Вы находитесь на странице: 1из 11

Project Spreadsheets to BS 8110 etc The Concrete Centre

Client Advisory Group Made by Date Page


Location Grid line 2 rc 03-Apr-2017 127
Basement wall design to BS8110:2005 Checked Revision Job No
Originated from 'RCC61 Basement Wall.xls' v4.0 2006 TCC chg - R68
IDEALISED STRUCTURE and FORCE DIAGRAMS DESIGN STATUS : VALID

DIMENSIONS(mm)
H= 2850 B= 2000 Tw = 200
Hw = 0 BI = 0 Tb = 400
He = 2850

MATERIAL PROPERTIES steel class A


fcu = 25 N/mm2 m = 1.50 concrete
fy = 416 N/mm2 m = 1.15 steel
Cover to tension reinforcement (co) = 40 mm
Max. allowable design surface crack width (W) = 0.2 mm (0.2 or 0.3
mm only)
Concrete density = 24.0 kN/m3 Wall Geometry

SOIL PROPERTIES
Design angle of int'l friction of retained mat'l () = 30 degree
Design cohesion of retained mat'l (C ) = 0 kN/m2 (Only granular backfill considered, ie "C" = 0)
Density of retained mat'l (q ) = 18 kN/m3
Submerged Density of retained mat'l (qs ) = 18.00 kN/m3 (default=2/3 of q), only apply when Hw >0
Design angle of int'l friction of base mat'l (b) = 30 degree = 18.00
Design cohesion of base mat'l (Cb ) = 5 kN/m2 ASSUMPTIONS
Density of base mat'l (qb ) = 18 kN/m3 a) Wall friction is zero
Allowable gross ground bearing pressure (GBP) = 150 kN/m2 b) Minimum active earth pressure = 0.25qH
LOADINGS (unfactored) c) Granular backfill
Surcharge load -- live (SQK) = 5 kN/m2 h) Design not intended for walls over 3.5 m high
Surcharge load -- dead (SGK) = 0 kN/m2 i)Does not include check for temp or shrinkage effects
Line load -- live (LQK) = 0 kN/m
Line load -- dead (LGK) = 0 kN/m
Distance of line load from wall (X) = 0 mm
Wall load -- live (WQK) = 0 kN/m
Wall load -- Dead (WGK) = 13.68 kN/m

LATERAL FORCES Ko = 0.50 default Ko = (1-SIN ) 0.50


Kac = 1.41 = 2Ko0.5

Force (kN) Lever arm (m) f Ultimate Force (kN)


PE = 36.55 LE = 0.950 1.40 51.17
PS(GK) = 0.00 LS = 1.43 1.40 0.00
PS(QK) = 7.12 LS = 1.43 1.60 11.40
PL(GK) = 0.00 LL = 2.85 1.40 0.00
PL(QK) = 0.00 LL = 2.85 1.60 0.00
PW = 0.00 LW = 0.00 1.40 0.00
Total 43.68 62.57
Project Spreadsheets to BS 8110 etc The Concrete Centre
Client Advisory Group Made by Date Page
Location Grid line 2 rc 03-Apr-2017 128
Basement wall design to BS8110:2005 Checked Revision Job No
Originated from 'RCC61 Basement Wall.xls' v4.0 2006 TCC chg - R68

EXTERNAL STABILITY STABILITY CHECK : OK

ANALYSIS - Assumptions & Notes

1) Wall idealised as a propped cantilever ( i.e. pinned at top and fixed at base )
2) Wall is braced.
3) Maximum slenderness of wall is limited to 15, i.e [ 0.9*(He-Tb/2)/Tw < 15 ]
4) Maximum Ultimate axial load on wall is limited to 0.1fcu times the wall cross-sectional area
5) Design Span (Effective wall height) = He - (Tb/2)
6) -ve moment is hogging ( i.e. tension at external face of wall )
+ve moment is sagging ( i.e. tension at internal face of wall )
7) " Wall MT. " is maximum +ve moment on the wall.
8) Estimated lateral deflections are used for checking the P effect .

