuration - Controller (iSCSI x 2ports) x1
- Cache memory (1G) x1
- Power Supply Unit x2
At least two disk drives are mandatory. Up to 24 drives can be added.
Up to 24 drives can be installed in 2.5" type base unit.
Notes Up to 12 drives can be installed in 3.5" type base unit and drive enclosure.
2.5" Drive Enclosure cannot be added.
One 3.5" Drive Enclosures can be added.
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
13
ETERNUS DX60 S2, DX80 S2, DX90 S2
(3) ETERNUS DX80 S2 (dual-controller type)
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
14
ETERNUS DX60 S2, DX80 S2, DX90 S2
(3) ETERNUS DX80 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1
15
ETERNUS DX60 S2, DX80 S2, DX90 S2
(3) ETERNUS DX80 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1
16
ETERNUS DX60 S2, DX80 S2, DX90 S2
(4) ETERNUS DX80 S2 (Single-controller type)
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
17
ETERNUS DX60 S2, DX80 S2, DX90 S2
(4) ETERNUS DX80 S2 (Single-controller type)
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G)18
x1
ETERNUS DX60 S2, DX80 S2, DX90 S2
(4) ETERNUS DX80 S2 (Single-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1
19
ETERNUS DX60 S2, DX80 S2, DX90 S2
(5) ETERNUS DX90 S2 (dual-controller type)
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
20
ETERNUS DX60 S2, DX80 S2, DX90 S2
(5) ETERNUS DX90 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G) x1
21
ETERNUS DX60 S2, DX80 S2, DX90 S2
(5) ETERNUS DX90 S2 (dual-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1
22
ETERNUS DX60 S2, DX80 S2, DX90 S2
(6) ETERNUS DX90 S2 (single-controller type)
- Contents of Package
Components Quantity Note
AC200V power cord 2 4m (NEMA L6-15P)
Rack mount kit 1 set
Safety Precautions 1
User Guide 1 CD
Read me first 1
23
ETERNUS DX60 S2, DX80 S2, DX90 S2
(6) ETERNUS DX90 S2 (single-controller type)
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Factory] ETEHY12
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, for optical cable)
[Field] ETEHY12-L
- Host interface module (iSCSI 10G) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Factory] ETEHY1N
- Host interface module (iSCSI 10G) x1
Host interface for DX80 S2/DX90 S2 (10Gbit/s, iSCSI, 2port, without SFP+, for copper cable)
[Field] ETEHY1N-L
- Host interface module (iSCSI 10G)24
x1
ETERNUS DX60 S2, DX80 S2, DX90 S2
(6) ETERNUS DX90 S2 (single-controller type)
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Factory] ETEHC12
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, for optical cable)
[Field] ETEHC12-L
- Host interface module (FCoE) x1
- SFP+ (10Gbit/s) x2
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Factory] ETEHC1N
- Host interface module (FCoE) x1
Host interface for DX80 S2/DX90 S2 (FCoE, 2port, without SFP+, for copper cable)
[Field] ETEHC1N-L
- Host interface module (FCoE) x1
25
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
ETERNUS DX60 S2
Disk drive
2.5inch disk drive
* Mandatory option
* Up to 24 drives can be installed in a 2.5inch base unit.
