Вы находитесь на странице: 1из 376

Prepared by: Draka Offshore Catalog 2009

Date: 15 Jul 2009


CONTENTS

Bostmarine Type LSX Power Cable Four Conductor .............................................................................................


1

Bostmarine Type LSX Power Cable Multi-Conductor ............................................................................................


3

Bostmarine Type LSX Power Cable Three Conductor ...........................................................................................


5

Bostmarine Type LSX Power Cable Two Conductor .............................................................................................


7

Bostmarine Type LSX Signal Cable 16 AWG ........................................................................................................


9

Bostmarine Type LSX Signal Cable 18 AWG ........................................................................................................


11

Bostmarine Type LSX Signal Cable 20 AWG ........................................................................................................


13

Bostmarine Type T/N Control Cable Multi-Conductor ............................................................................................


15

Bostmarine Type T/N Control Cable Multi-Conductor Shielded .............................................................................


17

Bostmarine Type T/N Control Cable Shielded Triads ............................................................................................


19

Bostmarine Type T/N Power Cable Four Conductor ..............................................................................................


21

Bostmarine Type T/N Power Cable Three Conductor ............................................................................................


23

Bostmarine Type T/N Power Cable Two Conductor ..............................................................................................


25

Bostmarine Type T/N Signal Cable 14 AWG .........................................................................................................


27

Bostmarine Type T/N Signal Cable 16 AWG .........................................................................................................


29

Bostmarine Type T/N Signal Cable 18 AWG .........................................................................................................


31

Bostmarine Type T/N Signal Cable 20 AWG .........................................................................................................


33

Bostmarine Type X Control Cable ..........................................................................................................................


35

Bostmarine Type X Power Cable Four Conductor .................................................................................................


37

Bostmarine Type X Power Cable Three Conductor ...............................................................................................


39

Bostmarine Type X Power Cable Two Conductor ..................................................................................................


41

Bostmarine Type X Signal Cable 16 AWG .............................................................................................................


43

Bostmarine Type X Signal Cable 18 AWG .............................................................................................................


45

Bostmarine Type X Signal Cable 20 AWG .............................................................................................................


47

Bostrig 125 Type P Control 10&12AWG ................................................................................................................


49

Bostrig 125 Type P Control 12&10AWG ................................................................................................................


51

Bostrig 125 Type P Control 14AWG ......................................................................................................................


53

Bostrig 125 Type P Control 14AWG AS .................................................................................................................


55

Bostrig 125 Type P Control 16AWG ......................................................................................................................


57

II
CONTENTS

Bostrig 125 Type P Control 16AWG AS .................................................................................................................


59

Bostrig 125 Type P Control 18AWG ......................................................................................................................


61

Bostrig 125 Type P Control 18AWG AS .................................................................................................................


63

Bostrig 125 Type P MR Power Cable ....................................................................................................................


65

Bostrig 125 Type P Power 1C ............................................................................................................................


67

Bostrig 125 Type P Power 1C AS ..........................................................................................................................


69

Bostrig 125 Type P Power 2C ............................................................................................................................


71

Bostrig 125 Type P Power 2C AS ..........................................................................................................................


73

Bostrig 125 Type P Power 3C ............................................................................................................................


75

Bostrig 125 Type P Power 3C AS ..........................................................................................................................


77

Bostrig 125 Type P Power 4C ............................................................................................................................


79

Bostrig 125 Type P Power 4C AS ..........................................................................................................................


81

Bostrig 125 Type P Power 5C ............................................................................................................................


83

Bostrig 125 Type P Power 5C AS ..........................................................................................................................


85

Bostrig 125 Type P Signal Cable ...........................................................................................................................


87

Bostrig 125 Type P Signal Cable ...........................................................................................................................


89

Bostrig 125 Type P Signal IO P 16&14AWG .........................................................................................................


91

Bostrig 125 Type P Signal IO P 16&14AWG AS ....................................................................................................


93

Bostrig 125 Type P Signal IO P 20&18AWG .........................................................................................................


95

Bostrig 125 Type P Signal IO P 20&18AWG AS ....................................................................................................


97

Bostrig 125 Type P Signal IO T 18&16AWG ..........................................................................................................


99

Bostrig 125 Type P Signal IO T 18&16AWG AS ....................................................................................................


101

Bostrig 125 Type P VFD 2kV ............................................................................................................................


103

Bostrig MHV-15 Cable IEC 12/20 kV .....................................................................................................................


105

Bostrig MHV-15 Cable IEC 8.7/15 kV ....................................................................................................................


106

Bostrig MHV-15B Cable 100% Level .....................................................................................................................


107

Bostrig MHV-15B Cable 133% Level .....................................................................................................................


108

Bostrig MHV-15BS Cable IEC 12/20 kV ................................................................................................................


109

Bostrig MHV-15BS Cable IEC 8.7/15 kV ...............................................................................................................


110

III
CONTENTS

Bostrig MHV-5 Cable ............................................................................................................................


111

Bostrig MHV-5B Cable ............................................................................................................................


112

Bostrig MHV-5BS Cable ............................................................................................................................


113

Bostrig MHV-8 Cable IEC 3.6/6 kV ........................................................................................................................


114

Bostrig MHV-8 Cable IEC 6/10 kV .........................................................................................................................


115

Bostrig MHV-8B Cable 100% Level .......................................................................................................................


116

Bostrig MHV-8B Cable 133% Level .......................................................................................................................


117

Bostrig MHV-8BS Cable IEC 3.6/6 kV ...................................................................................................................


118

Bostrig MHV-8BS Cable IEC 6/10 kV ....................................................................................................................


119

Bostrig MHV3-15 Cable IEC 12/20 kV ...................................................................................................................


120

Bostrig MHV3-15 Cable IEC 8.7/15 kV ..................................................................................................................


121

Bostrig MHV3-15B Cable 100% Level ...................................................................................................................


122

Bostrig MHV3-15B Cable 133% Level ...................................................................................................................


123

Bostrig MHV3-15BS Cable IEC 12/20 kV ..............................................................................................................


124

Bostrig MHV3-15BS Cable IEC 8.7/15 kV .............................................................................................................


125

Bostrig MHV3-5 Cable ............................................................................................................................


126

Bostrig MHV3-5B Cable ............................................................................................................................


127

Bostrig MHV3-5BS Cable ............................................................................................................................


128

Bostrig MHV3-8 Cable IEC 3.6/6 kV ......................................................................................................................


129

Bostrig MHV3-8 Cable IEC 6/10 kV .......................................................................................................................


130

Bostrig MHV3-8B Cable 100% Level .....................................................................................................................


131

Bostrig MHV3-8B Cable 133% Level .....................................................................................................................


132

Bostrig MHV3-8BS Cable IEC 3.6/6 kV .................................................................................................................


133

Bostrig MHV3-8BS Cable IEC 6/10 kV ..................................................................................................................


134

Bostrig S611T Marine Fiber Optic Cables ..............................................................................................................


135

Bostrig S670 T Marine Fiber Optic Cables .............................................................................................................


137

Datacomm 50 Coaxial cable - 2.7/7.3AF Low Loss FRNC-C ...........................................................................


139

Datacomm 50 Coaxial cable - RG 213 FRNC-B ................................................................................................


141

Datacomm 50 Coaxial cable - RG 214 FRNC-B ................................................................................................


143

IV
CONTENTS

Datacomm 50 Coaxial cable - RG 214 PVC ......................................................................................................


145

Datacomm 50 Coaxial cable - RG 223 FRNC-B ................................................................................................


147

Datacomm 50 Coaxial cable - RG 223 PVC ......................................................................................................


149

Datacomm 6 FOILS 4x2x0.57 (AWG 23) MULTIMEDIA LSHF-FR .......................................................................


151

Datacomm 75 CATV cable - 1.0/4.8 AF FRNC-C ..............................................................................................


153

Datacomm 75 CATV cable - 1.6/7.3 AF FRNC ..................................................................................................


155

Datacomm 75 CATV cable - Coax10 AD 10S FRNC-C .....................................................................................


157

Datacomm Analogue Audio Cable 110 O AC10 SS 26/7 10P ...............................................................................


159

Datacomm Armoured industrial cable AICI-I/O/RM-W ...........................................................................................


161

Datacomm Cat. 5e SF/UTP 4x2x0.51 (AWG 24) FRNC-C ....................................................................................


163

Datacomm Cat. 7 S/FTP 4x2x0.42 (AWG 27/7) Patch LSHF ................................................................................


165

Datacomm Cat. 7 S/FTP 4x2x0.56 (AWG 23) LSHF .............................................................................................


167

Datacomm Optical Fire Resistant Cable QFCI-I/O/RM/C-JM ................................................................................


169

Datacomm S611T Marine Fiber Optic Cable .........................................................................................................


171

Datacomm S670T Armoured Marine Fiber Optic Cable ........................................................................................


173

Datacomm SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 100V ..............................................................................


175

Datacomm ToughCat S/STP 4x2x0,6 (AWG 24/7) LSHF-FR ............................................................................


177

HXXM CL2 1KV ............................................................................................................................


179

HXXM CL5 1KV ............................................................................................................................


181

HXXM FR CL2 1KV ............................................................................................................................


183

HXXM FR CL5 1KV ............................................................................................................................


184

HXXM FR Power & Control ............................................................................................................................


186

HXXM(i) 1kV ............................................................................................................................


188

HXXM(i) 250V ............................................................................................................................


190

HXXMB 1KV CL5 armoured ............................................................................................................................


192

HXXMB FR CL2 1KV armoured ............................................................................................................................


194

HXXMB FR CL5 1KV armoured ............................................................................................................................


196

HXXMB(c) FR 1KV armoured ............................................................................................................................


198

HXXMB(i) 1kV armoured ............................................................................................................................


200

V
CONTENTS

HXXMB(i) 250V armoured ............................................................................................................................


202

HXXMB(i) FR 1kV armoured ............................................................................................................................


204

HXXMB(i) FR 250V armoured ............................................................................................................................


206

BFOU 1kV ............................................................................................................................


208

BFOU(c) 250V ............................................................................................................................


220

BFOU(i) 250V ............................................................................................................................


224

BFOU-HCF(c) 250V ............................................................................................................................


229

BFOU-HCF(i) 250V ............................................................................................................................


231

BFOU-HCF-1kv-HF ............................................................................................................................
233

BU 1kV ............................................................................................................................
238

BU(c) 250V ............................................................................................................................


242

BU(i) 250V ............................................................................................................................


245

RFOU 12 20 24kV ............................................................................................................................


248

RFOU 1kV ............................................................................................................................


251

RFOU 6 10 12kV ............................................................................................................................


263

RFOU(c) 250V ............................................................................................................................


267

RFOU(i) 250V ............................................................................................................................


271

RFOU-HCF-6_10_12kV-HF ............................................................................................................................
276

RU 1kV ............................................................................................................................
279

RU(c) 250V ............................................................................................................................


285

RU(i) 250V ............................................................................................................................


288

UX 1000V ............................................................................................................................
291

Shipline BI 1KV ............................................................................................................................


293

Shipline BXOI 1KV ............................................................................................................................


296

Shipline BXOI 250V ............................................................................................................................


300

Shipline TFOI 12KV ............................................................................................................................


303

Shipline TI 1KV ............................................................................................................................


305

Shipline TI(c) 1KV ............................................................................................................................


311

Shipline TXOI 1KV ............................................................................................................................


314

VI
CONTENTS

Shipline TXOI 250V ............................................................................................................................


320

Shipline Plus TFXI 1KV ............................................................................................................................


323

Shipline Plus TIOI(c) 250V armoured ....................................................................................................................


329

Shipline TFOI 10KV amoured ............................................................................................................................


332

Shipline TIOI 1KV armoured ............................................................................................................................


334

BFCU 1kV ............................................................................................................................


340

BFCU(c) 250V ............................................................................................................................


344

BFCU(i) 250V ............................................................................................................................


348

RFCU 1kV ............................................................................................................................


353

RFCU(c) 250V ............................................................................................................................


357

RFCU(i) 250V ............................................................................................................................


361

RU 1kV ............................................................................................................................
365

RU 1kV earthing cable ............................................................................................................................


367

This catalog represents only a partial selection of Draka Marine, Oil & Gas International wire and
cable products, based on criteria submitted when requesting the information. For a complete list
of Draka Marine, Oil & Gas International products, including specialty conversion and termination
items, visit www.DrakaMOG.com.

All products are subject to current availability. Please check with your Draka Marine, Oil & Gas
International representative.

All contents 2007 Draka Marine, Oil & Gas International. All rights reserved.

VII
Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX POWER CABLE


four conductor / LSZH / unarmored & armored
14 AWG to 500 MCM / 600V

APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600 1
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION 2

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting 3
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-502
DRAKA MOG BOSTMARINE

DUSA_LSX05_1005

CustRef LSX-05
1
BOSTMARINE TYPE LSX POWER CABLE
four conductor / LSZH / unarmored
14 AWG to 500 MCM / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Size Type in mm in mm in mm Lbs/mft Kg/km
FLSXTPO-4 036338 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.440 11.2 120 179
FLSXTPO-6 036339 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.485 12.3 164 244
FLSXTPO-10 036340 10 5.3 7/38.5 0.030 0.76 0.060 1.52 0.575 14.6 241 359
FLSXTPO-16 036341 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.730 18.5 382 568
FLSXTPO-26 036342 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.830 21.1 542 806
FLSXTPO-41 036343 4 21.1 7/77.2 0.045 1.14 0.080 2.03 0.990 25.1 824 1226
FLSXTPO-66 036344 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.140 29.0 1205 1793
FLSXTPO-83 036345 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.290 32.8 1500 2232
FLSXTPO-106 036346 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.390 35.3 1782 2652
FLSXTPO-133 036347 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.500 38.1 2220 3303
FLSXTPO-168 036348 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.625 41.3 2706 4027
FLSXTPO-212 036349 4/0 107.2 19/105.5 0.055 1.40 0.110 2.79 1.830 49.5 3444 5125
FLSXTPO-250 036350 250 127.0 37/82.2 0.065 1.65 0.110 2.79 2.000 50.8 4002 5955
FLSXTPO-300 036351 300 152.0 37/90.0 0.065 1.65 0.110 2.79 2.130 54.1 4680 6964
FLSXTPO-350 036352 350 177.0 37/97.3 0.065 1.65 0.110 2.79 2.260 57.4 5464 8130
FLSXTPO-400 036353 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.370 60.2 6140 9136
FLSXTPO-500 036354 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.580 65.5 7560 11250

four conductor / LSZH / aluminum or bronze armored


14 AWG to 500 MCM / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Size Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
FLSXTPO-4 036338 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.495 12.6 147 219 209 311
FLSXTPO-6 036339 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.540 13.7 193 287 262 390
FLSXTPO-10 036340 10 5.3 7/38.5 0.030 0.76 0.060 1.52 0.630 16.0 276 411 356 530
FLSXTPO-16 036341 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.785 19.9 426 634 526 783
FLSXTPO-26 036342 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.885 22.5 591 879 705 1049
FLSXTPO-41 036343 4 21.1 7/77.2 0.045 1.14 0.080 2.03 1.045 26.5 882 1312 1017 1513
FLSXTPO-66 036344 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.195 30.4 1272 1893 1427 2123
FLSXTPO-83 036345 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.345 34.2 1576 2345 1750 2604
FLSXTPO-106 036346 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.445 36.7 1863 2772 2051 3052
FLSXTPO-133 036347 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.555 39.5 2308 3434 2501 3721
FLSXTPO-168 036348 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.680 42.7 2801 4168 3020 4494
FLSXTPO-212 036349 4/0 107.2 19/105.5 0.055 1.40 0.110 2.79 1.885 47.9 3551 5284 3797 5650
FLSXTPO-250 036350 250 127.0 37/82.2 0.065 1.65 0.110 2.79 2.055 52.2 4118 6128 4387 6528
FLSXTPO-300 036351 300 152.0 37/90.0 0.065 1.65 0.110 2.79 2.185 55.5 4804 7148 5090 7574
FLSXTPO-350 036352 350 177.0 37/97.3 0.065 1.65 0.110 2.79 2.315 58.8 5595 8325 5899 8778
FLSXTPO-400 036353 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.425 61.6 6278 9342 6595 9813
FLSXTPO-500 036354 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.635 66.9 7710 11472 8055 11986

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-06
2
Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX CONTROL CABLE


multi-conductor / LSZH / unarmored & armored
18, 16 and 14 AWG / 600V

APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smOke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized 1
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting 3
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-502
DRAKA MOG BOSTMARINE

DUSA_LSX07_1005

CustRef LSX-07
3
BOSTMARINE TYPE LSX CONTROL CABLE
multi-conductor / LSZH / armored & unarmored
18, 16 and 14 AWG / 600V
18 AWG 1.0 mm2
Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C18LSXTPO-2 036355* 2 7/15.2 0.030 0.76 0.045 1.14 0.32 8.0 47 70 0.375 9.5 67 100 113 168
C18LSXTPO-3 036356* 3 7/15.2 0.030 0.76 0.045 1.14 0.33 8.4 56 83 0.385 9.8 77 115 124 185
C18LSXTPO-4 036357* 4 7/15.2 0.030 0.76 0.045 1.14 0.36 9.1 68 101 0.415 10.5 90 133 142 211
C18LSXTPO-7 036358* 7 7/15.2 0.030 0.76 0.045 1.14 0.42 10.8 99 147 0.475 12.1 125 186 184 274
C18LSXTPO-10 036359* 10 7/15.2 0.030 0.76 0.060 1.52 0.56 14.4 153 228 0.615 15.6 187 279 265 394
C18LSXTPO-14 036360* 14 7/15.2 0.030 0.76 0.060 1.52 0.61 15.5 195 290 0.665 16.9 232 345 316 470
C18LSXTPO-19 036361* 19 7/15.2 0.030 0.76 0.060 1.52 0.67 17.0 250 372 0.725 18.4 290 432 383 570
C18LSXTPO-24 036362* 24 7/15.2 0.030 0.76 0.080 2.03 0.78 19.8 308 458 0.835 21.2 354 527 462 687
C18LSXTPO-30 036363* 30 7/15.2 0.030 0.76 0.080 2.03 0.88 22.4 370 551 0.935 23.7 422 628 543 808
C18LSXTPO-37 036364* 37 7/15.2 0.030 0.76 0.080 2.03 0.93 23.6 480 714 0.985 25.0 535 796 662 985
C18LSXTPO-44 036365* 44 7/15.2 0.030 0.76 0.080 2.03 1.03 26.2 547 814 1.085 27.6 608 905 748 1113
C18LSXTPO-61 036366* 61 7/15.2 0.030 0.76 0.080 2.03 1.10 27.9 696 1036 1.155 29.3 761 1132 910 1354

16 AWG 1.3 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C16LSXTPO-2 036367* 2 7/19.2 0.030 0.76 0.045 1.14 0.34 8.6 57 85 0.395 10.0 78 116 127 189
C16LSXTPO-3 036368* 3 7/19.2 0.030 0.76 0.045 1.14 0.36 9.1 71 106 0.415 10.5 93 138 145 216
C16LSXTPO-4 036369* 4 7/19.2 0.030 0.76 0.045 1.14 0.39 9.9 87 129 0.445 11.3 111 165 167 248
C16LSXTPO-7 036370* 7 7/19.2 0.030 0.76 0.045 1.14 0.46 11.7 129 192 0.515 13.1 157 234 222 330
C16LSXTPO-10 036371* 10 7/19.2 0.030 0.76 0.060 1.52 0.61 15.6 197 293 0.665 16.9 234 348 318 473
C16LSXTPO-14 036372* 14 7/19.2 0.030 0.76 0.060 1.52 0.67 16.9 255 379 0.725 18.4 295 439 388 577
C16LSXTPO-19 036373* 19 7/19.2 0.030 0.76 0.060 1.52 0.73 18.7 328 488 0.785 19.9 372 553 472 702
C16LSXTPO-24 036374* 24 7/19.2 0.030 0.76 0.080 2.03 0.90 22.9 444 661 0.955 24.5 497 740 620 922
C16LSXTPO-30 036375* 30 7/19.2 0.030 0.76 0.080 2.03 0.95 24.1 529 787 1.055 26.8 585 870 715 1064
C16LSXTPO-37 036376* 37 7/19.2 0.030 0.76 0.080 2.03 1.02 25.9 631 939 1.075 27.3 691 1028 830 1235
C16LSXTPO-44 036377* 44 7/19.2 0.030 0.76 0.080 2.03 1.16 29.3 748 1113 1.215 30.9 816 1214 974 1449
C16LSXTPO-61 036378* 61 7/19.2 0.030 0.76 0.080 2.03 1.27 32.4 980 1458 1.325 33.7 1054 1568 1227 1826

14 AWG 2.1 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C14LSXTPO-2 036379* 2 7/24.2 0.030 0.76 0.045 1.14 0.37 9.4 72 107 0.425 10.8 95 141 148 220
C14LSXTPO-3 036380* 3 7/24.2 0.030 0.76 0.045 1.14 0.39 9.9 92 137 0.445 11.3 116 173 172 256
C14LSXTPO-4 036381* 4 7/24.2 0.030 0.76 0.045 1.14 0.42 10.8 114 170 0.475 12.1 140 208 199 296
C14LSXTPO-7 036382* 7 7/24.2 0.030 0.76 0.045 1.14 0.51 12.8 173 257 0.565 14.3 204 304 275 409
C14LSXTPO-10 036383* 10 7/24.2 0.030 0.76 0.060 1.52 0.68 17.1 261 388 0.735 18.7 302 449 396 589
C14LSXTPO-14 036384* 14 7/24.2 0.030 0.76 0.060 1.52 0.73 18.5 342 509 0.785 19.9 386 574 486 723
C14LSXTPO-19 036385* 19 7/24.2 0.030 0.76 0.060 1.52 0.81 20.6 444 661 0.865 22.0 492 732 603 897
C14LSXTPO-24 036386* 24 7/24.2 0.030 0.76 0.080 2.03 0.99 25.1 593 882 1.045 26.5 651 967 786 1170
C14LSXTPO-30 036387* 30 7/24.2 0.030 0.76 0.080 2.03 1.05 26.7 714 1063 1.105 28.1 776 1155 919 1367
C14LSXTPO-37 036388* 37 7/24.2 0.030 0.76 0.080 2.03 1.13 28.7 856 1274 1.185 30.1 922 1372 1076 1601
C14LSXTPO-44 036389* 44 7/24.2 0.030 0.76 0.080 2.03 1.27 32.3 1010 1503 1.325 33.7 1084 1613 1257 1870
C14LSXTPO-61 036390* 61 7/24.2 0.030 0.76 0.080 2.03 1.40 35.4 1350 2009 1.455 37.0 1432 2130 1621 2412

*NOTE: For aluminum armored versions, add an A (ex. 036379A). For bronze armored versions, add a B (ex. 036079B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-08
4
Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX POWER CABLE


three conductor / LSZH / unarmored & armored
14 AWG to 1000 MCM / 600V

APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600 1
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
2
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting 3
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-502. Thickness as
shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-502
DRAKA MOG BOSTMARINE

DUSA_LSX03_1005

CustRef LSX-03
5
BOSTMARINE TYPE LSX POWER CABLE
three conductor / LSZH / unarmored
14 AWG to 1000 MCM / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Size Type in mm in mm in mm Lbs/mft Kg/km
TLSXTPO-4 036319 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.400 10.2 90 134
TLSXTPO-6 036320 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.440 11.2 120 179
TLSXTPO-10 036321 10 5.3 7/38.5 0.030 0.76 0.045 1.14 0.500 12.7 170 253
TLSXTPO-16 036322 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.670 17.1 280 417
TLSXTPO-26 036323 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.750 19.1 395 588
TLSXTPO-41 036324 4 21.1 7/77.2 0.045 1.14 0.080 2.03 0.900 23.0 570 848
TLSXTPO-66 036325 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.030 26.2 875 1302
TLSXTPO-83 036326 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.160 29.5 1090 1622
TLSXTPO-106 036327 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.255 31.9 1320 1964
TLSXTPO-133 036328 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.355 34.4 1615 2403
TLSXTPO-168 036329 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.470 37.3 1980 2947
TLSXTPO-212 036330 4/0 107.2 19/105.5 0.055 1.40 0.080 2.03 1.595 40.5 2435 3624
TLSXTPO-250 036331 250 127.0 37/82.2 0.065 1.65 0.110 2.79 1.810 46.0 2965 4412
TLSXTPO-300 036332 300 152.0 37/90.0 0.065 1.65 0.110 2.79 1.930 49.0 3485 5186
TLSXTPO-350 036333 350 177.0 37/97.3 0.065 1.65 0.110 2.79 2.040 51.8 4005 5960
TLSXTPO-400 036334 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.140 54.4 4525 6734
TLSXTPO-500 036335 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.330 59.2 5545 8252
TLSXTPO-750 036336 750 380.0 61/110.9 0.080 2.03 0.140 3.56 2.865 72.8 8420 12530
TLSXTPO-1000 036337 1000 507.0 61/128.0 0.080 2.03 0.140 3.56 3.200 81.3 11000 16370

three conductor / LSZH / aluminum and bronze armored


14 AWG to 1000 MCM / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Size Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TLSXTPO-4 036319 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.455 11.3 115 171 171 254
TLSXTPO-6 036320 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.495 12.6 147 219 209 311
TLSXTPO-10 036321 10 5.3 7/38.5 0.030 0.76 0.045 1.14 0.555 14.1 200 298 270 402
TLSXTPO-16 036322 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.725 18.4 320 476 413 615
TLSXTPO-26 036323 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.805 20.4 440 655 543 808
TLSXTPO-41 036324 4 21.1 7/77.2 0.045 1.14 0.080 2.03 0.955 24.3 623 927 746 1110
TLSXTPO-66 036325 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.085 27.6 936 1393 1076 1601
TLSXTPO-83 036326 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.215 30.9 1158 1732 1316 1958
TLSXTPO-106 036327 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.310 33.3 1394 2074 1564 2327
TLSXTPO-133 036328 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.410 35.8 1694 2521 1878 2794
TLSXTPO-168 036329 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.525 38.7 2066 3074 2265 3370
TLSXTPO-212 036330 4/0 107.2 19/105.5 0.055 1.40 0.080 2.03 1.650 41.9 2528 3762 2743 4082
TLSXTPO-250 036331 250 127.0 37/82.2 0.065 1.65 0.110 2.79 1.865 47.4 3070 4568 3314 4931
TLSXTPO-300 036332 300 152.0 37/90.0 0.065 1.65 0.110 2.79 1.985 50.4 3597 5352 3857 5739
TLSXTPO-350 036333 350 177.0 37/97.3 0.065 1.65 0.110 2.79 2.095 53.2 4124 6137 4398 6544
TLSXTPO-400 036334 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.195 55.8 4649 6918 4937 7346
TLSXTPO-500 036335 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.385 60.6 5680 8452 5993 8918
TLSXTPO-750 036336 750 380.0 61/110.9 0.080 2.03 0.140 3.56 2.920 74.2 8586 12776 8969 13346
TLSXTPO-1000 036337 1000 507.0 61/128.0 0.080 2.03 0.140 3.56 3.255 82.7 11185 16643 11613 17280

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-04
6
Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX POWER CABLE


two conductor / LSZH / unarmored & armored
14 AWG to 1000 MCM / 600V

APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600 1
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION 2

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting 3
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-500. Thickness as
shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DRAKA MOG BOSTMARINE

DUSA_LSX01_1005

CustRef LSX-01
7
BOSTMARINE TYPE LSX POWER CABLE
two conductor / LSZH / unarmored
14 AWG to 1000 MCM / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Size Type in mm in mm in mm Lbs/mft Kg/km
DLSXTPO-4 036299 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.380 9.7 81 121
DLSXTPO-6 036300 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.420 10.7 98 146
DLSXTPO-10 036301 10 5.3 7/38.5 0.030 0.76 0.045 1.14 0.470 11.9 138 205
DLSXTPO-16 036302 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.630 16.0 234 348
DLSXTPO-26 036303 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.705 17.9 280 417
DLSXTPO-41 036304 4 21.1 7/77.2 0.045 1.14 0.060 1.52 0.810 20.6 448 667
DLSXTPO-66 036305 2 33.6 7/97.4 0.045 1.14 0.080 2.03 0.970 24.6 682 1015
DLSXTPO-83 036306 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.090 27.7 835 1242
DLSXTPO-106 036307 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.180 30.0 915 1362
DLSXTPO-133 036308 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.270 32.3 1222 1818
DLSXTPO-168 036309 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.380 35.1 1491 2219
DLSXTPO-212 036310 4/0 107.2 19/105.5 0.055 1.40 0.080 2.03 1.490 37.8 1805 2686
DLSXTPO-250 036311 250 127.0 37/82.2 0.065 1.65 0.080 2.03 1.630 41.4 1945 2894
DLSXTPO-300 036312 300 152.0 37/90.0 0.065 1.65 0.110 2.79 1.810 46.0 2385 3549
DLSXTPO-350 036313 350 177.0 37/97.3 0.065 1.65 0.110 2.79 1.910 48.5 2735 4070
DLSXTPO-400 036314 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.005 50.9 3080 4584
DLSXTPO-500 036315 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.180 55.4 3755 5588
DLSXTPO-600 036316 600 304.0 61/99.2 0.080 2.03 0.110 2.79 2.405 61.1 4530 6741
DLSXTPO-750 036317 750 380.0 61/110.9 0.080 2.03 0.110 2.79 2.620 66.5 5550 8259
DLSXTPO-1000 036318 1000 507.0 61/128.0 0.080 2.03 0.110 2.79 2.995 76.1 7390 10997

two conductor / LSZH / aluminum and bronze armored


14 AWG to 1000 MCM / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Size Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
DLSXTPO-4 036299* 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.435 11.0 104 155 159 237
DLSXTPO-6 036300* 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.475 12.1 124 185 183 272
DLSXTPO-10 036301* 10 5.3 7/38.5 0.030 0.76 0.045 1.14 0.525 13.3 167 248 233 347
DLSXTPO-16 036302* 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.685 17.4 272 405 359 534
DLSXTPO-26 036303* 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.760 19.3 322 479 419 623
DLSXTPO-41 036304* 4 21.1 7/77.2 0.045 1.14 0.060 1.52 0.865 22.0 496 738 607 903
DLSXTPO-66 036305* 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.025 26.0 739 1100 872 1298
DLSXTPO-83 036306* 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.145 29.1 899 1338 1047 1558
DLSXTPO-106 036307* 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.235 31.4 984 1464 1145 1704
DLSXTPO-133 036308* 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.325 33.7 1296 1928 1469 2632
DLSXTPO-168 036309* 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.435 36.4 1572 2339 1758 2616
DLSXTPO-212 036310* 4/0 107.2 19/105.5 0.055 1.40 0.080 2.03 1.545 39.2 1892 2815 2093 3114
DLSXTPO-250 036311* 250 127.0 37/82.2 0.065 1.65 0.080 2.03 1.685 42.3 2040 3036 2260 3363
DLSXTPO-300 036312* 300 152.0 37/90.0 0.065 1.65 0.110 2.79 1.865 47.4 2490 3705 2734 4068
DLSXTPO-350 036313* 350 177.0 37/97.3 0.065 1.65 0.110 2.79 1.965 49.9 2846 4235 3103 4617
DLSXTPO-400 036314* 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.060 52.3 3197 4757 3466 5157
DLSXTPO-500 036315* 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.235 56.8 3882 5776 4174 6211
DLSXTPO-600 036316* 600 304.0 61/99.2 0.080 2.03 0.110 2.79 2.460 62.5 4670 6949 4992 7428
DLSXTPO-750 036317* 750 380.0 61/110.9 0.080 2.03 0.110 2.79 2.675 67.9 5702 8485 6053 9007
DLSXTPO-1000 036318* 1000 507.0 61/128.0 0.080 2.03 0.110 2.79 3.055 77.6 7563 11254 7964 11850

*NOTE: For aluminum armored versions, add an A (ex. 036299A). For bronze armored versions, add a B (ex. 036299B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-02
8
Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP / LSZH / unarmored & armored
16 AWG 1.31 mm2 / 600V

APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600 1
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998) 2
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
3
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting 4
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to Draka Cableteq USA Specifying Standard J-512
DRAKA MOG BOSTMARINE

DUSA_LSX13_1005

CustRef LSX-13
9
BOSTMARINE TYPE LSX SIGNAL CABLE
indiv. and overall STP / LSZH / unarmored
16 AWG 1.31 mm2 / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP16(IS)LSXTPO-1 036435 1 7/19.2 0.025 0.64 0.045 1.14 0.32 8.1 56 83
TP16(IS-OS)LSXTPO-2 036436 2 7/19.2 0.025 0.64 0.045 1.14 0.50 12.7 104 155
TP16(IS-OS)LSXTPO-3 036437 3 7/19.2 0.025 0.64 0.060 1.52 0.56 14.2 153 228
TP16(IS-OS)LSXTPO-4 036438 4 7/19.2 0.025 0.64 0.060 1.52 0.61 15.5 190 283
TP16(IS-OS)LSXTPO-5 036439 5 7/19.2 0.025 0.64 0.060 1.52 0.67 17.0 227 338
TP16(IS-OS)LSXTPO-6 036440 6 7/19.2 0.025 0.64 0.060 1.52 0.73 18.5 265 394
TP16(IS-OS)LSXTPO-7 036441 7 7/19.2 0.025 0.64 0.060 1.52 0.73 18.5 295 439
TP16(IS-OS)LSXTPO-8 036442 8 7/19.2 0.025 0.64 0.060 1.52 0.79 20.1 332 494
TP16(IS-OS)LSXTPO-9 036443 9 7/19.2 0.025 0.64 0.080 2.03 0.89 22.6 370 551
TP16(IS-OS)LSXTPO-10 036444 10 7/19.2 0.025 0.64 0.080 2.03 0.97 24.6 449 668
TP16(IS-OS)LSXTPO-11 036445 11 7/19.2 0.025 0.64 0.080 2.03 0.99 25.1 487 724
TP16(IS-OS)LSXTPO-12 036446 12 7/19.2 0.025 0.64 0.080 2.03 0.99 25.1 516 768
TP16(IS-OS)LSXTPO-13 036447 13 7/19.2 0.025 0.64 0.080 2.03 1.04 26.4 555 826
TP16(IS-OS)LSXTPO-14 036448 14 7/19.2 0.025 0.64 0.080 2.03 1.04 26.4 585 870
TP16(IS-OS)LSXTPO-15 036449 15 7/19.2 0.025 0.64 0.080 2.03 1.10 27.9 621 924
TP16(IS-OS)LSXTPO-16 036450 16 7/19.2 0.025 0.64 0.080 2.03 1.10 27.9 654 974
TP16(IS-OS)LSXTPO-17 036451 17 7/19.2 0.025 0.64 0.080 2.03 1.15 29.2 694 1033
TP16(IS-OS)LSXTPO-18 036452 18 7/19.2 0.025 0.64 0.080 2.03 1.15 29.2 724 1078
TP16(IS-OS)LSXTPO-19 036453 19 7/19.2 0.025 0.64 0.080 2.03 1.15 29.2 754 1122
TP16(IS-OS)LSXTPO-20 036454 20 7/19.2 0.025 0.64 0.080 2.03 1.21 30.7 790 1176
TP16(IS-OS)LSXTPO-21 036455 21 7/19.2 0.025 0.64 0.080 2.03 1.21 30.7 824 1226
TP16(IS-OS)LSXTPO-22 036456 22 7/19.2 0.025 0.64 0.080 2.03 1.28 32.5 865 1287

indiv. and overall STP / LSZH / aluminum and bronze armored


16 AWG 1.31 mm2 / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP16(IS)LSXTPO-1 036435* 1 7/19.2 0.025 0.64 0.045 1.14 0.375 9.5 76 113 122 182
TP16(IS-OS)LSXTPO-2 036436* 2 7/19.2 0.025 0.64 0.045 1.14 0.555 14.1 134 199 204 304
TP16(IS-OS)LSXTPO-3 036437* 3 7/19.2 0.025 0.64 0.060 1.52 0.615 15.6 187 278 265 394
TP16(IS-OS)LSXTPO-4 036438* 4 7/19.2 0.025 0.64 0.060 1.52 0.665 16.9 227 338 311 463
TP16(IS-OS)LSXTPO-5 036439* 5 7/19.2 0.025 0.64 0.060 1.52 0.725 18.4 267 397 360 534
TP16(IS-OS)LSXTPO-6 036440* 6 7/19.2 0.025 0.64 0.060 1.52 0.785 19.9 309 460 409 609
TP16(IS-OS)LSXTPO-7 036441* 7 7/19.2 0.025 0.64 0.060 1.52 0.785 19.9 339 504 439 653
TP16(IS-OS)LSXTPO-8 036442* 8 7/19.2 0.025 0.64 0.060 1.52 0.845 21.4 379 564 487 725
TP16(IS-OS)LSXTPO-9 036443* 9 7/19.2 0.025 0.64 0.080 2.03 0.945 24.0 423 629 544 809
TP16(IS-OS)LSXTPO-10 036444* 10 7/19.2 0.025 0.64 0.080 2.03 1.025 26.0 506 753 639 951
TP16(IS-OS)LSXTPO-11 036445* 11 7/19.2 0.025 0.64 0.080 2.03 1.045 26.5 545 811 680 1012
TP16(IS-OS)LSXTPO-12 036446* 12 7/19.2 0.025 0.64 0.080 2.03 1.045 26.5 574 854 709 1055
TP16(IS-OS)LSXTPO-13 036447* 13 7/19.2 0.025 0.64 0.080 2.03 1.095 27.8 616 917 758 1128
TP16(IS-OS)LSXTPO-14 036448* 14 7/19.2 0.025 0.64 0.080 2.03 1.095 27.8 646 961 788 1173
TP16(IS-OS)LSXTPO-15 036449* 15 7/19.2 0.025 0.64 0.080 2.03 1.155 29.3 686 1021 835 1242
TP16(IS-OS)LSXTPO-16 036450* 16 7/19.2 0.025 0.64 0.080 2.03 1.155 29.3 719 1070 868 1292
TP16(IS-OS)LSXTPO-17 036451* 17 7/19.2 0.025 0.64 0.080 2.03 1.205 24.2 762 1134 918 1366
TP16(IS-OS)LSXTPO-18 036452* 18 7/19.2 0.025 0.64 0.080 2.03 1.205 24.2 792 1178 948 1411
TP16(IS-OS)LSXTPO-19 036453* 19 7/19.2 0.025 0.64 0.080 2.03 1.205 24.2 822 1123 978 1455
TP16(IS-OS)LSXTPO-20 036454* 20 7/19.2 0.025 0.64 0.080 2.03 1.265 32.1 861 1281 1025 1525
TP16(IS-OS)LSXTPO-21 036455* 21 7/19.2 0.025 0.64 0.080 2.03 1.265 32.1 895 1332 1059 1576
TP16(IS-OS)LSXTPO-22 036456* 22 7/19.2 0.025 0.64 0.080 2.03 1.335 33.9 940 1399 1113 1656

*NOTE: For aluminum armored versions, add an A (ex. 036435A). For bronze armored versions, add a B (ex. 036435B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-14
10
Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP signal / LSZH / unarmored & armored
18 AWG 0.82 mm2 / 600V

APPLICATIONS
BOSTMARINE Type LSX 600 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600 1
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998) 2
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
3
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting 4
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to BIW Specifying Standard J512
DRAKA MOG BOSTMARINE

DUSA_LSX11_0905

CustRef LSX-11
11
BOSTMARINE TYPE LSX SIGNAL CABLE
indiv. and overall STP signal / LSZH / unarmored
18 AWG 0.82 mm2 / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP18(IS)LSXTPO-1 036413 1 7/15.2 0.025 0.64 0.045 1.14 0.30 7.6 46 68
TP18(IS-OS)LSXTPO-2 036414 2 7/15.2 0.025 0.64 0.045 1.14 0.45 11.4 85 126
TP18(IS-OS)LSXTPO-3 036415 3 7/15.2 0.025 0.64 0.045 1.14 0.48 12.2 109 162
TP18(IS-OS)LSXTPO-4 036416 4 7/15.2 0.025 0.64 0.060 1.52 0.59 15.0 153 228
TP18(IS-OS)LSXTPO-5 036417 5 7/15.2 0.025 0.64 0.060 1.52 0.61 15.5 182 271
TP18(IS-OS)LSXTPO-6 036418 6 7/15.2 0.025 0.64 0.060 1.52 0.66 16.8 211 314
TP18(IS-OS)LSXTPO-7 036419 7 7/15.2 0.025 0.64 0.060 1.52 0.66 16.8 232 346
TP18(IS-OS)LSXTPO-8 036420 8 7/15.2 0.025 0.64 0.060 1.52 0.72 18.3 262 390
TP18(IS-OS)LSXTPO-9 036421 9 7/15.2 0.025 0.64 0.060 1.52 0.78 19.8 290 432
TP18(IS-OS)LSXTPO-10 036422 10 7/15.2 0.025 0.64 0.080 2.03 0.89 22.6 359 534
TP18(IS-OS)LSXTPO-11 036423 11 7/15.2 0.025 0.64 0.080 2.03 0.91 23.1 346 516
TP18(IS-OS)LSXTPO-12 036424 12 7/15.2 0.025 0.64 0.080 2.03 0.91 23.1 368 548
TP18(IS-OS)LSXTPO-13 036425 13 7/15.2 0.025 0.64 0.080 2.03 0.96 24.4 438 652
TP18(IS-OS)LSXTPO-14 036426 14 7/15.2 0.025 0.64 0.080 2.03 0.96 24.4 459 684
TP18(IS-OS)LSXTPO-15 036427 15 7/15.2 0.025 0.64 0.080 2.03 1.01 25.7 490 729
TP18(IS-OS)LSXTPO-16 036428 16 7/15.2 0.025 0.64 0.080 2.03 1.01 25.7 512 762
TP18(IS-OS)LSXTPO-17 036429 17 7/15.2 0.025 0.64 0.080 2.03 1.06 26.9 543 808
TP18(IS-OS)LSXTPO-18 036430 18 7/15.2 0.025 0.64 0.080 2.03 1.06 26.9 565 840
TP18(IS-OS)LSXTPO-19 036431 19 7/15.2 0.025 0.64 0.080 2.03 1.06 26.9 586 872
TP18(IS-OS)LSXTPO-20 036432 20 7/15.2 0.025 0.64 0.080 2.03 1.11 28.2 619 921
TP18(IS-OS)LSXTPO-21 036433 21 7/15.2 0.025 0.64 0.080 2.03 1.11 28.2 639 951
TP18(IS-OS)LSXTPO-22 036434 22 7/15.2 0.025 0.64 0.080 2.03 1.16 29.5 671 998

indiv. and overall STP signal / LSZH / aluminum and bronze armored
18 AWG 0.82 mm2 / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP18(IS)LSXTPO-1 036413* 1 7/15.2 0.025 0.64 0.045 1.14 0.355 9.0 65 97 108 161
TP18(IS-OS)LSXTPO-2 036414* 2 7/15.2 0.025 0.64 0.045 1.14 0.455 11.6 112 167 176 262
TP18(IS-OS)LSXTPO-3 036415* 3 7/15.2 0.025 0.64 0.045 1.14 0.535 13.6 138 205 206 307
TP18(IS-OS)LSXTPO-4 036416* 4 7/15.2 0.025 0.64 0.060 1.52 0.645 16.4 188 280 271 403
TP18(IS-OS)LSXTPO-5 036417* 5 7/15.2 0.025 0.64 0.060 1.52 0.665 16.9 219 326 303 451
TP18(IS-OS)LSXTPO-6 036418* 6 7/15.2 0.025 0.64 0.060 1.52 0.715 18.2 251 373 342 509
TP18(IS-OS)LSXTPO-7 036419* 7 7/15.2 0.025 0.64 0.060 1.52 0.715 18.2 272 405 363 540
TP18(IS-OS)LSXTPO-8 036420* 8 7/15.2 0.025 0.64 0.060 1.52 0.775 19.7 305 454 404 601
TP18(IS-OS)LSXTPO-9 036421* 9 7/15.2 0.025 0.64 0.060 1.52 0.835 21.2 336 500 444 661
TP18(IS-OS)LSXTPO-10 036422* 10 7/15.2 0.025 0.64 0.080 2.03 0.945 24.0 400 595 524 780
TP18(IS-OS)LSXTPO-11 036423* 11 7/15.2 0.025 0.64 0.080 2.03 0.965 24.5 412 613 533 793
TP18(IS-OS)LSXTPO-12 036424* 12 7/15.2 0.025 0.64 0.080 2.03 0.965 24.5 422 628 546 812
TP18(IS-OS)LSXTPO-13 036425* 13 7/15.2 0.025 0.64 0.080 2.03 1.015 25.8 495 737 626 931
TP18(IS-OS)LSXTPO-14 036426* 14 7/15.2 0.025 0.64 0.080 2.03 1.015 25.8 516 768 647 963
TP18(IS-OS)LSXTPO-15 036427* 15 7/15.2 0.025 0.64 0.080 2.03 1.065 27.1 550 818 687 1022
TP18(IS-OS)LSXTPO-16 036428* 16 7/15.2 0.025 0.64 0.080 2.03 1.065 27.1 572 851 709 1055
TP18(IS-OS)LSXTPO-17 036429* 17 7/15.2 0.025 0.64 0.080 2.03 1.115 28.3 605 900 750 1116
TP18(IS-OS)LSXTPO-18 036430* 18 7/15.2 0.025 0.64 0.080 2.03 1.115 28.3 627 933 772 1149
TP18(IS-OS)LSXTPO-19 036431* 19 7/15.2 0.025 0.64 0.080 2.03 1.115 28.3 648 964 793 1180
TP18(IS-OS)LSXTPO-20 036432* 20 7/15.2 0.025 0.64 0.080 2.03 1.165 29.6 684 1018 835 1242
TP18(IS-OS)LSXTPO-21 036433* 21 7/15.2 0.025 0.64 0.080 2.03 1.165 29.6 704 1048 855 1272
TP18(IS-OS)LSXTPO-22 036434* 22 7/15.2 0.025 0.64 0.080 2.03 1.215 30.9 739 1100 897 1335

*NOTE: For aluminum armored versions, add an A (ex. 036391A). For bronze armored versions, add a B (ex. 036391B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-12
12
Draka Marine Shipboard Cables

BOSTMARINE TYPE LSX SIGNAL CABLE


indiv. and overall STP signal / LSZH / unarmored & armored
20 AWG 0.52 mm2 / 300V

APPLICATIONS
BOSTMARINE Type LSX 300 volt cables are suitable for use in commercial marine applica-
tions where low smoke/zero halogen flame retardant cables having excellent physical and
electrical properties are required. The insulation system has a continuous operating tem-
perature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 300 1
volts. Type LSX cables are approved by ABS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998) 2
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
3
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type LSX thermosetting low smoke cross-linked polyethylene meeting 4
specifications IEEE 45 (1998), IEEE-1580 (2001), UL 1309 X90 and J-512. Thickness as
shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic low smoke polyolefin is applied over the cable core (cov-
ered with a polyester separator tape) and complies with Type TPO thermoplastic low
smoke polyolefin as required in IEEE 45 (1998) and UL 1309 Type TPE.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV
American Bureau of Shipping Approval Certificate No. B315003-X.
Manufactured to BIW Specifying Standard J512
DRAKA MOG BOSTMARINE

DUSA_LSX09_1005

CustRef LSX-09
13
BOSTMARINE TYPE LSX SIGNAL CABLE
indiv. and overall STP signal / LSZH / unarmored
20 AWG 0.52 mm2 / 300V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP20(IS)LSXTPO-1 036391 1 7/12.1 0.025 0.64 0.045 1.14 0.28 7.1 36 54
TP20(IS-OS)LSXTPO-2 036392 2 7/12.1 0.025 0.64 0.045 1.14 0.41 10.4 64 95
TP20(IS-OS)LSXTPO-3 036393 3 7/12.1 0.025 0.64 0.045 1.14 0.43 10.9 80 119
TP20(IS-OS)LSXTPO-4 036394 4 7/12.1 0.025 0.64 0.045 1.14 0.48 12.2 97 144
TP20(IS-OS)LSXTPO-5 036395 5 7/12.1 0.025 0.64 0.060 1.52 0.55 14.0 132 196
TP20(IS-OS)LSXTPO-6 036396 6 7/12.1 0.025 0.64 0.060 1.52 0.60 15.2 152 226
TP20(IS-OS)LSXTPO-7 036397 7 7/12.1 0.025 0.64 0.060 1.52 0.60 15.2 164 244
TP20(IS-OS)LSXTPO-8 036398 8 7/12.1 0.025 0.64 0.060 1.52 0.65 16.5 185 275
TP20(IS-OS)LSXTPO-9 036399 9 7/12.1 0.025 0.64 0.060 1.52 0.69 17.5 204 303
TP20(IS-OS)LSXTPO-10 036400 10 7/12.1 0.025 0.64 0.060 1.52 0.75 19.1 226 336
TP20(IS-OS)LSXTPO-11 036401 11 7/12.1 0.025 0.64 0.060 1.52 0.78 19.8 242 360
TP20(IS-OS)LSXTPO-12 036402 12 7/12.1 0.025 0.64 0.060 1.52 0.78 19.8 256 381
TP20(IS-OS)LSXTPO-13 036403 13 7/12.1 0.025 0.64 0.060 1.52 0.82 20.8 275 409
TP20(IS-OS)LSXTPO-14 036404 14 7/12.1 0.025 0.64 0.060 1.52 0.82 20.8 289 430
TP20(IS-OS)LSXTPO-15 036405 15 7/12.1 0.025 0.64 0.080 2.03 0.90 22.9 346 515
TP20(IS-OS)LSXTPO-16 036406 16 7/12.1 0.025 0.64 0.080 2.03 0.90 22.9 359 534
TP20(IS-OS)LSXTPO-17 036407 17 7/12.1 0.025 0.64 0.080 2.03 0.95 24.1 381 566
TP20(IS-OS)LSXTPO-18 036408 18 7/12.1 0.025 0.64 0.080 2.03 0.95 24.1 395 587
TP20(IS-OS)LSXTPO-19 036409 19 7/12.1 0.025 0.64 0.080 2.03 0.95 24.1 408 608
TP20(IS-OS)LSXTPO-20 036410 20 7/12.1 0.025 0.64 0.080 2.03 0.99 25.1 429 638
TP20(IS-OS)LSXTPO-21 036411 21 7/12.1 0.025 0.64 0.080 2.03 0.99 25.1 444 661
TP20(IS-OS)LSXTPO-22 036412 22 7/12.1 0.025 0.64 0.080 2.03 1.04 26.4 466 694

indiv. and overall STP signal / LSZH / aluminum and bronze armored
20 AWG 0.52 mm2 / 300V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP20(IS)LSXTPO-1 036391* 1 7/12.1 0.025 0.64 0.045 1.14 0.335 8.5 54 80 95 141
TP20(IS-OS)LSXTPO-2 036392* 2 7/12.1 0.025 0.64 0.045 1.14 0.465 11.8 89 132 147 219
TP20(IS-OS)LSXTPO-3 036393* 3 7/12.1 0.025 0.64 0.045 1.14 0.485 12.3 106 158 167 248
TP20(IS-OS)LSXTPO-4 036394* 4 7/12.1 0.025 0.64 0.045 1.14 0.535 13.6 126 187 194 289
TP20(IS-OS)LSXTPO-5 036395* 5 7/12.1 0.025 0.64 0.060 1.52 0.605 15.4 165 246 242 360
TP20(IS-OS)LSXTPO-6 036396* 6 7/12.1 0.025 0.64 0.060 1.52 0.655 16.6 188 280 271 403
TP20(IS-OS)LSXTPO-7 036397* 7 7/12.1 0.025 0.64 0.060 1.52 0.655 16.6 200 298 283 421
TP20(IS-OS)LSXTPO-8 036398* 8 7/12.1 0.025 0.64 0.060 1.52 0.705 17.9 224 333 314 467
TP20(IS-OS)LSXTPO-9 036399* 9 7/12.1 0.025 0.64 0.060 1.52 0.745 18.9 245 365 340 506
TP20(IS-OS)LSXTPO-10 036400* 10 7/12.1 0.025 0.64 0.060 1.52 0.805 20.4 271 403 374 556
TP20(IS-OS)LSXTPO-11 036401* 11 7/12.1 0.025 0.64 0.060 1.52 0.835 21.2 288 429 396 589
TP20(IS-OS)LSXTPO-12 036402* 12 7/12.1 0.025 0.64 0.060 1.52 0.835 21.2 302 449 410 610
TP20(IS-OS)LSXTPO-13 036403* 13 7/12.1 0.025 0.64 0.060 1.52 0.875 22.2 324 482 436 649
TP20(IS-OS)LSXTPO-14 036404* 14 7/12.1 0.025 0.64 0.060 1.52 0.875 22.2 338 503 450 670
TP20(IS-OS)LSXTPO-15 036405* 15 7/12.1 0.025 0.64 0.080 2.03 0.955 24.3 399 594 522 777
TP20(IS-OS)LSXTPO-16 036406* 16 7/12.1 0.025 0.64 0.080 2.03 0.955 24.3 412 613 535 796
TP20(IS-OS)LSXTPO-17 036407* 17 7/12.1 0.025 0.64 0.080 2.03 1.005 25.5 437 650 567 844
TP20(IS-OS)LSXTPO-18 036408* 18 7/12.1 0.025 0.64 0.080 2.03 1.005 25.5 451 671 581 869
TP20(IS-OS)LSXTPO-19 036409* 19 7/12.1 0.025 0.64 0.080 2.03 1.005 25.5 464 690 594 884
TP20(IS-OS)LSXTPO-20 036410* 20 7/12.1 0.025 0.64 0.080 2.03 1.045 26.5 487 725 622 926
TP20(IS-OS)LSXTPO-21 036411* 21 7/12.1 0.025 0.64 0.080 2.03 1.045 26.5 502 747 637 948
TP20(IS-OS)LSXTPO-22 036412* 22 7/12.1 0.025 0.64 0.080 2.03 1.095 27.8 527 784 669 995

*NOTE: For aluminum armored versions, add an A (ex. 036391A). For bronze armored versions, add a B (ex. 036391B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef LSX-10
14
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N CONTROL CABLE


multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 3
Insulated conductors are rated VW1.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DRAKA MOG BOSTMARINE

DUSA_TN07_0905

CustRef TN-07
15
BOSTMARINE TYPE T/N CONTROL CABLE
multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V
18 AWG 1.0 mm2
Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C18T/NT-2 036125* 2 7/15.2 0.019 0.48 0.045 1.14 0.28 7.1 35 52 0.33 8.4 53 79 94 140
C18T/NT-3 036126* 3 7/15.2 0.019 0.48 0.045 1.14 0.29 7.4 44 65 0.34 8.6 62 92 105 156
C18T/NT-4 036127* 4 7/15.2 0.019 0.48 0.045 1.14 0.31 7.9 53 79 0.36 9.1 72 107 117 174
C18T/NT-7 029781* 7 7/15.2 0.019 0.48 0.045 1.14 0.36 9.1 86 128 0.41 10.4 108 160 160 238
C18T/NT-10 030630* 10 7/15.2 0.019 0.48 0.060 1.52 0.45 11.4 117 174 0.50 12.7 144 214 208 310
C18T/NT-16 350376 16 7/15.2 0.019 0.48 0.060 1.52 0.57 14.5 210 312 0.63 16.0 244 363 324 482
C18T/NT-20 350377 20 7/15.2 0.019 0.48 0.060 1.52 0.63 16.0 255 379 0.69 17.5 292 434 379 564
C18T/NT-24 036131* 24 7/15.2 0.019 0.48 0.060 1.52 0.65 16.5 262 390 0.70 17.8 301 448 391 582
C18T/NT-30 036132* 30 7/15.2 0.019 0.48 0.060 1.52 0.69 17.5 310 461 0.74 18.8 351 522 446 664
C18T/NT-37 036133* 37 7/15.2 0.019 0.48 0.060 1.52 0.74 18.8 372 554 0.79 20.1 416 619 518 771
C18T/NT-44 036134* 44 7/15.2 0.019 0.48 0.060 1.52 0.86 21.8 471 701 0.91 23.1 522 777 640 952
C18T/NT-61 036135* 61 7/15.2 0.019 0.48 0.080 2.03 0.95 24.1 612 911 1.00 25.4 668 994 798 1187

16 AWG 1.3 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C16T/NT-2 030109* 2 7/19.2 0.019 0.48 0.045 1.14 0.30 7.6 49 73 0.35 8.9 68 101 111 165
C16T/NT-3 036115* 3 7/19.2 0.019 0.48 0.045 1.14 0.31 7.9 53 79 0.36 9.1 72 107 117 174
C16T/NT-4 030131* 4 7/19.2 0.019 0.48 0.045 1.14 0.34 8.6 72 107 0.39 9.9 93 138 142 211
C16T/NT-7 030631* 7 7/19.2 0.019 0.48 0.045 1.14 0.39 9.9 114 170 0.44 11.2 138 205 194 289
C16T/NT-10 030137* 10 7/19.2 0.019 0.48 0.045 1.14 0.50 12.7 159 237 0.55 14.0 189 281 259 385
C16T/NT-16 350097 16 7/19.2 0.019 0.48 0.060 1.52 0.63 16.0 273 406 0.69 17.5 310 461 397 591
C16T/NT-20 350101 20 7/19.2 0.019 0.48 0.060 1.52 0.69 17.5 334 497 0.75 19.1 375 558 470 699
C16T/NT-24 030149* 24 7/19.2 0.019 0.48 0.060 1.52 0.72 18.3 358 533 0.77 19.6 401 597 500 744
C16T/NT-30 030150* 30 7/19.2 0.019 0.48 0.060 1.52 0.77 19.6 431 641 0.82 20.8 477 710 583 868
C16T/NT-37 030132* 37 7/19.2 0.019 0.48 0.080 2.03 0.87 22.1 556 827 0.92 23.4 608 905 727 1082
C16T/NT-44 030180* 44 7/19.2 0.019 0.48 0.080 2.03 0.96 24.4 652 970 1.01 25.7 709 1055 840 1250
C16T/NT-61 036140* 61 7/19.2 0.019 0.48 0.080 2.03 1.07 27.2 816 1214 1.12 28.7 879 1308 1025 1525

14 AWG 2.1 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C14T/NT-2 036141* 2 7/24.2 0.019 0.48 0.045 1.14 0.33 8.4 62 92 0.38 9.7 83 124 130 193
C14T/NT-3 036142* 3 7/24.2 0.019 0.48 0.045 1.14 0.35 8.9 81 121 0.40 10.2 103 153 153 228
C14T/NT-4 036143* 4 7/24.2 0.019 0.48 0.045 1.14 0.37 9.4 101 150 0.42 10.7 124 185 177 263
C14T/NT-7 030129* 7 7/24.2 0.019 0.48 0.045 1.14 0.44 11.2 157 234 0.49 12.4 184 274 246 366
C14T/NT-10 030108* 10 7/24.2 0.019 0.48 0.060 1.52 0.58 14.7 240 357 0.63 16.0 275 409 356 530
C14T/NT-16 350105 16 7/24.2 0.015 / 0.004 0.060 1.52 0.69 17.5 366 545 0.75 19.1 407 606 502 747
C14T/NT-20 350111 20 7/24.2 0.015 / 0.004 0.060 1.52 0.74 18.8 451 671 0.80 20.3 495 737 596 887
C14T/NT-24 030151* 24 7/24.2 0.019 0.48 0.060 1.52 0.81 20.6 494 735 0.86 21.8 542 806 653 972
C14T/NT-30 036147* 30 7/24.2 0.019 0.48 0.080 2.03 0.90 22.9 639 951 0.95 24.1 692 1030 815 1213
C14T/NT-37 030153* 37 7/24.2 0.019 0.48 0.080 2.03 0.96 24.4 762 1134 1.01 25.7 818 1217 950 1414
C14T/NT-44 036148* 44 7/24.2 0.019 0.48 0.080 2.03 1.08 27.4 901 1341 1.13 28.7 965 1436 1112 1655
C14T/NT-61 036149* 61 7/24.2 0.019 0.48 0.080 2.03 1.14 29.0 1210 1801 1.19 30.2 1277 1900 1432 2131

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-08
16
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N CONTROL CABLE


multi-conductor shielded / unarmored & armored
16 and 14 AWG / 600V

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized 1
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998) 2
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION 3
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 4
Insulated conductors are rated VW1.
3. SHIELD
An aluminum/polyester tape with drain wire, 100% coverage, is applied over the
cabled core.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DRAKA MOG BOSTMARINE

DUSA_TN19_0905

CustRef TN-19
17
BOSTMARINE TYPE T/N CONTROL CABLE
multi-conductor shielded / unarmored & armored
16 and 14 AWG / 600V
16 AWG 1.3 mm2
Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C16(OS)T/NT-2 030109* 2 7/19.2 0.019 0.48 0.045 1.14 0.31 7.9 58 86 0.37 9.4 77 115 122 182
C16(OS)T/NT-3 036115* 3 7/19.2 0.019 0.48 0.045 1.14 0.33 8.4 63 94 0.39 9.9 83 124 130 193
C16(OS)T/NT-4 030131* 4 7/19.2 0.019 0.48 0.045 1.14 0.35 8.9 82 122 0.41 10.4 103 153 153 228
C16(OS)T/NT-7 030631* 7 7/19.2 0.019 0.48 0.045 1.14 0.42 10.7 124 185 0.48 12.2 150 305 209 311
C16(OS)T/NT-10 030137* 10 7/19.2 0.019 0.48 0.045 1.14 0.55 14.0 169 251 0.58 14.7 200 418 273 406
C16(OS)T/NT-16 350172* 16 7/19.2 0.019 0.48 0.060 1.52 0.63 16.0 281 418 0.69 17.5 319 475 406 604
C16(OS)T/NT-20 350166* 20 7/19.2 0.019 0.48 0.060 1.52 0.70 17.8 343 510 0.76 19.3 385 573 480 714
C16(OS)T/NT-24 030149* 24 7/19.2 0.019 0.48 0.060 1.52 0.76 19.3 371 552 0.82 20.8 416 619 521 775
C16(OS)T/NT-30 030150* 30 7/19.2 0.019 0.48 0.060 1.52 0.81 20.6 444 661 0.87 22.1 492 1056 602 896
C16(OS)T/NT-37 030132* 37 7/19.2 0.019 0.48 0.080 2.03 0.91 23.1 569 847 0.97 24.6 623 927 747 1112
C16(OS)T/NT-44 030180* 44 7/19.2 0.019 0.48 0.080 2.03 1.03 26.2 666 991 1.09 27.7 727 1082 867 1290
C16(OS)T/NT-61 036140* 61 7/19.2 0.019 0.48 0.080 2.03 1.13 28.7 830 1235 1.19 30.2 896 1333 1049 1561

14 AWG 2.1 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C14(OS)T/NT-2 036141* 2 7/24.2 0.019 0.48 0.045 1.14 0.34 8.6 75 112 0.40 10.2 96 143 145 216
C14(OS)T/NT-3 036142* 3 7/24.2 0.019 0.48 0.045 1.14 0.36 9.1 94 140 0.42 10.7 116 173 167 248
C14(OS)T/NT-4 036143* 4 7/24.2 0.019 0.48 0.045 1.14 0.42 10.7 115 171 0.48 12.2 140 208 219 326
C14(OS)T/NT-7 030129* 7 7/24.2 0.019 0.48 0.045 1.14 0.46 11.6 171 254 0.52 13.2 199 296 273 406
C14(OS)T/NT-10 030108* 10 7/24.2 0.019 0.48 0.060 1.52 0.58 14.7 254 377 0.64 16.3 206 307 369 549
C14(OS)T/NT-16 350374* 16 7/24.2 0.019 0.48 0.060 1.52 0.63 16.0 378 562 0.75 19.1 419 623 514 765
C14(OS)T/NT-20 350375* 20 7/24.2 0.019 0.48 0.060 1.52 0.71 18.0 462 687 0.82 20.8 507 754 612 911
C14(OS)T/NT-24 030151* 24 7/24.2 0.019 0.48 0.060 1.52 0.84 21.3 510 759 0.90 22.9 560 833 675 1004
C14(OS)T/NT-30 036147* 30 7/24.2 0.019 0.48 0.080 2.03 0.93 23.6 655 975 0.99 25.1 710 1056 837 1245
C14(OS)T/NT-37 030153* 37 7/24.2 0.019 0.48 0.080 2.03 1.00 25.4 778 1158 1.06 26.9 837 1245 972 1446
C14(OS)T/NT-44 036148* 44 7/24.2 0.019 0.48 0.080 2.03 1.13 28.7 917 1364 1.19 30.2 983 1463 1137 1692
C14(OS)T/NT-61 036149* 61 7/24.2 0.019 0.48 0.080 2.03 1.18 30.0 1226 1824 1.24 31.5 1295 1927 1456 2167

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-20
18
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N CONTROL CABLE


indiv. & overall shielded triads / unarmored & armored
18, 16 and 14 AWG / 600V
DRAKA-USA

APPLICATIONS ISO9001
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica- QSC3497
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION 2
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION 3
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse.
Insulated conductors are rated VW1.
3. TRIAD SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage 4
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-510
DRAKA MOG BOSTMARINE

DUSA_TN17_1005

CustRef TN-17
19
BOSTMARINE TYPE T/N CONTROL CABLE
indiv. & overall shielded twisted triad / unarmored & armored
18, 16 and 14 AWG / 600V
18 AWG 1.0 mm2
Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* triads Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
TT18(IS-OS)T/NT-1 350370 1 7/15.2 0.019 0.48 0.045 1.14 0.31 7.9 56 83 0.37 9.4 75 112 119 177
TT18(IS-OS)T/NT-3 350371 3 7/15.2 0.019 0.48 0.060 1.52 0.59 15.0 174 259 0.65 16.5 209 311 291 433
TT18(IS-OS)T/NT-6 350372 6 7/15.2 0.019 0.48 0.060 1.52 0.76 19.3 294 437 0.82 20.8 339 504 444 661
TT18(IS-OS)T/NT-12350373 12 7/15.2 0.019 0.48 0.080 2.03 1.05 26.7 567 844 1.11 28.2 629 936 772 1149

16 AWG 1.3 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* triads Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
TT16(IS-OS)T/NT-1 350366 1 7/19.2 0.019 0.48 0.045 1.14 0.33 8.4 70 104 0.39 9.9 91 135 138 205
TT16(IS-OS)T/NT-3 350367 3 7/19.2 0.019 0.48 0.060 1.52 0.64 16.3 222 330 0.70 17.8 260 387 349 519
TT16(IS-OS)T/NT-6 350368 6 7/19.2 0.019 0.48 0.060 1.52 0.84 21.3 380 565 0.90 22.9 430 640 555 826
TT16(IS-OS)T/NT-12350369 12 7/19.2 0.019 0.48 0.080 2.03 1.15 29.2 683 1016 1.21 30.7 751 1117 907 1350

