2 REFERENCES ............................................................................................................................ 8
3.1 SYSTEMS - ALPHABETICAL DESIGNATION IN PARTICULAR PARTS ACC. TO DATA CHARACTER F1. .... 9
3.2 EQUIPMENT UNITS - ALPHABETICAL DESIGNATION OF DATA CHARACTER A1 .................................. 29
3.3 COMPONENTS - ALPHABETICAL DESIGNATION OF DATA CHARACTER B1.................................... 36
Process-related code
Process-related identification of systems and items of equipment according to their
functions in mechanical, civil, electrical and control and instrumentation ngineering.
The process-related designation is the most important designation. It is used in the
technical and civil engineering as well as in the electrical and control and
instrumentation engineering.
A = Alphabetical symbols (Latin alphabet except I and O and special symbols) N = Numeral
symbols (Arabic numerals) - see Doc. No. 0AM/13-1
The data characters in parentheses ( ) may be omitted if the code remains unique.
2 REFERENCES
VGB, "KKS Power Plant Classification System - Guidelines for Application and Key Part", B105e
VGB, "KKS Application Explanations", B106e, 5th Edition 10/2003
3 SYSTEMS, EQUIPMENT UNITS, COMPONENTS CLASSIFICATION
ACC. TO KKS
HA - Pressure system
HAA - LP part-flow feed heating system (flue-gas-heated)
HAB - HP part-flow feed heating system (flue-gas-heated)
HAC - Economiser system
HAD - Evaporator system
HAH - HP superheater system
HAJ - Reheat system
HAK - Secondary reheat system
HAN - Pressure system drainage and venting systems
HAX - Fluid supply system for control and protection equipment
HAY - Control and protection equipment
LB - Steam system
LBA - Main steam piping system
LBB - Hot reheat piping system
LBC - Cold reheat piping system
LBD - Extraction piping system
LBE - Back-pressure piping system
LBF - HP reducing station
LBG - Auxiliary steam piping system
LBH - Start-up steam system, shutdown steam system
LBJ - Moisture separator/ reheater (MSR)
LBK - Pressure relief system in main steam piping
LBQ - Extraction steam piping system for HP feedwater heating
LBR - Piping system for branch or auxiliary turbine
LBS - Extraction steam piping system for LP feedwater heating (main condensate)
LBT - Emergency condensing system
LBU - Common dump line
LBV - Lubricant supply system
LBW - Sealing steam system
LBX - Fluid supply system for control and protection equipment
LBY - Control and protection equipment
LC - Condensate system
LCA - Main condensate piping system (excl. main condensate pump system, LP
feedwater heating system and condensate polishing plant)
LCB - Main condensate pump system
LCC - LP feedwater heating system (main condensate)
LCE - Condensate desuperheating spray system
LCF - Branch turbine condensate piping system
LCG - Branch turbine condensate pump system
LCH - HP heater drains system
LCJ - LP heater drains system
LCL - Steam generator drains system
LCM - Clean drains system (collecting and return system)
LCN - Auxiliary steam condensate system (collecting and return system)
LCP - Stand-by condensate system incl.storage and pump system
LCQ - Steam generator blowdown system
LCR - Stand-by condensate distribution system
LCS - Reheater drains system ( moisture separator / reheater)
LCT - Moisture separator drains system (moisture separator/reheater)
LCW - Sealing and cooling drains system
LCX - Fluid supply system for control and protection equipment
LCY - Control and protection equipment
LD - Condensate polishing plant
LDA - Fluid treatment extraction system (if not part of another system)
LDB - Filtering, mechanical cleaning
LDC - Aeration, gas injection system
LDD - Electromagnetic polishing system
LDE - Acid proportioning system (e.g. for carbonate hardness removal)
LDF - Ion exchange, reverse osmosis system (e.g. demineralisation)
LDG - Evaporation system (e.g. for demineralisation)
LDH - Dearation, drying system
LDJ - Preheating, cooling system
LDK - Piping system, temporary storage system, pump system for main fluid
LDL - Storage system outside fluid treatment system (if not part of other system)
LDN - Chemicals supply system
LDP - Regeneration, flushing equipment
LDQ - Injection system for main fluid
