Owners Manual
____________________
2012 Riverbed Technology, Incorporated. All rights reserved.
Riverbed and any Riverbed product or service name or logo used herein are trademarks of Riverbed
Technology. All other trademarks used herein belong to their respective owners. The trademarks and
logos displayed herein can not be used without the prior written consent of Riverbed Technology or
their respective owners.
ii
Contents
System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . 18
iii
About the Front Bezel and the System Cover . . . . . 26
Removing the Front Bezel . . . . . . . . . . . . . . . . . . . . 27
Installing the Front Bezel. . . . . . . . . . . . . . . . . . . . . 27
Removing the System Cover . . . . . . . . . . . . . . . . . . 28
Installing the System Cover . . . . . . . . . . . . . . . . . . . 29
3 Getting Help . . . . . . . . . . . . . . . . . . . . 49
Contacting Riverbed . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Internet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
iv
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Professional Services. . . . . . . . . . . . . . . . . . . . . . . . 50
Documentation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
v
vi
1
About Your System
"Series EX560 and EX760 Systems Overview" on page 2
"Front-Panel Features and Indicator Lights" on page 3
"Back-Panel Features and Indicator Lights" on page 5
"LAN and WAN Port Indicator Lights" on page 7
"System Diagnostic Indicator Lights" on page 9
"System Messages" on page 11
"Field Replaceable Units" on page 16
"Non Field Replaceable Units" on page 17
"Technical Specifications" on page 18
"Power Requirements and Consumption" on page 19
"Other Information You Might Need" on page 20
1
Series EX560 and EX760 Systems Overview
Series EX560 and EX760 systems are Steelhead EX appliances designed for
small office deployments. The following table summarizes the Series EX560
and EX760 hardware platforms.
Table 1-1. Series EX560 and EX760 Hardware Platforms
2
Front-Panel Features and Indicator Lights
Figure 1-1 shows the controls, connectors, and indicator lights located on the
system's front panel (shown with the optional front bezel removed). Table 1-2
provides descriptions of the front-panel features.
1 2 3 4 5 6 7
3
Table 1-2. Descriptions of Front-Panel Features and Indicator Lights (continued)
4
Back-Panel Features and Indicator Lights
Figure 1-2 shows the controls, connectors, and indicator lights located on the
system's back panel, and Table 1-3 provides descriptions of the back-panel
features.
1 2 3 4 5 6 7 8 9
5
Table 1-3. Descriptions of Back-Panel Features and Indicator Lights (continued)
6
LAN and WAN Port Indicator Lights
Two LAN-WAN interface pairs are provided by the included 1 GbE TX copper
network interface card (NIC). The status of each port is indicated by four
columns of three LEDs adjacent to the four ports. The LAN and WAN ports are
located at the system back panel, as shown in Figure 1-2, "Back-Panel Features
and Indicator Lights" on page 5.
Figure 1-3 shows the locations of the LAN and WAN ports and the port status
indicator lights. Table 1-4 lists the port name, interface name, and location of
status lights for each port. Table 1-5 describes the codes for the port indicator
lights.
Table 1-4. LAN and WAN Port Interface Names and Status Indicator Lights
Port Label Port Name Interface Name Location of Port Status Indicator Lights
W1 WAN 1 wan0_1 Column of three LEDs labeled P0
L1 LAN 1 lan0_1 Column of three LEDs labeled P1
W0 WAN 0 wan0_0 Column of three LEDs labeled P2
L0 LAN 0 lan0_0 Column of three LEDs labeled P3
Table 1-5. Codes for LAN and WAN Port Indicator Lights
7
In the Steelhead Management Console and in the Riverbed Command-Line
Interface (CLI), you reference the LAN and WAN ports by their interface
names. The interface names for the gigabit Ethernet ports are formed by
combining the port type (lan or wan), the number of the slot containing the NIC
(0), and the number of the port pair (0 or 1): lan0_0, wan0_0, lan0_1, and
wan0_1.
NOTE: In Series EX560 and EX760 systems, the LAN and WAN port pairs are
numbered in descending order (1, 0) from left to right.
