Вы находитесь на странице: 1из 7

Guidelines while installing the Softwares

1.Install Windows 2.Install 3.Install-Engin


Installer 3.1 .NET ( dot net) diagnostic
Tool

4. Install ECU 5. Copy Hex file 6. Copy


flash tool Vinlookupfile.ini

7. Install 8. Install
Immobilizer MBFM 9.Install DIS
Flash Tool
Diagnostic Diagnostic
Tool Tool

1. Click on the file WindowsInstaller-KB893803-v2-x86. Checking and loading


takes few minutes.
2. In the dotnet driver folder click on the file dotnetfx35. Note that this will take
some time ( up to 10 minutes)
3. Click on to the file MahindraDiagnosticTester_1_1. Follow the instructions.
4. Click on to the folder ECU flash tool. Click on to the Setup file. Follow the
instructions.
5. After loding the ECU flash tool, click on to the Hexfile folder, copy all the Hexfliles
on to C:\Program Files\ECUFlashTool\Hexfile
6. Click on to the folder Vinlookup. Copy the file VINLookupField.ini in C:\Windows
folder
7. Click on to the Immobilzer tool. Click on to the Setup file.
8. Open the MBFM folder, there are two file, click on the Setup.
9. Open the Folder DIS Flashing Tool. In that there is a folder called
MnMFlash_4.0_Jan07_2009. Click on to the Setup file.

Note: If the python is not upgraded one then the ECU flashing on the vehicle is not
be possible. In such a condition the Python hardware upgrade software has to be
used. The detailed instructions are given below
Steps to upgrade Smart (Python) firmware

1. Create a folder in C:\python

2. Copy the Python1Bsetup9_02_01M.zip in C:\python folder

3. Double click on Python1Bsetup9_02_01M.zip and Extract the files to same folder.

4. Folder by name Python1Bsetup9_02_01M will be created.

5. Open the folder Python1Bsetup9_02_01M and double click on the file named
Python1Bsetup.EXE.

6. Start Installation

7. While installing, note the Destination folder path.


8. Finish the Installation.

9. Go to Destination folder path and check the below files on Right side.

10. Double click on PythonReflash.exe

11. Click on Configuration


12. Click on Auto Detect and it will automatically detect the Python, message should
appear as below.

13. Click Ok.

14. Click on Select Firmware File Button and Select the file Python_1B_Firmware.pfw
(eg: C:\Python1B2534v0404\ Python_1B_Firmware.pfw) as shown in the below figure.
15. Select the file and click open.

16. Click OK

17. Click on Reflash button.

18. After clicking on Reflash button, the progress bar will appear below and dont reset
the python while flashing.

19. Once flashing is done, the following message will appear.


20. Click ok.

21. Close the window.

22. Go to the Folder C:\Python1B2534v0404 and double click on


Python1B2534SDK.exe

23. Then select PassThruOpen command under J2534 Commands menu as below:
24. Then you have to select PassThruReadVersion command under J2534 Commands
menu and verify that the firmware details as shown below are displayed.