Академический Документы
Профессиональный Документы
Культура Документы
Industry Solutions
Huawei Access Network
Industry Solutions
CONTENTS
Industry Leader 1
CPN 4
Background 4
Solution Overview 5
Product Overview 6
Success Story 7
Smart Hotel 9
Background 9
Solution Overview 10
Product Overview 10
Success Story 11
uniSite Cabinet 27
Success Stories of Huawei Access Network 28
Access Network Full Portfolio Devices 29
Access Network Full Portfolio Auxiliaries 30
Industry Leader
As a global leader of optical access solutions, Huawei has the world's largest access product and
solution team, as well as over 13 years' project delivery experience. Huawei's access products
and solutions have served the major enterprises of various industries and telecom operators.
Having ranked No. 1 by global market share for 9 successive years, Huawei is a trustworthy
partner for your business.
Standard Developer
Chair Huawei
Frank Effenberger
XG-PON1
GPON NG-PON2 G.Multi
Maintain
Technical Leader
2014 Q1 Deployed the first 40G TWDM-PON commercial network with Etisalat.
Huawei's Market Share by PON Port Quantity Huawei's Market Share by Broadband Access Port Quantity
Huawei Huawei
1st 54% 1st 45%
2013 2013
Source: Infonetics Source: Infonetics
CPN Surveillance
Power grid
Hotel Broadcast
CPN
CPNs include scenarios such as office intranets, enterprise campus, public area coverage, as well as residential premises.
As CPNs are evolving from the traditional telephony networks toward Internets and the Internet of Things, service
requirements are also diversifying from the unitary telephony service into multimedia applications. The high-bandwidth,
wide-coverage, and multi-service all-optical access has become the mainstream choice for building CPNs. ..
Higher bandwidth, smooth evolution: Bandwidth-intensive services require networks to support large-capacity access and
continuous smooth evolution.
All scenarios, more services: Scenarios encompass offices and surveillance, as well as voice services and the Internet of Things.
Services are diversifying.
Protecting investment, reusing resources: The new networks should fully reuse the existing lines and auxiliary resources on
the campus, thereby protecting the customers' investment.
Huawei develops the industry-leading PON access solution for enterprises to build an all-optical network that features flexible
access, high quality of experience, and efficient OAM. The solution covers the following scenarios on the enterprise campus:
enterprise office and production, residential community, video surveillance, video conferencing, wireless coverage, bulletins, and
access control systems.
Campus
management platform
Core
Private cloud
Extranets
or other systems
Switch
OLT
Optical splitter
ONU ONU
ONU ONT
DIGITAL
AP
Information Mobile
VoIP Video conferencing PC Voice Cameras exchange terminals terminals Voice TV PC
Campus access network scenarios can be divided into office network, public facility network, and home network. Office networks
use FTTO-type ONUs to carry voice, broadband Internet access, video conferencing, and private line services. Public facility networks
use indoor and outdoor ONUs to provide access control, surveillance, and Wi-Fi services. Typical home networks are those that use
ONTs to carry triple play services.
Solution Highlights
No.1 Flexible network
Multiple services carried over one PON network, network decoupled from services; service quality ensured through traffic
classification and HQoS.
Flexible capacity expansion; heterogenous network that supports PON, 10G PON, and 40G PON on the same platform.
Platform Highlights
Superb aggregation performance: 3.2T backplane, 1920G switching capacity, and a maximum of 512K MAC addresses
Unified platform: integrated fiber and copper access platform; service boards compatible across the platform
High-reliability links: type A/B/C/D link protection, ensuring reliable running of services
High-reliability devices: control boards in 1+1 backup, power boards in 1+1 backup, improving system reliability
Layer 3 routing: Layer 3 intercommunication, enabling ONUs connected to the same OLT to intercommunicate at Layer 3 and
saving public network IP addresses
High density: 16 PON ports per board, high density and low power consumption, in line with the "larger capacity and fewer
sites" trend
All-Scenario ONUs
Appearance
Various specifications Outdoor integrated design Positioned for small Positioned for home users
Highlight A rich range of interfaces Harsh-environment-proof enterprises or villa Rich combinations of
Indoor installation Easy to install subscribers interfaces
Solution
Challenges to the Customer
Based on the requirements of the Daqing oilfield enterprise
The switch and DSLAM networks of Daqing Telecom have and residential community, Huawei provides two PON access
been running over a decade. Owing to the long service solutions for the customer: FTTB and FTTH.
