Вы находитесь на странице: 1из 7

1

Case Name: black and white pro belayiem.hch


2 LEGENDS
3 Burlington, MA Unit Set: EuroSI
4 USA
Date/Time: Thu Oct 13 11:54:10 2016
5
6
7
HI Design Datasheet
8 HIP1
9 Case 1
10
11
Design1
12
13 Performance
14
15
Summary
16
17
NETWORK COST INDEXES
18
19 Cost Index % of Target

20 Heating (Cost/s) 0.0000 * 0.0000 *


21 Cooling (Cost/s) 2.980e-003 * 100.1 *
22 Operating Cost (Cost/s) 2.980e-003 * 100.1 *
23 Capital Cost (Cost) 1.462e+006 * 86.10 *
24 Total Cost (Cost/s) 1.791e-002 * 88.14 *
25
NETWORK PERFORMANCE
26
27 HEN % of Target

28 Heating (kcal/h) 0.0000 * 0.0000 *


29 Cooling (kcal/h) 1.207e+007 * 100.1 *
30 Number of Units 19.00 * 271.4 *
31 Number of Shells 22.00 * 23.66 *
32 Total Area (m2) 4769 * 108.4 *
33
Heat Exchangers
34
35 Heat Exchanger Cost Index Area Shells Load

36 (Cost) (m2) (kcal/h)

37 2E-8/A 5.399e+004 * 149.7 1 * 9.770e+005

38 E-166 7.384e+004 * 238.5 * 1 * 2.448e+006

39 2E-5/A 7.383e+004 * 238.5 * 1 * 1.144e+006

40 2E-5/G 7.384e+004 * 238.5 * 1 * 1.639e+006

41 2E-2/B 7.384e+004 * 238.5 * 1 * 1.823e+006

42 2E-8/B 2.714e+004 * 46.10 1 * 9.547e+005

43 2E-5/B 8.012e+004 * 268.2 * 1 * 1.369e+006

44 2E-5/C 7.384e+004 * 238.5 * 1 * 1.296e+006

45 2E-5/E 7.384e+004 * 238.5 * 1 * 1.458e+006

46 2E-7/B 1.705e+004 * 15.20 1 * 1.769e+005

47 2E-3/B 5.027e+004 * 134.1 * 1 * 1.397e+006

48 2E-1 8.052e+004 * 270.1 * 1 * 1.605e+006

49 2E-10/A,B 2.894e+005 * 1147 3 * 9.678e+006

50 E-165 7.384e+004 * 238.5 * 1 * 2.008e+006

51 2E-5/F 7.384e+004 * 238.5 * 1 * 1.546e+006

52 2E-5/D 7.384e+004 * 238.5 * 1 * 1.375e+006

53 2E-3/A 7.384e+004 * 238.5 * 1 * 1.382e+006

54 2E-7/A 5.102e+004 * 115.4 2 * 2.819e+005

55 2E-6 7.384e+004 * 238.5 * 1 * 1.738e+006

56 Total 1.462e+006 * 4769 * 22 * 3.430e+007 *


57
Utilities
58
59 Utility Type Cost Index Load % of Target

60 (Cost/s) (kcal/h)

61 cw1 COLD 0.0000 * 0.0000 * 0.0000 *


62 cw2 COLD 2.390e-003 * 9.678e+006 * *** *
63 Aspen Technology Inc. Aspen Energy Analyzer Version V8.2 (28.0.0.8215) Page 1 of 7
Licensed to: LEGENDS * Specified by user.
1
Case Name: black and white pro belayiem.hch
2 LEGENDS
3 Burlington, MA Unit Set: EuroSI
4 USA
Date/Time: Thu Oct 13 11:54:10 2016
5
6
7
HI Design Datasheet
8 HIP1
9 Case 1
10
11
Design1
12
13 Performance
14
15
Utilities
16
17 Utility Type Cost Index Load % of Target

18 (Cost/s) (kcal/h)

