Академический Документы
Профессиональный Документы
Культура Документы
EXCAVATION
FILLING
Hardcore as specified
D To make up levels not exceeding 250mm thick; average 150mm thick M2 154
CONCRETE WORK
IN-SITU CONCRETE
J In strip footings M3 1
K In column stumps M3 3
L In ground beams M3 21
To Collection
Item Description Unit Quantity Rate Amount
In strip footings
In column stumps
In ground beams
In column stumps
In ground beams
To Collection
Item Description Unit Quantity Rate Amount
Collection
B1/1
B1/2
To Summary
Item Description Unit Quantity Rate Amount
EXCAVATION
FILLING
Hardcore as specified
CONCRETE WORK
IN-SITU CONCRETE
In apron slab
DRAINAGE
DRAINS
PERIMETER DRAIN
To Summary 0
Item Description Unit Quantity Rate Amount
FRAME
CONCRETE WORK
IN-SITU CONCRETE
A In columns M3 6
B In floor beams M3 15
C In roof beams M3 13
In columns
In floor beams
In roof beams
In columns
In floor beams
In roof beams
To Collection 0
Item Description Unit Quantity Rate Amount
FRAME (Contd)
B Horizontal M2 184
C Horizontal M2 157
To Collection 0
Item Description Unit Quantity Rate Amount
Collection
FRAME
B1/5
B1/6
To Summary 0
Item Description Unit Quantity Rate Amount
UPPER FLOOR
CONCRETE WORK
IN-SITU CONCRETE
In floor slab
In floor slab
C Horizontal M2 12
PRECAST CONCRETE
Notes;
If in the opinion of the tenderer, the precast panels may be cast into
smaller/bigger units, he should seek for clarification and approval from
the S. O. All costs in connection with any amendments to the precast xx
The tenderer shall note that all unplastered surfaces to precast concrete
shall be finished smooth.He shall allow for this in his prices accordingly. xx
To Collection 0
Item Description Unit Quantity Rate Amount
To Collection 0
Item Description Unit Quantity Rate Amount
Collection
UPPER FLOOR
B1/8
B1/9
To Summary 0
Item Description Unit Quantity Rate Amount
ROOF
CONCRETE WORK
IN-SITU CONCRETE
A 100mm - 150mm Thick gutter slab including all necessary formwork and M3 4
In roof slab
In plinth
In roof slab
E Horizontal M2 24
ROOFING
Coverings
Underlay
To Collection 0
Item Description Unit Quantity Rate Amount
ROOF (Contd)
ROOFING (Contd)
A 600mm Girth M 38
No. 8 gauge flashings; 150mm lapped joints; fixing with matching clips
B 300mm Girth; one ends dressed over roof covering; other ends fixed to M 45
C 300mm Girth; one ends dressed over roof covering; other ends fixed to M 32
WOODWORK
CARCASSING ITEMS
Strutting
C 50mm x 50mm Timber support; including all necessary plate, bolt and M 14
D 100mm x 50mm Timber support; including all necessary plate, bolt and M 59
COMPOSITE ITEM
Roof trusses
F `PATENTED' Roof trusses for pitch roof with and including all necessary
supports as indicated based on relevant drawings and as specified,
overall area approximately 290m2 (measured flat on plan) including
design, built, supply, erection and fixing in position of trusses ITEM 1
gable end
G Fixed louvred vent including framing and finished complete overall size
1000 mm x 600 mm as per Drawing No HQA(98)A208/ C6 (SBH) / BG2 NO 6
H Fixed louvred vent including framing and finished complete overall size
1400 mm x 900 mm as per Drawing No HQA(98)A208/ C6 (SBH) / 7 NO 1
To Collection 0
Item Description Unit Quantity Rate Amount
ROOF (Contd)
WOODWORK (Contd)
uPVC box gutters and fittings; push fit connector joints; gutterwork and
supports self coloured grey as specified
uPVC pipes and fittings; push fit joints; pipework and supports self
coloured grey as specified; externally
E Laid in position M 15
Sundries
F 100mm Diameter NO 10
NEW WORK
Woodwork
To Collection 0
Item Description Unit Quantity Rate Amount
Collection
ROOF
B1/11
B1/12
B1/13
To Summary 0
Item Description Unit Quantity Rate Amount
STAIRS
CONCRETE WORK
IN-SITU CONCRETE
Staircase
To soffits of staircases
G Horizontal M2 4
H Horizontal M2 2
To riser of staircase
To Collection 0
Item Description Unit Quantity Rate Amount
STAIRS (Contd)
METALWORK
Handrails
STAIRCASE AREA
Tiled Work
'Kempas' timber strip, 50mm x 10mm timber strip with and approved
adhesive on and including 20mm thick cement and sand (1:3) screeded
D Landing slab; level, falls and crossfalls and to slope not exceeding 15
degrees from horizontal M2 4
G 100mm high timber skirting on concrete base with top rounded edge M 13
NEW WORK
Staircase Finishes
To Collection 0
Item Description Unit Quantity Rate Amount
Collection
STAIRS
B1/15
B1/16
To Summary 0
Item Description Unit Quantity Rate Amount
CONCRETE WORK
PRECAST CONCRETE
