Вы находитесь на странице: 1из 1

Nalgonda ANNEXURE-I

Check for Adequacy of Storm water drain- Lined drain

Average Runoff co-officient

Assuming water is coming into drain from main carriage way, paved shoulder and adjoining area as given
below:

Length Runoff
Product
(m) Coefficient
Main Carriage Way 3.50 0.90 3.15
Paved Shoulder 1.50 0.90 1.35
Earthern shoulder 1.00 0.40 0.40
Crash Barrier/slope 0.00 0.40 0.00
Sum 6.00 4.90
Pav = 0.817

Total Width 6.00 m


Average runoff co-efficient P = 0.817

Discharge Carrying Capacity of Drain

Assumed Longitudinal Slope S = 0.003%


Manning's co-efficient n = 0.017
Assumed depth of flow D = 0.75 m

Width of the drain W = 1.050 m


Area A = 0.7875 sq m
Perimeter P = 3.6000 m
Hydraulic Radius R = 0.2188 m
Velocity V = 0.1170 m/s
Discharge Carrying Capacity Qd = 0.0921 cumec

Time of Concentration, Critical Rainfall Intensity and Estimated Runoff

Time taken by the flow for travelling over road is neglected due to lesser length in comparision to length of the
Time of concentration, Tc = Lc/V
Critical rainfall intensity, Ic = (F/T)*((T+1)/(Tc+1))

Rainfall intensity = 7.53


Estimated Runoff, Qr = 0.028 P A Ic

Length of the drain Lc = 1,000 m


Time of concentration Tc = 23.748 hrs
Critical rainfall intensity Ic = 0.609 mm/hr
surface area Aw = 6.000 m^2
Estimated runoff Qr = 0.0835 cumec

Check (whether Qr<=Qd) TRUE