1.

Boiler design Data


Hull no. Type Customer Date
1453/4 MC065P04 Hyundai Heavy Industries Co., Ltd. 03-10-9

Boiler design data

1. Technical data

Steam production for oil-fired section : 1200 kg/hr


Steam production for exh. gas section : 1200 kg/hr
2
Working pressure (Design press.) : 6 (8) kg/cm G
Feed water temperature 85
Ambient temperature : 45
Fuel oil consumption : 89 kg/hr
Boiler back pressure ( at furnace) : 70 mmH2O
Fuel gas outlet temperature : abt. 370

Dimension

Diameter exclude insulation : 2900 mm


Height excl. of mounting, include uptake : 4680 mm
3
Steam volume at normal water level : 1.25 m
3
Water volume at normal water level : 10.9 m
Weight of boiler (dry) approx : 17.9 ton
Exh. gas inlet/outlet size : 1200/1200 A

Classification

Hull No. 1453/4 : DNV

Exh. gas data

Engine load ISO(NCR) ISO(MCR) SUM(NCR)SUM(MCR) WIN(NCR) WIN(MCR)


Exh. gas amount (kg/h) 123000 135200 114500 125900 124500 136900
Steam production (kg/h) 1200 1322 1802 1984 870 982
Exh. gas inlet temp. () 227.7 230 264.8 267.1 210.6 212.9
Exh. gas outlet temp. () 206 208 229 231 195 197
Exh. gas draft loss (mmAq) Max. 120 mmAq

Painting color

Boiler body : Heat resist paint


Control panel : Munsell 7.5 BG 7/2