THE NATIONAL BUILDING CODE
January 1, 1979
GENERAL PROVISIONS
BUILDING OFFICIAL
enforce NBC in their jurisdiction
duties of issuing building permits
Qualifications:
a. A Filipino citizen and Good Moral Character
b. Duly registered Architect or Civil Engineer
c. Member of Accredited organization of not less than
2 years
d. At least 5 years diversified experience in building
design and construction
GENERAL PROVISIONS
CONSTRUCTION
all on-site work done from site preparation, excavation,
foundation, assembly of all the components and installation of
utilities and equipment of buildings/structure
GENERAL PROVISIONS
ERECTION
installation in place of components of a building/ structure
PD 1096
ADDITION
any new construction which increases the height or area of an
existing building/structure
GENERAL PROVISIONS
ALTERATION
construction in a building/ structure involving changes in the
materials used, partitioning, location/ size of openings,
structural parts, existing utilities and equipment but does not
increase the overall area thereof.
GENERAL PROVISIONS
RENOVATION
any physical change
made on a building/
structure to increase its
value, utility and/ or to
improve its aesthetic
quality
GENERAL PROVISIONS
CONVERSION
a change in the use
or occupancy of a
building/ structure or
any portion/s thereof
which has different
requirements
GENERAL PROVISIONS
REPAIR
remedial work done on any damaged or deteriorated portion/s
of a building/structure to restore its original condition
MOVING
the transfer of any building/structure or portion/s thereof
from its original location or position to another, either
within the same lot or to a different one
DEMOLITION
the systematic dismantling or destruction of a building/
structure, in whole or in part
GENERAL PROVISIONS
BUILDING OFFICIAL
enforce NBC in their jurisdiction
duties of issuing building permits
Qualifications:
a. A Filipino citizen and Good Moral Character
b. Duly registered Architect or Civil Engineer
c. Member of Accredited organization of not less than
2 years
d. At least 5 years diversified experience in building
design and construction
PERMITS & INSPECTION
PW
CASHIER
ISSUANCE
LINE &
GRADE
ARCHITECTURAL
RECEIVING
STRUCTURAL
& LAND USE
EVALUATION/
RECORDING & ZONING SANITARY/ APPROVAL
PLUMBING
APPLICATION
ELECTRICAL
MECHANICAL
GENERAL PROVISIONS
BUILDING PERMIT
a written authorization granted by the Building Official
to an applicant allowing him to proceed with the
construction of a specific project after plans, specifications
and other pertinent documents have been found to be in
conformity with the National Building Code and its
Implementing Rules and Regulations.
GENERAL PROVISIONS
Application form
Five (5) sets of plans and specifications prepared, signed and
sealed by duly licensed architect and engineers
For lot owners, certified true copies of:
TCT
tax declaration
current real property tax receipt
For non-lot owners, duly notarized copies of:
contract of lease
deed of absolute sale
contract of sale
GENERAL PROVISIONS
BUILDING PERMIT
NON-ISSUANCE, SUSPENSION AND REVOCATION
errors in plans and specifications
incorrect or inaccurate data supplied
non-compliance with NBC and IRRs
VALIDITY
one year from date of issue
suspension/ abandonment of construction for 120 days
GENERAL PROVISIONS
FLOOR (FULL)
MECHANICAL SPACE (FULL)
AUDITORIUM (FULL)
BASEMENT (FULL)
SUB-BASEMENT (FULL)
FOUNDATIONS (0)
GENERAL PROVISIONS
CERTIFICATE OF OCCUPANCY
REQUIRED PRIOR TO
use of building/ structure
change in use of occupancy classification
APPLICATION REQUIREMENTS
certificate of completion
logbook and Building Inspection Sheet
signed as-built plans and specifications
GENERAL PROVISIONS
CERTIFICATE OF OCCUPANCY
NON-ISSUANCE OR REVOCATION
unauthorized change, modification or alteration in plans and/or
type of construction
failure to engage services of licensed architect or civil engineer
to do full-time supervision
failure of full-time supervisor to submit logbook, Certificate of
Completion, as-built plans, specifications, Building Inspection
Sheet, fire safety Inspection Certificate
TYPES OF CONSTRUCTION
TYPE I
Wood construction
TYPE II
Wood with one-hour fire-resistive materials
TYPE III
Masonry and wood; incombustible construction for exterior
walls
TYPE IV
Steel, iron, concrete, masonry; incombustible construction for
walls, ceilings and permanent partitions
TYPE V
Structural elements of steel, iron, concrete or masonry;
building shall be fire-resistive
REQUIREMENTS OF FIRE ZONES
NON-FIRE RESTRICTIVE
FIRE-RESTRICTIVE
HIGHLY FIRE-
RESTRICTIVE
REQUIREMENTS OF FIRE ZONES
BUILDING/STRUCTURE
A 3-dimensional physical development erected within a lot or
property
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
BUILDING/STRUCTURE
A 3-dimensional physical development erected within a lot or
property
DEVELOPMENT LEVELS
Above grade
At grade
Below grade
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
LOT
The physical setting for any building whereby the level or
intensity of development covering such property is regulated by
development controls.