8
System Diagnostic Indicator Lights
A row of four system diagnostic indicator lights on the system front panel
displays error codes during system startup.
Table 1-6 lists the causes and possible corrective actions associated with the
system diagnostic indicator light codes. A highlighted circle indicates the light
is on; a non-highlighted circle indicates the light is off.
Table 1-6. Codes for System Diagnostic Indicator Lights
9
Table 1-6. Codes for System Diagnostic Indicator Lights (continued)
10
System Messages
System messages appear at the system console to notify you of a possible
problem with the system. Table 1-7 provides probable causes and corrective
actions for system messages.
NOTE: If you receive a system message not listed in the table, check the
documentation for the application that is running when the message appears or the
operating system's documentation for an explanation of the message and
recommended action.
System Message
Cause Corrective Actions
BIOS MANUFACTURING MODE detected.
MANUFACTURING MODE will be cleared before the next boot.
System reboot required for normal operation.
Serious BIOS problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
Caution! NVRAM_CLR jumper is installed on system board.
Please run SETUP.
Hardware configuration problem. Contact Riverbed Support at
CMOS memory (NVRAM) has been cleared. https://support.riverbed.com.
Invalid configuration information - please run SETUP program.
Serious BIOS problem halted the system. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
Keyboard controller failure.
Most likely a hardware problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
Keyboard data line failure.
Keyboard stuck key failure.
Most likely a hardware problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
Manufacturing mode detected.
Serious BIOS problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
11
Table 1-7. System Message Causes and Corrective Actions (continued)
System Message
Cause Corrective Actions
Memory Initialization Warning: Memory size may be reduced.
Hardware or memory problem. See "Servicing the Memory
System is not likely to boot or function. Modules" on page 33, and follow
the troubleshooting steps.
If the problem persists, contact
Riverbed Support at
https://support.riverbed.com to
obtain a FRU.
No boot device available.
Most likely a hardware problem. Check the SSD data and power
System will not boot or function. cable connections:
1 Turn off the system, and
disconnect it from the power
source.
2 Open the system.
3 Make sure that one end of the
SATA data cable is properly
connected to the SSD and that
the other end of the cable is
properly connected to the
SATA_A port on the system
board.
4 Make sure that one end of the
SATA power cable is
properly connected to the
SSD and that the other end of
the cable is properly
connected to one of the two
internal USB ports near the
front of the system.
5 Close the system.
6 Reconnect the system to the
power source, and turn on the
system.
7 If the problem persists,
contact Riverbed Support at
https://support.riverbed.com.
12
Table 1-7. System Message Causes and Corrective Actions (continued)
System Message
Cause Corrective Actions
PCI BIOS failed to install.
Serious BIOS or hardware problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
PCIe Training Error:
Expected Link Width is x, Actual Link Width is y.
Serious BIOS or hardware problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
SATA Port A device not found.
Serious BIOS or hardware problem. Check the SSD data and power
System is not likely to boot or function. cable connections:
1 Turn off the system, and
disconnect it from the power
source.
2 Open the system.
3 Make sure that one end of the
SATA data cable is properly
connected to the SSD and that
the other end of the cable is
properly connected to the
SATA_A port on the system
board.
4 Make sure that one end of the
SATA power cable is
properly connected to the
SSD and that the other end of
the cable is properly
connected to one of the two
internal USB ports near the
front of the system.
5 Close the system.
6 Reconnect the system to the
power source, and turn on the
system.
7 If the problem persists,
contact Riverbed Support at
https://support.riverbed.com.
13
Table 1-7. System Message Causes and Corrective Actions (continued)
System Message
Cause Corrective Actions
SATA Port B device not found.
Serious BIOS or hardware problem. See "Servicing the Hard Disk
System is not likely to boot or function. Drive" on page 45, and follow
the troubleshooting steps.
If the problem persists, contact
Riverbed Support at
https://support.riverbed.com to
obtain a FRU.
SATA port A device auto-sensing error.
SATA port A device configuration error.
SATA port A device error.
Serious BIOS or hardware problem. Check the SSD data and power
System is not likely to boot or function. cable connections:
1 Turn off the system, and
disconnect it from the power
source.