time, safety risks exist and some components of the devices
are having supply difficulties. For reconstruction of old residential communities, the actual
The DSLAM system is falling short of the broadband service installation rate is high, and FTTB allows users to share the
development demands. same ONU, so the account-opening cost per line is lower than
Operators such as China Unicom and China Telecom are that of FTTH. In addition, abundant copper line resources
MDU
MA5600T Internet
MA5626
FTTB
MDU
OLT NGN
Private
network
MA5620
MA5600T U2000
ONT
ONT FTTH
ONT
OLT Server
have been deployed in the buildings. Therefore, meeting OAM and driving down TCO.
bandwidth requirements, FTTB at the same time has more Devices, services, and lines are deployed using 1+1
advantages regarding costs and deployment. By comparing the redundancy, greatly improving network reliability.
combinations of technology+costs, the customer chooses FTTB. Many modules are pre-connected for deployment, thereby
reducing operation difficulty, especially when there is heavy
For new residential communities, the actual installation rate is workload for service provisioning.
low, and copper line resources are not deployed. Considering
FTTB/FTTH hybrid network allows for flexible bandwidth
the costs and the future technology trend, Huawei recommends configuration. Services are provisioned and deployed in a
FTTH to the customer. unified manner over the entire network.
Balance is well achieved between technology and business,
producing the most cost-effective solution for the customer.
Benefits for Customer
The converged communications network anticipates future
Devices on the live network are centrally managed through development requirements and is in line with China's
the powerful NMS platform, significantly simplifying system 3-network convergence strategy.
Smart Hotel
Hotel services are evolving from the traditional room telephone service to multimedia application and
informatization, which is diversified, intelligent, and mobile-based. Such characteristics bring new challenges to the
communications network system of hotels. The "GPON & network convergence" philosophy is critical for hotels to
remove the traditional network restrictions and quickly deploy all services.
Huawei has in-depth understanding of the construction requirements of hotel communications networks. Based on the
requirements for comprehensive converged services such as wireless, cable, video, voice, and guest room control services, Huawei
puts forth the all-optical smart hotel notion, and innovates the "one line and N services for one room" room service model, thereby
developing the state-of-the-art intelligent communications solution for hotels.
AP
Switch OLT
ONU Surveillance phone
Phone
ONT
Equipment room Telecom riser Corridor Hotel room
Solution Highlights
No.1 One fiber for each room
FTTH is deployed for hotel rooms. One fiber is routed to each room, avoiding the high costs that may have risen from multi-
system and multi-cable dropping in a traditional network.
All-Scenario ONUs
Appearance
Various specifications
Positioned for small enterprises or hotel
Highlight A rich range of interfaces Rich combinations of interfaces
customers
Indoor installation
Customer Requirements
Fibers routed to villas, providing ultra-high bandwidth Ubiquitous wireless network, allowing customers to Control of hot spring, air-conditioners, curtains, and
and Internet surfing at high speeds. enjoy hotel service anywhere any time. light through smart terminals.
Also, the 1:128 large optical split ratio makes the GPON network All-optical hotel with "one line and one terminal for each room"
highly scalable, meeting the hotel's future requirements. One ONT (HG8247) is deployed in each hotel room and
The LAN and WLAN of a villa can be covered by the same provides voice, broadband, and video services, eliminating the
GPON network. The office area is covered by PON+LAN, and need for deploying multiple systems. CATV service is provisioned
public area is covered by PON+WLAN. In addition, GPON also by RF port, broadband access by FE port, and room telephone
carries hotel services such as video surveillance, bulletins, and service by POTS port. The services of each hotel room are
POS machine service. In this way, all services are carried by the carried over a single fiber in an all-IP manner, simplifying the
same GPON network. network structure and reducing the maintenance costs.
Equipment room
Core switch
Hotel servers
NMS
Surveillance
center OLT
Outdoor FDT
2:32 optical splitter
ONT ONU
Telephone Guest room control TV Wi-Fi Surveillance Bulletins Analog telephone POS machine
Integrated: "As the hotel chooses Huawei's E2E integrated solution, we no longer need to piece things up."
