Академический Документы
Профессиональный Документы
Культура Документы
com
ScienceDirect
International Journal of Pavement Research and Technology xxx (2017) xxxxxx
www.elsevier.com/locate/IJPRT
Received 17 October 2016; received in revised form 22 January 2017; accepted 25 January 2017
Abstract
Pervious concrete pavements are gaining popularity for stormwater management. Therefore, there is an impending need for the devel-
opment of quality control and acceptance specications. In this study, the necessary initial steps are taken towards this goal. The pro-
cedures to conduct fresh and hardened density/porosity (u) and 28-day compressive strength (f 0 c) were evaluated. The proper
methodology for casting specimens in the eld was identied by examining the agreement between the fresh (D) and hardened density
(q). The eect of cylindrical size, and curing methods as combinations of air and moist curing during the four-week period on f 0 c was
studied.
Both cylinder sizes demonstrated comparable values of hardened porosity (u = 16 percent) and hardened density (D = 2.11 kg/m3), as
well as strong linear uD correlations (R2 range 0.600.90). The values of D agree well with those of the fresh density (two percent or less
dierence), which conrmed the suitability of the implemented casting and compaction procedure. Small cylinders presented higher
28-day f 0 c than large cylinders by 7.7 to 19 percent, depending on the curing category. The two-week air followed by two-week moist
curing (2A2 M) method yielded the highest 28-day f 0 c for both specimen sizes, however, longer periods of moist curing did not result
in higher strengths. Cylinders from 1A3M, which were exposed to the longest moist curing, demonstrate the lowest f 0 c. Thermogravimetric
analysis (TGA) conrmed the trends seen in 28-day f 0 c and proved (that) longer moist curing resulted in the loss of CSH and Ca(OH)2.
2017 Production and hosting by Elsevier B.V. on behalf of Chinese Society of Pavement Engineering. This is an open access article under the CC
BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
1. Introduction the surface [1,2]. For sidewalks, reduced icing and therefore
pedestrian slipping, and for parking lots/bike trails and
Pervious concrete pavements (PCP) are permeable pave- light trac streets, reduced hydroplaning and wet weather
ment structures, simultaneously serving stormwater man- accidents are among the additional expected outcomes of
agement and bearing pedestrian/trac loads, depending using PCP [2,3].
on the application. In this pavement system, a 150 PCs prominent characteristic is the high content of
300 mm pervious concrete (PC) layer with a high air void hardened air void, typically ranging between 15 and 25 per-
content is placed on a highly voided stone bed as the base cent of the total volume [2]. Porosity is an essential prop-
layer, to allow for a rapid inltration of runo through the erty of PC, impacting its hydraulic, mechanical and
pavement system rather than allowing it to pond or run on durability characteristics, and is highly dependent on the
mixture design parameters and the method of compaction
[1]. PC mixture design is based on limiting the coarse aggre-
Corresponding author. gate grade to single-sized or grade 9.519 mm, and either
E-mail address: snassiri@wsu.edu (S. Nassiri). completely removing or using a minimal amount of ne
Peer review under responsibility of Chinese Society of Pavement
aggregate for added strength [1]. The end result is a matrix
Engineering.
http://dx.doi.org/10.1016/j.ijprt.2017.01.007
1996-6814/ 2017 Production and hosting by Elsevier B.V. on behalf of Chinese Society of Pavement Engineering.
This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007
2 M. Rangelov et al. / International Journal of Pavement Research and Technology xxx (2017) xxxxxx
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007
M. Rangelov et al. / International Journal of Pavement Research and Technology xxx (2017) xxxxxx 3
typically allowed before demolding of the laboratory applied on the sides, as needed to facilitate casting and
specimens [12,21]. During the in-mold seven-day curing, avoid segregation. A total of 48 small, and 40 large cylin-
the specimens for acceptance testing are either cured in ders were cast on the two paving days.
