8344 1004 Mucosal Drug Products / General Information Second Supplement to USP 39NF 34

8. Palmieri A. Suppository dissolution testing: apparatus design and release of aspirin. Drug Dev Ind Pharm. 1981;7(2):247
259.
2S (USP39)

Add the following:

1029 GOOD DOCUMENTATION GUIDELINES

INTRODUCTION

Purpose

Documentation can be viewed as the foundation of all quality systems because clear, complete, accurate records are essen-
tial to all operations and procedures. This general chapter provides guidelines on good documentation practices for the Good
Manufacturing Practice (GMP)-regulated industries, to be used in the production and control of pharmaceutical products, ac-
tive pharmaceutical ingredients (APIs), excipients, dietary supplements, food ingredients, and medical devices. This chapter
describes the underlying principles of proper documentation for GMP operations to assist the user while working with GMP
activities. These guidelines should be helpful for building the basic foundation of a quality system that will ensure proper docu-
mentation as well as record integrity and control.

Scope

This chapter covers different levels and types of documentation, including paper and electronic records that consist of raw
data, reports, protocols, and procedures related to manufacturing controls and analytical data. The chapter also includes rec-
ommendations on information that should be recorded for various types of GMP documents. Electronic systems should be de-
veloped to meet guidelines described in this chapter.
This chapter does not provide information about all applicable current legal requirements, nor does it affect any applicable
current requirements under GMP regulations.

PRINCIPLES OF GOOD DOCUMENTATION

All steps related to the manufacturing, testing, packing, or holding of pharmaceutical products, APIs, excipients, dietary sup-
plements, food ingredients, and medical devices should be documented.
Good documentation principles for manual or electronic records include the following, as applicable:
Records should be clear, concise, accurate, and legible.
Data entries should be recorded promptly when actions are performed.
Backdating and postdating are not allowed.
All corrections to the original entries should be initialed and dated (or captured within an electronic audit trail), with an
explanation included in cases where the reason for the change is not obvious.
Data entries should be traceable to the person who made the entry.
Uncommon abbreviations and acronyms should be defined.
Controls should be in place to protect the integrity of the records.
In the event that ink may have faded over time (e.g., thermal paper), a copy can be used with verification of its accuracy;
the copy should be initialed and dated.
Notebooks, data sheets, and worksheets should be traceable.
An adequate documentation system is needed to ensure data integrity and availability of current and archived records.
Records should be retained per regulatory requirements and be readable during the retention period.
All pages should be paginated. Attachments (supporting documents) should be paginated with a reference to the parent
document.

DATA COLLECTION AND RECORDING

Formats for data collection and recording include, but are not limited to, the following:
Paper forms, data sheets, and worksheets
Notebooks and logbooks
Instrument printouts

Official from December 1, 2016


Copyright (c) 2017 The United States Pharmacopeial Convention. All rights reserved.
Accessed from 10.6.1.1 by mvpstn3kts on Thu Apr 06 04:48:43 EDT 2017
Second Supplement to USP 39NF 34 General Information / 1029 Good Documentation Guidelines 8345

Electronic data obtained with a system such as an electronic data system, laboratory information management system
(LIMS), or electronic laboratory notebook (ELN)
All data should be permanently recorded directly and legibly when the activity is performed. If it is paper record, then it
should be recorded in indelible ink. All data entries should be traceable to who made the entry and when. Additionally, elec-
tronic records must meet the requirements of the Code of Federal Regulations Title 21 (21 CFR), Part 11.
Any change to an entry should be made in a way that does not obscure the original entry, with an explanation in cases
where the reason for the change is not obvious. Changes should be traceable to who made the change and when the change
was made. For clarity, predefined correction codes may be used, for example, WD = wrong date.
Notebook pages and worksheets should be used consecutively, and information should be recorded chronologically. GMP
records such as batch records, test methods, and specifications should be given unique identifiers and use version control for
the documents.
All data entry fields should be completed. A single line and/or N/A should be drawn through portion(s) of a page that are
not used. If the record is in an electronic system and the system provides traceability of who filled each field and when, the
field can be left blank.
Decimals less than one should be preceded by a zero. Rounding rules and guidelines on significant figures are described in
USPNF General Notices and Requirements.
All dates should be expressed in a format that clearly indicates the day, month, and year.
All GMP records for data collection should undergo appropriate review and signature by a second person to confirm the
accuracy, compliance, and completeness of the entries. Additional signatures may be required on the basis of local Standard
Operating Procedures (SOPs) for different levels of review (e.g., performed by, verified by, checked by, reviewed by, approved
by) as accountability steps.
An official record of signature and initials should exist for each employee or can be contained within the document. Controls
should be in place for assigning signature approval requirements and delegation of signature authority, when needed.
In the event that verified copies of raw data have been prepared, the verified copy may be substituted for the original source
as raw data.
All multiple-page data sheets or instrument printouts in paper form should be signed/initialed on the first or last page with a
note indicating the total number of pages. The first page and all subsequent pages should be uniquely identified to the activity
being performed, such as the notebook reference, study number, or worksheet reference.

