Вы находитесь на странице: 1из 8

CYME

Power Engineering Software and Solutions

Distribution System Analysis

Reliable analytic and planning tools to


improve electrical network performance
The Distribution System The CYME power engineering Major features Fault analysis:
software features a powerful
Analysis of the CYME Power graphical user interface that is
Customizable interface and Short-circuit
reports
Engineering Software is fully customizable to provide the Fault locator
designed for planning one-line diagram representation, Load flow Series and simultaneous
results and reports in a level of
studies and for the analysis detail needed by each user. In
Motor starting fault
of the entire distribution addition, innovative engineering Load allocation Voltage sag
technologies and industry
network. standards are at the core of
Load balancing
the CYME algorithms. With its Optimal capacitor placement
The modeling capabilities of extensive built-in equipment

and sizing
CYME includes the detailed libraries and advanced analyses,
representation of medium the CYME software can help
you create the most accurate
and low-voltage distribution network representation to yield
networks, and secondary the accurate results that are
grids. From planning to needed.
contingency scenarios to
optimization, the CYME
software is the perfect tool
to address any distribution
system analysis need.
Distribution Power Flow Analysis
Main analysis tool for the
Optimal Recloser Placement
To achieve a better level of
Advanced Project Manager
To manage time-based projects
design, planning and operation reliability by placing reclosers at and assess multiple scenarios in
System Analysis of any electrical power system. optimal locations. a flexible framework.

Fault Analyses Network Configuration Automated Network Forecast


Optimization Analysis
Tools to assess the effects of
different types of short-circuits, To reconfigure radial networks To manage and analyze time-
Reliable analytic and evaluates fault contributions to an optimal topology through referenced projects in batch
planning tools to improve from machines and helps the switching configurations. mode.
electrical network verification of equipment rating.
Single Contingency Arc Flash Hazards Analysis
performance. Enhanced Substation/Sub- Assessment and Restoration
To assess the safety risk of the
Network
To study what-if situations of a network to help ensure a safer
To model and analyze all single outage on a radial system work environment.
the major components of to establish an optimal switching
distribution substations and plan. Harmonic Analysis
sub-networks such as industrial
To evaluate the impact of
facilities, switchgear and vaults. Reliability Assessment
non-linear loads on the network
To assess the historic and to help engineers find mitigation
Secondary Grid Network
predictive performance of methods to harmonics issues in
Analysis
network assets and evaluate the system.
Detailed modeling and analysis improvements due to different
of heavily meshed secondary initiatives and configurations. Geographic Overlay
grids, which include complete
To display raster or vector map
vaults with their transformers, Protective Device Analysis
images (geographical land-base)
protective devices such as
Wide range of tools and as layers directly underneath
network protectors, secondary
analyses to assist in the design the electrical model for a better
lines and cables.
and validation scheme of power visualization of the electrical
networks. network.
Low Voltage Distribution
Network
Long-Term Dynamics Online Maps Service
Detailed modeling of low-voltage
Time-series simulation to To display map images from
distribution network with single-
study the impact of insolation online map providers as
phase center tap transformers
variations, wind fluctuations background of the distribution
and service drop cables. It also
and load variations on network network and locate specific
allows comprehensive analysis
controls. equipment and devices using
to calculate technical losses and
street addresses and GPS
identify overloaded equipment. Steady-State Analysis with coordinates.
Load Profiles
Volt/VAR Optimization
To perform time series load
To achieve peak shaving, reduce
flow analysis based on a
system losses and improve
combination of historical
voltage profile to optimize
consumption patterns and
network efficiency.
real-time monitoring based on
a combination of AMR data and
Optimal Voltage Regulator
historical consumption patterns.
Placement
Network optimization through Load Flow Contingency (N-p)
voltage regulation by finding the
Allows the study of what-if
optimal location and tap settings
scenarios and N-p contingencies
for voltage regulators.
to establish optimal network
operation.

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
2015 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 045 EN All other trademarks are property
March 2015 of their respective owners.
CYME
Power Engineering Software and Solutions

Long-Term Dynamics Analysis

Study the impact of irradiance variations, wind


fluctuations and load variations on network controls.