the eld or in the laboratorys ambient conditions or in a
combination of both. No standardized procedure exists 3.2. Curing and testing
for curing the specimens upon demolding. As such,
normally specimens are continued to air cure until the After casting, the specimens were eld-cured for a dura-
designated testing day. The eect and signicance of moist tion between one and three days [23], then transported to
curing in the development of strength in conventional PCC the laboratory and cured in closed molds in laboratory
is well known [22]. However, our past exploratory conditions at 21C for seven days. Upon demolding at 7-
experiment revealed that placing PC specimens in lime- day age, the hardened density and porosity of each speci-
saturated water bath upon demolding results in the men were determined [15]. In this procedure, the dry weight
dissolving of the paste matrix, and a reduction in 28-day (Md), and the dimensions of the specimens are recorded to
f 0 c of between ve to 27 percent, when compared to air- obtain the dry volume (V). To do so, in addition to two
cured specimens. Therefore, this topic deserves further height measurements, two caliper measurements were
investigation before standard procedures can be developed taken at mid-depth to obtain the diameter. Hardened den-
for 28-day f 0 c acceptance testing of PC. sity (q) was calculated as the ratio of the dry mass to the
volume (Md/V). To characterize porosity, each specimen
was submersed in water for at least 30 minutes, after which
3. Methodology
the submersed mass of each specimen was recorded (MW).
The volume of the solids can be obtained by dividing the
3.1. Materials and sampling
dierence between the dry and submersed weights by the
density of water (qw). Subsequently, porosity (u) is calcu-
Specimens in this study were cast from the State Depart-
lated using Eq. (2):
ment of Transportations PCP placement on a ferry termi-
nals dock on two paving days, June 1st, and June 17th, Md Mw
2016. Mixture design and proportioning are provided in u1 2
qw V
Table 1. The coarse aggregate nominal maximum size
was 9.5 mm, with a specic gravity of 2.73. The mixtures Later, the specimens were cured until 28 days of age. In
density was 2096 kg/m3 according to the mixture design, order to assess the impact of dierent curing methods on
resulting in a target porosity of 20.4 percent. Hydration the strength development, the specimens were cured in air
stabilizer and rheology-modifying admixtures were added and in a fog room complying with ASTM C192 [19]. The
to the mixture in dosages specied in Table 1. One of the duration of air and moist curing was designed to include
purposes of using these admixtures is to provide prolonged four curing categories, as described in Table 2. The four
workable time. categories are four weeks of air curing (4A), three weeks
Specimens were cast from multiple truck loads on the in air and one week moist cured in the fog room
two paving days; the fresh density was rst determined (3A1M), two weeks of air and two weeks of moist curing
for each batch based on ASTM 1688 [14], followed by cast- (2A2M), and nally one week of curing in air, followed
ing small and large cylinders. The required mass of fresh by three weeks of moist curing (1A3M). Table 2 also shows
material placed in every mold was dened based on the the number of cylinders of both sizes designated to each
experimentally determined fresh density on the same batch. curing category. Note that the unequal number of speci-
The material was divided in two and three equal lifts for mens in each curing category is the result of a dierent
small and large cylinders, respectively. The fresh PC was number of cylinders cast on the two paving days. Regard-
compacted using a standard 2.5-kg Proctor hammer with less, a sucient number of specimens are included in each
a 30.5-cm drop. The number of hammer drops was category to allow for meaningful statistical comparisons.
adjusted so that the predetermined mass of the fresh PC After 28 days of curing, the specimens were tested for com-
t in the molds. Additionally, strikes of the mallet was pressive strength.
Compressive strength tests were conducted based on the
procedure in ASTM C39 [17] and ASTM D1633 [18]. The
Table 1 loading rate of 0.24 0.05 MPa/s specied in C39, recom-
PC mixture design and proportioning. mended for conventional PCC results in the failure of the
Material Amount per m3 of PC PC specimens in less than two minutes. Therefore, based
Coarse aggregate [kg] 1716 on the recommendations in D1633 [18], the loading rate
Type I/II Cement [kg] 300 was adjusted to 0.10 0.02 MPa/s to allow for the test
Water [kg] 83 on each specimen to last for about four to ve minutes
Admixtures Hydration stabilizer [g] 1260 and to provide a continuous and no-shock loading during
Rheology-modifying [g] 1224
testing.