OCT
Original Certificate of Title
TCT
Transfer Certificate of Title
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
NEW DEVELOPMENT
New physical development within a lot that is open for
development, vacant, unutilized, development-committed or
other lots that are similarly situated
REDEVELOPMENT
Physical development consisting mainly of renovation,
rehabilitation, retrofit, upgrading, expansion within a lot or
property that is under-utilized or unfit for habitation
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
GRADE
Lowest point of elevation of finished ground surface between
exterior wall and a point 1.5m from said wall
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
FLOOR-TO-FLOOR HEIGHT
Perpendicular distance or vertical measurement between the
uppermost surfaces (finish level) of two successive floors.
STOREY
Portion of structure between the uppermost surface (finish
level) of any floor and the uppermost surface (finish level) of
the next floor above or below it.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
BUILDING FOOTPRINT
Measured horizontally from the property line to the outermost
faces of the exterior walls of the building/structure
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
PROJECTIONS
Any structurally attached portion
of a building that is outside its
outermost walls
FLOOR PLATE
Gross expanse of a wall measured
from the outermost edges of floor
slabs; may or may not be
representative of the typical floor
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
DEVELOPMENT CONTROLS
A set of inter-acting regulations concerning the physical
utilization of a lot;
Governs planning and design of spaces and the use or
occupancy of a building
a. ALLOWABLE MAXIMUM BUILDING FOOTPRINT (AMBF)
b. MAXIMUM ALLOWABLE CONSTRUCTION AREA (MACA)
c. ALLOWABLE MAXIMUM VOLUME OF BUILDING (AMVB)
d. FLOOR TO LOT AREA OR FLOOR AREA RATIO (FLAR/ FAR)
e. PERCENTAGE OF SITE OCCUPANCY (PSO)
f. IMPERVIOUS SURFACE AREA (ISA)
g. UNPAVED SURFACE AREA (USA)
h. TOTAL OPEN SPACE WITHIN LOT (TOSL)
ALLOWABLE MAXIMUM BUILDING FOOTPRINT (AMBF)
PERCENTAGE OF SITE OCCUPANCY (PSO) = Building footprint; excludes basement footprint
FLOOR TO LOT AREA OR FLOOR AREA RATIO (FLAR/ FAR) = total floor area / total lot area
PSO
ISA BASEMENT
FOOTPRINT
USA
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
FIREWALL
Reinforced masonry or RC separator w/ appropriate fire-
resistive rating and positioned between dwellings/
buildings/structures;
No openings; Cannot be shared
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
ABUTMENT
Semi-permanent or permanent structure along a property line
usually of masonry or reinforced
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
SETBACK
The horizontal distance
measured 90 degrees from
the outermost face of a
building/structure to a
property line.
INCREMENTAL
SETBACK
The horizontal distance
between the outermost
building/structure line of a
lower floor and that of a
higher floor.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
SETBACK
The horizontal distance
measured 90 degrees from
the outermost face of a
building/structure to a
property line.