14 AWG 2.1 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* triads Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
TT14(IS-OS)T/NT-1 350362 1 7/24.2 0.019 0.48 0.045 1.14 0.36 9.1 93 138 0.42 10.7 115 171 166 247
TT14(IS-OS)T/NT-3 350363 3 7/24.2 0.019 0.48 0.060 1.52 0.70 17.8 294 437 0.76 19.3 336 500 431 641
TT14(IS-OS)T/NT-6 350364 6 7/24.2 0.019 0.48 0.060 1.52 0.96 24.4 558 830 1.02 25.9 614 914 745 1109
TT14(IS-OS)T/NT-12350365 12 7/24.2 0.019 0.48 0.080 2.03 1.26 32.0 1007 1498 1.32 33.5 1081 1609 1251 1861

*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-18
20
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N POWER CABLE


four conductor power distribution / unarmored & armored
14 AWG to 750 MCM / 600V

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 3
Insulated conductors are rated Vw1.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DRAKA MOG BOSTMARINE

DUSA_TN05_0905

CustRef TN-05
21
BOSTMARINE TYPE T/N POWER CABLE
four conductor power distribution / unarmored
14 AWG to 750 MCM / 600V
PVC/Nylon Jacket Unarmored Unarmored
TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight
Cable Type Number AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km
FT/NT-4 030104 14 2.1 7/24.2 0.015/0.38 0.004/0.10 0.045 1.14 0.39 9.9 151 225
FT/NT-6 030130 12 3.3 7/30.5 0.015/0.38 0.004/0.10 0.045 1.14 0.43 10.9 225 335
FT/NT-10 030128 10 5.3 7/38.5 0.020/0.51 0.004/0.10 0.045 1.14 0.51 13.0 366 545
FT/NT-16 030135 8 8.4 7/48.6 0.030/0.76 0.005//0.13 0.060 1.52 0.66 16.8 536 798
FT/NT-26 030134 6 13.3 7/61.2 0.030/0.76 0.005/0.13 0.060 1.52 0.77 19.6 878 1307
FT/NT-41 030133 4 21.1 7/77.2 0.040/1.02 0.006/0.15 0.080 2.03 0.99 25.1 1268 1887
FT/NT-66 030179 2 33.6 7/97.4 0.040//1.02 0.006/0.15 0.080 2.03 1.13 28.7 1598 2378
FT/NT-83 036114 1 42.4 19/66.4 0.050/1.27 0.007/0.18 0.080 2.03 1.27 32.3 1924 2863
FT/NT-106 036115 1/0 53.5 19/74.5 0.050/1.27 0.007/0.18 0.080 2.03 1.38 35.1 2374 3533
FT/NT-133 036116 2/0 67.4 19/83.7 0.050/1.27 0.007/0.18 0.080 2.03 1.49 37.8 2569 3823
FT/NT-168 036117 3/0 85.0 19/94.0 0.050/1.27 0.007/0.18 0.080 2.03 1.61 40.9 2850 4241
FT/NT-212 030177 4/0 107.2 19/105.5 0.050/1.27 0.007/0.18 0.110 2.79 1.82 46.2 3650 5432
FT/NT-250 036118 250 127.0 37/82.2 0.060/1.52 0.008/0.20 0.110 2.79 1.98 50.3 4319 6427
FT/NT-300 036119 300 152.0 37/90.0 0.060/1.52 0.008/0.20 0.110 2.79 2.11 53.6 5051 7517
FT/NT-350 036120 350 177.0 37/97.3 0.060/1.52 0.008/0.20 0.110 2.79 2.34 59.4 5866 8730
FT/NT-400 036121 400 203.0 37/104.0 0.060/1.52 0.008/0.20 0.110 2.79 2.46 62.5 6623 9856
FT/NT-500 036122 500 253.0 37/116.2 0.060/1.52 0.008/0.20 0.110 2.79 2.56 65.0 8086 12033
FT/NT-600 036123 600 304.0 61/99.2 0.070/1.78 0.009/0.23 0.140 3.56 2.87 72.9 9657 14371
FT/NT-750 036124 750 380.0 61/110.9 0.070/1.78 0.009/0.23 0.140 3.56 3.11 79.0 11949 17782

four conductor power distribution / aluminum or bronze armored


14 AWG to 750 MCM / 600V
PVC/Nylon Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
FT/NT-4 030104* 14 2.1 7/24.2 0.015/0.38 0.004/0.10 0.045 1.14 0.44 11.2 174 259 229 341
FT/NT-6 030130* 12 3.3 7/30.5 0.015/0.38 0.004/0.10 0.045 1.14 0.48 12.2 251 373 310 461
FT/NT-10 030128* 10 5.3 7/38.5 0.020/0.51 0.004/0.10 0.045 1.14 0.56 14.2 396 589 466 693
FT/NT-16 030135* 8 8.4 7/48.6 0.030/0.76 0.005//0.13 0.060 1.52 0.71 18.1 575 856 664 988
FT/NT-26 030134* 6 13.3 7/61.2 0.030/0.76 0.005/0.13 0.060 1.52 0.82 20.9 923 1373 1026 1527
FT/NT-41 030133* 4 21.1 7/77.2 0.040/1.02 0.006/0.15 0.080 2.03 1.04 26.4 1325 1971 1457 2168
FT/NT-66 030179* 2 33.6 7/97.4 0.040//1.02 0.006/0.15 0.080 2.03 1.18 30.0 1663 2475 1813 2698
FT/NT-83 036114* 1 42.4 19/66.4 0.050/1.27 0.007/0.18 0.080 2.03 1.32 33.8 1997 2972 2165 3222
FT/NT-106 036115* 1/0 53.5 19/74.5 0.050/1.27 0.007/0.18 0.080 2.03 1.43 36.3 2453 3650 2635 3921
FT/NT-133 036116* 2/0 67.4 19/83.7 0.050/1.27 0.007/0.18 0.080 2.03 1.54 39.1 2654 3949 2850 4241
FT/NT-168 036117* 3/0 85.0 19/94.0 0.050/1.27 0.007/0.18 0.080 2.03 1.66 42.2 2942 4378 3154 4693
FT/NT-212 030177* 4/0 107.2 19/105.5 0.050/1.27 0.007/0.18 0.110 2.79 1.87 47.5 3753 5584 3993 5942
FT/NT-250 036118* 250 127.0 37/82.2 0.060/1.52 0.008/0.20 0.110 2.79 2.03 51.6 4431 6593 4691 6980
FT/NT-300 036119* 300 152.0 37/90.0 0.060/1.52 0.008/0.20 0.110 2.79 2.16 54.9 5171 7694 5447 8105
FT/NT-350 036120* 350 177.0 37/97.3 0.060/1.52 0.008/0.20 0.110 2.79 2.39 60.7 5999 8927 6305 9382
FT/NT-400 036121* 400 203.0 37/104.0 0.060/1.52 0.008/0.20 0.110 2.79 2.51 63.8 6762 10062 7084 10541
FT/NT-500 036122* 500 253.0 37/116.2 0.060/1.52 0.008/0.20 0.110 2.79 2.61 66.3 8235 12254 8566 12746
FT/NT-600 036123* 600 304.0 61/99.2 0.070/1.78 0.009/0.23 0.140 3.56 2.92 74.2 9819 14611 10194 15169
FT/NT-750 036124* 750 380.0 61/110.9 0.070/1.78 0.009/0.23 0.140 3.56 3.16 80.3 12125 18042 12531 18646

*NOTE: For aluminum armored versions, add an A (ex. 030104A). For bronze armored versions, add a B (ex. 030104B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-06
22
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N POWER CABLE


three conductor power distribution / unarmored & armored
14 AWG to 750 MCM / 600V

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 3
Insulated conductors are rated VW1.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DRAKA MOG BOSTMARINE

DUSA_TN03_1005

CustRef TN-03
23
BOSTMARINE TYPE T/N POWER CABLE
three conductor power distribution / unarmored & armored
14 AWG to 750 MCM / 600V
PVC/Nylon Jacket Unarmored Unarmored
TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight
Cable Type Number AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km
TT/NT-4 030101 14 2.1 7/24.2 0.015/0.004 0.38/0.10 0.045 1.14 0.35 8.9 86 128
TT/NT-6 030102 12 3.3 7/30.5 0.015/0.004 0.38/0.10 0.045 1.14 0.39 9.9 120 179
TT/NT-10 030107 10 5.3 7/38.5 0.020/0.004 0.51/0.10 0.045 1.14 0.46 11.7 171 254
TT/NT-16 030106 8 8.4 7/48.6 0.030/0.005 0.76/0.13 0.060 1.52 0.61 15.5 301 448
TT/NT-26 030105 6 13.3 7/61.2 0.030/0.005 0.76/0.13 0.060 1.52 0.69 17.5 406 604
TT/NT-41 030110 4 21.1 7/77.2 0.040/0.006 1.02/0.15 0.080 2.03 0.84 21.3 664 988
TT/NT-66 030112 2 33.6 7/97.4 0.040/0.006 1.02/0.15 0.080 2.03 1.02 25.9 980 1458
TT/NT-83 036102 1 42.4 19/66.4 0.050/0.007 1.27/0.18 0.080 2.03 1.16 29.5 1228 1827
TT/NT-106 030178 1/0 53.5 19/74.5 0.050/0.007 1.27/0.18 0.080 2.03 1.24 31.5 1557 2317
TT/NT-133 036103 2/0 67.4 19/83.7 0.050/0.007 1.27/0.18 0.080 2.03 1.36 34.5 1828 2720
TT/NT-168 036104 3/0 85.0 19/94.0 0.050/0.007 1.27/0.18 0.080 2.03 1.45 36.8 2244 3339
TT/NT-212 036105 4/0 107.2 19/105.5 0.050/0.007 1.27/0.18 0.080 2.03 1.59 40.4 2773 4127
TT/NT-250 036106 250 127.0 37/82.2 0.060/0.008 1.52/0.20 0.110 2.79 1.80 45.7 3360 5000
TT/NT-300 036107 300 152.0 37/90.0 0.060/0.008 1.52/0.20 0.110 2.79 1.91 48.5 3920 5834
TT/NT-350 036108 350 177.0 37/97.3 0.060/0.008 1.52/0.20 0.110 2.79 2.05 52.1 4550 6771
TT/NT-400 036109 400 203.0 37/104.0 0.060/0.008 1.52/0.20 0.110 2.79 2.22 56.4 5133 7639
TT/NT-500 036110 500 253.0 37/116.2 0.060/0.008 1.52/0.20 0.110 2.79 2.45 62.2 6472 9631
TT/NT-600 036111 600 304.0 61/99.2 0.070/0.009 1.78/0.22 0.110 2.79 2.52 64.0 7375 10975
TT/NT-750 036112 750 380.0 61/110.9 0.070/0.009 1.78/0.22 0.110 2.79 2.83 71.9 9200 13691

three conductor power distribution / aluminum or bronze armored


14 AWG to 750 MCM / 600V
PVC/Nylon Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TT/NT-4 030101* 14 2.1 7/24.2 0.015/0.004 0.38/0.10 0.045 1.14 0.38 9.7 107 159 156 232
TT/NT-6 030102* 12 3.3 7/30.5 0.015/0.004 0.38/0.10 0.045 1.14 0.44 11.2 143 213 198 295
TT/NT-10 030107* 10 5.3 7/38.5 0.020/0.004 0.51/0.10 0.045 1.14 0.51 13.0 198 295 262 390
TT/NT-16 030106* 8 8.4 7/48.6 0.030/0.005 0.76/0.13 0.060 1.52 0.66 16.8 337 501 419 623
TT/NT-26 030105* 6 13.3 7/61.2 0.030/0.005 0.76/0.13 0.060 1.52 0.74 18.8 446 664 539 802
TT/NT-41 030110* 4 21.1 7/77.2 0.040/0.006 1.02/0.15 0.080 2.03 0.89 22.6 713 1061 825 1228
TT/NT-66 030112* 2 33.6 7/97.4 0.040/0.006 1.02/0.15 0.080 2.03 1.07 27.2 1039 1626 1174 1747
TT/NT-83 036102* 1 42.4 19/66.4 0.050/0.007 1.27/0.18 0.080 2.03 1.21 30.8 1295 1927 1448 2155
TT/NT-106 030178* 1/0 53.5 19/74.5 0.050/0.007 1.27/0.18 0.080 2.03 1.29 32.8 1628 2422 1792 2666
TT/NT-133 036103* 2/0 67.4 19/83.7 0.050/0.007 1.27/0.18 0.080 2.03 1.41 35.8 1906 2836 2085 3102
TT/NT-168 036104* 3/0 85.0 19/94.0 0.050/0.007 1.27/0.18 0.080 2.03 1.50 38.1 2327 3463 2518 3747
TT/NT-212 036105* 4/0 107.2 19/105.5 0.050/0.007 1.27/0.18 0.080 2.03 1.64 41.7 2864 4262 3073 4573
TT/NT-250 036106* 250 127.0 37/82.2 0.060/0.008 1.52/0.20 0.110 2.79 1.85 47.0 3462 5151 3699 5504
TT/NT-300 036107* 300 152.0 37/90.0 0.060/0.008 1.52/0.20 0.110 2.79 1.96 49.8 4029 5995 4280 6369
TT/NT-350 036108* 350 177.0 37/97.3 0.060/0.008 1.52/0.20 0.110 2.79 2.10 53.4 4666 6943 4935 7343
TT/NT-400 036109* 400 203.0 37/104.0 0.060/0.008 1.52/0.20 0.110 2.79 2.27 57.7 5259 7825 5550 8258
TT/NT-500 036110* 500 253.0 37/116.2 0.060/0.008 1.52/0.20 0.110 2.79 2.50 63.5 6611 9837 6932 10315
TT/NT-600 036111* 600 304.0 61/99.2 0.070/0.009 1.78/0.22 0.110 2.79 2.57 65.3 7518 11187 7847 11676
TT/NT-750 036112* 750 380.0 61/110.9 0.070/0.009 1.78/0.22 0.110 2.79 2.88 73.2 9360 13928 9730 14478

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-04
24
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N POWER CABLE


two conductor power distribution / unarmored & armored
14 AWG to 500 MCM / 600V

APPLICATIONS
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 3
Insulated conductors are rated VW1.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-500
DRAKA MOG BOSTMARINE

DUSA_TN01_1005

CustRef TN-01
25
BOSTMARINE TYPE T/N POWER CABLE
two conductor power distribution / unarmored & armored
14 AWG to 500 MCM / 600V
PVC/Nylon Jacket Unarmored Unarmored
TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight
Cable Type Number AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km
DT/NT-4 030103 14 2.1 7/24.2 0.015/0.004 0.38/0.10 0.045 1.14 0.33 8.4 66 98
DT/NT-6 030123 12 3.3 7/30.5 0.015/0.004 0.38/0.10 0.045 1.14 0.37 9.4 88 131
DT/NT-10 030114 10 5.3 7/38.5 0.020/0.004 0.51/0.10 0.045 1.14 0.43 10.9 133 198
DT/NT-16 030138 8 8.4 7/48.6 0.030/0.005 0.76/0.13 0.060 1.52 0.58 14.7 216 321
DT/NT-26 030139 6 13.3 7/61.2 0.030/0.005 0.76/0.13 0.060 1.52 0.65 16.5 311 463
DT/NT-41 030182 4 21.1 7/77.2 0.040/0.006 1.02/0.15 0.060 1.52 0.80 20.3 479 713
DT/NT-66 036090 2 33.6 7/97.4 0.040/0.006 1.02/0.15 0.080 2.03 0.97 24.6 727 1082
DT/NT-83 036091 1 42.4 19/66.4 0.050/0.007 1.27/0.18 0.080 2.03 1.00 25.4 933 1388
DT/NT-106 036092 1/0 53.5 19/74.5 0.050/0.007 1.27/0.18 0.080 2.03 1.18 30.0 1110 1652
DT/NT-133 036093 2/0 67.4 19/83.7 0.050/0.007 1.27/0.18 0.080 2.03 1.27 32.3 1323 1969
DT/NT-168 036094 3/0 85.0 19/94.0 0.050/0.007 1.27/0.18 0.080 2.03 1.38 35.1 1602 2384
DT/NT-212 036095 4/0 107.2 19/105.5 0.050/0.007 1.27/0.18 0.080 2.03 1.56 39.6 2122 3158
DT/NT-250 036096 250 127.0 37/82.2 0.060/0.080 1.52/2.03 0.080 2.03 1.62 41.1 2337 3478
DT/NT-300 036097 300 152.0 37/90.0 0.060/0.080 1.52/2.03 0.110 2.79 1.80 45.7 2851 4243
DT/NT-350 036049 350 177.0 37/97.3 0.060/0.080 1.52/2.03 0.110 2.79 1.90 48.3 3303 4915
DT/NT-400 036098 400 203.0 37/104.0 0.060/0.080 1.52/2.03 0.110 2.79 2.08 52.8 3662 5450
DT/NT-500 036099 500 253.0 37/116.2 0.060/0.080 1.52/2.03 0.110 2.79 2.17 55.1 4497 6692

two conductor power distribution / aluminum or bronze armored


14 AWG to 750 MCM / 600V
PVC/Nylon Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Size Stranding Insulation Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
DT/NT-4 030103* 14 2.1 7/24.2 0.015/0.004 0.38/0.10 0.045 1.14 0.38 9.7 86 128 132 196
DT/NT-6 030123* 12 3.3 7/30.5 0.015/0.004 0.38/0.10 0.045 1.14 0.42 10.7 110 164 162 240
DT/NT-10 030114* 10 5.3 7/38.5 0.020/0.004 0.51/0.10 0.045 1.14 0.48 12.5 159 237 218 324
DT/NT-16 030138* 8 8.4 7/48.6 0.030/0.005 0.76/0.13 0.060 1.52 0.63 16.0 250 372 329 490
DT/NT-26 030139* 6 13.3 7/61.2 0.030/0.005 0.76/0.13 0.060 1.52 0.70 17.8 351 522 437 650
DT/NT-41 030182* 4 21.1 7/77.2 0.040/0.006 1.02/0.15 0.060 1.52 0.85 21.6 530 789 633 942
DT/NT-66 036090* 2 33.6 7/97.4 0.040/0.006 1.02/0.15 0.080 2.03 1.02 25.9 791 1177 912 1357
DT/NT-83 036091* 1 42.4 19/66.4 0.050/0.007 1.27/0.18 0.080 2.03 1.05 26.7 991 1475 1124 1673
DT/NT-106 036092* 1/0 53.5 19/74.5 0.050/0.007 1.27/0.18 0.080 2.03 1.23 31.3 1178 1753 1334 1985
DT/NT-133 036093* 2/0 67.4 19/83.7 0.050/0.007 1.27/0.18 0.080 2.03 1.32 33.6 1396 2077 1564 2327
DT/NT-168 036094* 3/0 85.0 19/94.0 0.050/0.007 1.27/0.18 0.080 2.03 1.43 36.3 1681 2501 1863 2772
DT/NT-212 036095* 4/0 107.2 19/105.5 0.050/0.007 1.27/0.18 0.080 2.03 1.61 40.9 2211 3290 2416 3595
DT/NT-250 036096* 250 127.0 37/82.2 0.060/0.080 1.52/2.03 0.080 2.03 1.67 42.4 2429 3614 2643 3933
DT/NT-300 036097* 300 152.0 37/90.0 0.060/0.080 1.52/2.03 0.110 2.79 1.85 47.0 2953 4394 3190 4747
DT/NT-350 036049* 350 177.0 37/97.3 0.060/0.080 1.52/2.03 0.110 2.79 1.95 49.6 3411 5076 3660 5446
DT/NT-400 036098* 400 203.0 37/104.0 0.060/0.080 1.52/2.03 0.110 2.79 2.13 54.1 3780 5625 4053 6031
DT/NT-500 036099* 500 253.0 37/116.2 0.060/0.080 1.52/2.03 0.110 2.79 2.22 56.4 4620 6875 4904 7297

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-02
26
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
14 AWG 2.1 mm2 / 600V
DRAKA-USA

APPLICATIONS ISO9001
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica- QSC3497
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and 1
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION 3
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 4
Insulated conductors are rated VW1.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-510
DRAKA MOG BOSTMARINE

DUSA_TN15_1005

CustRef TN-15
27
BOSTMARINE TYPE T/N SIGNAL CABLE
indiv. & overall shielded twisted pair / unarmored & armored
14 AWG 2.1 mm2 / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP14(IS-OS)T/NT-1 350356 1 7/24.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.340 8.6 73 109
TP14(IS-OS)T/NT-2 350357 2 7/24.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.575 14.6 175 260
TP14(IS-OS)T/NT-3 350358 3 7/24.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.605 15.4 228 339
TP14(IS-OS)T/NT-4 350360 4 7/24.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.665 16.9 282 420
TP14(IS-OS)T/NT-6 350361 6 7/24.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.790 20.1 392 583

indiv. & overall shielded twisted pair / aluminum or bronze armored


14 AWG 2.1 mm2 / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP14(IS-OS)T/NT-1 350356* 1 7/24.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.400 10.2 94 140 143 213
TP14(IS-OS)T/NT-2 350357* 2 7/24.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.635 16.1 210 312 290 432
TP14(IS-OS)T/NT-3 350358* 3 7/24.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.665 16.9 264 393 348 518
TP14(IS-OS)T/NT-4 350360* 4 7/24.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.725 18.4 322 479 414 616
TP14(IS-OS)T/NT-6 350361* 6 7/24.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.850 21.6 439 653 547 814

*NOTE: For aluminum armored versions, add an A (ex. 350356A). For bronze armored versions, add a B (ex. 350356B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-16
28
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
16 AWG 1.3 mm2 / 600V
DRAKA-USA

APPLICATIONS ISO9001
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica- QSC3497
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and 1
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION 3
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 4
Insulated conductors are rated VW1.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-510
DRAKA MOG BOSTMARINE

DUSA_TN13_1005

CustRef TN-13
29
BOSTMARINE TYPE T/N SIGNAL CABLE
indiv. & overall shielded twisted pair / unarmored & armored
16 AWG 1.3 mm2 / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP16(IS)T/NT-1 030160 1 7/19.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.29 7.4 49 72
TP16(IS-OS)T/NT-2 030162 2 7/19.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.43 11.0 58 86
TP16(IS-OS)T/NT-3 036194 3 7/19.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.46 11.7 124 184
TP16(IS-OS)T/NT-4 030164 4 7/19.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.50 12.8 155 231
TP16(IS-OS)T/NT-5 036196 5 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.58 14.8 205 306
TP16(IS-OS)T/NT-6 030165 6 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.63 16.1 240 356
TP16(IS-OS)T/NT-7 036198 7 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.63 16.1 268 398
TP16(IS-OS)T/NT-8 030166 8 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.69 17.4 300 446
TP16(IS-OS)T/NT-9 036200 9 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.74 18.8 337 502
TP16(IS-OS)T/NT-10 036201 10 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.81 20.4 373 555
TP16(IS-OS)T/NT-11 036202 11 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.88 22.2 401 597
TP16(IS-OS)T/NT-12 036203 12 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.88 22.2 466 693
TP16(IS-OS)T/NT-13 036204 13 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.92 23.3 501 746
TP16(IS-OS)T/NT-14 036205 14 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.92 23.3 530 788
TP16(IS-OS)T/NT-15 030161 15 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.97 24.6 566 842
TP16(IS-OS)T/NT-16 036207 16 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.97 24.6 594 884
TP16(IS-OS)T/NT-17 036208 17 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.02 25.9 630 938
TP16(IS-OS)T/NT-18 036209 18 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.02 25.9 659 981
TP16(IS-OS)T/NT-19 036210 19 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.02 25.9 687 1023
TP16(IS-OS)T/NT-20 030163 20 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.07 27.2 724 1077
TP16(IS-OS)T/NT-21 036212 21 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.07 27.2 752 1119
TP16(IS-OS)T/NT-22 036213 22 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.12 28.5 789 1174

indiv. & overall shielded twisted pair / aluminum or bronze armored


16 AWG 1.3 mm2 / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP16(IS)T/NT-1 030160* 1 7/19.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.34 8.7 67 100 108 161
TP16(IS-OS)T/NT-2 030162* 2 7/19.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.48 12.2 84 125 143 213
TP16(IS-OS)T/NT-3 036194* 3 7/19.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.51 13.0 151 225 215 320
TP16(IS-OS)T/NT-4 030164* 4 7/19.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.55 14.0 185 275 253 376
TP16(IS-OS)T/NT-5 036196* 5 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.63 16.0 239 356 318 473
TP16(IS-OS)T/NT-6 030165* 6 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.68 17.3 277 412 362 539
TP16(IS-OS)T/NT-7 036198* 7 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.68 17.3 305 454 390 580
TP16(IS-OS)T/NT-8 030166* 8 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.74 18.8 340 506 433 644
TP16(IS-OS)T/NT-9 036200* 9 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.79 20.1 380 565 479 713
TP16(IS-OS)T/NT-10 036201* 10 7/19.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.86 21.9 420 625 528 786
TP16(IS-OS)T/NT-11 036202* 11 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.93 23.6 452 673 569 847
TP16(IS-OS)T/NT-12 036203* 12 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.93 23.6 517 769 634 943
TP16(IS-OS)T/NT-13 036204* 13 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.97 24.7 554 824 677 1007
TP16(IS-OS)T/NT-14 036205* 14 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.97 24.7 583 868 706 1051
TP16(IS-OS)T/NT-15 030161* 15 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.02 25.9 622 926 751 1117
TP16(IS-OS)T/NT-16 036207* 16 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.02 25.9 650 967 779 1159
TP16(IS-OS)T/NT-17 036208* 17 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.07 27.2 689 1025 824 1226
TP16(IS-OS)T/NT-18 036209* 18 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.07 27.2 718 1068 853 1269
TP16(IS-OS)T/NT-19 036210* 19 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.07 27.2 746 1110 881 1311
TP16(IS-OS)T/NT-20 030163* 20 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.12 28.5 786 1170 928 1381
TP16(IS-OS)T/NT-21 036212* 21 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.12 28.5 814 1211 956 1423
TP16(IS-OS)T/NT-22 036213* 22 7/19.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.17 29.7 853 1269 1002 1491

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-14
30
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
18 AWG 0.82 mm2 / 600V
DRAKA-USA

APPLICATIONS ISO9001
BOSTMARINE Type T/N 600 volt cables are suitable for use in commercial marine applica- QSC3497
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and 1
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 600 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION 3
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 4
Insulated conductors are rated VW1.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-510
DRAKA MOG BOSTMARINE

DUSA_TN11_0905

CustRef TN-11
31
BOSTMARINE TYPE T/N SIGNAL CABLE
indiv. & overall shielded twisted pair / unarmored & armored
18 AWG 0.82 mm2 / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP18(IS)T/NT-1 029504 1 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.27 6.8 40 59
TP18(IS-OS)T/NT-2 030171 2 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.39 10.0 74 111
TP18(IS-OS)T/NT-3 029509 3 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.42 10.6 97 145
TP18(IS-OS)T/NT-4 030173 4 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.46 11.6 122 181
TP18(IS-OS)T/NT-5 029511 5 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.50 12.7 147 218
TP18(IS-OS)T/NT-6 036176 6 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.57 14.6 189 282
TP18(IS-OS)T/NT-7 029514 7 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.57 14.6 210 313
TP18(IS-OS)T/NT-8 030174 8 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.62 15.7 237 352
TP18(IS-OS)T/NT-9 036179 9 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.67 16.9 263 392
TP18(IS-OS)T/NT-10 029503 10 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.72 18.4 291 433
TP18(IS-OS)T/NT-11 036180 11 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.75 19.0 312 465
TP18(IS-OS)T/NT-12 030170 12 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.75 19.0 336 500
TP18(IS-OS)T/NT-13 036182 13 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.79 20.0 361 538
TP18(IS-OS)T/NT-14 036183 14 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.79 20.0 383 570
TP18(IS-OS)T/NT-15 036184 15 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.87 22.1 442 659
TP18(IS-OS)T/NT-16 036185 16 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.87 22.1 464 690
TP18(IS-OS)T/NT-17 036186 17 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.92 23.3 492 732
TP18(IS-OS)T/NT-18 036187 18 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.92 23.3 513 763
TP18(IS-OS)T/NT-19 036188 19 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.92 23.3 534 795
TP18(IS-OS)T/NT-20 029507 20 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.96 24.5 562 837
TP18(IS-OS)T/NT-21 036190 21 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.96 24.5 584 868
TP18(IS-OS)T/NT-22 036191 22 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.01 25.7 613 912

indiv. & overall shielded twisted pair / aluminum or bronze armored


18 AWG 0.82 mm2 / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP18(IS)T/NT-1 029504* 1 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.32 8.2 57 85 95 141
TP18(IS-OS)T/NT-2 030171* 2 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.44 11.2 97 144 152 226
TP18(IS-OS)T/NT-3 029509* 3 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.47 12.0 122 182 180 268
TP18(IS-OS)T/NT-4 030173* 4 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.40 10.2 149 222 213 317
TP18(IS-OS)T/NT-5 029511* 5 7/15.2 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.55 14.0 177 263 245 365
TP18(IS-OS)T/NT-6 036176* 6 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.62 15.8 223 332 300 446
TP18(IS-OS)T/NT-7 029514* 7 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.62 15.8 244 363 321 478
TP18(IS-OS)T/NT-8 030174* 8 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.67 17.0 273 406 257 382
TP18(IS-OS)T/NT-9 036179* 9 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.72 18.3 302 449 393 585
TP18(IS-OS)T/NT-10 029503* 10 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.77 19.6 333 496 430 640
TP18(IS-OS)T/NT-11 036180* 11 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.80 20.3 356 530 456 679
TP18(IS-OS)T/NT-12 030170* 12 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.80 20.3 380 565 480 714
TP18(IS-OS)T/NT-13 036182* 13 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.84 21.4 407 606 513 763
TP18(IS-OS)T/NT-14 036183* 14 7/15.2 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.84 21.4 429 638 535 796
TP18(IS-OS)T/NT-15 036184* 15 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.92 23.4 492 732 608 905
TP18(IS-OS)T/NT-16 036185* 16 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.92 23.4 514 765 630 937
TP18(IS-OS)T/NT-17 036186* 17 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.97 24.7 545 811 668 994
TP18(IS-OS)T/NT-18 036187* 18 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.97 24.7 566 842 689 1025
TP18(IS-OS)T/NT-19 036188* 19 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.97 24.7 587 873 710 1056
TP18(IS-OS)T/NT-20 029507* 20 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.01 25.7 617 918 745 1109
TP18(IS-OS)T/NT-21 036190* 21 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.01 25.7 639 951 767 1141
TP18(IS-OS)T/NT-22 036191* 22 7/15.2 0.015 / 0.004 0.38 / 0.10 0.080 2.03 1.06 26.9 671 998 806 1199

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-12
32
Draka Marine Shipboard Cables

BOSTMARINE TYPE T/N SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
20 AWG 0.52 mm2 / 300V
DRAKA-USA

APPLICATIONS ISO9001
BOSTMARINE Type T/N 300 volt cables are suitable for use in commercial marine applica- QSC3497
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and 1
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE-1580 (2001) and UL 1309 for 300 volts. Type
T/N cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION 3
1. CONDUCTORS
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998),
IEEE 1580 (2001) and UL 1309/CSA 245. Thickness as shown in tables on the reverse. 4
Insulated conductors are rated VW1.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA245.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 99/60004/E1.
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-510
DRAKA MOG BOSTMARINE

DUSA_TN09_1005

CustRef TN-09
33
BOSTMARINE TYPE T/N SIGNAL CABLE
indiv. & overall shielded twisted pair / unarmored
20 AWG 0.52 mm2 / 300V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP20(IS)T/NT-1 030190 1 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.25 6.3 33 49
TP20(IS-OS)T/NT-2 030193 2 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.36 9.1 61 91
TP20(IS-OS)T/NT-3 030194 3 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.38 9.7 80 119
TP20(IS-OS)T/NT-4 030195 4 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.41 10.5 99 147
TP20(IS-OS)T/NT-5 036154 5 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.45 11.5 118 175
TP20(IS-OS)T/NT-6 036155 6 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.49 12.5 137 204
TP20(IS-OS)T/NT-7 036156 7 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.49 12.5 153 228
TP20(IS-OS)T/NT-8 036157 8 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.56 14.3 186 277
TP20(IS-OS)T/NT-9 036158 9 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.61 15.4 211 314
TP20(IS-OS)T/NT-10 029501 10 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.66 16.7 229 341
TP20(IS-OS)T/NT-11 036159 11 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.68 17.2 245 365
TP20(IS-OS)T/NT-12 030191 12 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.68 17.2 267 397
TP20(IS-OS)T/NT-13 036161 13 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.71 18.1 287 427
TP20(IS-OS)T/NT-14 036162 14 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.71 18.1 303 450
TP20(IS-OS)T/NT-15 036163 15 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.75 19.1 323 481
TP20(IS-OS)T/NT-16 036164 16 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.75 19.1 339 504
TP20(IS-OS)T/NT-17 036165 17 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.79 20.2 360 535
TP20(IS-OS)T/NT-18 036166 18 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.79 20.2 375 559
TP20(IS-OS)T/NT-19 036167 19 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.79 20.2 391 582
TP20(IS-OS)T/NT-20 036168 20 7/12.1 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.88 22.2 447 665
TP20(IS-OS)T/NT-21 036169 21 7/12.1 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.88 22.2 463 689
TP20(IS-OS)T/NT-22 036170 22 7/12.1 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.92 23.3 485 722

indiv. & overall shielded twisted pair / aluminum or bronze armored


20 AWG 0.52 mm2 / 300V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP20(IS)T/NT-1 030190* 1 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.30 7.6 49 73 86 128
TP20(IS-OS)T/NT-2 030193* 2 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.41 10.4 83 135 135 201
TP20(IS-OS)T/NT-3 030194* 3 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.43 10.9 103 153 158 235
TP20(IS-OS)T/NT-4 030195* 4 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.46 11.7 124 185 182 271
TP20(IS-OS)T/NT-5 036154* 5 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.50 12.7 145 216 209 311
TP20(IS-OS)T/NT-6 036155* 6 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.54 13.7 167 248 236 351
TP20(IS-OS)T/NT-7 036156* 7 7/12.1 0.015 / 0.004 0.38 / 0.10 0.045 1.14 0.54 13.7 183 272 252 375
TP20(IS-OS)T/NT-8 036157* 8 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.61 15.5 220 327 298 443
TP20(IS-OS)T/NT-9 036158* 9 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.66 15.4 248 369 332 494
TP20(IS-OS)T/NT-10 029501* 10 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.71 18.0 269 400 360 536
TP20(IS-OS)T/NT-11 036159* 11 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.73 18.5 286 426 380 565
TP20(IS-OS)T/NT-12 030191* 12 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.73 18.5 308 458 402 598
TP20(IS-OS)T/NT-13 036161* 13 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.76 19.3 329 490 427 635
TP20(IS-OS)T/NT-14 036162* 14 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.76 19.3 345 513 443 695
TP20(IS-OS)T/NT-15 036163* 15 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.80 20.3 368 548 471 701
TP20(IS-OS)T/NT-16 036164* 16 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.80 20.3 384 571 487 725
TP20(IS-OS)T/NT-17 036165* 17 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.84 21.3 407 606 515 766
TP20(IS-OS)T/NT-18 036166* 18 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.84 21.3 422 628 530 789
TP20(IS-OS)T/NT-19 036167* 19 7/12.1 0.015 / 0.004 0.38 / 0.10 0.060 1.52 0.84 21.3 438 652 546 812
TP20(IS-OS)T/NT-20 036168* 20 7/12.1 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.93 23.6 499 743 620 923
TP20(IS-OS)T/NT-21 036169* 21 7/12.1 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.93 22.2 515 766 636 946
TP20(IS-OS)T/NT-22 036170* 22 7/12.1 0.015 / 0.004 0.38 / 0.10 0.080 2.03 0.97 23.3 539 802 665 990

*NOTE: For aluminum armored versions, add an A (ex. 030103A). For bronze armored versions, add a B (ex. 036150B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef TN-10
34
Draka Marine Shipboard Cables

BOSTMARINE TYPE X CONTROL CABLE


multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V

APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600 1
volts. Type X cables are Type Approved by ABS and LRS.
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001)
2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated 3
VW1. Thickness as shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-501
DRAKA MOG BOSTMARINE

DUSA_X07_1005

CustRef X-07
35
BOSTMARINE TYPE X CONTROL CABLE
multi-conductor / unarmored & armored
18, 16 and 14 AWG / 600V
18 AWG 1.0 mm2
Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C18XT-2 036570 2 7/15.2 0.030 0.76 0.045 1.14 0.32 8.0 47 70 0.375 9.5 67 100 113 168
C18XT-3 036571 3 7/15.2 0.030 0.76 0.045 1.14 0.33 8.4 56 83 0.385 9.8 77 115 124 185
C18XT-4 036572 4 7/15.2 0.030 0.76 0.045 1.14 0.36 9.1 68 101 0.415 10.5 90 134 142 211
C18XT-7 036573 7 7/15.2 0.030 0.76 0.045 1.14 0.42 10.8 99 147 0.475 12.1 125 186 184 274
C18XT-10 036574 10 7/15.2 0.030 0.76 0.060 1.52 0.56 14.4 153 228 0.615 15.6 187 278 265 394
C18XT-14 036575 14 7/15.2 0.030 0.76 0.060 1.52 0.61 15.5 195 290 0.665 16.9 232 345 316 470
C18XT-19 036576 19 7/15.2 0.030 0.76 0.060 1.52 0.67 17.0 250 372 0.725 18.4 290 432 383 570
C18XT-24 036577 24 7/15.2 0.030 0.76 0.060 1.52 0.78 19.8 308 458 0.835 21.2 354 527 462 687
C18XT-30 036578 30 7/15.2 0.030 0.76 0.080 2.03 0.88 22.4 370 551 0.915 23.2 422 628 543 808
C18XT-37 036579 37 7/15.2 0.030 0.76 0.080 2.03 0.93 23.6 480 714 0.985 25.0 535 796 662 985
C18XT-44 036580 44 7/15.2 0.030 0.76 0.080 2.03 1.03 26.2 547 814 1.085 27.6 608 905 748 1113
C18XT-61 036581 61 7/15.2 0.030 0.76 0.080 2.03 1.10 27.9 696 1036 1.155 29.3 761 1132 910 1354

16 AWG 1.3 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C16XT-2 036582 2 7/19.2 0.030 0.76 0.045 1.14 0.34 8.6 57 85 0.395 10.0 78 116 127 189
C16XT-3 036583 3 7/19.2 0.030 0.76 0.045 1.14 0.36 9.1 71 106 0.415 10.5 93 138 145 216
C16XT-4 036584 4 7/19.2 0.030 0.76 0.045 1.14 0.39 9.9 87 129 0.445 11.3 111 165 167 248
C16XT-7 036585 7 7/19.2 0.030 0.76 0.045 1.14 0.46 11.7 129 192 0.515 13.1 157 234 222 330
C16XT-10 036053 10 7/19.2 0.030 0.76 0.060 1.52 0.61 15.6 197 293 0.665 16.9 234 348 318 473
C16XT-14 036586 14 7/19.2 0.030 0.76 0.060 1.52 0.67 16.9 255 379 0.725 18.4 295 439 388 577
C16XT-19 036587 19 7/19.2 0.030 0.76 0.060 1.52 0.73 18.7 328 488 0.785 19.9 372 553 472 702
C16XT-24 036588 24 7/19.2 0.030 0.76 0.080 2.03 0.90 22.9 444 661 0.955 24.3 497 740 620 923
C16XT-30 036589 30 7/19.2 0.030 0.76 0.080 2.03 0.95 24.1 529 787 1.005 25.5 585 870 715 1064
C16XT-37 036590 37 7/19.2 0.030 0.76 0.080 2.03 1.02 25.9 631 939 1.075 27.3 691 1028 830 1235
C16XT-44 036591 44 7/19.2 0.030 0.76 0.080 2.03 1.16 29.3 748 1113 1.215 30.9 816 1214 974 1449
C16XT-61 036592 61 7/19.2 0.030 0.76 0.080 2.03 1.27 32.4 980 1458 1.325 33.7 1054 1568 1227 1825

14 AWG 2.1 mm2


Insulation Jacket Cable Diameter Cable Weight Armored Cable Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness (nom) (approx) Diameter (nom) Cable Weight Cable Weight
Cable Type Number* Conductors Type in mm in mm in mm Lbs/mft Kg/km in mm Lbs/mft Kg/km Lbs/mft Kg/km
C14XT-2 036593 2 7/24.2 0.030 0.76 0.045 1.14 0.37 9.4 72 107 0.425 10.8 95 141 148 220
C14XT-3 036594 3 7/24.2 0.030 0.76 0.045 1.14 0.39 9.9 92 137 0.445 11.3 116 173 172 256
C14XT-4 036595 4 7/24.2 0.030 0.76 0.045 1.14 0.42 10.8 114 170 0.475 12.1 140 208 199 296
C14XT-7 036057 7 7/24.2 0.030 0.76 0.045 1.14 0.51 12.8 173 257 0.565 14.4 204 306 275 409
C14XT-10 036596 10 7/24.2 0.030 0.76 0.060 1.52 0.68 17.1 261 388 0.735 18.7 302 449 396 589
C14XT-14 036058 14 7/24.2 0.030 0.76 0.060 1.52 0.73 18.5 342 509 0.785 19.9 386 574 486 723
C14XT-19 036597 19 7/24.2 0.030 0.76 0.060 1.52 0.81 20.6 444 661 0.865 22.0 492 732 603 897
C14XT-24 036059 24 7/24.2 0.030 0.76 0.080 2.03 0.99 25.1 593 882 1.045 26.5 651 969 786 1170
C14XT-30 036598 30 7/24.2 0.030 0.76 0.080 2.03 1.05 26.7 714 1063 1.105 28.1 776 1155 919 1367
C14XT-37 036599 37 7/24.2 0.030 0.76 0.080 2.03 1.13 28.7 856 1274 1.185 30.1 922 1372 1076 1601
C14XT-44 036600 44 7/24.2 0.030 0.76 0.080 2.03 1.27 32.3 1010 1503 1.325 33.7 1084 1613 1257 1870
C14XT-61 036601 61 7/24.2 0.030 0.76 0.080 2.03 1.40 35.4 1350 2009 1.455 37.0 1432 2131 1621 2412

*NOTE: For aluminum armored versions, add an A (ex. 036570A). For bronze armored versions, add a B (ex. 036570B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef X-08
36
Draka Marine Shipboard Cables

BOSTMARINE TYPE X POWER CABLE


four conductor / unarmored & armored
14 AWG to 500 MCM / 600V

APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION
2
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated 3
VW1. Thickness as shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-501
DRAKA MOG BOSTMARINE

DUSA_X05_1005

CustRef X-05
37
BOSTMARINE TYPE X POWER CABLE
four conductor / unarmored
14 AWG to 500 MCM / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Conductor Size Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km
FXT-4 036563 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.440 11.2 120 179
FXT-6 036564 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.485 12.3 164 244
FXT-10 036052 10 5.3 7/38.5 0.030 0.76 0.060 1.52 0.575 14.6 241 359
FXT-16 036565 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.730 18.5 382 568
FXT-26 036566 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.830 21.1 542 806
FXT-41 036015 4 21.1 7/77.2 0.045 1.14 0.080 2.03 0.990 25.1 824 1226
FXT-66 036011 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.140 29.0 1205 1793
FXT-83 030143 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.290 32.8 1500 2232
FXT-106 030144 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.390 35.3 1782 2652
FXT-133 030145 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.500 38.1 2220 3303
FXT-168 030146 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.625 41.3 2706 4027
FXT-212 030147 4/0 107.2 19/105.5 0.055 1.40 0.110 2.79 1.830 46.5 3444 5125
FXT-250 030183 250 127.0 37/82.2 0.065 1.65 0.110 2.79 2.000 50.8 4002 5955
FXT-300 036568 300 152.0 37/90.0 0.065 1.65 0.110 2.79 2.130 54.1 4680 6964
FXT-350 030389 350 177.0 37/97.3 0.065 1.65 0.110 2.79 2.260 57.4 5464 8130
FXT-400 036569 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.370 60.2 6140 9136
FXT-500 030647 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.580 65.5 7560 11250

four conductor / aluminum or bronze armored


14 AWG to 500 MCM / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Size Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
FXT-4 036563* 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.495 12.6 147 219 209 311
FXT-6 036564* 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.540 13.7 193 287 262 390
FXT-10 036052* 10 5.3 7/38.5 0.030 0.76 0.060 1.52 0.630 16.0 276 411 356 530
FXT-16 036565* 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.785 19.9 426 634 526 783
FXT-26 036566* 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.885 22.5 591 879 705 1049
FXT-41 036015* 4 21.1 7/77.2 0.045 1.14 0.080 2.03 1.045 26.5 882 1312 1017 1513
FXT-66 036011* 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.195 30.4 1272 1893 1427 2123
FXT-83 030143* 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.345 34.2 1576 2345 1750 2604
FXT-106 030144* 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.445 36.7 1863 2772 2051 3052
FXT-133 030145* 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.555 39.5 2308 3434 2510 3735
FXT-168 030146* 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.680 42.7 2801 4168 3020 4494
FXT-212 030147* 4/0 107.2 19/105.5 0.055 1.40 0.110 2.79 1.885 47.9 3551 5284 3797 5650
FXT-250 030183* 250 127.0 37/82.2 0.065 1.65 0.110 2.79 2.055 52.2 4118 6128 4387 6528
FXT-300 036568* 300 152.0 37/90.0 0.065 1.65 0.110 2.79 2.185 55.5 4804 7148 5090 7574
FXT-350 030389* 350 177.0 37/97.3 0.065 1.65 0.110 2.79 2.315 58.8 5595 8325 5899 8778
FXT-400 036569* 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.425 61.6 6278 9342 6595 9813
FXT-500 030647* 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.635 66.9 7710 11472 8055 11986

*NOTE: For aluminum armored versions, add an A (ex. 036563A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 1281-209-3857 fax www.drakausa.com

CustRef X-06
38
Draka Marine Shipboard Cables

BOSTMARINE TYPE X POWER CABLE


three conductor / unarmored & armored
14 AWG to 1000 MCM / 600V

APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION
2
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated 3
VW1. Thickness as shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-501
DRAKA MOG BOSTMARINE

DUSA_X03_1005

CustRef X-03
39
BOSTMARINE TYPE X POWER CABLE
three conductor / unarmored
14 AWG to 1000 MCM / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Size Type in mm in mm in mm Lbs/mft Kg/km
TXT-4 030125 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.400 10.2 90 134
TXT-6 030113 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.440 11.2 120 179
TXT-10 036010 10 5.3 7/38.5 0.030 0.76 0.045 1.14 0.500 12.7 170 253
TXT-16 036009 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.670 17.1 280 417
TXT-26 036055 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.750 19.1 395 588
TXT-41 036008 4 21.1 7/77.2 0.045 1.14 0.080 2.03 0.900 23.0 570 848
TXT-66 036007 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.030 26.2 875 1302
TXT-83 030126 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.160 29.5 1090 1622
TXT-106 030127 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.255 31.9 1320 1964
TXT-133 030140 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.355 34.4 1615 2403
TXT-168 030141 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.470 37.3 1980 2947
TXT-212 030142 4/0 107.2 19/105.5 0.055 1.40 0.080 2.03 1.595 40.5 2435 3624
TXT-250 030158 250 127.0 37/82.2 0.065 1.65 0.110 2.79 1.810 46.0 2965 4412
TXT-300 036559 300 152.0 37/90.0 0.065 1.65 0.110 2.79 1.930 49.0 3485 5186
TXT-350 030124 350 177.0 37/97.3 0.065 1.65 0.110 2.79 2.040 51.8 4005 5960
TXT-400 030200 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.140 54.4 4525 6734
TXT-500 030647 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.330 59.2 5545 8252
TXT-750 036561 750 380.0 61/110.9 0.080 2.03 0.140 3.56 2.865 72.8 8420 12530
TXT-1000 036562 1000 507.0 61/128.0 0.080 2.03 0.140 3.56 3.200 81.3 11000 16370

three conductor / aluminum or bronze armored


14 AWG to 1000 MCM / 600V
Insulationj Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Size Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TXT-4 030125* 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.440 11.2 115 171 171 254
TXT-6 030113* 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.490 12.5 147 219 209 311
TXT-10 036010* 10 5.3 7/38.5 0.030 0.76 0.045 1.14 0.550 14.0 200 298 270 402
TXT-16 036009* 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.720 18.3 320 476 413 615
TXT-26 036055* 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.880 22.4 440 655 543 808
TXT-41 036008* 4 21.1 7/77.2 0.045 1.14 0.080 2.03 0.950 24.2 623 927 746 1110
TXT-66 036007* 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.080 27.6 936 1393 1076 1601
TXT-83 030126* 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.210 30.8 1158 1732 1316 1958
TXT-106 030127* 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.310 33.3 1394 2074 1564 2327
TXT-133 030140* 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.410 35.8 1694 2521 1878 2794
TXT-168 030141* 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.520 38.6 2066 3074 2265 3370
TXT-212 030142* 4/0 107.2 19/105.5 0.055 1.40 0.080 2.03 1.650 41.9 2528 3762 2743 4082
TXT-250 030158* 250 127.0 37/82.2 0.065 1.65 0.110 2.79 1.860 47.3 3070 4568 3314 4931
TXT-300 036559* 300 152.0 37/90.0 0.065 1.65 0.110 2.79 1.980 50.3 3597 5352 3857 5739
TXT-350 030124* 350 177.0 37/97.3 0.065 1.65 0.110 2.79 2.090 53.1 4124 6137 4398 6544
TXT-400 030200* 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.190 55.7 4649 6918 4937 7346
TXT-500 030647* 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.380 60.5 5680 8452 5993 8918
TXT-750 036561* 750 380.0 61/110.9 0.080 2.03 0.140 3.56 2.920 74.2 8586 12776 8969 13346
TXT-1000 036562* 1000 507.0 61/128.0 0.080 2.03 0.140 3.56 3.250 82.6 11185 16643 11613 17280

*NOTE: For aluminum armored versions, add an A (ex. 036012A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 1281-209-3857 fax www.drakausa.com

CustRef X-04
40
Draka Marine Shipboard Cables

BOSTMARINE TYPE X POWER CABLE


two conductor / unarmored & armored
14 AWG to 1000 MCM / 600V

APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001)
UL 1309/CSA 245 (1995) FIRST EDITION
2
CONSTRUCTION
1. CONDUCTOR
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated 3
VW1. Thickness as shown in tables on the reverse.
3. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-501
DRAKA MOG BOSTMARINE

DUSA_X01_1005

CustRef X-01
41
BOSTMARINE TYPE X POWER CABLE
two conductor / unarmored
14 AWG to 1000 MCM / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Conductor Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Size Type in mm in mm in mm Lbs/mft Kg/km
DXT-4 036012 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.380 9.7 81 121
DXT-6 036013 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.420 10.7 98 146
DXT-10 036050 10 5.3 7/38.5 0.030 0.76 0.045 1.14 0.470 11.9 138 205
DXT-16 036051 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.630 16.0 234 348
DXT-26 036542 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.705 17.9 280 417
DXT-41 036543 4 21.1 7/77.2 0.045 1.14 0.060 1.52 0.810 20.6 448 667
DXT-66 036544 2 33.6 7/97.4 0.045 1.14 0.080 2.03 0.970 24.6 682 1015
DXT-83 036545 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.090 27.7 835 1242
DXT-106 036546 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.180 30.0 915 1362
DXT-133 036547 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.270 32.3 1222 1818
DXT-168 036548 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.380 35.1 1491 2219
DXT-212 036549 4/0 107.2 19/105.5 0.055 1.40 0.080 2.03 1.490 37.8 1805 2686
DXT-250 036550 250 127.0 37/82.2 0.065 1.65 0.080 2.03 1.630 41.4 1945 2894
DXT-300 036551 300 152.0 37/90.0 0.065 1.65 0.110 2.79 1.810 46.0 2385 3549
DXT-350 036552 350 177.0 37/97.3 0.065 1.65 0.110 2.79 1.910 48.5 2735 4070
DXT-400 036553 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.005 50.9 3080 4584
DXT-500 036554 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.180 55.4 3755 5588
DXT-600 036555 600 304.0 61/99.2 0.080 2.03 0.110 2.79 2.405 61.1 4530 6741
DXT-750 036556 750 380.0 61/110.9 0.080 2.03 0.110 2.79 2.620 66.5 5550 8259
DXT-1000 036557 1000 507.0 61/128.0 0.080 2.03 0.140 3.56 2.995 76.1 7390 10997

two conductor / aluminum or bronze armored


14 AWG to 1000 MCM / 600V
Insulationj Jacket Armored Aluminum arm. Bronze arm.
TPC Part Conductor Size Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* AWG/MCM mm2 Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
DXT-4 036012* 14 2.1 7/24.2 0.030 0.76 0.045 1.14 0.435 11.0 104 155 159 237
DXT-6 036013* 12 3.3 7/30.5 0.030 0.76 0.045 1.14 0.475 12.1 124 185 183 272
DXT-10 036050* 10 5.3 7/38.5 0.030 0.76 0.045 1.14 0.525 13.3 167 248 233 347
DXT-16 036051* 8 8.4 7/48.6 0.045 1.14 0.060 1.52 0.685 17.4 272 405 359 534
DXT-26 036542* 6 13.3 7/61.2 0.045 1.14 0.060 1.52 0.760 19.3 322 479 419 623
DXT-41 036543* 4 21.1 7/77.2 0.045 1.14 0.060 1.52 0.865 22.0 496 738 607 903
DXT-66 036544* 2 33.6 7/97.4 0.045 1.14 0.080 2.03 1.025 26.0 739 1100 872 1298
DXT-83 036545* 1 42.4 19/66.4 0.055 1.40 0.080 2.03 1.145 29.1 899 1338 1047 1558
DXT-106 036546* 1/0 53.5 19/74.5 0.055 1.40 0.080 2.03 1.235 31.4 984 1464 1145 1704
DXT-133 036547* 2/0 67.4 19/83.7 0.055 1.40 0.080 2.03 1.325 33.7 1296 1928 1469 2632
DXT-168 036548* 3/0 85.0 19/94.0 0.055 1.40 0.080 2.03 1.435 36.4 1572 2339 1758 2616
DXT-212 036549* 4/0 107.2 19/105.5 0.055 1.40 0.080 2.03 1.545 39.2 1892 2815 2093 3114
DXT-250 036550* 250 127.0 37/82.2 0.065 1.65 0.080 2.03 1.685 42.3 2040 3036 2260 3363
DXT-300 036551* 300 152.0 37/90.0 0.065 1.65 0.110 2.79 1.865 47.4 2490 3705 2734 4068
DXT-350 036552* 350 177.0 37/97.3 0.065 1.65 0.110 2.79 1.965 49.9 2846 4235 3103 4617
DXT-400 036553* 400 203.0 37/104.0 0.065 1.65 0.110 2.79 2.060 52.3 3197 4757 3466 5157
DXT-500 036554* 500 253.0 37/116.2 0.065 1.65 0.110 2.79 2.235 56.8 3882 5776 4174 6211
DXT-600 036555* 600 304.0 61/99.2 0.080 2.03 0.110 2.79 2.460 62.5 4670 6949 4991 7427
DXT-750 036556* 750 380.0 61/110.9 0.080 2.03 0.110 2.79 2.675 67.9 5702 8485 6053 9007
DXT-1000 036557* 1000 507.0 61/128.0 0.080 2.03 0.140 3.56 3.055 77.6 7563 11254 7964 11850
*
NOTE: For aluminum armored versions, add an A (ex. 036012A). For bronze armored versions, add a B (ex. 030103B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 1281-209-3857 fax www.drakausa.com

CustRef X-02
42
Draka Marine Shipboard Cables

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
16 AWG 1.31 mm2 / 600V

APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS 3
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated 4
VW1. Thickness as shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-511
DRAKA MOG BOSTMARINE

DUSA_X13_1005

CustRef X-13
43
BOSTMARINE TYPE X SIGNAL CABLE
indiv. & overall shielded twisted pair / unarmored
16 AWG 1.31 mm2 / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP16(IS)XT-1 036646 1 7/19.2 0.025 0.64 0.045 1.14 0.32 8.1 56 83
TP16(IS-OS)XT-2 036647 2 7/19.2 0.025 0.64 0.045 1.14 0.50 12.7 104 155
TP16(IS-OS)XT-3 036648 3 7/19.2 0.025 0.64 0.060 1.52 0.56 14.2 153 228
TP16(IS-OS)XT-4 036649 4 7/19.2 0.025 0.64 0.060 1.52 0.61 15.5 190 283
TP16(IS-OS)XT-5 036650 5 7/19.2 0.025 0.64 0.060 1.52 0.67 17.0 227 338
TP16(IS-OS)XT-6 036651 6 7/19.2 0.025 0.64 0.060 1.52 0.73 18.5 265 394
TP16(IS-OS)XT-7 036652 7 7/19.2 0.025 0.64 0.060 1.52 0.73 18.5 295 439
TP16(IS-OS)XT-8 036653 8 7/19.2 0.025 0.64 0.060 1.52 0.79 20.1 332 494
TP16(IS-OS)XT-9 036654 9 7/19.2 0.025 0.64 0.080 2.03 0.89 22.6 370 551
TP16(IS-OS)XT-10 036655 10 7/19.2 0.025 0.64 0.080 2.03 0.97 24.6 449 668
TP16(IS-OS)XT-11 036656 11 7/19.2 0.025 0.64 0.080 2.03 0.99 25.1 487 724
TP16(IS-OS)XT-12 036657 12 7/19.2 0.025 0.64 0.080 2.03 0.99 25.1 516 768
TP16(IS-OS)XT-13 036658 13 7/19.2 0.025 0.64 0.080 2.03 1.04 26.4 555 826
TP16(IS-OS)XT-14 036659 14 7/19.2 0.025 0.64 0.080 2.03 1.04 26.4 585 870
TP16(IS-OS)XT-15 036660 15 7/19.2 0.025 0.64 0.080 2.03 1.10 27.9 621 924
TP16(IS-OS)XT-16 036661 16 7/19.2 0.025 0.64 0.080 2.03 1.10 27.9 654 974
TP16(IS-OS)XT-17 036662 17 7/19.2 0.025 0.64 0.080 2.03 1.15 29.2 694 1033
TP16(IS-OS)XT-18 036663 18 7/19.2 0.025 0.64 0.080 2.03 1.15 29.2 724 1078
TP16(IS-OS)XT-19 036664 19 7/19.2 0.025 0.64 0.080 2.03 1.15 29.2 754 1122
TP16(IS-OS)XT-20 036665 20 7/19.2 0.025 0.64 0.080 2.03 1.21 30.7 790 1176
TP16(IS-OS)XT-21 036666 21 7/19.2 0.025 0.64 0.080 2.03 1.21 30.7 824 1226
TP16(IS-OS)XT-22 036667 22 7/19.2 0.025 0.64 0.080 2.03 1.28 32.5 865 1287

indiv. & overall shielded twisted pair / aluminum or bronze armored


16 AWG 1.31 mm2 / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP16(IS)XT-1 036646* 1 7/19.2 0.025 0.64 0.045 1.14 0.375 9.5 76 113 122 182
TP16(IS-OS)XT-2 036647* 2 7/19.2 0.025 0.64 0.045 1.14 0.555 14.1 134 199 204 304
TP16(IS-OS)XT-3 036648* 3 7/19.2 0.025 0.64 0.060 1.52 0.615 15.6 187 278 265 394
TP16(IS-OS)XT-4 036649* 4 7/19.2 0.025 0.64 0.060 1.52 0.665 16.9 227 338 311 463
TP16(IS-OS)XT-5 036650* 5 7/19.2 0.025 0.64 0.060 1.52 0.725 18.4 267 397 360 534
TP16(IS-OS)XT-6 036651* 6 7/19.2 0.025 0.64 0.060 1.52 0.785 19.9 309 460 409 609
TP16(IS-OS)XT-7 036652* 7 7/19.2 0.025 0.64 0.060 1.52 0.785 19.9 368 548 439 653
TP16(IS-OS)XT-8 036653* 8 7/19.2 0.025 0.64 0.060 1.52 0.845 21.4 379 564 487 725
TP16(IS-OS)XT-9 036654* 9 7/19.2 0.025 0.64 0.080 2.03 0.945 24.0 423 629 544 809
TP16(IS-OS)XT-10 036655* 10 7/19.2 0.025 0.64 0.080 2.03 1.025 26.0 506 753 639 951
TP16(IS-OS)XT-11 036656* 11 7/19.2 0.025 0.64 0.080 2.03 1.045 26.5 545 811 680 1012
TP16(IS-OS)XT-12 036657* 12 7/19.2 0.025 0.64 0.080 2.03 1.045 26.5 574 854 709 1055
TP16(IS-OS)XT-13 036658* 13 7/19.2 0.025 0.64 0.080 2.03 1.095 27.8 616 917 758 1128
TP16(IS-OS)XT-14 036659* 14 7/19.2 0.025 0.64 0.080 2.03 1.095 27.8 646 961 788 1173
TP16(IS-OS)XT-15 036660* 15 7/19.2 0.025 0.64 0.080 2.03 1.155 29.3 686 1021 835 1242
TP16(IS-OS)XT-16 036661* 16 7/19.2 0.025 0.64 0.080 2.03 1.155 29.3 719 1070 868 1292
TP16(IS-OS)XT-17 036662* 17 7/19.2 0.025 0.64 0.080 2.03 1.205 24.2 762 1134 918 1366
TP16(IS-OS)XT-18 036663* 18 7/19.2 0.025 0.64 0.080 2.03 1.205 24.2 792 1178 948 1411
TP16(IS-OS)XT-19 036664* 19 7/19.2 0.025 0.64 0.080 2.03 1.205 24.2 822 1123 978 1455
TP16(IS-OS)XT-20 036665* 20 7/19.2 0.025 0.64 0.080 2.03 1.265 32.1 861 1281 1025 1525
TP16(IS-OS)XT-21 036666* 21 7/19.2 0.025 0.64 0.080 2.03 1.265 32.1 895 1332 1059 1576
TP16(IS-OS)XT-22 036667* 22 7/19.2 0.025 0.64 0.080 2.03 1.335 33.9 940 1399 1113 1656

*NOTE: For aluminum armored versions, add an A (ex. 036646A). For bronze armored versions, add a B (ex. 036646B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef X-14
44
Draka Marine Shipboard Cables

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
18 AWG 0.82 mm2 / 600V

APPLICATIONS
BOSTMARINE Type X 600 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 600
volts. Type X cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS 3
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated 4
VW1. Thickness as shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-511
DRAKA MOG BOSTMARINE

DUSA_X11_1005

CustRef X-11
45
BOSTMARINE TYPE X SIGNAL CABLE
indiv. & overall shielded twisted pair / unarmored
18 AWG 0.82 mm2 / 600V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP18(IS)XT-1 036624 1 7/15.2 0.025 0.64 0.045 1.14 0.30 7.6 46 68
TP18(IS-OS)XT-2 036625 2 7/15.2 0.025 0.64 0.045 1.14 0.45 11.4 85 126
TP18(IS-OS)XT-3 036626 3 7/15.2 0.025 0.64 0.045 1.14 0.48 12.2 109 162
TP18(IS-OS)XT-4 036627 4 7/15.2 0.025 0.64 0.060 1.52 0.59 15.0 153 228
TP18(IS-OS)XT-5 036628 5 7/15.2 0.025 0.64 0.060 1.52 0.61 15.5 182 271
TP18(IS-OS)XT-6 036629 6 7/15.2 0.025 0.64 0.060 1.52 0.66 16.8 211 314
TP18(IS-OS)XT-7 036630 7 7/15.2 0.025 0.64 0.060 1.52 0.66 16.8 232 346
TP18(IS-OS)XT-8 036631 8 7/15.2 0.025 0.64 0.060 1.52 0.72 18.3 262 390
TP18(IS-OS)XT-9 036632 9 7/15.2 0.025 0.64 0.060 1.52 0.78 19.8 290 432
TP18(IS-OS)XT-10 036633 10 7/15.2 0.025 0.64 0.080 2.03 0.89 22.6 359 534
TP18(IS-OS)XT-11 036634 11 7/15.2 0.025 0.64 0.080 2.03 0.91 23.1 346 516
TP18(IS-OS)XT-12 036635 12 7/15.2 0.025 0.64 0.080 2.03 0.91 23.1 368 548
TP18(IS-OS)XT-13 036636 13 7/15.2 0.025 0.64 0.080 2.03 0.96 24.4 438 652
TP18(IS-OS)XT-14 036637 14 7/15.2 0.025 0.64 0.080 2.03 0.96 24.4 459 684
TP18(IS-OS)XT-15 036638 15 7/15.2 0.025 0.64 0.080 2.03 1.01 25.7 490 729
TP18(IS-OS)XT-16 036639 16 7/15.2 0.025 0.64 0.080 2.03 1.01 25.7 512 762
TP18(IS-OS)XT-17 036640 17 7/15.2 0.025 0.64 0.080 2.03 1.06 26.9 543 808
TP18(IS-OS)XT-18 036641 18 7/15.2 0.025 0.64 0.080 2.03 1.06 26.9 565 840
TP18(IS-OS)XT-19 036642 19 7/15.2 0.025 0.64 0.080 2.03 1.06 26.9 586 872
TP18(IS-OS)XT-20 036643 20 7/15.2 0.025 0.64 0.080 2.03 1.11 28.2 619 921
TP18(IS-OS)XT-21 036644 21 7/15.2 0.025 0.64 0.080 2.03 1.11 28.2 639 951
TP18(IS-OS)XT-22 036645 22 7/15.2 0.025 0.64 0.080 2.03 1.16 29.5 671 998

indiv. & overall shielded twisted pair / aluminum & bronze armored
18 AWG 0.82 mm2 / 600V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP18(IS)XT-1 036624* 1 7/15.2 0.025 0.64 0.045 1.14 0.355 9.0 65 97 108 161
TP18(IS-OS)XT-2 036625* 2 7/15.2 0.025 0.64 0.045 1.14 0.505 12.8 112 167 176 262
TP18(IS-OS)XT-3 036626* 3 7/15.2 0.025 0.64 0.045 1.14 0.535 13.6 138 205 206 307
TP18(IS-OS)XT-4 036627* 4 7/15.2 0.025 0.64 0.060 1.52 0.645 16.4 188 280 271 403
TP18(IS-OS)XT-5 036628* 5 7/15.2 0.025 0.64 0.060 1.52 0.665 16.9 219 326 303 451
TP18(IS-OS)XT-6 036629* 6 7/15.2 0.025 0.64 0.060 1.52 0.715 18.2 251 373 342 509
TP18(IS-OS)XT-7 036630* 7 7/15.2 0.025 0.64 0.060 1.52 0.715 18.2 272 405 363 540
TP18(IS-OS)XT-8 036631* 8 7/15.2 0.025 0.64 0.060 1.52 0.775 19.7 305 454 404 601
TP18(IS-OS)XT-9 036632* 9 7/15.2 0.025 0.64 0.060 1.52 0.835 21.2 336 500 444 661
TP18(IS-OS)XT-10 036633* 10 7/15.2 0.025 0.64 0.080 2.03 0.925 23.5 364 542 478 711
TP18(IS-OS)XT-11 036634* 11 7/15.2 0.025 0.64 0.080 2.03 0.965 24.5 393 585 512 762
TP18(IS-OS)XT-12 036635* 12 7/15.2 0.025 0.64 0.080 2.03 0.965 24.5 422 628 546 812
TP18(IS-OS)XT-13 036636* 13 7/15.2 0.025 0.64 0.080 2.03 1.015 25.8 495 737 626 931
TP18(IS-OS)XT-14 036637* 14 7/15.2 0.025 0.64 0.080 2.03 1.015 25.8 516 768 647 963
TP18(IS-OS)XT-15 036638* 15 7/15.2 0.025 0.64 0.080 2.03 1.065 27.1 550 818 687 1022
TP18(IS-OS)XT-16 036639* 16 7/15.2 0.025 0.64 0.080 2.03 1.065 27.1 572 851 709 1055
TP18(IS-OS)XT-17 036640* 17 7/15.2 0.025 0.64 0.080 2.03 1.115 28.3 605 900 750 1116
TP18(IS-OS)XT-18 036641* 18 7/15.2 0.025 0.64 0.080 2.03 1.115 28.3 627 933 772 1149
TP18(IS-OS)XT-19 036642* 19 7/15.2 0.025 0.64 0.080 2.03 1.115 28.3 648 964 793 1180
TP18(IS-OS)XT-20 036643* 20 7/15.2 0.025 0.64 0.080 2.03 1.165 29.6 684 1018 835 1242
TP18(IS-OS)XT-21 036644* 21 7/15.2 0.025 0.64 0.080 2.03 1.165 29.6 704 1048 855 1272
TP18(IS-OS)XT-22 036645* 22 7/15.2 0.025 0.64 0.080 2.03 1.215 30.9 739 1100 897 1335

*NOTE: For aluminum armored versions, add an A (ex. 036624A). For bronze armored versions, add a B (ex. 036624B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef X-12
46
Draka Marine Shipboard Cables

BOSTMARINE TYPE X SIGNAL CABLE


indiv. & overall shielded twisted pair / unarmored & armored
20 AWG 0.52 mm2 / 300V

APPLICATIONS
BOSTMARINE Type X 300 volt cables are suitable for use in commercial marine applica-
tions where flame retardant cables having excellent physical and electrical properties are
required. The insulation system has a continuous operating temperature of 90C.
These cables meet all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309 and
the Flame Test in IEC 60332-3, Category A. They are listed by ETL, a nationally recognized
testing laboratory, per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245 for 300
volts. Type X cables are Type Approved by ABS and LRS. 1
Aluminum and bronze armored versions are available.
Optional outer PVC sheath available upon request.