Decorative capping
Walls
On horizontal surfaces
D 115mm Wide M 68
Walls or partitions
E 150mm Thick M2 4
METALWORK
RAILING
GLAZING
GLASS BLOCKS
Walls or partitions
To Summary 0
Item Description Unit Quantity Rate Amount
CONCRETE WORK
PRECAST CONCRETE
WOODWORK
UNFRAMED FIXING
B 75mm x 13mm M 11
Stops
E 50mm x 18mm M 11
COMPOSITE ITEM
Flush door
IRONMONGERY
Knobset
To Collection 0
Item Description Unit Quantity Rate Amount
WOODWORK (Contd)
Hinges
Door closer/stopper
METALWORK
Mild steel sliding door grille comprising of 30mm x 30mm x 30mm L mild
steel angle framing; 30mm x 30mm mild steel hollow section rib
anchored to wall panel all welded together complete with `Henderson
marathonr' or equivalent sliding grille gear set and complete with flush
Mild steel grille comprising of 12mm x 12mm x 6mm thick mild steel
hollow section framing and filled with 12mm x 4mm thick plat and set
dioganally all welded together equivalent lock-set all as per
Mild steel grille comprising of 12mm x 12mm x 6mm thick mild steel
hollow section framing and filled with 12mm x 4mm thick plat and set
dioganally all welded together as per manufacturer's detail
To Collection 0
Item Description Unit Quantity Rate Amount
METALWORK (Contd)
DOORS
Sliding door consisting of frame, top and bottom track factory infilled with
6mm thick float glass, weatherstrip woolpile and all necessary painting
all as per manufacturer's detail and as per drawing no.
WINDOWS
Casement
F 600mm x 600mm top hung window Type TA14 consisting of top hung
panel each size 600mm x 600mm high; coupling mullion, assembling;
fixing by bolting; fixing with screws complete with matching restrainer NO 4
G 1200mm x 600mm top hung window Type TA15 consisting of top hung
panel each size 600mm x 600mm high; coupling mullion, assembling;
fixing by bolting; fixing with screws complete with matching restrainer NO 1
To Collection 0
Item Description Unit Quantity Rate Amount
METALWORK (Contd)
B 600mm x 1200mm side hung window Type TA1 each size 600mm x
1200mm; coupling mullion, assembling; fixing by bolting; fixing with
screws complete with matching restrainer and latch set and all NO 1
C 2400mm x 1200mm side hung window Type TA16 each size 600mm x
1200mm; coupling mullion, assembling; fixing by bolting; fixing with
screws complete with matching restrainer and latch set and all NO 1
F Fixed louvred window overall size 1500mm wide x 600mm high with and
including approved anti-vermin netting fixed on internal face (Type TR5) NO 4
GLAZING
6mm Thick glass fixed to aluminium frame with and including glazing
strip and silicon topping
G 0.1m2 - 0.5m2 M2 7
H 0.5m2 - 1m2 M2 20
NEW WORK
Woodwork
To Collection 0
Item Description Unit Quantity Rate Amount
Varnish as specified
Metalwork
To Collection 0
Item Description Unit Quantity Rate Amount
Collection
B1/19
B1/20
B1/21
B1/22
B1/23
To Summary 0
Item Description Unit Quantity Rate Amount
INTERNAL WALLS
Walls
On horizontal surfaces
B 115mm Wide M 32
WOODWORK
C 9mm Thick vertically fixed to with and including mild steel plate, bolt
and nuts with finishes complete all as per drawing no. M2 17
To Summary 0
Item Description Unit Quantity Rate Amount
INTERNAL DOORS
CONCRETE WORK
PRECAST CONCRETE
WOODWORK
UNFRAMED FIXING
Stops
C 50mm x 18mm M 5
D 75mm x 13mm M 5
COMPOSITE ITEM
Flush door
To Collection 0
Item Description Unit Quantity Rate Amount
WOODWORK (Contd)
Panelled door
IRONMONGERY
Knobset
Hinges
Door closer/stopper
METALWORK
DOORS
NEW WORK
Woodwork
Metalwork
To Collection 0
Item Description Unit Quantity Rate Amount
Collection
INTERNAL DOORS
B1/26
B1/27
To Summary 0
Item Description Unit Quantity Rate Amount
FLOOR
In situ Finishings
A 20 Thick to apron; level, falls and crossfalls and to slope not exceeding
15 degrees from horizontal; laid to fall M2 21
B Floor; level, falls and crossfalls and to slope not exceeding 15 degrees M2 55
D Floor, level, falls and crossfalls and to slope not exceeding 15 degrees M2 8
F Floor; level, falls and crossfalls and to slope not exceeding 15 degrees M2 7
Accessories
To Summary 0
Item Description Unit Quantity Rate Amount
FLOOR
In situ Finishings
A 20 Thick to floor; level, falls and crossfalls and to slope not exceeding 15
degrees from horizontal M2 2
B Floor; level, falls and crossfalls and to slope not exceeding 15 degrees M2 33
D Floor; level, falls and crossfalls and to slope not exceeding 15 degrees M2 66
F Floor; level, falls and crossfalls and to slope not exceeding 15 degrees M2 19
