Вы находитесь на странице: 1из 38

TABLA DE RECOLECCIN DE DATOS

DATOS DE LA PRCTICA 4
Configuracin de la bomba al 80%

No Velocidad Caudal Temperatura Pr. Pr. Velocidad Velocidad Densidad Z Torque


. (RPM) (lps) (C) Entrada Salida de entrada de salida del agua (Nm)
(m)
H1 (kPa) H2 (m/s) (m/s) (kg/m3)
(kPa)
1 1200 0.95703 29.6 -1.3 13.5 2.206 3.979 996 0.07 0.566
5
2 1200 0.87695 29.6 -0.5 17.9 2.022 3.646 996 0.07 0.521
5
3 1200 0.78320 29.7 0.2 22.3 1.806 3.256 996 0.07 0.523
5
4 1200 0.67773 29.2 1.1 27.1 1.563 2.818 996 0.07 0.502
5
5 1200 0.59766 29.4 1.8 30.2 1.378 2.485 996 0.07 0.507
5
6 1200 0.51758 29.4 2.4 33.5 1.193 2.152 996 0.07 0.499
5
7 1200 0.41211 29.8 2.7 35.9 0.950 1.713 996 0.07 0.464
5
8 1200 0.33203 30.0 3.0 37.3 0.766 1.380 996 0.07 0.461
5
9 1200 0.23828 29.9 3.4 38.9 0.549 0.991 996 0.07 0.448
5
10 1200 0.13281 30.1 3.6 40.2 0.306 0.552 996 0.07 0.462
5
11 1200 0.06641 30.3 3.7 41.8 0.153 0.276 996 0.07 0.410
5
12 1200 0.00000 30.0 3.7 42.3 0.000 0.000 996 0.07 0.414
5

Configuracin de la bomba al 90%

No Velocidad Caudal Temperatura Pr. Pr. Velocidad Velocidad Densidad Z Torque


. (RPM) (lps) (C) Entrada Salida de entrada de salida del agua (Nm)
(m)
H1 (kPa) H2 (m/s) (m/s) (kg/m3)
(kPa)
1 1350 1.06250 28.5 -2.8 15.7 2.450 4.417 996 0.07 0.538
5
2 1350 0.94336 28.6 -1.6 23.2 2.175 3.922 996 0.07 0.516
5
3 1350 0.86328 28.8 -0.8 27.5 1.990 3.589 996 0.07 0.527
5
4 1350 0.75781 28.8 0.4 32.5 1.747 3.151 996 0.07 0.507
5
5 1350 0.67773 28.9 1.4 36.5 1.563 2.818 996 0.07 0.495
5
6 1350 0.58398 28.9 1.8 40.3 1.346 2.428 996 0.07 0.471
5
7 1350 0.49219 28.9 2.4 43.3 1.135 2.046 996 0.07 0.441
5
8 1350 0.39844 28.5 2.9 46.2 0.919 1.657 996 0.07 0.442
5
9 1350 0.30469 29.0 3.1 48.0 0.702 1.267 996 0.07 0.425
5
10 1350 0.19922 29.2 3.4 49.3 0.459 0.828 996 0.07 0.433
5
11 1350 0.10547 29.1 3.7 51.2 0.243 0.438 996 0.07 0.397
5
12 1350 0.00000 29.1 3.6 52.3 0.000 0.000 996 0.07 0.376
5
DATOS DE LA PRCTICA 6
Configuracin de la bomba al 80%