Complete: "The provider's staff have been keeping track of things from the initial phase through the delivery phase of the project.
Their service really impresses me."
Perfect: "So far all the systems are running stably and provide indispensable support for the hotel's business operating. I would call
the solution as perfect."
Smart Grids
A smart grid is built on integrated high-speed bidirectional communications networks. A series of technologies are
employed, such as the advanced sensor and measurement technologies, control methods, as well as decision-making
support systems, so as to build a reliable, secure, economical, efficient, environment-friendly, and safe grid. As a
critical part of a smart grid, automated power distribution is currently the key point of smart grid construction.
0% 100%
High reliability: The SCADA system requires the network to be protected with comprehensive backup mechanisms and
excellent quick recovery resilience.
Tight security: Communications terminals, when deployed outdoors, must be able to resist viruses and malicious attacks.
Environmental adaptiveness: Outdoor operating environments are harsh, so the devices must support excellent anti-
interference and EMC performance, and must be able to run steadily in harsh environments.
Maintainability and manageability: The grid involves a large number of nodes that are widely distributed. The monitoring
system must be capable of remote monitoring, and quick problem locating and handling.
Based on three scenarios of smart grids: automated power distribution, power consumption information collection, and OPLC to
the home, Huawei provides the optimal PON-based product combinations and solutions.
MSTP/IP
Substation Substation
ONU ONT
ONU ONU
RS485
FE
Power distribution automation Centralized electricity meter data collection Broadband access
In the PON-based power distribution system, OLTs are deployed at substations to aggregate data collected by the ONUs from
subordinate terminals, such as the switch stations and ring main units. Meanwhile, the ONUs can be deployed close to user
residences for collecting the power consumption information from electricity meters, in this way implementing centralized remote
meter data collection. In addition, fibers are routed to user households so that the fibers can carry broadband and television services.
Solution Highlights
No.1 Industrial-grade power grid ONU
Supports a wide range of temperatures: -40C to +85C; provides 6 kV lightning protection; entire closure made of aluminum,
well sealed to resist dust and erosion, and features high EMC.
Smart AX MA5621 The industry's first industrial-grade MDU for power grids
Power Grid Dedicated ONU Used for remote information collection and transmission of
power systems
Addresses requirements for video surveillance, wireless
coverage, and campus broadband construction
MA5621 MA5621A
Product Highlights
Wide voltage range: 9 V DC to 60 V DC auto adaptation; or 90 V AC to 290 V AC auto adaptation.
Wide temperature range: -40C to +85C, weathering extreme cold and hot temperatures.
Excellent lightning protection: The power port and Ethernet ports of the ONU support a 6 kV lightning protection capability.
Auto adaptation between 3 modes: supports EPON/GPON/GE; pluggable SFPs.
High reliability: hand-in-hand cold backup and hot backup; zero service interruption with fault-triggered switchover in hot
backup.
Easy OAM: supports the dying gasp; reports power outage alarms within milliseconds, and locates the fault within seconds;
deployed in one-stop manner; supports plug-and-play; supports automatic configuration issuance, requiring no onsite
commissioning; supports remote monitoring and maintenance.
Network-side Interface 2SFP; GPON/GE auto adaptation 1SFP; GPON auto adaptation 1SFP; GPON
Heat Dissipation Mode Natural heat dissipation, without fans Natural heat dissipation, without fans Natural heat dissipation, without fans
Voltage Range DC: 9 V to 60 V AC: 90 V to 290 V AC: 90 V to 290 V AC: 100 V to 240 V
Qingdao's downtown areas, especially economically Against such a backdrop, Qingdao Power Supply Company
developed areas such as CBDs, are crowded with financial starts the power distribution automation reform trial, to
and IT enterprises as well as hospitals. The businesses of implement automated power distribution for CBD and
such organizations have specialized characteristics, such as residential areas that have important power supply and stable
continuity and zero tolerance to interruption. Therefore, these power grid structure. The first two phases of power distribution
organizations have stringent requirements on the power supply automation include most areas in the south and north parts of
quality, reliability, and power outage duration. the city, covering a total of 19 substations and 104 10 kV lines.
Switch
OLT OLT
User 1
ONU ONU ONU ONU ONU
Concentrator
Benefits for Customer mismatch between the designed load capacity and actual load
capacity of some lines.