2 Open the system.
3 Make sure that one end of the
SATA data cable is properly
connected to the SSD and that
the other end of the cable is
properly connected to the
SATA_A port on the system
board.
4 Make sure that one end of the
SATA power cable is
properly connected to the
SSD and that the other end of
the cable is properly
connected to one of the two
internal USB ports near the
front of the system.
5 Close the system.
6 Reconnect the system to the
power source, and turn on the
system.
7 If the problem persists,
contact Riverbed Support at
https://support.riverbed.com.
14
Table 1-7. System Message Causes and Corrective Actions (continued)
System Message
Cause Corrective Actions
SATA port B device auto-sensing error.
SATA port B device configuration error.
SATA port B device error.
Serious BIOS or hardware problem. See "Servicing the Hard Disk
System is not likely to boot or function. Drive" on page 45, and follow
the troubleshooting steps.
If the problem persists, contact
Riverbed Support at
https://support.riverbed.com to
obtain a FRU.
The amount of system memory has changed.
Hardware or memory problem. See "Servicing the Memory
System is not likely to boot or function. Modules" on page 33, and follow
the troubleshooting steps.
If the problem persists, contact
Riverbed Support at
https://support.riverbed.com to
obtain a FRU.
Time-of-day not set - please run SETUP program.
Coin cell battery needs to be replaced. Contact Riverbed Support at
Provides backup power for the real-time clock https://support.riverbed.com.
(RTC) and for CMOS memory (NVRAM).
Timer chip counter 2 failed.
Serious BIOS or hardware problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
TPM failure.
Serious BIOS or hardware problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
Warning! No micro code update loaded for processor n.
Serious BIOS or hardware problem. Contact Riverbed Support at
System is not likely to boot or function. https://support.riverbed.com.
15
Field Replaceable Units
Series EX560 and EX760 systems contain several field replaceable units
(FRUs) that you or a certified service technician can troubleshoot, remove from
the system, and replace without having to send the system to a repair facility.
IMPORTANT: Perform troubleshooting or repairs only as directed in the product
documentation or by the online or telephone service and support team. All other
servicing should be performed by a certified service technician only. Your warranty
does not cover damage due to servicing that is not authorized by Riverbed. Read
and follow the safety instructions in the Safety and Compliance Guide.
Table 1-8 describes the field replaceable units available for Series EX560 and
EX760 systems.
Table 1-8. Field Replaceable Units for Series EX560 and EX760 Systems
If any individual system fan is faulty, Riverbed recommends that you replace all three fans.
16
Non Field Replaceable Units
Many components inside Series EX560 and EX760 systems are not field
serviceable or replaceable.
IMPORTANT: Perform troubleshooting or repairs only as directed in the product
documentation or by the online or telephone service and support team. All other
servicing should be performed by a certified service technician only. Your warranty
does not cover damage due to servicing that is not authorized by Riverbed. Read
and follow the safety instructions in the Safety and Compliance Guide.
This document mentions several non field replaceable components for reference
purposes only, such as the following:
Solid-state drive (SSD) System board
Control panel board assembly 1U single-slot riser card
Power supply unit (PSU) 64-bit processor
PSU fan Heat sink
Cooling shroud System coin cell battery
If the system front panel displays a diagnostic indicator code that refers to a
system component that is not field serviceable or replaceable, the corrective
action described in Table 1-6, "Codes for System Diagnostic Indicator Lights"
on page 9, instructs you to contact Riverbed Support.
Similarly, if you encounter a system message that refers to a system component
that is not field serviceable or replaceable, the corrective action described in
Table 1-7, "System Message Causes and Corrective Actions" on page 11,
instructs you to contact Riverbed Support.
17
Technical Specifications
The following tables summarize the environmental and physical specifications
for Series EX560 and EX760 systems.