UNFACTORED LOADS AND FORCES

Force Lever arm Base MT. Wall MT. Reaction at Reaction at Estimated Elastic
Lateral Force (kN) to base (m) (kNm) (kNm) Base (kN) Top (kN) Deflection (mm)
PE = 31.60 0.88 -11.17 4.99 25.28 6.32 0.4
PS(GK) = 0.00 1.33 0.00 #DIV/0! 0.00 0.00 0.0
PS(QK) = 6.62 1.33 -2.19 1.23 4.14 2.48 0.1
PL(GK) = 0.00 2.65 0.00 0.00 0.00 0.00 0.0
PL(QK) = 0.00 2.65 0.00 0.00 0.00 0.00 0.0
PW = 0.00 0.00 0.00 0.00 0.00 0.00 0.0
Total 38.23 -13.36 #DIV/0! 29.42 8.80 0.5

GROUND BEARING FAILURE


LOAD CASE: Wall Load MAX 1
Taking moments about centre of base (anticlockwise "+") Surcharge MIN 0

Vertical FORCES (kN) Lever arm (m) Moment (kNm)


BEARING PRESSURE (kN/m)
Wall load = 13.68 0.90 12.3119998632
Wall (sw) = 11.76 0.90 10.58
0.000
Base = 19.20 0.00 0.00
Earth = 0.00 1.00 0.00
Water = 0.00 1.00 0.00
Surcharge = 0.00 1.00 0.00
Line load = 0.00 1.00 0.00
V = 44.64 Mv = 22.90

MOMENT due to LATERAL FORCES, Mo = -11.17 kNm 50.000

RESULTANT MOMENT, M = Mv + Mo = 11.73 kNm

ECCENTRICITY FROM BASE CENTRE, M / V = 0.26 m


MAXIMUM GROSS BEARING PRESSURE = 39.92 kN/m2 < 150 OK

SLIDING AT BASE (using overall factor of safety instead of partial safety f F.O.S = 1.50

SUM of LATERAL FORCES, P = 29.42 kN


BASE FRICTION, Fb = - ( V TANb + B.Cb ) = -35.77 kN

Factor of Safety, Fb / P = 1.22 < 1.50 FAIL .. but

therefore, LATERAL RESISTANCE to be provided by BASEMENT SLAB = 8.36 kN


Project Spreadsheets to BS 8110 etc The Concrete Centre
Client Advisory Group Made by Date Page
Location Grid line 2 rc 03-Apr-2017 130
Basement wall design to BS8110:2005 Checked Revision Job No
Originated from 'RCC61 Basement Wall.xls' v4.0 2006 TCC chg - R68

OUTER BASE ( per metre length ) BS8110


f = 1.50 (ASSUMED) reference
Ult. Shear = 23.28 kN (AT d from FACE of WALL)
Ult. MT. = 0.00 kNm TENSION - TOP FACE

BOTTOM REINFORCEMENT : Min. As = 960 mm2 Table 3.25


= 16 mm
centres = 150 mm < 766 OK
As = 1340 mm2 > 960 OK

MOMENT of RESISTANCE : d = 352 mm


Z = 330 mm 3.4.4.4
As' = 0 mm2
Mres = 160.15 kNm > 0.00 OK

SHEAR RESISTANCE: 100As/bd = 0.88%


vc = 0.47 N/mm2 Table 3.8
Vres = 166.48 kN > 23.28 OK 3.5.5.2

CHECK CRACK WIDTH IN ACCORDANCE WITH BS8100/8007 : Temp & shrinkage effects not included
X= 107.96 mm m = -0.00043 BS8007
Acr = 81.04 mm W= -0.08 mm < 0.20 OK App. B.2
NO CRACKING

INNER BASE ( per metre length )


Ult. Shear = -13.20 kN (AT d from FACE of WALL)
Ult. MT. = 20.04 kNm TENSION - BOTTOM FACE

BOTTOM REINFORCEMENT : Min. As = 960 mm2 Table 3.25


= 16 mm
centres = 150 mm < 766 OK
As = 1340 mm2 > 960 OK

MOMENT of RESISTANCE : d = 352 mm


Z = 330 mm
As' = 0 mm2
Mres = 160.15 kNm > 20.04 OK 3.4.4.4

SHEAR RESISTANCE: 100As/bd = 0.38%


vc = 0.47 N/mm2 Table 3.8
Vres = 166.48 kN > 13.20 OK 3.5.5.2

CHECK CRACK WIDTH IN ACCORDANCE WITH BS8100/8007 : Temp & shrinkage effects not included
X= 107.96 mm m = -0.00025 BS8007
Acr = 81.04 mm W= -0.05 mm < 0.20 OK App. B.2
NO CRACKING