FEATURES
IEEE STANDARD 45 (1998)
IEEE STANDARD 1580 (2001) 2
UL 1309/CSA 245 (1995) FIRST EDITION

CONSTRUCTION
1. CONDUCTORS 3
Soft annealed bare copper per ASTM B 3 and B 8, stranded as shown in table on
reverse.
2. INSULATION
Bostmarine Type X thermosetting cross-linked polyethylene meeting specifications IEEE
45 (1998), IEEE-1580 (2001) and UL 1309/CSA 245. Insulated conductors are rated 4
VW1. Thickness as shown in tables on the reverse.
3. PAIR SHIELD
Aluminum / polyester tape with tinned copper drain wire to provide 100% coverage
over the twisted pair, covered with a polyester tape.
4. JACKET
Flame-retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core
(covered with a polyester separator tape) and complies with Type T polyvinyl chloride
as required in IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.

RATINGS
Meets all test requirements of IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245
(1995) First Edition and the Flame Test in IEC 60332-3, Category A.

APPROVALS
ETL/Intertek Testing Services Listed as Marine Shipboard Cable in accordance with
IEEE 45 (1998), IEEE 1580 (2001), UL 1309/CSA 245 and the performance requirements
of IEC 60092-3 for 0.6/1 kV.
American Bureau of Shipping Type Approval Certificate No. 04-PA496819-X.
Lloyds Registry of Shipping Type Approval Certificate No. 96/60031(E2).
Transport Canada Approved cables are available.
Manufactured to Draka Cableteq USA Specifying Standard J-511
DRAKA MOG BOSTMARINE

DUSA_X09_1005

CustRef X-09
47
BOSTMARINE TYPE X SIGNAL CABLE
indiv. & overall shielded twisted pair / unarmored
20 AWG 0.52 mm2 / 300V
Insulation Jacket Cable Diameter Cable Weight
TPC Part Number of Stranding Thickness Thickness (nominal) (approximate)
Cable Type Number Pairs Type in mm in mm in mm Lbs/mft Kg/km
TP20(IS)XT-1 036602 1 7/12.1 0.025 0.64 0.045 1.14 0.28 7.1 36 54
TP20(IS-OS)XT-2 036603 2 7/12.1 0.025 0.64 0.045 1.14 0.41 10.4 64 95
TP20(IS-OS)XT-3 036604 3 7/12.1 0.025 0.64 0.045 1.14 0.43 10.9 80 119
TP20(IS-OS)XT-4 036605 4 7/12.1 0.025 0.64 0.045 1.14 0.48 12.2 97 144
TP20(IS-OS)XT-5 036606 5 7/12.1 0.025 0.64 0.060 1.52 0.55 14.0 132 196
TP20(IS-OS)XT-6 036607 6 7/12.1 0.025 0.64 0.060 1.52 0.60 15.2 152 226
TP20(IS-OS)XT-7 036608 7 7/12.1 0.025 0.64 0.060 1.52 0.60 15.2 164 244
TP20(IS-OS)XT-8 036609 8 7/12.1 0.025 0.64 0.060 1.52 0.65 16.5 185 275
TP20(IS-OS)XT-9 036610 9 7/12.1 0.025 0.64 0.060 1.52 0.69 17.5 204 303
TP20(IS-OS)XT-10 036611 10 7/12.1 0.025 0.64 0.060 1.52 0.75 19.1 226 336
TP20(IS-OS)XT-11 036612 11 7/12.1 0.025 0.64 0.060 1.52 0.78 19.8 242 360
TP20(IS-OS)XT-12 036613 12 7/12.1 0.025 0.64 0.060 1.52 0.78 19.8 256 381
TP20(IS-OS)XT-13 036614 13 7/12.1 0.025 0.64 0.060 1.52 0.82 20.8 275 409
TP20(IS-OS)XT-14 036615 14 7/12.1 0.025 0.64 0.060 1.52 0.82 20.8 289 430
TP20(IS-OS)XT-15 036616 15 7/12.1 0.025 0.64 0.080 2.03 0.90 22.9 346 515
TP20(IS-OS)XT-16 036617 16 7/12.1 0.025 0.64 0.080 2.03 0.90 22.9 359 534
TP20(IS-OS)XT-17 036618 17 7/12.1 0.025 0.64 0.080 2.03 0.95 24.1 381 566
TP20(IS-OS)XT-18 036619 18 7/12.1 0.025 0.64 0.080 2.03 0.95 24.1 395 587
TP20(IS-OS)XT-19 036620 19 7/12.1 0.025 0.64 0.080 2.03 0.95 24.1 408 608
TP20(IS-OS)XT-20 036621 20 7/12.1 0.025 0.64 0.080 2.03 0.99 25.1 429 638
TP20(IS-OS)XT-21 036622 21 7/12.1 0.025 0.64 0.080 2.03 0.99 25.1 444 661
TP20(IS-OS)XT-22 036623 22 7/12.1 0.025 0.64 0.080 2.03 1.04 26.4 466 694

indiv. & overall shielded twisted pair / aluminum or bronze armored


20 AWG 0.52 mm2 / 300V
Insulation Jacket Armored Aluminum arm. Bronze arm.
TPC Part Number of Stranding Thickness Thickness Cable Diameter Cable Weight Cable Weight
Cable Type Number* Pairs Type in mm in mm in mm Lbs/mft Kg/km Lbs/mft Kg/km
TP20(IS)XT-1 036602* 1 7/12.1 0.025 0.64 0.045 1.14 0.335 8.5 54 80 95 141
TP20(IS-OS)XT-2 036603* 2 7/12.1 0.025 0.64 0.045 1.14 0.465 11.8 89 132 147 219
TP20(IS-OS)XT-3 036604* 3 7/12.1 0.025 0.64 0.045 1.14 0.485 12.3 106 158 167 248
TP20(IS-OS)XT-4 036605* 4 7/12.1 0.025 0.64 0.045 1.14 0.535 13.6 126 187 194 289
TP20(IS-OS)XT-5 036606* 5 7/12.1 0.025 0.64 0.060 1.52 0.605 15.4 165 246 242 360
TP20(IS-OS)XT-6 036607* 6 7/12.1 0.025 0.64 0.060 1.52 0.655 16.6 188 280 271 403
TP20(IS-OS)XT-7 036608* 7 7/12.1 0.025 0.64 0.060 1.52 0.655 16.6 200 298 283 421
TP20(IS-OS)XT-8 036609* 8 7/12.1 0.025 0.64 0.060 1.52 0.705 17.9 224 333 314 467
TP20(IS-OS)XT-9 036610* 9 7/12.1 0.025 0.64 0.060 1.52 0.745 18.9 245 365 340 506
TP20(IS-OS)XT-10 036611* 10 7/12.1 0.025 0.64 0.060 1.52 0.805 20.4 271 403 374 556
TP20(IS-OS)XT-11 036612* 11 7/12.1 0.025 0.64 0.060 1.52 0.835 21.2 288 429 396 589
TP20(IS-OS)XT-12 036613* 12 7/12.1 0.025 0.64 0.060 1.52 0.835 21.2 302 449 410 610
TP20(IS-OS)XT-13 036614* 13 7/12.1 0.025 0.64 0.060 1.52 0.875 22.2 324 482 436 649
TP20(IS-OS)XT-14 036615* 14 7/12.1 0.025 0.64 0.060 1.52 0.875 22.2 338 503 450 670
TP20(IS-OS)XT-15 036616* 15 7/12.1 0.025 0.64 0.080 2.03 0.955 24.3 399 594 522 777
TP20(IS-OS)XT-16 036617* 16 7/12.1 0.025 0.64 0.080 2.03 0.955 24.3 412 613 535 796
TP20(IS-OS)XT-17 036618* 17 7/12.1 0.025 0.64 0.080 2.03 1.005 25.5 437 650 567 844
TP20(IS-OS)XT-18 036619* 18 7/12.1 0.025 0.64 0.080 2.03 1.005 25.5 451 671 584 869
TP20(IS-OS)XT-19 036620* 19 7/12.1 0.025 0.64 0.080 2.03 1.005 25.5 464 690 594 884
TP20(IS-OS)XT-20 036621* 20 7/12.1 0.025 0.64 0.080 2.03 1.045 26.5 487 725 622 926
TP20(IS-OS)XT-21 036622* 21 7/12.1 0.025 0.64 0.080 2.03 1.045 26.5 502 747 637 948
TP20(IS-OS)XT-22 036623* 22 7/12.1 0.025 0.64 0.080 2.03 1.095 27.8 527 784 669 995

*NOTE: For aluminum armored versions, add an A (ex. 036602A). For bronze armored versions, add a B (ex. 036602B).
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information.
This information is not meant to replace the information in the appropriate and applicable standard or code.

Draka USA Distribution 1610 Greens Road / Suite 200 Houston, TX 77032 281-209-1070 888-354-2225 281-209-3857 fax www.drakausa.com

CustRef X-10
48
Bostrig Type P
0807
Page 17 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed
TYPE P CONTROL CABLE
600V or 0.6/1kV
12 & 10 AWG
1 2 3 4 5

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush
03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225.
Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating
No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J105
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.
Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
4. Armor Braided bronze in accordance with IEEE 1580 (2001).
5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
49
www.DrakaMOG.com
Bostrig Type P
0807
Page 18 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV

multi-conductor / armored and sheathed


12 & 10 AWG / 600V or 0.6/1kV
12 AWG 3.08 mm2
Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C12PNBS-2 026300 2 .030 0.76 .060 1.5 .605 15.4 250 372
C12PNBS-3 026301 3 .030 0.76 .060 1.5 .620 15.8 285 424
C12PNBS-4 026302 4 .030 0.76 .060 1.5 .665 16.9 325 484
C12PNBS-5 026303 5 .030 0.76 .060 1.5 .710 18.0 370 551
C12PNBS-6 026304 6 .030 0.76 .060 1.5 .750 19.1 415 618
C12PNBS-7 026305 7 .030 0.76 .060 1.5 .750 19.1 435 647
C12PNBS-8 026306 8 .030 0.76 .060 1.5 .800 20.3 485 722
C12PNBS-10 026307 10 .030 0.76 .080 2.0 .940 23.9 620 923
C12PNBS-12 026308 12 .030 0.76 .080 2.0 .965 24.5 680 1012
C12PNBS-16 026309 16 .030 0.76 .080 2.0 1.085 27.6 870 1295
C12PNBS-20 026310 20 .030 0.76 .080 2.0 1.175 29.9 1020 1518
C12PNBS-24 026311 24 .030 0.76 .080 2.0 1.280 32.5 1180 1756
C12PNBS-30 026312 30 .030 0.76 .080 2.0 1.340 34.0 1370 2039
C12PNBS-37 026313 37 .030 0.76 .110 2.8 1.490 37.9 1685 2508
C12PNBS-44 026314 44 .030 0.76 .110 2.8 1.640 41.7 1955 2909
C12PNBS-60 026315 60 .030 0.76 .125 3.2 1.875 47.6 2630 3914
C12PNBS-91 026316 91 .030 0.76 .125 3.2 2.180 55.4 3670 5462

10 AWG 5.53 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C10PNBS-2 026317 2 .030 0.76 .060 1.5 .670 17.0 315 469
C10PNBS-3 026318 3 .030 0.76 .060 1.5 .695 17.7 370 551
C10PNBS-4 026319 4 .030 0.76 .060 1.5 .750 19.1 430 640
C10PNBS-5 026320 5 .030 0.76 .060 1.5 .820 20.8 500 744
C10PNBS-6 026321 6 .030 0.76 .080 2.0 .895 22.7 600 893
C10PNBS-7 026322 7 .030 0.76 .080 2.0 .895 22.7 640 952
C10PNBS-8 026323 8 .030 0.76 .080 2.0 .950 24.1 710 1057
C100PNBS-10 026324 10 .030 0.76 .080 2.0 1.112 28.5 910 1354

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-
ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3 Table 4
Three Conductor Cable, four Conductor Cables with more than four Current Carrying Conductors
Cables with three Current Carrying
No of Conductors Derating Factor from 3
Conductors 45C Ambient
Conductor Ampacity
Conductor Size 4-6 0.8
Gauge CMA mm2 95C 100C 110C 7-9 0.7
12 6,503 3.30 26 31 33
10-20 0.5
10 10,908 5.53 37 41 44
21-30 0.45
31-40 0.40
41-60 0.35
61 and greater 0.30
50
www.DrakaMOG.com
Bostrig Type P
0807
Page 41 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored
TYPE P CONTROL CABLE
600V or 0.6/1kV
12 & 10 AWG
1 2 3

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates
design. They satisfy Transport Canadas cold bend at
No. 95/00161(E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored and
sheathed version. Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

51
www.DrakaMOG.com
Bostrig Type P
0807
Page 42 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV

multi-conductor / unarmored
12 & 10 AWG / 600V or 0.6/1kV
12 AWG 3.08 mm2
Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C12PN-2 026224 2 .030 0.76 .060 1.5 .425 10.8 100 149
C12PN-3 026225 3 .030 0.76 .060 1.5 .440 11.2 135 201
C12PN-4 026226 4 .030 0.76 .060 1.5 .475 12.1 155 231
C12PN-5 026227 5 .030 0.76 .060 1.5 .525 13.3 190 283
C12PN-6 026228 6 .030 0.76 .060 1.5 .570 14.5 220 327
C12PN-7 026229 7 .030 0.76 .060 1.5 .570 14.5 245 365
C12PN-8 026230 8 .030 0.76 .060 1.5 .620 15.6 280 417
C12PN-10 026231 10 .030 0.76 .060 1.5 .720 18.3 355 528
C12PN-12 026232 12 .030 0.76 .060 1.5 .745 18.9 400 595
C12PN-16 026233 16 .030 0.76 .080 2.0 .865 22.0 550 818
C12PN-20 026234 20 .030 0.76 .080 2.0 .955 24.3 680 1012
C12PN-24 026235 24 .030 0.76 .080 2.0 1.060 26.9 795 1183
C12PN-30 026236 30 .030 0.76 .080 2.0 1.120 28.5 955 1421
C12PN-37 026237 37 .030 0.76 .080 2.0 1.210 30.7 1140 1697
C12PN-44 026238 44 .030 0.76 .080 2.0 1.355 34.4 1390 2069
C12PN-60 026239 60 .030 0.76 .110 2.8 1.565 39.8 1880 2798
C12PN-91 026240 91 .030 0.76 .125 3.2 1.880 47.8 2800 4167

10 AWG 5.53 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C10PN-2 026241 2 .030 0.76 .060 1.5 .490 12.5 115 171
C10PN-3 026242 3 .030 0.76 .060 1.5 .520 13.2 200 298
C10PN-4 026243 4 .030 0.76 .060 1.5 .565 14.4 240 357
C10PN-5 026244 5 .030 0.76 .060 1.5 .620 15.8 295 439
C10PN-6 026245 6 .030 0.76 .060 1.5 .675 17.2 350 521
C10PN-7 026246 7 .030 0.76 .060 1.5 .675 17.2 390 580
C10PN-8 026247 8 .030 0.76 .060 1.5 .730 18.5 445 662
C10PN-10 026248 10 .030 0.76 .080 2.0 .895 22.7 590 878

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-
ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.
Table 3 Table 4
Three Conductor Cable, four Conductor Cables with more than four Current Carrying Conductors
Cables with three Current Carrying
No of Conductors Derating Factor from 3
Conductors 45C Ambient
Conductor Ampacity
Conductor Size 4-6 0.8
Gauge CMA mm2 95C 100C 110C 7-9 0.7
12 6,503 3.30 26 31 33
10-20 0.5
10 10,908 5.53 37 41 44
21-30 0.45
31-40 0.40
41-60 0.35
61 and greater 0.30

52
www.DrakaMOG.com
Bostrig Type P
0807
Page 39 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored
TYPE P CONTROL CABLE
600V or 0.6/1kV
14 AWG
1 2 3

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates
design. They satisfy Transport Canadas cold bend at
No. 95/00161(E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored and
sheathed version. Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on oppposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

53
www.DrakaMOG.com
Bostrig Type P
0807
Page 40 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV

multi-conductor / unarmored
14 AWG / 600V or 0.6/1kV 1.94 mm2

Insulation Sheath Cable Diameter Cable Weight


Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C14PN-2 026207 2 .030 0.76 .060 1.5 .380 6.7 77 115
C14PN-3 026208 3 .030 0.76 .060 1.5 .390 9.9 100 149
C14PN-4 026209 4 .030 0.76 .060 1.5 .430 10.9 115 171
C14PN-5 026210 5 .030 0.76 .060 1.5 .475 12.1 147 218
C14PN-6 026211 6 .030 0.76 .060 1.5 .515 13.1 165 246
C14PN-7 026212 7 .030 0.76 .060 1.5 .515 13.1 180 268
C14PN-8 026213 8 .030 0.76 .060 1.5 .560 14.2 210 313
C14PN-10 026214 10 .030 0.76 .060 1.5 .650 16.5 260 387
C14PN-12 026215 12 .030 0.76 .060 1.5 .670 17.0 290 432
C14PN-16 026216 16 .030 0.76 .060 1.5 .740 18.8 375 558
C14PN-20 026217 20 .030 0.76 .060 1.5 .820 20.8 495 737
C14PN-24 026218 24 .030 0.76 .060 1.5 .950 24.1 585 871
C14PN-30 026219 30 .030 0.76 .080 2.0 1.005 25.5 695 1034
C14PN-37 026220 37 .030 0.76 .080 2.0 1.080 27.4 850 1265
C14PN-44 026297 44 .030 0.76 .080 2.0 1.215 30.9 990 1473
C14PN-60 026298 60 .030 0.76 .080 2.0 1.345 34.2 1300 1935
C14PN-91 026299 91 .030 0.76 .080 2.0 1.650 41.9 1980 2947

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-
ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3 Table 4
Three Conductor Cable, four Conductor Cables with more than four Current Carrying Conductors
Cables with three Current Carrying
No of Conductors Derating Factor from 3
Conductors 45C Ambient
Conductor Ampacity
Conductor Size 4-6 0.8
Gauge CMA mm2 95C 100C 110C 7-9 0.7
14 4,106 2.08 20 25 27
10-20 0.5
21-30 0.45
31-40 0.40
41-60 0.35
61 and greater 0.30

54
www.DrakaMOG.com
Bostrig Type P
0807
Page 15 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed
TYPE P CONTROL CABLE
600V or 0.6/1kV
14 AWG
1 2 3 4 5

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush
03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225.
Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating
No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J105
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.
Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
4. Armor Braided bronze in accordance with IEEE 1580 (2001).
5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
55
www.DrakaMOG.com
Bostrig Type P
0807
Page 16 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV

multi-conductor / armored and sheathed


14 AWG / 600V or 0.6/1kV 1.94 mm2

Insulation Sheath Cable Diameter Cable Weight


Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C14PNBS-2 026283 2 .030 0.76 .060 1.5 .560 14.2 205 305
C14PNBS-3 026284 3 .030 0.76 .060 1.5 .575 14.6 240 357
C14PNBS-4 026285 4 .030 0.76 .060 1.5 .620 15.8 275 409
C14PNBS-5 026286 5 .030 0.76 .060 1.5 .660 16.8 305 454
C14PNBS-6 026287 6 .030 0.76 .060 1.5 .700 17.8 340 506
C14PNBS-7 026288 7 .030 0.76 .060 1.5 .700 17.8 355 528
C14PNBS-8 026289 8 .030 0.76 .060 1.5 .740 18.8 395 588
C14PNBS-10 026290 10 .030 0.76 .060 1.5 .860 21.8 500 744
C14PNBS-12 026291 12 .030 0.76 .060 1.5 .890 22.6 550 818
C14PNBS-16 026292 16 .030 0.76 .060 1.5 .960 24.4 655 975
C14PNBS-20 026293 20 .030 0.76 .060 1.5 1.040 26.4 770 1146
C14PNBS-24 026294 24 .030 0.76 .080 2.0 1.170 29.7 930 1384
C14PNBS-30 026295 30 .030 0.76 .080 2.0 1.225 31.1 1060 1577
C14PNBS-37 026296 37 .030 0.76 .080 2.0 1.305 33.2 1240 1845
C14PNBS-44 026297 44 .030 0.76 .110 2.8 1.495 38.0 1510 2247
C14PNBS-60 026298 60 .030 0.76 .110 2.8 1.625 41.3 1880 2298
C14PNBS-91 026299 91 .030 0.76 .115 2.9 1.950 49.5 2750 4093

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-
ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3 Table 4
Three Conductor Cable, four Conductor Cables with 4 or moreCurrent Carrying Conductors
Cables with three Current Carrying
No of Conductors Derating Factor from 3
Conductors 45C Ambient
Conductor Ampacity
Conductor Size 4-6 0.8
Gauge CMA mm2 95C 100C 110C 7-9 0.7
14 4,106 2.08 20 25 27
10-20 0.5
21-30 0.45
31-40 0.40
41-60 0.35
61 and greater 0.30

56
www.DrakaMOG.com
Bostrig Type P
0807
Page 37 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored
TYPE P CONTROL CABLE
600V or 0.6/1kV
16 AWG
1 2 3

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates
design. They satisfy Transport Canadas cold bend at
No. 95/00161(E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored and
sheathed version. Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

57
www.DrakaMOG.com
Bostrig Type P
0807
Page 38 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV

multi-conductor / unarmored
16 AWG / 600V or 0.6/1kV 1.23 mm2

Insulation Sheath Cable Diameter Cable Weight


Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C16PN-2 026190 2 .030 0.76 .060 1.5 .355 9.0 65 97
C16PN-3 026191 3 .030 0.76 .060 1.5 .370 9.4 80 119
C16PN-4 026192 4 .030 0.76 .060 1.5 .400 10.2 95 141
C16PN-5 026193 5 .030 0.76 .060 1.5 .440 11.2 115 171
C16PN-6 026194 6 .030 0.76 .060 1.5 .475 12.1 135 201
C16PN-7 026195 7 .030 0.76 .060 1.5 .475 12.1 145 216
C16PN-8 026196 8 .030 0.76 .060 1.5 .540 13.7 160 238
C16PN-10 026197 10 .030 0.76 .060 1.5 .595 15.1 200 298
C16PN-12 026198 12 .030 0.76 .060 1.5 .610 15.5 225 335
C16PN-16 026199 16 .030 0.76 .060 1.5 .675 17.2 285 424
C16PN-20 026200 20 .030 0.76 .060 1.5 .745 18.9 350 521
C16PN-24 026201 24 .030 0.76 .060 1.5 .840 21.3 440 655
C16PN-30 026202 30 .030 0.76 .080 2.0 .915 23.2 520 774
C16PN-37 026203 37 .030 0.76 .080 2.0 .985 25.0 625 930
C16PN-44 026204 44 .030 0.76 .080 2.0 1.100 27.9 735 1094
C16PN-60 026205 60 .030 0.76 .080 2.0 1.220 31.0 960 1429
C16PN-91 026206 91 .030 0.76 .080 2.0 1.480 37.6 1470 2188

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-
ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3 Table 4
Three Conductor Cable, four Conductor Cables with more than four Current Carrying Conductors
Cables with three Current Carrying
No of Conductors Derating Factor from 3
Conductors 45C Ambient
Conductor Ampacity
Conductor Size 4-6 0.8
Gauge CMA mm2 95C 100C 110C 7-9 0.7
16 2,061 1.32 16 17 18
10-20 0.5
21-30 0.45
31-40 0.40
41-60 0.35
61 and greater 0.30

58
www.DrakaMOG.com
Bostrig Type P
0807
Page 13 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed
TYPE P CONTROL CABLE
600V or 0.6/1kV
16 AWG
1 2 3 4 5

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush
03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225.
Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating
No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J105
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.
Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
4. Armor Braided bronze in accordance with IEEE 1580 (2001).
5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
59
www.DrakaMOG.com
Bostrig Type P
0807
Page 14 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV

multi-conductor / armored and sheathed


16 AWG / 600V or 0.6/1kV 1.23 mm2

Insulation Sheath Cable Diameter Cable Weight


Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C16PNBS-2 026266 2 .030 0.76 .060 1.5 .535 13.6 190 283
C16PNBS-3 026267 3 .030 0.76 .060 1.5 .545 13.8 205 305
C16PNBS-4 0262668 4 .030 0.76 .060 1.5 .590 15.0 235 350
C16PNBS-5 026269 5 .030 0.76 .060 1.5 .620 15.8 265 394
C16PNBS-6 026270 6 .030 0.76 .060 1.5 .655 16.6 295 439
C16PNBS-7 026271 7 .030 0.76 .060 1.5 .655 16.6 300 446
C16PNBS-8 026272 8 .030 0.76 .060 1.5 .720 18.3 340 506
C16PNBS-10 026273 10 .030 0.76 .060 1.5 .775 19.7 400 595
C16PNBS-12 026274 12 .030 0.76 .060 1.5 .790 20.1 430 640
C16PNBS-16 026275 16 .030 0.76 .080 2.0 .895 22.7 545 811
C16PNBS-20 026276 20 .030 0.76 .080 2.0 .965 24.5 635 945
C16PNBS-24 026277 24 .030 0.76 .080 2.0 1.050 26.7 755 1124
C16PNBS-30 026278 30 .030 0.76 .080 2.0 1.135 28.8 865 1287
C16PNBS-37 026279 37 .030 0.76 .080 2.0 1.205 30.6 995 1480
C16PNBS-44 026280 44 .030 0.76 .080 2.0 1.320 33.5 1125 1674
C16PNBS-60 026281 60 .030 0.76 .110 2.8 1.500 38.1 1495 2225
C16PNBS-91 026282 91 .030 0.76 .110 2.8 1.770 45.0 2100 3125

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-
ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3 Table 4
Three Conductor Cable, four Conductor Cables with 4 or more Current Carrying Conductors
Cables with three Current Carrying
No of Conductors Derating Factor from 3
Conductors 45C Ambient
Conductor Ampacity
Conductor Size 4-6 0.8
Gauge CMA mm2 95C 100C 110C 7-9 0.7
16 2,601 1.32 16 17 18
10-20 0.5
21-30 0.45
31-40 0.40
41-60 0.35
61 and greater 0.30

60
www.DrakaMOG.com
Bostrig Type P
0807
Page 35 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / unarmored
TYPE P CONTROL CABLE
600V or 0.6/1kV
18 AWG
1 2 3

Approvals
Applications
ETL/Intertek Testing Services Listed as Marine Shipboard
BostrigTM Type P Marine and Offshore Cable is
Cable in accordance with IEEE 45 (1998), IEEE 1580
primarily designed for power, control, signal and
(2001), UL 1309/CSA245 and the performance
instrumentation applications for offshore, land rigs,
requirements of IEC 60092-3.
marine vessels and oil and gas drilling rigs.
Det Norske Veritas Type Approval Certificates E8792,
Bostrig cables have excellent resistance to oil, abrasion,
E8793, E8794, E8795 and E8796.
moisture, sunlight and ester-based mud (Type P-MR).
American Bureau of Shipping Approval Certificate
The standard insulation has a continuous operating
03-HS347018C/3-PDA.
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Lloyds Registry of Shipping Approval Certificates
design. They satisfy Transport Canadas cold bend at No. 95/00161(E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3). Transport Canada Approved AMS400-20-2
This product is readily available in an armored and Manufactured to BIW Specifying Standard J105
sheathed version.

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

61
www.DrakaMOG.com
Bostrig Type P
0807
Page 36 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV

multi-conductor / unarmored
18 AWG / 600V or 0.6/1kV 0.96 mm2

Insulation Jacket Cable Diameter Cable Weight


Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C18PN-2 026173 2 .030 0.76 .060 1.5 .340 8.6 55 82
C18PN-3 026174 3 .030 0.76 .060 1.5 .360 9.1 70 104
C18PN-4 026175 4 .030 0.76 .060 1.5 .390 9.9 85 127
C18PN-5 026176 5 .030 0.76 .060 1.5 .425 10.8 100 149
C18PN-6 026177 6 .030 0.76 .060 1.5 .460 11.7 120 179
C18PN-7 026178 7 .030 0.76 .060 1.5 .460 11.7 130 193
C18PN-8 026179 8 .030 0.76 .060 1.5 .490 12.5 140 208
C18PN-10 026180 10 .030 0.76 .060 1.5 .570 14.5 175 260
C18PN-12 026181 12 .030 0.76 .060 1.5 .585 14.9 195 290
C18PN-16 026182 16 .030 0.76 .060 1.5 .660 16.8 250 372
C18PN-20 026183 20 .030 0.76 .060 1.5 .715 18.2 305 454
C18PN-24 026184 24 .030 0.76 .060 1.5 .790 20.1 355 528
C18PN-30 026185 30 .030 0.76 .080 2.0 .875 22.2 455 677
C18PN-37 026186 37 .030 0.76 .080 2.0 .940 23.9 545 811
C18PN-44 026187 44 .030 0.76 .080 2.0 1.055 26.8 640 952
C18PN-60 026188 60 .030 0.76 .080 2.0 1.165 29.6 835 1243
C18PN-91 026189 91 .030 0.76 .080 2.0 1.390 35.3 1220 1816

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-
ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3 Table 4
Three Conductor Cable, four Conductor Cables with more than four Current Carrying Conductors
Cables with three Current Carrying
No of Conductors Derating Factor from 3
Conductors 45C Ambient
Conductor Ampacity
Conductor Size 4-6 0.8
Gauge CMA mm2 95C 100C 110C 7-9 0.7
18 1,620 0.82 11 12 13
10-20 0.5
21-30 0.45
31-40 0.40
41-60 0.35
61 and greater 0.30

62
www.DrakaMOG.com
Bostrig Type P
0807
Page 11 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Multi-conductor / armored and sheathed
TYPE P CONTROL CABLE
600V or 0.6/1kV
18 AWG
1 2 3 4 5

Approvals
Applications
ETL/Intertek Testing Services Listed as Marine Shipboard
BostrigTM Type P Marine and Offshore Cable is
Cable in accordance with IEEE 45 (1998), IEEE 1580
primarily designed for power, control, signal and
(2001), UL 1309/CSA245 and the performance
instrumentation applications for offshore, land rigs,
requirements of IEC 60092-3.
marine vessels and oil and gas drilling rigs.
Det Norske Veritas Type Approval Certificates E8792,
Bostrig cables have excellent resistance to oil, abrasion,
E8793, E8794, E8795 and E8796.
moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush 03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225. Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity Transport Canada Approved AMS400-20-2
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J105

-40C and cold impact at -35C (CSA C 22.2 No. 0.3).


This product is readily available in an unarmored version.
Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
4. Armor Braided bronze in accordance with IEEE 1580 (2001).
5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
63
www.DrakaMOG.com
Bostrig Type P
0807
Page 12 of 62

BOSTRIG TYPE P CONTROL CABLE 600V or 0.6/1kV

multi-conductor / armored and sheathed


18 AWG / 600V or 0.6/1kV 0.96 mm2

Insulation Sheath Cable Diameter Cable Weight


Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C18PNBS-2 026249 2 .030 0.76 .060 1.5 .515 13.1 180 268
C18PNBS-3 026250 3 .030 0.76 .060 1.5 .540 13.7 200 298
C18PNBS-4 026251 4 .030 0.76 .060 1.5 .575 14.6 225 335
C18PNBS-5 026252 5 .030 0.76 .060 1.5 .605 15.4 250 372
C18PNBS-6 026253 6 .030 0.76 .060 1.5 .640 16.3 275 409
C18PNBS-7 026254 7 .030 0.76 .060 1.5 .640 16.3 285 424
C18PNBS-8 026255 8 .030 0.76 .060 1.5 .670 17.1 310 461
C18PNBS-10 026256 10 .030 0.76 .060 1.5 .750 19.1 365 543
C18PNBS-12 026257 12 .030 0.76 .060 1.5 .765 19.1 365 543
C18PNBS-16 026258 16 .030 0.76 .080 2.0 .885 22.5 500 744
C18PNBS-20 026259 20 .030 0.76 .080 2.0 .935 23.8 580 863
C18PNBS-24 026260 24 .030 0.76 .080 2.0 1.010 25.7 655 975
C18PNBS-30 026261 30 .030 0.76 .080 2.0 1.100 27.9 790 1176
C18PNBS-37 026262 37 .030 0.76 .080 2.0 1.165 29.6 900 1339
C18PNBS-44 026263 44 .030 0.76 .080 2.0 1.275 32.4 1035 1540
C18PNBS-60 026264 60 .030 0.76 .110 2.8 1.445 36.7 1355 2016
C18PNBS-91 026265 91 .030 0.76 .110 2.8 1.650 41.9 1860 2768

Control cables are not intended for continuous current carrying applications. The current limit on these cables should be for providing control functions through
relays and switching devices. The maximum current for any one conductor should not exceed the value Table 3 for three conductor cables. The average of all con-
ductors should not exceed the limit based on the total number of conductors in the cable taken from Table 4 multiplied by the ampacity from Table 3.
This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Table 3 Table 4
Three Conductor Cable, four Conductor Cables with more than four Current Carrying Conductors
Cables with three Current Carrying
No of Conductors Derating Factor from 3
Conductors 45C Ambient
Conductor Ampacity
Conductor Size 4-6 0.8
Gauge CMA mm2 95C 100C 110C 7-9 0.7
18 1,620 0.82 11 12 13
10-20 0.5
21-30 0.45
31-40 0.40
41-60 0.35
61 and greater 0.30

64
www.DrakaMOG.com
Bostrig Type P
0807
Page 61 of 62

BOSTRIG TYPE P-MR POWER CABLE


Single conductor / armored & sheathed
and unarmored ester-based mud resistant
TYPE P-MR POWER CABLE
2000V
1 2 3 4
4/0 AWG TO 1111 MCM

Applications Approvals
BostrigTM Type P Mud Resistant Cable is primarily ETL/Intertek Testing Services Listed as Marine Shipboard
designed for power, control, signal and instrumentation Cable in accordance with IEEE 45 (1998), IEEE 1580
applications for offshore, land rigs, marine vessels and (2001), UL 1309/CSA245 and the performance
oil and gas drilling rigs. Instead of Polychloroprene requirements of IEC 60092-3.
(Neoprene), they are sheathed in our proprietary
elastomeric formulation which is not only mud-resistant Performance requirements of IEc 92-3.
but qualifies as a low-smoke zero-halogen (LSZH) cable Det Norske Veritas Type Approval Certificates E8797,
in accordance with IEEE 45 (1998), IEEE 1580 (2001) E8798, E8799 and E8800.
and type approved as Type M.
Manufactured to BIW Specifying Standard J104
This mud-resistant jacket is designed for use in areas
where ester-based drilling muds and fluids are present.
These cables are listed by ETL in accordance with IEEE
45 and type approved by DNV as resistant to NOVA
Plus, Petrofree LE and Petrofree drilling muds and
fluids. The cable was tested in accordance with NEK
606 for 56 days at 70C in each of the ester-based
muds mentioned above
This product can be manufactured in an unarmored
version.
Construction

1. Conductors Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page.
A mylar separator is used over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Armor Braided bronze in accordance with IEEE 1580 (2001).
4. Sheath Flame-retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580
(2001). Thickness as shown in tables on opposite page.
Features
Special ester-based mud-resistant jacket also provides superior resistance to oil,
abrasion, moisture, sunlight, crush and impact
Super-flexible construction
Meets IEEE 45 (1998) and IEEE 1580 (2001) for 600 and 2000 volts
Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 45 (1998), IEEE 1580 (2001), and
UL 1309/CSA 245 and IEEE 45 (1998) for 2000V.
Type approved by DNV. 65
www.DrakaMOG.com
Bostrig Type P
0807
Page 62 of 62

BOSTRIG TYPE P-MR POWER CABLE

single conductor / armored & sheathed and unarmored


4/0 AWG to 1111 MCM / 2000V
Armored & sheathed
Sheath Cable Diameter Impedance Ampacity Cable Weight
Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
SPBM2KV(HD)-4/0 026034M 4/0 112.6 .080 2.0 1.040 26.4 0.07 0.2 0.11 0.4 146 479 335 351 376 1190 1771
SPBM2KV(HD)-262 026035M 262 133.1 .080 2.0 1.090 27.7 0.06 0.2 0.10 0.3 162 531 382 407 436 1360 2024
SPBM2KV(HD)-313 026036M 313 158.7 .080 2.0 1.155 29.3 0.06 0.2 0.10 0.3 175 574 426 455 487 1580 2351
SPBM2KV(HD)-373 026037M 373 189.2 .080 2.0 1.225 31.1 0.05 0.2 0.10 0.3 189 620 476 516 553 1800 2678
SPBM2KV(HD)-444 026038M 444 225.2 .080 2.0 1.295 32.9 0.05 0.2 0.10 0.3 205 672 531 588 630 2130 3169
SPBM2KV(HD)-535 026039M 535 271.3 .110 2.8 1.475 37.5 0.04 0.01 0.10 0.3 200 656 596 630 675 2620 3899
SPBM2KV(HD)-646 026040M 646 327.5 .110 2.8 1.575 40.0 0.04 0.01 0.10 0.3 216 708 670 731 7783 3050 4538
SPBM2KV(HD)-777 026041M 777 394.2 .110 2.8 1.665 42.3 0.04 0.01 0.10 0.3 236 774 754 822 881 3570 5312
SPBM2KV(HD)-1111 026042M 1111 563.0 .125 3.2 1.990 48.3 0.04 0.01 0.10 0.3 257 843 942 1025 1098 4780 7113

Unarmored
Sheath Cable Diameter Impedance Ampacity Cable Weight
Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft- /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
SPM2KV(HD)-4/0 026015M 4/0 112.6 .105 2.7 .690 20.8 0.07 0.2 0.11 0.4 146 479 335 351 376 1060 1577
SPM2KV(HD)-262 026016M 262 133.1 .105 2.7 .820 22.1 0.06 0.2 0.10 0.3 162 531 382 407 436 1220 1815
SPM2KV(HD)-313 026017M 313 158.7 .105 2.7 .935 23.8 0.06 0.2 0.10 0.3 175 574 426 455 487 1430 2128
SPM2KV(HD)-373 026018M 373 189.2 .105 2.7 1.005 25.5 0.05 0.2 0.10 0.3 189 620 476 516 553 1640 2440
SPM2KV(HD)-444 026019M 444 225.2 .105 2.7 1.075 27.3 0.05 0.2 0.10 0.3 205 672 531 588 630 1940 2887
SPM2KV(HD)-535 026020M 535 271.3 .120 3.1 1.195 30.4 0.04 0.1 0.10 0.3 200 656 596 630 675 2370 3527
SPM2KV(HD)-646 026021M 646 327.5 .120 3.1 1.295 32.9 0.04 0.1 0.10 0.3 216 708 670 731 783 2800 4166
SPM2KV(HD)-777 026022M 777 394.2 .120 3.1 1.385 35.2 0.04 0.1 0.10 0.3 236 774 754 822 881 3300 4910
SPM2KV(HD)-1111 026023M 1111 563.0 .120 3.1 1.595 40.5 0.04 0.1 0.10 0.3 257 843 942 1025 1098 4500 6696

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

66
www.DrakaMOG.com
Bostrig Type P
0807
Page 25 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV & 2000V


Single conductor / unarmored
TYPE P POWER CABLE
600V or 0.6/1kV & 2000V
18 AWG to 1111 MCM
1 2

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates
design. They satisfy Transport Canadas cold bend at
No. 95/00161(E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored and
sheathed version. Manufactured to BIW Specifying Standard J104

Construction

1. Conductor Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001). Thickeness
as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600 & 2000V / IEC standards
for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V & 2000V.

67
www.DrakaMOG.com
Bostrig Type P
0807
Page 26 of 62

BOSTRIG TYPE P POWER CABLE

single conductor / unarmored


18 AWG to 1111 MCM / 600V or 0.6/1kV & 2000V
600V or 600/1000V
Sheath Cable Diameter Impedance Calculated Ampacity Cable Weight
Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
SP-18 026000 18 .030 0.76 .111 2.8 6.4 21.0 0.18 0.6 58 190 16 16 17 11 16
SP-16 026001 16 .030 0.76 .119 3.0 4.5 14.8 0.18 0.6 65 213 20 23 25 13 19
SP-14 026002 14 .030 0.76 .133 3.4 2.9 9.5 0.16 0.5 77 253 29 37 39 18 27
SP-12 026004 12 .030 0.76 .151 3.8 1.9 6.2 0.15 0.5 90 295 38 45 49 28 42
SP-10 026004 10 .030 0.76 .180 4.6 1.2 3.9 0.14 0.5 107 351 51 58 61 44 65
SP-8 026005 8 8.4 .045 1.1 .233 5.9 0.7 2.3 0.14 0.5 95 311 67 72 77 69 103
SP-6 026006 6 13.3 .045 1.1 .290 7.4 0.5 1.6 0.12 0.4 126 413 90 96 103 103 153
SP-5 026007 5 18.6 .045 1.1 .335 8.5 0.3 1.6 0.12 0.4 140 459 111 109 117 145 216
SP-4 026008 4 21.5 .045 1.11 .353 9.0 0.3 1.6 0.12 0.4 153 502 122 128 137 171 254
SP-3 026009 3 27.2 .045 1.1 .380 9.7 0.2 0.7 0.11 0.4 173 567 142 146 156 200 298
SP-2 026010 2 33.7 .045 1.1 .423 10.7 0.2 0.7 0.11 0.4 187 613 162 169 181 231 344
SP-1 026011 1 46.1 .055 1.4 .493 12.5 0.1 0.3 0.11 0.4 178 584 197 194 208 348 518
SP-1/0 026012 1/0 56.3 .055 1.4 .524 13.3 0.1 0.3 0.11 0.4 190 623 223 227 243 414 618
SP-2/0 026013 2/0 67.6 .055 1.4 .578 14.7 0.09 0.3 0.10 0.3 212 695 250 262 281 476 708
SP-3/0 026014 3/0 92.1 .055 1.4 .659 16.7 0.08 0.3 0.10 0.3 245 804 304 300 321 671 999

2000V
Sheath Cable Diameter Impedance Calculated Ampacity Cable Weight
Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
SP2KV-8 030477 8 0.055 1.40 0.265 6.7 0.695 2.28 0.108 0.354 82 269 67 72 77 74 111
SP2KV-6 030478 6 0.055 1.40 0.326 8.3 0.442 1.45 0.099 0.324 108 354 90 96 103 110 164
SP2KV-5 030479 5 0.055 1.40 0.354 9.0 0.332 1.09 0.097 0.318 120 393 111 109 117 147 220
SP2KV-4 030480 4 0.055 1.40 0.38 9.7 0.277 0.91 0.095 0.312 131 430 122 128 137 170 254
SP2KV-3 030481 3 0.055 1.40 0.42 10.7 0.221 0.72 0.092 0.302 148 485 142 146 156 206 307
SP2KV-2 030482 2 0.055 1.40 0.449 11.4 0.176 0.58 0.090 0.295 160 525 162 169 181 251 374
SP2KV-1 030483 1 0.065 1.65 0.519 13.2 0.141 0.46 0.091 0.298 158 518 197 194 208 341 507
SP2KV-1/0 029732 1/0 0.065 1.65 0.549 13.9 0.113 0.37 0.089 0.292 168 551 223 227 243 405 603
SP2KV-2/0 027055 2/0 0.065 1.65 0.594 15.1 0.092 0.30 0.088 0.289 184 604 250 262 281 499 742
SP2KV-3/0 030484 3/0 0.065 1.65 0.684 17.4 0.075 0.25 0.086 0.282 216 708 304 300 321 668 994
SP2KV(HD)-4/0 026015 4/0 112.6 0.105 2.7 .821 20.9 0.07 0.2 0.11 0.4 146 479 344 351 376 896 1333
SP2KV(HD)-262 026016 262 133.1 0.105 2.7 .895 22.7 0.06 0.2 0.10 0.3 162 531 382 407 436 1035 1540
SP2KV(HD)-313 026017 313 158.7 0.105 2.7 .966 24.5 0.06 0.2 0.10 0.3 175 574 426 455 487 1227 1826
SP2KV(HD)-373 026018 373 189.2 0.105 2.7 1.033 26.2 0.05 0.2 0.10 0.3 189 620 476 516 553 1424 2119
SP2KV(HD)-444 026019 444 225.2 0.105 2.7 1.114 28.3 0.05 0.2 0.10 0.3 205 672 531 588 630 1707 2540
SP2KV(HD)-535 026020 535 271.3 0.120 3.1 1.227 31.2 0.04 0.1 0.10 0.3 200 656 596 630 675 2025 3014
SP2KV(HD)-646 026021 646 327.5 0.120 3.1 1.331 33.3 0.04 0.1 0.10 0.3 216 708 670 731 783 2429 3615
SP2KV(HD)-777 026022 777 394.2 0.120 3.1 1.424 36.2 0.04 0.1 0.10 0.3 236 774 754 822 881 2896 4310
SP2KV(HD)-1111 026023 1111 563.0 0.120 3.1 1.675 42.5 0.04 0.1 0.10 0.3 257 843 942 1025 1098 3946 5872

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

68
www.DrakaMOG.com
Bostrig Type P
0807
Page 1 of 62

BOSTRIG TYPE P POWER CABLE 600V, 0.6/1kV & 2000V


Single conductor / armored and sheathed
TYPE P POWER CABLE
600V or 0.6/1kV & 2000V
8 AWG to 1111 MCM
1 2 3 4

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush
03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225.
Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating
No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J104
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.

Construction

1. Conductor Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Armor Braided bronze in accordance with IEEE 1580 (2001).
4. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600 & 2000V / IEC standards
for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V & 2000V.
69
www.DrakaMOG.com
Bostrig Type P
0807
Page 2 of 62

BOSTRIG TYPE P POWER CABLE

single conductor / armored and sheathed


8 AWG to 1111 MCM / 600V or 0.6/1kV & 2000V
600V
Sheath Cable Diameter Impedance Calculated Ampacity Cable Weight
Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
SPBS-8 026024 8 8.4 .060 1.5 .415 10.5 0.7 2.3 0.14 0.5 95 311 67 72 77 155 231
SPBS-6 026025 6 13.3 .060 1.5 .470 11.9 0.5 1.6 0.12 0.4 126 413 90 96 103 210 313
SPBS-5 026026 5 18.6 .060 1.5 .525 13.3 0.3 1.6 0.12 0.4 140 459 111 109 117 260 387
SPBS-4 026027 4 21.5 .060 1.5 .535 13.6 0.3 1.6 0.12 0.4 153 502 122 128 137 295 439
SPBS-3 026028 3 27.2 .060 1.5 .560 14.2 0.2 0.7 0.11 0.4 173 567 142 146 156 335 499
SPBS-2 026029 2 33.7 .060 1.5 .595 15.1 0.2 0.7 0.11 0.4 187 613 162 169 181 380 566
SPBS-1 026030 1 46.1 .060 1.5 .675 17.2 0.1 0.3 0.11 0.4 178 584 197 194 208 520 774
SPBS-1/0 026031 1/0 56.3 .060 1.5 .730 18.5 0.1 0.3 0.11 0.4 190 623 223 227 243 615 915
SPBS-2/0 026032 2/0 67.6 .060 1.5 .745 18.9 0.09 0.3 0.10 0.3 212 695 250 262 281 680 1012
SPBS-3/0 026033 3/0 92.1 .080 2.0 .890 22.6 0.08 0.3 0.10 0.3 245 804 304 300 321 940 1399

2000V
Sheath Cable Diameter Impedance Calculated Ampacity Cable Weight
Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
SPBS2KV-8 036754 8 0.045 1.14 0.43 10.9 0.696 2.28 0.138 0.453 82 269 67 72 77 157 234
SPBS2KV-6 036755 6 0.045 1.14 0.491 12.5 0.442 1.45 0.124 0.407 108 354 90 96 103 208 310
SPBS2KV-5 036756 5 0.045 1.14 0.519 13.2 0.333 1.09 0.120 0.394 120 393 111 109 117 253 376
SPBS2KV-4 036757 4 0.060 1.52 0.575 14.6 0.279 0.92 0.120 0.394 131 430 122 128 137 299 445
SPBS2KV-3 036758 3 0.060 1.52 0.615 15.6 0.222 0.73 0.115 0.377 148 485 142 146 156 346 515
SPBS2KV-2 036742 2 0.060 1.52 0.644 16.4 0.178 0.58 0.112 0.367 160 525 162 169 181 399 594
SPBS2KV-1 036759 1 0.060 1.52 0.714 18.1 0.143 0.47 0.110 0.361 158 518 197 194 208 509 757
SPBS2KV-1/0 036760 1/0 0.060 1.52 0.744 18.9 0.115 0.38 0.108 0.354 168 551 223 227 243 581 865
SPBS2KV-2/0 036761 2/0 0.060 1.52 0.789 20.0 0.095 0.31 0.105 0.344 184 604 250 262 281 688 1024
SPBS2KV-3/0 027068 3/0 0.080 2.03 0.939 23.8 0.079 0.26 0.105 0.344 216 708 304 300 321 937 1395
SPBS2KV(HD)-4/0 026034 4/0 112.6 .080 2.0 1.040 26.4 0.07 0.2 0.11 0.4 146 479 344 351 376 1195 1778
SPBS2KV(HD)-262 026035 262 133.1 .080 2.0 1.090 27.7 0.06 0.2 0.10 0.3 162 531 382 407 436 1350 2009
SPBS2KV(HD)-313 026036 313 158.7 .080 2.0 1.155 29.3 0.06 0.2 0.10 0.3 175 574 426 455 487 1550 2307
SPBS2KV(HD)-373 026037 373 189.2 .080 2.0 1.225 31.1 0.05 0.2 0.10 0.3 189 620 476 516 553 1785 2656
SPBS2KV(HD)-444 026038 444 225.2 .080 2.0 1.295 32.9 0.05 0.2 0.10 0.3 205 672 531 588 630 2065 3073
SPBS2KV(HD)-535 026039 535 271.3 .110 2.8 1.475 37.5 0.04 0.1 0.10 0.3 200 656 596 630 675 2540 3780
SPBS2KV(HD)-646 026040 646 327.5 .110 2.8 1.575 40.0 0.04 0.1 0.10 0.3 216 708 670 731 783 2950 4390
SPBS2KV(HD)-777 026041 777 394.2 .110 2.8 1.665 42.3 0.04 0.1 0.10 0.3 236 774 754 822 881 3450 5134
SPBS2KV(HD)-1111 026042 1111 563.0 .125 3.2 1.990 48.3 0.04 0.1 0.10 0.3 257 843 942 1025 1098 4700 6994

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

70
www.DrakaMOG.com
Bostrig Type P
0807
Page 27 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Two conductor / unarmored
TYPE P POWER CABLE
600V or 0.6/1kV
8 AWG to 777 MCM
1 2 3

Applications Approvals
BostrigTM Type P Marine and Offshore Cable is ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at Lloyds Registry of Shipping Approval Certificates
-40C and cold impact at -35C (CSA C 22.2 No. 0.3). No. 95/00161(E3) and 95-00162(E3)

This product is readily available in an armored and Transport Canada Approved AMS400-20-2
sheathed version. Manufactured to BIW Specifying Standard J105

CONSTRUCTION

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600 & 2000V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V & 2000V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

71
www.DrakaMOG.com
Bostrig Type P
0807
Page 28 of 62

BOSTRIG TYPE P POWER CABLE

two conductor / unarmored


8 AWG to 777 MCM / 600V or 0.6/1kV

Jacket Cable Diameter Impedance Calculated Ampacity Cable Weight


Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
DPN-8 026043 8 7.57 .060 1.5 .590 15.0 0.70 2.3 0.12 0.4 95 312 58 64 69 210 313
DPN-6 026044 6 12.5 .060 1.5 .705 17.9 0.46 1.5 0.11 0.4 126 413 83 85 91 315 469
DPN-5 026045 5 18.6 .060 1.5 .810 20.6 0.33 1.1 0.11 0.4 140 459 95 101 108 440 655
DPN-4 026046 4 21.5 .080 2.0 .870 22.1 0.29 1.0 0.10 0.3 153 502 104 110 118 520 774
DPN-3 026047 3 25.6 .080 2.0 .920 23.4 0.23 0.8 0.10 0.3 173 567 121 132 141 605 900
DPN-2 026048 2 30.7 .080 2.0 .985 25.0 0.18 0.6 0.10 0.3 187 613 138 149 160 685 1019
DPN-1 026049 1 46.0 .080 2.0 1.150 29.2 0.14 0.5 0.09 0.3 178 584 168 174 186 975 1451
DPN-1/0 026050 1/0 56.3 .080 2.0 1.260 32.0 0.12 0.4 0.09 0.3 190 623 190 199 213 1150 1711
DPN-2/0 026051 2/0 66.5 .080 2.0 1.320 33.5 0.09 0.3 0.09 0.3 212 695 213 242 259 1285 1912
DPN-3/0 026052 3/0 92.1 .110 2.8 1.560 39.6 0.08 0.3 0.09 0.3 245 804 259 265 284 1860 2768
DPN-4/0 026053 4/0 112.6 .110 2.8 1.660 42.2 0.07 0.2 0.09 0.3 259 850 293 307 329 2215 3296
DPN-262 026054 262 133.0 .125 3.2 1.830 46.5 0.06 0.2 0.09 0.3 247 810 325 358 383 2605 3877
DPN-313 026055 313 158.6 .125 3.2 1.965 49.9 0.05 0.2 0.09 0.3 270 886 362 391 419 3035 4517
DPN-373 026056 373 189.3 .125 3.2 2.105 53.5 0.04 0.1 0.09 0.3 292 958 405 442 473 3615 5380
DPN-444 026057 444 225.1 .125 3.2 2.245 57.0 0.04 0.1 0.09 0.3 318 1043 451 504 540 4140 6161
DPN-535 026058 535 271.2 .140 3.6 2.4905 63.4 0.04 0.1 0.09 0.3 291 954 507 538 576 4960 7381
DPN-646 026059 646 327.5 .140 3.6 2.695 68.5 0.04 0.1 0.09 0.3 314 1030 570 632 677 5880 8750
DPN-777 026060 777 393.8 .140 3.6 2.900 73.7 0.03 0.1 0.09 0.3 345 1132 641 684 733 7030 10462

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

72
www.DrakaMOG.com
Bostrig Type P
0807
Page 3 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Two conductor / armored and sheathed
TYPE P POWER CABLE
600V or 0.6/1kV
8 AWG to 777 MCM
1 2 3 4 5

Applications Approvals
BostrigTM Type P Marine and Offshore Cable is ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
applications (armored & sheathed) and meet the crush American Bureau of Shipping Approval Certificate
and impact resistance requirements (C&IR) of UL 2225. 03-HS347018C/3-PDA.

The standard insulation has a continuous operating Lloyds Registry of Shipping Approval Certificates
temperature of 125C allowing for higher ampacity No. 95/00161(E3) and 95-00162(E3)
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at
Manufactured to BIW Specifying Standard J104
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.
CONSTRUCTION

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
4. Armor Braided bronze in accordance with IEEE 1580 (2001).
5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
73
www.DrakaMOG.com
Bostrig Type P
0807
Page 4 of 62

BOSTRIG TYPE P POWER CABLE

two conductor / armored and sheathed


8 AWG to 777 MCM / 600V or 0.6/1kV

Sheath Cable Diameter Impedance Calculated Ampacity Cable Weight


Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
DPNBS-8 026108 8 7.57 .060 1.5 .765 19.4 0.70 2.3 0.12 0.4 95 312 58 64 69 405 603
DPNBS-6 026109 6 12.5 .080 2.0 .920 23.4 0.46 1.5 0.11 0.4 126 413 83 85 91 580 863
DPNBS-5 026110 5 18.6 .080 2.0 1.040 26.4 0.33 1.1 0.11 0.4 140 459 95 101 108 720 1071
DPNBS-4 026111 4 21.5 .080 2.0 1.090 27.7 0.29 1.0 0.10 0.3 153 502 104 110 118 850 1265
DPNBS-3 026112 3 25.6 .080 2.0 1.140 29.0 0.23 0.8 0.10 0.3 173 567 121 132 141 940 1399
DPNBS-2 026113 2 30.7 .080 2.0 1.205 30.6 0.18 0.6 0.10 0.3 187 613 138 149 160 1045 1555
DPNBS-1 026114 1 46.0 .110 2.8 1.430 36.3 0.14 0.5 0.09 0.3 178 584 168 174 186 1480 2202
DPNBS-1/0 026115 1/0 56.3 .110 2.8 1.535 39.0 0.12 0.4 0.09 0.3 190 623 190 199 213 1695 2522
DPNBS-2/0 026116 2/0 66.5 .110 2.8 1.600 40.6 0.09 0.3 0.09 0.3 212 695 213 242 259 1845 2746
DPNBS-3/0 026117 3/0 92.1 .125 3.2 1.870 47.5 0.08 0.3 0.09 0.3 245 804 259 265 284 2585 3825
DPNBS-4/0 026118 4/0 112.6 .125 3.2 1.975 50.2 0.07 0.2 0.09 0.3 259 850 293 307 329 2980 4435
DPNBS-262 026119 262 133.0 .125 3.2 2.145 54.5 0.06 0.2 0.09 0.3 247 810 325 358 383 3445 5127
DPNBS-313 026120 313 158.6 .140 3.6 2.305 58.6 0.05 0.2 0.09 0.3 270 886 362 391 419 4005 5960
DPNBS-373 026121 373 189.3 .140 3.6 2.445 62.1 0.04 0.1 0.09 0.3 292 958 405 442 473 4650 6920
DPNBS-444 026122 444 225.1 .140 3.6 2.585 65.7 0.04 0.1 0.09 0.3 318 1043 451 504 540 5240 7798
DPNBS-535 026123 535 271.2 .155 3.9 2.865 72.8 0.04 0.1 0.09 0.3 291 954 507 538 576 6175 9189
DPNBS-646 026124 646 327.5 .155 3.9 3.065 77.9 0.04 0.1 0.09 0.3 314 1030 570 632 677 7185 10692
DPNBS-777 026125 777 393.8 .155 3.9 3.270 83.01 0.03 0.1 0.09 0.3 345 1132 641 684 733 8420 12530

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

74
www.DrakaMOG.com
Bostrig Type P
0807
Page 29 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Three conductor / unarmored
TYPE P POWER CABLE
600V or 0.6/1kV
8 AWG to 777 MCM
1 2 3

Approvals
Applications
ETL/Intertek Testing Services Listed as Marine Shipboard
BostrigTM Type P Marine and Offshore Cable is
Cable in accordance with IEEE 45 (1998), IEEE 1580
primarily designed for power, control, signal and
(2001), UL 1309/CSA245 and the performance
instrumentation applications for offshore, land rigs,
requirements of IEC 60092-3.
marine vessels and oil and gas drilling rigs.
Det Norske Veritas Type Approval Certificates E8792,
Bostrig cables have excellent resistance to oil, abrasion,
E8793, E8794, E8795 and E8796.
moisture, sunlight and ester-based mud (Type P-MR).
American Bureau of Shipping Approval Certificate
The standard insulation has a continuous operating
03-HS347018C/3-PDA.
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Lloyds Registry of Shipping Approval Certificates
design. They satisfy Transport Canadas cold bend at No. 95/00161(E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3). Transport Canada Approved AMS400-20-2
This product is readily available in an armored and Manufactured to BIW Specifying Standard J105
sheathed version.

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

75
www.DrakaMOG.com
Bostrig Type P
0807
Page 30 of 62

BOSTRIG TYPE P POWER CABLE

three conductor / unarmored


8 AWG to 777 MCM / 600V or 0.6/1kV

Jacket Cable Diameter Impedance Calculated Ampacity Cable Weight


Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
TPN-8 026061 8 7.57 .060 1.5 .625 15.9 0.70 2.3 0.12 0.4 95 312 47 52 56 275 409
TPN-6 026062 6 12.5 .060 1.5 .750 19.1 0.46 1.5 0.11 0.4 126 413 63 70 75 420 625
TPN-5 026063 5 18.6 .080 2.0 .890 22.6 0.33 1.1 0.11 0.4 140 459 78 82 88 555 826
TPN-4 026064 4 21.5 .080 2.0 .925 23.5 0.29 1.0 0.10 0.3 153 502 86 92 99 695 1034
TPN-3 026065 3 25.6 .080 2.0 .975 24.8 0.23 0.8 0.10 0.3 173 567 99 108 116 805 1198
TPN-2 026066 2 30.7 .080 2.0 1.045 26.5 0.18 0.6 0.10 0.3 187 613 111 122 131 915 1362
TPN-1 026067 1 46.1 .080 2.0 1.225 31.1 0.14 0.5 0.09 0.3 178 584 137 143 153 1320 1964
TPN-1/0 026068 1/0 56.3 .080 2.0 1.340 34.0 0.12 0.4 0.09 0.3 190 623 156 164 176 1610 2395
TPN-2/0 026069 2/0 66.5 .110 2.8 1.440 36.6 0.09 0.3 0.09 0.3 212 695 175 188 201 1885 2805
TPN-3/0 026070 3/0 92.1 .110 2.8 1.665 42.3 0.08 0.3 0.09 0.3 245 804 213 218 234 2560 3810
TPN-4/0 026071 4/0 112.6 .125 3.2 1.800 45.7 0.07 0.2 0.09 0.3 259 850 241 252 270 3060 4555
TPN-262 026072 262 133.0 .125 3.2 1.950 49.5 0.06 0.2 0.09 0.3 247 810 267 294 315 3555 5290
TPN-313 026073 313 158.6 .125 3.2 2.095 53.2 0.05 0.2 0.09 0.3 270 886 298 321 344 4140 6161
TPN-373 026074 373 189.3 .125 3.2 2.245 57.0 0.04 0.1 0.09 0.3 292 958 333 361 387 4880 7262
TPN-444 026075 444 225.1 .140 3.6 2.425 61.6 0.04 0.1 0.09 0.3 318 1043 371 411 440 5800 8631
TPN-535 026076 535 271.2 .140 3.6 2.660 67.6 0.04 0.1 0.09 0.3 291 954 417 443 475 6945 10335
TPN-646 026077 646 327.5 .140 3.6 2.905 73.8 0.04 0.1 0.09 0.3 314 1030 469 516 553 8185 12818
TPN-777 026078 777 393.8 .140 3.6 3.095 78.6 0.03 0.1 0.09 0.3 345 1132 528 562 602 9695 14428

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

76
www.DrakaMOG.com
Bostrig Type P
0807
Page 5 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Three conductor / armored and sheathed
TYPE P POWER CABLE
600V or 0.6/1kV
8 AWG to 777 MCM
1 2 3 4 5

Approvals
Applications
ETL/Intertek Testing Services Listed as Marine Shipboard
BostrigTM Type P Marine and Offshore Cable is
Cable in accordance with IEEE 45 (1998), IEEE 1580
primarily designed for power, control, signal and
(2001), UL 1309/CSA245 and the performance
instrumentation applications for offshore, land rigs,
requirements of IEC 60092-3.
marine vessels and oil and gas drilling rigs.
Det Norske Veritas Type Approval Certificates E8792,
Bostrig cables have excellent resistance to oil, abrasion,
E8793, E8794, E8795 and E8796.
moisture, sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush 03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225. Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity Transport Canada Approved AMS400-20-2
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J105

-40C and cold impact at -35C (CSA C 22.2 No. 0.3).