Table 1-9. Environmental Specifications of Series EX560 and EX760 Systems
18
Power Requirements and Consumption
Series EX560 and EX760 systems are rated at the following power
characteristics when operating at nominal AC input voltages (120 V and 230 V):
Table 1-11. Power Characteristics of Series EX560 and EX760 Systems
19
Other Information You Might Need
In addition to this hardware owners manual, the following Riverbed Steelhead
appliance documentation contains information related to EX560 and EX760
system hardware:
Safety and Compliance Guide
Network Interface Card Installation Guide
Rack Installation Guide
Steelhead EX Installation and Configuration Guide
You should also read the following information:
Product update informationAlways check for product update information
on the Riverbed Support web site at https://support.riverbed.com. Read the
updates first, because they often supersede information in other documents.
Safety and regulatory informationRead and understand any safety and
regulatory information that shipped with your system. Warranty information
may be included within this document or as a separate document.
20
2
Servicing Field Replaceable Units
"Overview of Servicing FRUs" on page 22
"Opening and Closing the System" on page 26
"Removing and Installing the Cooling Shroud" on page 30
"Servicing the Memory Modules" on page 33
"Servicing the System Fans" on page 38
"Servicing the Network Interface Card" on page 42
"Servicing the Hard Disk Drive" on page 45
21
Overview of Servicing FRUs
This section covers the following information:
Field Serviceable Parts
Safety and Compliance Guidelines
Recommended Equipment for Servicing FRUs
Inside the System
System Board Connectors
attaching a keyboard, mouse, and VGA display to the back-panel USB and video ports.
22
Inside the System
Figure 2-1 shows the system with the front bezel and system cover removed to
provide an interior view of the system as seen from above the right front corner.
4 5
3
6
2
7
1
14
13 9
12 10
11
Non-serviceable components shown for reference only.
23
System Board Connectors
The system board occupies about two-thirds of the chassis footprint, aligned
against the system back panel and the right-hand side of the chassis. Figure 2-2
is a diagram of the system board with connector locations shown. The edge of
the board shown at the top of the diagram is located against the system back
panel. Table 2-1 describes the system board connectors.
1 2 3
10
9 8 7 6 5 4
24
.
Table 2-1. System Board Connectors
25
Opening and Closing the System
This section covers the following information:
About the Front Bezel and the System Cover
Removing the Front Bezel
Installing the Front Bezel
Removing the System Cover
Installing the System Cover
26
Removing the Front Bezel
Pull the bezel away from the system.
27
Removing the System Cover
1 Turn off the system, and then disconnect the system from the power source.
NOTE: Before you remove the system cover, always turn off the system and
and disconnect the system from the power source. Leaving power on can
cause permanent electrical damage to electrical components in your system.
2 Rotate the latch release lock counter clockwise to the unlocked position. See
Figure 2-4.
3 Grasp the cover on both sides while pressing your thumbs on the latch release
lock and the indent, carefully slide the cover toward the back of the system,
and lift it away from the system.
28
Installing the System Cover
1 Align the cover with the left and right edges of the system and offset it
slightly towards the back of the system, so that the pins on the inner edge of
the cover are aligned with the chassis hooks.
2 Slide the cover toward the front of the chassis till it locks in position.
3 Rotate the latch release lock in a clockwise direction to secure the cover.
29
Removing and Installing the Cooling Shroud
This section covers the following information:
About the Cooling Shroud
Removing the Cooling Shroud
Installing the Cooling Shroud
1 2
30
Keep the following points in mind when you remove the cooling shroud:
The memory modules and heat sink can get very hot during normal
operation. Ensure that the memory modules and heat sink have had sufficient
time to cool before you touch them.
Never operate your system with the cooling shroud removed. The system
may get overheated quickly, resulting in shutdown of the system and loss of
data.
31
Installing the Cooling Shroud
IMPORTANT: Troubleshoot or replace FRUs only. Troubleshoot or replace
FRUs only as directed in the product documentation or as directed by the Riverbed
online or telephone service and support team. All other servicing should be
performed by a Riverbed certified service technician. Your warranty does not cover
damage due to servicing that is not authorized by Riverbed.
1 Position the cooling shroud by aligning the guide slots with the guide screws
on the system board. See Figure 2-5, "Removing and Installing the Cooling
Shroud" on page 30.
