¢>JOTUN ADHESION PULL OFF TEST . REPORT FOR EXXONMOBIL EXPLORATION & PRODUCTION MALAYSIA INC. GP 29-02-18 DU 37442A BRISTLE BLAST ¢>JOTUN INSPECTION / JOB REPORT PANEL NO. 1 TEST PANEL SYSTEM GP 29-02-18 SYSTEM NO.2 TABLE I} 1) BACKGROUND DATE OF JOD 13 October 2011 — 15" October 2011 PROJECT TITLE ‘Test Panel For GP System OWNER EMEPMI CONTRACTOR ‘Kencana Pinewell Sdn. Bhd. LOCATION (AREA) KSB Phase I NATURE OF JOB “Test Panel ‘SURFACE PREPARATION Bristle Blast 2) AMBIENT CONDITION PARAMETER i” Pad a” COAT coat COAT Date IBA 140/11 ISAO/T Time 1030 Hrs. 1100 Hrs 1100 Hrs Weather ‘Sunny Clear Sunny Conditions Dry Bulb B 30 31 | Deg C Wet Bulb: 28 27 27 Deg C RH % 6 79 B Dew Point 26 6 26 Deg Steel Temp, 37 31 4 (Deg C ¢>JOTUN ADHESION PULL OFF TEST PANEL 1 No: ADH/IMN/O52/11 "TEST METHOD. 150 4624 - 03 PAINTING SYSTEM ¥¥ coat : Resist 76 75umn 29 coat : Jotacote Universal: 150ym. 3 coat : Hardtop Xp 50m te “Test Panel PAINT SYSTEM ‘GP 29-02-18 System No. 2 Table i ‘SUBSTRATE Carbon steel ‘SURFACE PREPARATION Bristle Blast ‘SURFACE CLEANLINESS, 5a 2.5 (150 8501-1) ‘PROJECT “Test Panel For GP System OWNER | ExxonMobil Exploration & Producbon Malaysia Ine. CONTRACTOR ‘kencana Pinewell Sdn, Bhd. LOCATION AREAS: ‘KSB Phase Il, Keaman DOLLY ATTACHMENT (DATE) 1 November 2011 @ 1000 Hrs DOLLY PULLED OFF (DATE) 2 November 2011 @ 1030 Hrs "TVBE OF ADHESIVE USED ‘Araldite Epoxy Glue (Slow Dry Setting) [INSTRUMENT USED. P.A.T Model GM Ot - Series No. 1239 DOLLY DFT um PULL-OFF REMARKS POSITION | BEFORE AFTER RESULTS Spot No.1 |" 372ym | 356ym__{ 1800psi | 100% cohesion on 1 coat ‘Spot Wo.2 | "319ym | ~"302um | —2100psi [100% cohesion on 1* coat Ss Saat sagem | 2400est [aso cohesion on 1° cam 10% glue fatiure Cane Avior Sotan S78 P.VIJENDRAN, COATING sea ine ican mpeg Omer NEPM dJOTUN PHOTOGRAPH ADHESION PULL OFF TEST 1. Overall view before adhesion pull off test conducted. 2. Overall view after adhesion pull off test conducted. ¢>JOTUN ADHESION PULL OFF TEST PANEL 2 ‘Report No: ADH/IMN/053/11 "TEST METHOD. 1S0 4624 - 03 PAINTING SYSTEM 1" coat : Jotacote Universal > 100um 2° coat : Jotacote Universat 150um 3 coat ; Hardtop Xp 2 Soym ITEM. “Test Panel ‘PAINT SYSTEM (GP 29-02-18 System No. 5 ‘SUBSTRATE, Carbon steel ‘SURFACE PREPARATION, Bristle Blast ‘SURFACE CLEANLINESS $32.5 x PROJECT. Test Panel For GP System ‘OWNER ExxonMobil Exploration & Production Malaysia Ine. CONTRACTOR, Kencana Pinewell Sdn, Bhd. LOCATION AREAS KSB Phase IL, Kemaman DOLLY ATTACHMENT (DATE) 1 November 2011 @ 1008s 2™ November 2011 @ 1030Hrs. ‘TYPE OF ADHESIVE USED ‘Araldite Epoxy Giue (Siow Dry Setting) INSTRUMENT USED. P.AT Model GM 01 - Series No. 1239) DOLLY DFT um PULL-OFF REMARKS POSITION | BEFORE AFTER RESULTS ‘SpetNo.t | 315yum | 306ym 2900psi__| 100% cohesion on 1 coat ‘Spot No.2 | 338m _[__312ym 2900psi | 100% cohesion on_i* coat SpotNo:3 | 324ym_|_318ym ‘2900ps\__| 100% cohesion on'1* coat ‘Minimum test requirement: 5 Mpa = 725.2 psi eat ine eau Kenenna Piaeweit ENEPM PHOTOGRAPH ADHESION PULL OFF TEST 4, Overall view after adhesion pull off test conducted. ¢>JOTUN ADHESION PULL OFF TEST Report No: ADH/IMN/O54/11 PANEL 3 TEST METHOD. ‘ASTM D 454i - 02 PAINTING SYSTEM T* coat : Marathon hb F000" 2% coat : Marathon Xhb 1000um 3 coat | Hardtop XP 50m Tre “Test Panel PAINT SYSTEM ‘GP 29-02-18 System No.1 Table Hh ‘SUBSTRATE. ‘Carbon steel ‘SURFACE PREPARATION Bristle Blast ‘SURFACE CLEANLINESS. saz PROJECT ‘Test Panel For GP System ‘OWNER ‘ExxonMobil Exploration & Production Malaysia Ine. CONTRACTOR Kencana Pinewall San. Bhd. ‘LOCATION AREAS: Kencana Pinewell, KSB Phasé II, Kemaman. DOLLY ATTACHMENT (DATE) DOLLY PULLED OFF (DATE) TYPE OF ADHESIVE USED ‘Araldite Epoxy Giue (Siow Dry Setting) INSTRUMENT USED. P.AT Model GH 01 = Series No. 1239 DOLLY DFT pm PULL-OFF REMARKS postTION | BEFORE AFTER RESULTS, ‘Spot No. | 1263ym—| 1238 1000psi__ | 100% glue failure Spot No.2 | 1041um [tO L6ymn 1700psi | 90% glue failure 10% cohesion on 1* coat ‘Spot No.3_| 104m |“ ToTaum | _A7O0psi | 100% glue failure _ Spot Nad ~ - 1300psi__ | 90% glue fatlure __| 10% cohesion on 2"coat 1300psi_— | 100% glue fal 1500psi} 95% glue fetlure 5% cohesion on 2coat Spot No? psi | 100% glue failure: ‘Spot No.8 1300psi__| 100% glue failure ‘Spot No.9 | L 1200psi "| 100% glue failure Minimum test requirement: 5 Mpa = 725.2 psi Prpened Contractor ‘encnma Peel Wimessedé Approved 2 VIJENDRAN ee je. Vie vane {sJOTUN PHOTOGRAPH ADHESION PULL OFF TEST 6. Overall view after adhesion pull off test conducted.

Вам также может понравиться