The growing demand for The CYME Long-Term Dynamics The module also allows the
Analysis module offers a study of reserve capability of
renewable sources of clean time-series simulation tool to any battery energy storage
energy has significantly study the impact of irradiance device.
increased the presence variations, wind fluctuations
and load variations on network Sun Radiation, Wind Speed
of wind and solar power controls such as regulators, and Load Profile
supplies for power load tap changers and switched
A curve library is included in
capacitors, and on the behavior
generation portfolios. of battery energy storage
the CYME software to allow
Utilities are now facing the user to create their own
devices.
long-term dynamics curve
the challenge of managing models along with generation
Long-Term Dynamics
variable sources of energy Analysis for Distributed Energy
curve models and motor
interconnections to the grid. curve models. The Long-term
Resources
Dynamics Analysis module uses
To prepare for increased The intermittency of wind and the following curves:
penetration levels and to cloud-over periods alters the Insolation
output of wind energy systems
plan the deployment of and photovoltaic (PV) generation. Wind speed
Distributed Generation By analyzing the impact of such
variations on regulators, load
Load
Resources (DER), new
tap changers and capacitor Generation
simulation tools are needed. switching, the Long-Term
Dynamics Analysis allows power
Motor
engineers to properly assess
the impact of DER integration
and to better understand related
technical issues such as var
control and voltage regulation.
Long-Term Accurate Equipment Modeling
Detailed distributed generator
The presence of battery energy
storage systems has increased
to support the importance of
Time-based simulation results
are illustrated in comprehensive
graphs. Reports are available
models, such as wind energy
Dynamics conversion systems (WECS), are
available. The CYME software
DER integration and to allow
peak-shaving.
for device controls such as
regulator tap changers, and for
the penetration level of each
features a detailed PV system The energy storage model takes
Analysis model for which the output
function is represented by
into account of charge and
discharge delays, and features
type of distributed generation
in the network. Detailed reports
and charts are also available
manufacturer data such as: the following controls:
for monitored devices. Power
Insolation curve model No monitoring: time driven engineers can easily evaluate
Study the impact of and load shape modes the performance of the system
irradiance variations, wind Current at maximum point with or without DER, determine
Power monitoring: power
fluctuations and load Voltage at maximum point
driven, power peak shaving,
the impact of different DER
locations and evaluate the effect
variations on network Evaluating System Impact
power following, power of different variable profiles.
controls. levelling modes
With the Long-Term Dynamics The Long Term Dynamics
DER monitoring: DER driven, Analysis module is a powerful
Analysis module, time-series
DER levelling, DER support tool to evaluate solar array and
simulations can be performed
and DER smoothing modes wind farm impacts on the power
to assess how the DER output
profile affects: system, preparing the network
for tomorrows higher DER
Voltage regulators penetration levels.
Load tap changers
Capacitors
The user can specify the
activation time delay, tap
changer delay and mechanism
delay data of the regulators and
LTCs tap changing algorithm in
order to prevent unnecessary
switching due to voltage
fluctuations. Time delays are also
available for shunt capacitors
and switchable shunt banks
to specify closing and tripping
delays. The user also has the
option to start the analysis at
any moment in time (other
than zero) in order to include
time-controlled capacitors in the
analysis.
Voltage regulators have four
reset modes: fast, induction
disc, delay and delay freeze
reset.

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
2015 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 019 EN All other trademarks are property
July 2015 of their respective owners.
CYME
Power Engineering Software and Solutions

Integration Capacity Analysis

Determine the hosting capacity of your distribution


system considering power quality and reliability.

The global trend for cleaner As the landscape of the This productivity tool saves labor The accurate results provided
distribution system evolves with time by allowing engineers to by the CYME Integration
power, supported by the the rapid emergence of new run simulations without the use Capacity Analysis are a key
arrival of new technologies renewable energy technologies, of manual tools. A minimum to support utilities in their
such as solar and wind electric distribution utilities number of parameters, such current and future generation
are challenged to accelerate as the maximum capacity to interconnection request
farms as well as affordable DER deployment and process consider and the peak and processing. Moreover, the
rooftop photovoltaic panels, interconnection requests in a minimum load conditions, are powerful reporting capabilities
timely manner. required before the assessment of the CYME software make it
has changed the distribution can be performed on a the perfect tool for publishing
system landscape. The The CYME Integration Capacity
complete or partial model of color-coded hosting capacity
Analysis module comes in handy
ever-increasing volume of to efficiently and consistently
the distribution system. The circuit maps for customers
maximum hosting capacity is and developers interested
distributed energy resources calculate the maximum
determined based on a set in suitable locations for DER
(DER) interconnection generation or load capacity that
of user-defined thresholds interconnection projects.
can be installed independently
requests creates a need referring to a list of criteria that
at each point of a distribution
includes thermal overloads,
for new innovative system without adversely
reverse power flow, abnormal
impacting its reliability and
engineering tools. The power quality.
steady-state voltages, transient
CYME Integration Capacity voltage variations (flicker),
reduction of protection reach
Analysis module allows and sympathetic tripping.
performing an assessment
of the generation or load
hosting capacity of a
distribution system without
compromising its reliability
and power quality.
Integration The CYME Integration Capacity
Analysis module calculates the
maximum generation or load
Illustrative results
Integration capacity analysis
results are displayed in a tabular
Capacity capacity at each point of the
distribution circuits analyzed.
report detailing the maximum
hosting capacity at each node
of the circuits analyzed. Results
Analysis Features
The analysis uses an iterative
for each individual constraint are
also provided.
method which considers:
Results can of course be used
Integration of generation or to color-code the one-line
load up to a user-defined diagram or feed the color map
Create comprehensive maximum capacity value function in order to graphically
color-coded hosting capacity emphasize locations with greater
Maximum fault contribution
circuit maps using the CYME for generation integration,
or lesser integration capacity.
Integration Capacity Analysis or customer type for load
module. integration
Load scaling factors or load
models for peak and minimum
load conditions
Customizable load flow
and short-circuit calculation
parameters
System reliability and power
quality are ensured by a series
of criteria-based verifications
including:
Thermal loading of monitored
devices based on user-defined
limits set by device type
Reverse flow through ICA results in the CYME software
monitored devices based on
a maximum permissible user-
defined value
Abnormal steady-state
voltages based on user-
defined over- and under-
voltage limits applicable
globally or by voltage range
(LV, MV, HV)
Voltage variations caused by
sudden generation or load
fluctuations based on a user-
defined limit
Reduction of protection
reach of monitored devices
considering pickup security
factor
Sympathetic tripping of
monitored devices considering
security factor