REINFORCEMENT SUMMARY for BASE


Type centres As Min. As
mm mm mm 2
mm2
TOP R 16 150 1340 960 OK
BOTTOM R 16 150 1340 960 OK
TRANSVERSE R 16 150 1340 960 OK
Project Spreadsheets to BS 8110 etc The Concrete Centre
Client Advisory Group Made by Date Page
Location Grid line 2 rc 03-Apr-2017 131
Basement wall design to BS8110:2005 Checked Revision Job No
Originated from 'RCC61 Basement Wall.xls' v4.0 2006 TCC chg - R68

APPROXIMATE WEIGHT OF REINFORCEMENT per metre length of wall

No. Type Dia Length Unit Wt Weight

WALL VERTICAL - Internal face 7 R 16 2578 1.578 28.48


VERTICAL - External face 7 R 16 2578 1.578 28.48
TRANSVERSE (Ext.+ Int.) 34 R 12 1000 0.888 30.19

BASE TOP (MAIN) 7 R 16 2128 1.578 23.51


BOTTOM (MAIN) 7 R 16 2128 1.578 23.51
TRANSVERSE ( T & B ) 28 R 16 1000 1.578 44.19
WALL STARTERS (Int.) 7 R 16(30+8)*G17+75+TB
1.578 #VALUE!
WALL STARTERS (Ext.) 7 R 16(30+8)*G17+75+TB
1.578 #VALUE!

SUMMARY Total reinforcement per metre length of wall (kg) #VALUE!


Project Spreadsheets to BS 8110 etc
Location Grid line 2 DATA FOR DIAGRAMS I
Basement wall design to BS8110:2005 sheet 1 of 2 Made by rc Job No R68
Originated from 'RCC61 Basement Wall.xls' v4.0 2006 TCC Date

XX= 0

IF(ECCY>(B/1000)/6,IF(XX>(B/1000/2-ECCY)*3,0,(((B/1000/2-ECCY)*3-XX)/((B/1000/2-ECCY)*3))*BP),((VL/(B/1000)*(1-(6*ECCY)/(B/1000))))+(B/1000-XX)/(B/1000)*(BP-(VL/
(B/1000)*(1-(6*ECCY)/(B/1000)))))

IF(ABS(ECCY)>(B/1000)/6,IF((B-XX)>(B/1000/2-ABS(ECCY))*3,0,(((B/1000/2-ABS(ECCY))*3-(B-XX))/((B/1000/2-ABS(ECCY))*3))*BP),((VL/(B/1000)*(1-
(6*ABS(ECCY))/(B/1000)))) +(B/1000-(B-XX))/(B/1000)*(BP-(VL/(B/1000)*(1-(6*ABS(ECCY))/(B/1000)))))

IF(ABS(ECCY)>(B/1000)/6,IF(XX>(B/1000/2-ABS(ECCY))*3,0,(((B/1000/2-ABS(ECCY))*3-XX)/((B/1000/2-ABS(ECCY))*3))*BP), ((VL/(B/1000)* (1-6*ABS(ECCY))/


(B/1000))))+(B/1000-XX)/(B/1000)*(BP-(VL/(B/1000)*(1-(6*ABS(ECCY))/(B/1000)))))
39.91537
39.91537
0 0.00 39.915 0 39.92 0.0000 0.00 0.00 0.04 1.60
M
1 0.04 39.212 BEARING PRESSURE DIAGRAM 1 39.21 0 0.00 0.00 0.04 1.57
2 0.08 38.508 2 38.51 0 0.00 0.00 0.04 1.54
3 0.12 37.804 3 37.80 0 0.00 0.00 0.04 1.51
4 0.16 37.100 0.000 4 37.10 0 0.00 0.00 0.04 1.48
KN/M^2

