Вы находитесь на странице: 1из 7

ERU

Energy Recovery Units

Production or custom design


Package or split system
Energy recovery: heat pipe,
air to air, air to water, heat
wheels
ETL labeling available
Powder coated

Manufacturer of Quality Air Moving Equipment


ERU
Energy Recovery Units

Super Efficient Energy Recovery Units


5,000 to 40,000 CFM and higher
Why? Energy recovery: heat pipe, air
Designed specifically for high outside to air, air to water, heat wheels
air capacity requirements and up to Engineered primarily for high
60% savings in cooling cost, ease outside air requirements:
of maintenance, and quality 30%100%
construction, United Metal Products' Powder coated
Energy Recovery Units (ERU) is the ETL labeling available
Resources Available for This Product
cool solution. In applications where
energy recovery is needed in colder Applications: Catalog By Mail
climates, our Energy Recovery Units Airports Catalog Online
can be fitted with cross flow, heat Clean rooms
pipe, or heat wheel exchangers as Factories
required by engineers. These energy Hospitals
recovery units are "super efficient", Kitchens United Metal Products
1920 E Encanto Drive Tempe, AZ 85281
ranging from 60% to over 100% Prisons
T 480.968.9550
effective in high dry bulb Terminals
F 480.968.9555
applications. They are available in Call centers www.unitedmetal.com
either production or custom design. Convention centers
Indoor Pools
Design Options: Offices
0-100% outside air Schools
5,000 to 40,000 CFM and higher Theaters
Production or custom design Casinos
Package or split system

Manufacturer of Quality Air Moving Equipment


ERU
Energy Recovery Units

Yearly Cooling Demand

40,000
United Metal Products, the leading
manufacturer of industrial and
30,000
commercial air handling equipment
in the Southwest, is introducing a
revolutionary new productERU.
Energy kWh

20,000 The key to this breakthrough is as


old as the millenniumevaporative
cooling. The ERUs unique
10,000
configuration captures this simple,
yet powerful, principle.

0
May
Mar

Aug

Nov

Dec
Sep
Jan

Jun
Feb

Apr

Oct
Jul

Package A.C. ERU


SEA Comparison ProgramDOE-2 basis of analysis for Phoenix, AZ
Building Description: 100 feet wide X 100 feet deep

The Wet Bulb Energy Recovery System


Energy recovery over the past
decade has been largely centered
around sensible recovery. Although
this works well in the colder
DB WB
climatic regions of the world, it has
108 / 70
not been as effective in areas
Outside
where higher dry bulb
Air Temp
temperatures exist. The principle is
simpleexchanging temperature
at the wet bulb level can increase
efficiency by more than 50% over a
Scavenger DB WB DB WB Leaving
Air Temp 80 / 67 62.6 / 60.7 Air Temp standard dry bulb exchanger. This
means big savings for the building
Location 1% Coincident Indirect LAT Direct LAT owner.
Dry Bulb Wet Bulb Dry Bulb Wet Bulb Dry Bulb Wet Bulb
Albuquerque, NM 93 60 68.3 51.3 53 51.3
Denver, CO 90 59 66.8 50.6 52.2 50.6 Designed specifically for high
El Paso, TX 98 64 72.5 55.3 57 55.3 outside air capacity requirements
Los Angeles, CA 81 64 68.3 59.4 60.3 59.4
Las Vegas, NV 106 66 76 55.6 57.6 55.6 and up to 60% savings in cooling
Phoenix, AZ 108 70 79.5 60.7 62.6 60.7 cost, ease of maintenance, and
Sacramento, CA 97 69 76 62 63.4 62 quality construction, United Metal
Salt Lake City, UT 94 62 70 53.6 55.2 53.6
San Jose, CA 89 66 71.8 60 61.2 60 Products ERU is the cool solution.

Information subject to change. Updates available online.