19 cw4 COLD 2.357e-004 * 9.547e+005 * *** *


20 cw5 COLD 2.412e-004 * 9.770e+005 * *** *
21 cw3 COLD 4.369e-005 * 1.769e+005 * *** *
22 cw6 COLD 6.961e-005 * 2.819e+005 * *** *
23 Total 2.980e-003 * --- ---
24
25 WorkSheet
26
27 Heat Exchanger Cold Stream Cold T in Tied Cold T out Tied Hot Stream Hot T in Tied Hot T out Tied Load Area Status dT Min Hot dT Min Cold

28 (C) (C) (C) (C) (kcal/h) (m2)

29 2E-8/A cw5 30.00 40.00 Gasoil 97.93 T 55.00 T 9.770e+005 149.7 OK 57.93 25.00

30 E-166 crude oil to desalter 91.89 * 111.8 BPA 240.0 T 197.0 T 2.448e+006 238.5 * OK 128.2 105.1

31 2E-5/A crude oil from desalter 106.5 T 113.8 T Fuel Oil 191.1 T 179.3 T 1.144e+006 238.5 * OK 77.22 72.82

32 2E-5/G crude oil from desalter 159.1 169.6 T Fuel Oil 280.2 T 263.3 T 1.639e+006 238.5 * OK 110.6 104.3

33 2E-2/B crude oil to desalter 38.07 * 52.92 T TPA 165.0 T 87.52 T 1.823e+006 238.5 * OK 112.1 49.45

34 2E-8/B cw4 30.00 40.00 BPA 161.8 T 145.0 T 9.547e+005 46.1 OK 121.8 115.0

35 2E-5/B crude oil from desalter 113.8 T 122.6 T Fuel Oil 205.1 T 191.1 T 1.369e+006 268.2 * OK 82.49 77.22

36 2E-5/C crude oil from desalter 122.6 T 130.9 T Fuel Oil 218.4 T 205.1 T 1.296e+006 238.5 * OK 87.48 82.49

37 2E-5/E crude oil from desalter 139.7 T 149.1 T Fuel Oil 247.5 T 232.5 T 1.458e+006 238.5 * OK 98.39 92.78

38 2E-7/B cw3 30.00 40.00 TPA 87.52 T 80.00 T 1.769e+005 15.2 OK 47.52 50.00

39 2E-3/B crude oil to desalter 64.17 * 75.54 Gasoil 220.0 T 158.6 T 1.397e+006 134.1 * OK 144.5 94.47

40 2E-1 crude oil to desalter 25.00 T 38.07 kerosene 145.0 T 55.68 T 1.605e+006 270.1 * OK 106.9 30.68

41 2E-10/A,B cw2 30.00 40.00 Fuel Oil 179.3 T 80.00 T 9.678e+006 1147.1 OK 139.3 50.00

42 E-165 crude oil to desalter 75.54 * 91.89 BPA 197.0 T 161.8 T 2.008e+006 238.5 * OK 105.1 86.22

43 2E-5/F crude oil from desalter 149.1 T 159.0 Fuel Oil 263.3 T 247.5 T 1.546e+006 238.5 * OK 104.3 98.39

44 2E-5/D crude oil from desalter 130.9 T 139.7 T Fuel Oil 232.5 T 218.4 T 1.375e+006 238.5 * OK 92.78 87.48

45 2E-3/A crude oil to desalter 52.92 T 64.17 Gasoil 158.6 T 97.93 T 1.382e+006 238.5 * OK 94.47 45.01

46 2E-7/A cw6 30.00 40.00 kerosene 55.68 T 40.00 T 2.819e+005 115.4 OK 15.68 10.00

47 2E-6 crude oil from desalter 169.6 T 180.7 T Fuel Oil 298.0 T 280.2 T 1.738e+006 238.5 * OK 117.3 110.6

48
49 Heat Exchangers
50
51
Summary
52
53
ALL HEAT EXCHANGERS
54
55 Heat Exchanger Load Cost Area Shells LMTD HTC F Factor Fouling

56 (kcal/h) (m2) (C) (kJ/h-m2-C)