5 0.20 36.396 5 36.40 0 0.00 0.00 0.04 1.46


6 0.24 35.692 6 35.69 0 0.00 0.00 0.04 1.43
7 0.28 34.989 7 34.99 0 0.00 0.00 0.04 1.40
8 0.32 34.285 8 34.28 0 0.00 0.00 0.04 1.37
9 0.36 33.581 9 33.58 0 0.00 0.00 0.04 1.34
10 0.40 32.877 10 32.88 0 0.00 0.00 0.04 1.32
11 0.44 32.173 11 32.17 0 0.00 0.00 0.04 1.29
12 0.48 31.470 12 31.47 0 0.00 0.00 0.04 1.26
50.000
13 0.52 30.766 13 30.77 0 0.00 0.00 0 0.00
14 0.56 30.062 14 30.06 0 0.00 0.00 0 0.00
15 0.60 29.358 15 29.36 0 0.00 0.00 0 0.00
16 0.64 28.654 39.915 16 28.65 0 0.00 0.00 0 0.00
17 0.68 27.951 BPO 0 39.915 17 27.95 0 0.00 0.00 0 0.00
18 0.72 27.247 BPE 1E-008 39.915 18 27.25 0 0.00 0.00 0 0.00
19 0.76 26.543 BPI 0.2 36.396 19 26.54 0 0.00 0.00 0 0.00
20 0.80 25.839 BPZ 2 4.7246 20 25.84 0 0.00 0.00 0 0.00
21 0.84 25.135 21 25.14 0 0.00 0.00 0 0.00
22 0.88 24.431 22 24.43 0 0.00 0.00 0 0.00
23 0.92 23.728 23 23.73 0 0.00 0.00 0 0.00
24 0.96 23.024 24 23.02 0 0.00 0.00 0 0.00
25 1.00 22.320 25 22.32 0 0.00 0.00 0 0.00
26 1.04 21.616 26 21.62 0 0.00 0.00 0 0.00
27 1.08 20.912 27 20.91 0 0.00 0.00 0 0.00
28 1.12 20.209 28 20.21 0 0.00 0.00 0 0.00
29 1.16 19.505 29 19.50 0 0.00 0.00 0 0.00
30 1.20 18.801 30 18.80 0 0.00 0.00 0 0.00
31 1.24 18.097 31 18.10 0 0.00 0.00 0 0.00
32 1.28 17.393 32 17.39 0 0.00 0.00 0 0.00
33 1.32 16.689 33 16.69 0 0.00 0.00 0 0.00
34 1.36 15.986 34 15.99 0 0.00 0.00 0 0.00
35 1.40 15.282 35 15.28 0 0.00 0.00 0 0.00
36 1.44 14.578 36 14.58 0 0.00 0.00 0 0.00
37 1.48 13.874 37 13.87 0 0.00 0.00 0 0.00
38 1.52 13.170 38 13.17 0 0.00 0.00 0 0.00
39 1.56 12.467 39 12.47 0 0.00 0.00 0 0.00
40 1.60 11.763 40 11.76 0 0.00 0.00 0 0.00
41 1.64 11.059 41 11.06 0 0.00 0.00 0 0.00
42 1.68 10.355 42 10.36 0 0.00 0.00 0 0.00
43 1.72 9.651 43 9.65 0 0.00 0.00 0 0.00
44 1.76 8.948 44 8.95 0 0.00 0.00 0 0.00
45 1.80 8.244 45 8.24 0 0.00 0.00 0 0.00
46 1.84 7.540 46 7.54 0 0.00 0.00 0 0.00
47 1.88 6.836 47 6.84 0 0.00 0.00 0 0.00
48 1.92 6.132 48 6.13 0 0.00 0.00 0 0.00
49 1.96 5.428 49 5.43 0 0.00 0.00 0 0.00
50 2.00 4.724627 50 4.72 0 0.00 0.00 0 0.00
0.00 0.00 18.56
Project Spreadsheets to BS 8110 etc
Location Grid line 2 DATA FOR DIAGRAMS II
Basement wall design to BS8110:2005 sheet 2 of 2 Made by rc Job No R68
Originated from 'RCC61 Basement Wall.xls' v4.0 2006 TCC Date

MOMENTS SHEARS
MTE2= 0.00 SE2=IF(YY>=(L-'ANALYSIS & STABILITY'!M28),Ka*(q-QS)*(YY-(L-'ANALYSIS & STABILITY'!M28))^(2)/2
YY= 3.875 MTE1= -62.79 -10.84 87.278
MTLG= 0.00 0.00
MTLQ= 0.00 0.00
MTSG= 0.00 0
MTSQ= -9.14 18.77
MTW= -3.06 1.79