No Velocidad Caudal Temperatura Pr. Pr. Velocidad Velocidad Densidad Z Torque


. (RPM) (lps) (C) Entrada Salida de entrada de salida del agua (Nm)
(m)
H1 (kPa) H2 (m/s) (m/s) (kg/m3)
(kPa)
1 1200 0.95703 28.8 -1.4 15.1 2.206 3.979 996 0.07 0.496
5
2 1200 0.87695 28.8 -7.0 13.0 2.022 3.646 996 0.07 0.496
5
3 1200 0.79688 28.8 -12.4 11.4 1.837 3.313 996 0.07 0.507
5
4 1200 0.69141 29.0 -18.4 10.0 1.594 2.875 996 0.07 0.501
5
5 1200 0.59766 29.0 -22.6 7.8 1.378 2.485 996 0.07 0.532
5
6 1200 0.50391 29.4 -25.9 6.7 1.162 2.095 996 0.07 0.485
5
7 1200 0.41211 29.1 -28.8 5.7 0.950 1.713 996 0.07 0.487
5
8 1200 0.33203 29.2 -30.8 4.8 0.766 1.380 996 0.07 0.484
5
9 1200 0.25195 29.1 -32.9 4.6 0.581 1.047 996 0.07 0.441
5
10 1200 0.16016 29.3 -34.2 3.9 0.369 0.666 996 0.07 0.420
5
11 1200 0.05273 29.3 -35.2 3.6 0.122 0.219 996 0.07 0.427
5
12 1200 0.00000 29.4 -36.5 3.4 0.000 0.000 996 0.07 0.419
5

Configuracin de la bomba al 90%

No Velocidad Caudal Temperatura Pr. Pr. Velocidad Velocidad Densidad Z Torque


. (RPM) (lps) (C) Entrada Salida de entrada de salida del agua (Nm)
(m)
H1 (kPa) H2 (m/s) (m/s) (kg/m3)
(kPa)
1 1350 1.07617 27.4 -3.0 17.9 2.481 4.474 996 0.07 0.501
5
2 1350 0.98242 27.6 -8.2 16.2 2.265 4.084 996 0.07 0.506
5
3 1350 0.87695 27.7 -16.3 13.8 2.022 3.646 996 0.07 0.467
5
4 1350 0.78320 27.7 -23.5 11.1 1.806 3.256 996 0.07 0.496
5
5 1350 0.67773 27.7 -29.4 9.7 1.563 2.818 996 0.07 0.464
5
6 1350 0.58398 27.7 -32.6 8.1 1.346 2.428 996 0.07 0.445
5
7 1350 0.47852 27.7 -37.0 6.4 1.103 1.989 996 0.07 0.433
5
8 1350 0.39844 28.1 -40.0 4.8 0.919 1.657 996 0.07 0.427
5
9 1350 0.27930 28.2 -43.1 3.5 0.644 1.161 996 0.07 0.428
5
10 1350 0.18555 27.8 -44.0 4.0 0.428 0.771 996 0.07 0.397
5
11 1350 0.10547 27.9 -41.8 3.5 0.243 0.438 996 0.07 0.379
5
FORMULAS A UTILIZAR

1. Carga de la Bomba
H= Z + P+ V

Donde:
Z : Carga de Elevacin=0.075 m.
P2 P 1
P : Carga esttica, en mts; .

V 22V 12
V : Carga de Velocidad, en mts. .
2g

2. Potencia Mecnica
Pot M =

Donde:
: Torque (N-m).
: Velocidad angular (rad/seg).

3. Potencia Hidrulica
Pot H =HQ

Donde:
H : Carga de la bomba (m).

m3
Q : Caudal (
s ).
N
: Peso especifico del agua (
m3 ).

4. Eficiencia
Pot H
= 100
Pot M

Donde:
Pot H : Potencia hidrulica.

Pot M : Potencia mecnica.

4. Carga neta positiva de succin


CNPS=H atm H vap H + H v

Donde:
H atm : Presin atmosfrica expresada en mca.

H vap : Presin de vapor de agua a la mxima temperatura esperada en mca.

H : Presin de succin (Este valor es relativo a la presin atmosfrica y bajo

algunas condiciones puede ser negativo).


H v : Carga de velocidad (m).
CLCULOS
Con los datos de la prctica cuatro se van a calcular la carga neta positiva de
succin disponible. Y con los datos de la prctica seis se van a calcular la carga
neta positiva de succin requerida. Ademas de los datos de la prctica seis se van
a calcular la carga de la bomba, la potencia hidrulica, la potencia mecnica y la
eficiencia.