INCREMENTAL
SETBACK
The horizontal distance
between the outermost
building/structure line of a
lower floor and that of a
higher floor.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
YARD
Vacant space left between the outermost face of the
building and the property lines
FRONT OF LOT
Side of a lot on which the main pedestrian and vehicular
access into the property shall be situated.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
COURT
Unoccupied space between the faces of the building lines and a
yard or another court free, open and unobstructed from the
ground upward.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
PODIUM
Fully enclosed component of the
building situated between the
established grade and the first of a
typical floor of the buildings tower
component
Not more than 12 storeys or
36meters
TOWER
Fully enclosed component of the
building situated between the
podium and roof
Not higher than 5x podium height
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
ROAD RIGHT-OF-WAY (RROW) OR STREET
Public space for continuous flow of pedestrian and vehicular traffic
that must be free from prohibited physical obstructions.
Area lying between two or more properties and its width measured
from opposite property lines
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
AIR RIGHTS
Right to physically develop and subsequently benefit or profit
from the use of air space above the RROW.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
EASEMENT
Public open space that must be absolute free from all forms of
physical obstructions that can negatively affect natural light and
ventilation or that can impede access or the full recreational use
of such space by the general public.
e.g. Waterways, Public utilities, Railroad tracks
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
SIGHTLINES
Line of view from any fixed or moving station point within a
building/structure or from any other open space to a built or
natural structure, formation or vista.
VIEW CORRIDOR
Visually unobstructed width, depth and height of all available
sightlines running through and along RROWs, easements and
open spaces.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
A - Residential dwellings
B - Residential, Hotels, Apartments
C - Education and Recreation
D - Institutional
E - Business and Mercantile
F - Industrial
G - Storage and Hazardous
H - Assembly Buildings for less than 1000 occupants
I - Assembly Buildings for 1000 or more occupants
J - Accessory
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
A - Residential dwellings
B - Residential, Hotels, Apartments (Multiple Dwellings)
C - Education and Recreation (School or day-care)
D - Institutional
Div. 1 Personal liberties are restrained. Ex. Mental Hospitals, jails, etc.
Div. 2 Nursing Homes for non-ambulatory patients
Div. 3 Nursing homes for ambulatory patients
E - Business and Mercantile
F - Industrial
G - Storage and Hazardous
H - Assembly Buildings for less than 1000 occupants
I - Assembly Buildings for 1000 or more occupants
J - Accessory
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
A - Residential dwellings
B - Residential, Hotels, Apartments
C - Education and Recreation
D - Institutional
E - Business and Mercantile
Div. 1 Gasoline Filling Station
Div. 2 Wholesale & Retail Stores
Div. 3 Aircraft Hangars
F - Industrial (ice plants, power plants, etc)
G - Storage and Hazardous (storage, hazardous & highly
flammable materials)
H - Assembly Buildings for less than 1000 occupants
I - Assembly Buildings for 1000 or more occupants
J - Accessory
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
A - Residential dwellings
B - Residential, Hotels, Apartments
C - Education and Recreation
D - Institutional
E - Business and Mercantile
F - Industrial
G - Storage and Hazardous
H - Assembly Buildings for less than 1000 occupants
Div. 1 Assembly w/ stage and occupant load < 1000
Div. 2 Assembly w/o stage and occupant load 300 or more
Div. 3 Assembly Bldg. w/o stage and occupant of < 300
Div. 4 Stadia, reviewing Stands Amusement Parks (not 1,2,3)
I - Assembly Buildings for 1000 or more occupants
J - Accessory
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
A - Residential dwellings
B - Residential, Hotels, Apartments
C - Education and Recreation
D - Institutional
E - Business and Mercantile
F - Industrial
G - Storage and Hazardous
H - Assembly Buildings for less than 1000 occupants
I - Assembly Buildings for 1000 or more occupants
J - Accessory
Div. 1 Private garages, carports, sheds
Div. 2 Fences over 1.80m high, tanks, towers
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
LOCATION ON PROPERTY
Direct access to public or open space
Projections beyond exterior walls
Buildings on same property; or with
courts
sum of areas of openings must not
exceed 50 % of sum of areas of walls
Eaves at least 750mm from side and rear
property lines
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
MAXIMUM HEIGHTS
Measured from highest
adjoining ground
surface; height
measured from lowest
surface shall not exceed
maximum by 3.00
meters
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
MINIMUM REQUIREMENTS FOR GROUP A DWELLINGS
Occupancy Corner 90%
Inside 80%
*at least 2m from property line
Sanitation At least one (1) sanitary toilet & adequate washing &
drainage
Foundation Footings 250mm thick & 600mm below ground
Floor Live Load
1st Floor 200 kilograms per sq.m
2nd Floor 150 kilograms per sq.m
*minimum
Roof Wind Load 120 min. kilograms per sq.m for vertical
projections
Stairs Clear width 750mm
Rise 200mm
Run 200mm
Entrance & Exit At least 1 entrance & 1 exit
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
MINIMUM REQUIREMENTS FOR GROUP A DWELLINGS
Location & Lot Occupancy
Light & Ventilation
Sanitation
Foundation
Post
Floor
Roof
Stairs
Entrance & Exit
Electrical Reqts.