57 2E-8/A 9.770e+005 5.399e+004 * 149.7 1 * 39.18 733.6 0.9496 0.0000 *


58 E-166 2.448e+006 7.384e+004 * 238.5 * 1 * 116.3 373.4 0.9893 0.0000 *
59 2E-5/A 1.144e+006 7.383e+004 * 238.5 * 1 * 75.00 268.4 0.9974 0.0000 *
60 2E-5/G 1.639e+006 7.384e+004 * 238.5 * 1 * 107.4 268.4 0.9974 0.0000 *
61 2E-2/B 1.823e+006 7.384e+004 * 238.5 * 1 * 76.54 432.9 0.9652 0.0000 *
62 2E-8/B 9.547e+005 2.714e+004 * 46.10 1 * 118.3 733.6 0.9980 0.0000 *
63 Aspen Technology Inc. Aspen Energy Analyzer Version V8.2 (28.0.0.8215) Page 2 of 7
Licensed to: LEGENDS * Specified by user.
1
Case Name: black and white pro belayiem.hch
2 LEGENDS
3 Burlington, MA Unit Set: EuroSI
4 USA
Date/Time: Thu Oct 13 11:54:10 2016
5
6
7
HI Design Datasheet
8 HIP1
9 Case 1
10
11
Design1
12
13 Heat Exchangers
14
15
Summary
16
17
ALL HEAT EXCHANGERS
18
19 Heat Exchanger Load Cost Area Shells LMTD HTC F Factor Fouling

20 (kcal/h) (m2) (C) (kJ/h-m2-C)

21 2E-5/B 1.369e+006 8.012e+004 * 268.2 * 1 * 79.83 268.4 0.9968 0.0000 *


22 2E-5/C 1.296e+006 7.384e+004 * 238.5 * 1 * 84.96 268.4 0.9974 0.0000 *
23 2E-5/E 1.458e+006 7.384e+004 * 238.5 * 1 * 95.56 268.4 0.9974 0.0000 *
24 2E-7/B 1.769e+005 1.705e+004 * 15.20 1 * 48.75 1005 0.9947 0.0000 *
25 2E-3/B 1.397e+006 5.027e+004 * 134.1 * 1 * 117.7 373.4 0.9915 0.0000 *
26 2E-1 1.605e+006 8.052e+004 * 270.1 * 1 * 61.07 432.9 0.9406 0.0000 *
27 2E-10/A,B 9.678e+006 2.894e+005 * 1147 3 * 87.16 414.7 0.9766 0.0000 *
28 E-165 2.008e+006 7.384e+004 * 238.5 * 1 * 95.36 373.4 0.9893 0.0000 *
29 2E-5/F 1.546e+006 7.384e+004 * 238.5 * 1 * 101.3 268.4 0.9974 0.0000 *
30 2E-5/D 1.375e+006 7.384e+004 * 238.5 * 1 * 90.10 268.4 0.9974 0.0000 *
31 2E-3/A 1.382e+006 7.384e+004 * 238.5 * 1 * 66.71 373.4 0.9731 0.0000 *
32 2E-7/A 2.819e+005 5.102e+004 * 115.4 2 * 12.63 1005 0.8057 0.0000 *
33 2E-6 1.738e+006 7.384e+004 * 238.5 * 1 * 113.9 268.4 0.9974 0.0000 *
34 All Heat Exchangers (Continued)

35 Heat Exchanger Hot Stream Hot T in Hot T out Cold Stream Cold T in Cold T out dT Min Hot dT Min Cold

36 (C) (C) (C) (C) (C) (C)