Manufacturer of Quality Air Moving Equipment MFC//CHARTS//Rev. 1.0 08-25-03
ERU
Energy Recovery Units

Production ERU Layout Styles #1 thru #16


OPTIONAL ELECTRICAL
70"
OUTSIDE TO DRAIN AND OVERFLOW
10" TO FILL, DRAIN
AIR
AND OVERFLOW 32"
TO COIL DRAIN

DIRECT EVAP COOLING OPTION

CW OR DX OPTION
COIL DRAIN PAN
SCAVENGER AIR SUPPLY AIR

HW OPTION
AIR DUCT DUCT W

ID COIL
e a

CW OR DX OPTION
TOWER
EXHAUST

HW OPTION
OA
DIRECT EC
OPTION

ID COIL
H

b d
SUUPLY AIR
DUCT
h
SCAVENGER
AIR DUCT

Air Volume (CFM) 5,000 10,000 15,000


Supply ESP (available at higher S.P.) ("WG) 0.5 0.5 0.5
Supply Motor: HP / Volt/Phase/Hz / Amps 5 / 460/3/60 / 7.6 7.5 / 460/3/60 / 11 15 / 460/3/60 / 21
Unit Dimesions (inches) - see drawing. Dimensions shown in parenthesis apply when Direct Evap Cooling option is included.
Overall Unit Length (L) 197.50 (228.00) 197.50 (228.00) 197.50 (228.00)
Overall Unit Width (W) 60.00 96.00 96.00
Overall Unit Height (H) 58.00 58.00 76.00
Supply Air Duct Width (a) 14.70 19.75 27.25
Supply Air Duct Height (b) 15.88 24.75 27.25
Supply Air Duct Location (c) 22.65 38.12 34.38
Supply Air Duct Location (d) 67.62 (98.12) 58.75 (89.25) 56.25 (86.75)
Scavenger Air Duct Width (e) 24.00 60.00 60.00
Scavenger Air Duct Height (f) 24.00 24.00 24.00
Scavenger Air Duct Location (g) 30.00 30.00 30.00
Scavenger Air Duct Location (h) 98.50 (129.00) 98.50 (129.00) 98.50 (129.00)
Return Air Duct Height (i) N/A N/A N/A
Return Air Duct Location (j) N/A N/A N/A
Shipped Weight (Lb) * 4,300 (5,150) 5,200 (6,200) 5,600 (6,750)
Operating Weight (Lb) * 5,500 (6,700) 6,500 (7,900) 7,000 (8,550)
* Weights based on indirect cooling option only (and direct evaporative cooler option shown in parenthesis). Weights will change as HW coil, CW coil and DX
coil are added. Establish actual unit weight before calculating structural loadings. Specifications subject to change without notice.

Information subject to change. Updates available online.


Manufacturer of Quality Air Moving Equipment ERU//LAYOUT 1-16//Rev. 1.0 08-25-03
ERU
Energy Recovery Units

Production ERU Layout Styles #17 thru #80


87" WITH DIRECT EC OPTION
OPTIONAL ELECTRICAL 56" WITHOUT DIRECT EC OPTION
OUTSIDE OUTSIDE TO COIL DRAIN
10" TO FILL, DRAIN AIR AIR 49.00
AND OVERFLOW TO DRAIN
AND OVERFLOW