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007
4 M. Rangelov et al. / International Journal of Pavement Research and Technology xxx (2017) xxxxxx
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007
M. Rangelov et al. / International Journal of Pavement Research and Technology xxx (2017) xxxxxx 5
(a) 2,250
2,200
2,150
Density [lkg/m3]
2,100
2,050
2,000
1,950
1,900
1,850
1,800
D1B1 D1B2 D2B1 D2B2 D2B3 D2B4
(b) 2,250
2,200
2,150
Density [lkg/m3]
2,100
2,050
2,000
1,950
1,900
1,850
1,800
D1B1 D1B2 D2B1 D2B2 D2B3 D2B4
Fig. 1. Comparison of fresh (D) and hardened density (q), based on casting day 1 or 2 (D1 or D2) and PC sampling batch (B1B5) for (a) small and (b)
large cylinders.
2,250
the lowest f 0 c for both cylinders. It was expected that
2,200 Large cylinders
y = -16.748x + 2378.9 longer moist curing will result in the development of more
R = 0.8965
hydration products and thereby higher f 0 c, however, the
Density [kg/m3]
2,150
2,100
results present a dierent pattern. Cylinders from Category
Small cylinders
y = -13.105x + 2315.7 1A3M, with the longest moist curing, demonstrate the
2,050 R = 0.6023 lowest f 0 c among the moist cured cylinders, the second
2,000 lowest f 0 c was achieved for 3A1M, while 2A2M resulted
in the highest f 0 c. Based on f 0 c results, moist curing
1,950
8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00
improved f 0 c, however only when limited to no longer than
Porosity [%] two weeks. Two weeks of air and two weeks of moist
Small cylinders Large cylinders
curing resulted in the most eective curing, resulting in
the highest f 0 c.
Fig. 2. Linear uq relationship for small and large cylinders. The impact of dierent curing categories on f 0 c were sta-
f 0csmall 1:13 f 0clarge 4 tistically assessed by t-tests (Table 5). Dierences in f 0 c
caused by dierent curing methodologies are not statisti-
Eq. (4) is based on all tested specimens. The correlation cally signicant at 95 percent condence level. Large cylin-
coecient at 1.13 corresponds well with the values found ders show lower p-values comparing to small cylinders,
from literature [20]. Coecient ks was calculated for all indicating the more signicant impact of curing on f 0 c.
curing categories separately and presented in Table 4. The comparison of curing methods 4A and 2A2M for large
cylinders, resulted in a p-value of 0.061, which indicates a
4.2.2. Eect of curing method statistical signicance at 90 percent condence.
Specimens from Category 2A2M demonstrate the high- During the curing period, it was observed that the spec-
est f 0 c for both cylinder sizes, while Category 4A presents imens subjected to moist curing in the fog room presented
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007
6 M. Rangelov et al. / International Journal of Pavement Research and Technology xxx (2017) xxxxxx
26
Small cylinders Large cylinders
24
22
f'c [MPa]
20
18
16
14
12
10
4A 3A1M 2A2M 1A3M
Curing category
Fig. 3. Average 28-day f0 c for small and large PC cylinders for four curing categories.
Table 4
Signicance of eect of cylinder size on 28-day f0 c based on Pearson t-test.
Curing category Specimen size Mean (MPa) STDV (MPa) p-values ks
4A Small 19.2 2.8 0.019 1.19
Large 16.2 2.6
1A3M Small 20.2 3.6 0.024 1.12
Large 18.0 3.6
2A2M Small 20.6 3.2 0.361 1.07
Large 19.2 3.6
3A1M Small 19.9 3.3 0.167 1.18
Large 17.0 1.5
All categories Small 19.9 3.3 0.002 1.13
Large 17.6 3.2
Table 5
Results of Pearson t-test comparing f0 c for dierent curing categories.