H Floor, level, falls and crossfalls and to slope not exceeding 15 degrees M2 60
K 100mm High timber skirting on concrete base with top rounded edge M 91
L Floor, level, falls and crossfalls and to slope not exceeding 15 degrees M2 102
To Collection 0
Item Description Unit Quantity Rate Amount
NEW WORK
Woodwork
Varnish as specified
To Collection 0
Item Description Unit Quantity Rate Amount
Collection
B1/30
B1/31
To Summary 0
Item Description Unit Quantity Rate Amount
WOODWORK
CARCASSING ITEMS
CEILING
Ceiling Board
D Linings to ceilings; M2 8
Fibrous Plaster
E Linings to ceilings M2 20
NEW WORK
Ceiling Finishes
Woodwork
To Summary 0
Item Description Unit Quantity Rate Amount
CEILING
Plastering
A 20mm Thick M2 63
Ceiling Board
B Linings to ceilings; M2 22
Fibrous Plaster
D EXTRA OVER for forming 600mm x 600mm access panel and including
all necessary framing NO 1
NEW WORK
Ceiling Finishes
To Summary 0
Item Description Unit Quantity Rate Amount
WALL
Plastering
Tile work
D Tiled to wall M2 30
NEW WORK
Wall Finishes
To Summary 0
Item Description Unit Quantity Rate Amount
WALL
Plastering
Tile work
B Tiled to wall M2 84
NEW WORK
Wall Finishes
To Summary 0
Item Description Unit Quantity Rate Amount
WOODWORK
COMPOSITE ITEM
Fittings
F High level wall hung cabinet; overall size 450mm x 300mm x 450mm
high all as per drawing (TypeG5) NO 1
G High level wall hung cabinet; overall size 450mm x 300mm x 600mm
high all as per drawing (TypeG1) NO 1
H High level wall hung cabinet; overall size 600mm x 300mm x 450mm
high all as per drawing (TypeG6) NO 1
J High level wall hung cabinet; overall size 900mm x 300mm x 450mm
high all as per drawing (TypeG7) NO 1
K High level wall hung cabinet; overall size 900mm x 300mm x 600mm
high all as per drawing (TypeG3) NO 1
L `L' shaped cabinet; overall size 1950mm x 300mm x 450mm high as per
drawing No.HQA (98) A208 / C6 (SBH) PR 1b NO 1
To Summary 0
Item Description Unit Quantity Rate Amount
SANITARY FITTINGS
Supply and fix the following Sanitary Fittings and accessories, including
jointing and connecting to services and soil and waste pipes and making
good all work disturbed; internally
Basin
Water Closet
C Approved back inlet squatting water closet pan in white vitreous china
complete with integral foot treads and loose 'S' trap in vitreous china;
complete with 6 litres mid level cistern (level) and lid in vitreous china
and complete with all necessary internal fittings; bedding pan in concrete
bed and including working or making good floor and wall tiling around. NO 1
Shower
E Approved equivalent complete with arm and hand wall flanged with stop NO 3
Soap Holder
Mirror
Towel Rail
K Screw to wall complete with 600mm x 125mm chrome plated bar, plastic
rail insert and accessories fixing screws and plug NO 4
To Collection 0
Item Description Unit Quantity Rate Amount
A Approved 12mm diameter booster bib tap; bright crome plated with
arrowline metal handle. NO 2
B Approved hand bidet set complete with flexible hose and wall bracket
with arrowline metal handle. NO 4
Water Trough
Floor Trap
BUILDER'S WORK
Stool
TESTING
Sanitary Installation
To Collection 0
Item Description Unit Quantity Rate Amount
Collection
SANITARY FITTINGS
B1/38
B1/39
To Summary 0
Item Description Unit Quantity Rate Amount
PLUMBING INSTALLATION
A Supply pipes and fittings, from and including first stopcock from
incoming mains to water storage tanks to sanitary appliances and scour
and overflow pipes from water storage tanks, including all necessary
excavation, connections with requisite connectors to water storage tank
and sanitary appliances, requisite pipe fittings, stopcock and requisite IT 1
C Waste water, soil and vent pipes with and including all requisite fittings
from sanitary appliances and from floor traps and outlet grating to
connecting manholes or water channel drains including all necessary
excavation, concrete casing around pipework, connections with requisite
connectors to sanitary appliances, requisite openings, requisite to IT 1
h i f fl b d ll l t ll d i N
TESTING
Pipework
D On completion of the plumbing installation test all soil, waste, vent pipes
and cold water piping and make good any defects and leave the whole
in perfect working order to the entire satisfaction of the Superintending it 1
To Summary 0
Item Description Unit Quantity Rate Amount
:Summary
:FRAME
:UPPER FLOOR
:ROOF
:STAIRS
:INTERNAL WALLS
:INTERNAL DOORS
:SANITARY FITTINGS
:PLUMBING INSTALLATION
To Main Summary 0