Configuracin de la bomba al 80%

CARGA DE LA BOMBA
#1

( 15.1(1.4 ) )1000 3.9792 2.2062


H 1=0.075+ +
9969.81 29.81

H 1=2.32 m

#2

( 13.0(7.0) )1000 3.646 22.0222


H 2=0.075+ +
9969.81 29.81

H 2=2.59 m

#3

( 11.4(12.4 ) )1000 3.313 21.8372


H 3=0.075+ +
9969.81 29.81

H 3=2.90 m

#4

( 10(18.4))1000 2.87521.5942
H 4 =0.075+ +
9969.81 29.81

H 4 =3.27 m
#5

( 7.8(22.6) )1000 2.48521.3782


H 5=0.075+ +
9969.81 29.81

H 5=3.40 m

#6

( 6.7(25.9) )1000 2.09521.1622


H 6=0.075+ +
9969.81 29.81

H 6=3.57 m

#7

( 5.7(28.8) )1000 1.71320.9502


H 7=0.075+ +
9969.81 29.81

H 7=3.71 m

#8

( 4.8(30.8) )1000 1.38020.766 2


H 8=0.075+ +
9969.81 29.81

H 8=3.79 m

#9

( 4.6(32.9) )1000 1.04720.5812


H 9=0.075+ +
9969.81 29.81

H 9=3.95 m

# 10

( 3.9(34.2) )1000 0.66620.3692


H 10=0.075+ +
9969.81 29.81
H 10=3.99 m

# 11

( 3.6(35.2) )1000 0.21920.1222


H 11=0.075+ +
9969.81 29.81

H 11=4.05 m

# 12

( 3.4(36.5) )1000 0202


H 12=0.075+ +
9969.81 29.81

H 12=4.16 m

POTENCIA MECNICA
#1

rev

( )
2 rad
min
1 min
1 rev
Pot M1 =( 0.496 Nm ) 1200
60 s

Pot M1 =62.3 watts

#2

rev

( )
2 rad
min
1 min
1 rev
Pot M2 =( 0.496 Nm ) 1200
60 s

Pot M2 =62.3 watts

#3
rev

( )
2 rad
min
1min
1 rev
Pot M3 =( 0.507 Nm) 1200
60 s

Pot M3 =63.7 watts

#4

rev

( )
2 rad
min
1min
1 rev
Pot M 4=( 0.501 Nm) 1200
60 s

Pot M 4=63.0 watts

#5

rev

( )
2 rad
min
1 min
1 rev
Pot M5 =( 0.532 Nm ) 1200
60 s

Pot M5 =66.9 watts

#6

rev

( )
2 rad
min
1 min
1 rev
Pot M6 =( 0.485 Nm) 1200
60 s

Pot M6 =60.9 watts

#7
rev

( )
2 rad
min
1min
1 rev
Pot M7 =( 0.487 Nm) 1200
60 s

Pot M7 =61.2 watts

#8

rev

( )
2 rad
min
1 min
1 rev
Pot M 8=( 0.484 Nm ) 1200
60 s

Pot M 8=60.8 watts

#9

rev

( )
2 rad
min
1 min
1 rev
Pot M 9=( 0.441 Nm ) 1200
60 s

Pot M 9=55.4 watts

# 10

rev

( )
2 rad
min
1 min
1 rev
Pot M10 =( 0.420 Nm ) 1200
60 s

Pot M10 =52.8 watts

# 11
rev

( )
2 rad
min
1 min
1 rev
Pot M11 =( 0.427 Nm ) 1200
60 s

Pot M11 =53.7 watts

# 12

rev

( )
2 rad
min
1 min
1rev
Pot M12 = ( 0.419 Nm ) 1200
60 s

Pot M12 =52.7 watts

POTENCIA HIDRULICA
#1

2.320.95703
Pot H1= 9770.76
1000

Pot H1=21.7 watts

#2

2.590.87695
Pot H2 = 9770.76
1000

Pot H2 =22.2 watts

#3

2.900.79688
Pot H3 = 9770.76
1000