37 2E-8/A Gasoil 97.93 55.00 cw5 30.00 40.00 57.93 25.00

38 E-166 BPA 240.0 197.0 crude oil to desalter 91.89 * 111.8 128.2 105.1

39 2E-5/A Fuel Oil 191.1 179.3 crude oil from desalter 106.5 113.8 77.22 72.82

40 2E-5/G Fuel Oil 280.2 263.3 crude oil from desalter 159.1 169.6 110.6 104.3

41 2E-2/B TPA 165.0 87.52 crude oil to desalter 38.07 * 52.92 112.1 49.45

42 2E-8/B BPA 161.8 145.0 cw4 30.00 40.00 121.8 115.0

43 2E-5/B Fuel Oil 205.1 191.1 crude oil from desalter 113.8 122.6 82.49 77.22

44 2E-5/C Fuel Oil 218.4 205.1 crude oil from desalter 122.6 130.9 87.48 82.49

45 2E-5/E Fuel Oil 247.5 232.5 crude oil from desalter 139.7 149.1 98.39 92.78

46 2E-7/B TPA 87.52 80.00 cw3 30.00 40.00 47.52 50.00

47 2E-3/B Gasoil 220.0 158.6 crude oil to desalter 64.17 * 75.54 144.5 94.47

48 2E-1 kerosene 145.0 55.68 crude oil to desalter 25.00 38.07 106.9 30.68

49 2E-10/A,B Fuel Oil 179.3 80.00 cw2 30.00 40.00 139.3 50.00

50 E-165 BPA 197.0 161.8 crude oil to desalter 75.54 * 91.89 105.1 86.22

51 2E-5/F Fuel Oil 263.3 247.5 crude oil from desalter 149.1 159.0 104.3 98.39

52 2E-5/D Fuel Oil 232.5 218.4 crude oil from desalter 130.9 139.7 92.78 87.48

53 2E-3/A Gasoil 158.6 97.93 crude oil to desalter 52.92 64.17 94.47 45.01

54 2E-7/A kerosene 55.68 40.00 cw6 30.00 40.00 15.68 10.00

55 2E-6 Fuel Oil 298.0 280.2 crude oil from desalter 169.6 180.7 117.3 110.6

56
HEAT EXCHANGERS FOR STREAM: cw1
57
58 Heat Exchanger Load Cost Index Area Shells LMTD HTC T in T out Matched With

59
60
61
62
63 Aspen Technology Inc. Aspen Energy Analyzer Version V8.2 (28.0.0.8215) Page 3 of 7
Licensed to: LEGENDS * Specified by user.
1
Case Name: black and white pro belayiem.hch
2 LEGENDS
3 Burlington, MA Unit Set: EuroSI
4 USA
Date/Time: Thu Oct 13 11:54:10 2016
5
6
7
HI Design Datasheet
8 HIP1
9 Case 1
10
11
Design1
12
13 Heat Exchangers
14
15
Summary
16
17
DRIVING FORCE PLOT
18
19
20
Driving Force Plot
300.0
21
22
23 250.0
24
Hot Temperature (C)

25
200.0
26
27
28 150.0

29
30 100.0
31
32
50.00
33
34
35 0.0000
0.0000 20.00 40.00 60.00 80.00 100.0 120.0 140.0 160.0 180.0 200.0
36
37 Cold Temperature (C)
38
39
40 Targets
41
42 Heating 0.0000 kcal/h * Operating Cost Index 2.978e-003 Cost/s *
43 Cooling 1.206e+007 kcal/h * Capital Cost Index 1.698e+006 Cost *
44 Number of Units 7 * Total Cost Index 2.032e-002 Cost/s *
45 Total Area 4400 m2 *
46
47 Topology Data
48
49
Sub-Networks
50
51 Number of Sub-Networks 2 *
52 Network Number Streams in Network

53 Gasoil
54 crude oil to desalter

55 1 * BPA

56 TPA

kerosene
57
58 Fuel Oil
2 *
59 crude oil from desalter

60
61
62
63 Aspen Technology Inc. Aspen Energy Analyzer Version V8.2 (28.0.0.8215) Page 4 of 7
Licensed to: LEGENDS * Specified by user.
1
Case Name: black and white pro belayiem.hch
2 LEGENDS
3 Burlington, MA Unit Set: EuroSI
4 USA
Date/Time: Thu Oct 13 11:54:10 2016
5
6
7
HI Design Datasheet
8 HIP1
9 Case 1
10
11
Design1
12
13 Topology Data
14
15
Loops
16
17 Independant Loops: 9 * Dependant Loops: 9 *
18 Loop Number Exchangers in Loop
19 2E-3/B
1 *
20 2E-3/A