2 Push the cooling shroud down until all edges are secured to the system board.
32
Servicing the Memory Modules
This section covers the following information:
About the Memory Sockets and Memory Modules
Supported Memory Module Configurations
Troubleshooting System Memory
Replacing a Memory Module
33
Supported Memory Module Configurations
Table 2-2 shows the supported configurations of 4 GB memory modules in
Series EX560 and EX760 systems. Socket numbers are labeled on the left side
of each socket. The socket labeled 2 is nearest to the 24-pin power connector.
Table 2-2. 4 GB Memory Module Configurations by Model
Memory module sockets labeled 2 and 1 are the first sockets of
channels B and A, respectively. The first socket of each channel
is identified by white release levers.
34
2 Turn on the system and then note the messages on the screen.
If an error message indicates a fault with a specific memory module, go to
step 12.
3 Turn off the system and then disconnect the system from the power source.
4 Open the system. See "Removing the Front Bezel" on page 27 and
"Removing the System Cover" on page 28.
5 Wear a grounding wrist strap.
6 Remove the cooling shroud. See "Removing the Cooling Shroud" on page 31.
7 Locate the four memory modules. See Figure 2-1, "Inside the System" on
page 23 and Figure 2-2, "System Board Connectors" on page 24.
CAUTION: The memory modules and heat sink can get very hot during
normal operation. Ensure that the memory modules and heat sink have had
sufficient time to cool before you touch them.
8 Check that the memory module sockets are populated correctly. See
"Supported Memory Module Configurations" on page 34.
9 Reseat the memory modules in their sockets. For details, see step 7 on
page 36.
10 Install the cooling shroud. See "Installing the Cooling Shroud" on page 32.
11 Close the system. See "Installing the System Cover" on page 29 and
"Installing the Front Bezel" on page 27.
12 Reconnect the system to the power source, and turn on the system.
13 As the system boots, observe any error message that appears and the
diagnostic indicators on the front of the system.
14 If the memory problem persists, you need to replace the faulty memory
module. Contact Riverbed Support at https://support.riverbed.com.
35
2 Open the system. See "Removing the Front Bezel" on page 27 and "Removing
the System Cover" on page 28.
3 Wear a grounding wrist strap.
4 Remove the cooling shroud. See "Removing the Cooling Shroud" on page 31.
5 Locate the four memory module sockets. See Figure 2-1, "Inside the System" on
page 23, and Figure 2-2, "System Board Connectors" on page 24.
CAUTION: The memory modules and heat sink can get very hot during
normal operation. Ensure that the memory modules and heat sink have had
sufficient time to cool before you touch them.
6 Press down and out on the ejectors at each end of the socket until the old memory
module pops out of the socket. See Figure 2-6.
IMPORTANT: Handle each memory module only on either card edge, and
avoid touching the middle of the memory module.
7 Press down and out on the ejectors at each end of the socket, as shown in
Figure 2-6, to allow the new memory module to be inserted into the socket.
36
8 Align the memory module's edge connector with the alignment key of the
memory module socket, and insert the memory module in the socket. The
memory module socket has an alignment key that allows you to install the
memory module in the socket in only one way.
IMPORTANT: Handle each memory module only on either card edge, and
avoid touching the middle of the memory module.
9 Press down on the memory module with your thumbs to lock the memory
module into the socket. When the memory module is properly seated in the
socket, the ejectors on the memory module socket align with the ejectors on
the other sockets that have memory modules installed.
10 Repeat step 7 through step 9 of this procedure to install the remaining
memory modules. See "Supported Memory Module Configurations" on
page 34.
11 Install the cooling shroud. See "Installing the Cooling Shroud" on page 32.
12 Close the system cover. See "Installing the System Cover" on page 29 and
"Installing the Front Bezel" on page 27.
13 Reconnect the system to the power source, and turn on the system.
37
Servicing the System Fans
This section covers the following information:
About the System Fans
Troubleshooting the System Fans
Replacing a System Fan
38
2 Locate the faulty fan indicated by the output of the RiOS CLI command
show stats fan. The command output displays the current RPM and error
status of the fan that you specify.
3 Turn off the system, and then disconnect the system from the power source.
4 Open the system. See "Removing the Front Bezel" on page 27 and
"Removing the System Cover" on page 28.