The voltage pass rate increases from 99.5% to over 99.9%.
Through the automated power distribution network, the The 10 kV reliability increases from 99.96% to over 99.99%,
company is able to monitor the load status of power distribution reducing power loss by over 33.41 million kWH on average
terminals and lines in real time, thereby effectively adjusting yearly.
power energy allocation, smoothing voltage fluctuations, and The device fault rate decreases. Meanwhile, the distribution
improving voltage pass rate. automation system can monitor the device status and switch
opened/closed status of each power distribution terminal in a
The line loss decreases from 7.5% to below 5.3%. real-time and visualized manner. When a power outage occurs,
The company is able to monitor the entire power distribution maintenance personnel can remotely locate the fault quickly, and
network in real time through the distribution automation remotely operate the power distribution switch by using the "remote
system. Meanwhile, the distribution automation system can control" function, in this way reducing the time for checking
monitor and analyze the load of lines, effectively solving the and fixing lines, and shortening the power outage duration.
Multi-screen interaction
Basic interaction
Unidirectional broadcast
Based on the new requirements of the B&T bidirectional network optimization, Huawei proposes the innovative D-CMTS solution,
which downsizes CMTS devices, and deploys the devices in residential communities or buildings, delivering 1000 Mbit/s to
the building and 100 Mbit/s to the user. The CMTS device carries integrated services, including data, voice, and video services,
implementing the all-scenario solution for MSOs.
Phone
CATV Combiner
PC
Home
EQAM
TX RX
Video STB
CM
TV
Enterprise
ODN
Voice
CM LSW
coverage
OLT
Hotspot
D- CMTS
Data MA5633
CM AP
EMS
Branch equipment room Optical node HFC
The D-CMTS solution moves the physical-layer and data link-layer interfaces from the branch equipment room down to the optical
site. The optical node connects downstream to the HFC network through RF interfaces, and connects upstream to the OLT through
PON ports. Such a network mode can deliver 1000 Mbit/s to the building and 100 Mbit/s to the user, supports traditional services
such as home access, and supports new services such as enterprise L2VPN access and hotspot coverage. It is an all-scenario solution
for MSOs.
Solution Highlights
No.1 Compatible with existing networks
Compatible with the existing OSS and service provisioning modes; compatible with the existing DOCSIS 2.0/3.0 terminals
(including CMs and STBs).
MA5633
Product Highlights
Ultra-broadband coverage: 160 Mbit/s upstream and 800 Mbit/s downstream; supports 256 broadband users.
Environmentally adaptive: IP65 protection rating compliance; wide temperature range: -40C to +55C; suitable for mounting in
outdoor cabinets, in corridors, onto cables, and on walls; supports 60 V remote power supply/220 V mains supply.
Flexible interfaces: supports 3 upstream modes, GPON/EPON/GE; supports 4 RF in/4 RF out and 2 RF in/2 RF out.
Built-in optical receivers/transmitters: Deploying new optical nodes or optical-splitting optical nodes does not require dedicated
optical receivers/transmitters, simplifying engineering and saving space.
Built-in power amplifier: a unique design in the industry, compensating for node loss, and ensuring zero modifications to the
HFC network.
Power Supply 220 V AC; 60 V AC provided along with the mounting cable
EMC CLASS B
Protection
IP65
Rating Internal view of the MA5633
Power
39 W (without the power amplifier), 93 W (with the power amplifier)
Consumption
In big C mode, a device is connected to a large number of MA5633 has built-in power amplifiers, ensuring zero modification
users, sometimes as many as tens of thousands of users. A fault to the HFC network. Moreover, MA5633 is compatible with the
easily paralyzes a large area of the network. With the D-CMTS DOCSIS 2.0/3.0 CMs in the existing network, so users need not
solution, CMTS devices are deployed at the position of optical replace their CMs, realizing fast service provisioning. MA5633
node. A single device is connected to several hundred users. can be interconnected to the existing OSS to implement alarm
Thus, the impact scope of faults is effectively narrowed down. functions.
CMTS
Tx
Head office
Transport
IP network
network
US:4CH/DS:16CH
256HP GPON 1:4
IP STB
CM MA5633 MA5603T
PC OLT Optical
Rx
amplifier
Home FN
Video Surveillance
As an organic combination of vision and network, video surveillance conveys critical information about people's
everyday life in an intuitive and real-time manner. Video surveillance provides important reference for people to
take corresponding measures. Integrated intelligent video surveillance has become the major requirement of public
security. To implement network-based, intelligent, and HD video surveillance, increasingly higher requirements are
posed on the network carrying capabilities.