DIRECT EVAP COOLING OPTION


CW OR DX OPTION
SCAVENGER AIR SUPPLY AIR

HW OPTION
AND/OR RETURN DUCT

ID COIL
W
AIR DUCT a
e

L
CW OR DX OPTION

TOWER
HW OPTION

DIRECT EC
EXHAUST b ALTERNATE
OPTION
ID COIL

H
SUPPLY AIR
DUCT
d

d
b
SUPPLY AIR
DUCT
j
RETURN AIR
DUCT
h
SCAVENGER
AIR DUCT

Air Volume (CFM) 5,000 10,000 15,000


Supply ESP (available at higher S.P.) ("WG) 0.5 0.5 0.5
Supply Motor: HP / Volt/Phase/Hz / Amps 5 / 460/3/60 / 7.6 7.5 / 460/3/60 / 11 15 / 460/3/60 / 21
Unit Dimesions (inches) - see drawing. Dimensions shown in parenthesis apply when Direct Evap Cooling option is included.
Overall Unit Length (L) 233.50 (264.00) 233.50 (264.00) 233.50 (264.00)
Overall Unit Width (W) 60.00 96.00 96.00
Overall Unit Height (H) 58.00 58.00 76.00
Supply Air Duct Width (a) 14.70 19.75 27.25
Supply Air Duct Height (b) 15.88 24.75 27.25
Supply Air Duct Location (c) 22.65 38.12 34.38
Supply Air Duct Location (End / Down) (d) 19.75 / 8.00 26.64 / 8.00 27.38 / 8.00
Scavenger Air Duct Width (e) 24.00 60.00 60.00
Scavenger Air Duct Height (f) 24.00 24.00 24.00
Scavenger Air Duct Location (g) 30.00 30.00 30.00
Scavenger Air Duct Location (h) 134.50 (165.00) 134.50 (165.00) 134.50 (165.00)
Return Air Duct Height (i) 24.00 24.00 24.00
Return Air Duct Location (j) 95.50 (126.00) 95.50 (126.00) 95.50 (126.00)
Shipped Weight (Lb) * 4,600 (5,450) 5, 500 (6,500) 5,900 (7,050)
Operating Weight (Lb) * 5,800 (7,000) 6, 800 (8,200) 7,300 (8,850)
* Weights based on indirect cooling option only (and direct evaporative cooler option shown in parenthesis). Weights will change as HW coil, CW coil and DX
coil are added. Establish actual unit weight before calculating structural loadings. Specifications subject to change without notice.

Information subject to change. Updates available online.


Manufacturer of Quality Air Moving Equipment ERU//LAYOUT 17-80//Rev. 1.0 08-25--03
ERU
Energy Recovery Units

5 Scavenger air exhausted from Stainless steel sump & pumps


Custom ERU building by cooling tower fan Aluminum cabinet (for reduced
Standard Features 5 Return air recirculation operating weight)
All items listed here are a sample of 5 Fully weatherproof Stainless steel cabinet
what is typical. As these systems 5 4" double drainable weather 2" double wall cooling tower
are custom built to site louver with bird screen Single point power connection
requirements in construction and 5 Fan door mechanical safety locks with electrical transformers &
performance they will be unique. 5 Pre-wired motors and pumps to a magnetic motor starters
We can include almost any single external junction box Discharge temperature control
component items into a unit Building static pressure control
whether they are listed here or not: Custom ERU Total integration with building
5 16ga pre-painted steel single skin management systems
cooling tower casing and double Optional Features Internal lights with
wall supply air casing Split or packaged systems weatherproof switch
5 Smooth or perforated inner liners designed and built to customer GFI receptacle
with 1" or 2", 1.5# or 3# insulation requirements Fan door safety disconnect
5 Fans can be ordered for up, 16ga G-90 galvanized single skin switches
down or horizontal discharge casing with tough powder coated Automatic flush kit with timer
5 Fans have powder coated fan finish to casing-baked at 375F Automatic drain-down with
housing, heavy duty L-50 200,000 HW or steam heating coils timer
hour bearings, belts & pulleys- CW or DX cooling coils Automatic drain-down & freeze
fully installed, aligned and Direct evaporative cooling protection with timer
tensioned, 1" deflection springs, Air-to-air plate heat exchangers - Roof curb-flat or pitched,
anti-vibration mounts with with or without insulated or uninsulated
seismic restraints and flexible bypass/recirculation dampers
connector Heat wheels - either total heat or Typical Applications
5 460v/3ph/60Hz ODP standard sensible heat transfer available Airports
efficiency motors on adjustable Heat pipes Call centers
motor slide base Steam humidifiers Casinos
5 Double-wall hinged access doors Gas heating Clean rooms
5 Cooling Towers have fully welded Sound attenuation Convention centers
and painted G-90galvanized HEPA filtration Factories
sump and media support with up Filter pressure differential gauge Hospitals
to 36" thick CELdek evaporative or switch Indoor Pools
cooling media (not available with 90% efficient GLASdek UL900 Kitchens
ETL label) Class 2 evaporative media for ETL Offices
5 Heavy duty cooling tower pumps labeled units per UL 1995 Prisons
with adjustable water flow, bleed standard Schools
lines and pipe work clean-out Premium efficiency ODP or TEFC Terminals
points motors Theaters
5 6 or 8 Row indirect cooling coils Extended fan bearing lubrication
with 5/8" copper tubes and lines
aluminum fins Fan bearings upgraded to L-10
5 Schedule 80 PVC or copper 200,000 hours
piping for water distribution Fan belt guards
between cooling tower and Safety door screens
indirect coil 2" deflection spring anti-vibration
5 2" 30% panel filters plus bag or mounts with seismic restraints
cartridge filters (front or side Stainless steel evaporative media
access) holding rack

