OPERATING CHANGING THE SETPOINT MANUAL DEFROST CYCLE

1. Turn unit On/Off Switch "on". 1. Turn unit On/Off switch "on".
THE THERMOGUARD
TG-VI 2. Press Up and Down Arrow keys to chose
the new setpoint.
2. Press the Select key to display [dEF].

MICROPROCESSOR 3. Press the Enter key. The display will


3. Press the Enter key. The display will briefly show [Lod], and then the unit will
briefly show [Lod], and then the new setpoint enter a defrost cycle. The defrost cycle will
will reappear. terminate automatically.

THERMOGUARD VI
TEMPERATURE SELECTING CYCLE SENTRY OR VIEWING PROMPT & DISPLAY
COOL
CYCLE
SENTRY CONTINUOUS MODE ON UNITS SCREENS
HEAT ! ALARM
EQUIPPED WITH CYCLE SENTRY 1. Turn unit On/Off switch "on".
DEFROST ELECTRIC
1. Turn unit On/Off switch "on".
SETPOINT
2. Press the Select key to view the prompt
2. Press the Select key to display [CYCLS] and display screens as follows:
and [YES] or [nO].
[Alr] Alarm codes if any
3. Press the Up or Down Arrow key to [dEF] Defrost prompt
select the desired mode. [YES] = Cycle [CYCLS] Cycle Sentry prompt (not on
Sentry, [nO] = Continuous. units without Cycle Sentry)
[dIS] Discharge air temperature
4. Press the Enter key. The display will [tLH] Total unit hours
SELECT SETPOINT ENTER
briefly show [Lod], and then the new mode [EnH] Diesel engine hours
will reappear. [ELH] Electric hours
[Hr4] Hourmeter 4 if enabled
[Hr5] Hourmeter 5 if enabled
[Hr6] Hourmeter 6 if enabled
STARTING THE ENGINE ON UNITS
[oIL] Engine oil pressure
ON
EQUIPPED WITH CYCLE SENTRY [EnT] Engine coolant temperature
1. Turn the unit On/Off switch "on". If no [rPn] Engine RPM
other key is pressed, the engine will [bAt] Battery voltage
OFF
automatically preheat and start in about 10 [CoL] Evaporator coil temperature
seconds. [dFI] Initial defrost interval
Used on: [ddr] Defrost duration
CAUTION: The engine starts automatically
SB-III MAX+ in either Cycle Sentry or Continuous mode.
Super-II MAX+
TK 41086
TG-VI ALARM CODES
VIEWING & CLEARING ALARM 00 No fault
UNITS NOT EQUIPPED WITH
CODES 02 Evaporator coil sensor CYCLE SENTRY
1. Turn unit On/Off Switch "on". 03 Return air sensor
04 Discharge air sensor Units not equipped with Cycle Sentry have a
2. If the Alarm Icon is "on", alarm conditions 06 Engine water temp sensor Preheat/Start switch.
have been detected 07 Engine RPM sensor
08 Unit controlling on coil sensor
09 High evaporator temp
3. Press the Select key. The Alarm Screen 10 High discharge pressure ON START
and alarm code will appear. If more than 11 Unit controlling on discharge air sensor
one alarm is present, each will be displayed 12 Sensor shutdown
OFF PREHEAT
for several seconds. Always record any 16 Manual start not completed
alarm codes shown. They are invaluable to 17 Engine failed to crank
the service technician. 18 High engine water temp
19 Low engine oil pressure Press the switch to "Preheat" to energize the
4. After the alarm condition has been 20 Engine failed to start glow plugs to preheat the engine. For
21 Cooling cycle check
corrected, press the Select key to display temperatures from 32F to 0F preheat the
22 Heating cycle check
the alarm code. When the alarm code is 23 Cooling cycle fault engine for 30 seconds. For temperatures
shown in the display, press the Enter key to 24 Heating cycle fault below 0F preheat the engine for 60
clear the alarm. 25 Alternator check seconds. Press the switch to "Start" to
28 Unit Self Check abort crank the engine.
31 Oil pressure sensor
RUNNING A UNIT SELF CHECK 32 Refrigeration capacity low
33 Check engine RPM
1. Turn unit On/Off switch "on".
34 Check modulation circuit
35 Run Relay circuit ADDITIONAL INFORMATION
2. The engine must be running. Clear any 36 Electric motor failed to run
alarm codes that may exist. 37 Check engine water level For additional information consult the
38 Electric phase reversed following Thermo King manuals for your
3. Press and hold the Thermo King Logo 40 High speed circuit unit.
key for at least 3 seconds. The Unit Self 52 Heat circuit
Check prompt screen will appear. 54 Test Mode timeout
61 Battery check Operating Manual
63 Engine stopped - reason unknown
4. Press the Enter key to start a Unit Self Maintenance Manual
66 Low engine oil level
Check test. The display will briefly show 70 Hourmeters exceed 99999
[Lod] and the test will begin. 71 Hourmeter 4 exceeds set limit Parts Manual
72 Hourmeter 5 exceeds set limit
5. The test is fully automatic. When 73 Hourmeter 6 exceeds set limit TG-VI Operation and Diagnosis Manual
complete, [PASS], [CHEC] or [FAIL] will 74 Microprocessor reverted to default settings TK 41017
appear on the display. 77 Internal fault code, dealer resettable