5 Remove the cooling shroud. See "Removing the Cooling Shroud" on
page 31.
CAUTION: The memory modules and heat sink can get very hot during
normal operation. Ensure that the memory modules and heat sink have had
sufficient time to cool before you touch them.
6 Reseat the power cable of each system fan. For the locations of the three
system fans, see "System Board Connectors" on page 24.
7 Close the system. See "Installing the System Cover" on page 29 and
"Installing the Front Bezel" on page 27.
8 Reconnect the system to the power source, and then turn on the system.
9 If a fan does not function, turn off the system and install a new fan.
See "Replacing a System Fan" on page 39. If the replacement fan does not
operate, contact Riverbed Support at https://support.riverbed.com.
39
CAUTION: The memory modules and heat sink can get very hot during
normal operation. Ensure that the memory modules and heat sink have had
sufficient time to cool before you touch them.
NOTE: The fan can continue to spin for some time after the system has been
powered down. Allow time for the fan to stop spinning before removing it
from the system.
4 Disconnect the fans power cable from the system board. See Figure 2-7.
5 Grasp the old or failed fan and lift it away from the fan assembly. See
Figure 2-7.
6 Ensure that the new or replacement fan is oriented correctly. Orient the fan
module so that the side with the power cable faces the back of the system.
7 Lower the fan into the fan assembly until the fan is fully seated. See Figure 2-7.
8 Connect the fans power cable to the fan power connector on the system
board.
9 Repeat step 4 through step 8 to replace all three system fans.
40
10 Replace the cooling shroud. See "Installing the Cooling Shroud" on page 32.
11 Close the system. See "Installing the System Cover" on page 29 and "Installing
the Front Bezel" on page 27.
12 Reconnect the system to the power source, and then turn on the system.
41
Servicing the Network Interface Card
This section covers the following information:
Troubleshooting the Network Interface Card
Replacing the Network Interface Card
Series EX560 and EX760 systems support one 4-port GbE TX copper NIC
installed in an expansion-card riser. The NIC is not hot-swappable.
42
Replacing the Network Interface Card
IMPORTANT: Troubleshoot or replace FRUs only. Troubleshoot or replace
FRUs only as directed in the product documentation or as directed by the Riverbed
online or telephone service and support team. All other servicing should be
performed by a Riverbed certified service technician. Your warranty does not cover
damage due to servicing that is not authorized by Riverbed.
1 Unpack the NIC and prepare it for installation. For detailed instructions, see
the Network Interface Card Installation Guide.
2 Turn off the system, and then disconnect the system from the power source.
3 Open the system. See "Removing the Front Bezel" on page 27 and
"Removing the System Cover" on page 28.
4 Disconnect all cables from the network interface card.
5 Lift and rotate the expansion-card latch. See Figure 2-8.
1 2
43
6 Grasp the old or failed NIC by its edges and carefully remove it from the
connector on the expansion-card riser.
7 Holding the new or replacement NIC by its edges, position the card so that
the card-edge connector aligns with the expansion-card connector on the
expansion-card riser.
8 Insert the card-edge connector firmly into the expansion-card connector until
the card is fully seated.
9 Close the expansion-card latch. See Figure 2-8.
10 Close the system. See "Installing the System Cover" on page 29 and "Installing
the Front Bezel" on page 27.
11 Reconnect the system to the power source, and then turn on the system.
12 Re attach the Ethernet cables to the LAN and WAN ports.
44
Servicing the Hard Disk Drive
This section covers the following information:
About the Hard Disk Drive
Troubleshooting the Hard Disk Drive
Replacing the Hard Disk Drive
45
4 Make sure that the 5-wire SATA power cable from the PSU is properly
connected to the HDD.
5 Close the system. See "Installing the System Cover" on page 29 and "Installing
the Front Bezel" on page 27.
6 Reconnect the system to the power source, and then turn on the system.
7 If the problem persists, contact Riverbed Support at
https://support.riverbed.com.
