MIDC DSR is published vide Circular No21 dated 24-07-2013 (DSR 2013-
2014) in which there are various items for concreting works. Under these items for plain
concreting work, under item No.GEN/C-1, an option is made available for using maximum
50% crushed sand. Similarly, in RCC works under item No.GEN/C-3 (a), maximum 50%
crushed sand and for design mix concrete and 100% crushed sand for Ready Mix concrete
items is allowed with the permission of respective CEs. For remaining concreting works,
crushed sand was not allowed.
Due to directives of Hon Court, in some of Districts of the State, extraction
of natural sand is not allowed; as such the natural sand is not easily available for
construction purpose.
The use of crushed sand provisions in BIS are as under,
i) The code of practice of plain and reinforced concrete, IS 456/2000, under
clause 5.30, allows use of crushed sand for the concreting works.
ii) IS 383 of 2016 is for specification for coarse and fine aggregates for
concreting work which also permits use of crushed sand in concreting work and also
specifies its physical and chemical characteristics.
It is expected that; henceforth the availability of natural sand may be
meager and hence use of crushed sand will be inevitable. Under the circumstances,
permission to use 100% crushed sand for concrete works for ongoing and new works shall
be allowed by Chief Engineers only after ascertaining following:
(a) That there is ban on the extraction of natural sand within the District & or in
nearby Districts. Record to that effect shall be maintained.
(b) There is no availability of natural sand at all.
While using 100% crushed sand following guidelines to ensure the quality of
concrete in all cases shall be observed.
Rajendra
Digitally signed by Rajendra V Sonje
DA: Annexure 'A' DN: c=IN, o=Government Of Maharashtra,
ou=Maharashtra Industrial Development
Corporation, postalCode=400093,
st=Maharashtra,
2.5.4.20=d506b9d4018c2e258b65866bb33f52
V Sonje
084ed5d28355acb23fce92c12284d03ddb,
serialNumber=1cd6aae66536d805467ffc44ab
1cb1318aa0893aa1a56213222be21f4023faca,
cn=Rajendra V Sonje
Date: 2016.12.14 17:37:27 +05'30'
Gen/C/1B Add for centering component for loft type Cu.M. Deleted Deleted Deleted Deleted
retaining wall, gravity wall or work
involving major shuttering in the item
Gen/C/1
h) Add for additional centering involved for Cu M 850.00 800.00 800.00 800.00
water retaining structures
Notes :
**********