This product is readily available in an unarmored version.
Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
4. Armor Braided bronze in accordance with IEEE 1580 (2001).
5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.
Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV
Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998)
for 600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
77
www.DrakaMOG.com
Bostrig Type P
0807
Page 6 of 62

BOSTRIG TYPE P POWER CABLE

three conductor / armored and sheathed


8 AWG to 777 MCM / 600V or 0.6/1kV

Sheath Cable Diameter Impedance Calculated Ampacity Cable Weight


Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
TPNBS-8 026126 8 7.57 .060 1.5 .835 21.2 0.70 2.3 0.12 0.4 95 312 47 52 56 480 714
TPNBS-6 026127 6 12.5 .080 2.0 .965 24.5 0.46 1.5 0.11 0.4 126 413 63 70 75 700 1042
TPNBS-5 026128 5 18.6 .080 2.0 1.120 28.5 0.33 1.1 0.11 0.4 140 459 78 82 88 900 1339
TPNBS-4 026129 4 21.5 .080 2.0 1.140 29.0 0.29 1.0 0.10 0.3 153 502 86 92 99 1040 1548
TPNBS-3 026130 3 25.6 .080 2.0 1.200 30.5 0.23 0.8 0.10 0.3 173 567 99 108 116 1160 1726
TPNBS-2 026131 2 30.7 .080 2.0 1.265 32.1 0.18 0.6 0.10 0.3 187 613 111 122 131 1295 1927
TPNBS-1 026132 1 46.1 .110 2.8 1.505 38.2 0.14 0.5 0.09 0.3 178 584 137 143 153 1850 2753
TPNBS-1/0 026133 1/0 56.3 .110 2.8 1.620 41.2 0.12 0.4 0.09 0.3 190 623 156 164 176 2190 3259
TPNBS-2/0 026134 2/0 66.5 .110 2.8 1.730 43.9 0.09 0.3 0.09 0.3 212 695 175 188 201 2500 3720
TPNBS-3/0 026135 3/0 92.1 .125 3.2 1.975 50.2 0.08 0.3 0.09 0.3 245 804 213 218 234 3330 4955
TPNBS-4/0 026136 4/0 112.6 .125 3.2 2.110 53.6 0.07 0.2 0.09 0.3 259 850 241 252 270 3890 5789
TPNBS-262 026137 262 133.0 .125 3.2 2.290 58.2 0.06 0.2 0.09 0.3 247 810 267 294 315 4515 6704
TPNBS-313 026138 313 158.6 .140 3.6 2.435 61.9 0.05 0.2 0.09 0.3 270 886 298 321 344 5170 7694
TPNBS-373 026139 373 189.3 .140 3.6 2.585 65.7 0.04 0.1 0.09 0.3 292 958 333 361 387 5975 8892
TPNBS-444 026140 444 225.1 .140 3.6 2.765 70.2 0.04 0.1 0.09 0.3 318 1043 371 411 440 6980 10387
TPNBS-535 026141 535 271.2 .140 3.6 3.030 77.0 0.04 0.1 0.09 0.3 291 954 417 443 475 8235 12255
TPNBS-646 026142 646 327.5 .140 3.6 3.275 83.2 0.04 0.1 0.09 0.3 314 1030 469 516 553 9575 14249
TPNBS-777 026143 777 393.8 .140 3.6 3.465 88.0 0.03 0.1 0.09 0.3 345 1132 528 562 602 11280 16786

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

78
www.DrakaMOG.com
Bostrig Type P
0807
Page 31 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Four conductor / unarmored
TYPE P POWER CABLE
600V or 0.6/1kV
8 AWG to 777 MCM
1 2 3

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates
design. They satisfy Transport Canadas cold bend at
No. 95/00161(E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored and
sheathed version. Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

79
www.DrakaMOG.com
Bostrig Type P
0807
Page 32 of 62

BOSTRIG TYPE P POWER CABLE

four conductor / unarmored


8 AWG to 777 MCM / 600V or 0.6/1kV

Jacket Cable Diameter Impedance Calculated Ampacity Cable Weight


Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
FPN-8 026079 8 7.57 .060 1.5 .690 17.5 0.70 2.3 0.12 0.4 95 312 47 52 56 350 521
FPN-6 026080 6 12.5 .060 1.5 .820 20.8 0.46 1.5 0.11 0.4 126 413 63 70 75 540 804
FPN-5 026081 5 18.6 .080 2.0 .980 24.9 0.33 1.1 0.11 0.4 140 459 78 82 88 775 1153
FPN-4 026082 4 21.5 .080 2.0 1.020 25.9 0.29 1.0 0.10 0.3 153 502 86 92 99 885 1317
FPN-3 026083 3 25.6 .080 2.0 1.080 27.4 0.23 0.8 0.10 0.3 173 567 99 108 116 1025 1525
FPN-2 026084 2 30.7 .080 2.0 1.160 29.5 0.18 0.6 0.10 0.3 187 613 111 122 131 1170 1741
FPN-1 026085 1 46.1 .080 2.0 1.360 34.5 0.14 0.5 0.09 0.3 178 584 137 143 153 1710 2545
FPN-1/0 026086 1/0 56.3 .110 2.8 1.510 38.4 0.12 0.4 0.09 0.3 190 623 156 164 176 2100 3125
FPN-2/0 026087 2/0 66.5 .110 2.8 1.590 40.4 0.09 0.3 0.09 0.3 212 695 175 188 201 2410 3586
FPN-3/0 026088 3/0 92.1 .125 3.2 1.875 47.6 0.08 0.3 0.09 0.3 245 804 213 218 234 3360 5000
FPN-4/0 026089 4/0 112.6 .125 3.2 1.995 50.7 0.07 0.2 0.09 0.3 259 850 241 252 270 3940 5863
FPN-262 026090 262 133.0 .125 3.2 2.165 55.0 0.06 0.2 0.09 0.3 247 810 267 294 315 4640 6905
FPN-313 026091 313 158.6 .140 3.6 2.355 59.8 0.05 0.2 0.09 0.3 270 886 298 321 344 5475 8148
FPN-373 026092 373 189.3 .140 3.6 2.525 64.1 0.04 0.1 0.09 0.3 292 958 333 361 387 6365 9472
FPN-444 026093 444 225.1 .140 3.6 2.695 68.5 0.04 0.1 0.09 0.3 318 1043 371 411 440 7500 11161
FPN-535 026094 535 271.2 .140 3.6 2.990 76.0 0.04 0.1 0.09 0.3 291 954 417 443 475 8970 13349
FPN-646 026095 646 327.5 .140 3.6 3.230 82.0 0.04 0.1 0.09 0.3 314 1030 469 516 553 10640 15834
FPN-777 026096 777 393.8 .140 3.6 3.445 87.5 0.03 0.1 0.09 0.3 345 1132 528 562 602 12730 18944

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.
The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor. If all conductors are
current carrying, the ampacity must be reduced by 0.8.

80
www.DrakaMOG.com
Bostrig Type P
0807
Page 7 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Four conductor / armored and sheathed
TYPE P POWER CABLE
600V or 0.6/1kV
8 AWG to 777 MCM
1 2 3 4 5

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush
03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225.
Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating
No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J105
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.
Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
4. Armor Braided bronze in accordance with IEEE 1580 (2001).
5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.
Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV
Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables complywith the Crush and Impact requirements of
UL 2225.
81
www.DrakaMOG.com
Bostrig Type P
0807
Page 8 of 62

BOSTRIG TYPE P POWER CABLE

four conductor / armored and sheathed


8 AWG to 777 MCM / 600V or 0.6/1kV

Sheath Cable Diameter Impedance Calculated Ampacity Cable Weight


Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
FPNBS-8 026144 8 7.57 .060 1.5 .910 23.1 0.70 2.3 0.13 0.4 95 312 47 52 56 605 900
FPNBS-6 026145 6 12.5 .080 2.0 1.045 26.5 0.46 1.5 0.12 0.4 126 413 63 70 75 890 1324
FPNBS-5 026146 5 18.6 .080 2.0 1.210 30.7 0.33 1.1 0.11 0.4 140 459 78 82 88 1140 1696
FPNBS-4 026147 4 21.5 .080 2.0 1.240 31.5 0.29 1.0 0.11 0.4 153 502 86 92 99 1265 1883
FPNBS-3 026148 3 25.6 .080 2.0 1.300 33.0 0.23 0.8 0.11 0.4 173 567 99 108 116 1415 2106
FPNBS-2 026149 2 30.7 .080 2.0 1.440 36.6 0.18 0.6 0.10 0.3 187 613 111 122 131 1675 2493
FPNBS-1 026150 1 46.1 .110 2.8 1.640 41.7 0.14 0.5 0.10 0.3 178 584 137 143 153 2300 3423
FPNBS-1/0 026151 1/0 56.3 .110 2.8 1.820 46.2 0.12 0.4 0.10 0.3 190 623 156 164 176 2860 4256
FPNBS-2/0 026152 2/0 66.5 .110 2.8 1.920 48.8 0.09 0.3 0.10 0.3 212 695 175 188 201 3150 4688
FPNBS-3/0 026153 3/0 92.1 .125 3.2 2.185 55.5 0.08 0.3 0.10 0.3 245 804 213 218 234 4220 6280
FPNBS-4/0 026154 4/0 112.6 .125 3.2 2.335 59.3 0.07 0.2 0.09 0.3 259 850 241 252 270 4920 7322
FPNBS-262 026155 262 133.0 .125 3.2 2.505 63.6 0.06 0.2 0.09 0.3 247 810 267 294 315 5700 8483
FPNBS-313 026156 313 158.6 .140 3.6 2.695 68.5 0.05 0.2 0.09 0.3 270 886 298 321 344 6620 9852
FPNBS-373 026157 373 189.3 .140 3.6 2.895 73.5 0.04 0.1 0.09 0.3 292 958 333 361 387 7590 11295
FPNBS-444 026158 444 225.1 .140 3.6 3.065 77.9 0.04 0.1 0.09 0.3 318 1043 371 411 440 8800 13096
FPNBS-535 026159 535 271.2 .140 3.6 3.360 85.3 0.04 0.1 0.09 0.3 291 954 417 443 475 10500 15626
FPNBS-646 026160 646 327.5 .140 3.6 3.600 91.4 0.04 0.1 0.09 0.3 314 1030 469 516 553 12290 18290
FPNBS-777 026161 777 393.8 .140 3.6 3.815 96.9 0.04 0.1 0.09 0.3 345 1132 528 562 602 14500 21578

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.
The ampacity of 4 conductor cables is based on three current carrying conductors and the fourth conductor being used as a Neutral or Grounding conductor. If all conductors are
current carrying, the ampacity must be reduced by 0.8.

82
www.DrakaMOG.com
Bostrig Type P
0807
Page 33 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Five conductor / armored and sheathed
TYPE P POWER CABLE
600V or 0.6/1kV
8 to 4/0 AWG
1 2 3

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates
design. They satisfy Transport Canadas cold bend at
No. 95/00161(E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored and
sheathed version. Manufactured to BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.

83
www.DrakaMOG.com
Bostrig Type P
0807
Page 34 of 62

BOSTRIG TYPE P POWER CABLE

five conductor / unarmored


8 to 4/0 AWG / 600V or 0.6/1kV

Jacket Cable Diameter Impedance Calculated Ampacity Cable Weight


Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
QPN-8 026097 8 7.57 .060 1.5 760 19.3 0.70 2.3 0.12 0.4 95 312 38 42 45 430 640
QPN-6 026098 6 12.5 .080 2.0 .955 24.3 0.46 1.5 0.11 0.4 126 413 50 56 60 700 1042
QPN-5 026099 5 18.6 .080 2.0 1.080 27.4 0.33 1.1 0.11 0.4 140 459 62 66 70 950 1414
QPN-4 026100 4 21.5 .080 2.0 1.125 28.6 0.29 1.0 0.10 0.3 153 502 69 74 79 1100 1637
QPN-3 026101 3 25.6 .110 2.8 1.195 30.4 0.23 0.8 0.10 0.3 173 567 79 86 93 1260 1875
QPN-2 026102 2 30.7 .110 2.8 1.280 32.5 0.18 0.6 0.10 0.3 187 613 89 98 105 1450 2158
QPN-1 026103 1 46.1 .125 3.2 1.565 39.8 0.14 0.5 0.09 0.3 178 584 110 114 122 2205 3282
QPN-1/0 026104 1/0 56.3 .125 3.2 1.715 43.6 0.12 0.4 0.09 0.3 190 623 125 131 141 2650 3945
QPN-2/0 026105 2/0 66.5 .125 3.2 1.790 45.5 0.09 0.3 0.09 0.3 212 695 140 150 161 3015 4487
QPN-3/0 026106 3/0 92.1 .140 3.6 2.075 52.7 0.08 0.3 0.09 0.3 245 804 170 174 187 4140 6161
QPN-4/0 026107 4/0 112.6 .140 3.6 2.210 56.1 0.07 0.2 0.09 0.3 259 850 193 202 216 4850 7218

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

84
www.DrakaMOG.com
Bostrig Type P
0807
Page 9 of 62

BOSTRIG TYPE P POWER CABLE 600V OR 0.6/1kV


Five conductor / armored and sheathed
TYPE P POWER CABLE
600V or 0.6/1kV
8 to 4/0 AWG
1 2 3 4 5

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush
03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225.
Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating
No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J105
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.
Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
4. Armor Braided bronze in accordance with IEEE 1580 (2001).
5. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.
Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for 0.6/1kV
Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
85
www.DrakaMOG.com
Bostrig Type P
0807
Page 10 of 62

BOSTRIG TYPE P POWER CABLE

five conductor / armored and sheathed


8 to 4/0 AWG / 600V or 0.6/1kV

Sheath Cable Diameter Impedance Calculated Ampacity Cable Weight


Type Draka Conductor Size Thickness (nominal) (Phase-Neutral) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
QPNBS-8 026162 8 7.57 .080 2.0 .980 24.9 0.70 2.3 0.13 0.4 95 312 38 42 45 710 1057
QPNBS-6 026163 6 12.5 .080 2.0 1.175 29.9 0.46 1.5 0.12 0.4 126 413 50 56 60 1045 1555
QPNBS-5 026164 5 18.6 .080 2.0 1.310 33.2 0.33 1.1 0.11 0.4 140 459 62 66 70 1350 2009
QPNBS-4 026165 4 21.5 .080 2.0 1.345 34.2 0.29 1.0 0.11 0.4 153 502 69 74 79 1510 2247
QPNBS-3 026166 3 25.6 .110 2.8 1.475 37.5 0.23 0.8 0.11 0.4 173 567 79 86 93 1775 2642
QPNBS-2 026167 2 30.7 .110 2.8 1.560 39.6 0.18 0.6 0.10 0.3 187 613 89 98 105 2000 2976
QPNBS-1 026168 1 46.1 .125 3.2 1.875 47.6 0.14 0.5 0.10 0.3 178 584 110 114 122 2930 4360
QPNBS-1/0 026169 1/0 56.3 .125 3.2 2.025 51.4 0.12 0.4 0.10 0.3 190 623 125 131 141 3435 5112
QPNBS-2/0 026170 2/0 66.5 .125 3.2 2.120 53.9 0.09 0.3 0.10 0.3 212 695 140 150 161 3830 5700
QPNBS-3/0 026171 3/0 92.1 .140 3.6 2.415 61.3 0.08 0.3 0.10 0.3 245 804 170 174 187 5150 7664
QPNBS-4/0 026172 4/0 112.6 .140 3.6 2.550 64.8 0.07 0.2 0.09 0.3 259 850 193 202 216 5930 8825

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

86
www.DrakaMOG.com
Bostrig Type P
0807
Page 51 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V


Overall shielded multiconductor /
armored and sheathed
TYPE P SIGNAL CABLE
600V
1 2 3 4 5 6 20, 18 & 16 AWG

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates No.
design. They satisfy Transport Canadas cold bend at
95/00161 (E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an unarmored version.
Manufactured tc BIW Specifying Standard J106

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over the cabled core.
4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
5 Armor Braided bronze in accordance with IEEE 1580 (2001).
6. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.
Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for
0.6/1kV
Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V.

87
www.DrakaMOG.com
Bostrig Type P
0807
Page 52 of 62

BOSTRIG TYPE P SIGNAL CABLE

overall shielded multiconductor / armored and sheathed


20, 18 & 16 AWG / 600V
20 AWG 0.61 mm2
Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Stranding Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C(0S)20PNBS-3 026503 3 19/32 .030 0.76 .060 1.5 .533 13.5 185 275

C(0S)20PNBS-4 026504 4 19/32 .030 0.76 .060 1.5 .557 14.2 210 313

C(0S)20PNBS-5 026505 5 19/32 .030 0.76 .060 1.5 .586 14.8 230 342

C(0S)20PNBS-6 026506 6 19/32 .030 0.76 .060 1.5 .614 15.6 255 380

18 AWG 0.96 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Stranding Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C(0S)18PNBS-3 026507 3 19/30 .030 0.76 .060 1.5 .540 13.7 205 305

C(0S)18PNBS-4 026508 4 19/30 .030 0.76 .060 1.5 .569 14.5 231 344

C(0S)18PNBS-5 026509 5 19/30 .030 0.76 .060 1.5 .613 15.6 259 389

C(0S)18PNBS-6 026510 6 19/30 .030 0.76 .060 1.5 .345 16.4 286 426

C(0S)18PNBS-25 25 19/30 .030 0.76 .060 1.5 1.074 27.3 705 1049

16 AWG 1.23 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Stranding Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C(0S)16PNBS-3 026511 3 19/29 .030 0.76 .060 1.5 .564 14.3 221 329

C(0S)16PNBS-4 026512 4 19/29 .030 0.76 .060 1.5 .584 14.8 242 360

C(0S)16PNBS-5 026513 5 19/29 .030 0.76 .060 1.5 .633 16.1 283 421

C(0S)16PNBS-6 026514 6 19/29 .030 0.76 .060 1.5 .666 16.9 313 466

C(0S)16PNBS-12 12 19/29 .030 0.76 .060 1.5 .820 20.8 470 699

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

88
www.DrakaMOG.com
Bostrig Type P
0807
Page 49 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V


Overall shielded multiconductor /
unarmored
TYPE P SIGNAL CABLE
600V
1 2 3 4 20, 18 & 16 AWG

Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates No.
design. They satisfy Transport Canadas cold bend at
95/00161 (E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored version.
Manufactured tc BIW Specifying Standard J106

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight,
mud, crush and impact
Super-flexible at 4/0 AWG and larger
Meets IEEE standards for 600V / IEC standards for
0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the
flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245
and IEEE 45 (1998) for 600V & 2000V.

89
www.DrakaMOG.com
Bostrig Type P
0807
Page 50 of 62

BOSTRIG TYPE P SIGNAL CABLE

overall shielded multiconductor / unarmored


20, 18 & 16 AWG / 600V
20 AWG 0.61 mm2
Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Stranding Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C(0S)20PN-3 026491 3 19/32 .030 0.76 .060 1.5 .345 8.8 65 97

C(0S)20PN-4 026492 4 19/32 .030 0.76 .060 1.5 .373 9.5 81 121

C(0S)20PN-5 026493 5 19/32 .030 0.76 .060 1.5 .403 10.2 92 137

C(0S)20PN-6 026494 6 19/32 .030 0.76 .060 1.5 .431 10.9 107 159

18 AWG 0.96 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Stranding Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C(0S)18PN-3 3 19/30 .030 0.76 .060 1.5 .358 9.1 78 116

C(0S)18PN-4 026496 4 19/30 .030 0.76 .060 1.5 .385 9.8 92 137

C(0S)18PN-5 026497 5 19/30 .030 0.76 .060 1.5 .435 11.0 113 168

C(0S)18PN-6 026498 6 19/30 .030 0.76 .060 1.5 .467 11.9 130 193

C(0S)18PN-25 25 19/30 .030 0.76 .060 1.5 .795 20.2 395 588

16 AWG 1.23 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Stranding Thickness Thickness (nominal) (approximate)
Designation Number Conductors in mm in mm in mm Lbs/mft Kg/km
C(0S)16PN-3 030645 3 19/29 .030 0.76 .060 1.5 .386 9.8 88 131

C(0S)16PN-4 026500 4 19/29 .030 0.76 .060 1.5 .400 10.2 104 155

C(0S)16PN-5 026501 5 19/29 .030 0.76 .060 1.5 .455 11.6 130 193

C(0S)16PN-6 026502 6 19/29 .030 0.76 .060 1.5 .488 12.4 150 223

C(0S)16PN-12 027052 12 19/29 .030 0.76 .060 1.5 .625 15.9 260 387

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

90
www.DrakaMOG.com
Bostrig Type P
0807
Page 45 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
unarmored
TYPE P SIGNAL CABLE
600V or 0.6/1kV
1 2 3 4
16 & 14 AWG
Applications Approvals
BostrigTM Type P Marine and Offshore Cable is ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
design. They satisfy Transport Canadas cold bend at Lloyds Registry of Shipping Approval Certificates No.
-40C and cold impact at -35C (CSA C 22.2 No. 0.3). 95/00161 (E3) and 95-00162(E3)

This product is readily available in an armored and Transport Canada Approved AMS400-20-2
sheathed version. Manufactured tc BIW Specifying Standard J106

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
91
www.DrakaMOG.com
Bostrig Type P
0807
Page 46 of 62

BOSTRIG TYPE P SIGNAL CABLE

individual and overall shielded multipair / unarmored and sheathed


16 & 14 AWG / 600V or 0.6/1kV

16 AWG 1.23 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Pairs in mm in mm in mm Lbs/mft Kg/km
TP(0S)16PN-1 026364 1 .030 0.76 .060 1.5 .350 8.9 65 97

TP(I/S-0S)16PN-2 026365 2 .030 0.76 .060 1.5 .620 15.6 170 253

TP(I/S-0S)16PN-3 026366 3 .030 0.76 .060 1.5 .665 16.9 215 320

TP(I/S-0S)16PN-4 026367 4 .030 0.76 .060 1.5 .695 17.7 240 357

TP(I/S-0S)16PN-5 026368 5 .030 0.76 .060 1.5 .740 18.8 275 409

TP(I/S-0S)16PN-6 026369 6 .030 0.76 .060 1.5 .805 20.1 320 476

TP(I/S-0S)16PN-7 026370 7 .030 0.76 .060 1.5 .805 20.1 345 513

TP(I/S-0S)16PN-8 026371 8 .030 0.76 .080 2.0 .985 25.0 475 707

TP(I/S-0S)16PN-10 026372 10 .030 0.76 .080 2.0 1.010 25.7 510 759

TP(I/S-0S)16PN-12 026373 12 .030 0.76 .080 2.0 1.065 27.1 585 871

TP(I/S-0S)16PN-16 026374 16 .030 0.76 .080 2.0 1.185 30.1 750 1116

TP(I/S-0S)16PN-20 026375 20 .030 0.76 .080 2.0 1.305 33.2 915 1362

TP(I/S-0S)16PN-24 026376 24 .030 0.76 .110 2.8 1.520 38.6 1165 1734

14 AWG 1.94 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Pairs in mm in mm in mm Lbs/mft Kg/km
TP(0S)14PN-1 026377 1 .030 0.76 .060 1.5 .395 10.0 85 126

TP(I/S-0S)14PN-2 026378 2 .030 0.76 .060 1.5 .640 16.3 180 268

TP(I/S-0S)14PN-3 026379 3 .030 0.76 .060 1.5 .680 17.3 235 350

TP(I/S-0S)14PN-4 026380 4 .030 0.76 .060 1.5 .650 19.1 290 432

TP(I/S-0S)14PN-5 026381 5 .030 0.76 .060 1.5 .810 20.6 345 513

TP(I/S-0S)14PN-6 026382 6 .030 0.76 .080 2.0 .920 23.4 450 670

TP(I/S-0S)14PN-7 026383 7 .030 0.76 .080 2.0 .920 23.4 475 707

TP(I/S-0S)14PN-8 026384 8 .030 0.76 .080 2.0 .995 25.3 540 804

TP(I/S-0S)14PN-10 026385 10 .030 0.76 .080 2.0 1.070 27.2 635 945

TP(I/S-0S)14PN-12 026386 12 .030 0.76 .080 2.0 1.165 29.6 760 1131

TP(I/S-0S)14PN-16 026387 16 .030 0.76 .080 2.0 1.300 33.0 975 1451

TP(I/S-0S)14PN-20 026388 20 .030 0.76 .110 2.8 1.490 37.9 1280 1905

TP(I/S-0S)14PN-24 026389 24 .030 0.76 .110 2.8 1.670 42.4 1515 2255

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

92
www.DrakaMOG.com
Bostrig Type P
0807
Page 21 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
armored and sheathed
TYPE P SIGNAL CABLE
600V or 0.6/1kV
1 2 3 4 5 6
16 & 14 AWG
Applications
Approvals
BostrigTM Type P Marine and Offshore Cable is
primarily designed for power, control, signal and ETL/Intertek Testing Services Listed as Marine Shipboard
instrumentation applications for offshore, land rigs, Cable in accordance with IEEE 45 (1998), IEEE 1580
marine vessels and oil and gas drilling rigs. (2001), UL 1309/CSA245 and the performance
requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion,
moisture, sunlight and ester-based mud (Type P-MR). Det Norske Veritas Type Approval Certificates E8792,
They are suitable for use in Class I, Division I and Zone I E8793, E8794, E8795 and E8796.
applications (armored & sheathed) and meet the crush American Bureau of Shipping Approval Certificate
and impact resistance requirements (C&IR) of UL 2225. 03-HS347018C/3-PDA.
The standard insulation has a continuous operating Lloyds Registry of Shipping Approval Certificates
temperature of 125C allowing for higher ampacity No. 95/00161(E3) and 95-00162(E3)
levels. Larger diameter cables carry a new flexible
Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3). Manufactured to BIW Specifying Standard J106

This product is readily available in an unarmored version.

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
5 Armor Braided bronze in accordance with IEEE 1580 (2001).
6. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.
Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV
Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
93
www.DrakaMOG.com
Bostrig Type P
0807
Page 22 of 62

BOSTRIG TYPE P SIGNAL CABLE

individual and overall shielded multipair / armored and sheathed


16 & 14 AWG / 600V or 0.6/1kV

16 AWG 1.23 mm2


Insulation Sheath Cable Diameter Characteristic Cable Weight
Type Draka Number of Thickness Thickness (nominal) Impedance Inductance Capacitance (approximate)
Designation Number Pairs in mm in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km
TP(0S)16PNBS-1 026429 1 .030 0.76 .060 1.5 .535 13.6 68 223 0.12 39 25 82 190 283

TP(I/S-0S)16PNBS-2 026430 2 .030 0.76 .060 1.5 .805 20.5 68 223 0.12 39 25 82 350 521

TP(I/S-0S)16PNBS-3 026431 3 .030 0.76 .080 2.0 .885 22.5 68 223 0.12 39 25 82 425 632

TP(I/S-0S)16PNBS-4 026432 4 .030 0.76 .080 2.0 .920 23.4 68 223 0.12 39 25 82 490 729

TP(I/S-0S)16PNBS-5 026433 5 .030 0.76 .080 2.0 .965 24.5 68 223 0.12 39 25 82 545 811

TP(I/S-0S)16PNBS-6 026434 6 .030 0.76 .080 2.0 1.025 26.0 68 223 0.12 39 25 82 610 908

TP(I/S-0S)16PNBS-7 026435 7 .030 0.76 .080 2.0 1.025 26.0 68 223 0.12 39 25 82 635 945

TP(I/S-0S)16PNBS-8 026436 8 .030 0.76 .080 2.0 1.205 30.6 68 223 0.12 39 25 82 800 1191

TP(I/S-0S)16PNBS-10 026437 10 .030 0.76 .080 2.0 1.235 31.4 68 223 0.12 39 25 82 875 1302

TP(I/S-0S)16PNBS-12 026438 12 .030 0.76 .080 2.0 1.285 32.6 68 223 0.12 39 25 82 965 1436

TP(I/S-0S)16PNBS-16 026439 16 .030 0.76 .110 2.8 1.465 37.2 68 223 0.12 39 25 82 1255 1868

TP(I/S-0S)16PNBS-20 026440 20 .030 0.76 .110 2.8 1.585 40.2 68 223 0.12 39 25 82 1470 2188

TP(I/S-0S)16PNBS-24 026441 24 .030 0.76 .125 3.2 1.835 46.6 68 223 0.12 39 25 82 1860 2786

14 AWG 1.94 mm2


Insulation Sheath Cable Diameter Characteristic Cable Weight
Type Draka Number of Thickness Thickness (nominal) Impedance Inductance Capacitance (approximate)
Designation Number Pairs in mm in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km
TP(0S)14PNBS-1 026693 1 .030 0.76 .060 1.5 .575 14.6 60 197 0.10 33 28 92 220 327

TP(I/S-0S)14PNBS-2 026443 2 .030 0.76 .060 1.5 .820 20.8 68 223 0.12 39 25 82 385 573

TP(I/S-0S)14PNBS-3 026444 3 .030 0.76 .080 2.0 .900 22.9 68 223 0.12 39 25 82 490 729

TP(I/S-0S)14PNBS-4 026445 4 .030 0.76 .080 2.0 .970 24.6 68 223 0.12 39 25 82 575 856

TP(I/S-0S)14PNBS-5 026446 5 .030 0.76 .080 2.0 1.030 26.2 68 223 0.12 39 25 82 650 967

TP(I/S-0S)14PNBS-6 026447 6 .030 0.76 .080 2.0 1.140 29.0 68 223 0.12 39 25 82 780 1161

TP(I/S-0S)14PNBS-7 026448 7 .030 0.76 .080 2.0 1.140 29.0 68 223 0.12 39 25 82 810 1205

TP(I/S-0S)14PNBS-8 026449 8 .030 0.76 .080 2.0 1.215 30.9 68 223 0.12 39 25 82 900 1339

TP(I/S-0S)14PNBS-10 026450 10 .030 0.76 .080 2.0 1.290 32.8 68 223 0.12 39 25 82 1030 1533

TP(I/S-0S)14PNBS-12 026451 12 .030 0.76 .110 2.8 1.445 36.7 68 223 0.12 39 25 82 1250 1860

TP(I/S-0S)14PNBS-16 026452 16 .030 0.76 .110 2.8 1.580 40.1 68 223 0.12 39 25 82 1525 2269

TP(I/S-0S)14PNBS-20 026453 20 .030 0.76 .125 3.2 1.800 45.7 68 223 0.12 39 25 82 1960 2917

TP(I/S-0S)14PNBS-24 026454 24 .030 0.76 .125 3.2 1.980 50.3 68 223 0.12 39 25 82 2260 3363

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

94
www.DrakaMOG.com
Bostrig Type P
0807
Page 43 of 62

BOSTRIG TYPE P CONTROL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
unarmored
TYPE P CONTROL CABLE
600V or 0.6/1kV
1 2 3 4 20 & 18 AWG
Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates No.
design. They satisfy Transport Canadas cold bend at
95/00161 (E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored and
sheathed version. Manufactured tc BIW Specifying Standard J105

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test
in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45
(1998) for 600V.
Bostrig Type P cables comply with the Crush and Impact require-
ments of UL 2225.

95
www.DrakaMOG.com
Bostrig Type P
0807
Page 44 of 62

BOSTRIG TYPE P CONTROL CABLE

individual and overall shielded multipair / unarmored


20 & 18 AWG / 600V or 0.6/1kV

20 AWG 0.61 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Pairs in mm in mm in mm Lbs/mft Kg/km
TP(0S)20PN-1 026338 1 .030 0.76 .060 1.5 .330 8.4 55 92

TP(I/S-0S)20PN-2 026339 2 .030 0.76 .060 1.5 .540 13.7 120 179

TP(I/S-0S)20PN-3 026340 3 .030 0.76 .060 1.5 .550 13.9 135 201

TP(I/S-0S)20PN-4 026341 4 .030 0.76 .060 1.5 .600 15.2 165 246

TP(I/S-0S)20PN-5 026342 5 .030 0.76 .060 1.5 .650 16.5 190 283

TP(I/S-0S)20PN-6 026343 6 .030 0.76 .060 1.5 .700 17.8 215 320

TP(I/S-0S)20PN-7 026344 7 .030 0.76 .060 1.5 .700 17.8 230 342

TP(I/S-0S)20PN-8 026345 8 .030 0.76 .060 1.5 .760 19.3 265 394

TP(I/S-0S)20PN-10 026346 10 .030 0.76 .080 2.0 .900 22.9 360 536

TP(I/S-0S)20PN-12 026347 12 .030 0.76 .080 2.0 .925 23.5 400 595

TP(I/S-0S)20PN-16 026348 16 .030 0.76 .080 2.0 1.030 26.2 510 759

TP(I/S-0S)20PN-20 026349 20 .030 0.76 .080 2.0 1.130 28.7 600 893

TP(I/S-0S)20PN-24 026350 24 .030 0.76 .080 2.0 1.265 32.1 720 1071

18 AWG 0.96 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Pairs in mm in mm in mm Lbs/mft Kg/km
TP(0S)18PN-1 1 .030 0.76 .060 1.5 .350 8.9 65 97

TP(I/S-0S)18PN-2 026352 2 .030 0.76 .060 1.5 .605 15.4 160 238

TP(I/S-0S)18PN-3 026353 3 .030 0.76 .060 1.5 .635 16.1 180 268

TP(I/S-0S)18PN-4 026354 4 .030 0.76 .060 1.5 .675 17.2 225 335

TP(I/S-0S)18PN-5 026355 5 .030 0.76 .060 1.5 .710 18.0 245 365

TP(I/S-0S)18PN-6 026356 6 .030 0.76 .060 1.5 .765 19.4 285 424

TP(I/S-0S)18PN-7 026357 7 .030 0.76 .060 1.5 .800 20.3 340 506

TP(I/S-0S)18PN-8 026358 8 .030 0.76 .080 2.0 .960 24.4 440 655

TP(I/S-0S)18PN-10 026359 10 .030 0.76 .080 2.0 1.025 26.0 515 766

TP(I/S-0S)18PN-12 026360 12 .030 0.76 .080 2.0 1.045 26.5 565 841

TP(I/S-0S)18PN-16 026361 16 .030 0.76 .080 2.0 1.160 29.5 720 1071

TP(I/S-0S)18PN-20 026362 20 .030 0.76 .080 2.0 1.240 31.5 825 1228

TP(I/S-0S)18PN-24 026363 24 .030 0.76 .110 2.8 1.450 36.8 1060 1577

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

96
www.DrakaMOG.com
Bostrig Type P
0807
Page 19 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multipair /
armored and sheathed
TYPE P SIGNAL CABLE
600V or 0.6/1kV
1 2 3 4 5 6 20 & 18 AWG
Applications Approvals
Bostrig Type P Marine and Offshore Cable is
TM
ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush
03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225.
Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating
No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at Manufactured to BIW Specifying Standard J106
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.
Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in
IEEE-1580 (2001). Thickness as shown on data sheet for unarmored version.
5. Armor Braided bronze in accordance with IEEE 1580 (2001).
6. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.
Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV
Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3,
Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
97
www.DrakaMOG.com
Bostrig Type P
0807
Page 20 of 62

BOSTRIG TYPE P SIGNAL CABLE

individual and overall shielded multipair / armored and sheathed


20 & 18 AWG / 600V or 0.6/1kV

20 AWG 0.61 mm2


Insulation Sheath Cable Diameter Characteristic Cable Weight
Type Draka Number of Thickness Thickness (nominal) Impedance Inductance Capacitance (approximate)
Designation Number Pairs in mm in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km
TP(0S)20PNBS-1 026403 1 .030 0.76 .060 1.5 .510 13.0 82 269 0.14 46 21 69 170 253

TP(I/S-0S)20PNBS-2 026404 2 .030 0.76 .060 1.5 .720 18.3 82 269 0.14 46 21 69 295 439

TP(I/S-0S)20PNBS-3 026405 3 .030 0.76 .060 1.5 .730 18.5 82 269 0.14 46 21 69 320 476

TP(I/S-0S)20PNBS-4 026406 4 .030 0.76 .060 1.5 .780 19.8 82 269 0.14 46 21 69 360 536

TP(I/S-0S)20PNBS-5 026407 5 .030 0.76 .080 2.0 .890 22.6 82 269 0.14 46 21 69 440 655

TP(I/S-0S)20PNBS-6 026408 6 .030 0.76 .080 2.0 .925 23.5 82 269 0.14 46 21 69 485 722

TP(I/S-0S)20PNBS-7 026409 7 .030 0.76 .080 2.0 .925 23.5 82 269 0.14 46 21 69 500 744

TP(I/S-0S)20PNBS-8 026410 8 .030 0.76 .080 2.0 .980 24.9 82 269 0.14 46 21 69 550 818

TP(I/S-0S)20PNBS-10 026411 10 .030 0.76 .080 2.0 1.120 28.5 82 269 0.14 46 21 69 690 1027

TP(I/S-0S)20PNBS-12 026412 12 .030 0.76 .080 2.0 1.150 29.2 82 269 0.14 46 21 69 730 1086

TP(I/S-0S)20PNBS-16 026413 16 .030 0.76 .080 2.0 1.250 31.8 82 269 0.l4 46 21 69 885 1317

TP(I/S-0S)20PNBS-20 026414 20 .030 0.76 .080 2.0 1.350 34.3 82 269 0.14 46 21 69 1060 1577

TP(I/S-0S)20PNBS-24 026415 24 .030 0.76 .110 2.8 1.545 39.2 82 269 0.14 46 21 69 1260 1875

18 AWG 0.96 mm2


Insulation Sheath Cable Diameter Characteristic Cable Weight
Type Draka Number of Thickness Thickness (nominal) Impedance Inductance Capacitance (approximate)
Designation Number Pairs in mm in mm in mm /kft - /km mH/kft mH/km pF/ft pF/m Lbs/mft Kg/km
TP(0S)18PNBS-1 026664 1 .030 0.76 .060 1.5 .535 13.6 73 239 0.13 43 23 75 185 275

TP(I/S-0S)18PNBS-2 026417 2 .030 0.76 .060 1.5 .785 19.5 73 239 0.13 43 23 75 350 521

TP(I/S-0S)18PNBS-3 026418 3 .030 0.76 .060 1.5 .845 21.5 73 239 0.13 43 23 75 395 588

TP(I/S-0S)18PNBS-4 026419 4 .030 0.76 .080 2.0 .895 22.7 73 239 0.13 43 23 75 465 692

TP(I/S-0S)18PNBS-5 026420 5 .030 0.76 .080 2.0 .930 23.6 73 239 0.13 43 23 75 505 752

TP(I/S-0S)18PNBS-6 026421 6 .030 0.76 .080 2.0 .990 25.2 73 239 0.13 43 23 75 570 848

TP(I/S-0S)18PNBS-7 026422 7 .030 0.76 .080 2.0 1.020 25.9 73 239 0.13 43 23 75 605 900

TP(I/S-0S)18PNBS-8 026423 8 .030 0.76 .080 2.0 1.180 30.0 73 239 0.13 43 23 75 725 1079

TP(I/S-0S)18PNBS-10 026424 10 .030 0.76 .080 2.0 1.245 31.6 73 239 0.13 43 23 75 845 1257

TP(I/S-0S)18PNBS-12 026425 12 .030 0.76 .080 2.0 1.265 32.1 73 239 0.13 43 23 75 910 1354

TP(I/S-0S)18PNBS-16 026426 16 .030 0.76 .110 2.8 1.440 36.6 73 239 0.13 43 23 75 1135 1689

TP(I/S-0S)18PNBS-20 026427 20 .030 0.76 .110 2.8 1.520 38.6 73 239 0.13 43 23 75 1350 2009

TP(I/S-0S)18PNBS-24 026428 24 .030 0.76 .110 2.8 1.760 44.7 73 239 0.13 43 23 75 1680 2500

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

98
www.DrakaMOG.com
Bostrig Type P
0807
Page 47 of 62

BOSTRIG TYPE P SIGNAL CABLE


Individual and overall shielded multi-triad
/ unarmored
TYPE P SIGNAL CABLE
600V or 0.6/1kV
1 2 3 4
18 & 16 AWG

Applications Approvals
BostrigTM Type P Marine and Offshore Cable is ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
The standard insulation has a continuous operating American Bureau of Shipping Approval Certificate
temperature of 125C allowing for higher ampacity 03-HS347018C/3-PDA.
levels. Larger diameter cables carry a new flexible
Lloyds Registry of Shipping Approval Certificates No.
design. They satisfy Transport Canadas cold bend at
95/00161 (E3) and 95-00162(E3)
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
Transport Canada Approved AMS400-20-2
This product is readily available in an armored and
sheathed version. Manufactured tc BIW Specifying Standard J106

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown in tables on opposite page.

Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
99
www.DrakaMOG.com
Bostrig Type P
0807
Page 48 of 62

BOSTRIG TYPE P SIGNAL CABLE

individual and overall shielded multitriad / unarmored


18 & 16 AWG / 0.6/1kV
18 AWG 0.96 mm2
Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Triads in mm in mm in mm Lbs/mft Kg/km
TT(0S)18PN-1 1 .030 0.76 .060 1.5 .360 9.1 75 111

TT(I/S-0S)18PN-2 026456 2 .030 0.76 .060 1.5 .605 15.4 165 246

TT(I/S-0S)18PN-3 026457 3 .030 0.76 .060 1.5 .640 16.3 210 313

TT(I/S-0S)18PN-4 026458 4 .030 0.76 .060 1.5 .705 17.9 265 394

TT(I/S-0S)18PN-5 026459 5 .030 0.76 .060 1.5 .775 19.7 315 469

TT(I/S-0S)18PN-6 026460 6 .030 0.76 .080 2.0 .880 22.4 390 580

TT(I/S-0S)18PN-8 026461 8 .030 0.76 .080 2.0 .955 24.5 495 737

TT(I/S-0S)18PN-12 026462 12 .030 0.76 .080 2.0 1.155 29.3 715 1064

16 AWG 1.23 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Triads in mm in mm in mm Lbs/mft Kg/km
TT(0S)16PN-1 026625 1 .030 0.76 .060 1.5 .370 9.4 85 126

TT(I/S-0S)16PN-2 026465 2 .030 0.76 .060 1.5 .630 16.0 180 268

TT(I/S-0S)16PN-3 026466 3 .030 0.76 .060 1.5 .670 17.0 235 350

TT(I/S-0S)16PN-4 026467 4 .030 0.76 .060 1.5 .740 18.8 295 439

TT(I/S-0S)16PN-5 026468 5 .030 0.76 .060 1.5 .815 20.7 355 528

TT(I/S-0S)16PN-6 026469 6 .030 0.76 .080 2.0 .915 23.1 446 662

TT(I/S-0S)16PN-8 026470 8 .030 0.76 .080 2.0 1.070 27.2 625 930

TT(I/S-0S)16PN-12 026471 12 .030 0.76 .080 2.0 1.215 30.9 805 1198
TT(I/S-0S)16PN-16 026472 16 .030 0.76 .080 2.0 1.360 34.5 1050 1563

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

100
www.DrakaMOG.com
Bostrig Type P
0807
Page 23 of 62

BOSTRIG TYPE P SIGNAL CABLE 600V OR 0.6/1kV


Individual and overall shielded multi-triad
/ armored and sheathed
TYPE P SIGNAL CABLE
600V or 0.6/1kV
1 2 3 4 5 6
18 & 16 AWG

Applications Approvals
BostrigTM Type P Marine and Offshore Cable is ETL/Intertek Testing Services Listed as Marine Shipboard
primarily designed for power, control, signal and Cable in accordance with IEEE 45 (1998), IEEE 1580
instrumentation applications for offshore, land rigs, (2001), UL 1309/CSA245 and the performance
marine vessels and oil and gas drilling rigs. requirements of IEC 60092-3.
Bostrig cables have excellent resistance to oil, abrasion, Det Norske Veritas Type Approval Certificates E8792,
moisture, sunlight and ester-based mud (Type P-MR). E8793, E8794, E8795 and E8796.
They are suitable for use in Class I, Division I and Zone I
American Bureau of Shipping Approval Certificate
applications (armored & sheathed) and meet the crush
03-HS347018C/3-PDA.
and impact resistance requirements (C&IR) of UL 2225.
Lloyds Registry of Shipping Approval Certificates
The standard insulation has a continuous operating
No. 95/00161(E3) and 95-00162(E3)
temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible Transport Canada Approved AMS400-20-2
design. They satisfy Transport Canadas cold bend at
Manufactured to BIW Specifying Standard J106
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product is readily available in an unarmored version.

Construction

1. Conductors Soft annealed stranded tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
3. Shield An aluminum/polyester tape with drain wire, 100% coverage, is applied over each twisted pair
and the cabled core. The single pair construction has only the overall shield.
4. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001). Thickness as shown on data sheet for unarmored version.
5 Armor Braided bronze in accordance with IEEE 1580 (2001).
6. Sheath Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.
Features
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Meets IEEE standards for 600V / IEC standards for 0.6/1kV
Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC
60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for
600V.
Bostrig Type P cables comply with the Crush and Impact requirements of
UL 2225.
101
www.DrakaMOG.com
Bostrig Type P
0807
Page 24 of 62

BOSTRIG TYPE P SIGNAL CABLE

individual and overall shielded multi-triad / armored and sheathed


18 & 16 AWG / 0.6/1kV

18 AWG 0.96 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Triads in mm in mm in mm Lbs/mft Kg/km
TT(0S)18PNBS-1 026473 1 .030 0.76 .060 1.5 .540 13.7 200 298

TT(I/S-0S)18PNBS-2 026474 2 .030 0.76 .060 1.5 .785 19.9 360 536

TT(I/S-0S)18PNBS-3 026475 3 .030 0.76 .060 1.5 .850 21.6 430 640

TT(I/S-0S)18PNBS-4 026476 4 .030 0.76 .080 2.0 .930 23.6 525 781

TT(I/S-0S)18PNBS-5 026477 5 .030 0.76 .080 2.0 .995 25.3 590 878

TT(I/S-0S)18PNBS-6 026478 6 .030 0.76 .080 2.0 1.100 28.0 715 1064

TT(I/S-0S)18PNBS-8 026479 8 .030 0.76 .080 2.0 1.175 29.9 825 1228

TT(I/S-0S)18PNBS-12 026480 12 .030 0.76 .110 2.8 1.440 36.6 1180 1756

TT(I/S-0S)18PNBS-16 026481 16 .030 0.76 .110 2.8 1.570 39.9 1450 2158

16 AWG 1.23 mm2


Insulation Sheath Cable Diameter Cable Weight
Type Draka Number of Thickness Thickness (nominal) (approximate)
Designation Number Triads in mm in mm in mm Lbs/mft Kg/km
TT(0S)16PNBS-1 026716 1 .030 0.76 .060 1.5 .550 14.0 210 313

TT(I/S-0S)16PNBS-2 026483 2 .030 0.76 .060 1.5 .810 20.6 380 566

TT(I/S-0S)16PNBS-3 026484 3 .030 0.76 .080 2.0 .890 22.6 485 722

TT(I/S-0S)16PNBS-4 026485 4 .030 0.76 .080 2.0 .960 24.4 570 848

TT(I/S-0S)16PNBS-5 026486 5 .030 0.76 .080 2.0 1.035 26.3 645 960

TT(I/S-0S)16PNBS-6 026487 6 .030 0.76 .080 2.0 1.130 28.7 770 1146

TT(I/S-0S)16PNBS-8 026488 8 .030 0.76 .080 2.0 1.290 32.8 950 1414

TT(I/S-0S)16PNBS-12 026489 12 .030 0.76 .110 2.8 1.495 38.0 1280 1905

TT(I/S-0S)16PNBS-16 026490 16 .030 0.76 .110 2.8 1.640 41.7 1565 2329

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

102
www.DrakaMOG.com
Bostrig Type P
0807
Page 57 of 62

BOSTRIG TYPE P-VFD POWER CABLE 2000V


Shielded three conductor / unarmored or
armored and sheathed
TYPE P VFD CABLE
2000V
1 2 3 4 5 6 7 1/0 AWG to 777 MCM
Applications
BostrigTM Type P shielded three conductor VFD Marine and Offshore Cable is designed specifically for use with
variable frequency AC motor drives. This cable is ETL listed per IEEE 45 (1998), IEEE 1580 (2001) and UL 1309/CSA 245.
Bostrig cables have excellent resistance to oil, abrasion, moisture and sunlight and ester-based mud (Type P-MR).
They are suitable for use in Class I, Division I and Zone I applications (armored & sheathed) and meet the crush and
impact resistance requirements (C&IR) of UL 2225 and complies with UL 1277 Type TC exposed runs requirements.
The standard insulation has a continuous operating temperature of 125C allowing for higher ampacity
levels. Larger diameter cables carry a new flexible design. They satisfy Transport Canadas cold bend at
-40C and cold impact at -35C (CSA C 22.2 No. 0.3).
This product can be manufactured in an unarmored or armored and sheathed version.

Construction

1. Conductors Soft annealed tinned copper per ASTM B 33. A polyester tape separator is used
over the conductor.
2. Insulation Bostrig Type P chemically cross-inked polyolefin (XLPO), meeting IEEE 1580 (2001).
Insulation is printed with phase markings as required.
3. Ground Conductors All Bostrig Type P-VFD Cables listed in this specification sheet are built using system
grounds equal to the aggregte cross-section of a phase conductor and can be in contact with
or isolated from the overall shield. A system ground is REQUIRED for supplying power from
the switchboard to the inverter and then to the motor. If the VFD cable is only being used
between the motor and the inverter, a cable with a lesser ground can be ordered.
4. Shield Braided tinner cooper for 95% coverage.
5. Jacket Flame-retardant Arctic Neoprene, complying with Type N Neoprene as required in IEEE-1580
(2001).
6. Armor (Optional) Braided bronze in accordance with IEEE 1580 (2001).
7. Sheath (Optional) Flame-retardant Arctic Neoprene applied over the armor, complying with Type N Neoprene
as required in IEEE 1580 (2001). Thickness as shown in tables on opposite page.

Features
Low smoke/zero halogen construction meets appropriate IEEE and IEC standards for fire, smoke, and toxicity
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Gigabit Ethernet 802.3Z compliant

Ratings
Meets all test requirements of IEEE 1580 (2001) and the flame test in IEC 60332-3, Category A.
Listed by ETL per IEEE 1580 (2001), UL 1309/CSA 245 and IEEE 45 (1998) for 2000V.
Type approved by DNV, ABS, Lloyds and Transport Canada.
Bostrig Type P cables comply to UL 1277 Type TC exposed runs
requirements and with the crush and impact requirements of UL 2225.

103
www.DrakaMOG.com
Bostrig Type P
0807
Page 58 of 62

BOSTRIG TYPE P-VFD POWER CABLE

shielded three conductor / unarmored or armored and sheathed


1/0 AWG to 777 MCM / 2000V
unarmored
Sheath Cable Diameter Calculated Ampacity Cable Weight
Type Draka Conductor Size Ground Size Thickness (nominal) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 AWG/MCM mm2 in mm in mm /kft - /km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
TP(OBS)N-1/0 036028 1/0 56.3 5 AWG 18.6 n/a 1.53 38.9 0.09 0.3 190 623 156 164 176 2280 3393
TP(OBS)N-2/0 036029 2/0 66.5 4 AWG 21.5 n/a 1.63 41.4 0.09 0.3 212 695 175 186 201 2640 3928
TP(OBS)N-4/0 036030 4/0 112.6 1 AWG 56.3 n/a 2.09 53.1 0.09 0.3 259 850 241 252 270 4480 6666
TP(OBS)N-262 036031 262 133.0 1 AWG 56.3 n/a 2.23 56.6 0.09 0.3 247 810 267 294 315 5050 7514
TP(OBS)N-313 036032 313 158.6 110 AWG 18.6 n/a 2.36 60.0 0.08 0.2 270 886 298 321 344 5860 8720
TP(OBS)N-373 036033 373 189.3 210 AWG 61.5 n/a 2.56 65.0 0.08 0.2 292 958 333 361 387 6950 10342
TP(OBS)N-444 036034 444 225.1 310 AWG 92.1 n/a 2.87 72.9 0.08 0.2 318 1043 371 411 440 8660 12886
TP(OBS)N-535 036035 535 271.2 310 AWG 92.1 n/a 3.03 77.0 0.09 0.3 291 954 417 443 475 9700 14437
TP(OBS)N-646 036036 646 327.5 410 AWG 112.6 n/a 3.18 80.8 0.09 0.3 314 1030 469 516 553 11400 16963
TP(OBS)N-777 036037 777 393.8 262 KCMIL 133.0 n/a 3.52 89.4 0.09 0.3 345 1132 528 582 602 13520 20118

armored and sheathed


Sheath Cable Diameter Calculated Ampacity Cable Weight
Type Draka Conductor Size Ground Size Thickness (nominal) Inductance Capacitance (measured @ C) (approximate)
Designation Number AWG/MCM mm2 AWG/MCM mm2 in mm in mm /kft - /km pF/ft pF/m 95 100 110 Lbs/mft Kg/km
TP(OBS)NBS-1/0 036038 4/0 112.6 5 AWG 18.6 .11 2.8 1.82 46.2 0.09 0.3 190 623 156 164 176 3020 4494
TP(OBS)NBS-2/0 036039 4/0 112.6 4 AWG 21.5 .11 2.8 1.92 48.8 0.09 0.3 212 695 175 188 201 3420 5089
TP(OBS)NBS-4/0 036040 4/0 112.6 1 AWG 56.3 .11 2.8 2.38 60.4 0.09 0.3 259 850 241 252 270 5510 8199
TP(OBS)NBS-262 036041 262 133.1 1 AWG 56.3 .11 2.8 2.52 64.0 0.09 0.3 247 810 267 294 315 6130 9121
TP(OBS)NBS-313 036042 313 158.7 110 AWG 18.6 .11 2.8 2.65 67.3 0.08 0.2 270 886 298 321 344 7010 10431
TP(OBS)NBS-373 036043 373 189.2 210 AWG 61.5 .14 3.6 2.90 73.7 0.08 0.2 292 958 333 361 387 8360 12440
TP(OBS)NBS-444 036044 444 225.2 310 AWG 92.1 .14 3.6 3.21 81.5 0.08 0.2 318 1043 371 411 440 10230 15222
TP(OBS)NBS-535 036045 535 271.3 310 AWG 92.1 .14 3.6 3.37 85.6 0.09 0.3 291 954 417 443 475 11350 16889
TP(OBS)NBS-646 036046 646 327.5 410 AWG 112.6 .14 3.6 3.52 89.4 0.09 0.3 314 1030 469 516 553 13130 19537
TP(OBS)NBS-777 036047 777 394.2 262 KCMIL 133.0 .14 3.6 3.86 98.0 0.09 0.3 345 1132 528 582 602 15420 22944

This information is provided for reference only, please consult the factory or your representative to confirm all engineering information,
This information is not meant to replace the information in the appropriate and applicable standard or code.

Ampacity based on 45C ambient temperature: 95C values based on ABS MODU Rules Table 6 - 1OOC values based on IEEE-45 Table 25 - 11 OC values based on IEEE-45
Table 25 corrected for conductor temperature. Ampacity de-rating factor for cables installed in conduit: 4 AWG and smaller multiply by O.72; 2 AWG thru 3/OAWG multiply by
0.66; 4/0 AWG thru 1000 MCM multiply by O.64.

PHASE CONDUCTOR (3)


SYSTEM GROUND (3)
FILLERS (AS REQUIRED)
MYLAR TAPE
BRAIDED SHIELD
JACKET
BRAIDED ARMOR
SHEATH

104
www.DrakaMOG.com
Marine & Offshore
Product Specification J-124
IECIEEEUL
Conductor
BOSTRIG MHV-15 CABLE Soft annealed tinned copper.
Stranding as shown in table below.
Single Conductor Power (Type N Jacket) Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
15 kV (IEC 12/20 kV) Shielded - 133% Level EPR.

Unarmored Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-124, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Application mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Bostrig MHV-15 single conductor 15,000 volt shielded cables are suitable for use in 2001. Type approved by DNV, ABS and LRS.
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 108


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-15-2 2 30.7 150/24 .220 5.59 .080 2.03 1.130 28.70 790 1175
MHV-15-1 1 46.0 225/24 .220 5.59 .080 2.03 1.200 30.48 950 1414
MHV-15-1/0 1/0 56.3 275/24 .220 5.59 .080 2.03 1.250 31.75 1050 1563
MHV-15-2/0 2/0 66.5 325/24 .220 5.59 .080 2.03 1.270 32.26 1150 1711
MHV-15-3/0 3/0 92.1 450/24 .220 5.59 .085 2.16 1.400 35.56 1430 2128
MHV-15-4/0 4/0 112.6 550/24 .220 5.59 .085 2.16 1.450 36.83 1600 2381
MHV-15-262 262 133.0 650/24 .220 5.59 .085 2.16 1.500 38.10 1760 2619
MHV-15-313 313 158.6 775/24 .220 5.59 .090 2.29 1.580 40.13 2000 2976
MHV-15-373 373 189.3 925/24 .220 5.59 .090 2.29 1.660 42.16 2250 3348
MHV-15-444 444 225.1 1100/24 .220 5.59 .110 2.80 1.770 44.96 2620 3899 TYPE N JACKET 15KV
MHV-15-535 535 271.2 1325/24 .220 5.59 .110 2.80 1.860 47.24 3000 4464
MHV-15-646 646 327.5 1600/24 .220 5.59 .110 2.80 1.980 50.29 3500 5209
MHV-15-777 777 393.8 1925/24 .220 5.59 .110 2.80 2.070 52.58 4000 5953
MHV-15-1111 1111 562.8 2750/24 .220 5.59 .115 2.92 2.300 58.42 5300 7887

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV15_108_109_2_00
105
Marine & Offshore
Product Specification J-120
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV-15 CABLE Stranding as shown in table below.

Single Conductor Power (Type N Jacket) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
15 kV (IEC 8.7/15 kV) Shielded - 100% Level EPR.

Insulation
Unarmored Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-120, and
flame test in IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Application mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Bostrig MHV-15 single conductor 15,000 volt shielded cables are suitable for use in 2001. Type approved by DNV, ABS and LRS.
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c - 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 106


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-15-2 2 30.7 150/24 .177 4.50 .080 2.03 1.050 26.67 700 1042
MHV-15-1 1 46.0 225/24 .177 4.50 .080 2.03 1.110 28.19 860 1280
MHV-15-1/0 1/0 56.3 275/24 .177 4.50 .080 2.03 1.170 29.72 960 1429
MHV-15-2/0 2/0 66.5 325/24 .177 4.50 .080 2.03 1.190 30.23 1040 1548
MHV-15-3/0 3/0 92.1 450/24 .177 4.50 .080 2.03 1.310 33.27 1310 1950
MHV-15-4/0 4/0 112.6 550/24 .177 4.50 .080 2.03 1.370 34.80 1480 2202
MHV-15-262 262 133.0 650/24 .177 4.50 .085 2.16 1.420 36.07 1650 2455
MHV-15-313 313 158.6 775/24 .177 4.50 .085 2.16 1.480 37.59 1860 2768
MHV-15-373 373 189.3 925/24 .177 4.50 .090 2.29 1.560 39.62 2120 3155
MHV-15-444 444 225.1 1100/24 .177 4.50 .090 2.29 1.630 41.10 2410 3586
TYPE N JACKET 15KV
MHV-15-535 535 271.2 1325/24 .177 4.50 .110 2.80 1.760 44.71 2850 4241
MHV-15-646 646 327.5 1600/24 .177 4.50 .110 2.80 1.870 47.50 3270 4866
MHV-15-777 777 393.8 1925/24 .177 4.50 .110 2.80 2.970 50.04 3800 5655
MHV-15-1111 1111 562.8 2750/24 .177 4.50 .110 2.80 2.190 55.63 5100 7590

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857
ISO9001
QSC3497
www.drakausa.com
106 BG_MHV15_106_107_2_00
Marine & Offshore
Product Specification J-124
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV-15B CABLE Stranding as shown in table below.

Conductor Shield
Single Conductor Power (Type N Jacket) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
15 kV - Shielded - 133% Level
Insulation
Armored Only Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.
Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-124, and flame test in IEC 60332-3, cat
A, A/F.
Application Rating
Bostrig MHV-15B single conductor 15,000 volt shielded cables are suitable for use in com- Listed by a Nationally Recognized Testing Lab (ETL) in confor-
mercial marine applications, MODUs, and platforms where flame retardant cables having mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
excellent physical and electrical properties are required. The cables have excellent resistance to 2001. Type approved by DNV, ABS and LRS.
oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with
either a fully insulated grounding conductor or an un-insulated grounding conductor evenly
distributed in the interstices.

1/c- 15 kV Shielded - 133% Level 174


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-15B-2 2 30.7 150/24 .220 5.59 .080 2.03 1.190 30.23 970 1444
MHV-15B-l 1 46.0 225/24 .220 5.59 .080 2.03 1.260 32.00 1130 1756
MHV-15B-l/0 1/0 56.3 275/24 .220 5.59 .080 2.03 1.310 33.27 1280 1905
MHV-15B-2/0 2/0 66.5 325/24 .220 5.59 .080 2.03 1.330 33.78 1380 2054
MHV-15B-3/0 3/0 92.1 450/24 .220 5.59 .085 2.16 1.460 37.08 1680 2500
MHV-15B-4/0 4/0 112.6 550/24 .220 5.59 .085 2.16 1.510 38.35 1870 2783
MHV-15B-262 262 133.0 650/24 .220 5.59 .085 2.16 1.560 39.62 2050 3051
MHV-15B-313 313 158.6 775/24 .220 5.59 .090 2.29 1.640 41.66 2300 3423
TYPE N JACKET 15KV

MHV-15B-373 373 189.3 925/24 .220 5.59 .090 2.29 1.720 43.69 2550 3795
MHV-15B-444 444 225.1 1100/24 .220 5.59 .110 2.80 1.830 46.48 2950 4390
MHV-15B-535 535 271.2 1325/24 .220 5.59 .110 2.80 1.920 48.77 3350 4985
MHV-15B-646 646 327.5 1600/24 .220 5.59 .110 2.80 2.040 51.82 3900 5804
MHV-15B-777 777 393.8 1925/24 .220 5.59 .110 2.80 2.130 54.10 4400 6548
MHV-15B-1111 1111 562.8 2750/24 .220 5.59 .115 2.92 2.360 59.94 5750 8557

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV15B_174_2_00
107
Marine & Offshore
Product Specification J-120
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV-15B CABLE Stranding as shown in table below.
Conductor Shield
Single Conductor Power (Type N Jacket) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
15 kV - Shielded - 100% Level
Insulation
Armored Only Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.
Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.
Armor
Braided Bronze.
Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-120 and flame test in IEC 60332-3, cat
A, A/F.

Rating
Application Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Bostrig MHV-15B single conductor 15,000 volt shielded cables are suitable for use in mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
commercial marine applications, MODUs, and platforms where flame retardant cables 2001. Type approved by DNV, ABS and LRS.
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c- 15 kV Shielded - 100% Level 171


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-15B-2 2 30.7 150/24 .177 4.50 .080 2.03 1.110 28.19 860 1280
MHV-15B-1 1 46.0 225/24 .177 4.50 .080 2.03 1.170 29.72 1040 1547
MHV-15B-1/0 1/0 56.3 275/24 .177 4.50 .080 2.03 1.230 31.24 1140 1697
MHV-15B-2/0 2/0 66.5 325/24 .177 4.50 .080 2.03 1.250 31.75 1220 1816
MHV-15B-3/0 3/0 92.1 450/24 .177 4.50 .080 2.03 1.370 34.80 1550 2307
MHV-15B-4/0 4/0 112.6 550/24 .177 4.50 .080 2.03 1.430 36.32 1720 2560
MHV-15B-262 262 133.0 650/24 .177 4.50 .085 2.16 1.480 37.59 1900 2828
MHV-15B-313 313 158.6 775/24 .177 4.50 .085 2.16 1.540 39.12 2150 3200
MHV-15B-373 373 189.3 925/24 .177 4.50 .090 2.29 1.620 41.15 2400 3572 TYPE N JACKET 15KV
MHV-15B-444 444 225.1 1100/24 .177 4.50 .090 2.29 1.690 42.93 2750 4092
MHV-15B-535 535 271.2 1325/24 .177 4.50 .110 2.80 1.820 46.23 3200 4762
MHV-15B-646 646 327.5 1600/24 .177 4.50 .110 2.80 1.930 49.02 3650 5432
MHV-15B-777 777 393.8 1925/24 .177 4.50 .110 2.80 2.030 51.56 4150 6176
MHV-15B-1111 1111 562.8 2750/24 .177 4.50 .110 2.80 2.250 57.15 5500 8185

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857
QSC3497
www.drakausa.com BG_MHV5BS_171_2_00
108
Marine & Offshore
Product Specification J-124
IECIEEEUL
Conductor
Soft annealed tinned copper.

BOSTRIG MHV-15BS CABLE Stranding as shown in table below.


Conductor Shield
Single Conductor Power (Type N Jacket & Sheath) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
15 kV (IEC 12/20 kV) Shielded - 133% Level Insulation
Armored and Sheathed Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.
Jacket and Sheath
Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.
Armor
Braided Bronze.
Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-124, and flame test in
IEC 60332-3, cat A, A/F.

Application Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Bostrig MHV-15BS single conductor 15,000 volt shielded cables are suitable for use in
mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
commercial marine applications, MODUs, and platforms where flame retardant cables
2001. Type approved by DNV, ABS and LRS.
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor.

1/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 109


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-15BS-2 2 30.7 150/24 .220 5.59 .080/.080 2.03/2.03 1.360 34.54 1200 1786
MHV-15BS-1 1 46.0 225/24 .220 5.59 .080/.080 2.03/2.03 1.420 36.07 1400 2083
MHV-15BS-l/0 1/0 56.3 275/24 .220 5.59 .080/.080 2.03/2.03 1.470 37.34 1500 2232
MHV-15BS-2/0 2/0 66.5 325/24 .220 5.59 .080/.080 2.03/2.03 1.490 37.85 1600 2381
MHV-15BS-3/0 3/0 92.1 450/24 .220 5.59 .085/.080 2.16/2.03 1.630 41.40 1920 2857
MHV-15BS-4/0 4/0 112.6 550/24 .220 5.59 .085/.080 2.16/2.03 1.680 42.67 2100 3125
MHV-15BS-262 262 133.0 650/24 .220 5.59 .085/.080 2.16/2.80 1.790 45.47 2400 3571
MHV-15BS-313 313 158.6 775/24 .220 5.59 .090/.110 2.29/2.80 1.870 47.59 2650 3943
TYPE N JACKET 15KV

MHV-15BS-373 373 189.3 925/24 .220 5.59 .090/.110 2.29/2.80 1.940 49.28 2950 4390
MHV-15BS-444 444 225.1 1100/24 .220 5.59 .110/.110 2.80/2.80 2.050 52.07 3400 5060
MHV-15BS-535 535 271.2 1325/24 .220 5.59 .110/.110. 2.80/2.80 2.150 54.61 3800 5655
MHV-15BS-646 646 327.5 1600/24 .220 5.59 .110/.110 2.80/2.80 2.260 57.40 4300 6399
MHV-15BS-777 777 393.8 1925/24 .220 5.59 .110/.110 2.80/2.80 2.360 59.94 4800 7143
MHV-15BS-1111 1111 562.8 2750/24 .220 5.59 .115/.110 2.92/2.80 2.580 65.53 6200 9227

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV15_108_109_2_00
109
Marine & Offshore
Product Specification J-120
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV-15BS CABLE Stranding as shown in table below.

Single Conductor Power (Type N Jacket & Sheath) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
15 kV (IEC 8.7/15 kV) Shielded - 100% Level EPR.

Insulation
Armored and Sheathed Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the metallic braid shield and outer
sheath over the armor are flame retardant, heavy duty arctic
Neoprene. Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-120, and
flame test in IEC 60332-3, cat A, A/F.
Application Rating
Bostrig MHV-15BS single conductor 15,000 volt shielded cables are suitable for use in Listed by a Nationally Recognized Testing Lab (ETL) in conformance
commercial marine applications, MODUs, and platforms where flame retardant cables to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
having excellent physical and electrical properties are required. The cables have excellent approved by DNV, ABS and LRS.
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor.

