Вы находитесь на странице: 1из 2

GROUP 4 POWER BOOST SYSTEM (CLUSTER TYPE 1)

Main control valve

Option Bucket

Arm
Arm 1
regeneration
Boom 2
Swing priority Arm 2

Swing Boom 1

Travel(RH) Travel(LH)

Main relief
valve

P1 P2
pressure pressure

Power boost
solenoid valve
Engine

Fuel injection Pilot pump


pump Main pump
Power boost Pump power
button Accel
actuator P M shift EPPR

LH control
lever Signal

Power max button signal Drive signal

MCU Pressure signal

Accel dial signal CN-16A CN-16

Normal

CN-16B
Emergency

Power mode sw signal


Accel dial
Power max
pilot lamp

Cluster
2209S5MS07

When the power boost switch on the left control lever knob is pushed ON, the power mode is set P
mode and maximum digging power is increased by 10 %.
When the power boost function is activated, the power boost solenoid valve pilot pressure raises the
set pressure of the main relief valve to increase the digging power.
Description Condition Function
- Power mode : P
- Accel dial power : 9
Power boost switch : ON
Activated - Power boost solenoid : ON
Accel dial : over 8
- Power boost pilot lmap : ON
- Operating time : max 8 seconds
- Pre-set power mode
Canceled Power boost switch : OFF - Power boost solenoid : OFF
- Power boost pilot lamp : OFF
When the auto power boost is set to Enable and power mode is set to P mode on the cluster, the
digging power is automatically increased as working conditions by the MCU. It is operated max 8
seconds.

5-12
POWER BOOST SYSTEM (CLUSTER TYPE 2)

Main control valve

Option Bucket

Arm
Arm 1
regeneration
Boom 2
Swing priority Arm 2

Swing Boom 1

Travel(RH) Travel(LH)

Main relief
valve

P1 P2
pressure pressure

Power boost
solenoid valve
Engine

Fuel injection Pilot pump


pump Engine speed Main pump
sensor
Power boost Pump power
button Accel
actuator P M shift EPPR

LH control Engine speed sensor signal


lever
Signal
Power max button signal
Drive signal
MCU
Pressure signal
Power mode switch signal
Accel dial signal CN-16A CN-16

Normal

Cluster CN-16B
Emergency

Accel dial

2209S5MS57

When the power boost switch on the left control lever knob is pushed ON, the maximum digging
power is increased by 10 %.
When the power set is at M, H or S and the power boost function is activated, the power boost
solenoid valve pilot pressure raises the set pressure of the main relief valve to increase the digging
power.
Power boost switch
Description
OFF ON
H or S H
Power set
M M
2
Main relief valve set pressure 350 kgf/cm 380 kgf/cm2
Even when pressed continuously,
Time of operation -
it is canceled after 8 sec.
Default - Power boost solenoid valve : OFF

5-13