46
Figure 2-9. Removing and Installing a 3.5-Inch Hard Drive
1 2
5 Install the new or replacement hard disk drive and attached drive carrier into
the chassis.
a Align the four slots under the drive carrier with the four tabs on the
chassis. See Figure 2-9.
b Slide the drive carrier toward the chassis wall till it snaps into place.
6 Connect the SATA power and data cables to the two receptacles at the back
of the hard drive. See Figure 2-9, "Removing and Installing a 3.5-Inch Hard
Drive" on page 47.
7 Close the system. See "Installing the System Cover" on page 29 and "Installing
the Front Bezel" on page 27.
8 Reconnect the system to the power source, and then turn on the system.
47
48
3
Getting Help
49
Contacting Riverbed
This section describes how to contact departments within Riverbed.
Internet
You can learn about Riverbed products at http://www.riverbed.com.
Technical Support
If you have problems installing, using, or replacing Riverbed products, contact
Riverbed Support or your channel partner who provides support. To contact
Riverbed Support, please open a trouble ticket at https://support.riverbed.com or
call 1-888-RVBD-TAC (1-888-782-3822) in the United States and Canada or +1
415 247 7381 outside the United States.
Professional Services
Riverbed has a staff of professionals who can help you with installation
assistance, provisioning, network redesign, project management, custom
designs, consolidation project design, and custom coded solutions. To contact
Riverbed Professional Services go to
http://www.riverbed.com/us/products/professional_services/ or email
proserve@riverbed.com.
Documentation
The Riverbed Technical Publications team continually strives to improve the
quality and usability of Riverbed documentation. Riverbed appreciates any
suggestions you might have about its online documentation or printed materials.
Send documentation comments to techpubs@riverbed.com.
NOTE: If you do not have an active Internet connection, you can find contact
information on your purchase invoice, packing slip, bill, or Riverbed Document
Kit.
50
Index
A removing, 28
Auxiliary port, 6
D
B DIMMs
See memory modules
back panel
features and indicator lights, 5
LAN and WAN ports, 7
E
bezel
about, 26 environmental specifications, 18
installing, 27
removing, 27
buttons F
back panel, 5 field replaceable units
front panel, 3 See also FRUs
front panel
features and indicator lights, 3
C FRUs
connectors See also non field replaceable units
back panel, 5, 7 about
front panel, 3 hard disk drive, 45
system board, 23-24 memory modules (DIMMs), 33
cooling shroud NIC, 42
about, 30 system fans, 38
installing, 32 list of field replaceable units, 16
removing, 31 replacing
hard disk drive, 46
cover, system
memory modules (DIMMs), 35
about, 26
NIC, 43
installing, 29
Index 51
system fans, 39 M
troubleshooting
management interface ports, 6
hard disk drive, 45
memory modules (DIMMs), 34 memory modules (DIMMs)
NIC, 42 about, 33
system fans, 38 replacing, 35
socket locations, 23-25
supported configurations, 34
troubleshooting, 34
H
hard disk drive
about, 45
N
replacing, 46
troubleshooting, 45 network interface card
See NIC
NIC
I See also LAN and WAN ports
about, 42
indicator lights
replacing, 43
back panel, 5
troubleshooting, 42
front panel, 3
LAN and WAN ports, 7 non field replaceable units, 17
system diagnostic, 9
interface names
LAN and WAN ports, 7-8 P
physical specifications, 18
port names
L LAN and WAN ports, 7-8
LAN and WAN ports power specifications, 19
about the NIC, 42
Primary port, 6
indicator lights, 7
interface names, 7-8
port names, 7-8
replacing a NIC, 43 R
troubleshooting a NIC, 42 replacing FRUs
hard disk drive, 46
52 Index
memory modules, 35
NIC, 43
system fans, 39
Riverbed
contacting
Professional Services, 50
Support, 50
Technical Publications, 50
web site address, 50
S
SATA hard drive
See hard disk drive
support
contacting Riverbed, 50
system board connectors, 23-24
system fans
about, 38
replacing, 39
troubleshooting, 38
T
trouble ticket web address, 50
troubleshooting
hard disk drive, 45
LAN and WAN ports, 42
memory modules, 34
NIC, 42
system fans, 38
Index 53
54 Index