Pot H3 =22.6 watts

#4

3.270.69141
Pot H 4= 9770.76
1000

Pot H 4=22.1 watts

#5

3.400.59766
Pot H5 = 9770.76
1000

Pot H5 =19.9 watts

#6

3.570.50391
Pot H6 = 9770.76
1000

Pot H6 =17.6 watts

#7

3.710.41211
Pot H7 = 9770.76
1000

Pot H7 =14.9 watts

#8

3.790.33203
Pot H8 = 9770.76
1000

Pot H8 =12.3 watts

#9
3.950.25195
Pot H 9= 9770.76
1000

Pot H 9=9.7 watts

# 10

3.990.16016
Pot H10= 9770.76
1000

Pot H10=6.2 watts

# 11

4.050.05273
Pot H11 = 9770.76
1000

Pot H11 =2.1 watts

# 12

4.160.00000
Pot H12= 9770.76
1000

Pot H12=0 watts

EFICIENCIA
#1

21.7
1 = 100
62.3

1=34.8

#2
22.2
2 = 100
62.3

2=35.6

#3

22.6
3 = 100
63.7

3=35.5

#4

22.1
4 = 100
63.0

4 =35.1

#5

19.9
5 = 100
66.9

5=29.7

#6

17.6
6 = 100
60.9

6=28.9

#7

14.9
7 = 100
61.2

7=24.3
#8

12.3
8 = 100
60.8

8=20.2

#9

9.7
9 = 100
55.4

9=17.5

# 10

6.2
10= 100
52.8

10=11.7

# 11

2.1
11 = 100
53.7

11 =3.9

# 12

0
12= 100
52.7

12=0

Configuracin de la bomba al 90%

CARGA DE LA BOMBA
#1

( 17.9(3) )1000 4.47422.4812


H 1=0.075+ +
9969.81 29.81

H 1=2.92 m

#2

( 16.2(8.2) )1000 4.084 22.2652


H 2=0.075+ +
9969.81 29.81

H 2=3.16 m

#3

( 13.8(16.3))1000 3.646 22.0222


H 3=0.075+ +
9969.81 29.81

H 3=3.62 m

#4

( 11.1(23.5) )1000 3.25621.806 2


H 4 =0.075+ +
9969.81 29.81

H 4 =3.99 m

#5

( 9.7(29.4) )1000 2.8182 1.5632


H 5=0.075+ +
9969.81 29.81

H 5=4.36 m

#6

( 8.1(32.6) )1000 2.42821.3462


H 6=0.075+ +
9969.81 29.81
H 6=4.45 m

#7

( 6.4(37) )1000 1.98921.1032


H 7=0.075+ +
9969.81 29.81

H 7=4.66 m

#8

( 4.8(40) )1000 1.657 20.9192


H 8=0.075+ +
9969.81 29.81

H 8=4.76 m

#9

( 3.5(43.1) )1000 1.16120.6442


H 9=0.075+ +
9969.81 29.81

H 9=4.89 m

# 10

( 4(44) )1000 0.77120.428 2


H 10=0.075+ +
9969.81 29.81

H 10=5.01 m

# 11

( 3.5(41.8) )1000 0.4382 0.2432


H 11=0.075+ +
9969.81 29.81

H 11=4.72 m
POTENCIA MECNICA
#1

rev

( )
2 rad
min
1 min
1rev
Pot M1 =( 0.501 Nm ) 1350
60 s

Pot M1 =70.8 watts

#2

rev

( )
2 rad
min
1 min
1 rev
Pot M2 =( 0.506 Nm ) 1350
60 s

Pot M2 =71.5 watts

#3

rev

( )
2 rad
min
1min
1 rev
Pot M3 =( 0.467 Nm) 1350
60 s

Pot M3 =66.0 watts

#4

rev

( )
2 rad
min
1 min
1rev
Pot M 4=( 0.496 Nm ) 1350
60 s

Pot M 4=70.1 watts

#5
rev

( )
2 rad
min