Curing category p-values for small cylinders p-values for large cylinders
4A 1A3M 2A2A 3A1M 4A 1A3M 2A2A 3A1M
4A Not applicable (NA) 0.486 0.293 0.603 NA 0.206 0.061 0.449
1A3M 0.486 NA 0.873 0.630 0.206 NA 0.403 0.118
2A2M 0.293 0.873 NA 0.747 0.061 0.403 NA 0.484
3A1M 0.603 0.630 0.747 NA 0.499 0.118 0.484 NA
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007
M. Rangelov et al. / International Journal of Pavement Research and Technology xxx (2017) xxxxxx 7
100
85
80
75
0 100 200 300 400 500 600 700 800 900 1000
Fig. 5. TGA results: weight loss percentage versus temperature for samples from four curing categories.
Table 6
LOI results from TGA test, based on dierent temperature ranges for four curing categories.
Temperature range Cement paste compound LOI (%) based on curing category
4A 3A1M 2A2M 1A3M
100450 C CSH, Aft, Afm 10.75 9.36 8.99 7.52
450600 C Ca(OH)2 4.29 2.96 2.71 2.34
6001000 C CaCO3 5.72 7.71 9.05 7.47
gel, while the second and third peak are associated with the eld/laboratory from fresh pervious concrete (PC) to
decomposition of Ca(OH)2 and CaCO3, respectively. be used in quality control mechanical testing for accep-
Fig. 5 demonstrates the results of TGA represented by tance. Therefore, the study aimed at investigating the
the weight loss for the paste samples from four curing eects of cylinder size (small: 100 by 200 mm versus large:
categories. 150 by 300 mm) on porosity, fresh and hardened density.
To quantify dierent phases of the cement paste, per- Moreover, the impacts of cylinder size and four curing cat-
centage weight loss for the following temperature ranges egories of four weeks of air curing (4A), three weeks of air
was calculated based on the literature [26]: 100450 C and one week of moist curing (3A1M), two weeks of air
for the CSH, ettringite (Aft) and monosulphate (Afm), and two weeks of moist curing (2A2M), and one week of
450600 C for Ca(OH)2, and 6001000 C for CaCO3. air and two weeks of moist curing (1A3M) on PC 28-day
The results in terms of weight loss percentage, typically compressive strength (f 0 c) were examined. The main nd-
referred to as loss on ignition (LOI), are presented in ings are presented below:
Table 6. As seen in Table 6, curing category 4A presents
the highest content of CSH, Aft and Afm and Ca Hardened density of both cylinders agreed with the
(OH)2. Among the three curing categories with moist cur- fresh density determined in the eld (the maximum
ing, the amount of CSH, Aft and Afm and Ca(OH)2 dierence was approximately two percent). The
steadily declines with the extension of the moist curing per- corresponding values of fresh and hardened density
iod. This trend further indicates that prolonged moist cur- suggested the adequacy of the implemented casting
ing may lead to decalcication of CSH gel and and compaction methodology for sampling PC in
dissolution of Ca(OH)2 due to the presence of water and/ the eld for the mixture design tested in this study.
or chemical attack. Ca(OH)2 leaching results in increased However, the eect of dierent mixture design
porosity and drop in strength with more severe eects than parameters, such as aggregate shape and nominal
the eects of CSH decalcication on strength [27,28]. maximum size, cement paste content, water-
Finally, the pattern observed in CaCO3 content determined to-cementitious ratio, and so forth needs to be
by TGA for dierent curing categories follows the same investigated in order to provide a framework for
trend observed previously in f 0 c. Curing categories with PC sampling in the eld.
higher content of CaCO3 present higher f 0 c based on The two cylinder sizes demonstrate comparable values
TGA test results. of average porosity (approximately 16 percent) and
average hardened density (2108 kg/m3). The dierence
5. Conclusions between the porosity and density for the two cylinder
sizes was not found to be statistically signicant. This
An experimental study was conducted to identify the result indicates that either cylinder size can be cast for
proper methodology for casting and curing specimens in evaluation of hardened density.