ICA Results on Map (MapQuest)

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
2016 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 066 EN All other trademarks are property
November 2016 of their respective owners.
CYME
Power Engineering Software and Solutions

DER Impact Evaluation

Tackle generation interconnection


studies in a few mouse clicks.
The acceleration of Whenever a DER application The module brings an immediate A comprehensive set of
fails the streamlined productivity gain by reducing color-coded summary and
distributed energy resources interconnection process, an to a minimum the amount of detailed reports permits a quick
(DER) deployment imposes engineer is required to carry manual work required at each identification of the issues
new challenges to electric further technical analysis to step of the analysis. Relying on and an easy appreciation of
determine if any adverse effects a simplified or detailed model their severity. Taking care of all
distribution utilities. exist and, in such case, decide of the installation, the module the hassles, the CYME DER
Handling the volume of on the appropriate mitigations. allows the creation of various Impact Evaluation module lets
This task can take several hours, study cases by combining engineers focus on what really
interconnection applications if not days, to accomplish since system loading conditions matters.
and assessing the effects plenty of verifications on an (e.g. peak and minimum load)
of each new installation array of load and generation with minimum and maximum
scenarios are involved. DER contributions (e.g. 0 and
on the distribution system 100%), all defined as simulation
require dedicated resources With the objective of speeding
parameters. Controlled load
up the interconnection process,
and tools. The CYME DER flow analyses are then executed
the CYME DER Impact
on each scenario to assess the
Impact Evaluation module Evaluation module automatically
impacts on the system in terms
performs a comprehensive
enable engineers to perform system impact study that
of steady-state voltage, transient
generation interconnection voltage variations (flicker),
integrates several criteria-based
thermal overloads and reverse
system impact studies within verifications and multiple
power flow.
scenarios in order to flag
minutes rather than hours abnormal conditions.
through the automation of
a series of repetitive, time-
consuming and error-prone
verifications.
DER Impact Scenarios
Scenarios are created as
Verifications
Verifications stemming from a
Results
Analysis results are returned in
the combination of diverse set of criteria with adjustable the form of a series of reports
Evaluation system loading conditions with
minimum and maximum DER
thresholds are performed on
each scenario.
clearly highlighting violations
using a simple and intuitive color
contributions. coding.
Steady-state voltage based
Definition of loading conditions on user-defined over- and A summary report provides an
using load scaling factors and/ under-voltage limits applicable overview of the most severe
Establish your analysis or load models globally or by voltage range interconnection impacts for
methodology using the (LV, MV, HV) each scenario
Inclusion of one or many DER
different simulation installations in the analysis Voltage variations caused by A steady state report details
parameters and let the scope sudden generation fluctuations the system minimum and
software handle the rest. (max to min, min to max) maximum steady-state
Automatic detection or manual
based on user-defined limits voltages, including voltage
selection of point of common
set by voltage level and at the regulators tap position and
coupling (PCC)
PCC switchable capacitor bank
Adjustment of DER minimum status
Thermal loading of monitored
and maximum contribution
devices based on user-defined A voltage variation report
as a percentage of generator
limits set by device type presents results for both a
rated power, inverter rating or
rapid increase and decrease in
active generation Reverse power flow through
generation
monitored devices (e.g.
voltage regulator, on-load tap
changers, etc.)
Generation ramping from
minimum to maximum
contribution by user-defined
increment
Power factor ramping from
minimum to maximum value
by user-defined increment

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
2016 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 064 EN All other trademarks are property
November 2016 of their respective owners.

Вам также может понравиться