LDR - Flushing water and residues removal system incl. neutralization
LDS - Sludge thickening system
LDT - Heating, cooling and flushing fluid distribution system
LDU - Lubricant supply system
LDX - Fluid supply system for control and protection equipment
LDY - Control and protection equipment
MK - Generator plant
MKA - Generator frame, incl. stator, rotor and all integral cooling equipment
MKB - Do not use ! (Use only if MKC is insufficient)
MKC - Exciter set, complete
MKD - Bearings
MKF - Stator/rotor liquid cooling system, incl. coolant supply system(except
cooling oil)
MKG- Stator/rotor gas cooling system, incl. coolant supply system
MKH - Stator/rotor nitrogen cooling system, incl. coolant supply system
MKQ- Exhaust gas system (if separate from MKG and MKH)
MKU - Stator/rotor cooling oil system, incl. coolant supply system
MKV - Lubricant supply system (if separate system for generator)
MKW- Sealing oil system, incl. supply and treatment
MKX - Fluid supply system for control and protection equipment
MKY - Control and protection equipment
MM- Compressor plant
MMA- Compressor, incl. internal systems
MMC- Air intake piping system
MMD- Bearings
MME- Intercooling system
MMF- Aftercooling system
MMG- Final cooling system
MMH- Discharge piping system
MMV- Lubricant supply system
MMW-Sealing fluid supply system
MMX- Fluid supply system for control and protection equipment
MMY- Control and protection equipment
PM - Closed cooling water system for transformers (if separate closed cooling water
system)
QJ - Central gas supply, also inert gas. Except for welding purposes. For central gas
supply system for main and heavy machinery see MK, ML, XK, XL
QJA - Gas supply and distribution
QJB - QJR - vacant
QJV - Lubricant supply system
QJW - Sealing fluid supply system
QJX - Fluid supply system for control and protection equipment
QJY - Control and protection equipment
SN - Elevators
SNA - vacant
SNB - vacant
SNC - In switchgear building
SND - In emergency feed building
SNE - SNF - vacant
SNG - In demineralisation building
SNH - In boiler house
SNJ - SNL - vacant
SNM - In steam turbine building
SNN - In other water treatment plant
SNP - In cooling water plants
SNQ - In plants of make-up cooling water preparation
SNR - In garages
SNS - In auxiliary plants
SNT - In auxiliary boiler house
SNU - In office and administration building
SNY - Control and protection equipment
3.1.9 U - Structures
UA - Structures for grid and distribution systems
UAA - Switchyard structure
UAB - Grid systems switchgear building
UAC - Grid systems control building
UAD - vacant
UAE - Structure for pneumatic control system
UAF - vacant
UAG - Structure for transformers
UAH - Structure for supports and equipment
UAJ - UAR - vacant
UAS - Shaft structure (shaft)
UAT - UAW - vacant
UAX - Special structure (plant-specific)
UAY - Bridge structure
UAZ - Ducting structure
UP - Structures for circulating (cooling) water systems (e.g. circulating water intake)
UPA - Circulating (cooling) water intake culvert
UPB - Service water intake culvert
UPC - Circulating water intake structure
UPD - Service water intake structure
UPE - UPG - vacant
UPH - Circulating water treatment structure
UPJ - Service water treatment structure
UPK - UPM - vacant
UPN - Circulating water inlet culvert
UPP - Service water inlet culvert
UPQ - Biocide treatment building
UPR - vacant
UPS - Flushing water culvert
UPT - Screen wash water cleaning structure
UPU - UPW - vacant
UPX - Special structure (plant-specific)
UPY - Bridge structure
UPZ - Ducting structure
UQ - Structures for circulating (cooling) water systems (e.g. circulating water pumps
and outfall)
UQA - Circulating (cooling) water pump building
UQB - Service (secondary cooling) water pump building
UQC - UQF - vacant
UQG- Circulating (cooling) water overflow structure, surge tank
UQH - Screen wash water discharge culvert
UQJ - Circulating (cooling) water seal pit, incl. circulating water aeration structure
UQK - Circulating water venting structure
UQL - Service (secondary cooling) water surge pond
UQM- Service (secondary cooling) water collecting pond
UQN - Circulating (cooling) water outfall culvert
UQP - Service (secondary cooling) water outfall culvert
