LIST OF ATTACHED TECHNICAL DATA SHEETS


Title AADC STANDARD CODE
CABLES AND ACCESSORIES
11 kV XLPE-Insulated Three-Core Under Ground
D-AA-CAB-11-3C-95&120&185&240&300
Cables (3x95mm2 or 3x120mm2 or 3x185mm2 or
(Rev.2-2010)
3x240mm2 or 3x300 mm2)
11 kV XLPE-Insulated Underground Cable
D-AA-CAB-ACC-11 (Rev.0-2010)
Accessories
LV XLPE-Insulated Underground Cable
D-AA-CAB-ACC-LV (Rev.0-2010)
Accessories
Fibre Optic Underground Cables (144 Fibres) D-AAA-CAB-FOC-DB-144
Directly Buried. (Rev.0-2010)
Fibre Optic Cable Accessories D-AA-CAB-ACC-FOC (Rev.0-2010)
LV XLPE-Insulated Four-Core Underground Cables
D-AA-CAB-LV-BCT-4C-4upto240 (Rev.0-
(Installed in Buildings/Concrete Trenches)
2010)
(from 4x4mm2 or 4x6mm2 .. up to 4x240mm2)
LV XLPE-Insulated Four-Core Underground Cable
(Directly Buried) D-AA-CAB-LV-DB-4C-4upto240 (Rev.0-2010)
(4x4mm2 or 4x6mm2 upto 4x240mm2)
LV XLPE-Insulated Single-Core Underground
D-AA-CAB-LV-DB-SC-95upto630 (Rev.0-
Cables (Directly Buried)
2010)
(1x95mm2 up to 1x630mm2)
VTs, CTs, Meters
Analogue Indicating Instruments D-AA-MET-AI (Rev.0-2010)
Current Transformers for Energy Meters D-AA-MET-VTCT-CT (Rev.0-2010)
Voltage Transformers for Energy Meters D-AA-MET-VTCT-VT (Rev.0-2010)
Three-Phase Direct Connected Static Energy Meter D-AA-MET-STEM-DC-3P-1 (Rev.0-2010)
Class 1
Electric Measuring Transducers D-AA-MET-TRAD (Rev.0-2010)
MV SWITCHGEAR Current Transformer (11 kV) D-AA-SWG-MV-VTCT-CT-11 (Rev.0-2010)
MV SWITCHGEAR Voltage Transformer (11 kV) D-AA-SWG-MV-VTCT-VT-11 (Rev.0-2010)
11/0.4kV DISTRIBUTION SUBSTATION
MV SWITCHGEAR 11/0.4 kV Distribution D-AA-SWG-MV-DIST-11-FIXED-0.4-DC
Substation (Rev.0-2010)
(FIXED 11 kV CB Type-DC)
MV SWITCHGEAR 11 kV Switching D-AAA-SWG-MV-SWST-WD
Station(FIXED 11 kV CB's) (Rev.0-2010)
LV MAIN DISTRIBUTION BOARD
0.4 kV Distribution Boards for 11 or 22/0.4 kV D-AAA-SWG-LV-DIST-BOARD-0.4-PUBL
Distribution Substation (Public) (Rev.1-2010)
SUBSTATION AUXILLIARY EQUIPMENT
Station 48 V DC Distribution Board D-AA-AUX-48V-DC-BOARD (Rev.0-2010)
48 V Battery (NiCad) and Charger, Single D-AA-AUX-BAT&CH-NiCad-48-S (Rev.0-
Configuration
TRANSFORMERS
TRANSFORMERS / REACTORS / RESISTORS D-AA-TRAFO-ATR-OIL-11_1500 (Rev.0-
Auxiliary/Distribution Transformers (Floor 2010)
Mounted Oil-Insulated)1500 kVA, 11 5%/0.415
kV
EARTHING LIGHTING
Earthing/Grounding Systems D-AA-EARTH-GROUND (Rev.0-2010)
CIVIL WORKS
Horizontal Directional Drilling (HDD) D-AA-CIV-CAB-HDD (Rev.0-2010)
CONTROL PROTECTION - SUPERVISIOIN
MV/LV Substation Protection Schemes D-AA-CPS-MV-LV-PROT (Rev.0-2010)
Allocation of Signals for Distribution Substations 355099718
Allocation of Signals for Switching Stations 355099718
CUBICLES AND ENCLOSURES
Panels, Cubicles, Marshalling Boxes & Enclosures
for Control, Protection, Communication & D-AA-CUB (Rev.0-2010)
Auxiliary Equipment