Вы находитесь на странице: 1из 13

RE Wall Summary for Flyover

Chainage (km)
Sl no. TCS Type
From To

1 -0.687 0.000 TCS-2C


2 0.000 0.600 TCS-2B
6 15.350 16.680 TCS-2
9 40.130 41.290 TCS-2
10 56.850 57.206 TCS-2B
11 57.206 57.568 TCS-2D
Total
l Summary for Flyover

Filter
Length Panel Area Sand filling Earth filling
Media
(m) (sqm) (cum) (cum)
(cum)
687 5202 16815 0 2587
600 9034 31805 0 4893
1330 13457 94485 95488 6758
1160 11395 76716 87484 5492
356
362
4495 39087 219820 182972 19730
Filter media Panel Area
behind behind
Avg ht. (m)
Structure Structure
Face Face

44 93 5.00
49 105 6.00
317 571 6.00
253 455 5.50

662 1224
REINFORCED EARTH RETAINING STRUCTURES (FLYOVER APP
BOQ Item
Item Description Unit Nos.
No.
1 RE Wall Facia Panel sqm
-0.687 0.000 TCS-2C
0.000 0.600 TCS-2B
15.350 16.680 TCS-2
40.130 41.290 TCS-2
56.850 57.206 TCS-2B
57.206 57.568 TCS-2D
RE wall panel behind structure face
Total sqm

2 RCC M-40 crash barrier and friction slab Lm

-0.687 0.000 TCS-2C 2.00


0.000 0.600 TCS-2B 2.00
15.350 16.680 TCS-2 2.00
40.130 41.290 TCS-2 2.00
56.850 57.206 TCS-2B 2.00
57.206 57.568 TCS-2D 2.00
Total

3 Filter media behind RE wall/Retaining wall

Filter media behind Structure Face


56.850 57.206 2.00
57.206 57.568 2.00
Total cum

5 Sand filling behind RE wall ( Coarse Sand ) cum From RE Wall

56.850 57.206 1

57.206 57.568 1
Total cum

Filling with approved earth between RE wall/Retaining


6 cum From RE Wa
wall
Total cum
7 Excavation for RE Wall foundation cum 2
Total cum

8 50 mm GI pipe fitted with MS brackets Rmt 2


Total Rmt

9 Sand filling for Gr. Improvement cum 2


Total cum

10 PCC Leveling Pad (M10) cum 2


Total cum

11 PCC below friction slab cum 2


Total cum
12 100 mm dia CI Downtake Pipe m
-0.687 0.000 2
0.000 0.600 2
15.350 16.680 2
40.130 41.290 2
56.850 57.206 2
57.206 57.568 2
Total

Synthetic enamel paints used for


12
concrete barrier sqm
RE Wall Crash Barrier
Total
UCTURES (FLYOVER APPROACH)

Length Width Area Depth Quantity

687.00 5,202
Approach for Flyover at 0.000
600.00 9,034
1330.00 Approach for Flyover at 15.791 13,457
1160.00 Approach for Flyover at 40.772 11,395
356.00 Approach for Flyover 5.00 3,560
362.00 at 57.205 4.00 2,896
1224
46,800

663.00 1,326
462.00 924
1254.00 2,508
1007.00 2,014
296.00 592
362.00 724
8,100

19,730

744
296.00 0.60 3.8 1,364
362.00 0.60 2.8 1,234
23,100

From RE Wall summary sheet 219,820

296 6.8 3.8 7,729


362 6.8 2.8 6,991
234,600

From RE Wall summ sheet 182,972

183,000
4044.00 1 0.5 4044
4,100

4044.00 8088
8,100

4044.00 1 0.3 2426.4


2,500

4044.00 1 0.1 808.8


900

4044.00 1.85 0.15 2,244


2,300
663.00 5.00 185
462.00 6.00 164
1254.00 6.00 428
1007.00 5.50 311
296.00 5.00 87
362.00 4.00 78
1,260

8,100 1.14 9,234


9,300
Item Bill description

7F RE Wall

a) RE Wall Approach Filling Construction of Embankment at


approaches of RE Wall with approved material having properties of
7F.0
C=0 & ?=30 , (Granular material/sand)complete as per technical
specifications .

b)Filling with approved earth from borrow area between RE wall

Providing, casting and erecting of Reinforced Earth retaining wall


using precast concrete fascia panels not less than 180mm thick and of
M35 grade including its design, approval of the same, preparation of
7F.01 working drawings, supply of geogrid, reinforcement, soil reinforcing
element, foundation pad, drainage pipe, water proofing of joints, all
accessories, components and drainage system including ground
improvement compSetem all respects as per drawings.

Providing and laying in position RCC crash barrier M 40 grade with


friction slab, including cost of reinforcement, centering and shuttering
and 2 Nos. 75mni diameter PVC Pipes (duly embedded) with
7F.02
inspection boxes for carrying utilities and Hand Railing complete as
per approved drawings and Technical Specifications Sections 800,
1500, 1700, 2703 and 3100.

7F.03 PCC M-15 below friction slab

7F.04 PCC M-10 Leveling Pad

7F.05 GI pipe including holding fixture complete above RE wall Carsh barrier

Reinforced cement concrete (M 40)Crash Barrier with Friction Slab


7F.06 above RE Wall complete as per drawing and Technical Specification
Sections 1500, 1600, 1700, 2700 and 809 and Clause 2703

7F.07 Excavation for RE Wall foundation


7F.08 Sand filling for Gr. Improvement for RE wall foundation

7F.09 HYSD for Crash barrier and friction slab

Providing and laying Filter material behind facia panels of RE wall


7F.10 complete as per drawing and Technical specifications and as directed
by the Engineer-in-charge.

7F.11 100 mm dia CI Downtake Pipe

7F.12 Synthetic Enamel paint for RCC Crash Barrier on RE Wall


Sub-total Bill-7
Unit BOQ Quantity

Cum 234600

cum 183000

Sqm 46800

Rmt 8100

Cum 2300

Cum 900

Rm 8100

cum

Cum 4100
Cum 2500

Mt

Cum 23100

m 1260

sqm 9300
-7

Вам также может понравиться