UQQ- Circulating (cooling) water outfall structure
UQR - Service(secondary cooling) water outfall structure
UQS - Circulating (cooling) water discharge culvert
UQT - Service water discharge culvert
UQU - Circulating (cooling) water spillway structure
UQV - Structure for artificial circulating(cooling) water aeration
UQW- Routing structure for circulating (cooling) water discharge
UQX - Special structure (plant-specific)
UQY - Bridge structure
UQZ - Ducting structure
UR - Structures for circulating (cooling) water systems (e.g. recirculation cooling)
URA - Cooling tower structure (circulating/main cooling water)
URB - Cooling tower structure (service/secondary cooling water)
URC - vacant
URD - Cooling tower pump building (circulating/main cooling water)
URE - Cooling tower pump building (service/secondary cooling water)
URF - vacant
URG - Cooling tower connecting structure
URH - Cooling tower outlet structure
URJ - Cooling tower outfall culvert
URK - Cooling tower return structure
URL - Cooling tower return culvert
URM- Circulating (cooling) water distribution building
URN - Cooling tower bypass structure
URP - Cooling tower blowdown structure
URR - URW - vacant
URX - Special structure (plant-specific)
URY - Bridge structure
URZ - Ducting structure
UU - Shaft structures
XK - Generator
XKA - Generator frame, incl. stator, rotor and all integral cooling equipment
XKB - (use only if XKC is insufficient)
XKC - Exciter set
XKD - Bearings
XKF - Liquid cooling system (except cooling oil see XKU)
XKG - Gas cooling system (except nitrogen cooling see XKH) XKH - Nitrogen
cooling system include. supply system (other gas media see XKG)
XKQ - Exhaust gas system (if separate from XKG and XKH)
XKU - Cooling oil system (other fluid media see XKF)
XKV - Lubricant supply system (if separate for generator)
XKW- Sealing oil system (if separate for generator
XKX - Fluid supply system for control and protection equipment
XKY - Control and protection equipment
AG - Generator units
AM - Mixers, agitators
mixing units
neutralising equipment
BF - Foundations
BU -Insulation, sheating
acoustic enclosures (dedicated removable unit)
heat insulation
noise insulation
external sheeting
enclosures
sheating
EH - vacant
EJ - vacant
EK - vacant
EM - Process computer (also for operation and monitoring)
EN - vacant
EP - vacant
EQ - vacant
EU - Combined analog and binary signal conditioning
EW - Protection
EX - vacant
EY - vacant
EZ - vacant
3.2.6 F - Indirect measuring circuits
FD - density
FE - electrical variables (e.g. current, voltage, power, electr. frequency)
FF - flow rate
FG - distance, length, position, direction of rotation
FK - time
FL - level (also for dividing line)
FM - moisture, humidity
FP - pressure
FQ - quality, variables (analysis, material properties other than FD, FM, FV)
FR - radiation variables
FS - velocity, speed, frequency (mechanical), acceleration
FT - temperature
FU - combined and other variables
FV - viscosity
FW - weight, mass
FX - neutron flux for reactor power
FY - vibration, expansion
HD - Bearing assembly
K Mechanical components
M Mechanical components
Q Instrumentation and control components (non-electrical) - Electrical components
X Signal origin
Y Gated signals
Z Signal application
Note: Groups K and M of mechanical components can also be used for electric
and control equipment (e.g. KA for valves). In group Q components are
components of control equipment not included in group " - "
(e.g. impulse piping).
3.3.1 K - Mechanical components
KA - Gate valves, globe valves, dampers, cocks, rupture disks, orifices
KB - Gates, doors, dam boards
KC - Heaters, coolers
KD - Vessels, storage tanks, surge tanks
KE - Turning, driving, lifting, slewing gear
KF - Continuous conveyors, feeders
KJ - Size reduction machines
KK - Compacting, packaging machines
KM - Mixers, agitators
KN - compressors, blowers, fans
KP - Pumps
KT - Cleaning machines, driers, separators, filters
KV - Burners grates
KW - Stationary tooling and treatment machines for maintenance
4.2.2 It is recommended to use the oval of such a dimension to be possible to write legibly the
entire alphabetical and numerical codes defining I & C circuit. Minimal letter height
(recommended) is 2,5 mm.