21 E-166
2 *
22 E-165

23 2E-5/A
3 *
24 2E-5/G

25 2E-5/A
4 *
26 2E-5/B

27 2E-5/A
5 *
28 2E-5/C

29 2E-5/A
6 *
30 2E-5/E

31 2E-5/A
7 *
32 2E-5/F

33 2E-5/A
8 *
34 2E-5/D

35 2E-5/A
9 *
36 2E-6

37
Paths
38
39 Path Number Hot Utility Heat Exchangers in Path Cold Utility
40
41
Utilities
42
43 Utilities in Design Utility Included in Searches for Sub-Nets, Loops and Paths
44 cw1 Not Included

45 cw2 Not Included

46 cw4 Not Included

47 cw5 Not Included

48 cw3 Not Included

49 cw6 Not Included

50
51 Notes
52
53
Design Notes
54
55
56
57
Modification Log
58
59
Heat exchanger E-100 is added manually;Heat exchanger E-101 is added manually;Heat exchanger E-101 is deleted manually;Heat exchanger E-102 is added manually;Heat exchanger E-103 is added manually;Hot side of Heat exchan
60
61
62
63 Aspen Technology Inc. Aspen Energy Analyzer Version V8.2 (28.0.0.8215) Page 5 of 7
Licensed to: LEGENDS * Specified by user.
1
Case Name: black and white pro belayiem.hch
2 LEGENDS
3 Burlington, MA Unit Set: EuroSI
4 USA
Date/Time: Thu Oct 13 11:54:10 2016
5
6
7
HI Design Datasheet
8 HIP1
9 Case 1
10
11
Design1
12
13 Grid Design
14
15 Infeasible HX: 0, HX Not Calculated: 0Unsatisfied Stream:1

16
Cross Pinch
17
18 Pinch

19 Network Cross Pinch Load (kcal/h)

20
21
Heat Exchanger Status
22
23 Degrees of Freedom: 0

24 Heat Exchangers Status

25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
Stream Load Status
45
46 Streams Type Unsatisfied % of Total Total

47 (kcal/h) (kcal/h)

48 crude oil from desalter COLD 1.145e+004 * 9.892e-002 * 1.158e+007 *


49
Network Heating
50
51 Utility Type Cost Index Load % of Target

52
53 Total 0.0000 * 0.0000 * 0.0000 *
54
Network Cooling
55
56 Utility Type Cost Index Load % of Target

57 (Cost/s) (kcal/h)

58 cw1 COLD 0.0000 * 0.0000 * 0.0000 *


59 cw5 COLD 2.412e-004 * 9.770e+005 * *** *
60 cw2 COLD 2.390e-003 * 9.678e+006 * *** *
61 cw6 COLD 6.961e-005 * 2.819e+005 * *** *
62 cw3 COLD 4.369e-005 * 1.769e+005 * *** *
63 Aspen Technology Inc. Aspen Energy Analyzer Version V8.2 (28.0.0.8215) Page 6 of 7
Licensed to: LEGENDS * Specified by user.
1
Case Name: black and white pro belayiem.hch
2 LEGENDS
3 Burlington, MA Unit Set: EuroSI
4 USA
Date/Time: Thu Oct 13 11:54:10 2016
5
6
7
HI Design Datasheet
8 HIP1
9 Case 1
10
11
Design1
12
13 Grid Design
14
15
Network Cooling
16
17 Utility Type Cost Index Load % of Target

18 (Cost/s) (kcal/h)

19 cw4 COLD 2.357e-004 * 9.547e+005 * *** *


20 Total 2.980e-003 * 1.207e+007 * 100.1 *
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63 Aspen Technology Inc. Aspen Energy Analyzer Version V8.2 (28.0.0.8215) Page 7 of 7
Licensed to: LEGENDS * Specified by user.

Вам также может понравиться