DIFFERENT TYPES OF GMP DOCUMENTS

The following or similar documents should include the following information, but are not limited to these items.

Laboratory Records

Laboratory records should be organized to ensure that the records are concise, clear, legible, and accurate, and detail the
following:
Description of materials, such as reagents. This information typically includes the material name, manufacturer and lot
number, titer or concentration, expiration date, grade (if known), and a reference to the lab notebook if prepared in the
lab
Identification of equipment used. This information typically includes equipment name, unique control number, and cali-
bration expiration date, as applicable
Procedures used
Measurements
Formulae and calculations
Results and conclusions

Equipment-Related Documentation

All equipment used in manufacturing, testing, packing, or holding of a raw material, component, API, finished product, or
other similar item should be maintained and qualified for its intended use. The documentation related to equipment includes:
Policies and procedures for operation and maintenance
Equipment use
Maintenance records
Calibration or qualification records
Instrument labeling

Official from December 1, 2016


Copyright (c) 2017 The United States Pharmacopeial Convention. All rights reserved.
Accessed from 10.6.1.1 by mvpstn3kts on Thu Apr 06 04:48:43 EDT 2017
8346 1029 Good Documentation Guidelines / General Information Second Supplement to USP 39NF 34

Deviations and Investigations

All aberrations, anomalies, and exceptions related to manufacturing, testing, packing, or holding of a raw material, compo-
nent, API, finished product, or other similar item should be documented. Once documented, the deviation should be evalu-
ated and investigated, as appropriate. Procedures should be in place for documenting, evaluating, and investigating such
events. Documentation of the investigation should include the following:
Description of the event
Root-cause investigation
Evaluation of data trend
Responsibilities of people involved in the investigation or deviations
Impact assessment
Corrective Action and Preventive Action (CAPA) with timelines
Review and approval

Batch Records

A Master Batch Record (MBR) is created as a template for the manufacture of a specific product. An Executed Batch Record,
based on the MBR, is used to document the steps and materials involved in the production of a specific batch of a raw materi-
al, component, API, finished product, or other similar item. Typically, the following sections are included in a Batch Record,
and should be approved by an appropriate representative from the manufacturing site or packaging site:
Header information (e.g., product name, batch number, manufacturing site)
Unit of operation (e.g., blending, coating, filling)
Manufacturing process
Target weights (raw materials)
Conditions (time, temperature)
Deviations and investigations
In-process sampling or testing
Other critical information, as applicable
Sampling plan for release, stability, and retention
Review and approval

Certificate of Analysis

The purpose of the Certificate of Analysis (C of A or CoA) is to report analytical results for a specific batch of a raw materi-
al, component, API, finished product, or other similar item. Typically, the following sections are included on a C of A and
should be approved by an appropriate representative from the testing site:
Vendor, supplier, or manufacturer information (as applicable)
Product information (name and strength)
Results for the specific batch, with name of test, acceptance criteria, and result for each test
Conformance statement or equivalent
Reference to procedure and specification document
Reference of data source
Approval and date
Expiration date or retest information

Standard Operating Procedures

The purpose of an SOP is to provide directions to trained personnel regarding a given set of activities. SOPs should be clear
and concise. The following sections are typically included in an SOP:
Purpose and scope
Instructions and procedure
Responsibilities and roles
Materials or equipment, as appropriate
Definitions or references, as needed
Review and approval
Revision history

Official from December 1, 2016


Copyright (c) 2017 The United States Pharmacopeial Convention. All rights reserved.
Accessed from 10.6.1.1 by mvpstn3kts on Thu Apr 06 04:48:43 EDT 2017
Second Supplement to USP 39NF 34 General Information / 1029 Good Documentation Guidelines 8347

Protocols and Reports

Many tasks and activities are executed on the basis of a predefined, preapproved protocol. The results of these activities are
then documented in a final report with conclusions. Examples of such activities are as follows:
Equipment qualification
Analytical method validation or verification
Manufacturing process validation
Analytical method or manufacturing technology transfer
Cleaning validation
Stability study or testing
Comparability study
Both the protocol and the report should typically include the following sections:
Purpose
Plan or instructions
Predetermined acceptance criteria
Deviations or investigations, or a reference to (for report only)
Assessment or evaluation (for report only)
Data reference (for report only)
Review and approval
Revision history