Mechl Reqts.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
MINIMUM REQUIREMENTS FOR GROUP A DWELLINGS
Location & Lot Occupancy
Light & Ventilation
Sanitation
Foundation
Post
Floor
Roof
Stairs
Entrance & Exit
Electrical Reqts.
Mechl Reqts.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
MINIMUM REQUIREMENTS FOR GROUP A DWELLINGS
Location & Lot Occupancy
Light & Ventilation
Sanitation
Foundation
Post
Floor
Roof
Stairs
Entrance & Exit
Electrical Reqts.
Mechl Reqts.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
REQUIREMENTS FOR OTHER GROUP OCCUPANCIES
Location & Lot Occupancy
Light & Ventilation
Sanitation
Foundation
Post
Floor
Roof
Stairs
Entrance & Exit
Electrical Reqts.
Mechl Reqts.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
REQUIREMENTS FOR OTHER GROUP OCCUPANCIES
Location & Lot Occupancy
Light & Ventilation
Sanitation
Foundation
Post
Floor
Roof
Stairs
Entrance & Exit
Electrical Reqts.
Mechl Reqts.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
REQUIREMENTS FOR OTHER GROUP OCCUPANCIES
Location & Lot Occupancy
Light & Ventilation
Sanitation
Foundation
Post
Floor
Roof
Stairs
Entrance & Exit
Electrical Reqts.
Mechl Reqts.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
REQUIREMENTS FOR OTHER GROUP OCCUPANCIES
Location & Lot Occupancy
Light & Ventilation
Sanitation
Foundation
Post
Floor
Roof
Stairs
Entrance & Exit
Electrical Reqts.
Mechl Reqts.
BUILDING CLASSIFICATION BY USE &
GENERAL REQUIREMENTS
REQUIREMENTS FOR OTHER GROUP OCCUPANCIES
Location & Lot Occupancy
Light & Ventilation
Sanitation
Foundation
Post
Floor
Roof
Stairs
Entrance & Exit
Electrical Reqts.
Mechl Reqts.
LIGHT & VENTILATION
Size and Dimension of Rooms
LIGHT & VENTILATION
Air Space Requirements in
Determining the Size of Rooms
LIGHT & VENTILATION
AUTOMATIC SPRINKLERS
provided around perimeter of the opening w/in 600mm of draft
curtain.
Distance bet sprinklers: max of 1.80 center to center
ATTICS
Access: not < 600mm sq. or in diameter, min clear headroom of
800mm
Area Separation: enclosed attic space of combustible
construction shall be divided into horizontal area max of 250
sq.m. area, 750 sq.m. in area for attic with Fire-extinguishing
system
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
EXITS
Number of Exits
1. Above 1st storey: 10 occupants 2 exits
2. Mezzanine: 185 sq.m area or more than 18m in dimension
2 exits
3. 500-999 occupants: 3 exits
Exits if only 2 exits required, shall be placed distance apart not
< 1/5 of the perimeter area.
