MIANO-18 WELLHEAD COMPRESSION PROJECT

LINE INDEX TABLE FOR


MIANO-18 WELLHEAD COMPRESSION

ISSUED FOR
CONSTRUCTION
29 SEP, 2016

D1 29-Sep-16 Issued for Construction AAz SHa HAk MAh

A1 9-Sep-16 Issued for Approval AAz SHa HAk MAh

LOCAL PROJ.
Rev Date Description ORIG CHKD LE PM
REPR. MAN

Revisions Approval Client Approval

TITLE :

LINE INDEX TABLE FOR


MIANO-18 WELLHEAD COMPRESSION

SMEC Oil & Gas (Pvt) Ltd. PH +92 51 2289201


3RD FLOOR, ICCI BUILDING FAX +92 51 2289205
SECTOR G-8/1 , ISLAMABAD Web. www.smec.com
DOCUMENT NO:
2034-11-13-10-IX-001-D1
PROJECT NO.
PROJECT AREA CODE SYSTEM DISC TYPE SEQ. NO. REV.
2034

1 of 2
OMV (PAKISTAN) GmbH DOC. # 2034-11-13-10-IX-001
MIANO-18 WELLHEAD COMPRESSION PROJECT
DATE: 29-Sep-16
REV: D1
LINE INDEX TABLE FOR MIANO-18 WELLHEAD COMPRESSION

Hydrotest Paint Sys.#


Insulation Oper. Cond. Design Cond. NDE PWHT Test Medium
Pressure (Note-1)
Line Size Piping Class Fluid Flow Fluid Density
Sr. No. Line # Fluid Area Number Sequential No Rating(#) P & ID NO. From To
(Inch) (Note 5) (lb/hr) (lb/ft3) 0 0
Type Press (psig) Temp F Press (psig) Temp F Press (psig) % Yes/No Hydro/Pneum -

6"-PT-13-131A-M4AQ 1500
1 6"-PT-13-401-M4AQ 6" PT 13 401 M4AQ 900 N/A 2022-11-13-10-PD-004-01 13-PV-1827 43080 4.7 194 1885 250 2828 100 No Hydro 1
(TP-1801) (Note 3)

800
2 6"-PT-13-402-M4AQ 6" PT 13 402 M4AQ 900 N/A 2022-11-13-10-PD-004-01 13-PV-1827 6"-PT-13-404-M4AQ-P 43080 4.7 194 1885 250 2828 100 No Hydro 1
(Note 4)

6"-PT-13-332-M0UQ-P 800
3 6"-PT-13-403-M0UQ-P 6" PT 13 403 M0UQ 900 P 2022-11-13-10-PD-004-01 6"-PT-13-404-M4AQ-P 43080 4.7 194 1885 250 2828 100 No Hydro 1
(TP-1802) (Note 4)

800
4 6"-PT-13-404-M4AQ-P 6" PT 13 404 M4AQ 900 P 2022-11-13-10-PD-004-01 6"-PT-13-402-M4AQ V-1 43080 4.7 194 1885 250 2828 100 No Hydro 1
(Note 4)

1500
5 1/2"-PT-13-421-M4AQ 1/2" PT 13 421 M4AQ 900 N/A 2022-11-13-10-PD-004-01 6"-PT-13-401-M4AQ Produced Water Sample Bottle NNF 4.7 194 1885 350 2828 100 No Hydro 1
(Note 3)

6 1/2"-WP-13-422-M4AQ 1/2" WP 13 422 M4AQ 900 N/A 2022-11-13-10-PD-004-01 Produced Water Sample Bottle Sample And Drain Point NNF 4.7 ATM AMB 215 230 323 100 No Hydro 1

7 1/2"-VH-13-423-M4AQ 1/2" VH 13 423 M4AQ 900 N/A 2022-11-13-10-PD-004-01 Produced Water Sample Bottle Vent To Safe Location NNF 0.1 ATM AMB 215 230 323 100 No Hydro 1

800
8 6"-PT-13-424-M4AQ 6" PT 13 424 M4AQ 900 N/A 2022-11-13-10-PD-004-01 6"-PT-13-404-M4AQ-P Spare Connection NNF 4.7 194 1885 350 2828 100 No Hydro 1
(Note 4)

9 1"-WP-13-405-A3AQ 1" WP 13 405 A3AQ 150 N/A 2034-11-13-10-PD-001-01 Miano-18 Wellhead Compressor Package 1"-WP-13-427-A3AQ NNF 59.5 ATM 212 215 350 323 100 No Hydro 1

6"-PT-13-131A-M4AQ
10 4"-PT-13-406-M4AQ-P 4" PT 13 406 M4AQ 900 P 2034-11-13-10-PD-001-01 Compressor Skid 21250 6.1 1500 194 1885 350 2828 100 No Hydro 1
(TP-1803)