4.1 The first letter indicates the measured or controlled variable. A suitable letter from the column
Letters, corresponding Measured (controlled) quantity of the table in the paragraph
1.4.4.2, is chosen. If needed, an additional letter from the column Additional character can
be added.
4.2 Further letters will be chosen from the column Function of circuit from above mentioned
table.
4.3 If in the lettered code besides the first letter character are also two or more other
characters, these characters shall be lined up in the order I R C T Q S Z A. (This condition
does not relate with additional letters, mentioned in the column Additional character. Letter
I may be omitted, if the indicator is provided with indication of measured variable.
4.2.3 It is recommended to use the united designation (for e.g. ovals) and dimensions of symbols
in whole documentation, while the basic position of symbols is always situated parallely with
the drawing border.
4.2.4 A stalk of symbol can also be broken, breaking must be (if possible) situated parallely with
the drawing border and it must end on the equipment outline in place for the signal
extraction.
4.2.5 For the local I & C circuit are drawn only so called empty symbols, i.e. without the halved line
drawn instead of the longer axis of symbol:
4.2.6 For the remote I & C circuit is symbol drawn with the halved line, which is drawn instead of the
longer axis of symbol. Symbol, which is drawn this way, specifies also the place of
information, in this case it is central (main) control room;
4.2.7 Symbol is drawn with two parallely halved lines, which are drawn instead of the longer axis of
symbol for the remote circuit, but with the matter that the place finformation shall be in the
auxiliary (secondary) control oom.
4.2.8 Symbol for local and remote I & C circuit can be also mutually connected so that they are
either drawn next to each other or above each other and the outline of symbols is
interconnected by comma. Signal line is usually represented by dashed line (DIN) or
uninterrupted line, which is crossed out in regular intervals by oblique line and oblique lines
form an angle with line approx. 60.
4.3 MEASURING CIRCUITS - KKS DESIGNATION ACC. TO PROCESS
4.3.1 Equipment classification
4.3.2 Alphabetical designation of measuring places (Breakdown level 2 - data characters A1A2)
Letter Z can only be used when emergency activity is required, for example shut down,
switched-off (not operational but the emergency shut down) etc.
For letters H directs, that H2 designates higher limit then H1. Letter H3 designates
higher limit then H2 etc. for letters L directs, that L2 designates lower limit then L1.
Letter L3 designates lower limit then L2 etc.
Letter L also designates position OFF and letter H designates position ON. (It directs for
manual, electrical and hydraulic drives or also for the mechanical parts).
In P&I diagrams the marks of position GI (0 - 100%), alike the marks of other
measuring circuits are drawn and that at valves, that are governed more-less or at
control valves and flaps, which are controlled from physical variables (level, pressure,
temperature, etc.) and it is for a reason that the position indicator is wired with cables
by the supplier I&C. In the electrical load list also the position indication 0 - 100% is
mentioned at these consumers.
4.3 Well-arranged alphabetical designation on data character A1A2
CD - density
CF - flow, rate
CK - time
CM - moisture, humidity
CP - pressure
CQ - quality variables (analysis, material properties other than CD, CM, CV)
CR - radiation variables
CT - temperature
CV - viscosity
Note: - We leave letter C if the Direct measuring circuit is used for the control.
DD - density
DE - electrical variables (e.g. Current, voltage, power, electr. Frequency)
DF - flow rate
DK - time
DM - moisture, humidity
DP - pressure
DQ - quality variables (analysis, material properties other than DD, DM, DV)
DR - radiation variables
DT - temperature
DV - viscosity
4.3 Second and third number N2, N3 is used for the serial numbering and it begins for
each group of measured quantities (temperature, pressure, flow etc.) always from
number 1 (01).
BREAKDOWN LEVEL 1
The subdivision of the elementary system (FN) is accomplished by taking numbers in the
direction of the flow. This subdivision may also be the limit of scope of supply between
partners. Gaps are left in the numbering.
BREAKDOWN LEVEL 2
- BR is the equipment code for all piping and ducts (codes A1 A2).