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007
8 M. Rangelov et al. / International Journal of Pavement Research and Technology xxx (2017) xxxxxx
Small cylinders present higher values of 28-day f 0 c, com- [5] K. C osic, L. Korat, V. Ducman, I. Netinger, Inuence of aggregate
paring to large cylinders by 7.7 to 19 percent, and the type and size on properties of pervious concrete, Constr. Build.
Mater. 78 (2015) 6976.
dierence was found statistically signicant for curing [6] A. Ibrahim, E. Mahmoud, M. Yamin, V.C. Patibandla, Experimental
categories 4A and 1A3M, as well as for all tested speci- study on Portland cement pervious concrete mechanical and hydro-
mens, regardless of the curing category. Curing category logical properties, Constr. Build. Mater. 50 (2014) 524529.
2A2M resulted in the highest f 0 c, while the specimens [7] T.C. Fu, W. Yeih, J.J. Chang, R. Huang, The inuence of aggregate
from curing category 4A had the lowest f 0 c. The f 0 c size and binder material on the properties of pervious concrete, Adv.
Mater. Sci. Eng. (2014)
for Categories 4A and 2A2M was found signicantly [8] B. Rehder, K. Banh, N. Neithalath, Fracture behavior of pervious
dierent at 90 percent condence interval for large cylin- concretes: The eects of pore structure and bers, Eng. Fract. Mech.
ders. All other curing categories resulted in statistically 118 (2014) 116.
similar f 0 c. [9] J.T. Kevern, D. Biddle, Q. Cao, Eects of macrosynthetic bers on
Cement paste samples from all four curing categories pervious concrete properties, J. Mater. Civ. Eng. 27 (9) (2014)
06014031.
were examined by TGA, and it was observed that longer [10] Q. Dong, H. Wu, B. Huang, X. Shu, K. Wang, Investigation into
moist curing leads to more loss of CSH and Ca(OH)2. laboratory abrasion test methods for pervious concrete, J. Mater. Civ.
The curing categories characterized by higher values of Eng. 25 (7) (2012) 886892.
f 0 c presented higher quantities of CaCO3, based on [11] J.T. Kevern, K. Wang, V.R. Schaefer, The eect of aggregate type on
TGA results. the freeze-thaw durability of pervious concrete, Adv Perv. Concr.
Technol. 19 (2008).
The observations from this study suggest that both [12] A. Bonicelli, F. Giustozzi, M. Crispino, Experimental study on the
cylinder sizes can be used for quality control tests of pervi- eects of ne sand addition on dierentially compacted pervious
concrete, Constr. Build. Mater. 91 (2015) 102110.
ous concrete. To obtain 28-day f 0 c for large cylinders based [13] M. Rangelov, S. Nassiri, L. Haselbach, K. Englund, Using carbon
on the test results of small cylinders, a correlation factor of ber composites for reinforcing pervious concrete, Constr. Build.
1.13 can be applied. In terms of curing categories, air cur- Mater. 126 (2016) 875885.
ing resulted in a relatively low standard deviation in f 0 c, [14] ASTM, C1688/C1688-M, Standard Test Method for Density and
and minimal CSH and Ca(OH)2 loss. However, for the Void Content of Freshly Mixed Pervious Concrete, ASTM Interna-
tional, West Conshohocken, PA, 2014. DOI: 10.1520/C1688-14.
tested mixture design, two weeks of air and two weeks of [15] ASTM, C1754/C1754M-12, Standard Test Method for Density and
moist curing yielded the highest f 0 c, and a comparatively Air Void Content of Pervious Concrete, ASTM International, West
low standard deviation, hence the latter curing method Conshohocken, PA, 2012. DOI: 10.1520/C1754_C1754M-12.
can be adopted for quality control strength testing of PC. [16] ASTM, C1701/C1701M-09, Standard Test Method for Inltration
In order to validate the recommendations proposed Rate of In Place 1 Pervious Concrete, ASTM International, West
Conshohocken, PA, 2009, DOI: 2 10.1520/C1701_C1701M-09.