Analytical Procedures

Analytical procedures provide direction to an operator on how to perform a given analytical test. The following sections will
typically be included in the analytical procedure:
Purpose
Test information
Product information
Safety information, if applicable
Materials and equipment
Procedure, as applicable
System suitability
Preparation of solutions and reagents
Preparation of standards and samples
Instrument parameters
Calculations and reporting
Review and approval with approval dates
Revision history

Training Documentation

Personnel should be trained to perform their assigned tasks. The training should be documented, and the training records
should be retained and kept readily accessible. In general, training documentation should include:
Training description including name of training, version, and mode (self-training or instructor led)
Completion date
Information on the trainer, as applicable

Retention of Documents

An adequate policy for record retention and archiving should be established for the above records. The required length of
time depends on the regulatory requirements or company procedures; however, it should be at least 1 year after the batch
expiration date.
2S (USP39)

Official from December 1, 2016


Copyright (c) 2017 The United States Pharmacopeial Convention. All rights reserved.
Accessed from 10.6.1.1 by mvpstn3kts on Thu Apr 06 04:48:43 EDT 2017
8348 1063 Shear Cell Methodology / General Information Second Supplement to USP 39NF 34

Add the following:

1063 SHEAR CELL METHODOLOGY FOR POWDER FLOW TESTING

1. INTRODUCTION
1.1 Scope
2. THEORY AND PRINCIPLES
3. DESCRIPTION OF SHEAR CELL COMPONENTS AND DESIGNS
4. SHEAR CELL MEASUREMENTS
4.1 Sample Preparation
4.2 Instrument Preparation
5. SELECTION OF TEST CONDITIONS
6. TEST PROCEDURE
7. DATA ANALYSIS AND CALCULATIONS
8. REFERENCE MATERIALS AND REPRODUCIBILITY

1. INTRODUCTION

A large number of pharmaceutical processes involve powder transfer and feeding, and the ability of powders to flow in a
controlled manner during these operations is critical to product quality. For example, drug product attributes such as weight
and content uniformity depend on powder flow characteristics. Shear cells are among the most important methods for meas-
uring powder flow properties, and the data from shear cell testing can be used to predict a wide variety of powder flow behav-
iors during pharmaceutical manufacturing. Shear cells have many advantages over simpler methods of measuring powder flow
(see Powder Flow 1174), but their operation is more complex and the procedures for their use must be carefully controlled to
produce accurate and reproducible data. This chapter describes best practices for obtaining reliable and accurate powder flow
data using a shear cell.

1.1 Scope

This chapter focuses on the three most popular shear cell types used for measuring powder flow properties:
1. Translational (Jenike type)
2. Annular (Schulze type)
3. Rotational (Peschl type)
These three shear cell types are categorized as direct shear tests in which a region of the powder is sheared under a series of
controlled normal stresses. From these data, a wide variety of parameters can be obtained, including the yield locus represent-
ing the shear-stress to normal-stress relationship at incipient flow, the angle of internal friction, the unconfined yield strength,
powder cohesion, and a variety of related parameters such as the flow function. In addition, these three shear cells can be set
up with wall coupons (see Appendix) to measure the powder wall friction. When the shear cell data are combined, they can be
used for bin and hopper evaluation and design. Other testing approaches, such as triaxial testers and indirect or hybrid testers
(e.g., the Johanson indicizer), are outside the scope of this chapter.

2. THEORY AND PRINCIPLES

The flow behavior of a powder is fundamentally different from the flow of a fluid. First, powder flow properties and shear
behaviors are strongly dependent on the consolidation stresses applied to the powder and are minimally dependent on the
strain or flow rate (under the assumption of quasi-static conditions such as flow in a bin). Fluid flow, in contrast, is strongly
dependent on the strain rate (where viscosity describes the relationship between shear stresses and strain rates) and is mini-
mally dependent on absolute pressure. Second, when shear stresses are applied to powders, they may not immediately fail
(i.e., they can avoid flow under a sustained shear stress), whereas Newtonian and viscoelastic fluids do not behave this way
and always flow under an applied shear stress. Thus, powders have the potential for arching and rat-holing, depending on the
flow pattern (see Appendix).
However, powders can sustain a shear stress without flowing only up to a certain point. The yield locus for a given powder is
a function of many variables, including its composition, particle size and shape, moisture content, temperature, time stored at
rest, and the state of consolidation. Once a powder is subjected to stresses (whether by gravity or some mechanical means)
that reach or exceed the yield locus, the powder flows. Hence, determining the yield locus for a given powder under condi-
tions representative of its manufacturing process is an essential step in evaluating the flow behaviors for that process. In some
circumstances, this may involve testing under controlled environmental conditions, as well as holding the powder under load
for an extended period before shearing (a time test).

Official from December 1, 2016