- The line order number (NNN) is taken in the direction of the flow. For this number,
the following series of numbers are defined:
0 system of pipeline
1 system of pipeline
2 system of pipeline
4 system of pipeline
5 system of pipeline
6 drain pipelines
7 vent pipelines
9 free useable
The 2nd number N2 is serial number of pipelines and is decimal. In case that number of
pipelines is great than 9 for individual system, is necessary divide mentioned system as
follows: last pipeline is LCW20 BR090, we continue LCW21 BR010)
A3 Designation
H Heat insulated
P Personnel protection
E Electrically traced
S Steam traced
W Water traced
A Acoustic protection
Electrical Tracing
10 LAB 20 BR 023 E
Order Number
Transformer
System Subdivision
principles:
Second number N2 is used for decade serial numbering and is coincident to the
serial number of piping branch (in which valve is installed), numbering of piping
branches is used on whole tenths.
Third number N3 is used for serial numbering of valves in the same piping branch by
use of numbers 0 to 9.
4.4 EXAMPLES
Alphabetical key acc. to ISO 3511-1 (see table page 6) or DIN 19 227 part 1.
Example 1
Pressure local measurement (empty symbol and first number "5" in three digit
number); i.e. measured quantity P (pressure) shall be indicated (I) close to the
instrumentation point.
Example 2
CA - Protective interlocks
CE - Annunciation
CEA - Cabinets for annunciation
system CEB - CEH - vacant
CEJ - Fault recording CEK -
CEQ - vacant
CF - Measurement, recording
CFA - Cabinets for measurement
CFB - CFF - vacant
CFL - Cabinets for radiation measurement
CFM - CFP - vacant
CFQ - Cabinets for recording (meters, pen recorders)
CH - Protection
CHA - Cabinets for generator and transformer protection
CHB - CHD - vacant
CHE - Cabinets for boiler protection
CHF - Cabinets for protections
CHG- CHY - vacant
CV - Marshalling racks
CY - Communication equipment
CYA - Telephone system (PABX)
CYB - Control console telephone system
CYC - Acoustic alarm system
CYD - Optical alarm system
CYE - Fire alarm system
CYF - Clock system
CYG - Remote control system
CYH - Telemetry system
CYJ - Remote metering system
CYK - HF carrier telephone system
CYL - Staff paging system, wireless
CYM- Staff paging system, inductive
CYN - Staff paging system, hardwired
CYP - Optical monitoring system
CYR - Pneumatic tube conveyor
CYS - Radiotelephone system (stations)
K Mechanical components
M Mechanical components
Q Instrumentation and control components (non electrical)
- Electrical components
X Signal origin
Y Gated signals
Z Signal application
K - Mechanical components
KA - Gate valves, globe valves, dampers, cocks, rupture disks,
orifices
KB - Gates, doors, dam boards
KC - Heaters, coolers
KD - Vessels/ tanks, pools, surge tanks (fluid systems)
KE - Turning, driving, lighting and slowing gear
KF - Continuous conveyors, feeders
KJ - Size reduction machines
KK - Compacting, packaging machines
KM - Mixers and agitators
KN - Compressors, blowers, fans
KP - Pumps
KT - Cleaning machines, dryers, separators, filters
KV - Burners, grates
KW - Stacionary tooling and treatment machines for maintenance
M - Mechanical components
MB - Brakes
MF - Foundations
MG - Gearboxes
MK - Clutches, couplings
MM - Engines (non electric)
MR - Piping components, ductwork components
MS - Positioners non electrical
MT - Turbines (no main or heavy machines)
MU - Transmission gear, non electrical, convertors and boosters
other
than couplings and gearboxes
X - Signal origin
(The specification of subgroups depends on I & C equipment execution
and must be discussed with participants at work)
Y - Gated signals
(The specification of subgroups depends on I & C equipment execution
and
must be discussed with participants at work)
Z - Signal application
(The specification of subgroups depends on I & C equipment execution
and
must be discussed with participants at work)
4.6.3 Examples of component designation
4.1 Temperature
Next valves (blow down valves) or cocks or three way test manometric valves,
three way valve sets, five way valve sets are designated as component of
measuring circuit KA.. (numbering from 01 to 99)
T-pieces or other valves at piping (fittings, cap nut, pipe union) is designated
MR.. (from 01 to 99)
LBA10 CP001 MR01
4.3 Quantity
Flow capacity sensor; behind circuit designation adds -B.. (from 01 to 99)
Instrument piping, which start behind extraction control valve is designated AA8..,
which finishes at the pressure transducer is designated QR.. (from 01 to 99)
Level measuring gauge with analog output (pressure difference indicator , level
indicator float, ultrasonic sensor, capacitive probe etc.) behind circuit designation
adds QP .. (from 01 to 99)
Next valves (blow down valves), three way valve sets are designated as
components of measuring circuit KA.. (from 01 to 99)
Instrument piping, which start behind the extraction control valve is designated
AA8.. which finishes at the pressure transducer is designated QR.. (from 01 to
99)
Note : The reducing valve (KA) for medium, cooler (KC) and katex filter (KT) are
also designated as components of measuring circuit.