herein, future research should include testing of a variety [17] ASTM, C39/C39M-05, Standard Test Method for Compressive
of PC mixtures. Based on the results of this study, future Strength of Cylindrical Concrete Specimens, ASTM International,
assessment of the weight loss in the PC paste caused by West Conshohocken, PA, 2005. DOI: 10.1520/C0039_C0039M-
the prolonged exposure to moist curing is necessary, espe- 05E01.
cially considering the extended exposure of the PC pave- [18] ASTM D1633/D1633-M, 2007, Standard Test Methods for Com-
pressive Strength of Molded Soil-Cement Cylinders, ASTM Interna-
ments to runo. The ndings from this study can serve as tional, West Conshohocken, PA, 2016. DOI: 10.1630/D1630-07.
a guidance for future research to test a variety of commonly [19] ASTM, C192/C192M-15, Standard Practice for Making and Curing
used PC mixtures in preparation for the development of Concrete Test Specimens in the Laboratory, ASTM International,
standard procedures for PC sampling, curing, and testing. West Conshohocken, PA, 2015. DOI: 2 10.1520/C0192_C0192M-15.
[20] D. Vandegrift, A. Schindler, The eect of test cylinder size on the
compressive strength of sulfur capped concrete specimens. Highway
Acknowledgements Research Center and Department of Civil Engineering at Auburn
University, 2006. p. 83.
Authors would like to express their gratitude to XXX [21] L. Haselbach, C. Poor, J. Tilson, Dissolved zinc and copper retention
State Department of Transportation for the funding pro- from stormwater runo in ordinary portland cement pervious
vided for this study and their close cooperation in the eld. concrete, Constr. Build. Mater. 53 (2014) 652657.
[22] P.-C. Aitcin, B. Miao, W.D. Cook, D. Mitchell, Eects of size and
curing on cylinder compressive strength of normal and high-strength
References concrete, Mater. J. 91 (4) (1994) 349355.
[23] ASTM, C31/C31-M, 2012, Standard Practice for Making and Curing
[1] ACI. 522R10. Report on Pervious Concrete ACI Committee 522 Concrete Test Specimens in the Field, ASTM International, West
(2010), 38. Conshohocken, PA, 2015. DOI: 10.1520/C0031-12.
[2] B. Eisenberg, K.C. Lindow, D.R. Smith, Permeable Pavements, [24] NRMCA, Pervious in Practice: Methods, Materials and Mixtures,
ASCE, 2015. National Ready Mixed Concrete Association (NRMCA), Silver
[3] V. Schaefer, J. Kevern, B. Izevbekhai, K. Wang, H. Cutler, P. Spring, MD, www.nrmca.org.
Wiegand, Construction and performance of pervious concrete overlay [25] PD Tennis, ML Leming, DJ Akers, National ready mixed concrete A,
at Minnesota Road Research Project, Transp. Res. Rec. 2164 (2010) Pervious Concrete Pavements, Portland Cement Association Skokie,
8288. IL, 2004.
[4] E. Lim, K.H. Tan, T.F. Fwa, Eect of mix proportion on strength [26] A. Bajza, I. Rousekova, Eect of heat treatment conditions on the
and permeability of pervious concrete for use in pavement, J.Eastern pore structure of cement mortars, Cem. Concr. Res. 13 (5) (1983)
Asia Soc. Transp. Stud. 10 (2013) 15651575. 747750.
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007
M. Rangelov et al. / International Journal of Pavement Research and Technology xxx (2017) xxxxxx 9
[27] C. Carde, R. Francois, J.-M. Torrenti, Leaching of both calcium [28] C. Carde, R. Francois, Eect of the leaching of calcium hydroxide
hydroxide and CSH from cement paste: modeling the mechanical from cement paste on mechanical and physical properties, Cem.
behavior, Cem. Concr. Res. 26 (8) (1996) 12571268. Concr. Res. 27 (4) (1997) 539550.
Please cite this article in press as: M. Rangelov et al., Quality evaluation tests for pervious concrete pavements placement, Int. J. Pavement Res. Technol.
(2017), http://dx.doi.org/10.1016/j.ijprt.2017.01.007