Compressor Skid
11 1"-PT-13-407-M4AQ 1" PT 13 407 M4AQ 900 N/A 2034-11-13-10-PD-001-01 V-3 NNF 6.1 1500 212 1885 350 2828 100 No Hydro 1
(A-31403)

12 1"-PT-13-408-M4AQ 1" PT 13 408 M4AQ 900 N/A 2034-11-13-10-PD-001-01 Compressor Discharge V-3 Note-2 6.1 1500 212 1885 350 2828 100 No Hydro 1

13 1"-PT-13-409-M4AQ 1" PT 13 409 M4AQ 900 N/A 2034-11-13-10-PD-001-01 Compressor Discharge V-1 and V-2 Note-2 6.1 1500 212 1885 350 2828 100 No Hydro 1

14 2"-WP-13-410-M4AQ 2" WP 13 410 M4AQ 900 N/A 2034-11-13-10-PD-001-01 V-1, V-2 Compressor Discharge Note-2 59.5 1500 140 1885 250 2828 100 No Hydro 1

15 2"-WP-13-411-M4AQ 2" WP 13 411 M4AQ 900 N/A 2034-11-13-10-PD-001-01 V-3 Compressor Discharge Note-2 59.5 1500 212 1885 350 2828 100 No Hydro 1

16 2"-WP-13-412-M4AQ 2" WP 13 412 M4AQ 900 N/A 2034-11-13-10-PD-001-01 Compressor Skid V-3 NNF 59.5 1500 212 1885 350 2828 100 No Hydro 1

17 1"-WP-13-413-A3AQ 1" WP 13 413 A3AQ 150 N/A 2034-11-13-10-PD-001-01 Compressor Skid Prcess Drain 7410 59.8 ATM 194 215 230 323 100 No Hydro 1

18 1"-WP-13-414-A3AQ 1" WP 13 414 A3AQ 150 N/A 2034-11-13-10-PD-001-01 V-1, V-2 1"-WP-13-413-A3AQ 7410 59.8 ATM 194 215 230 323 100 No Hydro 1

19 1"-WP-13-415-A3AQ 1" WP 13 415 A3AQ 150 N/A 2034-11-13-10-PD-001-01 Compressor Skid Oily Water Drain Pit NNF 60 ATM 212 215 350 323 100 No Hydro 1

20 1"-WP-13-416-A3AQ 1" WP 13 416 A3AQ 150 N/A 2034-11-13-10-PD-001-01 Compressor Skid 1"-WP-13-415-A3AQ NNF 60 ATM 212 215 350 323 100 No Hydro 1

21 1"-WP-13-417-A3AQ 1" WP 13 417 A3AQ 150 N/A 2034-11-13-10-PD-001-01 Compressor Skid 1"-WP-13-415-A3AQ NNF 60 ATM 212 215 350 323 100 No Hydro 1

22 3"-VH-13-418-A3AQ 3" VH 13 418 A3AQ 150 N/A 2034-11-13-10-PD-001-01 V-1, V-2 6"-VH-13-419-A3AQ NNF 0.1 ATM AMB 215 230 323 100 No Hydro 1

10"-VH-13-172-A3AQ
23 6"-VH-13-419-A3AQ 6" VH 13 419 A3AQ 150 N/A 2034-11-13-10-PD-001-01 Compressor Skid NNF 0.1 ATM AMB 215 230 323 100 No Hydro 1
(TP-1804)

24 6"-PT-13-425-M4AQ-P 6" PT 13 425 M4AQ 900 P 2022-11-13-10-PD-004-01 6"-PT-13-403-M0UQ-P 6"-PT-13-402-M4AQ 43080 4.7 800 194 1885 250 2828 100 No Hydro 1

25 3"-VH-13-426-A3AQ 3" VH 13 426 A3AQ 150 N/A 2034-11-13-10-PD-001-01 V-3 6"-VH-13-419-A3AQ NNF 0.1 ATM AMB 215 230 323 100 No Hydro 1

26 1"-WP-13-427-A3AQ 1" WP 13 427 A3AQ 150 N/A 2034-11-13-10-PD-001-01 V-3 Oily Water Drain Pit NNF 59.8 ATM 212 215 350 323 100 No Hydro 1

Notes: Fluid Class General


1. Refer to "Project Specification Surface Preperation & Protective Coating" Doc# 8611-05-00-32-SP-311. VH = High pressure vent / Flare NNF= Normally No Flow
2. Vendor to finalize. WP = Produced Water ATM = Atmosphere
3. Current flowing wellhead pressure (FWHP) was 1302 psig as per production recorded during 11-Aug-2016. The pressure 1500 psig is considered with 15% design margin. PT = Two Phase Flow AMB = Ambient
4. Gas compressor operating range is 200-800 psig. The maximum 800 psig pressure is considered at downstream piping of pressure control valve (PCV-1827). CI = Corrosion Inhibition
5. Refer to Piping Material Specification Doc # 8611-05-00-12-SP-002 I.G = Instrument Gas