4.6 Flue gas analysis
The extraction control valve (see valve designation) is designated AA 8.. (It
concerns primary extraction control valve)
HNA10 AA810
Instrument piping, which starts behind the extraction control valve is designated
AA8.. which finishes at the pressure transducer is designated QR.. (from 01 to
99)
T-pieces or other valves at piping (fittings, cap nut, pipe union) are designated
MR.. (from 01 to 99)
Note: The equipment for the transport of sample (diaphragm pump, sieve, etc.)
is designated as MR.. (from 01 to 99)
Off-take pipe with flange for zircon probes is designated QT.. (from
01 to 99)
4.8.1 Indicating instrument of el. quantities (current, voltage, el. frequency etc.) is
designated so that behind circuit designation is added -P.. (from 01 to 99)
4.8.2 Recording instrument (with el. bonding also multiple-curves) behind circuit
designation is added -P.. (from 01 to 99)
4.8.3 Controller (analog, ekvipercentage etc. with el. bonding) behind circuit
designation is added -N.. (from 01 to 99)
4.8.4 Signal lamps (or luminous transparent lights etc.) for the limits reporting of
process quantities
LAC10AA110 -S22
4.8.8 Buttons for "STOP" (into function of three-button and for immediate shut
down of equipment from place) behind el. equipment symbol is added -S33
4.8.9 Buttons for emergency shut-down as for "FIRE" or "DANGER" (also for
escape route) behind el. equipment symbol, which firstly receives the shut
down signal, is added -S55
1 CWA01 -S01
4.8.11 Buttons for "ANNUNCIATION TEST" (Signal lamps) behind group and
switchboard symbol is added -S02
1 CWA01 -S02
4.8.12 Buttons for " FUNCTION ACKNOWLEDGEMENT " (e.g. finished start-up of
function group and (or) event. the following releases of other activity after
acknowledgment).
4.8.14 Signal lamps for "ON" or "OPEN" behind equipment symbol is added -H11
4.8.15 Signal lamps for "LOCAL CONTROL" (i.e. remote control off) behind
equipment symbol is added -H23
Recommended designation:
Behind symbol and number of group function (or device as unit) is added -
H45
4.8.19 Signal lamps for "FIRE", "DANGER" or "EMERGENCY SHUT DOWN - "
Behind el. equipment symbol or shut-down equipment is added -H99
4.8.20 Signal lamps for "BLOCKING OPERATION" (as for the el. equipment also
for the functional groups) " behind el. equipment symbol or functional group
is added -H88
Note: Signal lamps and buttons for other, here not mentioned requirements can
be designated in respect to these directories after the discussion with
participated sites.
4.8.22 Switches are designated so that behind the el. equipment symbol, device
as unit (details must be classified by double digit number from 01 to 99
functional groups or acc. to logically followed function is added - S.. (from
01 to 99)
4.9 TERMINAL EQUIPMENT AND MECHANISM
4.9.1 Control valves, flap valves: Designation acc. to valve designation
4.9.2 Terminal amplifier (e.g. NOTREP) Behind control valve symbol (flap valve) is added - n.. (from
01 to 99)
4.10.2 Letters and main group B1 designation for operational parts from operational parts signals and
its use key:
K Mechanical components
M Mechanical components
Q Instrumentation and control components (non electrical)
- Electrical components
X Signal origin
Y Gated signals
Z Signal application
Division B2 for components can be selected from valid component key 0AM/13_2.
Division for "signals and signals use" can not be specified with the general validity
because it is depending on the elaboration of I&C system.
Therefore it is important to discuss the subgroups and details specification with participants of
the project engineering.