Distance of Exits
w/o sprinkler : 45m from exterior exit door
w/ sprinkler: 60m
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
DOORS
Swing: exit door shall swing to exit travel in hazardous areas w/
50 or more occupant load
Double acting doors: view panel of not < 1,300 sq. cm.
Width and Height:
1. not < 900mm in width
2. not < 2.00m in height
3. opening 90 degrees
4. exit way clear width not < 700mm
Door Leaf Width : max of 1.20
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
STAIRWAYS
Width
1. serving an occupant load of more than 50: minimum 1.10m
2. occupant load of 50 or less: minimum 900mm
3. private stairways serving an occupant load of < 10: 0.75m
Rise: max 200mm, Run: minimum 250mm
Winding Stairways narrower side of the thread 150mm 300mm
Circular Stairways used as exit w/ min width of run not < 250mm
Landings (straight run): maximum of 1.20m vertical
Distance bet landings max of 3.60m vertical distance
Handrails: not < 800mm nor more than 900mm.
Headroom clearance: 2.00m
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
SEATS
Seat Spacing (spacing of rows of seats from back to back):
minimum 840mm (standard seating)
Clear width of rows (continental seating) as follows:
1. Rows of 18 seats: 450 mm
2. Rows of 35 seats or less: 500mm
3. Rows of 45 seats or less: 520mm
4. Rows of 46 seats or more: 550mm
Width: min 450mm, max of 480mm
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
FIRE-EXTINGUISHING SYSTEMS
Every storey, basement or cellar:
1. w/ 200sq.m or more w/c is used for habitation, etc.
2. w/c has an occupant load of more than 20
Dressing, rehearsal rms., workshops or factories w/ occupant load
of more than 10 and assembly halls w/ occupant load of more than
500, if the next doors of rooms are more than 30.00m from safe
dispersal area.
Photographic x-ray, nitrocellulose films and inflammable articles
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
DRY STANDPIPES (for bldgs. w/ 4 or more storeys)
Construction and Test: shall be wrought iron of GS w/ fittings,
connections to withstand 20 kg per sq.cm of water pressure
Size: 900 liters water per minute
Number Required: every 4 or more storeys where any floor above
3rd floor is 950m or less, equipped w/ 1 dry standpipe.
Siamese Connections:
1. 2 way: 100mm dry standpipe
2. 3 way: 125mm
3. 4 way: 150mm
Siamese inlet (located on street front): Not < 300mm or more than
1.20m above grade
Outlets: standpipe 63mm outlet not more than 1.20m above each
floor level, with 2 way standpipes 63mm outlet above the roof (all
with gate valves)
GENERAL DESIGN AND
CONSTRUCTION REQUIREMENTS
WET STANDPIPES
Size: Interior wet standpipes deliver 190 liters/water per minute
under 2.0 kg per sq.cm water pressure
Outlets: 38mm valve each storey located not less than 300mm nor
more than 1.20m above the floor.
Water Supply street main: not < 100mm in diameter
ELECTRICAL & MECHANICAL
REGULATIONS
PREFABRICATED ASSEMBLY
a structural unit, the integral parts of which, have
been built up or assembled prior to incorporation in
the building
PLASTICS
structural hazards
fire hazards
hazardous electrical wiring
hazardous mechanical installation
inadequate sanitation and health facilities
improper occupancy and architectural eyesore
improper location
illegal construction
ACCESS STREETS, ROADS, ALLEYS
TYPE
Perpendicular or Diagonal
Parking (2.50 x 5m)
SPECIAL PROVISIONS
1 parking slot for the handicapped per 50 up to 150 parking slots
& an additional slot for every 100 slots thereafter.
Wheel chair transfer area one between 2 spaces, directly
connect to accessible walk of travel and bldg entrances.
Maximum distance of accessible parking area from facility
served. Parking areas for handicapped shall be w/in 60m of the
facility being served
RATIONALE FOR LAWS
Order
Protection of the public interest
Not everything can be left to market forces
Equitable distribution of welfare and resources
Competencies required
Bureaucratic convenience
DEMERITS
Vague definition of public interest
Irrelevance to context
Inflexibility
Social Polarization
Confiscatory
High cost of enforcement