Вы находитесь на странице: 1из 2

WIND LOAD CALCULATION

(Based on CP3)

BASIC WIND SPEED

Basic wind speed, V = 45 meter/sec

DESIGN WIND SPEED

Design wind speed, Vs = VxS1xS2xS3

Where, S1 = Topographical Factor


= 1

S2 = Ground Roughness/Building Factor


= 0.6 (For ht. 3m & Class B building)

S3 = Statical Factor
= 1

Design wind speed Vs = 45x1x0.6x1


= 27 meter/sec

Dynamic wind pressure, q = 0.613xVs2


= 0.613x272
= 447 N/mm2
= 0.447 kN/mm2

WIND PRESSURE CALCULATION FOR CURVED SHADE

FromCP3 Chapter V: Part2, For monopitch canopies, for solidarity ratio 0,

Maximum wind pressure coeff. = +0.3

Minimum wind pressure coeff. = -0.6

DESIGN WIND PRESSURE

Design wind Pressure = +ve Cpe x q


= 0.3x0.447
= 0.134 kN/m2

Design wind Uplift = -ve Cpe x q


= -0.6x0.447
= 0.268 kN/m2
DESIGN WIND LOAD ON FRAME

Frame spacing = 5.5m c/c

Loading area for each side = (5.5x5.5)/4


= 7.563 m2

Downward Load on each frame = 7.563x0.134


= 1.013 kN

Load as UDL = 1.013/5.5


= 0.184 kN/m

Uplift load on each frame = 7.563x0.268


= 2.027 kN

Load as UDL = 2.027/5.5


= 0.368 kN/m

LOAD CASES

Load case 1 (LC1), Wind Pressure = 0.184 kN/m

Load case-2 (LC2), Wind Uplift = 0.368 kN/m