Вы находитесь на странице: 1из 6

BITZER Output data

Created on : 24.05.2016 21:48:51


condensator

BITZER Software v6.4.0 rev1076 24.05.2016 / All data subject to change. 2/6

Table of content

Project survey............................................................................................................................................................ 3
Compressor Selection: Condensing Units................................................................................................................. 4
Technical Data: LH114/4CES-9Y.............................................................................................................................. 5
Condensing Units...................................................................................................................................................... 6
condensator

BITZER Software v6.4.0 rev1076 24.05.2016 / All data subject to change. 3/6

Project survey
Selected compressors
Condensing Units 1x LH114/4CES-9Y
condensator

BITZER Software v6.4.0 rev1076 24.05.2016 / All data subject to change. 4/6

Compressor Selection: Condensing Units

Input Values
Unit type LH114/4CES-9Y
Series Standard
Refrigerant R134a
Reference temperature Dew point temp.
Evaporating SST -7,50 C
Ambient temp. 30,0 C
Suction gas temperature 20,00 C
Useful superheat 100%
Operating mode Auto
Power supply 400V-3-50Hz
Capacity Control 100%

Result
Unit type LH114/4CES- 9Y-40S
Capacity steps 100%
Cooling capacity 12,30 kW
Evaporator capacity 12,30 kW
Power input * 3,98 kW
Current (400V) 8,32 A
Voltage range 380-420V
Mass flow 265 kg/h
Condensing SDT 39,0 C
Liquid subcooling 3,00 K
Operating mode Standard

Tentative Data.
*Power input compressor, power input fan see ''T. Data''

Application Limits

Legend
additional cooling

suction gas superheat >10K

M1: motor 1

M2: motor 2
condensator

BITZER Software v6.4.0 rev1076 24.05.2016 / All data subject to change. 5/6

Technical Data: LH114/4CES- 9Y


Dimensions and Connections

Technical Data
Technical Data
Weight 217 kg
Total width 1356 mm
Total depth 920 mm
Total height 773 mm
Connection suction line 28 mm - 1 1/8''
Connection liquid line 16 mm - 5/8''
Fans: Number 2
Voltage (more on request) 230V-1-50Hz (Standard)
Current / Power consumption of each fan 1,41 A / 301 W
Air flow condenser 50Hz 7804 m/h
Voltage (more on request) 230V-1-60Hz (Standard)
Current / Power consumption of each fan 1,93 A / 445 W
Air flow condenser 60Hz 8904 m/h
Coil Volume 12,0 dm3
Receiver type (Standard) F152H
Max. refrigerant charge 90% at 20C
R22 16,3 kg
R134a 16,6 kg
R407C 15,6 kg
R404A/R507A 14,4 kg
Receiver type (Option) F302H
R22 32,7 kg
R134a 33,1 kg
R407C 31,3 kg
R404A/R507A 28,8 kg
Extent of delivery (Standard)
Discharge line Standard
Protective charge Standard
Available Options
Oil separator Option
Check valve Option
High & low pressure switch Option
Dressed unit Option
Weather protective housing Option
Fans: elect. Speed control Option
Sound measurement
Sound power level (-10C / 45C) 81,5 dB(A) @ 50Hz
Sound pressure level @ 1m (-10C / 45C) 73,5 dB(A) @ 50Hz
Data of compressors: see compressor program
condensator

BITZER Software v6.4.0 rev1076 24.05.2016 / All data subject to change. 6/6

Condensing Units
Motor 1 = e.g. LH../4TES-12 (4T-12.2) with 12"HP", primary for air-conditioning (e.g. R22,R407C) and medium
temperature application (e.g. R134a, R407F, R407A, R404A, R507A, R22) and air-conditioning with R134a at high
ambient temperatures
Motor 2 = e.g. LH../4TES-8 (4T-8.2) with 8"HP", for medium and low temperature application (e.g. R134a, R407F,
R407A, R404A, R507A, R22) and air-conditioning with R134a.
For more information concerning the application range use the "limits" button.

Operation modes for LH../4VES-7 (4Z-5.2) to LH../6HE-25 (6H-25.2) with R22:


CIC = liquid injection with low temperature application, suction gas cooled motor

Specifications for sound emission Ecostar:


The data are based on 50Hz operation with R404A
Soundpressure: Data are valid for free field conditions according to EN13487 with a block-shaped reference area in a
distance of 10m.
For further informations see technical information for sound data.

Legend of connection positions according to "Dimensions":

1 Suction valve
2 Discharge gas line
3 Cndensate line
4 Refrigerant outlet
5 Pressure relief valve connection