1 min
1 rev
Pot M5 =( 0.464 Nm ) 1350
60 s

Pot M5 =65.6 watts

#6

rev

( )
2 rad
min
1 min
1 rev
Pot M6 =( 0.445 Nm) 1350
60 s

Pot M6 =62.9 watts

#7

rev

( )
2 rad
min
1 min
1 rev
Pot M7 =( 0.443 Nm ) 1350
60 s

Pot M7 =61.2 watts

#8

rev

( )
2 rad
min
1min
1 rev
Pot M 8=( 0.427 Nm) 1350
60 s

Pot M 8=60.4 watts

#9
rev

( )
2 rad
min
1 min
1 rev
Pot M 9=( 0.428 Nm) 1350
60 s

Pot M 9=60.5 watts

# 10

rev

( )
2 rad
min
1 min
1 rev
Pot M10 =( 0.397 Nm ) 1350
60 s

Pot M10 =56.1watts

# 11

rev

( )
2 rad
min
1min
1 rev
Pot M11 =( 0.379 Nm) 1350
60 s

Pot M11 =53.6 watts

POTENCIA HIDRULICA
#1

2.921.07617
Pot H1= 9770.76
1000

Pot H1=30.7 watts

#2
3.160.98242
Pot H2 = 9770.76
1000

Pot H2 =30.3 watts

#3

3.620.87695
Pot H3 = 9770.76
1000

Pot H3 =31.1 watts

#4

3.990.78320
Pot H 4= 9770.76
1000

Pot H 4=30.5 watts

#5

4.360.67773
Pot H5 = 9770.76
1000

Pot H5 =28.9 watts

#6

4.450.58398
Pot H6 = 9770.76
1000

Pot H6 =25.4 watts

#7

4.660.47852
Pot H7 = 9770.76
1000

Pot H7 =21.8 watts


#8

4.760.39844
Pot H8 = 9770.76
1000

Pot H8 =18.5 watts

#9

4.890.27930
Pot H 9= 9770.76
1000

Pot H 9=4.89 watts

# 10

5.010.18555
Pot H10= 9770.76
1000

Pot H10=9.1 watts

# 11

4.720.10547
Pot H11 = 9770.76
1000

Pot H11 =4.9 watts

EFICIENCIA
#1

30.7
1 = 100
70.8

1=43.4

#2
30.3
2 = 100
71.5

2=42.4

#3

31.1
3 = 100
66.0

3=47.1

#4

30.5
4 = 100
70.1

4 =43.5

#5

28.9
5 = 100
65.6

5=44.1

#6

25.4
6 = 100
62.9

6=40.4

#7

21.8
7 = 100
61.2

7=35.6
#8

18.5
8 = 100
60.4

8=30.6

#9

13.3
9 = 100
60.5

9=22.0

# 10

9.1
10= 100
56.1

10=16.2

# 11

4.9
11 = 100
53.6

11 =9.1

CARGA NETA POSITIVA DE SUCCIN DISPONIBLE


La presin atmosfrica se trabajo con un promedio, este dato fue tomado de la
caracterizacin climtica del departamento de Managua publicado el 11 de
diciembre 2008 por la direccin de aplicaciones de la meteorologa de INETER,
siendo este de 1003.9 hpa este valor se convirti a mca al igual que la presin en
la entrada, dado que esta est en pa. Para la presin de vapor se considero la
temperatura mostrada en la tabla de datos y se indago la presin de vapor a
diferentes temperaturas y se interpolo el valor requerido para esta prctica.
Configuracin de la bomba al 80%