1/c - 15 kV (IEC 8.7/15kV) Shielded - 100% Level 107


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-15BS-2 2 30.7 150/24 .177 4.50 .080/.080 2.03/2.03 1.270 32.26 1060 1577
MHV-15BS-1 1 46.0 225/24 .177 4.50 .080/.080 2.03/2.03 1.330 33.78 1240 1845
MHV-15BS-1/0 1/0 56.3 275/24 .177 4.50 .080/.080 2.03/2.03 1.390 35.31 1360 2024
MHV-15BS-2/0 2/0 66.5 325/24 .177 4.50 .080/.080 2.03/2.03 1.410 35.81 1440 2143
MHV-15BS-3/0 3/0 92.1 450/24 .177 4.50 .080/.080 2.03/2.03 1.530 38.86 1780 2649
MHV-15BS-4/0 4/0 112.6 550/24 .177 4.50 .080/.080 2.03/2.03 1.580 40.13 1960 2917
MHV-15BS-262 262 133.0 650/24 .177 4.50 .085/.080 2.16/2.03 1.640 41.66 2140 3185
MHV-15BS-313 313 158.6 775/24 .177 4.50 .085/.110 2.16/2.80 1.760 44.70 2500 3720
TYPE N JACKET 15KV

MHV-15BS-373 373 189.3 925/24 .177 4.50 .090/.110 2.29/2.80 1.850 46.99 2790 4152
MHV-15BS-444 444 225.1 1100/24 .177 4.50 .090/.110 2.29/2.80 1.920 48.77 3100 4613
MHV-15BS-535 535 271.2 1325/24 .177 4.50 .110/.110 2.80/2.80 2.050 52.07 3600 5357
MHV-15BS-646 646 327.5 1600/24 .177 4.50 .110/.110 2.80/2.80 2.150 54.61 4050 6027
MHV-15BS-777 777 393.8 1925/24 .177 4.50 .110/.110 2.80/2.80 2.260 57.40 4620 6875
MHV-15BS-1111 1111 562.8 2750/24 .177 4.50 .110/.110 2.80/2.80 2.480 62.99 6000 8929

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV15_106_107_2_00
110
Marine & Offshore
Product Specification J-121

TYPE N JACKET 5KV


IECIEEEUL
Conductor
BOSTRIG MHV-5 CABLE Soft annealed tinned copper.
Stranding as shown in table below.
Single Conductor Power (Type N Jacket) Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level EPR.

Unarmored Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-121, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Application mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Bostrig MHV-5 single conductor 5,000 volt shielded cables are suitable for use in 2001. Type approved by DNV, ABS and LRS.
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight

1/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 100


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-5-8 8 7.57 37/24 .090 2.29 .060 1.53 .660 16.76 280 417
MHV-5-6 6 12.5 61/24 .090 2.29 .060 1.53 .720 18.29 340 506
MHV-5-5 5 18.6 91/24 .090 2.29 .060 1.53 .750 19.05 400 595
MHV-5-4 4 21.5 105/24 .090 2.29 .060 1.53 .790 20.07 430 640
MHV-5-2 2 30.7 150/24 .090 2.29 .060 1.53 .850 21.59 520 774
MHV-5-1 1 46.0 225/24 .090 2.29 .080 2.03 .950 24.13 700 1042
MHV-5-1/0 1/0 56.3 275/24 .090 2.29 .080 2.03 1.000 25.54 790 1176
MHV-5-2/0 2/0 66.5 325/24 .090 2.29 .080 2.03 1.020 25.91 860 1280
MHV-5-3/0 3/0 92.1 450/24 .095 2.40 .080 2.03 1.130 28.70 1100 1637
MHV-5-4/0 4/0 112.6 550/24 .095 2.40 .080 2.03 1.170 29.72 1250 1860
MHV-5-262 262 133.0 650/24 .095 2.40 .080 2.03 1.220 30.99 1400 2083
MHV-5-313 313 158.6 775/24 .095 2.40 .080 2.03 1.310 33.27 1650 2456
MHV-5-373 373 189.3 925/24 .095 2.40 .080 2.03 1.380 35.05 1900 2828
MHV-5-444 444 225.1 1100/24 .095 2.40 .085 2.16 1.460 37.08 2200 3274
MHV-5-535 535 271.2 1325/24 .095 2.40 .090 2.29 1.560 39.62 2550 3795
MHV-5-646 646 327.5 1600/24 .103 2.60 .095 2.42 1.682 42.67 3000 4465
MHV-5-777 777 393.8 1925/24 .103 2.60 .110 2.80 1.800 45.72 3500 5209
MHV-5-1111 1111 562.8 2750/24 .110 2.80 .110 2.80 2.060 52.32 4800 7143

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
24 hour: 281.851.1802 Fax: 281.209.3857
ISO9001
QSC3497
www.drakausa.com
111 BG_MHV5_100_101_2_00
Marine & Offshore
Product Specification J-121

TYPE N JACKET 5KV


IECIEEEUL
Conductor
BOSTRIG MHV-5B CABLE Soft annealed tinned copper.
Stranding as shown in table below.
Single Conductor Power (Type N Jacket) Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
5 kV - Shielded - 100% or 133% Level EPR.

Armored Only Insulation


Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-121 and flame test in IEC 60332-3, cat
Application A, A/F.
Bostrig MHV-5B single conductor 5,000 volt shielded cables are suitable for use in Rating
commercial marine applications, MODUs, and platforms where flame retardant cables Listed by a Nationally Recognized Testing Lab (ETL) in confor-
having excellent physical and electrical properties are required. The cables have excellent mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. 2001. Type approved by DNV, ABS and LRS.

1/c- 5 kV Shielded - 100% or 133% Level 170


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-5B-8 8 7.57 37/24 .090 2.29 .060 1.53 .720 18.29 380 566
MHV-5B-6 6 12.5 61/24 .090 2.29 .060 1.53 .780 19.81 450 670
MHV-5B-5 5 18.6 91/24 .090 2.29 .060 1.53 .810 20.57 510 759
MHV-5B-4 4 21.5 105/24 .090 2.29 .060 1.53 .850 21.59 550 818
MHV-5B-2 2 30.7 150/24 .090 2.29 .060 1.53 .910 23.11 650 967
MHV-5B-1 1 46.0 225/24 .090 2.29 .080 2.03 1.010 25.65 840 1250
MHV-5B-1/0 1/0 56.3 275/24 .090 2.29 .080 2.03 1.060 26.92 940 1399
MHV-5B-2/0 2/0 66.5 325/24 .090 2.29 .080 2.03 1.080 27.43 1020 1518
MHV-5B-3/0 3/0 92.1 450/24 .095 2.40 .080 2.03 1.190 30.23 1270 1890
MHV-5B-4/0 4/0 112.6 550/24 .095 2.40 .080 2.03 1.230 31.24 1430 2128
MHV-5B-262 262 133.0 650/24 .095 2.40 .080 2.03 1.280 32.51 1620 2411
MHV-5B-313 313 158.6 775/24 .095 2.40 .080 2.03 1.370 34.80 1840 2738
MHV-5B-373 373 189.3 925/24 .095 2.40 .080 2.03 1.440 36.58 2150 3200
MHV-5B-444 444 225.1 1100/24 .095 2.40 .085 2.16 1.520 38.61 2450 3646
MHV-5B-535 535 271.2 1325/24 .095 2.40 .090 2.16 1.620 41.15 2850 4241
MHV-5B-646 646 327.5 1600/24 .103 2.60 .095 2.42 1.740 44.20 3300 4911
MHV-5B-777 777 393.8 1925/24 .103 2.60 .110 2.80 1.860 47.25 3850 5729

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV5B_170_2_00
112
Marine & Offshore
Product Specification J-121
TYPE N JACKET 5KV

IECIEEEUL
Conductor
BOSTRIG MHV-5BS CABLE Soft annealed tinned copper per.
Stranding as shown in table below.
Single Conductor Power (Type N Jacket & Sheath) Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level EPR.

Armored and Sheathed Insulation


Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the metallic braid shield and outer
sheath over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.
Armor
Braided Bronze in accordance with IEEE 45-1998 & 1993 (draft).

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-121, and flame test in
Application IEC 60332-3, cat A, A/F.
Bostrig MHV-5BS single conductor 5,000 volt shielded cables are suitable for use in Rating
commercial marine applications, MODUs, and platforms where flame retardant cables Listed by a Nationally Recognized Testing Lab (ETL) in conformance
having excellent physical and electrical properties are required. The cables have excellent to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these approved by DNV, ABS and LRS.
cables can be supplied without the sheath over the armor.

1/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 101


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-5BS-8 8 7.57 37/24 .090 2.29 .060/.060 1.53/1.53 .840 21.34 470 700
MHV-5BS-6 6 12.5 61/24 .090 2.29 .060/.080 1.53/2.03 .940 23.88 580 863
MHV-5BS-5 5 18.6 91/24 .090 2.29 .060/.080 1.53/2.03 .970 24.64 650 967
MHV-5BS-4 4 21.5 105/24 .090 2.29 .060/.080 1.53/2.03 1.010 25.65 700 1042
MHV-5BS-2 2 30.7 150/24 .090 2.29 .060/.080 1.53/2.03 1.080 27.43 800 1191
MHV-5BS-l 1 46.0 225/24 .090 2.29 .080/.080 2.03/2.03 1.170 29.72 1010 1503
MHV-5BS-l/0 1/0 56.3 275/24 .090 2.29 .080/.080 2.03/2.03 1.220 30.99 1120 1667
MHV-5BS-2/0 2/0 66.5 325/24 .090 2.29 .080/.080 2.03/2.03 1.240 31.50 1210 1801
MHV-5BS-3/0 3/0 92.1 450/24 .095 2.40 .080/.080 2.03/2.03 1.350 34.29 1470 2188
MHV-5BS-4/0 4/0 112.6 550/24 .095 2.40 .080/.080 2.03/2.03 1.390 35.31 1630 2426
MHV-5BS-262 262 133.0 650/24 .095 2.40 .080/.080 2.03/2.03 1.440 36.58 1850 2753
MHV-5BS-313 313 158.6 775/24 .095 2.40 .080/.080 2.03/2.03 1.530 38.86 2100 3125
MHV-5BS-373 373 189.3 925/24 .095 2.40 .080/.080 2.03/2.03 1.600 40.64 2400 3572
MHV-5BS-444 444 225.1 1100/24 .095 2.40 .085/.080 2.16/2.03 1.690 42.93 2700 4018
MHV-5BS-535 535 271.2 1325/24 .095 2.40 .090/.110 2.29/2.03 1.840 46.74 3200 4762
MHV-5BS-646 646 327.5 1600/24 .103 2.60 .095/.110 2.42/2.80 1.960 49.78 3700 5506
MHV-5BS-777 777 393.8 1925/24 .103 2.60 .110/.110 2.80/2.80 2.090 53.09 4300 6399
MHV-5BS-l111 1111 562.8 2750/24 .110 2.80 .110/.110 2.80/2.80 2.340 59.44 5700 8483

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV5_100_101_2_00
113
Marine & Offshore
Product Specification J-122
IECIEEEUL
Conductor
BOSTRIG MHV-8 CABLE Soft annealed tinned copper.
Stranding as shown in table below.
Single Conductor Power (Type N Jacket)
Conductor Shield
8 kV (IEC 3.6/6 kV) Shielded - 100% Level Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
Unarmored Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.
Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-122 and
Flame test in IEC 60332-3, cat A, A/F.

TYPE N JACKET 8KV


Application Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Bostrig MHV-8 single conductor 8,000 volt shielded cables are suitable for use in mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
commercial marine applications, MODUs, and platforms where flame retardant cables 2001. Type approved by DNV, ABS and LRS.
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 102


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-8-6 6 12.5 61/24 .118 3.00 .060 1.53 .770 19.56 370 551
MHV-8-5 5 18.6 91/24 .118 3.00 .060 1.53 .810 20.57 430 640
MHV-8-4 4 21.5 105/24 .118 3.00 .060 1.53 .830 21.08 470 700
MHV-8-2 2 30.7 150/24 .118 3.00 .080 2.03 .930 23.62 590 878
MHV-8-1 1 46.0 225/24 .118 3.00 .080 2.03 .990 25.15 730 1086
MHV-8-1/0 1/0 56.3 275/24 .118 3.00 .080 2.03 1.050 26.67 820 1220
MHV-8-2/0 2/0 66.5 325/24 .118 3.00 .080 2.03 1.060 26.92 900 1339
MHV-8-3/0 3/0 92.1 450/24 .118 3.00 .080 2.03 1.170 29.72 1150 1711
MHV-8-4/0 4/0 112.6 550/24 .118 3.00 .080 2.03 1.220 30.99 1300 1935
MHV-8-262 262 133.0 650/24 .118 3.00 .080 2.03 1.270 32.26 1450 2158
MHV-8-313 313 158.6 775/24 .118 3.00 .080 2.03 1.360 34.54 1700 2530
MHV-8-373 373 189.3 925/24 .118 3.00 .085 2.16 1.440 36.58 1950 2902
MHV-8-444 444 225.1 1100/24 .118 3.00 .085 2.16 1.500 38.10 2250 3348
MHV-8-535 535 271.2 1325/24 .118 3.00 .090 2.29 1.600 40.64 2600 3869
MHV-8-646 646 327.5 1600/24 .118 3.00 .110 2.80 1.740 44.20 3100 4613
MHV-8-777 777 393.8 1925/24 .118 3.00 .110 2.80 1.840 46.74 3600 5357
MHV-8-1111 1111 562.8 2750/24 .118 3.20 .110 2.80 2.090 53.09 4900 7292

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV8_102_103_2_00
114
Marine & Offshore
Product Specification J-123
IECIEEEUL
Conductor
BOSTRIG MHV-8 CABLE Soft annealed tinned copper.
Stranding as shown in table below.
Single Conductor Power (Type N Jacket) Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
8 kV (IEC 6/10 kV) Shielded - 133% Level EPR.

Unarmored Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-123 and
Flame test in IEC 60332-3, cat A, A/F.

TYPE N JACKET 8KV


Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance
Application to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
Bostrig MHV-8 single conductor 8,000 volt shielded cables are suitable for use in approved by DNV, ABS and LRS.
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c - 8 kV (IEC 6/10 kv) Shielded - 133% Level 104


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-8-5 5 18.6 91/24 .140 3.56 .080 2.03 .890 22.61 510 759
MHV-8-4 4 21.5 105/24 .140 3.56 .080 2.03 .920 23.37 540 804
MHV-8-2 2 30.7 150/24 .140 3.56 .080 2.03 .980 24.89 640 952
MHV-8-1 1 46.0 225/24 .140 3.56 .080 2.03 1.050 26.67 770 1146
MHV-8-1/0 1/0 56.3 275/24 .140 3.56 .080 2.03 1.100 27.94 865 1287
MHV-8-2/0 2/0 66.5 325/24 .140 3.56 .080 2.03 1.120 28.45 950 1414
MHV-8-3/0 3/0 92.1 450/24 .140 3.56 .080 2.03 1.220 30.99 1200 1786
MHV-8-4/0 4/0 112.6 550/24 .140 3.56 .080 2.03 1.280 32.51 1350 2009
MHV-8-262 262 133.0 650/24 .140 3.56 .080 2.03/ 1.350 34.29 1550 2307
MHV-8-313 313 158.6 775/24 .140 3.56 .085 2.16 1.420 36.07 1750 2604
MHV-8-373 373 189.3 925/24 .140 3.56 .085 2.16 1.480 37.59 2000 2976
MHV-8-444 444 225.1 1100/24 .140 3.56 .090 2.29/ 1.560 39.62 2300 3423
MHV-8-535 535 271.2 1325/24 .140 3.56 .090 2.29 1.650 41.91 2650 3944
MHV-8-646 646 327.5 1600/24 .140 3.56 .110 2.80 1.800 45.72 3150 4688
MHV-8-777 777 393.8 1925/24 .140 3.56 .110 2.80 1.910 48.51 3700 5506
MHV-8-1111 1111 562.8 2750/24 .140 3.56 .110 2.80 2.130 54.10 4950 7366

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV8_104_105_2_00
115
Marine & Offshore
Product Specification J-122
IECIEEEUL
Conductor
BOSTRIG MHV-8B CABLE Soft annealed tinned copper.
Stranding as shown in table below.
Single Conductor Power (Type N Jacket) Conductor Shield
8 kV - Shielded - 100% Level Semi-conducting tape with extruded thermosetting semi-conduct-
ing
EPR.
Armored Only
Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993
(draft), ICEA S-68-516, UL 1072, J-122 and flame test in IEC

TYPE N JACKET 8KV


Application 60332-3, cat A, A/F.
Bostrig MHV-8B single conductor 8,000 volt shielded cables are suitable for use in Rating
commercial marine applications, MODUs, and platforms where flame retardant cables Listed by a Nationally Recognized Testing Lab (ETL) in confor-
having excellent physical and electrical properties are required. The cables have excellent mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. 2001. Type approved by DNV, ABS and LRS.

1/c - 8 kV Shielded - 100% Level 172


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-8B-6 6 12.5 61/24 .118 3.00 .060 1.53 .830 21.08 500 744
MHV-8B-5 5 18.6 91/24 .118 3.00 .060 1.53 .870 22.10 560 833
MHV-8B-4 4 21.5 105/24 .118 3.00 .065 1.53 .890 22.61 600 893
MHV-8B-2 2 30.7 150/24 .118 3.00 .080 2.03 .990 25.15 730 1086
MHV-8B-1 1 46.0 225/24 .118 3.00 .080 2.03 1.050 26.67 880 1309
MHV-8B-l/0 1/0 56.3 275/24 .118 3.00 .080 2.03 1.110 28.19 990 1473
MHV-8B-2/0 2/0 66.5 325/24 .118 3.00 .080 2.03 1.120 28.45 1070 1592
MHV-8B-3/0 3/0 92.1 450/24 .118 3.00 .080 2.03 1.230 31.24 1350 2009
MHV-8B-4/0 4/0 112.6 550/24 .118 3.00 .080 2.03 1.280 32.51 1550 2307
MHV-8B-262 262 133.0 650/24 .118 3.00 .080 2.03 1.330 33.78 1700 2530
MHV-8B-313 313 158.6 775/24 .118 3.00 .080 2.03 1.420 36.07 1950 2902
MHV-8B-373 373 189.3 925/24 .118 3.00 .085 2.16 1.500 38.10 2200 3274
MHV-8B-444 444 225.1 1100/24 .118 3.00 .085 2.16 1.560 39.62 2500 3720
MHV-8B-535 535 271.2 1325/24 .118 3.00 .090 2.29 1.660 42.17 2900 4316
MHV-8B-646 646 327.5 1600/24 .118 3.00 .110 2.80 1.800 45.72 3400 5060
MHV-8B-777 777 393.8 1925/24 .118 3.00 .110 2.80 1.900 48.26 3900 5804
MHV-8B-1111 1111 562.8 2750/24 .126 3.20 .110 2.80 2.150 54.61 5300 7887

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225
ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV8B_172_2_00
116
Marine & Offshore
Product Specification J-123
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV-8B CABLE Stranding as shown in table below.

Conductor Shield
Single Conductor Power (Type N Jacket) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
8 kV - Shielded - 133% Level Insulation
Armored Only Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.
Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-123 and flame test in IEC 60332-3, cat
TYPE N JACKET 8KV

A, A/F.
Rating
Application Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Bostrig MHV-8B single conductor 8,000 volt shielded cables are suitable for use in mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
commercial marine applications, MODUs, and platforms where flame retardant cables 2001. Type approved by DNV, ABS and LRS.
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

1/c 8 kV Shielded - l33% Level 173


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-8B-5 5 18.6 91/24 .140 3.56 .080 2.03 .950 24.13 650 967
MHV-8B-4 4 21.5 105/24 .140 3.56 .080 2.03 .980 24.89 680 1012
MHV-8B-2 2 30.7 150/24 .140 3.56 .080 2.03 1.040 26.42 790 1176
MHV-8B-1 1 46.0 225/24 .140 3.56 .080 2.03 1.110 28.19 940 1399
MHV-8B-1/0 1/0 56.3 275/24 .140 3.56 .080 2.03 1.160 29.46 1050 1563
MHV-8B-2/0 2/0 66.5 325/24 .140 3.56 .080 2.03 1.180 29.97 1150 1711
MHV-8B-3/0 3/0 92.1 450/24 .140 3.56 .080 2.03 1.280 32.51 1450 2158
MHV-8B-4/0 4/0 112.6 550/24 .140 3.56 .080 2.03 1.340 34.04 1600 2381
MHV-8B-262 262 133.0 650/24 .140 3.56 .080 2.03 1.410 35.81 1800 2679
MHV-8B-313 313 158.6 775/24 .140 3.56 .085 2.16 1.480 37.59 2050 3051
MHV-8B-373 373 189.3 925/24 .140 3.56 .085 2.16 1.540 39.12 2300 3423
MHV-8B-444 444 225.1 1100/24 .140 3.56 .090 2.29 1.620 41.15 2600 3869
MHV-8B-535 535 271.2 1325/24 .140 3.56 .090 2.29 1.710 43.43 2950 4390
MHV-8B-646 646 327.5 1600/24 .140 3.56 .110 2.80 1.860 47.24 3500 5209
MHV-8B-777 777 393.8 1925/24 .140 3.56 .110 2.80 1.970 50.04 4050 6027
MHV-8B-1111 1111 562.8 2750/24 .140 3.56 .110 2.80 2.190 55.63 5350 7962

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV8B_173_2_00
117
Marine & Offshore
Product Specification J-122
IECIEEEUL
Conductor
BOSTRIG MHV-8BS CABLE Soft annealed tinned copper.
Stranding as shown in table below.

Single Conductor Power (Type N Jacket & Sheath) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
8 kV (IEC 3.6/6 kV) Shielded - 100% Level EPR.

Armored and Sheathed Insulation


Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the metallic braid shield and outer
sheath over the armor are flame retardant, heavy duty artic
Neoprene. Thickness as shown in table below.

Armor
Braided Bronze.
Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
TYPE N JACKET 8KV

IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-122 and
Flame test in IEC 60332-3, cat A, A/F.
Application
Bostrig MHV-8BS single conductor 5,000 volt shielded cables are suitable for use in Rating
commercial marine applications, MODUs, and platforms where flame retardant cables Listed by a Nationally Recognized Testing Lab (ETL) in conformance
having excellent physical and electrical properties are required. The cables have excellent to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these approved by DNV, ABS and LRS.
cables can be supplied without the sheath over the armor.

1/c 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 103


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-8BS-6 6 12.5 61/24 .118 3.00 .060/.080 1.53/2.03 .990 25.15 640 952
MHV-8BS-5 5 18.6 91/24 .118 3.00 .060/.080 1.53/2.03 1.030 26.16 720 1071
MHV-8BS-4 4 21.5 105/24 .118 3.00 .060/.080 1.53/2.03 1.060 26.92 760 1131
MHV-8BS-2 2 30.7 150/24 .118 3.00 .080/.080 2.03/2.03 1.160 29.46 920 1369
MHV-8BS-1 1 46.0 225/24 .118 3.00 .080/.080 2.03/2.03 1.220 30.99 1100 1637
MHV-8BS-l/0 1/0 56.3 275/24 .118 3.00 .080/.080 2.03/2.03 1.270 32.26 1200 1786
MHV-8BS-2/0 2/0 66.5 325/24 .118 3.00 .080/.080 2.03/2.03 1.290 32.77 1270 1890
MHV-8BS-3/0 3/0 92.1 450/24 .118 3.00 .080/.080 2.03/2.03 1.390 35.31 1550 2307
MHV-8BS-4/0 4/0 112.6 550/24 .118 3.00 .080/.080 2.03/2.03 1.440 36.58 1750 2604
MHV-8BS-262 262 133.0 650/24 .118 3.00 .080/.080 2.03/2.03 1.490 37.85 1900 2828
MHV-8BS-313 313 158.6 775/24 .118 3.00 .080/.080 2.03/2.03 1.580 40.13 2200 3274
MHV-8BS-373 373 189.3 925/24 .118 3.00 .085/.080 2.16/2.03 1.650 41.91 2500 3720
MHV-8BS-444 444 225.1 1100/24 .118 3.00 .085/.080 2.16/2.03 1.780 45.21 2900 4316
MHV-8BS-535 535 271.2 1325/24 .118 3.00 .090/.110 2.29/2.80 1.880 47.75 3300 4911
MHV-8BS-646 646 327.5 1600/24 .118 3.00 .110/.110 2.80/2.80 2.030 51.56 3800 5655
MHV-8BS-777 777 393.8 1925/24 .118 3.00 .110/.110 2.80/2.80 2.130 54.10 4350 6474
MHV-8BS-1111 1111 562.8 2750/24 .118 3.20 .110/.110 2.80/2.80 2.370 60.20 5750 8557

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV8_102_103_2_00
118
Marine & Offshore
Product Specification J-123
IECIEEEUL
Conductor
BOSTRIG MHV-8BS CABLE Soft annealed tinned copper.
Stranding as shown in table below.
Single Conductor Power (Type N Jacket & Sheath) Conductor Shield
8 kV (IEC 6/10 kV) Shielded - 133% Level Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
Armored and Sheathed Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the metallic braid shield and outer
sheath over the annor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.
Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
TYPE N JACKET 8KV

IEEE 45-1998 & 1993 (draft), ICEA 5-68-516, UL 1072, J-123 and
Application Flame test in IEC 60332-3, cat A, A/F.
Bostrig MHV-8BS single conductor 8,000 volt shielded cables are suitable for use in Rating
commercial marine applications, MODUs, and platforms where flame retardant cables Listed by a Nationally Recognized Testing Lab (ETL) in conformance
having excellent physical and electrical properties are required. The cables have excellent to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these approved by DNV, ABS and LRS.
cables can be supplied without the sheath over the armor.

1/c - 8 kV (IEC 6/10 kv) Shielded - 133% Level 105


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV-8BS-5 5 18.6 91/24 .140 3.56 .080/.080 2.03/2.03 1.120 28.45 810 1205
MHV-8BS-4 4 21.5 105/24 .140 3.56 .080/.080 2.03/2.03 1.050 29.21 860 1280
MHV-8BS-2 2 30.7 150/24 .140 3.56 .080/.080 2.03/2.03 1.210 30.73 980 1458
MHV-8BS-1 1 46.0 225/24 .140 3.56 .080/.080 2.03/2.03 1.270 32.26 1150 1711
MHV-8BS-1/0 1/0 56.3 275/24 .140 3.56 .080/.080 2.03/2.03 1.320 33.53 1250 1860
MHV-8BS-2/0 2/0 66.5 325/24 .140 3.56 .080/.080 2.03/2.03 1.340 34.04 1330 1979
MHV-8BS-3/0 3/0 92.1 450/24 .140 3.56 .080/.080 2.03/2.03 1.440 36.58 1650 2455
MHV-8BS-4/0 4/0 112.6 550/24 .140 3.56 .080/.080 2.03/2.03 1.500 38.10 1820 2708
MHV-8BS-262 262 133.0 650/24 .140 3.56 .080/.080 2.03/2.03 1.570 39.88 2030 3021
MHV-8BS-313 313 158.6 775/24 .140 3.56 .085/.080 2.16/2.03 1.640 41.66 2300 3423
MHV-8BS-373 373 189.3 925/24 .140 3.56 .085/.110 2.16/2.80 1.770 44.96 2650 3944
MHV-8BS-444 444 225.1 1100/24 .140 3.56 .090/.110 2.29/2.80 1.850 46.99 3000 4465
MHV-8BS-535 535 271.2 1325/24 .140 3.56 .090/.110 2.29/2.80 1.940 49.28 3400 5060
MHV-8BS-646 646 327.5 1600/24 .140 3.56 .110/.110. 2.80/2.80 2.080 52.83 3900 5804
MHV-8BS-777 777 393.8 1925/24 .140 3.56 .110/.110 2.80/2.80 2.190 55.63 4500 6697
MHV-8BS-1111 1111 562.8 2750/24 .140 3.56 .110/.110 2.80/2.80 2.410 61.21 5850 8706

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV8_104_105_2_00
119
Marine & Offshore
Product Specification J-129
IIECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.
BOSTRIG MHV3-15 CABLE Conductor Shield
Three Conductor Power (Type N Jacket) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
15 kV (IEC 12/20 kV) Shielded - 133% Level Insulation
Extruded thermosetting EPR, 90C-Type E.
Unarmored Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.
Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.
Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-129, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Application 2001. Type approved by DNV, ABS and LRS.
Bostrig MHV3-15 three conductor 15,000 volt shielded cables are suitable for use in commer-
cial marine applications, MODUs, and platforms where flame retardant cables having excellent
physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed
in the interstices.

3/c - 15 kV (IEC 12/20 kV) Shielded - 133% Level 118


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-15-2 2 30.7 150/24 .220 5.59 .115 2.92 2.330 59.18 2600 3869
MHV3-15-1 1 46.0 225/24 .220 5.59 .120 3.05 2.470 62.74 3100 4613
MHV3-15-1/0 1/0 56.3 275/24 .220 5.59 .125 3.18 2.590 65.79 3500 5209
MHV3-15-2/0 2/0 66.5 325/24 .220 5.59 .130 3.30 2.650 67.31 3750 5581
MHV3-15-3/0 3/0 92.1 450/24 .220 5.59 .140 3.56 2.930 74.42 4750 7069
MHV3-15-4/0 4/0 112.6 550/24 .220 5.59 .145 3.68 3.050 77.47 5300 7887
MHV3-15-262 262 133.0 650/24 .220 5.59 .145 3.68 3.160 80.26 5850 8706
MHV3-15-313 313 158.6 775/24 .220 5.59 .155 3.94 3.320 84.33 6600 9822
MHV3-15-373 373 189.3 925/24 .220 5.59 .160 4.06 3.470 88.14 7450 11087
MHV3-15-444 444 225.1 1100/24 .220 5.59 .165 4.19 3.640 92.46 8450 12575 TYPE N JACKET 15KV
MHV3-15-535 535 271.2 1325/24 .220 5.59 .170 4.32 3.850 97.79 9700 14435
MHV3-15-646 646 327.5 1600/24 .220 5.59 .185 4.76 4.140 105.16 11300 16816
MHV3-15-777 777 393.8 1925/24 .220 5.59 .190 4.83 4.330 109.98 12950 19271
MHV3-15-1111 1111 562.8 2750/24 .220 5.59 .210 5.33 4.850 123.19 17300 25745

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-15_118_119_2_00
120
Marine & Offshore
Product Specification J-128
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-15 CABLE Stranding as shown in table below.
Conductor Shield
Three Conductor Power (Type N Jacket) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
15 kV (IEC 8.7/15 kV) Shielded - 100% Level Insulation
Unarmored Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.
Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cabled core.
Thickness as shown in table below.
Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-128, and
flame test in IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Application mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Bostrig MHV3-15 three conductor 15,000 volt shielded cables are suitable for use in commercial 2001. Type approved by DNV, ABS and LRS.
marine applications, MODUs, and platforms where flame retardant cables having excellent
physical and electrical properties are required. The cables have excellent resistance to oils, abra-
sion, petrochemical fluids, moisture, and sunlight. When required, these cables can be supplied
without the sheath over the armor. Cables are also available with either a fully insulated ground-
ing conductor or an un-insulated grounding conductor evenly distributed in the interstices.

3/c 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 116


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-15-2 2 30.7 150/24 .177 4.50 .110 2.80 2.110 53.59 2300 3423
MHV3-15-1 1 46.0 225/24 .177 4.50 .115 2.92 2.260 57.40 2790 4152
MHV3-15-1/0 1/0 56.3 275/24 .177 4.50 .120 3.05 2.390 60.71 3200 4643
MHV3-15-2/0 2/0 66.5 325/24 .177 4.50 .120 3.05 2.420 61.47 3370 5015
MHV3-15-3/0 3/0 92.1 450/24 .177 4.50 .130 3.30 2.710 68.83 4300 6399
MHV3-15-4/0 4/0 112.6 550/24 .177 4.50 .140 3.56 2.840 72.14 4900 7292
MHV3-15-262 262 133.0 650/24 .177 4.50 .140 3.56 2.940 74.68 5400 8036
MHV3-15-313 313 158.6 775/24 .177 4.50 .145 3.68 3.100 78.74 6100 9078
MHV3-15-373 373 189.3 925/24 .177 4.50 .150 3.81 3.260 82.80 6900 10268 TYPE N JACKET 15KV
MHV3-15-444 444 225.1 1100/24 .177 4.50 .155 3.94 3.420 86.87 7900 11756
MHV3-15-535 535 271.2 1325/24 .177 4.50 .165 4.19 3.640 92.46 9100 13542
MHV3-15-646 646 327.5 1600/24 .177 4.50 .175 4.45 3.870 98.30 10600 15775
MHV3-15-777 777 393.8 1925/24 .177 4.50 .185 4.70 4.120 104.65 12300 18304
MHV3-15-1111 1111 562.8 2750/24 .177 4.50 .200 5.08 4.620 117.35 16600 24703

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-15_116_117_2_00
121
Marine & Offshore
Product Specification J-128
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-15B CABLE Stranding as shown in table below.

Three Conductor Power (Type N Jacket) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
15 kV - Shielded - 100% Level
Insulation
Armored Only Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.
Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.
Armor
Braided Bronze.
Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-128 and flame test in IEC 60332-3, cat
A, A/F.
Rating
Application Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Bostrig MHV3-15B single conductor 15,000 volt shielded cables are suitable for use in com- mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
mercial marine applications, MODUs, and platforms where flame retardant cables having 2001. Type approved by DNV, ABS and LRS.
excellent physical and electrical properties are required. The cables have excellent resistance to
oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with
either a fully insulated grounding conductor or an un-insulated grounding conductor evenly
distributed in the interstices.

3/c 15 kV Shielded - 100% Level 178


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-15B-2 2 30.7 150/24 .177 4.50 .110 2.80 2.170 55.12 2660 3959
MHV3-15B-1 1 46.0 225/24 .177 4.50 .115 2.92 2.320 58.93 3200 4762
MHV3-15B-l/0 1/0 56.3 275/24 .177 4.50 .120 3.05 2.450 62.23 3550 5283
MHV3-15B-2/0 2/0 66.5 325/24 .177 4.50 .120 3.05 2.480 62.99 3800 5655
MHV3-15B-3/0 3/0 92.1 450/24 .177 4.50 .130 3.30 2.770 70.36 4800 7143
MHV3-15B-4/0 4/0 112.6 550/24 .177 4.50 .140 3.56 2.900 73.66 5400 8036
MHV3-15B-262 262 133.0 650/24 .177 4.50 .140 3.56 3.000 76.20 5950 8855
MHV3-15B-313 313 158.6 775/24 .177 4.50 .145 3.68 3.160 80.26 6700 9971
MHV3-15B-373 373 189.3 925/24 .177 4.50 .150 3.81 3.320 84.33 7550 11236 TYPE N JACKET 15KV
MHV3-15B-444 444 225.1 1100/24 .177 4.50 .155 3.94 3.480 88.39 8550 12724
MHV3-15B-535 535 271.2 1325/24 .177 4.50 .165 4.19 3.700 93.98 9800 14584
MHV3-15B-646 646 327.5 1600/24 .177 4.50 .175 4.45 3.930 99.82 11300 16816
MHV3-15B-777 777 393.8 1925/24 .177 4.50 .185 4.70 4.180 106.17 13100 19495
MHV3-15B-1111 1111 562.8 2750/24 .177 4.50 .200 5.08 4.680 118.87 17500 26042

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-15B_178_2_00
122
Marine & Offshore
Product Specification J-129
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-15B CABLE Stranding as shown in table below.

Conductor Shield
Three Conductor Power (Type N Jacket) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
15 kV - Shielded - 133% Level
Insulation
Armored Only Extruded thermosetting EPR, 90C-Type E.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-129 and flame test in IEC 60332-3, cat
A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Application mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Bostrig MHV3-15B three conductor 15,000 volt shielded cables are suitable for use in 2001. Type approved by DNV, ABS and LRS.
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight.

3/c 15 kV Shielded - 133% Level 179


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-15B-2 2 30.7 150/24 .220 5.59 .115 2.92 2.390 60.71 3010 4479
MHV3-15B-1 1 46.0 225/24 .220 5.59 .120 3.05 2.530 64.26 3550 5283
MHV3-15B-1/0 1/0 56.3 275/24 .220 5.59 .125 3.18 2.650 67.31 3950 5878
MHV3-15B-2/0 2/0 66.5 325/24 .220 5.59 .130 3.30 2.710 68.83 4250 6325
MHV3-15B-3/0 3/0 92.1 450/24 .220 5.59 .140 3.56 2.990 75.95 5250 7813
MHV3-15B-4/0 4/0 112.6 550/24 .220 5.59 .145 3.68 3.110 78.99 5850 8706
MHV3-15B-262 262 133.0 650/24 .220 5.59 .145 3.68 3.220 81.78 6400 9525
MHV3-15B-313 313 158.6 775/24 .220 5.59 .155 3.94 3.380 85.85 7200 10715
MHV3-15B-373 373 189.3 925/24 .220 5.59 .160 4.06 3.530 89.66 8100 12054
MHV3-15B-444 444 225.1 1100/24 .220 5.59 .165 4.19 3.700 93.98 9100 13542
TYPE N JACKET 15KV

MHV3-15B-535 535 271.2 1325/24 .220 5.59 .170 4.32 3.910 99.31 10400 15477
MHV3-15B-646 646 327.5 1600/24 .220 5.59 .185 4.76 4.200 106.68 12100 18007
MHV3-15B-777 777 393.8 1925/24 .220 5.59 .190 4.83 4.390 111.51 13800 20536
MHV3-15B-1111 1111 562.8 2750/24 .220 5.59 .210 5.33 4.910 124.71 18200 27084

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-15B_179_2_00
123
Marine & Offshore
Product Specification J-129
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-15BS CABLE Stranding as shown in table below.

Three Conductor Power (Type N Jacket & Sheath) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
15 kV (IEC 12/20 kV) Shielded - 133% Level EPR.
Insulation
Armored and Sheathed Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.
Jacket and Sheath
Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.
Armor
Braided Bronze.
Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-129, and flame test in
IEC 60332-3, cat A, A/F.
Application Rating
Bostrig MHV3-15BS three conductor 15,000 volt shielded cables are suitable for use in com- Listed by a Nationally Recognized Testing Lab (ETL) in confor-
mercial marine applications, MODUs, and platforms where flame retardant cables having mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
excellent physical and electrical properties are required. The cables have excellent resistance to 2001. Type approved by DNV, ABS and LRS.
oils, abrasion, petrochemical fluids, moisture, and sunlight. When required these cables can be
supplied without the sheath over the armor. Cables are also available with either a fully insu-
lated grounding conductor or an un-insulated grounding conductor evenly distributed in the
interstices.

3/c 15 kV (IEC 12/20 kV) Shielded - 133% Level 119


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-15BS-2 2 30.7 150/24 .220 5.59 .115/.110 2.92/2.80 2.600 66.04 3600 5357
MHV3-15BS-1 1 46.0 225/24 .220 5.59 .120/.110 3.05/2.80 2.750 69.85 4150 6176
MHV3-15BS-1/0 1/0 56.3 275/24 .220 5.59 .125/.140 3.18/3.56 2.930 74.42 4700 6994
MHV3-15BS-2/0 2/0 66.5 325/24 .220 5.59 .130/.140 3.30/3.56 2.970 75.44 5000 7441
MHV3-15BS-3/0 3/0 92.1 450/24 .220 5.59 .140/.140 3.56/3.56 3.260 82.85 6100 9078
MHV3-15BS-4/0 4/0 112.6 550/24 .220 5.59 .145/.140 3.68/3.56 3.380 85.85 6750 10045
MHV3-15BS-262 262 133.0 650/24 .220 5.59 .145/.140 3.68/3.56 3.480 88.39 7300 10864
MHV3-15BS-313 313 158.6 775/24 .220 5.59 .155/.140 3.94/3.56 3.650 92.71 8150 12129
TYPE N JACKET 15KV

MHV3-15BS-373 373 189.3 925/24 .220 5.59 .160/.140 4.06/3.56 3.810 96.77 9100 13542
MHV3-15BS-444 444 225.1 1100/24 .220 5.59 .165/.140 4.19/3.56 3.970 100.84 10200 15180
MHV3-15BS-535 535 271.2 1325/24 .220 5.59 .170/.140 4.32/3.56 4.180 106.17 11500 17114
MHV3-15BS-646 646 327.5 1600/24 .220 5.59 .185/.140 4.76/3.56 4.470 113.54 13300 19793
MHV3-15BS-777 777 393.8 1925/24 .220 5.59 .190/.140 4.83/3.56 4.670 118.62 15000 22322
MHV3-15BS-1111 1111 562.8 2750/24 .220 5.59 .210/.140 5.33/3.56 5.190 131.83 19600 29168

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com
124 BG_MHV3-15_118_119_2_00
Marine & Offshore
Product Specification J-128
IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.
BOSTRIG MHV3-15BS CABLE Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
Three Conductor Power (Type N Jacket & Sheath) EPR.
15 kV (IEC 8.7/15 kV) Shielded - 100% Level Insulation
Extruded thermosetting EPR, 90C-Type E.
Armored and Sheathed Thickness as shown in table below.
Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.
Jacket and Sheath
Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.
Armor
Braided Bronze.
Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-128, and
flame test in IEC 60332-3, cat A, A/F.

Rating
Application Listed by a Nationally Recognized Testing Lab (ETL) in confor-
Bostrig MHV3-15BS three conductor 15,000 volt shielded cables are suitable for use in mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
commercial marine applications, MODUs, and platforms where flame retardant cables 2001. Type approved by DNV, ABS and LRS.
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these
cables can be supplied without the sheath over the armor. Cables are also available with either
a fully insulated grounding conductor or an un-insulated grounding conductor evenly distrib-
uted in the interstices.

3/c 15 kV (IEC 8.7/15 kV) Shielded - 100% Level 117


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-15BS-2 2 30.7 150/24 .177 4.50 .110/.110 2.80/2.80 2.400 60.96 3150 4688
MHV3-15BS-1 1 46.0 225/24 .177 4.50 .115/.110 2.92/2.80 2.540 64.52 3700 5506
MHV3-15BS-1/0 1/0 56.3 275/24 .177 4.50 .120/.110 3.05/2.80 2.670 67.82 4100 6102
MHV3-15BS-2/0 2/0 66.5 325/24 .177 4.50 .120/.110 3.05/2.80 2.710 68.83 4400 6548
MHV3-15BS-3/0 3/0 92.1 450/24 .177 4.50 .130/.140 3.30/2.80 3.050 77.47 5600 8334
MHV3-15BS-4/0 4/0 112.6 550/24 .177 4.50 .140/.140 3.56/3.56 3.180 80.77 6200 9226
MHV3-15BS-262 262 133.0 650/24 .177 4.50 .140/.140 3.56/3.56 3.290 83.57 6800 10120
MHV3-15BS-313 313 158.6 775/24 .177 4.50 .145/.140 3.68/3.56 3.440 87.38 7600 11310
TYPE N JACKET 15KV

MHV3-15BS-373 373 189.3 925/24 .177 4.50 .150/.140 3.81/3.56 3.600 91.44 8500 12649
MHV3-15BS-444 444 225.1 1100/24 .177 4.50 .155/.140 3.94/3.56 3.760 95.50 9500 14138
MHV3-15BS-535 535 271.2 1325/24 .177 4.50 .165/.140 4.19/3.56 3.980 101.09 10800 16072
MHV3-15BS-646 646 327.5 1600/24 .177 4.50 .175/.140 4.45/3.56 4.210 106.93 12400 18453
MHV3-15BS-777 777 393.8 1925/24 .177 4.50 .185/.140 4.70/3.56 4.470 113.54 14300 21281
MHV3-15BS-1111 1111 562.8 2750/24 .177 4.50 .200/.140 5.08/3.56 4.970 126.24 18700 27829

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-15_116_117_2_00
125
Marine & Offshore
Product Specification J-125
TYPE N JACKET 5KV

IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-5 CABLE Stranding as shown in table below.

Conductor Shield
Three Conductor Power (Type N Jacket) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level
Insulation
Unarmored Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
1993 (draft), ICEA S-68-516, UL 1072, J-125, and flame test in
IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-
mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Application 2001. Type approved by DNV, ABS and LRS.
Bostrig MHV3-5 three conductor 5,000 volt shielded cables are suitable for use in
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also avail-
able with either a fully insulated grounding conductor or an un-insulated grounding conductor
evenly distributed in the interstices.

3/c - 5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level 110


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-5-8 8 7.57 37/24 .090 2.29 .080 2.03 1.300 33.02 850 1265
MHV3-5-6 6 12.5 61/24 .090 2.29 .085 2.16 1.430 36.32 1070 1592
MHV3-5-5 5 18.6 91/24 .090 2.29 .085 2.16 1.510 38.35 1260 1875
MHV3-5-4 4 21.5 105/24 .090 2.29 .090 2.29 1.580 40.13 1380 2054
MHV3-5-2 2 30.7 150/24 .090 2.29 .110 2.80 1.750 44.45 1730 2575
MHV3-5-1 1 46.0 225/24 .090 2.29 .110 2.80 1.880 47.75 2160 3214
MHV3-5-1/0 1/0 56.3 275/24 .090 2.29 .110 2.80 1.990 50.55 2450 3646
MHV3-5-2/0 2/0 66.5 325/24 .090 2.29 .110 2.80 2.030 51.56 2700 4018
MHV3-5-3/0 3/0 92.1 450/24 .095 2.40 .115 2.92 2.280 57.91 3500 5210
MHV3-5-4/0 4/0 112.6 550/24 .095 2.40 .120 3.05 2.400 60.96 4000 5953
MHV3-5-262 262 133.0 650/24 .095 2.40 .125 3.18 2.520 64.01 4500 6697
MHV3-5-313 313 158.6 775/24 .095 2.40 .130 3.30 2.720 69.09 5300 7887
MHV3-5-373 373 189.3 925/24 .095 2.40 .140 3.56 2.880 73.15 6100 9078
MHV3-5-444 444 225.1 1100/24 .095 2.40 .145 3.68 3.040 77.22 7000 10417
MHV3-5-535 535 271.2 1325/24 .095 2.40 .150 3.81 3.260 82.55 8050 11980
MHV3-5-646 646 327.5 1600/24 .103 2.60 .160 4.06 3.520 89.41 9600 14286
MHV3-5-777 777 393.8 1925/24 .103 2.60 .170 4.32 3.730 94.74 11200 16667
MHV3-5-1111 1111 562.8 2750/24 .110 2.80 .190 4.83 4.320 109.73 15600 23215

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-5_110_111_2_00
126
Marine & Offshore
Product Specification J-125
TYPE N JACKET 5KV

IECIEEEUL
BOSTRIG MHV3-5B CABLE Conductor
Soft annealed tinned copper.
Three Conductor Power (Type N Jacket) Stranding as shown in table below.
5 kV - Shielded - 100% or 133% Level Conductor Shield
Semi-conducting tape with extruded thermosetting semi-conducting
Armored Only EPR.

Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the metallic braid shield.
Thickness as shown in table below.

Armor
Braided Bronze.
Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
Application ICEA S-68-5I6, UL 1072, J-125 and flame test in IEC 60332-3, cat
Bostrig MHV3-5B three conductor 5,000 volt shielded cables are suitable for use in A, A/F.
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent Rating
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also avail- Listed by a Nationally Recognized Testing Lab (ETL) in confor-
able with either a fully insulated grounding conductor or an un-insulated grounding conductor mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
evenly distributed in the interstices. 2001. Type approved by DNV, ABS and LRS.

3/c - 5 kV Shielded - 100% or 133% Level 175


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-5B-8 8 7.57 37/24 .090 2.29 .080 2.03 1.360 34.54 1090 1622
MHV3-5B-6 6 12.5 61/24 .090 2.29 .085 2.16 1.490 37.85 1330 1980
MHV3-5B-5 5 18.6 91/24 .090 2.29 .085 2.16 1.570 39.88 1530 2276
MHV3-5B-4 4 21.5 105/24 .090 2.29 .090 2.29 1.640 41.66 1670 2485
MHV3-5B-2 2 30.7 150/24 .090 2.29 .110 2.80 1.810 45.97 2030 3021
MHV3-5B-1 1 46.0 225/24 .090 2.29 .110 2.80 1.940 49.28 2500 3721
MHV3-5B-1/0 1/0 56.3 275/24 .090 2.29 .110 2.80 2.050 52.07 2800 4167
MHV3-5B-2/0 2/0 66.5 325/24 .090 2.29 .110 2.80 2.080 52.83 3050 4539
MHV3-5B-3/0 3/0 92.1 450/24 .095 2.40 .115 2.92 2.340 59.44 3900 5804
MHV3-5B-4/0 4/0 112.6 550/24 .095 2.40 .120 3.06 2.460 62.48 4450 6622
MHV3-5B-262 262 133.0 650/24 .095 2.40 .125 3.18 2.580 65.53 5000 7441
MHV3-5B-313 313 158.6 775/24 .095 2.40 .130 3.30 2.780 70.61 5800 8631
MHV3-5B-373 373 189.3 925/24 .095 2.40 .140 3.56 2.940 74.68 6600 9822
MHV3-5B-444 444 225.1 1100/24 .095 2.40 .145 3.68 3.100 78.74 7550 11236
MHV3-5B-535 535 271.2 1325/24 .095 2.40 .150 3.81 3.320 84.33 8750 13021
MHV3-5B-646 646 327.5 1600/24 .103 2.60 .160 4.06 3.580 90.93 10300 15328
MHV3-5B-777 777 393.8 1925/24 .103 2.60 .170 4.32 3.790 96.27 11900 17709
MHV3-5B-1111 1111 562.8 2750/24 .110 2.80 .190 4.83 4.380 111.25 16400 24406

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-5B_175_2_00
127
Marine & Offshore
Product Specification J-125

TYPE N JACKET 5KV


IECIEEEUL
BOSTRIG MHV3-5BS CABLE Conductor
Soft annealed tinned copper.
Three Conductor Power (Type N Jacket & Sheath) Stranding as shown in table below.

Conductor Shield
5 kV (IEC 1.8/3 kV) Shielded - 100% or 133% Level Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
Armored and Sheathed
Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the cable core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEEE 45-1998 &
Application 1993 (draft), ICEAS-68-516, UL 1072, J-125, and flame test in
IEC 60332-3, cat A, A/F.
Bostrig MHV3-5BS three conductor 5,000 volt shielded cables are suitable for use in
commercial marinc applications, MODUs, and platforms where flame retardant cables Rating
having excellent physical and electrical properties are required. The cables have excellent Listed by a Nationally Recognized Testing Lab (ETL) in confor-
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. When required, these mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
cables can be supplied without the sheath over the armor. Cables are also available with either a 2001. Type approved by DNV, ABS and LRS.
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed in
the interstices.

3/c - 5 kV (IEC 1.8/3 kV) Shielded - l00% or 133% Level 111


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-5BS-8 8 7.57 37/24 .090 2.29 .080/.080 2.03/2.03 1.520 38.61 1350 2009
MHV3-5BS-6 6 12.5 61/24 .090 2.29 .085/.080 2.16/2.03 1.650 41.91 1600 2381
MHV3-5BS-5 5 18.6 91/24 .090 2.29 .085/.110 2.16/2.80 1.800 45.72 1900 2828
MHV3-5BS-4 4 21.5 105/24 .090 2.29 .090/.110 2.29/2.80 1.870 47.54 2050 3051
MHV3-5BS-2 2 30.7 150/24 .090 2.29 .110/.110 2.80/2.80 2.030 51.56 2450 3646
MHV3-5BS-l 1 46.0 225/24 .090 2.29 .110/.110 2.80/2.80 2.160 54.86 2950 4390
MHV3-5BS-l/0 1/0 56.3 275/24 .090 2.29 .110/.110 2.80/2.80 2.280 57.91 3300 4911
MHV3-5BS-2/0 2/0 66.5 325/24 .090 2.29 .110/.110 2.80/2.80 2.320 58.93 3550 5283
MHV3-5BS-3/0 3/0 92.1 450/24 .095 2.40 .115/.110 2.92/2.80 2.560 65.02 4450 6622
MHV3-5BS-4/0 4/0 112.6 550/24 .095 2.40 .120/.110 3.05/2.80 2.680 68.07 5000 7441
MHV3-5BS-262 262 133.0 650/24 .095 2.40 .125/.110 3.18/2.80 2.860 72.64 5700 8483
MHV3-5BS-313 313 158.6 775/24 .095 2.40 .130/.140 3.30/3.56 3.060 77.72 6600 9822
MHV3-5BS-373 373 189.3 925/24 .095 2.40 .140/.140 3.56/3.56 3.220 81.79 7450 11087
MHV3-5BS-444 444 225.1 1100/24 .095 2.40 .145/.140 3.68/3.56 3.380 85.85 8450 12575
MHV3-5BS-535 535 271.2 1325/24 .095 2.40 .150/.140 3.81/3.56 3.590 91.19 9700 14435
MHV3-5BS-646 646 327.5 1600/24 .103 2.60 .160/.140 4.06/3.56 3.860 98.04 11300 16816
MHV3-5BS-777 777 393.8 1925/24 .103 2.60 .170/.140 4.32/3.56 4.070 103.38 13000 19346
MHV3-5BS-1111 1111 562.8 2750/24 .110 2.80 .190/.140 4.83/3.56 4.660 118.36 17600 26192

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857
QSC3497
www.drakausa.com BG_MHV3-5_110_111_2_00
128
Marine & Offshore
Product Specification J-126
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-8 CABLE Stranding as shown in table below.

Three Conductor Power (Type N Jacket) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
8 kV (IEC 3.6/6 kV) Shielded - 100% Level EPR.

Insulation
Unarmored Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.
Metallic Braid Shield
Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.
Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-126, and
flame test in IEC 60332-3, cat A, A/F.

Rating
Listed by a Nationally Recognized Testing Lab (ETL) in confor-

TYPE N JACKET 8KV


mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Application 2001. Type approved by DNV, ABS and LRS.
Bostrig MHV3-8 three conductor 8,000 volt shielded cables are suitable for use in commercial
marine applications, MODUs, and platforms where flame retardant cables having excellent
physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed
in the interstices.

3/c - 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 112


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-8-6 6 12.5 61/24 .118 3.00 .090 2.29 1.570 39.88 1230 1830
MHV3-8-5 5 18.6 91/24 .118 3.00 .090 2.29 1.650 41.91 1420 2113
MHV3-8-4 4 21.5 105/24 .118 3.00 .095 2.40 1.710 43.43 1560 2322
MHV3-8-2 2 30.7 150/24 .118 3.00 .110 2.80 1.870 47.50 1890 2813
MHV3-8-1 1 46.0 225/24 .118 3.00 .110 2.80 2.000 50.80 2340 3482
MHV3-8-1/0 1/0 56.3 275/24 .118 3.00 .110 2.80 2.110 53.59 2640 3929
MHV3-8-2/0 2/0 66.5 325/24 .118 3.00 .110 2.80 2.150 54.61 3900 4316
MHV3-8-3/0 3/0 92.1 450/24 .118 3.00 .120 3.05 2.400 60.96 3700 5506
MHV3-8-4/0 4/0 112.6 550/24 .118 3.00 .125 3.18 2.510 63.75 4200 6250
MHV3-8-262 262 133.0 650/24 .118 3.00 .130 3.30 2.630 66.80 4700 6994
MHV3-8-313 313 158.6 775/24 .118 3.00 .140 3.56 2.830 71.88 5550 8259
MHV3-8-373 373 189.3 925/24 .118 3.00 .145 3.56 2.990 75.95 6300 9375
MHV3-8-444 444 225.1 1100/24 .118 3.00 .145 3.68 3.150 80.01 7250 10789
MHV3-8-535 535 271.2 1325/24 .118 3.00 .155 3.94 3.360 85.34 8450 12575
MHV3-8-646 646 327.5 1600/24 .118 3.00 .165 4.19 3.590 91.19 9850 14658
MHV3-8-777 777 393.8 1925/24 .118 3.00 .170 4.32 3.800 96.52 11400 16965
MHV3-8-1111 1111 562.8 2750/24 .126 3.20 .195 4.95 4.400 111.76 15850 23587

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-8_112_113_2_00
129
Marine & Offshore
Product Specification J-127
IECIEEEUL
Conductor
BOSTRIG MHV3-8 CABLE Soft annealed tinned copper.
Stranding as shown in table below.

Three Conductor Power (Type N Jacket) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
8 kV (IEC 6/10 kV) Shielded - 133% Level EPR.

Unarmored Insulation
Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
Ajacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.
Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-127, and
flame test in IEC 60332-3, cat A, A/F.

Rating

TYPE N JACKET 8KV


Listed by a Nationally Recognized Testing Lab (ETL) in conformance
Application to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
Bostrig MHV3-8 three conductor 8,000 volt shielded cables are suitable for use in commercial approved by DNV, ABS and LRS.
marine applications, MODUs, and platforms where flame retardant cables having excellent
physical and electrical properties are required. The cables have excellent resistance to oils,
abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed
in the interstices.

3/c - 8 kV (IEC 6/10 kV) Shielded - 133% Level 114


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-8-5 5 18.6 91/24 .140 3.56 .110 2.80 1.780 45.21 1610 2396
MHV3-8-4 4 21.5 105/24 .140 3.56 .110 2.80 1.840 46.74 1730 2575
MHV3-8-2 2 30.7 150/24 .140 3.56 .110 2.80 1.960 49.78 2030 3021
MHV3-8-1 1 46.0 225/24 .140 3.56 .110 2.80 2.100 53.34 2470 3676
MHV3-8-1/0 1/0 56.3 275/24 .140 3.56 .115 2.92 2.210 56.13 2790 4152
MHV3-8-2/0 2/0 66.5 325/24 .140 3.56 .115 2.92 2.250 57.15 3040 4524
MHV3-8-3/0 3/0 92.1 450/24 .140 3.56 .125 3.18 2.500 63.50 3870 5759
MHV3-8-4/0 4/0 112.6 550/24 .140 3.56 .125 3.18 2.610 66.29 4380 6518
MHV3-8-262 262 133.0 650/24 .140 3.56 .135 3.43 2.780 70.61 5000 7440
MHV3-8-313 313 158.6 775/24 .140 3.56 .140 3.56 2.930 74.42 5750 8557
MHV3-8-373 373 189.3 925/24 .140 3.56 .145 3.68 3.090 78.49 6550 9748
MHV3-8-444 444 225.1 1100/24 .140 3.56 .150 3.81 3.250 82.55 7500 11161
MHV3-8-535 535 271.2 1325/24 .140 3.56 .160 4.06 3.470 88.14 8700 12947
MHV3-8-646 646 327.5 1600/24 .140 3.56 .165 4.19 3.690 93.73 10100 15030
MHV3-8-777 777 393.8 1925/24 .140 3.56 .175 4.45 3.950 100.33 11800 17560
MHV3-8-1111 1111 562.8 2750/24 .140 3.56 .195 4.95 4.460 113.28 16100 23959

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857
QSC3497
www.drakausa.com BG_MHV3-8_114_115_2_00
130
Marine & Offshore
Product Specification J-126
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-8B CABLE Stranding as shown in table below.

Three Conductor Power (Type N Jacket) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
8 kV - Shielded - 100% Level EPR.

Armored Only Insulation


Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core.
Thickness as shown in table below.
Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),

TYPE N JACKET 8KV


ICEA S-68-516, UL 1072, J-126 and flame test in IEC 60332-3, cat A,
A/F.
Application
Bostrig MHV3-8B three conductor 8,000 volt shielded cables are suitable for use in commer-
Rating
Listed by a Nationally Recognized Testing Lab (ETL) in conformance
cial marine applications, MODUs, and platforms where flame retardant cables having excel-
to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001. Type
lent physical and electrical properties are required. The cables have excellent resistance to oils, approved by DNV, ABS and LRS.
abrasion, petrochemical fluids, moisture, and sunlight. Cables are also available with either a
fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed
in the interstices.

3/c - 8 kV Shielded - 100% Level 176


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-8B-6 6 12.5 61/24 .118 3.00 .090 2.29 1.630 41.40 1510 2247
MHV3-8B-5 5 18.6 91/24 .118 3.00 .090 2.29 1.710 43.43 1720 2560
MHV3-8B-4 4 21.5 105/24 .118 3.00 .095 2.40 1.770 44.93 1870 2783
MHV3-8B-2 2 30.7 150/24 .118 3.00 .110 2.80 1.930 49.02 2250 3348
MHV3-8B-1 1 46.0 225/24 .118 3.00 .110 2.80 2.060 52.32 2700 4018
MHV3-8B-1/0 1/0 56.3 275/24 .118 3.00 .110 2.80 2.170 55.12 3050 4539
MHV3-8B-2/0 2/0 66.5 325/24 .118 3.00 .110 2.80 2.210 56.13 3300 4911
MHV3-8B-3/0 3/0 92.1 450/24 .118 3.00 .120 3.05 2.460 62.48 4150 6176
MHV3-8B-4/0 4/0 112.6 550/24 .118 3.00 .125 3.18 2.570 65.28 4700 6994
MHV3-8B-262 262 133.0 650/24 .118 3.00 .130 3.30 2.690 68.32 5200 7738
MHV3-8B-313 313 158.6 775/24 .118 3.00 .140 3.56 2.890 73.41 6050 9003
MHV3-8B-373 373 189.3 925/24 .118 3.00 .140 3.56 3.050 77.47 6850 10194
MHV3-8B-444 444 225.1 1100/24 .118 3.00 .145 3.68 3.210 81.53 7800 11607
MHV3-8B-535 535 271.2 1325/24 .118 3.00 .155 3.94 3.420 86.87 9050 13468
MHV3-8B-646 646 327.5 1600/24 .118 3.00 .165 4.19 3.650 92.71 10500 15626
MHV3-8B-777 777 393.8 1925/24 .118 3.00 .170 4.32 3.860 98.04 12100 18007
MHV3-8B-1111 1111 562.8 2750/24 .126 3.20 .195 4.95 4.460 113.28 16700 24852

DRAKA-USA

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-8B_176_2_00
131
Marine & Offshore
Product Specification J-121
IECIEEEUL
Conductor
Soft annealed tinned copper.
Stranding as shown in table below.
BOSTRIG MHV3-8B CABLE Conductor Shield
Three Conductor Power (Type N Jacket) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
8 kV - Shielded - 133% Level Insulation
Extruded thermosetting EPR, 90C-Type E.
Armored Only Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket
A jacket of flame retardant, heavy duty arctic Neoprene is applied
over the cable core. Thickness as shown in table below.

Armor
Braided Bronze.
Tests
Meets applicable test requirements in IEEE 45-1998 & 1993 (draft),
ICEA S-68-516, UL 1072, J-127 and flame test in IEC 60332-3, cat
TYPE N JACKET 8KV

A, A/F.

Rating
Application Listed by a Nationally Recognized Testing Lab (ETL) in confor-
mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
Bostrig MHV3-8B single conductor 8,000 volt shielded cables are suitable for use in
2001. Type approved by DNV, ABS and LRS.
commercial marine applications, MODUs, and platforms where flame retardant cables
having excellent physical and electrical properties are required. The cables have excellent
resistance to oils, abrasion, petrochemical fluids, moisture, and sunlight. Cables are also avail-
able with either a fully insulated grounding conductor or an un-insulated grounding conductor
evenly distributed in the interstices.

3/c 8 kV Shielded - 133% Level 177


BIW Insulation Jacket Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG/MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-8B-5 5 18.6 91/24 .140 3.56 .110 2.80 1.840 46.74 1930 2872
MHV3-8B-4 4 21.5 105/24 .140 3.56 .110 2.80 1.900 48.26 2060 3066
MHV3-8B-2 2 30.7 150/24 .140 3.56 .110 2.80 2.020 51.31 2380 3542
MHV3-8B-1 1 46.0 225/24 .140 3.56 .110 2.80 2.160 54.87 2850 4241
MHV3-8B-1/0 1/0 56.3 275/24 .140 3.56 .115 2.92 2.270 57.66 3200 4762
MHV3-8B-2/0 2/0 66.5 325/24 .140 3.56 .115 2.92 2.310 58.68 3500 5209
MHV3-8B-3/0 3/0 92.1 450/24 .140 3.56 .125 3.18 2.560 65.03 4350 6473
MHV3-8B-4/0 4/0 112.6 550/24 .140 3.56 .125 3.18 2.670 67.82 4900 7292
MHV3-8B-262 262 133.0 650/24 .140 3.56 .135 3.43 2.840 82.14 5550 8259
MHV3-8B-313 313 158.6 775/24 .140 3.56 .140 3.56 2.990 75.95 6300 9375
MHV3-8B-373 373 189.3 925/24 .140 3.56 .145 3.68 3.150 80.01 7100 10566
MHV3-8B-444 444 225.1 1100/24 .140 3.56 .150 3.81 3.310 84.07 8100 12054
MHV3-8B-535 535 271.2 1325/24 .140 3.56 .160 4.06 3.530 89.66 9350 13914
MHV3-8B-646 646 327.5 1600/24 .140 3.56 .165 4.19 3.750 95.25 10800 16072
MHV3-8B-777 777 393.8 1925/24 .140 3.56 .175 4.45 4.010 101.85 12600 18751
MHV3-8B-1111 1111 562.8 2750/24 .140 3.56 .195 4.95 4.520 114.81 16900 25150

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-8B_177_2_00
132
Marine & Offshore
Product Specification J-126
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-8BS CABLE Stranding as shown in table below.

Three Conductor Power (Type N Jacket & Sheath) Conductor Shield


Semi-conducting tape with extruded thermosetting semi-conducting
8 kV (IEC 3.6/6 kV) Shielded - 100% Level EPR.
Insulation
Armored and Sheathed Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.
Jacket and Sheath
Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
TYPE N JACKET 8KV

IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-126, and
flame test in IEC 60332-3, cat A, A/F.
Application Rating
Bostrig MHV-8BS three conductor 8,000 volt shielded cables are suitable for use in commer- Listed by a Nationally Recognized Testing Lab (ETL) in confor-
cial marine applications, MODUs, and platforms where flame retardant cables having excel- mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-2001.
lent physical and electrical properties are required. The cables have excellent resistance to oils, Type approved by DNV, ABS and LRS.
abrasion, petrochemical fluids, moisture, and sunlight. When required, these cables can be
supplied without the sheath over the armor. Cables are also available with either a fully insu-
lated grounding conductor or an un-insulated grounding conductor evenly distributed in the
interstices.