Each of signals listed in I/O list document will comply following rules.
The following symbols shall be used for signal function. The relevant signal types
are given within brackets.
0 Not used
2 Not used
3 Not used
4 Not used
5 Not used
6 Not used
7 Not used
8 Not used
9 Not used
The Fourth and Fifth digit de means NUMBER OF FUNCTION
01 Command OPEN
02 Command CLOSE
04 Command STOP
05 Control position
06 Command
07 Electrical protection
08 ALARM
09 Interlocking
10 OPEN
11 CLOSED
12 RUN
13 READY
14 Control LOCAL
15 Control REMOTE
16 Measuring
17 Position feedback
18 Status
19 Release condition
22 Speed 1
23 Speed 2
5 DESIGNATION OF ELECTRIC EQUIPMENT ACC. TO KKS
AP - Control consoles
APA - APZ - vacant AQ - Measuring and metering equipment
AR - Protection equipment
ARA - ARZ - vacant
AX - Central equipment
AXA - AXZ - vacant
AY - Communication equipment
AYA - Telephone system (PABX)
AYB - Control console telephone system
AYC - Alarm system (acoustic)
AYD - Alarm system (optical)
AYE - Fire alarm system
AYF - Clock system
AYG - Remote control system
AYH - Telemetry system
AYJ - Remote metering system
AYK - HF carrier telephone system
AYL - Staff paging system, wireless
AYM - Staff paging system, inductive
AYN - Staff paging system, hardwired
AYP - Optical monitoring system
AYQ - Superior gas alarm equipment
AYR - locked out of service
AYS - Radiotelephone system
AYT - AYZ - locked out of service
AZ - locked out of service
5.1.2 B - Power transmission and auxiliary power supply
BA - Power transmission
BAA -Generator leads (from generator bushing up to bushing of
block transformer and house transformer incl. instrument
transformer and cooling and ventilation equipment)
BAB - Foundation cabinets
BAC - Generator circuit breaker, also commutating pole circuit
breaker, incl. cooling system
BAT - Generator transformers, incl. cooling system
BAU - Grounding equipment and flash protection
BAX - Control air supply system
BAY - Control and protection equipment
BT - Battery system
BTA - BTK - Batteries
BTL - BTV - Battery chargers + Rectifiers
BTW- BTZ - Common equipment
0 6 and 12 V
1 ...................... 110 V
2 ....................... 24 V
4 ...................... 48 V
6 ...................... 60 V
8 ...................... 220 V
Second number N12 is used for the serial numbering (from 0 to 9). There
are first inexhaustible numbers of vacant voltage level used If there are
missing numbers in the respective decades.
GB - vacant
GC - vacant
GD - vacant
GE - vacant
GF - vacant
GG-vacant
GH - Electrical and instrumentation and control installation units identified
as per process system (e.g. cubicles, boxes)
GK - Information display and operator control equipment for process computers
and automation systems
GT - Transformer equipment
GZ - Hangers, supports and racks for electrical and instrumentation and control
equipment
5.4 EQUIPMENT UNIT NUMBERING - BREAKDOWN LEVEL 2 - DATA CHARACTER AN
A1A2 AN (A3)
AA N1N2N3 (A)
There are used numbers for the serial numbering of aggregates at the place of
aggregates for letter G - electric power plant equipment. Unimportant zeroes
must be mentioned.
A1A2 AN (A3)
AA N1N2N3 (A)
- electrical components
-A - Assemblies and sub-assemblies
-C - Capacitiors
-E - Special components
-F - Protective devices
-H - Signalling devices
-K -Relay, contactors
-L -Inductors
-M - Motors
-N - Amplifiers, controllers
-Q - Power switchgear
-R - Resistors
-S - Switches, selectors
-T - Transformers
-V - Tubes, semiconductors
M mechanical components
X signal origin
Y gated signals
Z signal application
It is used for the component counting - the introductive zero must be written. It
is recommended to use the same two numbers for components of the same
function at the frame of standard connection. The following numbering method
proved to be good for some electrical components.
5.7.1 The breakdown of electrical components for codes -H, -K, -S, -W, -X
5.2 -K Relay
-K21 (start/stop)
-K31 (start 1, on.)