UTM= -106.82
-106.82
0 0.00 0 0.00 0.000
1 0.05 0.6737 0.05 MOMENT DIAGRAM 0.674 0.674 0.00 0.00
2 0.11 1.3343 0.11 -25 -20 -15 -10 -5 0 5 10 15 1.334 0.661 0.00 0.00
3 0.16 1.9799 0.16 1.980 0.646 0.00 0.00
4 0.21 2.6086 0.21 ULT. MT (KNM)
2.609 0.629 0.00 0.00
5 0.27 3.2187 0.27 3.219 0.610 0.00 0.00
6 0.32 3.808 0.32 3.808 0.589 0.00 0.00
7 0.37 4.3749 0.37 4.375 0.567 0.00 0.00
8 0.42 4.9175 0.42 4.917 0.543 0.00 0.00
9 0.48 5.4338 0.48 5.434 0.516 0.00 0.00
WALL (M)

10 0.53 5.9219 0.53 5.922 0.488 0.00 0.00


11 0.58 6.3801 0.58 6.380 0.458 0.00 0.00
12 0.64 6.8064 0.64 6.806 0.426 0.00 0.00
13 0.69 7.199 0.69 7.199 0.393 0.00 0.00
14 0.74 7.5559 0.74 7.556 0.357 0.00 0.00
15 0.80 7.8753 0.80 7.875 0.319 0.00 0.00
16 0.85 8.1554 0.85 8.155 0.280 0.00 0.00
17 0.90 8.3942 0.90 8.394 0.239 0.00 0.00
18 0.95 8.5899 0.95 8.590 0.196 0.00 0.00
19 1.01 8.7406 1.01 8.741 0.151 0.00 0.00
20 1.06 8.8444 1.06 8.844 0.104 0.00 0.00
21 1.11 8.8995 1.11 8.899 0.055 0.00 0.00
22 1.17 8.9039 1.17 8.904 0.004 8.90 1.17
23 1.22 8.8558 1.22 8.856 -0.048 0.00 0.00
24 1.27 8.7534 1.27 8.753 -0.102 0.00 0.00
25 1.33 8.5946 1.33 8.595 -0.159 0.00 0.00
26 1.38 8.3778 1.38 8.378 -0.217 0.00 0.00
MOMENT DIAGRAM
27 1.43 8.1009 1.43 8.101 -0.277 0.00 0.00
28 1.48 7.7622 1.48 -25 -20 -15 -10 -5 0 5 10 15 7.762 -0.339 0.00 0.00
29 1.54 7.3597 1.54 7.360 -0.402 0.00 0.00
30 1.59 6.8916 1.59 6.892 -0.468 0.00 0.00
ULT. MT (KNM)
31 1.64 6.3559 1.64 6.356 -0.536 0.00 0.00
32 1.70 5.7509 1.70 5.751 -0.605 0.00 0.00
33 1.75 5.0746 1.75 5.075 -0.676 0.00 0.00
WALL (M)

34 1.80 4.3252 1.80 4.325 -0.749 0.00 0.00


35 1.86 3.5007 1.86 3.501 -0.824 0.00 0.00
36 1.91 2.5994 1.91 2.599 -0.901 0.00 0.00
37 1.96 1.6193 1.96 1.619 -0.980 0.00 0.00
38 2.01 0.5586 2.01 0.559 -1.061 0.00 0.00
39 2.07 -0.5847 2.07 -0.585 -1.143 0.00 0.00
40 2.12 -1.8124 2.12 -1.812 -1.228 0.00 0.00
41 2.17 -3.1263 2.17 -3.126 -1.314 0.00 0.00
42 2.23 -4.5284 2.23 -4.528 -1.402 0.00 0.00
43 2.28 -6.0205 2.28 -6.020 -1.492 0.00 0.00
44 2.33 -7.6045 2.33 -7.604 -1.584 0.00 0.00
45 2.39 -9.2822 2.39 -9.282 -1.678 0.00 0.00
46 2.44 -11.056 2.44 -11.056 -1.773 0.00 0.00
47 2.49 -12.927 2.49 -12.927 -1.871 0.00 0.00
48 2.54 -14.897 2.54 -14.897 -1.970 0.00 0.00
49 2.60 -16.969 2.60 -16.969 -2.072 0.00 0.00
50 2.65 -19.143 2.65 -19.143 -2.175
8.90 1.17