3/c - 8 kV (IEC 3.6/6 kV) Shielded - 100% Level 113


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-8BS-6 6 12.5 61/24 .118 3.00 .090/.110 2.29/2.80 1.840 46.74 1900 2828
MHV3-8BS-5 5 18.6 91/24 .118 3.00 .090/.110 2.29/2.80 1.920 48.77 2100 3125
MHV3-8BS-4 4 21.5 105/24 .118 3.00 .095/.110 2.40/2.80 1.990 50.55 2280 3393
MHV3-8BS-2 2 30.7 150/24 .118 3.00 .110/.110 2.80/2.80 2.140 54.36 2680 3988
MHV3-8BS-1 1 46.0 225/24 .118 3.00 .110/.110 2.80/2.80 2.280 57.91 3180 4732
MHV3-8BS-1/0 1/0 56.3 275/24 .118 3.00 .110/.110 2.80/2.80 2.400 60.96 3520 5238
MHV3-8BS-2/0 2/0 66.5 325/24 .118 3.00 .110/.110 2.80/2.80 2.430 61.72 3800 5655
MHV3-8BS-3/0 3/0 92.1 450/24 .118 3.00 .120/.110 3.05/2.80 2.670 67.82 4700 6994
MHV3-8BS-4/0 4/0 112.6 550/24 .118 3.00 .125/.140 3.18/3.56 2.850 72.39 5400 8036
MHV3-8BS-262 262 133.0 650/24 .118 3.00 .130/.140 3.30/3.56 2.970 75.44 6000 8929
MHV3-8BS-313 313 158.6 775/24 .118 3.00 .140/.140 3.56/3.56 3.170 80.52 6900 10268
MHV3-8BS-373 373 189.3 925/24 .118 3.00 .140/.140 3.56/3.56 3.320 84.33 7700 11459
MHV3-8BS-444 444 225.1 1100/24 .118 3.00 .145/.140 3.68/3.56 3.480 88.39 8700 12947
MHV3-8BS-535 535 271.2 1325/24 .118 3.00 .155/.140 3.94/3.56 3.700 93.98 10000 14881
MHV3-8BS-646 646 327.5 1600/24 .118 3.00 .165/.140 4.19/3.56 3.940 100.08 11500 17114
MHV3-8BS-777 777 393.8 1925/24 .118 3.00 .170/.140 4.32/3.56 4.140 105.16 13200 19644
MHV3-8BS-1111 1111 562.8 2750/24 .126 3.20 .195/.140 4.95/3.56 4.740 120.40 17900 26638

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-8_112_113_2_00
133
Marine & Offshore
Product Specification J-127
IECIEEEUL
Conductor
Soft annealed tinned copper.
BOSTRIG MHV3-8BS CABLE Stranding as shown in table below.

Conductor Shield
Three Conductor Power (Type N Jacket & Sheath) Semi-conducting tape with extruded thermosetting semi-conducting
EPR.
8 kV (IEC 6/10 kV) Shielded - 133% Level
Insulation
Armored and Sheathed Extruded thermosetting EPR, 90C-Type E.
Thickness as shown in table below.

Insulation Shield
Extruded thermosetting semi-conducting XLPO.

Metallic Braid Shield


Tinned copper braided shield, 85% minimum coverage.

Jacket and Sheath


Both the inner jacket applied over the cabled core and outer sheath
over the armor are flame retardant, heavy duty arctic Neoprene.
Thickness as shown in table below.

Armor
Braided Bronze.

Tests
Meets applicable test requirements in IEC 60502, IEC 60092-354,
TYPE N JACKET 8KV

IEEE 45-1998 & 1993 (draft), ICEA S-68-516, UL 1072, J-127, and
flame test in IEC 60332-3, cat A/F.
Application Rating
Bostrig MHV-8BS three conductor 8,000 volt shielded cables are suitable for use in commer- Listed by a Nationally Recognized Testing Lab (ETL) in confor-
cial marine applications, MODUs, and platforms where flame retardant cables having excel- mance to IEC 60502, UL 1072, ICEA S-68-516 and IEEE 1580-
lent physical and electrical properties are required. The cables have excellent resistance to oils, 2001. Type approved by DNV, ABS and LRS.
abrasion, petrochemical fluids, moisture, and sunlight. When required, these cables can be sup-
plied without the sheath over the armor. Cables are also available with either a fully insulated
grounding conductor or an un-insulated grounding conductor evenly distributed in the inter-
stices.

3/c - 8 kV (IEC 6/10 kV) Shielded - 133% Level 115


BIW Insulation Jacket/Sheath Nominal
Cable Type Conductor Size Wall Thickness Wall Thickness Cable Diameter Approx. Weight
AWG.MCM mm2 Stranding Inches mm Inches mm Inches mm Lbs/Mft kg/km
MHV3-8BS-5 5 18.6 91/24 .140 3.56 .110/.110 2.80/2.80 2.060 52.32 2350 3497
MHV3-8BS-4 4 21.5 105/24 .140 3.56 .110/.110 2.80/2.80 2.120 5.85 2510 3735
MHV3-8BS-2 2 30.7 150/24 .140 3.56 .110/.110 2.80/2. 80 2.240 56.90 2860 4256
MHV3-8BS-1 1 46.0 225/24 .140 3.56 .110/.110 2.80/2.80 2.380 60.45 3350 4985
MHV3-8BS-1/0 1/0 56.3 275/24 .140 3.56 .115/.110 2.92/2.80 2.500 63.50 3730 5550
MHV3-8BS-2/0 2/0 66.5 325/24 .140 3.56 .115/.110 2.92/2.80 2.540 64.52 4000 5953
MHV3-8BS-3/0 3/0 92.1 450/24 .140 3.56 .125/.140 3.18/3.56 2.840 72.14 5100 7590
MHV3-8BS-4/0 4/0 112.6 550/24 .140 3.56 .125/.140 3.18/3.56 2.950 74.93 5650 8408
MHV3-8BS-262 262 133.0 650/24 .140 3.56 .135/.140 3.43/3.56 3.100 78.99 6350 9450
MHV3-8BS-313 313 158.6 775/24 .140 3.56 .140/.140 3.56/3.56 3.270 83.06 7150 10640
MHV3-8BS-373 373 189.3 925/24 .140 3.56 .145/.140 3.68/3.56 3.440 87.38 8000 11905
MHV3-8BS-444 444 225.1 1100/24 .140 3.56 .150/.140 3.81/3.56 3.600 91.44 9000 13393
MHV3-8BS-535 535 271.2 1325/24 .140 3.56 .160/.140 4.06/3.56 3.810 96.77 10350 15402
MHV3-8BS-646 646 327.5 1600/24 .140 3.56 .165/.140 4.19/3.56 4.030 102.36 11800 17560
MHV3-8BS-777 777 393.8 1925/24 .140 3.56 .175/.140 4.45/356 4.280 108.71 13700 20388
MHV3-8BS-1111 1111 562.8 2750/24 .140 3.56 .195/.140 4.95/3.56 4.800 121.92 18200 27084

1610 Greens Road, Suite 200, Houston, TX 77032


Tel: 281.209.1070 Toll Free: 888.354.2225 ISO9001
24 hour: 281.851.1802 Fax: 281.209.3857 QSC3497
www.drakausa.com BG_MHV3-8_114_115_2_00
134
Bostrig Type P
0807
Page 53 of 62

S611T MARINE FIBER OPTIC CABLES


Tight buffer construction
2 to 48 fibers /
singlemode or multimode /
LSZH
1 2 3 4 5

Applications
The Drake S611T series of Marine and Offshore fiber optic cables is designed especially for the harsh environments of
commercial marine vessels, oil platforms and other similar applications.
Draka S611T low smoke/zero halogen, flame retardant cables offer the versatility and ease of use of our other offshore
cables in a construction suited for marine applications. They are compliant with the latest IEC requirements.
S611T cables meet the requirements of IEC 60793-1 and IEC 60793-2 specifications, are encapsulated in all dielectric,
tight buffered construction, individuall reinforced with aramid yarns and jacketed (breakout style). The breakout
components are cabled around a central member providing additonal tensile strength to the entire construction.
The thermoplastic low smoke/zero halogen jacketing system offers good resistance to chemicals, fluids, fungus, and
abrasion.
This product is readily available in an armored version.
Construction

1. Central Strength Member Dielectric material (epoxy fiberglass rod).


2. Fiber Multimode or singlemode fibers with an easily-strippable 900m tight buffering colored
per TIA/EIA 598.
3. Subunit Strength Member Aramid yarn
4. Subunit Jacket ChromaTek-L Halex low smoke zero halogen polyolefin.
5. Sheath ChromaTek-L Halex low smoke zero halogen polyolefin.

Features
Low smoke/zero halogen construction meets appropriate IEEE and IEC standards
for fire, smoke, and toxicity
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Gigabit Ethernet 802.3Z compliant

Ratings
Meets IEC 60794-1-1, 60794-1-2 and 60794-2.
Det Norske Veritas Type Approval Certificate E-7154.
American Bureau of Shipping Approval Certificate 04-HS440499B/2-PDA.
Lloyds Registry of Shipping Approval Certificate 00/00157E2.
Flame retardant per IEC 60332-3, CAT. A CAT A/F and IEEE 1202
Smoke density requirements of IEC 61034-1 and IEC 61034-2
Acid gas generation requirements of IEC 60754-1 and IEC 60754-2
Toxicity requirements of NES 713
Meets the performance requirements of IEEE 802.3z (Gigabit Ethernet)

www.DrakaMOG.com
Subject to change without prior notice DUSA_MOG53_0807
135
Bostrig Type P
0807
Page 54 of 62

S611T MARINE FIBER OPTIC CABLES

tight buffer construction


2 to 48 fibers / singlemode or multimode / LSZH

INSTALLATION OPERATING Approximate


DRAKA USA Number Pull Strength Bend Radius Tension Bend Radius Cable O.D. Cable Weight
Part Number of Fibers Newtons (lbs) cm (in) Newtons (lbs) cm (in) mm (in) Kg/km (Lbs/mft)
S611T-02R-xxy 2 600 (135) 12.8 (5.0) 200 (45) 6.4 (2.5) 6.4 (.252) 45 (30)

S611T-04-xxy 4 600 (135) 14.6 (5.8 200 (45) 7.3 (2.9) 7.3 (.287) 51 (35)

S611T-06-xxy 6 600 (135) 17.0 (6.8) 200 (45) 8.5 (3.4) 8.5 (.335) 71 (48)

S611T-08-xxy 8 600 (135) 19.4 (7.6) 200 (45) 9.7 (3.8) 9.7 (.381) 93 (63)

S611T-10-xxy 10 600 (135) 22.0 (8.4) 200 (45) 11.0 (4.3) 11.0 (.431) 119 (80)

S611T-12-xxy 12 600 (135) 24.4 (9.6) 200 (45) 12.2 (4.8) 12.2 (.481) 149 (100)

S611T-16-xxy 16 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 150 (101)

S611T-18-xxy 18 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 148 (100)

S611T-24-xxy 24 2700 (600) 29.6 (11.6) 600 (135) 14.8 (5.8) 14.8 (.581) 356 (238)

S611T-36-xxy 36 2700 (600) 34.0 (13.4) 600 (135) 17.0 (6.7) 17.0 (.670) 484 (325)

S611T-48-xxy 48 2700 (600) 46.0 (18.1) 600 (135) 23.1 (9.1) 23.0 (.905) 600 (403)

Replace the xxy with the Fiber Designation in the fiber performance table below.
NOTE: Fibers are not suitable for F07 crimp and cleave connector.
Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications.

FIBER PERFORMANCE
62.5m MULTIMODE 50 m MULTIMODE 200m MULTIMODE 8.3m SINGLEMODE
Fiber Designation 62X 50H 200S 010X
Applicable Specification IEC 60793-2 Type A1b ITU G.651 & IEC 60793-2 Type A1a ITU G.651 & IEC 60793-2 Type A1a ITU G.652 Table C & D Requirements
& IEC 60793-2 Type B1.1
Fiber Type Graded Index Graded Index Step Index Matched Clad
Core Diameter 62.5m 2.5m 50m 2.5m 200m 5m 8.3m Nominal
Cladding Diameter 125m 1m 125m 1m 230m 10m 125m 1m
Coating Diameter 242m 7m 242m 7m 500m 30m 242m 7m
Buffer Diameter 900m 50m 50m 2.5m 900m 50m 900m 50m
Numerical Aperture 0.275 0.015 0.200 0.015 .037 Nominal (2m 5% intensity) N/A
Mode Field Diameter N/A N/A N/A 9.1m 0.4m
Attenuation 3.5 dB/Km @ 850nm 3.5 dB/Km @ 850nm 12.0 dB/Km @ 820nm 0.70 dB/Km @ 1310nm
1.0 dB/Km @ 1300nm 1.0 dB/Km @ 1300nm 0.70 dB/Km @ 1550nm
Bandwidth 200 MHz/Km @ 850nm 500 MHz/Km @ 850nm 20 MHz/Km @ 820nm N/A
500 MHz/Km @ 1300nm 500 MHz/Km @ 1300nm N/A
Dispersion N/A N/A N/A 3.0 ps/nm-Km @1285-1330nm
N/A N/A N/A 18 ps/nm-Km @ 1550nm
Proof Test 100,000 psi 100,000 psi 100,000 psi 100,000 psi
CABLE PROPERTIES
Crush (IEC 60794-1-E3) 3000 N/ 10 cm
Impact (IEC 60794-1-E4) 20 impacts, 5J
Torsion (IEC 60794-1-E7) + 1 turn / 2 m, 100 cycles
Cable Bend (IEC 60794-1-E11) <0.1 dB/ + 6 turns

TEMPERATURE RANGE
Operation -20C to +80C
Installation -10C to +60C
Storage -40C to +80C

FIRE, SMOKE, AND TOXICITY CLASSIFICATIONS


Flame retardant IEC 60332-3, CAT.A CAT A/F and IEEE 1202
Smoke density IEC 61034-1 and IEC 61034-2
Acid gas penetration IEC 60754-1 and IEC 60754-2
Toxicity NES 713
www.DrakaMOG.com
Subject to change without prior notice DUSA_MOG54_0807
136
Bostrig Type P
0807
Page 55 of 62

S670T ARMORED AND SHEATHED MARINE FIBER OPTIC CABLES


Tight buffer construction
2 to 48 fibers /
singlemode or multimode /
LSZH / Armored & Sheathed
1 2 3 4 5 6 7

Applications
The Drake S670T series of Marine and Offshore fiber optic cables is designed especially for the harsh environments of
commercial marine vessels, oil platforms and other similar applications.
Draka S670T low smoke/zero halogen, flame retardant cables offer the versatility and ease of use of our other offshore
cables in a construction suited for marine applications. They are compliant with the latest IEC requirements.
S670T cables meet the requirements of IEC 60793-1 and IEC 60793-2 specifications, are encapsulated in all dielectric,
tight buffered construction, individuall reinforced with aramid yarns and jacketed (breakout style). The breakout
components are cabled around a central member providing additonal tensile strength to the entire construction.
The thermoplastic low smoke/zero halogen jacketing system offers good resistance to chemicals, fluids, fungus, and
abrasion.
This product is readily available in a non-armored version.
Construction

1. Central Strength Member Dielectric material (epoxy fiberglass rod).


2. Fiber Multimode or singlemode fibers with an easily-strippable 900m tight buffering colored
per TIA/EIA 598.
3. Subunit Strength Member Aramid yarn
4. Subunit Jacket ChromaTek-L Halex low smoke zero halogen polyolefin.
5. Jacket ChromaTek-L Halex low smoke zero halogen polyolefin.
6. Armor Braided bronze in accordance with IEEE 1580 (2001).
7. Sheath ChromaTek-L Halex low smoke zero halogen polyolefin.

Features
Low smoke/zero halogen construction meets appropriate IEEE and IEC standards
for fire, smoke, and toxicity
Superior resistance to oil, abrasion, moisture, sunlight, mud, crush and impact
Gigabit Ethernet 802.3Z compliant

Ratings
Meets IEC 60794-1-1, 60794-1-2 and 60794-2.
Det Norske Veritas Type Approval Certificate E-7155.
American Bureau of Shipping Approval Certificate 04-HS440499B/2-PDA.
Lloyds Registry of Shipping Approval Certificate 00/00157E2.
Flame retardant per IEC 60332-3, CAT. A CAT A/F and IEEE 1202
Smoke density requirements of IEC 61034-1 and IEC 61034-2
Acid gas generation requirements of IEC 60754-1 and IEC 60754-2
Toxicity requirements of NES 713
Meets the performance requirements of IEEE 802.3z (Gigabit Ethernet)

www.DrakaMOG.com
Subject to change without prior notice DUSA_MOG55_0807
137
Bostrig Type P
0807
Page 54
56 of 62

S670T ARMORED
S611TAND
MARINE
SHEATHED
FIBER
MARINE
OPTICFIBER
CABLES
OPTIC CABLES

tight buffer construction


2 to 48 fibers/ /singlemode
4 fibers singlemodeorormultimode
multimode/ /LSZH
LSZH

INSTALLATION OPERATING Approximate


DRAKA USA Number Pull Strength Bend Radius Tension Bend Radius Cable O.D. Cable Weight
Part Number of Fibers Newtons (lbs) cm (in) Newtons (lbs) cm (in) mm (in) Kg/km (Lbs/mft)
S607T-02R-xxy
S611T-02R-xxy 2 600 (135) 12.8 (5.0) 200 (45) 6.4 (2.5) 6.4 (.252) 45 (30)

S607T-04-xxy
S611T-04-xxy 4 600 (135) 14.6 (5.8 200 (45) 7.3 (2.9) 7.3 (.287) 51 (35)

S607T-06-xxy
S611T-06-xxy 6 600 (135) 17.0 (6.8) 200 (45) 8.5 (3.4) 8.5 (.335) 71 (48)

S607T-08-xxy
S611T-08-xxy 8 600 (135) 19.4 (7.6) 200 (45) 9.7 (3.8) 9.7 (.381) 93 (63)

S607T-10-xxy
S611T-10-xxy 10 600 (135) 22.0 (8.4) 200 (45) 11.0 (4.3) 11.0 (.431) 119 (80)

S607T-12-xxy
S611T-12-xxy 12 600 (135) 24.4 (9.6) 200 (45) 12.2 (4.8) 12.2 (.481) 149 (100)

S607T-16-xxy
S611T-16-xxy 16 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 150 (101)

S607T-18-xxy
S611T-18-xxy 18 2700 (600) 25.7 (10.2) 600 (135) 12.8 (5.1) 12.8 (.507) 148 (100)

S607T-24-xxy
S611T-24-xxy 24 2700 (600) 29.6 (11.6) 600 (135) 14.8 (5.8) 14.8 (.581) 356 (238)

S607T-36-xxy
S611T-36-xxy 36 2700 (600) 34.0 (13.4) 600 (135) 17.0 (6.7) 17.0 (.670) 484 (325)

S607T-48-xxy
S611T-48-xxy 48 2700 (600) 46.0 (18.1) 600 (135) 23.1 (9.1) 23.0 (.905) 600 (403)

Replace the xxy with the Fiber Designation in the fiber performance table below.
NOTE: Fibers are not suitable for F07 crimp and cleave connector.
Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications.

FIBER PERFORMANCE
62.5m MULTIMODE 50 m MULTIMODE 200m MULTIMODE 8.3m SINGLEMODE
Fiber Designation 62X 50H 200S 010X
Applicable Specification IEC 60793-2 Type A1b ITU G.651 & IEC 60793-2 Type A1a ITU G.651 & IEC 60793-2 Type A1a ITU G.652 Table C & D Requirements
& IEC 60793-2 Type B1.1
Fiber Type Graded Index Graded Index Step Index Matched Clad
Core Diameter 62.5m 2.5m 50m 2.5m 200m 5m 8.3m Nominal
Cladding Diameter 125m 1m 125m 1m 230m 10m 125m 1m
Coating Diameter 242m 7m 242m 7m 500m 30m 242m 7m
Buffer Diameter 900m 50m 50m 2.5m 900m 50m 900m 50m
Numerical Aperture 0.275 0.015 0.200 0.015 .037 Nominal (2m 5% intensity) N/A
Mode Field Diameter N/A N/A N/A 9.1m 0.4m
Attenuation 3.5 dB/Km @ 850nm 3.5 dB/Km @ 850nm 12.0 dB/Km @ 820nm 0.70 dB/Km @ 1310nm
1.0 dB/Km @ 1300nm 1.0 dB/Km @ 1300nm 0.70 dB/Km @ 1550nm
Bandwidth 200 MHz/Km @ 850nm 500 MHz/Km @ 850nm 20 MHz/Km @ 820nm N/A
500 MHz/Km @ 1300nm 500 MHz/Km @ 1300nm N/A
Dispersion N/A N/A N/A 3.0 ps/nm-Km @1285-1330nm
N/A N/A N/A 18 ps/nm-Km @ 1550nm
Proof Test 100,000 psi 100,000 psi 100,000 psi 100,000 psi
CABLE PROPERTIES
Crush (IEC 60794-1-E3) 3000 N/ 10 cm
Impact (IEC 60794-1-E4) 20 impacts, 5J
Torsion (IEC 60794-1-E7) + 1 turn / 2 m, 100 cycles
Cable Bend (IEC 60794-1-E11) <0.1 dB/ + 6 turns

TEMPERATURE RANGE
Operation -20C to +80C
Installation -10C to +60C
Storage -40C to +80C

FIRE, SMOKE, AND TOXICITY CLASSIFICATIONS


Flame retardant IEC 60332-3, CAT.A CAT A/F and IEEE 1202
Smoke density IEC 61034-1 and IEC 61034-2
Acid gas penetration IEC 60754-1 and IEC 60754-2
Toxicity NES 713
www.DrakaMOG.com
Subject to change without prior notice DUSA_MOG56_0807
DUSA_MOG54_0807
138
50 Coaxial cable 2.7/7.3AF Low Loss FRNC-C
Coaxials basing upon DIN 47264, EN 50117-1 and IEC 61196-1
Standards applied

DIN 47264; EN 50117-1; IEC 61196-1

Fire Rating Standards

Halogen Free IEC 60754-2


Low smoke IEC 61034-1,2
Flame propogation IEC 60332-1
Fire retardant IEC 60332-3-24 (cat. C)

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction

Inner conductor Bare copper wire, 2.71 + 0.02 mm


Insulation Foam skinned polyethylene (Foam-PE), 7.25 + 0.10 mm
Outer conductor Aluminium PET Aluminium foil
and copper braid, tinned (ca. 93% optical coverage)
Sheath FRNC, black RAL 9005, 10.3 + 0.2 mm

Technical Data
Prod.number Outer Weight of Copper
Designation Type Tensile force
Draka Comteq diameter cable approx. content
(inner/outer) (mm) (kg/km) (kg/km) (N)

CK7550700 Low Loss FRNC-C 2.7/7.3 AF 10.3 145.0 90.0 505

139
Mechanical Properties
Minimal bending radius 50 mm without load (5 x outer diameter)
100 mm with load (10 x outer diameter)
Temperature range, during operation -30C upto + 70C
during installation -15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance Inner conductor 3.1 /km
. Outer conductor 4.7 /km
Mutual capacitance nom. 79 pF/km
Characteristic impedance (50 2)
Nominal velocity of propagation approx. 84 %
Transfer Impedance 1 MHz < 5 m/m
. 10 MHz < 4 m/m
. 100 MHz < 2 m/m
Operating voltage 1.200 Vrms
Test voltage Inner/outer conductor 5.000 Vrms
Screening factor 100-1000 MHz > 90 dB
1000-3000 MHz > 80 dB
Insulation resistance > 10 G.km

Electrical data (at 20 C)


f Attenuation Max. power rating Return Loss
(MHz) (dB/100m) (W) (dB)
(ambient temperature 40
C and max. inner
(several peaks are allowed)
conductor temperature
100 C
nominal maximal Frequency (dB)
1 0.4 17.328 10-450 MHz > 26
10 1.3 5.480 450-1000 MHz > 23
100 4.1 1.710 1 3 GHz > 18
200 5.7 1.132
500 9.3 716
800 12.2 585
1000 13.6 523
1500 16.7 427
2000 19.5 351
2500 22.1 325
3000 24.8 261
3500 27.1 240
4000 29.3 246
5250 34.3 216
5725 36.3 205
6000 37.2 200

www.DrakaMOG.com
140
50 Coaxial cable - RG 213 FRNC-B
RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied

acc. to MIL-C-17F and MIL-C-17G

Fire Rating Standards

Halogen Free IEC 60754-2


Low smoke IEC 61034-1,2
Flame propogation IEC 60332-1
Fire retardant IEC 60332-3-23 (cat. B)

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction

Inner conductor Stranded copper wires 7 x 0.75, 2.25 + 0.01 mm


Insulation Polyethylene (PE), 7.25 + 0.05 mm
Braid Bare copper braid (ca. 96% optical coverage)
Sheath FRNC, black 10.3 + 0.15 mm

Technical Data
Prod.number Outer Weight of Copper
Designation Type Tensile force
Draka Comteq diameter cable approx. content
(inner/outer) (mm) (kg/km) (kg/km) (N)

CK2775400 M17/074 RG 214 2.25L/7.25 10.3 157 86.7 470

141
Mechanical Properties
Minimal bending radius 50 mm without load (5 x outer diameter)
100 mm with load (10 x outer diameter)
Temperature range, during operation -40C upto + 85C
during installation -15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance Inner conductor 5.7 /km
Outer conductor 3.9 /km
Mutual capacitance nom. 100 pF/km
Characteristic impedance (50 2)
Nominal velocity of propagation approx. 66 %
Propagation delay 427 ns/100m
Delay skew 12 ns/100m
Operating voltage 3.700 Vrms
Test voltage Inner/outer conductor 10.000 Vrms

Electrical data (at 20 C)


f Attenuation Max. power rating Return Loss
(MHz) (dB/100m) (W) (dB)
(ambient temperature 25
C and max. inner (several peaks are
conductor temperature 70 allowed)
C
1 28.0
10 1.8 2.300
100 6.8 920
200 9.0 570
400 14.4 380
1.000 24.7 210 23.5
1.500 31.5 170
2.000 36.4 140
3.000 46.6 100
5.200 62.0 73
5.800 67.0 67

www.DrakaMOG.com

142 Datacomm03_Jan_07
50 Coaxial cable - RG 214 FRNC-B
RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied

Acc. To MIL-C-17F and MIL-C-17G

Fire Rating Standards

Halogen Free IEC 60754-2


Low smoke IEC 61034-1,2
Flame propogation IEC 60332-1
Fire retardant IEC 60332-3-23 (cat. B)

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction

Inner conductor Stranded copper wires, silver plated 7 x 0.75, 2.25 + 0.01 mm
Insulation Polyethylene (PE), 7.25 + 0.05 mm
st
1 braid Bare copper braid, silver plated (ca. 94% optical coverage)
2nd braid Bare copper braid, silver plated (ca. 97% optical coverage)
Sheath FRNC, black 10.8 + 0.15 mm

Technical Data
Prod.number Outer Weight of Copper
Designation Type Tensile force
Draka Comteq diameter cable approx. content
(inner/outer) (mm) (kg/km) (kg/km) (N)

CK2950901 M17/075 RG 214 FRNC-B 2.25Ls/7.25Ds 10.8 200 132.9 730

143
Mechanical Properties
Minimal bending radius 50 mm without load (5 x outer diameter)
100 mm with load (10 x outer diameter)
Temperature range, during operation -40C upto + 85C
during installation -15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance Inner conductor 5.7 /km
. 1st braid 6.2 /km
. 2nd braid 6.2 /km
Mutual capacitance nom. 100 pF/km
Characteristic impedance (50 2)
Nominal velocity of propagation approx. 66 %
Maximum operating frequency 11 GHz
Operating voltage 3.700 Vrms
Test voltage Inner/outer conductor 10.000 Vrms

Electrical data (at 20 C)


f Attenuation Max. power rating Return Loss
(MHz) (dB/100m) (W) (dB)
(ambient temperature 25
C and max. inner (several peaks are
conductor temperature 70 allowed)
C
50 4.9 1.500 -
100 6.9 920 > 23
400 15.1 330 -
1.000 26.5 160 > 20
3.000 50.6 75 > 19
5.000 - - > 18
5.200 67.8 61 -
5.800 73.0 56 -
11.000 - - > 17

www.DrakaMOG.com

144 Datacomm04_Jan_07
50 Coaxial cable - RG 214 PVC
RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied

Acc. To MIL-C-17F and MIL-C-17G

Fire Rating Standards

Flame propogation IEC 60332-1

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction

Inner conductor Stranded copper wires, silver plated 7 x 0.75, 2.25 + 0.01 mm
Insulation Polyethylene (PE), 7.25 + 0.05 mm
1st braid Bare copper braid, silver plated (ca. 94% optical coverage)
2nd braid Bare copper braid, silver plated (ca. 97% optical coverage)
Sheath PVC, black 10.8 + 0.15 mm

Technical Data
Prod.number Outer Weight of Copper
Designation Type Tensile force
Draka Comteq diameter cable approx. content
(inner/outer) (mm) (kg/km) (kg/km) (N)

CK2775700 M17/075 RG 214 2.25Ls/7.25Ds 10.8 200 132.9 730

145
Mechanical Properties
Minimal bending radius 50 mm without load (5 x outer diameter)
100 mm with load (10 x outer diameter)
Temperature range, during operation -40C upto + 85C
during installation -15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance Inner conductor 5.7 /km
. 1st braid 6.2 /km
. 2nd braid 6.2 /km
Mutual capacitance nom. 100 pF/km
Characteristic impedance (50 2)
Nominal velocity of propagation approx. 66 %
Maximum operating frequency 11 GHz
Operating voltage 3.700 Vrms
Test voltage Inner/outer conductor 10.000 Vrms

Electrical data (at 20 C)


f Attenuation Max. power rating Return Loss
(MHz) (dB/100m) (W) (dB)
(ambient temperature 25
C and max. inner (several peaks are
conductor temperature 70 allowed)
C
50 4.9 1.500 -
100 6.9 920 > 23
400 15.1 330 -
1.000 26.5 160 > 20
3.000 50.6 75 > 19
5.000 - - > 18
5.200 67.8 61 -
5.800 73.0 56 -
11.000 - - > 17

www.DrakaMOG.com

146 Datacomm05_Jan_07
50 Coaxial cable - RG 223 FRNC-B
RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied

Acc. To MIL-C-17F and MIL-C-17G

Fire Rating Standards

Halogen Free IEC 60754-2


Low smoke IEC 61034-1,2
Flame propogation IEC 60332-1
Fire retardant IEC 60332-3-24 (cat. C)

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction

Inner conductor Stranded copper wires, silver plated 0.9 + 0.01 mm


Insulation Polyethylene (PE), 2.95 + 0.05 mm
st
1 braid Bare copper braid, silver plated (ca. 96% optical coverage)
2nd braid Bare copper braid, silver plated (ca. 96% optical coverage)
Sheath FRNC, black 5.4 + 0.10 mm

Technical Data
Prod.number Outer Weight of Copper
Designation Type Tensile force
Draka Comteq diameter cable approx. content
(inner/outer) (mm) (kg/km) (kg/km) (N)

CK7676500 M17/84 RG 223 FRNC-B 0.89s/2.95Ds 5.4 54.7 40.5 240

147
Mechanical Properties
Minimal bending radius 25 mm without load (5 x outer diameter)
50 mm with load (10 x outer diameter)
Temperature range, during operation -40C upto + 85C
during installation -15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance Inner conductor 29.1 /km
. 1st braid 13.5 /km
. 2nd braid 13.5 /km
Mutual capacitance nom. 100 pF/km
Characteristic impedance (50 2)
Nominal velocity of propagation approx. 66 %
Maximum operating frequency 12.4 GHz
Operating voltage 1.400 Vrms
Test voltage Inner/outer conductor 5.000 Vrms

Electrical data (at 20 C)


f Attenuation Max. power rating Return Loss
(MHz) (dB/100m) (W) (dB)
(ambient temperature 25
C and max. inner (several peaks are
conductor temperature 70 allowed)
C
Frequency (dB)
50 9.8 350 100 MHz > 27.0
400 28.4 86 1 GHz > 23.5
1.000 45.9 50 2 GHz > 21.5
3.000 83.1 32 4-5 GHz > 21.0
5.200 112.7 24 10 GHz > 20.0
5.800 120.6 22

www.DrakaMOG.com

148 Datacomm06_Jan_07
50 Coaxial cable - RG 223 PVC
RG-Cables acc. To MIL-C-17F and MIL-C-17G
Standards applied

Acc. To MIL-C-17F and MIL-C-17G

Fire Rating Standards

Flame propogation IEC 60332-1

Application
RG - types acc. to US Military Specification MIL-C-17F. RG - cables are used in the whole field of
commercial electronics and radio frequency engineering wherever high quality is required, e.g.:
long service life and good ageing stability
high abrasion resistance of sheath and resistance to permanent action of chemicals
high flexibility and low attenuation
minimum characteristic impedance deviations and good homogeneity
use of standardized connectors

Construction

Inner conductor Stranded copper wires, silver plated 0.9 + 0.01 mm


Insulation Polyethylene (PE), 2.95 + 0.05 mm
1st braid Bare copper braid, silver plated (ca. 96% optical coverage)
2nd braid Bare copper braid, silver plated (ca. 96% optical coverage)
Sheath PVC, black 5.4 + 0.10 mm

Technical Data
Prod.number Outer Weight of Copper
Designation Type Tensile force
Draka Comteq diameter cable approx. content
(inner/outer) (mm) (kg/km) (kg/km) (N)

CK2776500 M17/84 RG 223 0.89s/2.95Ds 5.4 54.7 40.5 240

149
Mechanical Properties
Minimal bending radius 25 mm without load (5 x outer diameter)
50 mm with load (10 x outer diameter)
Temperature range, during operation -40C upto + 85C
during installation -15C upto + 55C

Electrical Properties (at 20C 5C)


DC resistance Inner conductor 29.1 /km
. 1st braid 13.5 /km
. 2nd braid 13.5 /km
Mutual capacitance nom. 100 pF/km
Characteristic impedance (50 2)
Nominal velocity of propagation approx. 66 %
Maximum operating frequency 12.4 GHz
Operating voltage 1.400 Vrms
Test voltage Inner/outer conductor 5.000 Vrms

Electrical data (at 20 C)


f Attenuation Max. power rating Return Loss
(MHz) (dB/100m) (W) (dB)
(ambient temperature 25
C and max. inner (several peaks are
conductor temperature 70 allowed)
C
Frequency (dB)
50 9.8 350 100 MHz > 27.0
400 28.4 86 1 GHz > 23.5
1.000 45.9 50 2 GHz > 21.5
3.000 83.1 32 4-5 GHz > 21.0
5.200 112.7 24 10 GHz > 20.0
5.800 120.6 22

www.DrakaMOG.com

150 Datacomm07_Jan_07
6 FOILS 4x2x0.57 (AWG 23) MULTIMEDIA LSHF-FR
Shielded 100 Data cable ISO/IEC 11801 CAT-7
Standards applied

International ISO/IEC 11801 2nd ed.


USA ANSI/EIA/TIA 568A
Europe NEN-EN 50173

Cat 7 NEN 11156-5 (IEC 61156)


Construction NEN-EN 50288-2-1

Application Fire Rating Standards


Primary (Campus), Secondary (Riser), Tertiary Halogen Free IEC 60754-2
(Horizontal) IEEE 802.3: 10Base-T; 100Base-T; Low smoke IEC 61034-1,2
1000Base-T; 10Gbase-T; IEEE 802.5 16MB; ISDN; Flame propogation IEC 60332-1
TPDDI; ATM Fire retardant IEC 60332-3-24 (cat. C)

Construction

Conductor Bare copper wire 0.57 mm (AWG23)


Insulation Polyethylene, 1.4 mm
Pair screen Al-laminated plastic foil,
Patented wrapping of two pairs each
Twisting 2 cores to the pair
Cable lay up 4 pair to the core
Overall sheath Copper braid, tinned (ca. 65% coverage)
Sheath LSHF, mellon orange RAL 1028
Sheath marking DRAKA COMTEQ 6FOIL S/FTP 4x2x0.57 MULTIMEDIA

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1 white/blue and blue,
Pair 2 white/orange and orange,
Pair 3 white/green and green,
Pair 4 white/brown and brown

Technical Data
No. of cores Weight of
Prod.number Outer Fire Load Copper Tensile
Designation and cable
Draka Comteq diameter content force
cond.area approx.
(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N)

CD7679731 S/FTP AWG23 LSHF-FR 2x2x0.57 7.9 642 0.178 81 39 340

151
Mechanical Properties
Bending radius 35 mm without load
70 mm with load
Temperature range, during operation -20C upto + 60C
during installation 0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance 135 /km
Resistance unbalance 2%
Insulation resistance (500 V) 2000 M *km
Capacitance at 800 Hz nom. 43 nF/km
Capacitance unbalance (pair to ground) 1500 pF/km
Characteristic impedance (1-100 MHz) (100 15)
(100-250 MHz) (100 18)
(250-600 MHz) (100 25)
(600-1200 MHz) (100 30)
Nominal velocity of propagation approx. 79 %
Propagation delay 427 ns/100m
Delay skew 12 ns/100m
Test voltage (DC, 1 min) 1000 V
Core/Core and Core/Screen
Transfer impedance at 1 MHz 5 m /m
at 10 MHz 5 m /m
at 30 MHz 15 m /m
at 100 MHz 30 m /m

Nominal transmission characteristics acc. to Category 7 (at 20 C)


f Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss
(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)
1.0 2.0 117 114 115 112 105 103 20
4.0 3.6 117 114 113 110 93 91 23
10.0 5.7 117 114 112 109 85 83 25
16.0 7.2 114 111 107 104 81 79 25
20.0 8.1 113 110 105 102 79 77 25
31.2 10.1 110 107 100 97 75 73 24
62.5 14.5 105 102 91 88 69 67 22
100.0 18.5 102 99 84 81 65 63 20
125.0 21.1 101 98 80 77 63 61 19
155.5 23.4 100 97 76 73 61 59 19
175.0 25.1 99 96 74 71 60 58 18
200.0 26.8 98 95 71 68 59 57 18
250.0 30.1 96 93 66 63 57 55 17
300.0 33.0 95 92 62 59 55 53 17
450.0 42.6 93 90 50 47 52 50 17
600.0 49.0 91 88 42 39 49 47 17
750.0 63.3 87 84 24 21 45 43 -
900.0 69.3 86 83 17 14 43 41 -
1000.0 77.5 85 82 7.3 4.3 41 39 -

152
www.DrakaMOG.com
75 CATV cable 1.0/4.8 AF FRNC-C
CATV Drop Cable

Standards applied

Screening efficiency EN 50117-1

Application Fire Rating Standards

Drop cables are used in TV signal distribution Halogen Free IEC 60754-2
networks and as antenna cable for terrestric and Low smoke IEC 61034-1,2
satellite broadcast systems. Flame propogation IEC 60332-1
Fire retardant IEC 60332-3-24 (cat. C)

Construction

Inner conductor Bare copper wire, 1.0 mm


Insulation Foam skinned polyethylene (Foam-PE), 4.65 + 0.10 mm
Outer conductor Aluminium PET Aluminium foil
under copper braid, tinned (ca. 40% optical coverage)
Sheath FRNC-C, white 6.8 + 0.2 mm

Technical Data
Prod.number Outer Weight of Copper
Designation Type Tensile force
Draka Comteq diameter cable approx. content
(inner/outer) (mm) (kg/km) (kg/km) (N)

CT2850402 1.0/4.8AF FRNC-C 1.0/4.8 AF 6.8 45.0 14.5 110

153
Electrical Properties (at 20C 5C)
DC resistance Inner conductor 22 /km
. Outer conductor 25 /km
Mutual capacitance nom. 55 pF/km
Characteristic impedance (75 2)
Nominal velocity of propagation approx. 85 %
Screening factor 30-1000 MHz > 80 dB

Electrical data (at 20 C)


f Attenuation Return Loss
(MHz) (dB/100m) (dB)
(several peaks are allowed)
nominal Frequency (dB)
5 1.6 5 30 MHz > 26
50 4.6 30 470 MHz > 23
100 6.4 480 862 MHz > 20
200 8.9 862 2150 MHz > 18
400 12.7
862 18.9
950 19.8
1000 20.5
1350 23.8
1600 26.4
1750 27.6
2150 30.8
2550 33.6
3000 36.5

www.DrakaMOG.com

154 Datacomm08_Jan_07
75 CATV cable 1.6/7.3 AF FRNC
CATV Distribution and Drop Cable
Standards applied

Screening efficiency acc. to EN 50117-1 and


draft EN 50117-2-2, 4 a 5
May 2002.
EN 50083-2/A1 screening
class A

Application Fire Rating Standards

Drop cables are used in TV signal distribution Halogen Free IEC 60754-2
networks and as antenna cable for terrestric and Low smoke IEC 61034-1,2
satellite broadcast systems. Flame propogation IEC 60332-1
Fire retardant IEC 60332-3-24 (cat. C)

Construction

Inner conductor Bare copper wire, 1.6 mm


Insulation Foam skinned polyethylene (Foam-PE), 7.2 mm
Outer conductor Aluminium PET Aluminium foil
under copper braid, tinned (ca. 60% optical coverage)
Sheath FRNC-C, black 10.0 + 0.3 mm

Technical Data
Prod.number Outer Weight of Copper Bending
Designation Type Tensile force
Draka Comteq diameter cable approx. content radius
(inner/outer) (mm) (kg/km) (kg/km) (mm) (N)

CT2760901 1.6/7.3AF FRNC-C 1.6/7.3 AF 10.0 85.0 35.3 50.0 300

155
Electrical Properties (at 20C 5C)
DC resistance Inner conductor 9 /km
. Outer conductor 14 /km
Mutual capacitance nom. 55 pF/km
Characteristic impedance (75 2)
Nominal velocity of propagation approx. 80 %
Screening factor 30-1000 MHz > 80 dB

Electrical data (at 20 C)


f Attenuation Return Loss
(MHz) (dB/100m) (dB)
(several peaks are allowed)
nominal Frequency (dB)
5 1.0 5 30 MHz > 26
50 3.0 30 470 MHz > 23
100 4.2 480 862 MHz > 20
200 6.0 862 2150 MHz > 18
400 8.8
862 12.9
1000 14.6
1350 17.5
1600 19.3
1750 20.2
2150 23.1
2550 25.2
3000 27.8

www.DrakaMOG.com

156 Datacomm09_Jan_07
75 CATV cable Coax10 AD 10S FRNC-C
CATV Drop Cable
Standards applied

Screening Screening Class A


efficiency acc. to EN 50117-2-1, EN
50117-2-2, EN 50117-2-4 and
EN 50117-2-5 further EN
500083-2A1, EN 50117-1.

Application Fire Rating Standards


Drop cables are used in private and commercial TV Halogen Free IEC 60754-2
signal distribution networks and as antenna cable Low smoke IEC 61034-1,2
for terrestrial and satellite broadcast systems. This Flame propogation IEC 60332-1
predestined head-end cable is manufactured with Fire retardant IEC 60332-3-24 (cat. C)
vacuum technology. The cable layers thereby have
high friction forces which allow automatic
dismantling also at small lengths.

Construction

Inner conductor Bare copper wire, 1.0 mm


Insulation Gas injected foam polyethylene (Foam-PE), 4.55 mm
Outer conductor Aluminium PET foil, longitudinal, bonded to the insulation,
under copper braid, tinned (ca. 70% optical coverage) and Aluminium PET
foil longitudinal, bonded to the sheath, 4.55 mm
Sheath FRNC-C, black 6.8 + 0.2 mm
Marking DRAKA COMTEQ OAX10 AD S + meter marking + batch number

Technical Data
Prod.number Outer Weight of Copper Bending
Designation Tensile force
Draka Comteq diameter cable approx. content radius
(mm) (kg/km) (kg/km) (mm) (N)

CK2689305 Coax10 AD 10 S FRNC-C 6.8 47.0 21.9 35.0 175

157
Mechanical Properties
Minimal bending radius Without load 30 mm (5 x outer diameter)
. With load 65 mm (10 x outer diameter)
Temperature range during operation -40C upto + 85C
. during installation -15C upto + 55C
Corrosiveness FRNC-C acc. to IEC 60754-2
Friction forces between cable layers
Dielectric foil braid foil - sheath. > 80 N
(Pull test with 300 mm overlapping zone)
Inner conductor dielectric > 15 N
(acc. to DIN EN 50 289-3-17) (Pull test with 50 mm overlapping zone)

Electrical Properties (at 20C 5C)


DC resistance Inner conductor 22 /km
. Outer conductor 14 /km
Mutual capacitance nom. 52 pF/km
Characteristic impedance (75 2)
Nominal velocity of propagation approx. 85 %
Screening factor 30-1000 MHz > 110 dB
1 - 2 GHz > 100 dB
2 - 3 GHz > 100 dB
Transfer impedance 5 - 30 MHz > 5 m.m
Electrical strength Dilectric 2 kVDC 1 min
Sheath 3.75 kVDC 1 min

Electrical data (at 20 C)


f Attenuation Return Loss
(MHz) (dB/100m) (dB)
(several peaks are allowed)
nominal Frequency (dB)
5 1.6 5 30 MHz > 26
50 4.3 30 470 MHz > 24
100 6.2 470 1000 MHz > 20
200 8.7 1000 3000 MHz > 18
400 12.5
862 18.6
950 19.8
1350 23.7
1750 27.2
2150 30.5
3000 36.9

www.DrakaMOG.com

158 Datacomm10_Jan_07
Analogue Audio Cable 110 AC10 SS 26/7 10P
Analogue Audio Cable based upon ARD-specification and acc. to AES/EBU-
recommendation

Fire Rating Standards

Halogen Free IEC 60754-2


Low smoke IEC 61034-1,2
Flame propogation IEC 60332-1
Fire retardant IEC 60332-3-24 (cat. C)

Application
Audio cables are used in professional broadcasting systems for the transmission of analogue and
digital signals.

Construction

Inner conductor Stranded bare copper wires, 0.48 mm (0.14 mm / AWG 26/7)
Insulation Foam skinned polyethylene (Foam-PE), 1.2 mm
Pair stranding Two cores twisted to the pair
Pair identification a core: white, b core: blue
(the above colours in regular intervals)
Pair screen Aluminium PET foil, aluminium inside and stranded copper drain wires,
tinned.
Pair insulation of PET foil.
the one-pair cable
Pair insulation of FRNC, flame retardant copolymer
the multi-pair cable
Colour and Grey RAL 7001 with number printing
identification
Cable lay-up n-pairs twisted in layers
Overall screen Aluminium-PET foil under copper braid, tinned.
Sheath FRNC-C, grey RAL 7001 13.7 mm
Marking DRAKA MULTIMEDIA CABLE GERMANY AC 10 SS 26/7 10P AES/EBU

Technical Data
Prod.number Outer Weight of Copper
Designation Type Tensile force
Draka Comteq diameter cable approx. content
(nxnxmm) (mm) (kg/km) (kg/km) (N)

CT7651811 AC10 SS 26/7 10P PiMF 10x2x20.48 13.7 195.0 110.9 550

159
Mechanical Properties
Minimal bending radius Without load 130 mm (10 x outer diameter)
. With load 200 mm (15 x outer diameter)
Temperature range -30C upto + 70C
Corrosiveness FRNC-C acc. to IEC 60754-2

Electrical Properties (at 20C 5C)


DC loop resistance < 288 /km
Insulation resistance 2000 M.km
Mutual capacitance at 800 Hz Nom. 45 nF/km
Capacitance unbalance (pair to ground) < 1200 pF/km
Nominal velocity of propagation approx. 78 %
Test voltage (50 Hz, 1min) 700 VRMS
Core/core and core/screen)
Characteristic impedance (6 MHz) 110 10%
Transfer impedance up to 10 MHz > 10 m.m
up to 100 MHz > 100 m.m

Electrical data (at 20 C)


f NEXT Attenuation
(MHz) (dB/300m) (dB/100m)

0.015 85 0.55
1.0 85 3.0
4.0 90 5.3
10.0 90 8.1
20.0 85 11.5

www.DrakaMOG.com

160 Datacomm11_Jan_07
D92aici.e20
12.09.2007 14:51
Page 1 of 2

Flame retardant AICI-I/O/RM-W


Armoured industrial cable
AICI-I/O/RM-W
Indoor and outdoor
Flame retardant and halogen free
Steel wire braiding
Tight buffer

Optical cable for industrial environments. The cable is suitable


for both indoor and outdoor installation. Continiuous
submergence in water is not recommended. Outer sheath is
made from black UV-stabilized and weather resistant material
and may be exposed for shorter periods to fluids such as
diesel and mineral oils. The resistance to these fluids is Secondary coated fibre
according to IEC60811-2-1. The cable is reinforced with a
steel wire braiding between the two sheaths. Strength Water swellable material
elements of glass yarn around the cable core allow easy
installation of long lengths. The 0.9 mm tight buffer is easy to Glass yarn
strip allowing fast and reliable splicing and connector
mounting. Each fibre is colour coded for easy identification. Inner sheath
The outer sheath is marked to show fibre type and cable type.
Steel wire braiding

Outer sheath

Weight and dimensions


Number of fibres Secondary coating Outer diameter Weight Tensile strength*
[Inst./oper.]
[mm] [mm] [kg/km] [N]
4 0.9 8.2 90 700/250
8 0.9 9.4 125 800/350
12 0.9 10.3 145 1200/500
24 0.9 12.0 185 1700/750

Cable properties
*Tensile strength (IEC 60794-1-2E1) Temperature window
Max tensile load during installation See above Operation -40C to +70C
Max tensile load during operation See above Installation -10C to +70C
Storage -40C to +70C
Crush (IEC 60794-1-2E3) 2000 N/10cm Water tightness* (IEC 60794-1-2F5B) < 3 m/24 hours
Impact (IEC 60794-1-2E4) 1 impacts, 25J Fire and smoke classifications
Torsion (IEC 60794-1-2E7) 1 turn/1m IEC 60332-1
IEC 60332-3-22 (Cat. A)
Cable bending IEC 60332-3-24 (Cat. C)
Minimum bending diameter 15x outer diameter IEC 61034
Cable bend (IEC 60794-1-2E11) <0.5 dB/ 5 turn IEC 60754-1
Flexibility (IEC 60794-1-2E8) 1000 cycles IEC 60754-2
Chemical reistance
Mineral oils IRM 902 (IEC60811-2-1) - 7 days/23C
- 4 hours/70C
Diesel - IRM 903 (IEC60811-2-1) - 7 days/23C
- 4 hours/70C
*) Steel wire braiding is not watertight.

www.drakaMOG.com
161
D92aici.e20
12.09.2007 14:51
Page 2 of 2

Flame retardant AICI-I/O/RM-W


Ordering information
9/125 fibre(SMF652D), Black** 50/125 fibre(MMF50HiCap), Black** 62.5/125 fibre(MMF62HiCap), Black**
Part no. Cable code Part no. Cable code Part no. Cable code
695420 G4-9/125 AICI-I/O/RM-W 695422 G4-50/125 AICI-I/O/RM-W 695424 G4-62.5/125 AICI-I/O/RM-W
695440 G8-9/125 AICI-I/O/RM-W 695442 G8-50/125 AICI-I/O/RM-W 695444 G8-62.5/125 AICI-I/O/RM-W
695450 G12-9/125 AICI-I/O/RM-W 695452 G12-50/125 AICI-I/O/RM-W 695454 G12-62.5/125 AICI-I/O/RM-W
695480 G24-9/125 AICI-I/O/RM-W 695482 G24-50/125 AICI-I/O/RM-W 695484 G24-62.5/125 AICI-I/O/RM-W
**)-Standard colour of outer sheath
We reserve the right to alter this specification without notice.

Optical fibres
Fibre type HiCap MaxCap HiCap 62.5/125
9/125 50/125 50/125
Reference(DNK) SMF652D MMF50HiCap MMF50MaxCap MMF62HiCap
IEC60793-2-50 category B.1.3 A1a A1a.2 A1b
IEC11801 classification OS1 and OS2 OM2 OM3 OM1
ITU-T type G652.D G651 G651 -

Gigabit Ethernet maximum


distances
SX-serial(850 nm) 750 m 900 m 500 m
LX-serial(1310 nm) 5000m 2000 m 550 m 1000 m
10Gigabit Ethernet maximum
distances
SX-serial(850 nm) 110 m 300 m 65 m
LX-serial(1310 nm) 10000 m
Core diameter See mode field diameter 50 2.5 m 50 2.5 m 62.5 2.5 m
Mode field diameter 1310 nm 9.2 0.4 m
1550 nm 10.3 0.5 m
Cladding diam. loose tube 125 0.7 m 125 2.0 m 125 2.0 m 125 2.0 m
Cladding diam. tight buffer 125 0.7 m 125 2.0 m 125 2.0 m 125 2.0 m
Primary coating diameter 242 7 m 250 m 250 m 250 m
(nominal)
Attenuation
(Typical values)
850 nm 2.5 dB/km 2.5 dB/km 3.0 dB/km
1300 nm 0.7 dB/km 0.7 dB/km 0.7 dB/km
1310 nm 0.33 0.37 dB/km
1550 nm 0.19 0.23dB/km
Attenuation
(Maximum values)
850 nm 2.7 dB/km 2.7 dB/km 3.2 dB/km
1300 nm 0.8 dB/km 0.9 dB/km 1.0 dB/km
1310 nm 0.40 dB/km
1550 nm 0.25 dB/km
Bandwidth(OFL*)
850 nm >600 MHzkm >1500 MHzkm >200 MHzkm
1300 nm >1200 MHzkm >500 MHzkm >600 MHzkm
Chromatic Dispersion
1285-1330 nm 3 ps/nmkm
1550 nm 18 ps/nmkm
Polarization Mode Disp.
PMD Link Design Value ** 0.06 km
Max. Individual Fibre 0.1 km
Numerical aperture 0.13 ( nominal) 0.200 0.015 0.200 0.015 0.275 0.015
Minimum permanent bending
diameter 50 mm 50 mm 50 mm 50 mm
* Over Filled Launch methode(OFL). Modal Bandwidth in accordance with IEC60793-1-41. Rev: 09/07

** According to IEC 60794-3, Ed.3 (Q=0.01%)

Other fibre types and qualities are available on request.

www.drakaMOG.com
162
Cat. 5e SF/UTP 4x2x0.51 (AWG 24) FRNC-C
Shielded 100 Data cable ISO/IEC 11801 CAT-5e
Standards applied

International ISO/IEC 11801 2nd ed.


USA ANSI/EIA/TIA 568A
Europe NEN-EN 50173

Cat 5e NEN 11156-5 (IEC 61156)


Construction NEN-EN 50288-2-1

Application Fire Rating Standards


Primary (Campus), Secondary (Riser), Tertiary Halogen Free IEC 60754-2
(Horizontal) IEEE 802.3: 10Base-T; 100Base-T; Low smoke IEC 61034-1,2
1000Base-T; IEEE 802.5 16 MB; ISDN; TPDDI; Flame propogation IEC 60332-1
ATM Fire retardant IEC 60332-3-24 (cat. C)

Construction

Conductor Bare copper wire 0.51 mm (AWG24)


Insulation Polyethylene, 1.1 mm
Twisting 2 cores to the pair
Cable la yup 4 pair to the core
Overall sheath Al-laminated plastic foil and Copper braid, tinned (coverage > 40%)
Sheath LSHF, grey RAL 7035
Sheath marking DRAKA COMTEQ MULTIMEDIA SF/UTP CAT-5e 4x2x0.51

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1 white/blue and blue,
Pair 2 white/orange and orange,
Pair 3 white/green and green,
Pair 4 white/brown and brown

Technical Data
No. of cores Weight of
Prod.number Outer Fire Load Copper Tensile
Designation and cable
Draka Comteq diameter content force
cond.area approx.
(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N)
e
CD7677530 SF/UTP Cat.5 FRNC-C 2x2x0.51 6.4 433 0.120 47 27 120

163
Mechanical Properties
Bending radius 25 mm without load
50 mm with load
Temperature range, during operation -20C upto + 60C
during installation 0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance 190 /km
Resistance unbalance 2%
Insulation resistance (500 V) 2000 M *km
Capacitance at 800 Hz nom. 48 nF/km
Capacitance unbalance (pair to ground) 1500 pF/km
Characteristic impedance (1-100 MHz) (100 15)
Nominal velocity of propagation approx. 67 %
Propagation delay 535 ns/100m
Delay skew 20 ns/100m
Test voltage (DC, 1 min) 1000 V
Core/Core and Core/Screen
Transfer impedance at 1 MHz 20 m /m
at 10 MHz 20 m /m
at 30 MHz 30 m /m
at 100 MHz 60 m /m

Nominal transmission characteristics acc. to Category 5e (at 20 C)


f Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss
(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)

1.0 1.9 71 68 69.1 66.1 68 65 20


4.0 3.7 62 59 58.3 55.3 56 53 23
10.0 6.0 56 53 50.0 47.0 48 45 25
16.0 7.6 53 50 45.4 42.4 44 41 25
20.0 8.5 51 48 42.5 39.5 42 39 25
31.2 10.7 49 46 38.3 35.3 38 35 24
62.5 15.7 44 41 28.3 25.3 32 29 22
100.0 19.8 41 38 21.2 18.2 28 25 20
125.0 22.3 40 37 17.7 14.7 26 23 19
155.5 24.2 38 35 13.8 10.8 24 21 -
175.0 25.7 37 34 11.3 8.3 23 20 -
200.0 27.5 36 33 8.5 5.5 22 19 -
250.0 29.2 35 32 5.8 2.8 20 17 -
300.0 32.0 34 31 2.0 -1.0 16 13 -

www.DrakaMOG.com

164 Datacomm12_Jan_07
Cat. 7 S/FTP 4x2x0.42 (AWG 27/7) Patch LSHF
Shielded 100 Data Patchcable ISO/IEC 11801 CAT-7
Standards applied

International ISO/IEC 11801 2nd ed.


USA ANSI/EIA/TIA 568A
Europe NEN-EN 50173

Cat 7 NEN 11156-5 (IEC 61156)


Construction NEN-EN 50288-2-1

Application Fire Rating Standards


Tertiary (Horizontal) Halogen Free IEC 60754-2
IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; Low smoke IEC 61034-1,2
10Gbase-T; IEEE 802.5 16MB; ISDN; TPDDI; Flame propogation IEC 60332-1
ATM

Construction

Conductor Bare copper wire 0.42 mm (AWG27/7)


Insulation Foam-skin Polyethylene, 0.98 mm
Pair screen Al-laminated plastic foil
Twisting 2 cores to the pair
Cable lay up 4 pair to the core
Overall sheath Copper braid, tinned (ca. 45% coverage)
Sheath LSHF, orange

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1 white/blue and blue,
Pair 2 white/orange and orange,
Pair 3 white/green and green,
Pair 4 white/brown and brown

Technical Data
No. of cores Weight of
Prod.number Outer Fire Load Copper Tensile
Designation and cable
Draka Comteq diameter content force
cond.area approx.
(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N)

CD7677650 S/FTP Cat.7 AWG27/7 PiMF 2x2x0.42 5.9 349 0.097 39 24 100

165
Mechanical Properties
Bending radius 25 mm without load
50 mm with load
Temperature range, during operation -20C upto + 60C
during installation 0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance 340 /km
Resistance unbalance 3%
Insulation resistance (500 V) 2000 M *km
Capacitance at 800 Hz nom. 43 nF/km
Capacitance unbalance (pair to ground) 1500 pF/km
Characteristic impedance (1-100 MHz) (100 15)
(100-250 MHz) (100 18)
(250-600 MHz) (100 25)
Nominal velocity of propagation approx. 79 %
Propagation delay 427 ns/100m
Delay skew 12 ns/100m
Test voltage (DC, 1 min) 1000 V
Core/Core and Core/Screen
Transfer impedance at 1 MHz 25 m /m
at 10 MHz 15 m /m
at 30 MHz 30 m /m

Nominal transmission characteristics acc. to Category 7 (at 20 C)


f Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss
(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)
1.0 0.3 90 87 90 80 77 77 23
4.0 0.6 90 87 89 80 77 77 24
10.0 1.0 90 87 89 80 77 77 25
16.0 1.3 90 87 89 76 73 73 25
20.0 1.4 90 87 89 74 71 71 25
31.2 1.8 90 87 88 70 67 67 25
62.5 2.6 90 87 87 64 61 61 23
100.0 3.2 87 84 84 60 57 57 21
125.0 3.6 85 82 81 58 55 55 20
155.5 4.0 84 81 80 56 53 53 19
175.0 4.3 83 80 79 55 52 52 19
200.0 4.6 82 79 77 54 51 51 18
250.0 5.1 81 78 76 52 49 49 18
300.0 5.6 80 77 74 50 47 47 17
450.0 6.9 77 74 70 47 44 44 17
600.0 7.9 75 72 67 44 41 41 17
750.0 8.7 73 70 64 42 39 39 -
900.0 9.7 72 69 62 41 38 38 -
1000.0 10.2 71 68 61 40 37 37 -

166
www.DrakaMOG.com
Cat. 7 S/FTP 4x2x0.56 (AWG 23) LSHF
Shielded 100 Data cable ISO/IEC 11801 CAT-7
Standards applied

International ISO/IEC 11801 2nd ed.


USA ANSI/EIA/TIA 568A
Europe NEN-EN 50173

Cat 7 NEN 11156-5 (IEC 61156)


Construction NEN-EN 50288-2-1

Application Fire Rating Standards


Primary (Campus), Secondary (Riser), Tertiary Halogen Free IEC 60754-2
(Horizontal) IEEE 802.3: 10Base-T; 100Base-T; Low smoke IEC 61034-1,2
1000Base-T; 10Gbase-T; IEEE 802.5 16MB; ISDN; Flame propogation IEC 60332-1
TPDDI; ATM

Construction

Conductor Bare copper wire 0.56 mm (AWG23)


Insulation Polyethylene, 1.35 mm
Pair screen Al-laminated plastic foil
Twisting 2 cores to the pair
Cable lay up 4 pair to the core
Overall sheath Copper braid, tinned (ca. 40% coverage)
Sheath LSHF, orange
Sheath marking DRAKA COMTEQ S/FTP CAT-7 4x2x0.56

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1 white/blue and blue,
Pair 2 white/orange and orange,
Pair 3 white/green and green,
Pair 4 white/brown and brown

Technical Data
No. of cores Weight of
Prod.number Outer Fire Load Copper Tensile
Designation and cable
Draka Comteq diameter content force
cond.area approx.
(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N)

CD7679365 S/FTP Cat.7 AWG23 PiMF 2x2x0.56 7.0 590 0.170 65 26 110

167
Mechanical Properties
Bending radius 40 mm without load
80 mm with load
Temperature range, during operation -20C upto + 60C
during installation 0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance 165 /km
Resistance unbalance 2%
Insulation resistance (500 V) 2000 M *km
Capacitance at 800 Hz nom. 43 nF/km
Capacitance unbalance (pair to ground) 1500 pF/km
Characteristic impedance (1-100 MHz) (100 15)
(100-250 MHz) (100 18)
(250-600 MHz) (100 25)
Nominal velocity of propagation approx. 79 %
Propagation delay 427 ns/100m
Delay skew 12 ns/100m
Test voltage (DC, 1 min) 1000 V
Core/Core and Core/Screen
Transfer impedance at 1 MHz 20 m /m
at 10 MHz 30 m /m
at 30 MHz 40 m /m
at 100 MHz 200 m /m

Nominal transmission characteristics acc. to Category 7 (at 20 C)


f Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return loss
(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB/100m) (dB)
1.0 1.8 100 97 98 95 105 105 -
4.0 3.4 100 97 97 94 105 102 27
10.0 5.4 100 97 95 92 97 94 30
16.0 6.8 100 97 93 90 93 90 30
20.0 7.7 100 97 92 89 91 88 30
31.2 9.6 100 97 90 87 87 84 30
62.5 13.7 100 97 86 83 81 78 30
100.0 17.4 100 97 83 80 77 74 30
125.0 19.5 95 92 75 72 75 72 26
155.5 21.9 94 91 72 69 73 70 26
175.0 23.3 93 90 70 67 72 69 25
200.0 25.0 92 89 67 64 71 68 25
250.0 28.1 90 87 62 59 69 66 24
300.0 30.9 89 86 58 55 67 64 24
450.0 38.3 87 84 48 45 64 61 23
600.0 44.8 85 82 40 37 61 58 22
750.0 52.0 83 80 31 28 59 56 21
900.0 59.4 82 79 23 20 58 55 20
1000.0 63.1 80 77 17 14 57 54 20

168
www.DrakaMOG.com
D91qfci.e28
Page 1 of 2

Fire resistant QFCI-I/O/RM-JM/- F1


Indoor and outdoor.
Fire resistant
Flame retardant halogen-free
Loose tube

QFCI-I/O/RM-JM/-
NEK 606 Code F1

Optical cable for indoor and outdoor use in vital communication and
emergency systems that need to be operational during fire. The
cable has a patented design that ensures operation for more than 3
hours in fires up to 1000C. The cable is halogen free and flame Fibres in mica wrapped
retardant to protect against secondary damage to electronic loose tube

equipment during and after fire. Outer sheath is made from black Steel strength element
UV-stabilized and weather resistant material and may be exposed Wrapping
for shorter periods to fluids such as diesel and mineral oils. The Inner sheath
resistance to these fluids is according to IEC60811-2-1. The cable
Filler
is reinforced with a steel wire braiding. The fibres are protected in
jelly filled loose tubes stranded around a central strength member Steel wire braiding

to ensure optimum performance and long life. Each fibre and loose Outer sheath

tube is colour coded for easy identification during splicing and


termination. The outer sheath is marked to show fibre type and
cable type.

Weight and dimensions


Number of Number of Number of Loose tube Outer Weight Heat release
fibres fibres in each tubes + fillers diameter diameter
tube (mm) (mm) (kg/km) (MJ/km)
4 2 2+4 2.2 13.5 260 1390
8 4 2+4 2.2 13.5 260 1381
12 4 3+3 2.2 13.5 260 1324
24 4 6+0 2.2 13.5 260 1138
48 8 6+0 2.2 13.5 260 1138
Other fibre counts are available on request.

Cable properties
Tensile strength (IEC 60794-1-2E1) Chemical reistance
Max tensile load during installation 1500 N Mineral oils IRM 902 (IEC60811-2-1) - 7 days/23C
Max tensile load during operation 500 N - 4 hours/70C
Diesel - IRM 903 (IEC60811-2-1) - 7 days/23C
- 4 hours/70C
Crush (IEC 60794-1-2E3) 3000 N/10cm Fire and smoke classifications
Impact (IEC 60794-1-2E4) 30J IEC 60331-25 (750C, 90 minutes) <1.0 dB excess loss
Torsion (IEC 60794-1-2E7) 1 turn/1m Upgraded IEC 60331-25 (1000C, 3 hours) <1.5 dB excess loss
Cable bending BP GS 112-2 Clause7.1
Minimum bending diameter 250 mm IEC 61034
Cable bend (IEC 60794-1-2E11) <0.1dB/ 5 turn IEC 60332-3-22 (Cat. A)
IEC 60332-3-24 (Cat. C)
Temperature window IEC 60754-1
Operation -40C to +70C IEC 60754-2
Installation -10C to +70C
Storage -40C to +70C

www.drakaMOG.com
169
D91qfci.e28
Page 2 of 2

Fire resistant QFCI-I/O/RM-JM/- F1


Ordering information
9/125 fibre(SMF652D), Black* 50/125 fibre(MMF50HiCap), Black* 62.5/125 fibre(MMF62HiCap), Black*
Part no. Cable code Part no. Cable code Part no. Cable code
694124 G4-62.5/125 QFCI-I/O/RM-JM/-
694144 G8-62.5/125 QFCI-I/O/RM-JM/-
694150 G12-9/125 QFCI-I/O/RM-JM/- 694152 G12-50/125 QFCI-I/O/RM-JM/- 694154 G12-62.5/125 QFCI-I/O/RM-JM/-
694180 G24-9/125 QFCI-I/O/RM-JM/- 694182 G24-50/125 QFCI-I/O/RM-JM/- 694184 G24-62.5/125 QFCI-I/O/RM-JM/-
694139 G48-9/125 QFCI-I/O/RM-JM/- 694169 G48-50/125 QFCI-I/O/RM-JM/- 694189 G48-62.5/125 QFCI-I/O/RM-JM/-
*)-Standard colour of outer sheath
We reserve the right to alter this specification without notice.