-K32 (start 2 - reversation, off.)
-K41 (open, more)
-K42 (close, less)
-K51 (remotely)
-K6.; -K7.; -K8.; -K9.; (Free to use)
5.4 -W Cables
This designation is used for the point of installation identification in assembly units for
instrumentation and control system (for e.g. in cubicles, panels, consoles etc.). Not
only is this designation important for cabling but for the interconnection of electrical
equipment and equipment of the control technical as well.
This method of designation acc. to point of installation identification in assembly units
serves only for the instrumentation and control system.
There are the same principles in the breakdown level 0 and 1 as for the designation of
process mentioned in 1.3.1, 1.3.2, 1.3.3 a 1.3.4 therefore we do not mention it again.
5.8.2 Code of installation point - Breakdown level 2
The alphabetical designation of installation point in the vertical direction (rows
designation) is done by data characters A1A, data characters AN indicate counting in the
horizontal direction (columns numbering). Data character A3 can be used for designation of
special integrated equipment of design groups or design units, or further breakdown of AN
can be used.
As alphabetical letters (without I and O) are used, on data characters A1A2 for point of
installation identification in the assembly unit there occurs the combination of letters as for
the aggregate designation acc. to process. In order to discriminate it from other types of
designation there must be written (period) "." in front of the breakdown level 2.
As a result to a fact that there are often used codes next to each other in the electric
therefore there is used "=" (sign of equality) in front of designation code acc. to process
and "+" in front of designation code acc. to point of installation, which in similar cases
neither have to contain level 2 nor period for the discrimination of prefix code, which can
fall off in case that the specification stays unambiguous.
The following principles direct for the designation of installation point in assembly units:
The counting direction and counting sequence derive from the initial position data (KU) at
the view to the front side.
The counting direction at the view to the front side is from left to right and from top to
bottom.
The counting direction at the view to the back side is from right to left and from top to
bottom.
Vertical breakdown in axis Y (i.e. rows designation) is designated with Capital letters.
Horizontal breakdown in axis X (i.e. columns numbering) is designated with Arabic
numbers.
5.9 DESIGNATION EXAMPLES OF ELECTRICAL EQUIPMENT ACC. TO KKS
5.9.1 Designation of power generation units - data character G
5.1 There are for example more generators in one combined unit. Steam turbine MA. is connected
to generator MK., as well as the gas turbine MB. is connected to next generator MK.;
generators equipment of steam turbine is then 1MK., generators equipment of gas turbine is
then designated 2MK. (take notice of fact that space is not written behind this number as it is
done for the number designating power generation unit). Occasionally it is more suitable (with
respect to replacement possibility for designation of units) to discriminate such equipment on
data character FN (generators equipment of steam turbine is MK10, gas turbine is MK20 etc.).
5.2 Analogously use prefix codes for power outlet:
5.3 Use prefix codes of power outlet for connection without house transformer with average
voltage:
5.9.3 Designation of
transformers
5.1 Designation of
transformers is done inside of the main group B according to following principles:
1 BAT81
5.3 Designation of equipment at transformer
For unambiguous designation, for example for laying are transformer winding
designated on aggregate data character A1A2 by group of letters GT -
equipment of transformer and on data character AN are calculated from first
to last one by side of higher voltage:
This equipment (big and smaller) are independently on the installation point, classified
already in the breakdown level 1 in alphabetical part (data character F1F2F3).
Numbers on data characters FN serve for the fields numbering, voltage levels or other
agreed designations.
Switchgear 1 BFA
Switchgear 2 BFB
Switchgear 3 BFC
5.1 Third field designation of second main switchboard of power generation unit 1
1 BFB03
5.2 Designation of components in switchboard
1 BJA01 -Q01
2 BTA21
5.9.5 Designation of control and deblocking cabinets at engine and its components.
LAC10 GH110P
5.2 Contactor designation in the above mentioned control and deblocking cabinet shall be :
+ BBA
Pumping aggregates LAC10 AP110, MAG20 AP110 and PAC10 AP110 are
fed from switchgear BBA. In the field +BBA01 is for e.g. located the
distribution device (power generation switch etc.) for pumping aggregate
LAC10 AP110. This outlet is designated by process code symbol =LAC10
AP110. Analogously it is done with other outlets.