Information subject to change. Updates available online.


Manufacturer of Quality Air Moving Equipment ERU//custFEATURES//Rev. 1.0 08-25-03
ERU
Energy Recovery Units

Production ERU Production ERU Typical Applications


Optional Features Airports
Standard Features Call centers
5 16ga pre-painted steel single skin 16ga G-90 galvanized single skin Casinos
cooling tower casing and double casing with tough powder coated Clean rooms
wall supply air casing finish to casing-baked at 375F Convention centers
5 Smooth or perforated inner liners HW or steam heating coils Factories
with 1" or 2", 1.5# or 3# insulation CW or DX cooling coils Hospitals
5 Fans can be ordered for down or Direct evaporative cooling Indoor Pools
horizontal discharge Filter pressure differential gauge Kitchens
5 Fans have powder coated fan or switch Offices
housing, heavy duty L-50 200,000 90% efficient GLASdek UL900 Prisons
hour bearings, belts & pulleys- Class 2 evaporative media for ETL Schools
fully installed, aligned and labeled units per UL 1995 Terminals
tensioned, 1" deflection springs, standard Theaters
anti-vibration mounts with Premium efficiency ODP or TEFC
seismic restraints and flexible motors
connector Extended fan bearing lubrication
5 460v/3ph/60Hz ODP standard lines
efficiency motors on adjustable Fan bearings upgraded to L-10
motor slide base 200,000 hours
5 Double-wall hinged access doors Fan belt guards
5 Cooling Towers have fully welded Safety door screens
and painted G-90galvanized 2" deflection spring anti-vibration
sump and media support with 24" mounts with seismic restraints
thick CELdek evaporative Stainless steel evaporative media
cooling media (not available with holding rack
ETL label) Stainless steel sump & pumps
5 Heavy duty cooling tower pumps Aluminum cabinet (for reduced
with adjustable water flow, bleed operating weight)
lines and pipe work clean-out Stainless steel cabinet
points 2" double wall cooling tower
5 6 Row indirect cooling coils with Single point power connection
5/8" copper tubes and aluminum with electrical transformers &
fins magnetic motor starters
5 Schedule 80 PVC piping for water Discharge temperature control
distribution between cooling Building static pressure control
tower and indirect coil Internal lights with weatherproof
5 2" 30% panel filters (side access) switch
5 Scavenger air exhausted from GFI receptacle
building by cooling tower fan Fan door safety disconnect
5 Return air recirculation (styles 17 switches
- 80 only) Automatic flush kit with timer
5 Fully weatherproof Automatic drain-down with timer
5 4" double drainable weather Automatic drain-down & freeze
louver with bird screen protection with timer
5 Fan door mechanical safety locks Roof curb-flat or pitched,
5 Pre-wired motors and pumps to a insulated or uninsulated
single external junction box