Optical fibres
Fibre type HiCap MaxCap HiCap 62.5/125
9/125 50/125 50/125
Reference(DNK) SMF652D MMF50HiCap MMF50MaxCap MMF62HiCap
IEC60793-2-50 category B.1.3 A1a A1a.2 A1b
IEC11801 classification OS1 and OS2 OM2 OM3 OM1
ITU-T type G652.D G651 G651 -

Gigabit Ethernet maximum


distances
SX-serial(850 nm) 750 m 900 m 500 m
LX-serial(1310 nm) 5000m 2000 m 550 m 1000 m
10Gigabit Ethernet maximum
distances
SX-serial(850 nm) 110 m 300 m 65 m
LX-serial(1310 nm) 10000 m
Core diameter See mode field diameter 50 2.5 m 50 2.5 m 62.5 2.5 m
Mode field diameter 1310 nm 9.2 0.4 m
1550 nm 10.3 0.5 m
Cladding diam. loose tube 125 0.7 m 125 2.0 m 125 2.0 m 125 2.0 m
Cladding diam. tight buffer 125 0.7 m 125 2.0 m 125 2.0 m 125 2.0 m
Primary coating diameter 242 7 m 250 m 250 m 250 m
(nominal)
Attenuation
(Typical values)
850 nm 2.5 dB/km 2.5 dB/km 3.0 dB/km
1300 nm 0.7 dB/km 0.7 dB/km 0.7 dB/km
1310 nm 0.33 0.37 dB/km
1550 nm 0.19 0.23dB/km
Attenuation
(Maximum values)
850 nm 2.7 dB/km 2.7 dB/km 3.2 dB/km
1300 nm 0.8 dB/km 0.9 dB/km 1.0 dB/km
1310 nm 0.40 dB/km
1550 nm 0.25 dB/km
Bandwidth(OFL*)
850 nm >600 MHzkm >1500 MHzkm >200 MHzkm
1300 nm >1200 MHzkm >500 MHzkm >600 MHzkm
Chromatic Dispersion
1285-1330 nm 3 ps/nmkm
1550 nm 18 ps/nmkm
Polarization Mode Disp.
PMD Link Design Value ** 0.06 km
Max. Individual Fibre 0.1 km
Numerical aperture 0.13 ( nominal) 0.200 0.015 0.200 0.015 0.275 0.015
Minimum permanent bending
diameter 50 mm 50 mm 50 mm 50 mm
* Over Filled Launch methode(OFL). Modal Bandwidth in accordance with IEC60793-1-41. Rev: 09/07

** According to IEC 60794-3, Ed.3 (Q=0.01%)

Other fibre types and qualities are available on request.

www.drakaMOG.com
170
S611T MARINE FIBER OPTIC CABLE
Fiber Optic Cable - Tight buffer construction

Standards applied

Construction IEC 60794-1,2,3


Performance requir. IEEE 802.3z (Gigabit Ethernet)

Application Fire Rating Standards


The Draka S611T series of Marine and Offshore Halogen Free IEC 60754-1,2
fiber optic cables is designed especially for the Low smoke IEC 61034-1,2
harsh environments of commercial marine vessels, Flame propagation IEC 60332-1-25
oil platforms and other similar applications. Draka Toxicity NES 713
S611T low smoke/zero halogen, flame retardant Fire retardant IEC 60332-3-22 (Cat.A)
cables offer the versatility and ease of use of our IEEE 1202
other offshore cables in a construction suited for
marine applications. They are complaint with the
Approvals
latest IEC requirements. S611T cables meet the
requirements of IEC 60793-1 and IEC 60793-2 Det Norske Veritas Certificate E-7154
specifications, are encapsulated in all dielectric, (DNV)
tight buffered construction, individually reinforced American Bureau of Certificate 01-NY6461-X
with aramid yarns and jacketed (breakout style). Shipping (ABS)
The break-out components are cabled around a Lloyds Registry of Certificate 00/00157E1
central member providing additional tensile Shipping (LR)
strength to the entire construction. The
thermoplastic low smoke/ zero halogen jacketing
system offers good resistance to chemicals, fluids,
fungus and abrasion. This product is also available
in an armoured version.

Construction

Possible fibre types; 62.5 m MULTIMODE, 50 m MULTIMODE, 200 m


Fibre
MULTIMODE or 8.3 m SIGNLEMODE.
Multimode or singlemode fibres with an easily-strippable 900 m tight buffered
Cladding
colored per TIA/EIA 598.
Tight buffered tubes stranded around a central strength member of dielectric
Cable lay up
material (epoxy/fibreglass rod).
Tube filling Subunit strength member of aramid yarn.
Tube LSHF, colored acc. to TIA/EIA 598.
Overall wrapping PET-foil
Sheath LSHF, black
Fiber performance
171
62.5m 50m 200m 8.3m
MULTIMODE MULTIMODE MULTIMODE SINGLEMODE
Fiber Designation 62X 50H 200S 010X
Application specs. IEC 60793-2 Type ITU G.651 & IEC ITU G.651 & IEC ITU G.652 C & D
A1b 60793-2 Type A1a 60793-2 Type A1a req. & IEC 60793-2
Type B1.1
Fiber type Graded Index Graded Index Step Index Matched Clad
Core diameter 62.5m + 2.5m 50m + 2.5m 200m + 5m 8.3m Nominal
Cladding diameter 125m + 1m 125m + 1m 230m + 10m 125m + 1m
Coating diameter 242m + 7m 242m + 7m 500m + 30m 242m + 7m
Buffer diameter 900m + 50m 900m + 50m 900m + 50m 900m + 50m
Numerical aperture 0.275 + 0.015 0.200 + 0.015 0.37 nominal N/A
Mode field diameter N/A N/A N/A 9.1m + 0.4m
Attenuation 820 Nm N/A N/A < 12.0 dB/km N/A
850 Nm < 3.5 dB/km < 3.5 dB/km N/A N/A
1300 Nm < 1.0 dB/km < 1.0 dB/km N/A < 0.70 dB/km
1550 Nm N/A N/A N/A < 0.70 dB/km
Bandwidth 820 Nm N/A N/A < 20 MHz/km N/A
850 Nm < 200 MHz/km < 500 MHz/km N/A N/A
1300 Nm < 500 MHz/km < 500 MHz/km N/A N/A
Dispersion 1285-1330 Nm N/A N/A N/A < 3.0 ps/nm.km
1550 Nm N/A N/A N/A < 18 ps/nm.km
Proof test 100,000 psi 100,000 psi 150,000 psi 100,000 psi

Mechanical Properties
Temperature range, during installation -10C to +60C
during operation -20C to +80C
storage -40C to +80C
Crush (IEC 60794-1-2E3) 3000 N/10cm
Impact (IEC 60794-1-2E4) 20 impacts, 5J
Torsion (IEC 60794-1-2E7) + 1 turn/2 m, 100 cycles
Cable bending, Cable bend < 0.1 dB / + 6 turns
(IEC 60794-1-2E11)

Technical Data
Prod.number Draka Number of Weight of
INSTALLATION OPERATING Outer diameter
Comteq fibers cable approx.
Pull strength Bend radius Tension Bend radius

(N) (mm) (N) (mm) (mm) (N)

S611T-02R-xxy 2 600 12.8 200 6.4 6.4 45


S611T-04-xxy 4 600 14.6 200 7.3 7.3 51
S611T-06-xxy 6 600 17.0 200 8.5 8.5 71
S611T-08-xxy 8 600 19.4 200 9.7 9.7 93
S611T-10-xxy 10 600 22.0 200 11.0 11.0 119
S611T-12-xxy 12 600 24.4 200 12.2 12.2 149
S611T-16-xxy 16 2700 25.7 600 12.8 12.8 150
S611T-18-xxy 18 2700 25.7 600 12.8 12.8 148
S611T-24-xxy 24 2700 29.6 600 14.8 14.8 356
S611T-36-xxy 36 2700 34.0 600 17.0 17.0 484
S611T-48-xxy 48 2700 46.0 600 23.1 23.0 600
Replace the xxy with the Fiber designation in the fiber performance table above
NOTE: Fibers are not suitable for F07 crimp and cleave connector
Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications

www.DrakaMOG.com
172
S670T ARMOURED MARINE FIBER OPTIC CABLE
Fiber Optic Cable Armoured tight buffer construction

Standards applied

Construction IEC 60794-1,2,3


Performance requir. IEEE 802.3z (Gigabit Ethernet)

Application Fire Rating Standards


The Draka S670T series of Marine and Offshore Halogen Free IEC 60754-1,2
fiber optic cables is designed especially for the Low smoke IEC 61034-1,2
harsh environments of commercial marine vessels, Flame propagation IEC 60332-1-25
oil platforms and other similar applications. Draka Toxicity NES 713
S670T low smoke/zero halogen, flame retardant Fire retardant IEC 60332-3-22 (Cat.A)
cables offer the versatility and ease of use of our IEEE 1202
other offshore cables in a construction suited for
marine applications. They are complaint with the
Approvals
latest IEC requirements. S670T cables meet the
requirements of IEC 60793-1 and IEC 60793-2 Det Norske Veritas Certificate E-7155
specifications, are encapsulated in all dielectric, (DNV)
tight buffered construction, individually reinforced American Bureau of Certificate 01-NY6461-X
with aramid yarns and jacketed (breakout style). Shipping (ABS)
The thermoplastic low smoke/ zero halogen Lloyds Registry of Certificate 00/00157E1
jacketing system offers good resistance to Shipping (LR)
chemicals, fluids, fungus and abrasion. This
product is also available in a non-armoured
version.

Construction

Possible fibre types; 62.5 m MULTIMODE, 50 m MULTIMODE, 200 m


Fibre
MULTIMODE or 8.3 m SIGNLEMODE.
Multimode or singlemode fibres with an easily-strippable 900 m tight buffered
Cladding
colored per TIA/EIA 598.
Tight buffered tubes stranded around a central strength member of dielectric
Cable lay up
material (epoxy/fibreglass rod).
Tube filling Subunit strength member of aramid yarn.
Tube LSHF, colored acc. to TIA/EIA 598.
Overall wrapping PET-foil under a filling of aramid yarns
Inner sheath LSHF, black
Overall screen Bare bronze wire braiding in acc. with IEEE 1580(2001)
Outer sheath LSHF, black

173
Fiber performance
62.5m 50m 200m 8.3m
MULTIMODE MULTIMODE MULTIMODE SINGLEMODE
Fiber Designation 62X 50H 200S 010X
Application specs. IEC 60793-2 Type ITU G.651 & IEC ITU G.651 & IEC ITU G.652 C & D
A1b 60793-2 Type A1a 60793-2 Type A1a req. & IEC 60793-2
Type B1.1
Fiber type Graded Index Graded Index Step Index Matched Clad
Core diameter 62.5m + 2.5m 50m + 2.5m 200m + 5m 8.3m Nominal
Cladding diameter 125m + 1m 125m + 1m 230m + 10m 125m + 1m
Coating diameter 242m + 7m 242m + 7m 500m + 30m 242m + 7m
Buffer diameter 900m + 50m 900m + 50m 900m + 50m 900m + 50m
Numerical aperture 0.275 + 0.015 0.200 + 0.015 0.37 nominal N/A
Mode field diameter N/A N/A N/A 9.1m + 0.4m
Attenuation 820 Nm N/A N/A < 12.0 dB/km N/A
850 Nm < 3.5 dB/km < 3.5 dB/km N/A N/A
1300 Nm < 1.0 dB/km < 1.0 dB/km N/A < 0.70 dB/km
1550 Nm N/A N/A N/A < 0.70 dB/km
Bandwidth 820 Nm N/A N/A < 20 MHz/km N/A
850 Nm < 200 MHz/km < 500 MHz/km N/A N/A
1300 Nm < 500 MHz/km < 500 MHz/km N/A N/A
Dispersion 1285-1330 Nm N/A N/A N/A < 3.0 ps/nm.km
1550 Nm N/A N/A N/A < 18 ps/nm.km
Proof test 100,000 psi 100,000 psi 150,000 psi 100,000 psi

Mechanical Properties
Temperature range, during installation -10C to +60C
during operation -20C to +80C
storage -40C to +80C
Crush (IEC 60794-1-2E3) 3000 N/10cm
Impact (IEC 60794-1-2E4) 20 impacts, 5J
Torsion (IEC 60794-1-2E7) + 1 turn/2 m, 100 cycles
Cable bending, Cable bend < 0.1 dB / + 6 turns
(IEC 60794-1-2E11)

Technical Data
Prod.number Draka Number of Weight of
INSTALLATION OPERATING Outer diameter
Comteq fibers cable approx.
Pull strength Bend radius Tension Bend radius

(N) (mm) (N) (mm) (mm) (N)

S670T-02R-xxy 2 600 21.4 200 10.7 10.7 223


S670T-04-xxy 4 600 23.0 200 11.5 11.5 230
S670T-06-xxy 6 600 25.6 200 12.8 12.8 260
S670T-08-xxy 8 600 28.0 200 14.0 14.0 278
S670T-10-xxy 10 600 30.6 200 15.3 15.3 310
S670T-12-xxy 12 600 33.0 200 16.5 16.5 381
S670T-16-xxy 16 2700 34.4 600 17.2 17.2 408
S670T-18-xxy 18 2700 34.4 600 17.2 17.2 402
S670T-24-xxy 24 2700 38.0 600 19.0 19.0 484
S670T-36-xxy 36 2700 43.7 600 21.8 21.8 566
S670T-48-xxy 48 2700 58.9 600 21.8 28.9 1083
Replace the xxy with the Fiber designation in the fiber performance table above
NOTE: Fibers are not suitable for F07 crimp and cleave connector
Information is subject to change without notice. Consult factory for a variety of alternate constructions for specific applications

www.DrakaMOG.com
174
SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 100V
Profibus cable for ships and offshore units

Standards applied

Germany DIN 19245-3


Europe EN 50170-Vol.2 PROFIBUS

Application Fire Rating Standards


As a bus cable for fixed installation on board ships Halogen Free IEC 60754-2
and offshore units in all locations and on open Low smoke IEC 61031
decks. The cable is not suitable for continues use Ozone resistance IEC 61031
in water. Fire retardant IEC 60332-3-24 (cat. C)

Construction

Conductor Stranded bare copper wire 0.35 mm (AWG22/7)


Insulation Foam-skin Polyethylene (Foam-PE)
Core identification a core: red, b core: green
Cable lay up Laying of the cores with two dummies
Overall sheath PET-foil
Overall screen Laminated aluminium-foil under a copper braid, tinned
Inner sheath FRNC, 8.0 mm
Outer sheath FRNC, black 10.8 mm
Sheath marking year SIENOPYR-FR-PROFIBUS M-02Y(St)CHX 1x2x0,35 mm 100V, 150

Technical Data
No. of cores
Prod.number Outer Weight of Copper
Designation and Tensile force
Draka Comteq diameter cable approx. content
cond.area
(mm2) (mm) (kg/km) (kg/km) (N)

CD7677650 SIENOPYR-FR-PROFIBUS 1x2x0.35 10.8 70

175
Mechanical Properties
Bending radius 100 mm without load
200 mm with load
Temperature range, during operation -40C upto + 80C
during installation -10C upto + 50C
Resistance to chemicals Diesel fuel to DIN VDE 51601
(test to VG 95218 part 2) ASTM oil No. 2 to DIN 53521
Oils, NATO code 0-178, BW-TL 9150-0031/2 to VG 95214 part 4
Hydraulic fluids, NATO code H-515, BW-TL 9150-0020 to VG
95214 part 4
Solvent cleansing agents, BW-TL 6850-0017 to VG 95214 part 4
De-ionized water to VG 95214 part 4
De-ionized water with 3,5% NaCl.

Electrical Properties (at 20C 5C)


DC loop resistance 110 /km
Mutual capacitance (at 800 Hz) 30 nF/km
Characteristic impedance (at 9.6 kHz) (250 25)
. (at 38.4 kHz) (185 18.5)
. (3-20 MHz) (150 15)
Insultion resistance > 16 G.km
Nominal voltage 110 Veff

Nominal transmission characteristics (at 20 C)


f Attenuation
(MHz) (dB/100m)
0.0096 0.3
0.0384 0.5
4.0 2.2
16.0 4.5

www.DrakaMOG.com

Datacomm01_Jan_07

176
ToughCat S/STP 4x2x0,6 (AWG 24/7) LSHF-FR
Shielded 100 Data cable ISO/IEC 11801 CAT-5e
Standards applied

International ISO/IEC 11801 2nd ed.


USA ANSI/EIA/TIA 568A
Europe NEN-EN 50173
Cat 5e NEN 11156-5 (IEC 61156)
Construction NEN-EN 50288-2-1
Oil-resistance CEI 20.34 4h 70C IRM902

Application Fire Rating Standards

This Cat.5e S/STP cable is meant for use as Halogen Free IEC 60754-2
horizontal cable in tougher electrical and has Low smoke IEC 61034-1,2
stranded copper conductors arranged in Flame propogation IEC 60332-1
individually foil screened twisted pairs. All four pairs Fire retardant IEC 60332-3-24 (cat. C)
have a common braid. The susceptibility of noise is Specifications
very low because of excellent shielding
performance. Because of this, the cable can also Det Norske Veritas (DNV)
be used in Class F (Cat.7) installations up to 70 m. Lloyds Registar (LR)
Permanent links. Germanischer Lloyds (GL)

Construction

Conductor Bare copper wire 0.60 mm (AWG24/7)


Insulation Polyethylene, 1.4 mm
Twisting 2 cores to the pair
Pair screen 4 pairs
Cable lay up Al-laminated plastic foil around each pair
Overall sheath Copper braid, tinned
Sheath Oil resistant, fire retardant and halogen free LSHF-FR, grey RAL 7035

Core identification
(in accordance ISO/IEC 11801 2nd edition)
Pair 1 white/blue and blue,
Pair 2 white/orange and orange,
Pair 3 white/green and green,
Pair 4 white/brown and brown

Technical Data
No. of cores Weight of
Prod.number Outer Fire Load Copper Tensile
Designation and cable
Draka Comteq diameter content force
cond.area approx.
(mm2) (mm) (MJ/km) (kWh/m) (kg/km) (kg/km) (N)

CNS792621 ToughCat S-STP LSHF-FR 2x2x0.60 7.8 462 0.128 44 33 100

177
Mechanical Properties
Bending radius 25 mm without load
50 mm with load
Temperature range, during operation -20C upto + 85C
during installation 0C upto + 50C

Electrical Properties (at 20C 5C)


DC loop resistance 158 /km
Resistance unbalance 2%
Insulation resistance (500 V) 2000 M *km
Capacitance at 800 Hz nom. 43 nF/km
Capacitance unbalance (pair to ground) 1500 pF/km
Characteristic impedance (1-100 MHz) (100 15)
(100-250 MHz) (100 18)
Nominal velocity of propagation approx. 75 %
Propagation delay 450 ns/100m
Delay skew 15 ns/100m
Test voltage (DC, 1 min) 1000 V
Core/Core and Core/Screen
Transfer impedance at 1 MHz 10 m /m
at 10 MHz 8 m /m
at 30 MHz 10 m /m

Nominal transmission characteristics acc. to Category 7 (at 20 C)


f Attenuation NEXT PS-ACR PS-NEXT ELFEXT PS-ELFEXT Return loss
(MHz) (dB/100m) (dB) (dB) (dB/100m) (dB/100m) (dB/100m) (dB)
1.0 2.1 90 85 87 85 82 23
4.0 4.0 90 83 87 85 82 24
10.0 6.3 90 81 87 79 76 25
16.0 8.0 90 79 87 75 72 25
20.0 9.0 90 78 87 73 70 25
31.2 11.4 90 76 87 69 66 25
62.5 16.5 86 67 83 63 60 23
100.0 21.3 83 59 80 59 56 21
125.0 24.2 81 54 78 57 54 20
200.0 31.5 78 44 75 53 50 18
250.0 35.8 77 38 74 51 48 18
400.0 47.1 73 23 70 47 44 17
600.0 60.1 71 8 68 44 41 17

www.DrakaMOG.com

178 Datacomm13_Jan_07
Opmaak Control Cables 27-07-2001 15:16 Pagina 14

Power and control cables


HXXM EEP 0.6/1 kV IEC 60092-3
Class 2 conductors

Application: Identification of the cores:

Unarmored power and control cables 0.6/1 kV with special 1 core black
properties for electrical installations in ships and offshore 2 cores black, blue
units. Temperature Class 85 C, Flame Retardant 3 cores black, blue, brown
(IEC 60332-3 category A, A/F), Low Smoke, Halogen 4 cores black, blue, brown, green/yellow
Free, Low Toxicity. Suitable for application in cold climate 5 cores and up: black, numbered
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively.
Special cable properties:

Fire propagation: IEC 60332-3 category A, A/F


Construction: Smoke: IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
Generally according to IEC 60092-3 0.6/1 kV
Acidity: IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
Conductors: stranded bare annealed
Halogen content: IEC 60754-1/2 and MIL-C-24643A
copper, IEC 60228, (Class 2)
(par. 4.7.26)
sizes 1 - 300 mm2
Toxicity index: NES 713
Insulation: cross linked polyethylene (XLPE/
Cold properties: cold bend (40 C) and cold impact
HF XLPE) according to IEC 60092-3,
(35 C) according to CAN/CSA-C22.2
IEC 60092-351 and IEEE Std 45
No. 0.3-Dec. 92
Assembly: cores cabled together
Filler: halogen free filling compound
Sheathing: halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

14

179
Opmaak Control Cables 27-07-2001 15:16 Pagina 15

General data for HXXM EEP 0.6/1 kV EEP IEC 60092-3


Class 2 conductors
number of number of nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1 x 1.5 7 1.6 3.4 0.220 5.6 28 29 43 3.7 12.1
1 x 2.5 7 2.0 3.9 0.236 6.0 30 37 55 2.26 7.41
1x 4 7 2.5 4.6 0.268 6.8 34 50 75 1.41 4.61
1x 6 7 3.1 5.2 0.287 7.3 37 63 94 0.94 3.08
1 x 10 7 4.0 6.2 0.339 8.6 43 101 150 0.56 1.83
1 x 16 7 5.0 7.5 0.386 9.8 49 141 210 0.35 1.15
1 x 25 7 6.3 9.0 0.457 11.6 58 215 320 0.222 0.727
1 x 35 19 7.0 9.7 0.484 12.3 74 276 410 0.160 0.524
1 x 50 19 8.1 11.0 0.642 16.3 98 437 650 0.118 0.387
1 x 70 19 9.7 13.0 0.728 18.5 111 591 880 0.082 0.268
1 x 95 19 11.4 15.0 0.811 20.6 124 779 1,160 0.059 0.193
1 x 120 37 13.9 17.7 0.929 23.6 142 974 1,450 0.047 0.153
1 x 150 37 15.5 19.5 1.028 26.1 157 1,189 1,770 0.038 0.124
1 x 185 37 17.3 21.5 1.106 28.1 169 1,445 2,150 0.0302 0.0991
1 x 240 61 19.9 24.5 1.248 31.7 190 1.881 2,800 0.0230 0.0754
1 x 300 61 22.2 27.3 1.366 34.7 208 2.298 3,420 0.0183 0.0601
2x 1.5 7 1.6 3.4 0.394 10.0 50 101 150 3.7 12.1
2x 2.5 7 2.0 3.9 0.437 11.1 56 128 190 2.26 7.41
2x 4 7 2.5 4.6 0.500 12.7 76 175 260 1.41 4.61
2x 6 7 3.1 5.2 0.563 14.3 86 228 340 0.94 3.08
2x 10 7 4.0 6.2 0.661 16.8 101 329 490 0.56 1.83
2x 16 7 5.0 7.5 0.783 19.9 119 484 720 0.35 1.15
2x 25 7 6.3 9.0 0.909 23.1 139 706 1,050 0.222 0.727
2x 35 19 7.0 9.7 0.969 24.6 148 874 1,300 0.160 0.524
2x 50 19 8.1 11.0 1.079 27.4 164 1,109 1,650 0.118 0.387
2x 70 19 9.7 13.0 1.280 32.5 195 1,546 2,300 0.082 0.268
2x 95 19 11.4 15.0 1.445 36.7 220 2,083 3,100 0.059 0.193
3 x 1.5 7 1.6 3.4 0.417 10.6 53 114 170 3.7 12.1
3 x 2.5 7 2.0 3.9 0.461 11.7 59 141 210 2.26 7.41
3x 4 7 2.5 4.6 0.528 13.4 80 195 290 1.41 4.61
3x 6 7 3.1 5.2 0.594 15.1 91 262 390 0.94 3.08
3 x 10 7 4.0 6.2 0.701 17.8 107 396 590 0.56 1.83
3 x 16 7 5.0 7.5 0.815 20.7 124 564 840 0.35 1.15
3 x 25 7 6.3 9.0 0.953 24.2 145 840 1,250 0.222 0.727
3 x 35 19 7.0 9.7 1.039 26.4 158 1,075 1,600 0.160 0.524
3 x 50 19 8.1 11.0 1.165 29.6 178 1,411 2,100 0.118 0.387
3 x 70 19 9.7 13.0 1.354 34.4 206 1,915 2,850 0.082 0.268
3 x 95 19 11.4 15.0 1.547 39.3 236 2,621 3,900 0.059 0.193
3 x 120 37 13.9 17.7 1.791 45.5 273 3,326 4,950 0.047 0.153
3 x 150 37 15.5 19.5 1.976 50.2 301 4,099 6,100 0.038 0.124
3 x 185 37 17.3 21.5 2.165 55.0 330 5,006 7,450 0.0302 0.0991
3 x 240 61 19.9 24.5 2.449 62.2 373 6,518 9,700 0.0230 0.0754
4 x 1.5 7 1.6 3.4 0.461 11.7 59 134 200 3.7 12.1
4 x 2.5 7 2.0 3.9 0.504 12.8 77 168 250 2.26 7.41
4x 4 7 2.5 4.6 0.583 14.8 89 242 360 1.41 4.61
4x 6 7 3.1 5.2 0.634 16.1 97 302 450 0.94 3.08
4 x 10 7 4.0 6.2 0.772 19.6 118 484 720 0.56 1.83
4 x 16 7 5.0 7.5 0.902 22.9 137 706 1,050 0.35 1.15
4 x 25 7 6.3 9.0 1.051 26.7 160 1,008 1,500 0.222 0.727
4 x 35 19 7.0 9.7 1.130 28.7 172 1,310 1,950 0.160 0.524
4 x 50 19 8.1 11.0 1.287 32.7 196 1,747 2,600 0.118 0.387
4 x 70 19 9.7 13.0 1.504 38.2 229 2,385 3,550 0.082 0.268
4 x 95 19 11.4 15.0 1.717 43.6 262 3,293 4,900 0.059 0.193
4 x 120 37 13.9 17.7 1.992 50.6 304 4,166 6,200 0.047 0.153
4 x 150 37 15.5 19.5 2.189 55.6 334 5,107 7,600 0.038 0.124
5 x 1.5 7 1.6 3.4 0.504 12.8 77 148 220 3.7 12.1
5 x 2.5 7 2.0 3.9 0.555 14.1 85 202 300 2.26 7.41
5x 4 7 2.5 4.6 0.634 16.1 97 282 420 1.41 4.61
5 x 25 7 6.3 9.0 1.185 30.1 181 1,243 1,850 0.222 0.727
24 x 1 7 1.3 3.1 0.858 21.8 131 349 520 5.5 18.1
7x 1.5 7 1.6 3.4 0.516 13.1 79 148 220 3.7 12.1
24 x 1.5 7 1.6 3.4 0.949 24.1 145 470 700 3.7 12.1
37 x 1.5 7 1.6 3.4
180
1.102 28.0 168 672 1,000 3.7 12.1
7x 2.5 7 2.0 3.9 0.575 14.6 88 202 300 2.26 7.41
Opmaak Control Cables 27-07-2001 15:16 Pagina 16

Power and control cables


HXXM EEP 0.6/1 kV IEC 60092-3
Class 5 conductors

Application: Identification of the cores:

Unarmored power and control cables 0.6/1 kV with special 1 core black
properties for electrical installations in ships and offshore 2 cores black, blue
units. 3 cores black, blue, brown
Temperature Class 85 C, Flame Retardant (IEC 60332-3 4 cores black, blue, brown, green/yellow
category A, A/F), Low Smoke, Halogen Free, Low
Toxicity. Suitable for application in cold climate areas
Special cable properties:
required to pass cold bend and cold impact testing at
40 C and 35 C, respectively. Fire propagation: IEC 60332-3 category A, A/F
Smoke: IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
Construction: Acidity: IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
Generally according to IEC 60092-3 0.6/1 kV
Halogen content: IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.26)
Conductors: flexible bare annealed
Toxicity index: NES 713
copper, IEC 60228, (Class 5)
Cold properties: cold bend (40 C) and cold impact
sizes 1 - 300 mm2
(35 C) according to CAN/CSA-C22.2
Insulation: cross linked polyethylene (XLPE/
No. 0.3-Dec. 92
HF XLPE) according to IEC 60092-3,
IEC 60092-351 and IEEE Std 45
Assembly: cores cabled together
Filler: halogen free filling compound
Sheathing: halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

16

181
Opmaak Control Cables 27-07-2001 15:16 Pagina 17

General data for HXXM EEP 0.6/1 kV IEC 60092-3


Class 5 conductors
number of number of nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 5
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1 x 35 266 8.2 11.0 0.535 13.6 82 286 425 0.169 0.544
1 x 50 380 9.8 12.8 0.713 18.1 109 474 705 0.118 0.386
1 x 70 330 11.6 15.1 0.811 20.6 124 638 950 0.083 0.272
1 x 95 437 13.1 16.8 0.886 22.5 135 806 1,200 0.063 0.206
1 x 120 562 15.4 19.2 0.988 25.1 151 1,008 1,500 0.049 0.161
1 x 150 703 17.1 21.2 1.094 27.8 167 1,257 1,870 0.039 0.129
1 x 185 851 18.5 22.8 1.165 29.6 178 1,478 2,200 0.032 0.106
1 x 240 1,117 21.3 26.0 1.307 33.2 199 1.951 2,850 0.0244 0.0801
1 x 300 1,384 23.7 28.8 1.429 36.3 218 2.318 3,450 0.0195 0.0641
2x 35 266 8.2 11.0 1.067 27.1 163 941 1,400 0.169 0.554
2x 50 380 9.8 12.8 1.228 31.2 187 1,277 1,900 0.118 0.386
2x 70 330 11.6 15.1 1.437 36.5 219 1,767 2,630 0.083 0.272
2x 95 437 13.1 16.8 1.587 40.3 242 2,231 3,320 0.063 0.206
3 x 35 266 8.2 11.0 1.154 29.3 176 1,159 1,725 0.169 0.554
3 x 50 380 9.8 12.8 1.315 33.4 200 1,566 2,330 0.118 0.386
3 x 70 330 11.6 15.1 1.543 39.2 235 2,184 3,250 0.083 0.272
3 x 95 437 13.1 16.8 1.701 43.2 259 2,779 4,135 0.063 0.206
3 x 120 562 15.4 19.2 1.929 49.0 294 3,548 5,280 0.049 0.161
3 x 150 703 17.1 21.2 2.122 53.9 323 4,368 6,500 0.039 0.129
3 x 185 851 18.5 22.8 2.272 57.7 346 5,157 7,675 0.032 0.106
3 x 240 1,117 21.3 26.0 2.579 65.5 393 6,703 9,975 0.0244 0.0801
4 x 35 266 8.2 11.0 1.272 32.3 194 1,428 2,125 0.169 0.554
4 x 50 380 9.8 12.8 1.457 37.0 222 1,939 2,885 0.118 0.386
4 x 70 330 11.6 15.1 1.709 43.4 260 2,715 4,040 0.083 0.272
4 x 95 437 13.1 16.8 1.890 48.0 288 3,464 5,155 0.063 0.206
4 x 120 562 15.4 19.2 2.146 54.5 327 4,428 6,590 0.049 0.161
4 x 150 703 17.1 21.2 2.354 59.8 359 5,433 8,085 0.039 0.129

182
General data for HXXM-FR EEP 0.6/1 kV IEC 60092-3
Class 2 conductors
number of number of nominal nominal nominal nominal approxi approx
cores and wires in conductor core diameter diameter mate weight
nominal cross conductor diameter diameter over over weight
sectional area class 2 sheath sheath
(n x mm2) (n) (mm) (mm) (inches) (mm) (lbs/M) (kg/km)
1 x 1.5 7 1.6 4.3 0.252 6.4 35 52
1 x 2.5 7 2.0 4.7 0.272 6.9 43 64
1x 4 7 2.5 5.5 0.299 7.6 56 84
1x 6 7 3.1 6.0 0.319 8.1 71 105
1 x 10 7 4.0 7.1 0.370 9.4 107 159
1 x 16 7 5.0 8.3 0.421 10.7 151 224
1 x 25 7 6.3 9.8 0.492 12.5 223 332
1 x 35 19 7.0 10.6 0.520 13.2 287 427
1 x 50 19 8.1 11.9 0.677 17.2 455 677
1 x 70 19 9.7 13.9 0.764 19.4 612 911
1 x 95 19 11.4 15.8 0.846 21.5 804 1197
1 x 120 37 13.9 18.6 0.961 24.4 986 1467
1 x 150 37 15.5 20.3 1.059 26.9 1218 1812
1 x 185 37 17.3 22.3 1.150 29.2 1481 2204
1 x 240 61 19.9 25.4 1.283 32.6 1906 2837
1 x 300 61 22.2 28.1 1.398 35.5 2328 3464
2x 1.5 7 1.6 4.3 0.461 11.7 126 187
2x 2.5 7 2.0 4.7 0.508 12.9 158 235
2x 4 7 2.5 5.5 0.579 14.7 214 318
2x 6 7 3.1 6.0 0.630 16.0 264 393
2x 10 7 4.0 7.1 0.728 18.5 375 558
2x 16 7 5.0 8.3 0.850 21.6 534 794
2x 25 7 6.3 9.8 0.976 24.8 747 1112
2x 35 19 7.0 10.6 1.035 26.3 917 1364
2x 50 19 8.1 11.9 1.157 29.4 1184 1762
2x 70 19 9.7 13.9 1.346 34.2 1646 2450
2x 95 19 11.4 15.8 1.512 38.4 2160 3215
3 x 1.5 7 1.6 4.3 0.492 12.5 141 210
3 x 2.5 7 2.0 4.7 0.535 13.6 176 262
3x 4 7 2.5 5.5 0.614 15.6 243 361
3x 6 7 3.1 6.0 0.669 17.0 304 453
3 x 10 7 4.0 7.1 0.772 19.6 436 649
3 x 16 7 5.0 8.3 0.886 22.5 615 915
3 x 25 7 6.3 9.8 1.039 26.4 899 1338
3 x 35 19 7.0 10.6 1.110 28.2 1136 1691
3 x 50 19 8.1 11.9 1.240 31.5 1478 2200
3 x 70 19 9.7 13.9 1.425 36.2 2029 3020
3 x 95 19 11.4 15.8 1.618 41.1 2728 4060
3 x 120 37 13.9 18.6 1.862 47.3 3508 5220
3 x 150 37 15.5 20.3 2.047 52.0 4287 6380
3 x 185 37 17.3 22.3 2.236 56.8 5120 7620
3 x 240 61 19.9 25.4 2.524 64.1 6659 9910
4 x 1.5 7 1.6 4.3 0.543 13.8 169 252
4 x 2.5 7 2.0 4.7 0.583 14.8 208 309
4x 4 7 2.5 5.5 0.661 16.8 280 417
4x 6 7 3.1 6.0 0.713 18.1 348 518
4 x 10 7 4.0 7.1 0.854 21.7 540 803
4 x 16 7 5.0 8.3 0.980 24.9 758 1128
4 x 25 7 6.3 9.8 1.142 29.0 1100 1635
4 x 35 19 7.0 10.6 1.236 31.4 1378 2050
4 x 50 19 8.1 11.9 1.366 34.7 1845 2745
4 x 70 19 9.7 13.9 1.583 40.2 2554 3800
4 x 95 19 11.4 15.8 1.799 45.7 3441 5120
4 x 120 37 13.9 18.6 2.071 52.6 4368 6500
4 x 150 37 15.5 20.3 2.272 57.7 5275 7850
5x 1.5 7 1.6 4.3 0.602 15.3 204 303
5x 2.5 7 2.0 4.7 0.650 16.5 251 373
5x 4 7 2.5 5.5 0.736 18.7 349 520
24 x 1 7 1.3 3.8 1.047 26.6 504 750
6x 1.5 7 1.6 4.3 0.622 15.8 180 268
7x 1.5 7 1.6 4.3 0.626 15.9 187 278
8x 1.5 7 1.6 4.3 0.681 17.3 212 316
12 x 1.5 7 1.6 4.3 0.827 21.0 306 455
20 x 1.5 7 1.6 4.3 1.043 26.5 497 739
24 x 1.5 7 1.6 4.3 1.169 29.7 624 928
30 x 1.5 7 1.6 4.3 1.248 31.7 719 1070
37 x 1.5 7 1.6 4.3 1.358 34.5 864 1285
6x 2.5 7 2.0 4.7 0.673 17.1 227 338
7x 2.5 7 2.0 4.7 0.677 17.2 239 356
8x 2.5 7 2.0 4.7 0.744 18.9 276 411
10 x 2.5 7 2.0 4.7 0.874 22.2 346 515
12 x 2.5 7 2.0 4.7 0.906 23.0 398 593
19 x 2.5 7 2.0 4.7 1.079 27.4 605 900
20 x 2.5 7 2.0 4.7 1.150 29.2 648 964
24 x 2.5 7 2.0 4.7 1.280 32.5 816 1215
30 x 2.5 7 2.0 4.7 1.366 34.7 943 1404
36 x 2.5 7 2.0 4.7 1.488 37.8 1138 1693
13 x 6 7 3.1 6.0
183 1.209 30.7 827 1231
Opmaak Control Cables 27-07-2001 15:15 Pagina 12

Power and control cables


HXXMB EEP 0.6/1 kV IEC 60092-3
Class 5 conductors

Application: Identification of the cores:

Armored power and control cables 0.6/1 kV with special 1 core black
properties for electrical installations in ships and offshore 2 cores black, blue
units. Temperature Class 85 C, Flame Retardant (IEC 3 cores black, blue, brown
60332-3 category A, A/F), Low Smoke, Halogen Free, 4 cores black, blue, brown, green/yellow
Low Toxicity. Suitable for application in cold climate areas
required to pass cold bent and cold impact testing at
Special cable properties:
40 C and 35 C, respectively.
Fire propagation: IEC 60332-3 category A, A/F
Smoke: IEC 61034-1/2, MIL-C-24643A
Construction: (par. 4.7.27) and NES 711
Acidity: IEC 60754-1/2 and MIL-C-24643A
Generally according to IEC 60092-3 0.6/1 kV
(par. 4.7.25)
Halogen content: IEC 60754-1/2 and MIL-C-24643A
Conductors: flexible bare annealed
(par. 4.7.26)
copper, IEC 60228, (Class 5)
Toxicity index: NES 713
sizes 1 - 300 mm2
Cold properties: cold bend (40 C) and cold impact
Insulation: cross linked polyethylene (XLPE/
(35 C) according to CAN/CSA-C22.2
HF XLPE) according to IEC 60092-3,
No. 0.3-Dec. 92
IEC 60092-351 and IEEE Std 45
Assembly: cores cabled together
Filler: halogen free filling compound
Innersheath: halogen free, flame retardant
(SHF1, IEC 60092-359)
Braiding: bronze wire according to IEEE Std 45,
CDA 220, weight coverage 90% on
nominal diameter according to
IEC 60092-3, wire diameter
0.32 - 0.40 mm
Sheathing: halogen free, flame retardant (SHF1,
IEC 60092-359); all sheath and
12 jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

184
Opmaak Control Cables 27-07-2001 15:15 Pagina 13

General data for HXXMB EEP 0.6/1 kV IEC 60092-3


Class 5 conductors
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 5 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1 x 35 266 8.2 11.0 0.535 13.6 0.32 0.697 17.7 106 443 660 0.169 0.554
1 x 50 380 9.8 12.8 0.713 18.1 0.32 0.874 22.2 133 685 1,020 0.118 0.386
1 x 70 330 11.6 15.1 0.811 20.6 0.32 0.980 24.9 149 874 1,300 0.083 0.272
1 x 95 437 13.1 16.8 0.886 22.5 0.32 1.055 26.8 161 1,062 1,580 0.063 0.206
1 x 120 562 15.4 19.2 0.988 25.1 0.32 1.173 29.8 179 1,310 1,950 0.049 0.161
1 x 150 703 17.1 21.2 1.094 27.8 0.32 1.287 32.7 196 1,596 2,375 0.039 0.129
1 x 185 851 18.5 22.8 1.165 29.6 0.32 1.358 34.5 207 1,848 2,750 0.032 0.106
1 x 240 1,117 21.3 26.0 1.307 33.2 0.40 1.520 38.6 232 2,369 3,525 0.0244 0.0801
1 x 300 1,384 23.7 28.8 1.429 36.3 0.40 1.650 41.9 251 2,856 4,250 0.0195 0.0641
2x 35 266 8.2 11.0 1.067 27.1 0.32 1.260 32.0 192 1,270 1,890 0.169 0.554
2x 50 380 9.8 12.8 1.228 31.2 0.40 1.402 35.6 214 1,720 2,560 0.118 0.386
2x 70 330 11.6 15.1 1.437 36.5 0.40 1.657 42.1 253 2,301 3,425 0.083 0.272
2x 95 437 13.1 16.8 1.587 40.3 0.40 1.815 46.1 277 2,822 4,200 0.063 0.206
3 x 35 266 8.2 11.0 1.154 29.3 0.32 1.346 34.2 205 1,512 2,250 0.169 0.554
3 x 50 380 9.8 12.8 1.315 33.4 0.40 1.528 38.8 233 2,036 3,030 0.118 0.386
3 x 70 330 11.6 15.1 1.543 39.2 0.40 1.772 45.0 270 2,755 4,100 0.083 0.272
3 x 95 437 13.1 16.8 1.701 43.2 0.40 1.937 49.2 295 3,420 5,090 0.063 0.206
3 x 120 562 15.4 19.2 1.929 49.0 0.40 2.173 55.2 331 4,301 6,400 0.049 0.161
3 x 150 703 17.1 21.2 2.122 53.9 0.40 2.374 60.3 362 5,214 7,760 0.039 0.129
3 x 185 851 18.5 22.8 2.272 57.7 0.40 2.531 64.3 386 6,064 9,025 0.032 0.106
3 x 240 1,117 21.3 26.0 2.579 65.5 0.40 2.854 72.5 435 7,795 11,600 0.0244 0.0801
4 x 35 266 8.2 11.0 1.272 32.3 0.40 1.484 37.7 226 1,881 2,800 0.169 0.554
4 x 50 380 9.8 12.8 1.457 37.0 0.40 1.677 42.6 256 2,486 3,700 0.118 0.386
4 x 70 330 11.6 15.1 1.709 43.4 0.40 1.945 49.4 296 3,360 5,000 0.083 0.272
4 x 95 437 13.1 16.8 1.890 48.0 0.40 2.134 54.2 325 4,206 6,260 0.063 0.206
4 x 120 562 15.4 19.2 2.146 54.5 0.40 2.398 60.9 365 5,288 7,870 0.049 0.161
4 x 150 703 17.1 21.2 2.354 59.8 0.40 2.614 66.4 398 6,384 9,500 0.039 0.129

185
HXXM FR Power & Control cables 0.6/1 kV
Fire resistant halogen free marine cable

Max. conductor temp.: 90 C


Nominal voltage : 0.6/1 kV

Standards applied
Application

Fire resistant power and control cables for fixed Halogen Free - According to IEC 60754-1/2
installations in ships with special properties. Low smoke - According to IEC 61034-1/2
Flame retardant - According to IEC 60332-3 cat A
Toxicity index - According to NES 713
Fire resistance - According to IEC 60331

Construction

Conductor Annealed stranded circular copper


Insulation Mica tape and Crosslinked polyethylene, XLPE/HF XLPE to IEC 60092/3
Inner sheath Flame retardant halogen free thermoplastic compound, SHF1
Outer sheath Flame retardant halogen-free thermoplastic compound, SHF1
DRAKA HXXM-FR 0,6/1kV IEC 60092-3 3 x 10 mm2
Marking text
ETL Listed 9801094 (year) (code)
Outer sheath colour Grey

Identification the cores

One core Black


Two cores Black, blue
Three cores Black, blue, Brown
Four cores Black, blue. Brown, green/yellow
Five cores and up Black, numbered

186
RANGE AND DIMENSIONS
Diam Weight
No. of pairs Cross Diameter
Conductor- under of Max. Resistance Resistance
and section Corediameter outer
Prod.number diameter armour cable current at 20 oC DC at 90 oC 50
cond.area screen (mm) sheath
(mm) mm approx. (A) (Ohm/km) Hz (Ohm/km)
(mm2) (mm2) (mm)
(kg/km)
123497 3 x 10 n.a. 3.92 7.04 19.20 n.a. 635 65 0.56 2.33
123498 3 x 25 n.a. 6.27 9.80 26.00 n.a. 1316 110 0.222 0.927
123499 3 x 35 n.a. 7.00 10.57 28.20 n.a. 1685 137 0.160 0.669
123501 3 x 50 n.a. 8.10 11.88 31.50 n.a. 2195 167 0.118 0.494
123502 3 x 120 n.a. 15.40 20.02 50.80 n.a. 5415 301 0.047 0.198
123503 3 x 95 n.a. 11.40 15.81 41.10 n.a. 4045 259 0.059 0.248
123504 3 x 150 n.a. 16.90 21.67 54.70 n.a. 6475 347 0.038 0.161
123506 4 x 35 n.a. 7.00 10.57 31.40 n.a. 2120 137 0.160 0.669
123509 7 x 1,5 n.a. 1.57 4.30 15.90 n.a. 285 20 3.70 15.4
123519 3 x 16 n.a. 4.97 8.29 22.10 n.a. 895 87 0.35 1.47
123521 3 x 70 n.a. 9.7 13.90 36.20 n.a. 3010 214 0.082 0.344
124663 4x3x1 n.a. 1.29 3.81 23.10 29.7 485 n.a. 3.70 n.a.

Installation recommendations
Minimum Bending Radius Minimum Bending Maximum Tensile Load Minimum Installation
during Installation Radius Fixed Installed During Installation Temperature
50 N * total cross section
8xD 6xD -10 C
conductors

1610 Greens Road, Suite 200, Houston TX 77032


Phone: 281-209-1070, Toll Free: 888-354-2225, Fax 281-851-1433
Website: www.DrakaMOG.com
187
Opmaak Control Cables 27-07-2001 15:19 Pagina 24

Instrumentation and communication cables


HXXM EEP 0.6/1 kV IEC 60092-3
Individually shielded and isolated*

Application: Identification of the groups:

Unarmored, individually shielded and isolated instrumen- 1 pair black, white


tation and communication cables 0.6/1 kV with special multi pairs black, white
properties for electrical installations in ships and offshore (groups sequential numbered
units. Temperature Class 85 C, Flame Retardant 1-1, 2-2, 3-3 etc.)
(IEC 60332-3 category A, A/F), Low Smoke, Halogen 1 triad black, white, red
Free, Low Toxicity. Suitable for application in cold climate multi triads black, white, red
areas required to pass cold bend and cold impact testing (groups sequential numbered
at 40 C and 35 C, respectively. 1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:


Construction:
Fire propagation: IEC 60332-3 category A, A/F
According to IEC 60092-3 with enhanced properties.
Smoke: IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
Conductors: stranded bare annealed
Acidity: IEC 60754-1/2 and MIL-C-24643A
copper, IEC 60228, sizes 1 - 4 mm2
(par. 4.7.25)
Insulation: cross linked polyethylene (XLPE/
Halogen content: IEC 60754-1/2 and MIL-C-24643A
HF XLPE) according to IEC 60092-3,
(par. 4.7.26)
IEC 60092-351 and IEEE Std 45
Toxicity index: NES 713
Twisting: cores twisted to a pair/triad
Cold properties: cold bend (40 C) and cold impact
Individual shield tinned copper drain wire; alumi-
(35 C) according to CAN/CSA-C22.2
and isolation: num/polyester tape; polyester tape
No. 0.3-Dec. 92
Assembly: shielded pairs/triads cabled together
Sheathing: halogen free, flame retardant
*Remark: Other constructions available on
(SHF1, IEC 60092-359); all sheath and
request
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)
30

188
Opmaak Control Cables 27-07-2001 15:19 Pagina 25

General data for HXXM Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
number of number of nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1x2x1 7 1.3 3.1 0.350 8.9 45 57 85 5.6 18.5
2x2x1 7 1.3 3.1 0.567 14.4 86 202 300 5.6 18.5
4x2x1 7 1.3 3.1 0.673 17.1 103 296 440 5.6 18.5
7x2x1 7 1.3 3.1 0.748 19.0 114 336 500 5.6 18.5
10 x 2 x 1 7 1.3 3.1 0.984 25.0 150 504 750 5.6 18.5
12 x 2 x 1 7 1.3 3.1 1.047 26.6 160 571 850 5.6 18.5
16 x 2 x 1 7 1.3 3.1 1.185 30.1 181 739 1,100 5.6 18.5
19 x 2 x 1 7 1.3 3.1 1.209 30.7 184 806 1,200 5.6 18.5
1 x 2 x 1.5 7 1.6 3.4 0.371 9.4 57 67 100 3.7 12.3
2 x 2 x 1.5 7 1.6 3.4 0.606 15.4 92 235 350 3.7 12.3
5 x 2 x 1.5 7 1.6 3.4 0.799 20.3 122 363 540 3.7 12.3
12 x 2 x 1.5 7 1.6 3.4 1.130 28.7 172 659 980 3.7 12.3
12 x 2 x 2.5 7 2.0 3.8 1.272 32.3 194 853 1.270 2.30 7.56
2x2x4 7 2.5 4.6 0.787 20.0 120 356 530 1.43 4.70

1x3x1 7 1.3 3.1 0.369 9.4 47 67 100 5.6 18.5


1 x 3 x 1.5 7 1.6 3.4 0.392 10.0 50 87 130 3.7 12.3
10 x 3 x 1.5 7 1.6 3.4 1.240 31.5 189 806 1,200 3.7 12.3
16 x 3 x 1.5 7 1.6 3.4 1.449 36.8 221 1,062 1,580 3.7 12.3

Electrical characteristics for HXXM Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductance
conductor core to core (nF/M) core to core (nF/km) core to shield (nF/M) core to shield (nF/km) (mH/M) (mH/km)
(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad
1 19 63 33 108 0.22 0.72
1.5 21 70 37 121 0.21 0.68
2.5 24 79 41 136 0.20 0.64
4 25 82 43 142 0.19 0.62

189
Opmaak Control Cables 27-07-2001 15:19 Pagina 24

Instrumentation and communication cables


HXXM EEP 250 V IEC 60092-3
Individually shielded and isolated*

Application: Identification of the groups:

Unarmored, individually shielded and isolated instrumen- 1 pair black, white


tation and communication cables 250 V with special multi pairs black, white
properties for electrical installations in ships and offshore (groups sequential numbered
units. Temperature Class 85 C, Flame Retardant 1-1, 2-2, 3-3 etc.)
(IEC 60332-3 category A, A/F), Low Smoke, Halogen 1 triad black, white, red
Free, Low Toxicity. Suitable for application in cold climate multi triads black, white, red
areas required to pass cold bend and cold impact testing (groups sequential numbered
at 40 C and 35 C, respectively. 1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:


Construction:
Fire propagation: IEC 60332-3 category A, A/F
According to IEC 60092-3 with enhanced properties.
Smoke: IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
Conductors: stranded bare annealed
Acidity: IEC 60754-1/2 and MIL-C-24643A
copper, IEC 60228, sizes 1 - 4 mm2
(par. 4.7.25)
Insulation: cross linked polyethylene (XLPE/
Halogen content: IEC 60754-1/2 and MIL-C-24643A
HF XLPE) according to IEC 60092-3,
(par. 4.7.26)
IEC 60092-351 and IEEE Std 45
Toxicity index: NES 713
Twisting: cores twisted to a pair/triad
Cold properties: cold bend (40 C) and cold impact
Individual shield tinned copper drain wire; alumi-
(35 C) according to CAN/CSA-C22.2
and isolation: num/polyester tape; polyester tape
No. 0.3-Dec. 92
Assembly: shielded pairs/triads cabled together
Sheathing: halogen free, flame retardant
*Remark: Other constructions available on
(SHF1, IEC 60092-359); all sheath and
request
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)
24

190
Opmaak Control Cables 27-07-2001 15:19 Pagina 25

General data for HXXM Individually shielded and isolated EEP 250V IEC 60092-3
number of number of nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1x2x1 7 1.3 3.1 0.350 8.9 45 57 85 5.6 18.5
2x2x1 7 1.3 3.1 0.567 14.4 86 202 300 5.6 18.5
4x2x1 7 1.3 3.1 0.673 17.1 103 296 440 5.6 18.5
7x2x1 7 1.3 3.1 0.748 19.0 114 336 500 5.6 18.5
10 x 2 x 1 7 1.3 3.1 0.984 25.0 150 504 750 5.6 18.5
12 x 2 x 1 7 1.3 3.1 1.047 26.6 160 571 850 5.6 18.5
16 x 2 x 1 7 1.3 3.1 1.185 30.1 181 739 1,100 5.6 18.5
19 x 2 x 1 7 1.3 3.1 1.209 30.7 184 806 1,200 5.6 18.5
1 x 2 x 1.5 7 1.6 3.4 0.371 9.4 57 67 100 3.7 12.3
2 x 2 x 1.5 7 1.6 3.4 0.606 15.4 92 235 350 3.7 12.3
5 x 2 x 1.5 7 1.6 3.4 0.799 20.3 122 363 540 3.7 12.3
12 x 2 x 1.5 7 1.6 3.4 1.130 28.7 172 659 980 3.7 12.3
12 x 2 x 2.5 7 2.0 3.8 1.272 32.3 194 853 1.270 2.30 7.56
2x2x4 7 2.5 4.6 0.787 20.0 120 356 530 1.43 4.70

1x3x1 7 1.3 3.1 0.369 9.4 47 67 100 5.6 18.5


1 x 3 x 1.5 7 1.6 3.4 0.392 10.0 50 87 130 3.7 12.3
10 x 3 x 1.5 7 1.6 3.4 1.240 31.5 189 806 1,200 3.7 12.3
16 x 3 x 1.5 7 1.6 3.4 1.449 36.8 221 1,062 1,580 3.7 12.3

Electrical characteristics for HXXM Individually shielded and isolated EEP 250 V IEC 60092-3
cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductance
conductor core to core (nF/M) core to core (nF/km) core to shield (nF/M) core to shield (nF/km) (mH/M) (mH/km)
(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad
1 19 63 33 108 0.22 0.72
1.5 21 70 37 121 0.21 0.68
2.5 24 79 41 136 0.20 0.64
4 25 82 43 142 0.19 0.62

191
Opmaak Control Cables 27-07-2001 15:15 Pagina 12

Power and control cables


HXXMB EEP 0.6/1 kV IEC 60092-3
Class 5 conductors

Application: Identification of the cores:

Armored power and control cables 0.6/1 kV with special 1 core black
properties for electrical installations in ships and offshore 2 cores black, blue
units. Temperature Class 85 C, Flame Retardant (IEC 3 cores black, blue, brown
60332-3 category A, A/F), Low Smoke, Halogen Free, 4 cores black, blue, brown, green/yellow
Low Toxicity. Suitable for application in cold climate areas
required to pass cold bent and cold impact testing at
Special cable properties:
40 C and 35 C, respectively.
Fire propagation: IEC 60332-3 category A, A/F
Smoke: IEC 61034-1/2, MIL-C-24643A
Construction: (par. 4.7.27) and NES 711
Acidity: IEC 60754-1/2 and MIL-C-24643A
Generally according to IEC 60092-3 0.6/1 kV
(par. 4.7.25)
Halogen content: IEC 60754-1/2 and MIL-C-24643A
Conductors: flexible bare annealed
(par. 4.7.26)
copper, IEC 60228, (Class 5)
Toxicity index: NES 713
sizes 1 - 300 mm2
Cold properties: cold bend (40 C) and cold impact
Insulation: cross linked polyethylene (XLPE/
(35 C) according to CAN/CSA-C22.2
HF XLPE) according to IEC 60092-3,
No. 0.3-Dec. 92
IEC 60092-351 and IEEE Std 45
Assembly: cores cabled together
Filler: halogen free filling compound
Innersheath: halogen free, flame retardant
(SHF1, IEC 60092-359)
Braiding: bronze wire according to IEEE Std 45,
CDA 220, weight coverage 90% on
nominal diameter according to
IEC 60092-3, wire diameter
0.32 - 0.40 mm
Sheathing: halogen free, flame retardant (SHF1,
IEC 60092-359); all sheath and
12 jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

192
Opmaak Control Cables 27-07-2001 15:15 Pagina 13

General data for HXXMB EEP 0.6/1 kV IEC 60092-3


Class 5 conductors
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 5 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1 x 35 266 8.2 11.0 0.535 13.6 0.32 0.697 17.7 106 443 660 0.169 0.554
1 x 50 380 9.8 12.8 0.713 18.1 0.32 0.874 22.2 133 685 1,020 0.118 0.386
1 x 70 330 11.6 15.1 0.811 20.6 0.32 0.980 24.9 149 874 1,300 0.083 0.272
1 x 95 437 13.1 16.8 0.886 22.5 0.32 1.055 26.8 161 1,062 1,580 0.063 0.206
1 x 120 562 15.4 19.2 0.988 25.1 0.32 1.173 29.8 179 1,310 1,950 0.049 0.161
1 x 150 703 17.1 21.2 1.094 27.8 0.32 1.287 32.7 196 1,596 2,375 0.039 0.129
1 x 185 851 18.5 22.8 1.165 29.6 0.32 1.358 34.5 207 1,848 2,750 0.032 0.106
1 x 240 1,117 21.3 26.0 1.307 33.2 0.40 1.520 38.6 232 2,369 3,525 0.0244 0.0801
1 x 300 1,384 23.7 28.8 1.429 36.3 0.40 1.650 41.9 251 2,856 4,250 0.0195 0.0641
2x 35 266 8.2 11.0 1.067 27.1 0.32 1.260 32.0 192 1,270 1,890 0.169 0.554
2x 50 380 9.8 12.8 1.228 31.2 0.40 1.402 35.6 214 1,720 2,560 0.118 0.386
2x 70 330 11.6 15.1 1.437 36.5 0.40 1.657 42.1 253 2,301 3,425 0.083 0.272
2x 95 437 13.1 16.8 1.587 40.3 0.40 1.815 46.1 277 2,822 4,200 0.063 0.206
3 x 35 266 8.2 11.0 1.154 29.3 0.32 1.346 34.2 205 1,512 2,250 0.169 0.554
3 x 50 380 9.8 12.8 1.315 33.4 0.40 1.528 38.8 233 2,036 3,030 0.118 0.386
3 x 70 330 11.6 15.1 1.543 39.2 0.40 1.772 45.0 270 2,755 4,100 0.083 0.272
3 x 95 437 13.1 16.8 1.701 43.2 0.40 1.937 49.2 295 3,420 5,090 0.063 0.206
3 x 120 562 15.4 19.2 1.929 49.0 0.40 2.173 55.2 331 4,301 6,400 0.049 0.161
3 x 150 703 17.1 21.2 2.122 53.9 0.40 2.374 60.3 362 5,214 7,760 0.039 0.129
3 x 185 851 18.5 22.8 2.272 57.7 0.40 2.531 64.3 386 6,064 9,025 0.032 0.106
3 x 240 1,117 21.3 26.0 2.579 65.5 0.40 2.854 72.5 435 7,795 11,600 0.0244 0.0801
4 x 35 266 8.2 11.0 1.272 32.3 0.40 1.484 37.7 226 1,881 2,800 0.169 0.554
4 x 50 380 9.8 12.8 1.457 37.0 0.40 1.677 42.6 256 2,486 3,700 0.118 0.386
4 x 70 330 11.6 15.1 1.709 43.4 0.40 1.945 49.4 296 3,360 5,000 0.083 0.272
4 x 95 437 13.1 16.8 1.890 48.0 0.40 2.134 54.2 325 4,206 6,260 0.063 0.206
4 x 120 562 15.4 19.2 2.146 54.5 0.40 2.398 60.9 365 5,288 7,870 0.049 0.161
4 x 150 703 17.1 21.2 2.354 59.8 0.40 2.614 66.4 398 6,384 9,500 0.039 0.129

193
Opmaak Control Cables 27-07-2001 15:13 Pagina 6

Power and control cables


HXXMB-FR EEP 0.6/1 kV IEC 60092-3
Class 2 conductors

Application: Identification of the cores:

Armored fire resistant power and control cables 0.6/1 kV 1 core black
with special properties for electrical installations in ships 2 cores black, blue
and offshore units. Temperature Class 85 C, Flame 3 cores black, blue, brown
Retardant (IEC 60332-3 category A, A/F), Low Smoke, 4 cores black, blue, brown, green/yellow
Halogen Free, Low Toxicity and Fire Resistant 5 cores and up: black, numbered
(IEC 60331 950 C). Suitable for application in cold climate
areas required to pass cold bend and cold impact testing
Special cable properties:
at 40 C and 35 C, respectively.
Fire propagation: IEC 60332-3 category A, A/F
Fire resistance: IEC 60331 950 C
Construction: Smoke: IEC 61034-1/2 , MIL-C-24643A
(par. 4.7.27) and NES 711
Generally according to IEC 60092-3 0.6/1 kV
Acidity: IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
Conductors: stranded bare annealed
Halogen content: IEC 60754-1/2 and MIL-C-24643A
copper, IEC 60228, (Class 2)
(par. 4.7.26)
sizes 1 - 300 mm2
Toxicity index: NES 713
Insulation: mica tape, and cross linked polyethy-
Cold properties: cold bend (40 C) and cold impact
lene (XLPE/HF XLPE) according to
(35 C) according to CAN/CSA-C22.2
IEC 60092-3, IEC 60092-351 and IEEE
No. 0.3-Dec. 92
Std 45
Assembly: cores cabled together
Filler: halogen free filling compound
Innersheath: halogen free, flame retardant,
(SHF1, IEC 60092-359)
Braiding: bronze wires according to IEEE Std
45, CDA 220, weight coverage 90%
on nominal diameter, according to
IEC 60092-3, wire diameter
0.32 - 0.40 mm
6 Sheathing: halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 Ibs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