2.5inch 10krpm SAS disk drive
Factory mount options
Product name Product ID
Disk Drive(2.5inch) 300GB 10krpm x2 (RAID1) for DX60 S2 ETED3MB
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID5) for DX60 S2 ETED3PB
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID6) for DX60 S2 ETED3DB
Disk Drive(2.5inch) 300GB 10krpm x6 (RAID1+0) for DX60 S2 ETED3SB
Disk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2 ETED3HB
Disk Drive(2.5inch) 450GB 10krpm x2 (RAID1) for DX60 S2 ETED4MB
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID5) for DX60 S2 ETED4PB
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID6) for DX60 S2 ETED4DB
Disk Drive(2.5inch) 450GB 10krpm x6 (RAID1+0) for DX60 S2 ETED4SB
Disk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2 ETED4HB
Disk Drive(2.5inch) 600GB 10krpm x2 (RAID1) for DX60 S2 ETED6MB
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID5) for DX60 S2 ETED6PB
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID6) for DX60 S2 ETED6DB
Disk Drive(2.5inch) 600GB 10krpm x6 (RAID1+0) for DX60 S2 ETED6SB
Disk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2 ETED6HB
Disk Drive(2.5inch) 900GB 10krpm x2 (RAID1) for DX60 S2 ETED9MB
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID5) for DX60 S2 ETED9PB
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID6) for DX60 S2 ETED9DB
Disk Drive(2.5inch) 900GB 10krpm x6 (RAID1+0) for DX60 S2 ETED9SB
Disk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2 ETED9HB
Field upgrade options
Disk Drive(2.5inch) 300GB 10krpm x1 for DX60 S2 ETED3HB-L
Disk Drive(2.5inch) 450GB 10krpm x1 for DX60 S2 ETED4HB-L
Disk Drive(2.5inch) 600GB 10krpm x1 for DX60 S2 ETED6HB-L
Disk Drive(2.5inch) 900GB 10krpm x1 for DX60 S2 ETED9HB-L
#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different size disk drives is supported.
The capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,
600GB/10krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
26
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Disk drive option (3.5inch disk drive)
ETERNUS DX60 S2
Disk drive
3.5inch disk drive
* Mandatory option
* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.
#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different capacity disk drives is supported.
When installing different capacity disk drives in one base unit,
the capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.
When installing different type disk drives in one base unit,
it is recommended that at least one hot spare disk of each type be installed.
#5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
27
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Drive enclosure (3.5inch)
ETERNUS DX60 S2
Dual-IOM type supports dual controller model only.
Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.
- Extension cable
ETERNUS DX60 S2
- The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)
supplied with the drive enclosures are too short to connect.
Disk drive
2.5inch disk drive
* Mandatory option
* Up to 24 drives can be installed in a 2.5inch base unit or a 2.5inch drive enclosure.
#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different size disk drives is supported.
The capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/10krpm SAS disk x6 (RAID5) x1,
600GB/10krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
30
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
'- Disk drive option (3.5inch disk drive)
Disk drive
3.5inch disk drive
* Mandatory option
* Up to 12 drives can be installed in a 3.5inch base unit or a 3.5inch drive enclosure.
#1 Two or more disk drives are mandatory for one base unit.
#2 Install hot spare disks for stable operation.
#3 A mixture of different capacity disk drives is supported.
When installing different capacity disk drives in one base unit,
the capacity of the hot spare disk should match the capacity of the largest disk drive.
Ex.) 450GB/15krpm SAS disk x6 (RAID5) x1, 600GB/15krpm SAS disk x6 (RAID5) x1
=> 600GB disk drive x1 is the hot spare.
#4 A mixture of different disks (SAS disk drives and Nearline SAS disk drives) is supported.
When installing different type disk drives in one base unit,
it is recommended that at least one hot spare disk of each type be installed.
#5 A mixture of different disk drives cannot be used for a single RAID group. Same type disk drives
(same capacity, rotation speed and interface speed) are required.
