Вы находитесь на странице: 1из 3

Monitoring using Sets of Angles

Monitoring using Sets of Angles

The Sets of Angles application program can be used to monitor points repeatedly over
a period of time at set time intervals. This quick guide will show how this can be done
by selecting a group of pre-determined points and by surveying the points onsite. For
monitoring pre-determined points you will need to upload the coordinates into a job
prior to commencing this exercise.

Step Instruction Screenshots

To access the sets of angles program select


option 2 from the main menu or press the
PROG button. Then choose Sets of Angles
from the list.
Set the Fixpoint Job and Job to be the same.
(You can load pre-defined monitoring
locations into a separate Fixpoint Job. The
1 observations will then go into the Job.)

The F2 button gives access to the


configuration page, see below

If you havent already done so, press Setup


(F3) to complete a station setup.

The parameters tab of the configuration page


allows for you to set up how the program
will work.
Measure method is the order that points will
be observed. Indicating Face 1 or Face 2
Stop For determines if the program will halt
for all messages to the screen, out of
tolerances messages only or Never.
2 Time Out is the period of time the messages
will be displayed. No time out will require
that the (OK) F4 button be pressed in order
to continue.
Time Monitor Needs to be set to Yes so that
you will be given the option to set start and
end times with time interval for the
monitoring.

The Tolerance tab allows the user to define tolerance values that the observations can
be checked against during running of the program to determine consistency of results.

A log file of the observations can be created use 1200appllog.frt to control the format
of this file.

Leica UK Technical Support Group


Monitoring using Sets of Angles

Step Instruction Screenshots

To monitor pre-determined points select


Manage Points List (1) from the menu.
The list will be empty. Select New (F2)
to create a new list of points.
3 The General tab requests a name for the
points list. Ensure that you set the Auto
survey to Yes. This will enable full
automation of the observations.

Select the Points tab to add points into


the list.
ADD (F2) will cross reference the
selected Fixpoint Job and bring all the
points from their into the list.
ADD1 (F3) will cross reference the
selected Fixpoint Job and bring the
single highlighted point into the job
REMOV (F4) and REM A (shift F4)
4 will remove single points or all points
from the list respectively
When ADD or ADD1 have been
selected you also have the option to key
in New (F2) points or Edit (F3) existing
points.
Once the list is complete press Store
(F1) to save and then Cont (F1) to select
the list for use.

To survey points on site to monitor,


select Measure New Points (3) from the
menu.

5 Set the Point ID and Reflector Height


and the Auto Survey to On.

Ensure you have the correct prism


selected and press Cont (F1)

Sight the prism and press All (F1) to


record the point. You will return to the
Define Points for Set screen. The Pt ID
will have incremented by 1.
Press Cont (F1) to survey more points
or Done (F5) to finish. Upon completing
6 the observation list the instrument will
turn to face 2 and observe the points
again.
Then press Yes (F6) to save the list.
You will now be in List management.
Press Store (F1) to save the list.

Leica UK Technical Support Group


Monitoring using Sets of Angles

Step Instruction Screenshots

To begin monitoring select Measure


Sets (3) from the list.

You will be asked to key in a start and


end date and time along with an
Interval.
7
Stop For is related to messages on the
screen such as Out of tolerance
messages. The Time Out is related to
how long the message will be displayed
for.

Press Cont (F1) to begin the monitoring.


The instrument will wait for the allotted
time to begin observations.
8
Once the monitoring is finished the
program returns to the main menu.

Select Calculate Angles (4) to reduce


9 the observations. You will be given a
summary of the SD for the observations.

Press More (F5) to see more detail on


each set of angles.

Press the Edit (F3) button to see results


10 on individual observations

Similar results are given by selecting


Calculate Distances (5) from the Menu