Network- IP-based
Analog Digital based intelligent
surveillance surveillance surveillance surveillance
Based on the specialized requirements of various industries and scenarios on video surveillance, Huawei provides the GPON
backhaul solution, which applies to all industries and multiple scenarios, and features high bandwidth and wide coverage. The
solution leverages GPON's characteristics, such as flexible network topologies and flexible indoor/outdoor deployment, and offers a
new type of channel that is efficient, secure, and eco-friendly for security surveillance.
ONU
Crosspoint Switehers
Campus IP camera
The GPON ONU collects data from the surveillance cameras. After undergoing optical channel aggregation of the optical splitter
and service aggregation of the OLT, the data is sent to the management platform and surveillance center in the intranet. The
flexible optical split ratios and long-reach coverage of GPON are well aligned with the various deployment requirements of video
surveillance.
Solution Highlights
No.1 High bandwidth
Video streams are transmitted in real time to the cloud through PON.
Access bandwidth requirements are satisfied: 1.25 Gbit/s upstream, 19.5 Mbit/s downstream after 1:32 optical splitting.
Network-side Interface 1GPON, SC/UPC 2SFP; GPON 1*SFP optical module GPON/GE
8/16/24FE
8/16/24FE (POE) Type1: 2 GE (PoE not supported)
User-side Interface 4GE
4GE+4FE (POE) Type2: 2 GE (PoE supported)
8FE (AC, reverse POE)
Temperature Range -40C to +55C -40C to +65C; startup at -25C -40C to +55C
Power port: 6 kV
Protection Capability LAN port: 6 kV LAN port: 6 kV
Service port: 4 kV
Voltage Range AC: 220 V/110 V AC: 220 V/110 V AC: 220 V/110 V
24 ports: 1.92 kg
Weight 0.5 kg 16 ports: 1.91 kg 3.7kg
8 ports: 1.15 kg
Solution
PON access solution is adopted for the road surveillance access network; LAN access solution is adopted for boarding gate surveillance.
All sub-control centers and the main control center are connected to the core switch of the video surveillance network through switches.
The video surveillance network adopts the standard 3-layer architecture, which has clear layering and is easy to maintain.
Storage Server
Main control center
Airbridge sub-control center
OLT
Optical splitter
Video encoder Video encoder
ONU
uniSite Cabinet
Fle
en
xib
F3
Fri
le
philosophy
Faster
China's first small C mass commercial Small C strategic partner with Nanjing
application for Shenzhen Topway Broadcast & Television Group
Integrated networking with big C MA5632 applied in Haian County, Jiangsu
and small C for Guangzhou Digital MA5631 applied in Mongolia
Media TRUE, Thailand
Broadcast & Television
Multi-network converged intelligent access solution for the Safe City Project of Liupanshui City
High-reliability security system for the Financial Street, Beijing
Video surveillance solution for Shanghai Public Security Bureau
Video Surveillance
ODF
iODF-3101 ODF-2101 ODF2109 ODF-R/RA
FDT
iFDT3101D FDT2103D FDT2101D FDT2102D
FAT
iFAT3101TD FAT2110T FAT3201 FAT3204D
Inside
building
cabling ATB3101 ATB3102 CTB2101 GLH-146
Optical
components
SPL9101 SPL9103 Adapter Patch cord
Cable
closures
SSC221X/2131 SSC2231 Drop cable
Trademark Notice
, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.
Other trademarks, product, service and company names mentioned are the property of their respective owners.
The information in this document may contain predictive statements including, Huawei Industrial Base
without limitation, statements regarding the future financial and operating results, Bantian Longgang
future product portfolio, new technology, etc. There are a number of factors Shenzhen 518129, P.R. China
that could cause actual results and developments to differ materially from those Tel: +86-755-28780808
expressed or implied in the predictive statements. Therefore, such information Version No.: M3-032102-20140821-C-2.0
is provided for reference purpose only and constitutes neither an offer nor an
acceptance. Huawei may change the information at any time without notice. www.huawei.com