#1

1.3 2.2062
CNPS d1=10.2330.432+ +
9.81 19.62

CNPS d1=9.92 m

#2

0.5 2.0222
CNPS d2=10.2330.432+ +
9.81 19.62

CNPS d2=9.96 m

#3

0.2 1.8062
CNPS d3=10.2330.435+ +
9.81 19.62

CNPS d3=9.98 m

#4

1.1 1.5632
CNPS d4 =10.2330.423+ +
9.81 19.62

CNPS d4 =10.05 m

#5
2
1.8 1.378
CNPS d5=10.2330.428+ +
9.81 19.62

CNPS d5=10.09 m

#6
2
2.4 1.193
CNPS d6=10.2330.428+ +
9.81 19.62

CNPS d6=10.12 m

#7

2.7 0.952
CNPS d7=10.2330.437+ +
9.81 19.62

CNPS d7=10.12 m

#8

3 0.7662
CNPS d8=10.2330.442+ +
9.81 19.62

CNPS d8=10.13 m

#9

3.4 0.549 2
CNPS d9=10.2330.44+ +
9.81 19.62

CNPS d9=10.16 m

# 10

3.6 0.3062
CNPS d10=10.2330.444+ +
9.81 19.62

CNPS d10=10.16 m

# 11
2
3.7 0.153
CNPS d11=10.2330.449+ +
9.81 19.62
CNPS d11=10.16 m

# 12

3.7 02
CNPS d12=10.2330.442+ +
9.81 19.62

CNPS d12=10.17 m

Configuracin de la bomba al 90%

#1

2.8 2.452
CNPS d1=10.2330.406+ +
9.81 19.62

CNPS d1=9.85 m

#2

1.6 2.1752
CNPS d2=10.2330.408+ +
9.81 19.62

CNPS d2=9.90 m

#3
2
0.8 1.99
CNPS d3=10.2330.413+ +
9.81 19.62

CNPS d3=9.94 m

#4
2
0.4 1.747
CNPS d4 =10.2330.413+ +
9.81 19.62
CNPS d4 =10.02m

#5

1.4 1.5632
CNPS d5=10.2330.416+ +
9.81 19.62

CNPS d5=10.08 m

#6

1.8 1.3462
CNPS d6=10.2330.416+ +
9.81 19.62

CNPS d6=10.09 m

#7
2
2.4 1.135
CNPS d7=10.2330.416+ +
9.81 19.62

CNPS d7=10.13 m

#8

2.9 0.9192
CNPS d8=10.2330.406+ +
9.81 19.62

CNPS d8=10.17 m

#9
2
3.1 0.702
CNPS d9=10.2330.418+ +
9.81 19.62

CNPS d9=10.16 m

# 10
2
3.4 0.459
CNPS d10=10.2330.423+ +
9.81 19.62

CNPS d10=10.17 m

# 11

3.7 0.2432
CNPS d11=10.2330.420+ +
9.81 19.62

CNPS d11=10.19 m

# 12

3.6 02
CNPS d12=10.2330.420+ +
9.81 19.62

CNPS d12=10.18 m

CARGA NETA POSITIVA DE SUCCIN REQUERIDA


La presin atmosfrica se trabajo con un promedio, este dato fue tomado de la
caracterizacin climtica del departamento de Managua publicado el 11 de
diciembre 2008 por la Direccin de Aplicaciones de la Meteorologa de INETER,
siendo este de 1003.9 hpa este valor se convirti a mca al igual que la presin en
la entrada, dado que esta est en pa. Para la presin de vapor se considero la
temperatura mostrada en la tabla de datos y se indago la presin de vapor a
diferentes temperaturas y se interpolo el valor requerido para esta prctica.