Geometry

0 0
0 400
1E-005 400
1E-005 3000
2000 3000
2000 2700
200 2700
200 3000
200 400
2000 400
2000 0
0 0 3000 2000
Made by rc Job No R68
3-Apr-17

000))))+(B/1000-XX)/(B/1000)*(BP-(VL/

*3))*BP),((VL/(B/1000)*(1-

), ((VL/(B/1000)* (1-6*ABS(ECCY))/

0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0 0.00
0.00
Made by rc Job No R68
3-Apr-17
Project Spreadsheets to BS 8110 etc
Location Grid line 2 CRACK WIDTH CALCULATIONS
Basement wall design to BS8110:2005 Made by rc Job No R68
Originated from 'RCC61 Basement Wall.xls' v4.0 2006 TCC Date 3-Apr-17

WALL
MR= 17.81 MS= 356 Asreq = 432 fs = 89.2929Asprov%= 0.8819
As/bd= 0.009 MSS= 356 Assreq = 215 fs = 44.3819Asprov%= 0.8819
X= 64.60 MSBB= 766 ASBBreq= 0 fs = 4E-015 Asprov%= 0.3808
Ic= 272266479 MSBT= 766 ASBTreq= 168 fs = 34.704 Asprov%= 0.3808
STS= 0.000382
ST1= 0.000592
ST2= 0.00026081
Acr= 81.0449325
W= 0.05
m= 0.0003

MR= 17.81 MR= 17.81


AsBB/bd= 0.0038 AsBT/bd= 0.0038
X= 107.96 X= 107.96
Ic= 1841552107 Ic= 1841552107
STS= 0.0000 STS= 0.0002
ST1= 0.0000 ST1= 0.0002
ST2= 0.00043455 ST2= 0.00043455
Acr= 81.0449325 Acr= 81.0449325
W= -0.08 W= -0.05
m= -0.0004 m= -0.0002
Disclaimer
All advice or information from MPA-The Concrete Centre is intended for those who will evaluate the significance and
limitations of its contents and take responsibility for its use and application. No liability (including that for negligence) for any
loss resulting from such advice or information is accepted by MPA-The Concrete Centre or its subcontractors, suppliers or
advisors. Users should note that all MPA-The Concrete Centre software and publications are subject to revision from time to
time and they should therefore ensure that they are in possession of the latest version.

This spreadsheet should be used in compliance with the accompanying publication 'User Guide RC Spreadsheets: v4'
available from The Concrete Centre www.concretecentre.com/rcdesign Tel +44 (0)1276 606800

Status of spreadsheet This spreadsheet is shareware but may not be used for commercial purposes until the user
Public release version. has registered with The Concrete Centre using the licence validation form available on The
Concrete Centre website www.concretecentre.com/rcdesign

Revision history RCC61 Basement Wall.xls

Date Version Action


1-Apr-10 RCC61 v4.0 Re-badged as TCC/Mineral Products Association.
21-May-09 RCC61 v3.4 Corrupted picture replaced on DATA page.
1-Oct-08 RCC61 v3.3 Reference corrected at DESIGN!I107.
25-Sep-08 RCC61 v3.2 Correction to ST2 values on !Crackwidth.
28-Jun-06 RCC61 v3.1 v3 release. Page nos, User Guide and registration details amended.
12-Nov-05 RCC61 v3.0 Updated to 2005 versions of BS8110 & BS8666
22-Jan-03 RCC61 v2.1 DETR logo replaced by DTI.
11-Oct-02 RCC61 v2.0 Version 2 enhancements
29-May-02 RCC61 v1.4 Data! Main diagram made into jpg
15-Apr-01 RCC61 v1.3 Design section reinforcment summary amended.
20-Jun-00 RCC61 v1.2 Eccy Mt 7 & P-Delta Mt revised (DESIGN!D29:D30)
Crack width w for top of inner base amended.
24-Mar-00 RCC61 v1.1
Notes re crack widths and cracking added.
First public release.
6-Aug-99 RCC61 v1.0
Includes b version comments
aluate the significance and
that for negligence) for any
subcontractors, suppliers or
bject to revision from time to

uide RC Spreadsheets: v4'

cial purposes until the user


tion form available on The
m/rcdesign

Size (kB)
468
462
602
565
565
586
563
591
399
399
399

398

398

Вам также может понравиться