Академический Документы
Профессиональный Документы
Культура Документы
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
The growing demand for The CYME Long-Term Dynamics The module also allows the
Analysis module offers a study of reserve capability of
renewable sources of clean time-series simulation tool to any battery energy storage
energy has significantly study the impact of irradiance device.
increased the presence variations, wind fluctuations
and load variations on network Sun Radiation, Wind Speed
of wind and solar power controls such as regulators, and Load Profile
supplies for power load tap changers and switched
A curve library is included in
capacitors, and on the behavior
generation portfolios. of battery energy storage
the CYME software to allow
Utilities are now facing the user to create their own
devices.
long-term dynamics curve
the challenge of managing models along with generation
Long-Term Dynamics
variable sources of energy Analysis for Distributed Energy
curve models and motor
interconnections to the grid. curve models. The Long-term
Resources
Dynamics Analysis module uses
To prepare for increased The intermittency of wind and the following curves:
penetration levels and to cloud-over periods alters the Insolation
output of wind energy systems
plan the deployment of and photovoltaic (PV) generation. Wind speed
Distributed Generation By analyzing the impact of such
variations on regulators, load
Load
Resources (DER), new
tap changers and capacitor Generation
simulation tools are needed. switching, the Long-Term
Dynamics Analysis allows power
Motor
engineers to properly assess
the impact of DER integration
and to better understand related
technical issues such as var
control and voltage regulation.
Long-Term Accurate Equipment Modeling
Detailed distributed generator
The presence of battery energy
storage systems has increased
to support the importance of
Time-based simulation results
are illustrated in comprehensive
graphs. Reports are available
models, such as wind energy
Dynamics conversion systems (WECS), are
available. The CYME software
DER integration and to allow
peak-shaving.
for device controls such as
regulator tap changers, and for
the penetration level of each
features a detailed PV system The energy storage model takes
Analysis model for which the output
function is represented by
into account of charge and
discharge delays, and features
type of distributed generation
in the network. Detailed reports
and charts are also available
manufacturer data such as: the following controls:
for monitored devices. Power
Insolation curve model No monitoring: time driven engineers can easily evaluate
Study the impact of and load shape modes the performance of the system
irradiance variations, wind Current at maximum point with or without DER, determine
Power monitoring: power
fluctuations and load Voltage at maximum point
driven, power peak shaving,
the impact of different DER
locations and evaluate the effect
variations on network Evaluating System Impact
power following, power of different variable profiles.
controls. levelling modes
With the Long-Term Dynamics The Long Term Dynamics
DER monitoring: DER driven, Analysis module is a powerful
Analysis module, time-series
DER levelling, DER support tool to evaluate solar array and
simulations can be performed
and DER smoothing modes wind farm impacts on the power
to assess how the DER output
profile affects: system, preparing the network
for tomorrows higher DER
Voltage regulators penetration levels.
Load tap changers
Capacitors
The user can specify the
activation time delay, tap
changer delay and mechanism
delay data of the regulators and
LTCs tap changing algorithm in
order to prevent unnecessary
switching due to voltage
fluctuations. Time delays are also
available for shunt capacitors
and switchable shunt banks
to specify closing and tripping
delays. The user also has the
option to start the analysis at
any moment in time (other
than zero) in order to include
time-controlled capacitors in the
analysis.
Voltage regulators have four
reset modes: fast, induction
disc, delay and delay freeze
reset.
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
The global trend for cleaner As the landscape of the This productivity tool saves labor The accurate results provided
distribution system evolves with time by allowing engineers to by the CYME Integration
power, supported by the the rapid emergence of new run simulations without the use Capacity Analysis are a key
arrival of new technologies renewable energy technologies, of manual tools. A minimum to support utilities in their
such as solar and wind electric distribution utilities number of parameters, such current and future generation
are challenged to accelerate as the maximum capacity to interconnection request
farms as well as affordable DER deployment and process consider and the peak and processing. Moreover, the
rooftop photovoltaic panels, interconnection requests in a minimum load conditions, are powerful reporting capabilities
timely manner. required before the assessment of the CYME software make it
has changed the distribution can be performed on a the perfect tool for publishing
system landscape. The The CYME Integration Capacity
complete or partial model of color-coded hosting capacity
Analysis module comes in handy
ever-increasing volume of to efficiently and consistently
the distribution system. The circuit maps for customers
maximum hosting capacity is and developers interested
distributed energy resources calculate the maximum
determined based on a set in suitable locations for DER
(DER) interconnection generation or load capacity that
of user-defined thresholds interconnection projects.
can be installed independently
requests creates a need referring to a list of criteria that
at each point of a distribution
includes thermal overloads,
for new innovative system without adversely
reverse power flow, abnormal
impacting its reliability and
engineering tools. The power quality.
steady-state voltages, transient
CYME Integration Capacity voltage variations (flicker),
reduction of protection reach
Analysis module allows and sympathetic tripping.
performing an assessment
of the generation or load
hosting capacity of a
distribution system without
compromising its reliability
and power quality.
Integration The CYME Integration Capacity
Analysis module calculates the
maximum generation or load
Illustrative results
Integration capacity analysis
results are displayed in a tabular
Capacity capacity at each point of the
distribution circuits analyzed.
report detailing the maximum
hosting capacity at each node
of the circuits analyzed. Results
Analysis Features
The analysis uses an iterative
for each individual constraint are
also provided.
method which considers:
Results can of course be used
Integration of generation or to color-code the one-line
load up to a user-defined diagram or feed the color map
Create comprehensive maximum capacity value function in order to graphically
color-coded hosting capacity emphasize locations with greater
Maximum fault contribution
circuit maps using the CYME for generation integration,
or lesser integration capacity.
Integration Capacity Analysis or customer type for load
module. integration
Load scaling factors or load
models for peak and minimum
load conditions
Customizable load flow
and short-circuit calculation
parameters
System reliability and power
quality are ensured by a series
of criteria-based verifications
including:
Thermal loading of monitored
devices based on user-defined
limits set by device type
Reverse flow through ICA results in the CYME software
monitored devices based on
a maximum permissible user-
defined value
Abnormal steady-state
voltages based on user-
defined over- and under-
voltage limits applicable
globally or by voltage range
(LV, MV, HV)
Voltage variations caused by
sudden generation or load
fluctuations based on a user-
defined limit
Reduction of protection
reach of monitored devices
considering pickup security
factor
Sympathetic tripping of
monitored devices considering
security factor
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com
Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com