31
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- SSD
SSD
2.5inch disk drives
Factory mount options
Product name Product ID
SSD(2.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2 ETES1MC
SSD(2.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2 ETES1PC
SSD(2.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES1SC
SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HC
SSD(2.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2 ETES2MC
SSD(2.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2 ETES2PC
SSD(2.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES2SC
SSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HC
SSD(2.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2 ETES4MC
SSD(2.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2 ETES4PC
SSD(2.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES4SC
SSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HC
SSD(2.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2 ETES8MC
SSD(2.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2 ETES8PC
SSD(2.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES8SC
SSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HC
Field upgrade options
SSD(2.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HC-L
SSD(2.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HC-L
SSD(2.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HC-L
SSD(2.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HC-L
SSD
3.5inch disk drives
Factory mount options
SSD(3.5inch) 100GB x2 (RAID1) for DX80 S2/DX90 S2 ETES1MD
SSD(3.5inch) 100GB x4 (RAID5) for DX80 S2/DX90 S2 ETES1PD
SSD(3.5inch) 100GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES1SD
SSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HD
SSD(3.5inch) 200GB x2 (RAID1) for DX80 S2/DX90 S2 ETES2MD
SSD(3.5inch) 200GB x4 (RAID5) for DX80 S2/DX90 S2 ETES2PD
SSD(3.5inch) 200GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES2SD
SSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HD
SSD(3.5inch) 400GB x2 (RAID1) for DX80 S2/DX90 S2 ETES4MD
SSD(3.5inch) 400GB x4 (RAID5) for DX80 S2/DX90 S2 ETES4PD
SSD(3.5inch) 400GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES4SD
SSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HD
SSD(3.5inch) 800GB x2 (RAID1) for DX80 S2/DX90 S2 ETES8MD
SSD(3.5inch) 800GB x4 (RAID5) for DX80 S2/DX90 S2 ETES8PD
SSD(3.5inch) 800GB x6 (RAID1+0) for DX80 S2/DX90 S2 ETES8SD
SSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HD
Field upgrade options
SSD(3.5inch) 100GB x1 for DX80 S2/DX90 S2 ETES1HD-L
SSD(3.5inch) 200GB x1 for DX80 S2/DX90 S2 ETES2HD-L
SSD(3.5inch) 400GB x1 for DX80 S2/DX90 S2 ETES4HD-L
SSD(3.5inch) 800GB x1 for DX80 S2/DX90 S2 ETES8HD-L
32
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Drive enclosure (2.5inch)
Disk drive
Refer "Disk drive option (2.5inch)"
* Up to 24 disk drives can be installed.
33
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Drive enclosure (3.5inch)
Disk drive
Refer "Disk drive option (3.5inch)"
* Up to 12 disk drives can be installed.
- Extension cable
ETERNUS DX80 S2, DX90 S2
- The Extension cable (3m) kit option can be ordered if the SAS cables (75cm)
supplied with the drive enclosures are too short to connect.
ETERNUS DX80 S2 Single controller model does not support Thin Provisioning Feature.
ETERNUS DX90 S2
35
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
- Outlet box
ETERNUS DX60 S2, DX80 S2, DX90
36
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
37
ETERNUS DX60 S2, DX80 S2, DX90 S2
(7) Options
Note that power cords (for AC power input) for power synchronized units and power cords (for AC sensor) to connect
server UPS units to power synchronized units or AC sensor units are not supplied with power synchronized units.
The IEC 60320-C14 port type is used for the AC IN ports and the SENSOR ports of the power synchronized units.
This port type is also used for the AC IN ports of the AC sensor units.
Check the specifications of the power sockets and server UPS unit outlets that are to be used for the power
synchronized units and AC sensor units. Prepare the required number of appropriate power cords.
Be sure that the power cords have the approval of the appropriate safety agencies of the country where the equipment
will be used.
38
ETERNUS DX60 S2, DX80 S2, DX90 S2
(8) Cables
SAS card
- Twinax Cable (10 Gbit/s iSCSI withtout SFP+, FCoE without SFP+ connection)
ETERNUS DX80 S2 Twinax cable
ETERNUS DX90 S2 Product ID Type Notes
EBRTWX11 1m Brocade/10G-SFPP-TWX-0101
EBRTWX31 3m Brocade/10G-SFPP-TWX-0301
EBRTWX51 5m Brocade/10G-SFPP-TWX-0501
S26361-F4571-L107 7m Cisco/SFP-H10GB-ACU7M
S26361-F4571-L110 10m Cisco/SFP-H10GB-ACU10M
S26361-F3989-L105 5m Fujitsu/T26139-Y4006-M5
39
ETERNUS DX60 S2, DX80 S2, DX90 S2
(9) Rack
- Notes
40
ETERNUS DX60 S2, DX80 S2, DX90 S2
(10) ETERNUS Multipath Driver
41