Configuracin de la bomba al 80%

#1

1.4 2.2062
CNPSr 1=10.2330.413+ +
9.81 19.62
CNPSr 1=9.93 m

#2

7 2.0222
CNPSr 2=10.2330.413+ +
9.81 19.62

CNPSr 2=9.31 m

#3

12.4 1.8372
CNPSr 3=10.2330.413+ +
9.81 19.62

CNPSr 3=8.73 m

#4
2
18.4 1.594
CNPSr 4=10.2330.418+ +
9.81 19.62

CNPSr 4=8.07 m

#5

22.6 1.378 2
CNPSr 5=10.2330.418+ +
9.81 19.62

CNPSr 5=7.61 m

#6
2
25.9 1.162
CNPSr 6=10.2330.428+ +
9.81 19.62

CNPSr 6=7.23 m

#7
2
28.8 0.95
CNPSr 7=10.2330.42+ +
9.81 19.62

CNPSr 7=6.92 m

#8

30.8 0.7662
CNPSr 8=10.2330.423+ +
9.81 19.62

CNPSr 8=6.70 m

#9

32.9 0.5812
CNPSr 9=10.2330.420+ +
9.81 19.62

CNPSr 9=6.48 m

# 10

34.2 0.3692
CNPSr 10=10.2330.425+ +
9.81 19.62

CNPSr 10=6.33 m

# 11

35.2 0.1222
CNPSr 11=10.2330.425+ +
9.81 19.62

CNPSr 11=6.22 m

# 12
2
36.5 0
CNPSr 12=10.2330.428+ +
9.81 19.62
CNPSr 12=6.08 m

Configuracin de la bomba al 90%

#1

3 2.4812
CNPSr 1=10.2330.38+ +
9.81 19.62

CNPSr 1=9.86 m

#2

8.2 2.2652
CNPSr 2=10.2330.384+ +
9.81 19.62

CNPSr 2=9.27 m

#3

16.3 2.0222
CNPSr 3=10.2330.387+ +
9.81 19.62

CNPSr 3=8.39 m

#4
2
23.5 1.806
CNPSr 4=10.2330.387+ +
9.81 19.62

CNPSr 4=7.62 m

#5
2
29.4 1.563
CNPSr 5=10.2330.387+ +
9.81 19.62
CNPSr 5=6.97 m

#6

32.6 1.3462
CNPSr 6=10.2330.387+ +
9.81 19.62

CNPSr 6=6.62 m

#7

37 1.1032
CNPSr 7=10.2330.387+ +
9.81 19.62

CNPSr 7=6.14 m

#8
2
40 0.919
CNPSr 8=10.2330.396+ +
9.81 19.62

CNPSr 8=5.80 m

#9

43.1 0.6442
CNPSr 9=10.2330.399+ +
9.81 19.62

CNPSr 9=5.46 m

# 10
2
44 0.428
CNPSr 10=10.2330.389+ +
9.81 19.62

CNPSr 10=5.37 m

# 11
2
41.8 0.243
CNPSr 11=10.2330.392+ +
9.81 19.62

CNPSr 11=5.58

TABLA DE PRESENTACIN DE RESULTADOS


Configuracin de la bomba al 80%

N Carga H Pot. Mecnica Pot. Hidrulica Eficiencia


. (m) (Watts) (Watts)
(%)
1 2.32 62.3 21.7 34.8
2 2.59 62.3 22.2 35.6
3 2.90 63.7 22.6 35.5
4 3.27 63.0 22.1 35.1
5 3.40 66.9 19.9 29.7
6 3.57 60.9 17.6 28.9
7 3.71 61.2 14.9 24.3
8 3.79 60.8 12.3 20.2
9 3.95 55.4 9.7 17.5
10 3.99 52.8 6.2 11.7
11 4.05 53.7 2.1 3.9
12 4.16 52.7 0.0 0.0

Configuracin de la bomba al 90%

N Carga H Pot. Mecnica Pot. Hidrulica Eficiencia


. (m) (Watts) (Watts)
(%)
1 2.92 70.8 30.7 43.4
2 3.16 71.5 30.3 42.4
3 3.62 66.0 31.1 47.1
4 3.99 70.1 30.5 43.5
5 4.36 65.6 28.9 44.1
6 4.45 62.9 25.4 40.4
7 4.66 61.2 21.8 35.6
8 4.76 60.4 18.5 30.6
9 4.89 60.5 13.3 22.0
10 5.01 56.1 9.1 16.2
11 4.72 53.6 4.9 9.1

Carga neta positiva de succin

Configuracin de la bomba al 80 %
N Disponible Requerida
1 9.92 9.93
2 9.96 9.31
3 9.98 8.73
4 10.05 8.07
5 10.09 7.61
6 10.12 7.23
7 10.12 6.92
8 10.13 6.70
9 10.16 6.48
10 10.16 6.33
11 10.16 6.22
12 10.17 6.08

Configuracin de la bomba al 90%


N Disponible Requerida
1 9.85 9.86
2 9.90 9.27
3 9.94 8.39
4 10.02 7.62
5 10.08 6.97
6 10.09 6.62
7 10.13 6.14
8 10.17 5.80
9 10.16 5.46
10 10.17 5.37
11 10.19 5.58
12 10.18