194
Opmaak Control Cables 27-07-2001 15:13 Pagina 7

General data for HXXMB-FR EEP 0.6/1 kV IEC 60092-3


Class 2 conductors
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1 x 1.5 7 1.6 4.3 0.252 6.4 0.32 0.394 10.0 50 111 165 3.7 12.1
1 x 2.5 7 2.0 4.7 0.272 6.9 0.32 0.413 10.5 53 121 180 2.26 7.41
1x 4 7 2.5 5.5 0.299 7.6 0.32 0.441 11.2 56 144 215 1.41 4.61
1x 6 7 3.1 6.0 0.319 8.1 0.32 0.461 11.7 59 161 240 0.94 3.08
1 x 10 7 4.0 7.1 0.370 9.4 0.32 0.516 13.1 79 212 315 0.56 1.83
1 x 16 7 5.0 8.3 0.421 10.7 0.32 0.575 14.6 88 276 410 0.35 1.15
1 x 25 7 6.3 9.8 0.492 12.5 0.32 0.646 16.4 98 363 540 0.222 0.727
1 x 35 19 7.0 10.6 0.520 13.2 0.32 0.681 17.3 104 437 650 0.160 0.524
1 x 50 19 8.1 11.9 0.677 17.2 0.32 0.839 21.3 128 645 960 0.118 0.387
1 x 70 19 9.7 13.9 0.764 19.4 0.32 0.933 23.7 142 840 1,250 0.082 0.268
1 x 95 19 11.4 15.8 0.846 21.5 0.32 1.016 25.8 155 1,055 1,570 0.059 0.193
1 x 120 37 13.9 18.6 0.961 24.4 0.32 1.146 29.1 175 1,290 1,920 0.047 0.153
1 x 150 37 15.5 20.3 1.059 26.9 0.32 1.252 31.8 191 1,546 2,300 0.038 0.124
1 x 185 37 17.3 22.3 1.150 29.2 0.32 1.343 34.1 205 1,848 2,750 0.0302 0.0991
1 x 240 61 19.9 25.4 1.283 32.6 0.40 1.496 38.0 228 2,385 3,550 0.0230 0.0754
1 x 300 61 22.2 28.1 1.398 35.5 0.40 1.618 41.1 247 2,856 4,250 0.0183 0.0601
2x 1.5 7 1.6 4.3 0.461 11.7 0.32 0.614 15.6 94 255 380 3.7 12.1
2x 2.5 7 2.0 4.7 0.508 12.9 0.32 0.661 16.8 101 302 450 2.26 7.41
2x 4 7 2.5 5.5 0.579 14.7 0.32 0.740 18.8 113 383 570 1.41 4.61
2x 6 7 3.1 6.0 0.630 16.0 0.32 0.791 20.1 121 450 670 0.94 3.08
2x 10 7 4.0 7.1 0.728 18.5 0.32 0.890 22.6 136 591 880 0.56 1.83
2x 16 7 5.0 8.3 0.850 21.6 0.32 1.020 25.9 155 806 1,200 0.35 1.15
2x 25 7 6.3 9.8 0.976 24.8 0.32 1.161 29.5 177 1,075 1,600 0.222 0.727
2x 35 19 7.0 10.6 1.035 26.3 0.32 1.228 31.2 187 1,243 1,850 0.160 0.524
2x 50 19 8.1 11.9 1.157 29.4 0.40 1.370 34.8 209 1,646 2,450 0.118 0.387
2x 70 19 9.7 13.9 1.346 34.2 0.40 1.567 39.8 239 2,184 3,250 0.082 0.268
2x 95 19 11.4 15.8 1.512 38.4 0.40 1.740 44.2 265 2,755 4,100 0.059 0.193
3 x 1.5 7 1.6 4.3 0.492 12.5 0.32 0.646 16.4 98 282 420 3.7 12.1
3 x 2.5 7 2.0 4.7 0.535 13.6 0.32 0.689 17.5 105 329 490 2.26 7.41
3x 4 7 2.5 5.5 0.614 15.6 0.32 0.776 19.7 118 417 620 1.41 4.61
3x 6 7 3.1 6.0 0.669 17.0 0.32 0.831 21.1 127 497 740 0.94 3.08
3 x 10 7 4.0 7.1 0.772 19.6 0.32 0.941 23.9 143 672 1,000 0.56 1.83
3 x 16 7 5.0 8.3 0.886 22.5 0.32 1.063 27.0 162 874 1,300 0.35 1.15
3 x 25 7 6.3 9.8 1.039 26.4 0.32 1.224 31.1 187 1,210 1,800 0.222 0.727
3 x 35 19 7.0 10.6 1.110 28.2 0.32 1.303 33.1 199 1,478 2,200 0.160 0.524
3 x 50 19 8.1 11.9 1.240 31.5 0.40 1.453 36.9 221 1,949 2,900 0.118 0.387
3 x 70 19 9.7 13.9 1.425 36.2 0.40 1.654 42.0 252 2,587 3,850 0.082 0.268
3 x 95 19 11.4 15.8 1.618 41.1 0.40 1.854 47.1 283 3,360 5,000 0.059 0.193
3 x 120 37 13.9 18.6 1.862 47.3 0.40 2.106 53.5 321 4,133 6,150 0.047 0.153
3 x 150 37 15.5 20.3 2.047 52.0 0.40 2.299 58.4 350 5,006 7,450 0.038 0.124
3 x 185 37 17.3 22.3 2.236 56.8 0.40 2.496 63.4 380 6,048 9,000 0.0302 0.0991
3 x 240 61 19.9 25.4 2.524 64.1 0.40 2.799 71.1 427 7,728 11,500 0.0230 0.0754
4 x 1.5 7 1.6 4.3 0.543 13.8 0.32 0.697 17.7 106 323 480 3.7 12.1
4 x 2.5 7 2.0 4.7 0.583 14.8 0.32 0.744 18.9 113 376 560 2.26 7.41
4x 4 7 2.5 5.5 0.661 16.8 0.32 0.823 20.9 125 470 700 1.41 4.61
4x 6 7 3.1 6.0 0.713 18.1 0.32 0.874 22.2 133 558 830 0.94 3.08
4 x 10 7 4.0 7.1 0.854 21.7 0.32 1.024 26.0 156 806 1,200 0.56 1.83
4 x 16 7 5.0 8.3 0.980 24.9 0.32 1.165 29.6 178 1,075 1,600 0.35 1.15
4 x 25 7 6.3 9.8 1.142 29.0 0.32 1.335 33.9 203 1,478 2,200 0.222 0.727
4 x 35 19 7.0 10.6 1.236 31.4 0.40 1.449 36.8 221 1,881 2,800 0.160 0.524
4 x 50 19 8.1 11.9 1.366 34.7 0.40 1.587 40.3 242 2,385 3,550 0.118 0.387
4 x 70 19 9.7 13.9 1.583 40.2 0.40 1.819 46.2 277 3,192 4,750 0.082 0.268
4 x 95 19 11.4 15.8 1.799 45.7 0.40 2.043 51.9 311 4,166 6,200 0.059 0.193
4 x 120 37 13.9 18.6 2.071 52.6 0.40 2.323 59.0 354 5,107 7,600 0.047 0.153
4 x 150 37 15.5 20.3 2.272 57.7 0.40 2.531 64.3 386 6,182 9,200 0.038 0.124
5x 1.5 7 1.6 4.3 0.602 15.3 0.32 0.764 19.4 116 376 560 3.7 12.1
5x 2.5 7 2.0 4.7 0.650 16.5 0.32 0.811 20.6 124 437 650 2.26 7.41
5x 4 7 2.5 5.5 0.736 18.7 0.32 0.906 23.0 138 571 850 1.41 4.61
24 x 1 7 1.3 3.8 1.047 26.6 0.32 1.228 31.2 187 806 1,200 5.5 18.1
6x 1.5 7 1.6 4.3 0.622 15.8 0.32 0.783 19.9 119 349 520 3.7 12.1
7x 1.5 7 1.6 4.3 0.626 15.9 0.32 0.787 20.0 120 373 555 3.7 12.1
8x 1.5 7 1.6 4.3 0.681 17.3 0.32 0.843 21.4 128 400 595 3.7 12.1
12 x 1.5 7 1.6 4.3 0.827 21.0 0.32 0.996 25.3 152 548 815 3.7 12.1
20 x 1.5 7 1.6 4.3 1.043 26.5 0.32 1.228 31.2 187 796 1,185 3.7 12.1
24 x 1.5 7 1.6 4.3 1.169 29.7 0.32 1.362 34.6 208 1,008 1,500 3.7 12.1
30 x 1.5 7 1.6 4.3 1.248 31.7 0.40 1.461 37.1 223 1,162 1,730 3.7 12.1
37 x 1.5 7 1.6 4.3 1.358 34.5 0.40 1.571 39.9 239 1,378 2,050 3.7 12.1
6x 2.5 7 2.0 4.7 0.673 17.1 0.32 0.835 21.2 127 403 600 2.26 7.41
7x 2.5 7 2.0 4.7 0.677 17.2 0.32 0.839 21.3 128 430 640 2.26 7.41
8x 2.5 7 2.0 4.7 0.744 18.9 0.32 0.913 23.2 139 497 740 2.26 7.41
10 x 2.5 7 2.0 4.7 0.874 195
22.2 0.32 1.043 26.5 159 598 890 2.26 7.41
12 x 2.5 7 2.0 4.7 0.906 23.0 0.32 1.083 27.5 165 672 1,000 2.26 7.41
Opmaak Control Cables 27-07-2001 15:14 Pagina 8

Power and control cables


HXXMB-FR EEP 0.6/1 kV IEC 60092-3
Class 5 conductors

Application: Identification of the cores:

Armored fire resistant power and control cables 0.6/1 kV 1 core black
with special properties for electrical installations in ships 2 cores black, blue
and offshore units. Temperature Class 85 C, Flame 3 cores black, blue, brown
Retardant (IEC 60332-3 category A, A/F), Low Smoke, 4 cores black, blue, brown, green/yellow
Halogen Free, Low Toxicity and Fire Resistant
(IEC 60331 950 C). Suitable for application in cold climate
Special cable properties:
areas required to pass cold bend and cold impact testing
at 40 C and 35 C, respectively. Fire propagation: IEC 60332-3 category A, A/F
Fire resistance: IEC 60331 950 C
Smoke: IEC 61034-1/2 , MIL-C-24643A
Construction: (par. 4.7.27) and NES 711
Acidity: IEC 60754-1/2 and MIL-C-24643A
Generally according to IEC 60092-3 0.6/1 kV
(par. 4.7.25)
Halogen content: IEC 60754-1/2 and MIL-C-24643A
Conductors: flexible bare annealed
(par. 4.7.26)
copper, IEC 60228, (Class 5)
Toxicity index: NES 713
sizes 1 - 300 mm2
Cold properties: cold bend (40 C) and cold impact
Insulation: mica tape, and cross linked polyethy-
(35 C) according to CAN/CSA-C22.2
lene (XLPE/HF XLPE) according to
No. 0.3-Dec. 92
IEC 60092-3, IEC 60092-351 and IEEE
Std 45
Assembly: cores cabled together
Filler: halogen free filling compound
Innersheath: halogen free, flame retardant,
(SHF1, IEC 60092-359)
Braiding: bronze wires according to IEEE Std
45, CDA 220, weight coverage 90%
on nominal diameter, according to
IEC 60092-3, wire diameter
0.32 - 0.40 mm
8 Sheathing: halogen free, flame retardant (SHF1,
IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

196
Opmaak Control Cables 27-07-2001 15:14 Pagina 9

General data for HXXMB-FR EEP 0.6/1 kV IEC 60092-3


Class 5 conductors
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 5 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1 x 35 266 8.2 11.7 0.563 14.3 0.32 0.724 18.4 110 454 675 0.169 0.554
1 x 50 380 9.8 13.5 0.740 18.8 0.32 0.902 22.9 137 706 1,050 0.118 0.386
1 x 70 330 11.6 15.8 0.839 21.3 0.32 1.008 25.6 154 907 1,350 0.083 0.272
1 x 95 437 13.1 17.5 0.913 23.2 0.32 1.083 27.5 165 1,075 1,600 0.063 0.206
1 x 120 562 15.4 20.0 1.020 25.9 0.32 1.205 30.6 184 1,337 1,990 0.049 0.161
1 x 150 703 17.1 21.9 1.122 28.5 0.32 1.315 33.4 200 1,629 2,425 0.039 0.129
1 x 185 851 18.5 23.5 1.193 30.3 0.32 1.386 35.2 211 1,868 2,780 0.032 0.106
1 x 240 1,117 21.3 26.8 1.339 34.0 0.40 1.551 39.4 236 2,396 3,565 0.0244 0.0801
1 x 300 1,384 23.7 29.6 1.457 37.0 0.40 1.677 42.6 256 2,856 4,250 0.0195 0.0641
2x 35 266 8.2 11.7 1.134 28.8 0.32 1.327 33.7 202 1,361 2,025 0.169 0.554
2x 50 380 9.8 13.5 1.303 33.1 0.40 1.516 38.5 231 1,831 2,725 0.118 0.386
2x 70 330 11.6 15.8 1.496 38.0 0.40 1.717 43.6 262 2,385 3,550 0.083 0.272
2x 95 437 13.1 17.5 1.646 41.8 0.40 1.874 47.6 286 2,940 4,375 0.063 0.206
3 x 35 266 8.2 11.7 1.217 30.9 0.32 1.409 35.8 215 1,593 2,370 0.169 0.554
3 x 50 380 9.8 13.5 1.378 35.0 0.40 1.591 40.4 242 2,150 3,200 0.118 0.386
3 x 70 330 11.6 15.8 1.602 40.7 0.40 1.831 46.5 279 2,873 4,275 0.083 0.272
3 x 95 437 13.1 17.5 1.764 44.8 0.40 2.000 50.8 305 3,528 5,250 0.063 0.206
3 x 120 562 15.4 20.0 2.000 50.8 0.40 2.244 57.0 342 4,421 6,580 0.049 0.161
3 x 150 703 17.1 21.9 2.185 55.5 0.40 2.437 61.9 371 5,342 7,950 0.039 0.129
3 x 185 851 18.5 23.5 2.350 59.7 0.40 2.610 66.3 398 6,249 9,300 0.032 0.106
3 x 240 1,117 21.3 26.8 2.642 67.1 0.40 2.917 74.1 445 7,929 11,800 0.0244 0.0801
4 x 35 266 8.2 11.7 1.346 34.2 0.40 1.559 39.6 238 1,982 2,950 0.169 0.554
4 x 50 380 9.8 13.5 1.524 38.7 0.40 1.744 44.3 266 2,570 3,825 0.118 0.386
4 x 70 330 11.6 15.8 1.780 45.2 0.40 2.016 51.2 307 3,467 5,160 0.083 0.272
4 x 95 437 13.1 17.5 1.961 49.8 0.40 2.205 56.0 336 4,314 6,240 0.063 0.206
4 x 120 562 15.4 20.0 2.224 56.5 0.40 2.476 62.9 377 5,443 8,100 0.049 0.161
4 x 150 703 17.1 21.9 2.425 61.6 0.40 2.685 68.2 409 6,552 9,750 0.039 0.129

197
Opmaak Control Cables 27-07-2001 15:17 Pagina 18

Instrumentation and communication cables


HXXMB-FR EEP 0.6/1 kV IEC 60092-3
Overall shielded*

Application: Identification of the groups:

Armored overall shielded fire resistant instrumentation 1 pair black, white


and communication cables 0.6/1 kV with special properties 1 triad black, white, red
for electrical installations in ships and offshore units. 1 quad black, white, red, green
Temperature Class 85 C, Flame Retardant (IEC 60332-3
category A, A/F), Low Smoke, Halogen Free, Low Special cable properties:
Toxicity and Fire Resistant (IEC 60331 950 C). Suitable for
Fire propagation: IEC 60332-3 category A, A/F
application in cold climate areas required to pass cold
Fire resistance: IEC 60331 950 C
bend and cold impact testing at 40 C and 35 C,
Smoke: IEC 61034-1/2, MIL-C-24643A
respectively.
(par. 4.7.27) and NES 711
Acidity: IEC 60754-1/2 and MIL-C-24643A
(par. 4.7.25)
Construction:
Halogen content: IEC 60754-1/2 and MIL-C-24643A
According to IEC 60092-3 with enhanced properties. (par. 4.7.26)
Toxicity index: NES 713
Conductors: stranded bare annealed Cold properties: cold bend (40 C) and cold impact
copper, IEC 60 228, sizes 1 to 2.5 mm2 (35 C) according to CAN/CSA-C22.2
Insulation: mica tape, and cross linked polyethy- No. 0.3-Dec. 92
lene (XLPE/HF XLPE) according to
IEC 60092-3, IEC 60092-351 and *Remark: Other constructions available on
IEEE Std 45 request.
Twisting: cores twisted to a pair/triad/quad
Overall shield: tinned copper drain wire; alumi-
num/polyester tape; polyester tape
Innersheath: halogen free, flame retardant
(SHF1, IEC 60092-359)
Braiding: bronze wires according to IEEE
Std 45, CDA 220, weight coverage
90% on nominal diameter according
to IEC 60092-3, wire diameter
18 0.32 - 0.40 mm
Sheathing: halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

198
Opmaak Control Cables 27-07-2001 15:17 Pagina 19

General data for HXXMB-FR Overall shielded EEP 0.6/1 kV IEC 60092-3
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1x2x1 7 1.3 3.8 0.406 10.3 0.32 0.559 14.2 85 195 290 5.6 18.5
1x3x1 7 1.3 3.8 0.429 10.9 0.32 0.583 14.8 89 215 320 5.6 18.5
1 x 2 x 1.5 7 1.6 4.1 0.429 10.9 0.32 0.579 14.7 88 208 310 3.7 12.3
1 x 3 x 1.5 7 1.6 4.1 0.461 11.7 0.32 0.614 15.6 94 249 370 3.7 12.3
1 x 4 x 1.5 7 1.6 4.1 0.504 12.8 0.32 0.665 16.9 101 280 416 3.7 12.3
1 x 2 x 2.5 7 2.0 4.5 0.472 12.0 0.32 0.622 15.8 95 269 400 2.30 7.56

Electrical characteristics for HXXMB-FR Overall shielded EEP 0.6/1 kV IEC 60092-3
,
cross section of mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductance loop inductance loop inductance
the conductor core to core (nF/M) core to core (nF/km) core to shield (nF/M) core to shield (nF/km) (mH/M) (mH/km) (mH/M) mH/km)
(mm2) pair, triad & quad pair, triad & quad pair, triad & quad pair, triad & quad pair & triad pair & triad quad quad
1 20 66 35 115 0.24 0.80 - -
1.5 22 73 38 124 0.23 0.76 0.27 0.90
2.5 25 82 42 138 0.21 0.70 - -

199
Opmaak Control Cables 27-07-2001 15:18 Pagina 22

Instrumentation and communication cables


HXXMB EEP 0.6/1 kV IEC 60092-3
Individually shielded and isolated*

Application: Identification of the groups:

Armored, individually shielded and isolated instrumen- 1 pair black, white


tation and communication cables 0.6/1 kV with special multi pairs black, white
properties for electrical installations in ships and offshore (groups sequential cores numbered
units. Temperature Class 85 C, Flame Retardant 1-1, 2-2, 3-3 etc.)
(IEC 60332-3 category A, A/F), Low Smoke, Halogen 1 triad black, white, red
Free, Low Toxicity. Suitable for application in cold climate multi triads black, white, red
areas required to pass cold bend and cold impact testing (groups sequential cores numbered
at 40 C and 35 C, respectively. 1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:


Construction:
Fire propagation: IEC 60332-3 category A, A/F
According to IEC 60092-3 with enhanced properties. Smoke: IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
Conductors: stranded bare annealed Acidity: IEC 60754-1/2 and MIL-C-24643A
copper, IEC 60228, sizes 1 - 4 mm2 (par. 4.7.25)
Insulation: cross linked polyethylene (XLPE/ Halogen content: IEC 60754-1/2 and MIL-C-24643A
HF XLPE) according to IEC 60092-3, (par. 4.7.26)
IEC 60092-351 and IEEE Std 45 Toxicity index: NES 713
Twisting: cores twisted to a pair/triad Cold properties: cold bend (40 C) and cold impact
Individual shield tinned copper drain wire; alumi- (35 C) according to CAN/CSA-C22.2
and isolation: num/polyester tape; polyester tape No. 0.3-Dec. 92
Assembly: shielded pairs/triads cabled together
Innersheath: halogen free, flame retardant *Remark: Other constructions available on
(SHF1, IEC 60092-359) request
Braiding: bronze wires according to IEEE
Std 45, CDA 220, weight coverage
90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
28 Sheathing: halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

200
Opmaak Control Cables 27-07-2001 15:18 Pagina 23

General data for HXXMB Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1x2x1 7 1.3 3.1 0.350 8.9 0.32 0.500 12.7 76 161 240 5.6 18.5
2x2x1 7 1.3 3.1 0.567 14.4 0.32 0.728 18.5 111 323 480 5.6 18.5
4x2x1 7 1.3 3.1 0.673 17.1 0.32 0.843 21.4 128 383 570 5.6 18.5
10 x 2 x 1 7 1.3 3.1 0.984 25.0 0.32 1.177 29.9 179 766 1,140 5.6 18.5
12 x 2 x 1 7 1.3 3.1 1.047 26.6 0.32 1.240 31.5 189 806 1,200 5.6 18.5
16 x 2 x 1 7 1.3 3.1 1.185 30.1 0.32 1.386 35.2 211 1,008 1,500 5.6 18.5
1 x 2 x 1.5 7 1.6 3.4 0.370 9.4 0.32 0.524 13.3 80 148 220 3.7 12.3
2 x 2 x 1.5 7 1.6 3.4 0.606 15.4 0.32 0.768 19.5 117 363 540 3.7 12.3
5 x 2 x 1.5 7 1.6 3.4 0.799 20.3 0.32 0.969 25.7 148 484 720 3.7 12.3
12 x 2 x 1.5 7 1.6 3.4 1.130 28.7 0.32 1.331 33.8 203 927 1,380 3.7 12.3
12 x 2 x 2.5 7 2.0 3.8 1.272 32.3 0.40 1.484 37.7 226 1,075 1,600 2.30 7.56
2x2x4 7 2.5 4.6 0.787 20.0 0.32 0.957 24.3 146 491 730 1.43 4.70

1x3x1 7 1.3 3.1 0.370 9.4 0.32 0.524 13.3 80 343 510 5.6 18.5
1 x 3 x 1.5 7 1.6 3.4 0.394 10.0 0.32 0.543 13.8 83 349 520 3.7 12.3
10 x 3 x 1.5 7 1.6 3.4 1.240 31.5 0.40 1.453 36.9 221 1,062 1,580 3.7 12.3
16 x 3 x 1.5 7 1.6 3.4 1.499 36.8 0.40 1.677 42.6 256 1,378 2,050 3.7 12.3

Electrical characteristics for HXXMB Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductance
conductor core to core (nF/M) core to core (nF/km) core to shield (nF/M) core to shield (nF/km) (mH/M) (mH/km)
(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad
1 19 63 33 108 0.22 0.72
1.5 21 70 37 121 0.21 0.68
2.5 24 79 41 136 0.20 0.64
4 25 82 43 142 0.19 0.62

201
Opmaak Control Cables 27-07-2001 15:18 Pagina 22

Instrumentation and communication cables


HXXMB EEP 250 V IEC 60092-3
Individually shielded and isolated*

Application: Identification of the groups:

Armored, individually shielded and isolated instrumen- 1 pair black, white


tation and communication cables 250 V with special multi pairs black, white
properties for electrical installations in ships and offshore (groups sequential cores numbered
units. Temperature Class 85 C, Flame Retardant 1-1, 2-2, 3-3 etc.)
(IEC 60332-3 category A, A/F), Low Smoke, Halogen 1 triad black, white, red
Free, Low Toxicity. Suitable for application in cold climate multi triads black, white, red
areas required to pass cold bend and cold impact testing (groups sequential cores numbered
at 40 C and 35 C, respectively. 1-1-1, 2-2-2, 3-3-3, etc.)

Special cable properties:


Construction:
Fire propagation: IEC 60332-3 category A, A/F
According to IEC 60092-3 with enhanced properties. Smoke: IEC 61034-1/2, MIL-C-24643A
(par. 4.7.27) and NES 711
Conductors: stranded bare annealed Acidity: IEC 60754-1/2 and MIL-C-24643A
copper, IEC 60228, sizes 1 - 4 mm2 (par. 4.7.25)
Insulation: cross linked polyethylene (XLPE/ Halogen content: IEC 60754-1/2 and MIL-C-24643A
HF XLPE) according to IEC 60092-3, (par. 4.7.26)
IEC 60092-351 and IEEE Std 45 Toxicity index: NES 713
Twisting: cores twisted to a pair/triad Cold properties: cold bend (40 C) and cold impact
Individual shield tinned copper drain wire; alumi- (35 C) according to CAN/CSA-C22.2
and isolation: num/polyester tape; polyester tape No. 0.3-Dec. 92
Assembly: shielded pairs/triads cabled together
Innersheath: halogen free, flame retardant *Remark: Other constructions available on
(SHF1, IEC 60092-359) request
Braiding: bronze wires according to IEEE
Std 45, CDA 220, weight coverage
90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
22 Sheathing: halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

202
Opmaak Control Cables 27-07-2001 15:18 Pagina 23

General data for HXXMB Individually shielded and isolated EEP 250V IEC 60092-3
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1x2x1 7 1.3 3.1 0.350 8.9 0.32 0.500 12.7 76 161 240 5.6 18.5
2x2x1 7 1.3 3.1 0.567 14.4 0.32 0.728 18.5 111 323 480 5.6 18.5
4x2x1 7 1.3 3.1 0.673 17.1 0.32 0.843 21.4 128 383 570 5.6 18.5
10 x 2 x 1 7 1.3 3.1 0.984 25.0 0.32 1.177 29.9 179 766 1,140 5.6 18.5
12 x 2 x 1 7 1.3 3.1 1.047 26.6 0.32 1.240 31.5 189 806 1,200 5.6 18.5
16 x 2 x 1 7 1.3 3.1 1.185 30.1 0.32 1.386 35.2 211 1,008 1,500 5.6 18.5
1 x 2 x 1.5 7 1.6 3.4 0.370 9.4 0.32 0.524 13.3 80 148 220 3.7 12.3
2 x 2 x 1.5 7 1.6 3.4 0.606 15.4 0.32 0.768 19.5 117 363 540 3.7 12.3
5 x 2 x 1.5 7 1.6 3.4 0.799 20.3 0.32 0.969 24.6 148 484 720 3.7 12.3
12 x 2 x 1.5 7 1.6 3.4 1.130 28.7 0.32 1.331 33.8 203 927 1,380 3.7 12.3
12 x 2 x 2.5 7 2.0 3.8 1.272 32.3 0.40 1.484 37.7 226 1,075 1,600 2.30 7.56
2x2x4 7 2.5 4.6 0.787 20.0 0.32 0.957 24.3 146 491 730 1.43 4.70

1x3x1 7 1.3 3.1 0.370 9.4 0.32 0.524 13.3 80 343 510 5.6 18.5
1 x 3 x 1.5 7 1.6 3.4 0.394 10.0 0.32 0.543 13.8 83 349 520 3.7 12.3
10 x 3 x 1.5 7 1.6 3.4 1.240 31.5 0.40 1.453 36.9 221 1,062 1,580 3.7 12.3
16 x 3 x 1.5 7 1.6 3.4 1.499 36.8 0.40 1.677 42.6 256 1,378 2,050 3.7 12.3

Electrical characteristics for HXXMB Individually shielded and isolated EEP 250 V IEC 60092-3
cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductance
conductor core to core (nF/M) core to core (nF/km) core to shield (nF/M) core to shield (nF/km) (mH/M) (mH/km)
(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad
1 19 63 33 108 0.22 0.72
1.5 21 70 37 121 0.21 0.68
2.5 24 79 41 136 0.20 0.64
4 25 82 43 142 0.19 0.62

203
Opmaak Control Cables 27-07-2001 15:18 Pagina 20

Instrumentation and communication cables


HXXMB-FR EEP 0.6/1 kV IEC 60092-3
Individually shielded and isolated*

Application: Identification of the groups:

Armored, individually shielded and isolated fire resistant 1 pair black, white
instrumentation and communication cables 0.6/1 kV with multi pairs black, white
special properties for electrical installations in ships and (groups sequential numbered
offshore units. Temperature Class 85 C, Flame Retardant 1-1, 2-2, 3-3 etc.)
(IEC 60332-3 category A/F), Low Smoke, Halogen Free, 1 triad black, white, red
Low Toxicity and Fire Resistant (IEC 60331 950 C). Suitable multi triads black, white, red
for application in cold climate areas required to pass cold (groups sequential numbered
bend and cold impact testing at 40 C and 35 C, 1-1-1, 2-2-2, 3-3-3 etc.)
respectively.

Special cable properties:


Construction:
Fire propagation: IEC 60332-3 category A, A/F
According to IEC 60092-3 with enhanced properties. Fire resistance: IEC 60331 950 C
Smoke: IEC 61034-1/2, MIL-C-24643A (par. 4.7.27) and
Conductors: stranded bare annealed NES 711
copper, IEC 60228, sizes 1 to 4 mm2 Acidity: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.25)
Insulation: mica tape, and cross linked polyethy- Halogen content: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.26)
lene (XLPE/HF XLPE) according to Toxicity index: NES 713
IEC 60092-3, IEC 60092-351 and Cold properties: cold bend (40 C) and cold impact (35 C)
IEEE Std 45 according to CAN/CSA-C22.2 No. 0.3-Dec. 92
Twisting: cores twisted to a pair/triad/quad
Individual shield tinned copper drain wire; alumi- *Remark: Other constructions available on request
and isolation: num/polyester tape; polyester tape
Assembly: shielded pairs/triads/quads cabled
together
Innersheath: halogen free, flame retardant
(SHF1, IEC 60092-359)
Braiding: bronze wires according to IEEE
Std 45, CDA 220, weight coverage
26 90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
Sheathing: halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

204
Opmaak Control Cables 27-07-2001 15:18 Pagina 21

General data for HXXMB-FR Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1x2x1 7 1.3 3.8 0.406 10.3 0.32 0.559 14.2 85 195 290 5.6 18.5
2x2x1 7 1.3 3.8 0.677 17.2 0.32 0.846 21.5 129 390 580 5.6 18.5
4x2x1 7 1.3 3.8 0.799 20.3 0.32 0.969 24.6 148 484 720 5.6 18.5
7x2x1 7 1.3 3.8 0.909 23.1 0.32 1.087 27.6 166 625 930 5.6 18.5
8x2x1 7 1.3 3.8 1.004 25.5 0.32 1.189 30.2 181 739 1,100 5.6 18.5
10 x 2 x 1 7 1.3 3.8 1.177 29.9 0.40 1.390 35.3 212 1,008 1,500 5.6 18.5
12 x 2 x 1 7 1.3 3.8 1.264 32.1 0.40 1.476 37.5 225 1,075 1,600 5.6 18.5
16 x 2 x 1 7 1.3 3.8 1.429 36.3 0.40 1.650 41.9 251 1,344 2,000 5.6 18.5
19 x 3 x 1 7 1.3 3.8 1.465 37.2 0.40 1.693 43.0 258 1,411 2,100 5.6 18.5
1 x 2 x 1.5 7 1.6 4.1 0.429 10.9 0.32 0.579 14.7 88 208 310 3.7 12.3
2 x 2 x 1.5 7 1.6 4.1 0.717 18.2 0.32 0.882 22.4 134 423 630 3.7 12.3
4 x 2 x 1.5 7 1.6 4.1 0.846 21.5 0.32 1.024 26.0 156 551 820 3.7 12.3
5 x 2 x 1.5 7 1.6 4.1 0.945 24.0 0.32 1.122 28.5 171 645 960 3.7 12.3
8 x 2 x 1.5 7 1.6 4.1 1.063 27.0 0.32 1.248 31.7 190 796 1,185 3.7 12.3
12 x 2 x 1.5 7 1.6 4.1 1.350 34.3 0.40 1.571 39.9 239 1,243 1,850 3.7 12.3
1 x 2 x 2.5 7 2.0 4.5 0.472 12.0 0.32 0.622 15.8 95 269 400 2.30 7.56
12 x 2 x 2.5 7 2.0 4.5 1.480 37.6 0.40 1.709 43.4 260 1,411 2,100 2.30 7.56
2x2x4 7 2.5 5.3 0.898 22.8 0.32 1.075 27.3 164 605 900 1.43 4.70

1x3x1 7 1.3 3.8 0.429 10.9 0.32 0.583 14.8 89 215 320 5.6 18.5
4x3x1 7 1.3 3.8 0.909 23.1 0.32 1.087 27.6 166 591 880 5.6 18.5
1 x 3 x 1.5 7 1.6 4.1 0.461 11.7 0.32 0.614 15.6 94 249 370 3.7 12.3
10 x 3 x 1.5 7 1.6 4.1 1.469 37.3 0.40 1.697 43.1 259 1,478 2,200 3.7 12.3
16 x 3 x 1.5 7 1.6 4.1 1.819 46.2 0.40 2.063 52.4 314 1,781 2,650 3.7 12.3

Electrical characteristics for HXXMB-FR Individually shielded and isolated EEP 0.6/1 kV IEC 60092-3
cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductance
conductor core to core (nF/M) core to core (nF/km) core to shield (nF/M) core to shield (nF/km) (mH/M) (mH/km)
(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad
1 20 66 35 115 0.24 0.80
1.5 22 73 38 124 0.23 0.76
2.5 25 82 42 138 0.21 0.70
4 26 84 43 141 0.21 0.68

205
Opmaak Control Cables 27-07-2001 15:18 Pagina 20

Instrumentation and communication cables


HXXMB-FR EEP 250 V IEC 60092-3
Individually shielded and isolated*

Application: Identification of the groups:

Armored, individually shielded and isolated fire resistant 1 pair black, white
instrumentation and communication cables 250 V with multi pairs black, white
special properties for electrical installations in ships and (groups sequential numbered
offshore units. Temperature Class 85 C, Flame Retardant 1-1, 2-2, 3-3 etc.)
(IEC 60332-3 category A/F), Low Smoke, Halogen Free, 1 triad black, white, red
Low Toxicity and Fire Resistant (IEC 60331 950 C). Suitable multi triads black, white, red
for application in cold climate areas required to pass cold (groups sequential numbered
bend and cold impact testing at 40 C and 35 C, 1-1-1, 2-2-2, 3-3-3 etc.)
respectively. 1 quad black, white, red, green

Special cable properties:


Construction:
Fire propagation: IEC 60332-3 category A, A/F
According to IEC 60092-3 with enhanced properties. Fire resistance: IEC 60331 950 C
Smoke: IEC 61034-1/2, MIL-C-24643A (par. 4.7.27) and
Conductors: stranded bare annealed NES 711
copper, IEC 60228, sizes 1 to 4 mm2 Acidity: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.25)
Insulation: mica tape, and cross linked polyethy- Halogen content: IEC 60754-1/2 and MIL-C-24643A (par. 4.7.26)
lene (XLPE/HF XLPE) according to Toxicity index: NES 713
IEC 60092-3, IEC 60092-351 and Cold properties: cold bend (40 C) and cold impact (35 C)
IEEE Std 45 according to CAN/CSA-C22.2 No. 0.3-Dec. 92
Twisting: cores twisted to a pair/triad/quad
Individual shield tinned copper drain wire; alumi- *Remark: Other constructions available on request
and isolation: num/polyester tape; polyester tape
Assembly: shielded pairs/triads/quads cabled
together
Innersheath: halogen free, flame retardant
(SHF1, IEC 60092-359)
Braiding: bronze wires according to IEEE
Std 45, CDA 220, weight coverage
20 90% on nominal diameter according
to IEC 60092-3, wire diameter
0.32 - 0.40 mm
Sheathing: halogen free, flame retardant
(SHF1, IEC 60092-359); all sheath and
jacketing materials shall pass tear
resistance testing to 35 lbs/in
(6.4 N/mm)
Sheathing color: gray (other colors are available on
request)

206
Opmaak Control Cables 27-07-2001 15:18 Pagina 21

General data for HXXMB-FR Individually shielded and isolated EEP 250 V IEC 60092-3
number of number of nominal nominal nominal nominal nominal nominal nominal minimum approxi- approxi- conductor conductor
cores and wires in conductor core diameter diameter diameter outer outer bending mate mate resistance resistance
nominal cross conductor diameter diameter over inner- over inner- of braiding diameter diameter radius weight weight at 20 C DC at 20 C DC
sectional area class 2 sheath sheath wire
(n x mm2) (n) (mm) (mm) (inches) (mm) (mm) (inches) (mm) (mm) (lbs/M) (kg/km) (/M) (/km)
1x2x1 7 1.3 3.8 0.406 10.3 0.32 0.559 14.2 85 195 290 5.6 18.5
2x2x1 7 1.3 3.8 0.677 17.2 0.32 0.846 21.5 129 390 580 5.6 18.5
4x2x1 7 1.3 3.8 0.799 20.3 0.32 0.969 24.6 148 484 720 5.6 18.5
7x2x1 7 1.3 3.8 0.909 23.1 0.32 1.087 27.6 166 625 930 5.6 18.5
8x2x1 7 1.3 3.8 1.004 25.5 0.32 1.189 30.2 181 739 1,100 5.6 18.5
10 x 2 x 1 7 1.3 3.8 1.177 29.9 0.40 1.390 35.3 212 1,008 1,500 5.6 18.5
12 x 2 x 1 7 1.3 3.8 1.264 32.1 0.40 1.476 37.5 225 1,075 1,600 5.6 18.5
16 x 2 x 1 7 1.3 3.8 1.429 36.3 0.40 1.650 41.9 251 1,344 2,000 5.6 18.5
19 x 3 x 1 7 1.3 3.8 1.465 37.2 0.40 1.693 43.0 258 1,411 2,100 5.6 18.5
1 x 2 x 1.5 7 1.6 4.1 0.429 10.9 0.32 0.579 14.7 88 208 310 3.7 12.3
2 x 2 x 1.5 7 1.6 4.1 0.717 18.2 0.32 0.882 22.4 134 423 630 3.7 12.3
4 x 2 x 1.5 7 1.6 4.1 0.846 21.5 0.32 1.024 26.0 156 551 820 3.7 12.3
5 x 2 x 1.5 7 1.6 4.1 0.945 24.0 0.32 1.122 28.5 171 645 960 3.7 12.3
8 x 2 x 1.5 7 1.6 4.1 1.063 27.0 0.32 1.248 31.7 190 796 1,185 3.7 12.3
12 x 2 x 1.5 7 1.6 4.1 1.350 34.3 0.40 1.571 39.9 239 1,243 1,850 3.7 12.3
1 x 2 x 2.5 7 2.0 4.5 0.472 12.0 0.32 0.622 15.8 95 269 400 2.30 7.56
12 x 2 x 2.5 7 2.0 4.5 1.480 37.6 0.40 1.709 43.4 260 1,411 2,100 2.30 7.56
2x2x4 7 2.5 5.3 0.898 22.8 0.32 1.075 27.3 164 605 900 1.43 4.70

1x3x1 7 1.3 3.8 0.429 10.9 0.32 0.583 14.8 89 215 320 5.6 18.5
4x3x1 7 1.3 3.8 0.909 23.1 0.32 1.087 27.6 166 591 880 5.6 18.5
1 x 3 x 1.5 7 1.6 4.1 0.461 11.7 0.32 0.614 15.6 94 249 370 3.7 12.3
10 x 3 x 1.5 7 1.6 4.1 1.469 37.3 0.40 1.697 43.1 259 1,478 2,200 3.7 12.3
16 x 3 x 1.5 7 1.6 4.1 1.819 46.2 0.40 2.063 52.4 314 1,781 2,650 3.7 12.3

Electrical characteristics for HXXMB-FR Individually shielded and isolated EEP 250 V IEC 60092-3
cross section of the mutual capacitance mutual capacitance mutual capacitance mutual capacitance loop inductance loop inductance
conductor core to core (nF/M) core to core (nF/km) core to shield (nF/M) core to shield (nF/km) (mH/M) (mH/km)
(mm2) pair & triad pair & triad pair & triad pair & triad pair & triad pair & triad
1 20 66 35 115 0.24 0.80
1.5 22 73 38 124 0.23 0.76
2.5 25 82 42 138 0.21 0.70
4 26 84 43 141 0.21 0.68

207
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 1 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Fire resistant, flame retardant
halogen-free power cable. Mud
resistant

BFOU 0,6/1kV
MGT/EPR/EPR/TCWB/EVA

NEK 606 CodeP5/P12

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Standards applied

Application IEC 60092-353 - Design


IEC 60228 class 2 - Conductor
Fixed installation for power, control and lighting in both EX- and IEC 60092-351 - Insulation
safe areas, emergency and critical systems where requirement for IEC 60092-359 - Sheath
fire resistance exists. For installation in areas exposed to MUD and IEC 60332-1 - Flame Retardant
drilling/cleaning fluids. Meets the MUD resistance requirement in IEC 60332-3-22 - Flame Retardant
NEK 606. IEC 60331-21 - Fire Resistant
IEC 60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over inner PET tape
covering
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
Outer sheath
(IEC 60092-359)
E.g. "meter" "r" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX -
Marking text
FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
Manufacturing unit DRAKA 01 = Draka Norsk Kabel
Outer sheath colour Black

www.drakaMOG.com
208
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 2 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
1 16 4 5.15 1.0 1.1 10 0.8 0.2 1.2 13 0.8 370 198
11.5 15.5
1 25 6 6.45 1.2 1.1 0.3 1.3 530 314
0.8 0.8
18.5
1 50 10 9.0 1.4 1.1 15 0.8 0.3 1.4 870 555
0.8
16.5
1 70 10 10.85 1.4 1.1 0.3 1.4 20.5 1 1110 744
0.8
18.5
1 95 10 12.60 1.6 1.1 0.3 1.5 23 1 1420 985
0.8
1 120 10 14.20 1.6 1.2 20.5 1 0.3 1.6 25 1 1730 1224
1 150 10 15.90 1.8 1.2 23 1 0.3 1.7 27.5 1 2100 1510
1 185 10 17.70 2.0 1.2 25 1 0.3 1.7 29.5 1 2500 1837
1 240 16 20.15 2.2 1.2 28 1 0.3 1.8 33 1.5 3170 2371
1 300 16 22.60 2.4 1.2 31 1.5 0.3 1.9 36 1.5 3890 2975
2 1.5 4 1.6 1.0 1.1 10 0.8 0.2 1.2 13 0.8 285 80
10.5 14.5
3G 1.5 - 1.6 1.0 1.1 0.3 1.3 360 125
0.8 0.8
11.5 15.5
4G 1.5 - 1.6 1.0 1.1 0.3 1.3 420 156
0.8 0.8
10.5 14.5
3 1.5 6 1.6 1.0 1.1 0.3 1.3 360 125
0.8 0.8
11.5 15.5
4 1.5 6 1.6 1.0 1.1 0.3 1.3 420 156
0.8 0.8
16.5
5 1.5 6 1.6 1.0 1.1 13 0.8 0.3 1.4 480 170
0.8
7 1.5 6 1.6 1.0 1.1 14 0.8 0.3 1.4 18 0.8 560 214
18.5
12 1.5 10 1.6 1.0 1.2 0.3 1.6 23 1 830 316
0.8
19 1.5 10 1.6 1.0 1.2 22 1 0.3 1.7 26.5 1 1130 438
31.5
27 1.5 16 1.6 1.0 1.2 26.5 1 0.3 1.9 1500 574
1.5
35.5
37 1.5 16 1.6 1.0 1.4 30 1.5 0.3 2 1950 741
1.5
16.5
5G 1.5 - 1.6 1.0 1.1 13 0.8 0.3 1.4 480 170
0.8
34.5
32 1.5 16 1.6 1.0 1.4 29 1 0.3 2 1800 668
1.5
7G 2.5 - 2.0 1.0 1.1 15 0.8 0.3 1.4 19 0.8 650 276
14.5
2 2.5 6 2.0 1.0 1.1 11 0.8 0.3 1.3 370 129
0.8
3G 2.5 - 2.0 1.0 1.1 11.5 0.3 1.3 15 0.8 420 169
www.drakaMOG.com
209
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 3 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
0.8
11.5
3 2.5 6 2.0 1.0 1.1 0.3 1.3 15 0.8 420 169
0.8
12.5 16.5
4G 2.5 - 2.0 1.0 1.1 0.3 1.3 480 192
0.8 0.8
12.5 16.5
4 2.5 6 2.0 1.0 1.1 0.3 1.3 480 192
0.8 0.8
19.5
8G 2.5 - 2.0 1.0 1.1 0.3 1.5 23.5 1 790 332
0.8
7 2.5 6 2.0 1.0 1.1 15 0.8 0.3 1.4 19 0.8 650 277
12 2.5 10 2.0 1.0 1.2 20.5 1 0.3 1.6 24.5 1 990 425
19 2.5 10 2.0 1.0 1.2 24 1 0.3 1.8 28.5 1 1380 611
34.5
27 2.5 16 2.0 1.0 1.4 29.5 1 0.3 2 1920 844
1.5
37 2.5 25 2.0 1.0 1.4 33 1.5 0.4 2.2 39 1.5 2570 1200
5G 2.5 - 2.0 1.0 1.1 14 0.8 0.3 1.4 18 0.8 570 231
4G 4 - 2.55 1.0 1.1 14 0.8 0.3 1.4 18 0.8 610 263
15.5 19.5
5G 4 - 2.55 1.0 1.1 0.3 1.4 700 299
0.8 0.8
15.5
2 4 6 2.55 1.0 1.1 12 0.8 0.3 1.3 450 173
0.8
16.5
3 4 6 2.55 1.0 1.1 13 0.8 0.3 1.3 510 210
0.8
4 4 6 2.55 1.0 1.1 14 0.8 0.3 1.4 18 0.8 610 263
16.5
3G 4 - 2.55 1.0 1.1 13 0.8 0.3 1.3 510 210
0.8
2 6 6 3.15 1.0 1.1 13 0.8 0.3 1.4 17 0.8 530 209
3 6 6 3.15 1.0 1.1 14 0.8 0.3 1.4 18 0.8 620 280
15.5 19.5
4 6 6 3.15 1.0 1.1 0.3 1.4 720 334
0.8 0.8
3G 6 - 3.15 1.0 1.1 14 0.8 0.3 1.4 18 0.8 620 280
15.5 19.5
4G 6 - 3.15 1.0 1.1 0.3 1.4 720 334
0.8 0.8
5G 6 - 3.15 1.0 1.1 17 0.8 0.3 1.5 21.5 1 880 405
2 10 10 4.05 1.0 1.1 15 0.8 0.3 1.4 19 0.8 680 298
3 10 10 4.05 1.0 1.1 16 0.8 0.3 1.5 20 1 800 389
4 10 10 4.05 1.0 1.1 18 0.8 0.3 1.5 22 1 960 496
3G 10 - 4.05 1.0 1.1 16 0.8 0.3 1.5 20 1 800 387
4G 10 - 4.05 1.0 1.1 18 0.8 0.3 1.5 22 1 960 494
5G 10 - 4.05 1.0 1.2 20 1 0.3 1.6 24 1 1170 600
17.5
2 16 16 5.15 1.0 1.1 0.5 1.5 22 1 990 497
0.8
18.5
3 16 16 5.15 1.0 1.1 0.4 1.5 23 1 1170 654
0.8
4 16 16 5.15 1.0 1.2 20.5 1 0.4 1.6 25.5 1 1410 799
18.5
3G 16 - 5.15 1.0 1.1 0.3 1.5 22.5 1 1090 583
0.8
5G 16 - 5.15 1.0 1.2 23 1 0.3 1.7 27.5 1 1610 896
4G 16 - 5.15 1.0 1.2 20.5 1 0.3 1.6 25 1 1330 727
2 25 16 6.45 1.2 1.2 21 1 0.4 1.6 26 1 1370 685
3 25 16 6.45 1.2 1.2 22.5 1 0.3 1.7 27 1 1600 887
4 25 16 6.45 1.2 1.2 25 1 0.3 1.8 29.5 1 1950 1116
4G 25 - 6.45 1.2 1.2 25 1 0.3 1.8 29.5 1 1930 1091
5G 25 - 6.45 1.2 1.2 27.5 1 0.3 1.8 32 1.5 2290 1345
2 35 16 7.65 1.2 1.2 23.5 1 0.3 1.7 28 1 1630 818
3 35 16 7.65 1.2 1.2 25 1 0.3 1.8 30 1.5 1990 1125
4 35 16 7.65 1.2 1.2 28 1 0.3 1.9 33 1.5 2440 1434
3G 35 - 7.65 1.2 1.2 25 1 0.3 1.8 30 1.5 1970 1101
www.drakaMOG.com
210
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 4 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
4G 35 - 7.65 1.2 1.2 28 1 0.3 1.9 33 1.5 2440 1434
36.5
5G 35 - 7.65 1.2 1.4 31 1.5 0.3 2 2980 1768
1.5
34.5
3 50 25 9.0 1.4 1.2 29 1 0.4 1.9 2710 1602
1.5
32.5
4 50 25 9.0 1.4 1.4 0.4 2 38 1.5 3350 2033
1.5
5G 50 - 9.0 1.4 1.4 36 1.5 0.4 2.2 42 2 4090 2508
32.5
4G 50 - 9.0 1.4 1.4 0.3 2 38 1.5 3260 1949
1.5
37.5
2 70 35 10.85 1.4 1.4 31 1.5 0.6 2 3120 1758
1.5
3 70 35 10.85 1.4 1.4 33 1.5 0.5 2 39 1.5 3730 2347
4 70 35 10.85 1.4 1.4 37 1.5 0.4 2.2 43 2 4550 2926
4G 70 - 10.85 1.4 1.4 37 1.5 0.4 2.2 43 2 4460 2839
5G 70 - 10.85 1.4 1.4 41 2 0.4 2.3 47 2 5380 3503
3 95 50 12.60 1.6 1.4 38 1.5 0.6 2.2 44.5 2 4910 3133
4 95 50 12.60 1.6 1.6 42.5 2 0.5 2.4 49.5 2 6090 3975
4G 95 - 12.60 1.6 1.6 42.5 2 0.4 2.4 49 2 5860 3748
5G 95 - 12.60 1.6 1.6 47 2 0.4 2.6 54 2.5 7080 4630
3 120 60 14.20 1.6 1.4 41 2 0.6 2.4 48.5 2 6000 3953
53.5
4 120 60 14.20 1.6 1.6 46 2 0.6 2.5 7430 5030
2.5
4G 120 - 14.20 1.6 1.6 46 2 0.4 2.5 53 2.5 7150 4754
59.5
4G 150 - 15.90 1.8 1.6 52 2.5 0.5 2.7 8810 5848
2.5
57.5
4G 185 - 17.70 2.0 1.8 0.5 2.9 65.5 3 10810 7248
2.5

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800200 BFOU 0.6/1kV 1X 16/4mm P5/P12 BLACK - 7021528002003 1043605
800201 BFOU 0.6/1kV 1X 25/6mm P5/P12 BLACK - 7021528002010 -
800203 BFOU 0.6/1kV 1X 50/6mm P5/P12 BLACK Yes 7021528002034 1043608
800204 BFOU 0.6/1kV 1X 70/6mm P5/P12 BLACK - 7021528002041 1043609
800205 BFOU 0.6/1kV 1X 95/10 P5/P12 BLACK Yes 7021528002058 1043610
800206 BFOU 0.6/1kV 1X 120/10 P5/P12 BLACK - 7021528002065 1043611
800207 BFOU 0.6/1kV 1X 150/10 P5/P12 BLACK Yes 7021528002072 1043612
800208 BFOU 0.6/1kV 1X 185/10 P5/P12 BLACK - 7021528002089 1043613
800209 BFOU 0.6/1kV 1X 240/16 P5/P12 BLACK - 7021528002096 -
800210 BFOU 0.6/1kV 1X 300/16 P5/P12 BLACK Yes 7021528002102 1043615
800215 BFOU 0.6/1kV 2X 1.5/4 P5/P12 BLACK Yes 7021528002157 1043620
800216 BFOU 0.6/1kV 3G 1.5mm P5/P12 BLACK - 7021528002164 1043619
800217 BFOU 0.6/1kV 4G 1.5mm P5/P12 BLACK - 7021528002171 -
800218 BFOU 0.6/1kV 3X 1.5/6 P5/P12 BLACK Yes 7021528002188 1043640
800219 BFOU 0.6/1kV 4X 1.5/6 P5/P12 BLACK Yes 7021528002195 1043660
800220 BFOU 0.6/1kV 5X 1.5/6 P5/P12 BLACK - 7021528002201 1043705
800221 BFOU 0.6/1kV 7X 1.5/6 P5/P12 BLACK Yes 7021528002218 1043707
800222 BFOU 0.6/1kV 12X 1.5/10 P5/P12 BLACK Yes 7021528002225 1043712
800223 BFOU 0.6/1kV 19X 1.5/10 P5/P12 BLACK Yes 7021528002232 1043719
800224 BFOU 0.6/1kV 27X 1.5/16 P5/P12 BLACK - 7021528002249 1043727
800225 BFOU 0.6/1kV 37X 1.5/16 P5/P12 BLACK - 7021528002256 -
800226 BFOU 0.6/1kV 5G 1.5mm P5/P12 BLACK - 7021528002263 -
800227 BFOU 0.6/1kV 32X 1.5/16 P5/P12 BLACK - 7021528002270 -
800228 BFOU 0.6/1kV 7G 2.5mm P5/P12 BLACK - 7021528002287 -
800229 BFOU 0.6/1kV 2X 2.5/6 P5/P12 BLACK Yes 7021528002294 1043621
800230 BFOU 0.6/1kV 3G 2.5mm P5/P12 BLACK Yes 7021528002300 1043639

www.drakaMOG.com
211
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 5 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800232 BFOU 0.6/1kV 3X 2.5/6 P5/P12 BLACK Yes 7021528002324 1043641
800233 BFOU 0.6/1kV 4G 2.5mm P5/P12 BLACK - 7021528002331 1043659
800235 BFOU 0.6/1kV 4X 2.5/6 P5/P12 BLACK Yes 7021528002355 1043661
800236 BFOU 0.6/1kV 8G 2.5mm P5/P12 BLACK - 7021528002362 -
800237 BFOU 0.6/1kV 7X 2.5/6 P5/P12 BLACK Yes 7021528002379 1043757
800238 BFOU 0.6/1kV 12X 2.5/10 P5/P12 BLACK Yes 7021528002386 1043762
800239 BFOU 0.6/1kV 19X 2.5/10 P5/P12 BLACK - 7021528002393 1043769
800240 BFOU 0.6/1kV 27X 2.5/16 P5/P12 BLACK - 7021528002409 1043777
800241 BFOU 0.6/1kV 37X 2.5/25 P5/P12 BLACK - 7021528002416 1043787
800242 BFOU 0.6/1kV 5G 2.5mm P5/P12 BLACK - 7021528002423 1043755
800243 BFOU 0.6/1kV 4G 4mm P5/P12 BLACK - 7021528002430 -
800244 BFOU 0.6/1kV 5G 4mm P5/P12 BLACK - 7021528002447 -
800245 BFOU 0.6/1kV 2X 4/6mm P5/P12 BLACK Yes 7021528002454 1043622
800246 BFOU 0.6/1kV 3X 4/6mm P5/P12 BLACK Yes 7021528002461 1043642
800247 BFOU 0.6/1kV 4X 4/6mm P5/P12 BLACK - 7021528002478 1043662
800250 BFOU 0.6/1kV 3G 4mm P5/P12 BLACK - 7021528002508 -
800251 BFOU 0.6/1kV 2X 6/6mm P5/P12 BLACK Yes 7021528002515 1043623
800252 BFOU 0.6/1kV 3X 6/6mm P5/P12 BLACK Yes 7021528002522 1043643
800253 BFOU 0.6/1kV 4X 6/6mm P5/P12 BLACK Yes 7021528002539 1043663
800254 BFOU 0.6/1kV 3G 6mm P5/P12 BLACK - 7021528002546 -
800255 BFOU 0.6/1kV 4G 6mm P5/P12 BLACK - 7021528002553 -
800256 BFOU 0.6/1kV 5G 6mm P5/P12 BLACK - 7021528002560 -
800257 BFOU 0.6/1kV 2X 10/10 P5/P12 BLACK - 7021528002577 1043624
800258 BFOU 0.6/1kV 3X 10/10 P5/P12 BLACK Yes 7021528002584 1043644
800259 BFOU 0.6/1kV 4X 10/10 P5/P12 BLACK - 7021528002591 1043664
800260 BFOU 0.6/1kV 3G 10mm P5/P12 BLACK - 7021528002607 -
800261 BFOU 0.6/1kV 4G 10mm P5/P12 BLACK - 7021528002614 -
800262 BFOU 0.6/1kV 5G 10mm P5/P12 BLACK - 7021528002621 -
800263 BFOU 0.6/1kV 2X 16/16 P5/P12 BLACK - 7021528002638 1043625
800264 BFOU 0.6/1kV 3X 16/16 P5/P12 BLACK Yes 7021528002645 1043645
800265 BFOU 0.6/1kV 4X 16/16 P5/P12 BLACK Yes 7021528002652 1043665
800266 BFOU 0.6/1kV 3G 16mm P5/P12 BLACK - 7021528002669 -
800267 BFOU 0.6/1kV 5G 16mm P5/P12 BLACK - 7021528002676 -
800268 BFOU 0.6/1kV 4G 16mm P5/P12 BLACK - 7021528002683 -
800269 BFOU 0.6/1kV 2X 25/16 P5/P12 BLACK - 7021528002690 1043626
800270 BFOU 0.6/1kV 3X 25/16 P5/P12 BLACK Yes 7021528002706 1043646
800271 BFOU 0.6/1kV 4X 25/16 P5/P12 BLACK Yes 7021528002713 1043666
800272 BFOU 0.6/1kV 4G 25mm P5/P12 BLACK - 7021528002720 -
800273 BFOU 0.6/1kV 5G 25mm P5/P12 BLACK - 7021528002737 -
800275 BFOU 0.6/1kV 2X 35/16 P5/P12 BLACK - 7021528002751 1043627
800276 BFOU 0.6/1kV 3X 35/16 P5/P12 BLACK Yes 7021528002768 1043647
800277 BFOU 0.6/1kV 4X 35/16 P5/P12 BLACK - 7021528002775 1043667
800278 BFOU 0.6/1kV 3G 35mm P5/P12 BLACK - 7021528002782 -
800279 BFOU 0.6/1kV 4G 35mm P5/P12 BLACK - 7021528002799 -
800280 BFOU 0.6/1kV 5G 35mm P5/P12 BLACK - 7021528002805 -
800282 BFOU 0.6/1kV 3X 50/25 P5/P12 BLACK Yes 7021528002829 1043648
800283 BFOU 0.6/1kV 4X 50/25 P5/P12 BLACK Yes 7021528002836 1043668
800284 BFOU 0.6/1kV 5G 50mm P5/P12 BLACK - 7021528002843 -
800285 BFOU 0.6/1kV 4G 50mm P5/P12 BLACK - 7021528002850 -
800287 BFOU 0.6/1kV 2X 70/35 P5/P12 BLACK - 7021528002874 1043629
800288 BFOU 0.6/1kV 3X 70/35 P5/P12 BLACK Yes 7021528002881 1043649
800289 BFOU 0.6/1kV 4X 70/35 P5/P12 BLACK - 7021528002898 1043669
800290 BFOU 0.6/1kV 4G 70mm P5/P12 BLACK - 7021528002904 -
800291 BFOU 0.6/1kV 5G 70mm P5/P12 BLACK - 7021528002911 -
800295 BFOU 0.6/1kV 3X 95/50 P5/P12 BLACK Yes 7021528002959 1043650
800296 BFOU 0.6/1kV 4X 95/50 P5/P12 BLACK Yes 7021528002966 1043670
800297 BFOU 0.6/1kV 4G 95mm P5/P12 BLACK - 7021528002973 -
800298 BFOU 0.6/1kV 5G 95mm P5/P12 BLACK - 7021528002980 -
800301 BFOU 0.6/1kV 3X 120/60 P5/P12 BLACK Yes 7021528003017 1043651
800304 BFOU 0.6/1kV 4X 120/60 P5/P12 BLACK - 7021528003048 -
800306 BFOU 0.6/1kV 4G 120mm P5/P12 BLACK - 7021528003062 -
www.drakaMOG.com
212
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 6 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800307 BFOU 0.6/1kV 4G 150mm P5/P12 BLACK - 7021528003079 -
800310 BFOU 0.6/1kV 4G 185mm P5/P12 BLACK - 7021528003109 -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
1 16 4 STCC 1.16 1.48 0.118 0.142 96 2240
1 25 6 STCC 0.734 0.936 0.114 0.136 127 3500
1 50 10 STCC 0.391 0.499 0.105 0.126 196 7000
1 70 10 STCC 0.27 0.344 0.1 0.12 242 9800
1 95 10 STCC 0.195 0.249 0.097 0.116 293 13300
1 120 10 STCC 0.154 0.196 0.095 0.114 339 16800
1 150 10 STCC 0.126 0.161 0.094 0.112 389 21000
1 185 10 STCC 0.1 0.128 0.092 0.11 444 25900
1 240 16 STCC 0.0762 0.0972 0.09 0.108 522 33600
1 300 16 STCC 0.0607 0.0774 0.088 0.106 601 42000
2 1.5 4 STCC 12.2 15.6 0.115 0.138 20 210
3G 1.5 - STCC 12.2 15.6 0.115 0.138 20 210
4G 1.5 - STCC 12.2 15.6 0.115 0.138 16 210
3 1.5 6 STCC 12.2 15.6 0.115 0.138 16 210
4 1.5 6 STCC 12.2 15.6 0.115 0.138 16 210
5 1.5 6 STCC 12.2 15.6 0.115 0.138 13.5 210
7 1.5 6 STCC 12.2 15.6 0.115 0.138 12 210
12 1.5 10 STCC 12.2 15.6 0.115 0.138 10 210
19 1.5 10 STCC 12.2 15.6 0.115 0.138 8.5 210
27 1.5 16 STCC 12.2 15.6 0.115 0.138 7.5 210
37 1.5 16 STCC 12.2 15.6 0.115 0.138 7 210
5G 1.5 - STCC 12.2 15.6 0.115 0.138 16 210
32 1.5 16 STCC 12.2 15.6 0.115 0.138 7 210
7G 2.5 - STCC 7.56 9.64 0.107 0.129 16.5 350
2 2.5 6 STCC 7.56 9.64 0.107 0.129 26 350
3G 2.5 - STCC 7.56 9.64 0.107 0.129 26 350
3 2.5 6 STCC 7.56 9.64 0.107 0.129 21 350
4G 2.5 - STCC 7.56 9.64 0.107 0.129 21 350
4 2.5 6 STCC 7.56 9.64 0.107 0.129 21 350
8G 2.5 - STCC 7.56 9.64 0.107 0.129 15.5 350
7 2.5 6 STCC 7.56 9.64 0.107 0.129 15.5 350
12 2.5 10 STCC 7.56 9.64 0.107 0.129 13 350
19 2.5 10 STCC 7.56 9.64 0.107 0.129 11 350
27 2.5 16 STCC 7.56 9.64 0.107 0.129 10 350
37 2.5 25 STCC 7.56 9.64 0.107 0.129 9 350
5G 2.5 - STCC 7.56 9.64 0.107 0.129 21 350
4G 4 - STCC 4.7 5.99 0.1 0.120 28 560
5G 4 - STCC 4.7 5.99 0.1 0.120 28 560
2 4 6 STCC 4.7 5.99 0.100 0.120 34 560
3 4 6 STCC 4.7 5.99 0.100 0.120 28 560
4 4 6 STCC 4.7 5.99 0.1 0.120 28 560
3G 4 - STCC 4.7 5.99 0.1 0.120 34 560
2 6 6 STCC 3.11 3.97 0.094 0.112 44 840
3 6 6 STCC 3.11 3.97 0.094 0.112 36 840
4 6 6 STCC 3.11 3.97 0.094 0.112 36 840
3G 6 - STCC 3.11 3.97 0.094 0.112 44 840
4G 6 - STCC 3.11 3.97 0.094 0.112 36 840
5G 6 - STCC 3.11 3.97 0.094 0.112 36 840
2 10 10 STCC 1.84 2.35 0.088 0.105 61 1400
3 10 10 STCC 1.84 2.35 0.088 0.105 50 1400
4 10 10 STCC 1.84 2.35 0.088 0.105 50 1400

www.drakaMOG.com
213
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 7 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
3G 10 - STCC 1.84 2.35 0.088 0.105 61 1400
4G 10 - STCC 1.84 2.35 0.088 0.105 50 1400
5G 10 - STCC 1.84 2.35 0.088 0.105 50 1400
2 16 16 STCC 1.16 1.48 0.082 0.099 80 2240
3 16 16 STCC 1.16 1.48 0.082 0.099 67 2240
4 16 16 STCC 1.16 1.48 0.082 0.099 67 2240
3G 16 - STCC 1.16 1.48 0.082 0.099 80 2240
5G 16 - STCC 1.16 1.48 0.082 0.099 67 2240
4G 16 - STCC 1.16 1.48 0.082 0.099 67 2240
2 25 16 STCC 0.734 0.936 0.081 0.098 108 3500
3 25 16 STCC 0.734 0.936 0.081 0.098 89 3500
4 25 16 STCC 0.734 0.936 0.081 0.098 89 3500
4G 25 - STCC 0.734 0.936 0.081 0.098 89 3500
5G 25 - STCC 0.734 0.936 0.081 0.098 89 3500
2 35 16 STCC 0.529 0.675 0.078 0.094 133 4900
3 35 16 STCC 0.529 0.675 0.078 0.094 110 4900
4 35 16 STCC 0.529 0.675 0.078 0.094 110 4900
3G 35 - STCC 0.529 0.675 0.078 0.094 133 4900
4G 35 - STCC 0.529 0.675 0.078 0.094 110 4900
5G 35 - STCC 0.529 0.675 0.078 0.094 110 4900
3 50 25 STCC 0.391 0.499 0.078 0.093 137 7000
4 50 25 STCC 0.391 0.499 0.078 0.093 137 7000
5G 50 - STCC 0.391 0.499 0.078 0.093 137 7000
4G 50 - STCC 0.391 0.499 0.078 0.093 137 7000
2 70 35 STCC 0.27 0.344 0.075 0.092 206 9800
3 70 35 STCC 0.27 0.344 0.077 0.092 169 9800
4 70 35 STCC 0.27 0.344 0.077 0.092 169 9800
4G 70 - STCC 0.27 0.344 0.075 0.092 169 9800
5G 70 - STCC 0.27 0.344 0.075 0.092 169 9800
3 95 50 STCC 0.195 0.249 0.075 0.090 205 13300
4 95 50 STCC 0.195 0.249 0.075 0.090 205 13300
4G 95 - STCC 0.195 0.249 0.075 0.090 205 13300
5G 95 - STCC 0.195 0.249 0.075 0.090 205 13300
3 120 60 STCC 0.154 0.196 0.073 0.088 237 16800
4 120 60 STCC 0.154 0.196 0.073 0.088 237 16800
4G 120 - STCC 0.154 0.196 0.073 0.088 237 16800
4G 150 - STCC 0.126 0.161 0.073 0.088 272 21000
4G 185 - STCC 0.1 0.128 0.073 0.088 311 25900

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius Minimum Bending Radius Fixed Maximum Tensile Load Minimum Installation
during Installation Installed During Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
214
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 8 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Fire resistant, flame retardant
halogen-free power cable. Mud
resistant. Single core cable.

BFOU 0,6/1kV
MGT/EPR/EPR/TCWB/EVA

NEK 606 CodeP5/P12

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Standards applied

Application IEC 60092-353/60502-1 - Design


IEC 60228 class 2 - Conductor
Fixed installation for power, control and lighting in both EX- and IEC 60092-351 - Insulation
safe areas, emergency and critical systems where requirement IEC 60092-359 - Sheath
for fire resistance exists. For installation in areas exposed to IEC 60332-1 - Flame Retardant
MUD and drilling/cleaning fluids. Meets the MUD resistance IEC 60332-3-22 - Flame Retardant
requirement in NEK 606. IEC 60331-21 - Fire Resistant
IEC 60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over inner PET tape
covering
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
Outer sheath
(IEC 60092-359)
E.g. "meter" "r" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX -
Marking text
FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
Manufacturing unit DRAKA 01 = Draka Norsk Kabel
Outer sheath colour Black

www.drakaMOG.com
215
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 9 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Core identification power cables
Single core Black
Two cores - Blue Brown
Three cores - Brown - Black Grey
Four cores - Blue - Brown - Black Grey
Five cores - Blue - Brown - Black - Grey Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue Brown
Three cores + earth (4G) - Yellow/green - Brown - Black Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
1 400 25 26.00 2.4 1.4 35 1.5 0.4 2.1 41 2 5100 3940
1 630 25 32.80 2.8 1.4 42 2 0.4 2.3 48.5 2 7660 6167

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800211 BFOU 0.6/1kV 1X 400/25 P5/P12 BLACK - 7021528002119 -
800213 BFOU 0.6/1kV 1X 630/25 P5/P12 BLACK - 7021528002133 -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
690 dc / 670
1 400 25 STCC 0.0475 0.0606 0.088 0.105 56000
ac
890dc / 780
1 630 25 STCC 0.0286 0.0606 0.084 0.101 88200
ac

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
216
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 10 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Fire resistant, flame retardant
halogen-free power cable. Mud
resistant. Double braided.

BFOU 0,6/1kV
MGT/EPR/EPR/TCWB/EVA

NEK 606 CodeP5/P12

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Standards applied

Application IEC 60092-353 - Design


IEC 60228 class 2 - Conductor
Fixed installation for power, control and lighting in both EX- and IEC 60092-351 - Insulation
safe areas, emergency and critical systems where requirement for IEC 60092-359 - Sheath
fire resistance exists. For installation in areas exposed to MUD and IEC 60332-1 - Flame Retardant
drilling/cleaning fluids. Meets the MUD resistance requirement in IEC 60332-3-22 - Flame Retardant
NEK 606. IEC 60331-21 - Fire Resistant
IEC 60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over inner PET tape + rubberized Polyamide tape
covering
Armour/screen O Two layers of tinned copper wire braid (double braid)
Tape over PET tape + rubberized Polyamide tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
Outer sheath
(IEC 60092-359)
E.g. "meter" "r" DRAKA 01 BFOU 0,6/1kV P5/P12 3 x 25/16 mm2 FLEX -
Marking text
FLAME IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
Manufacturing unit DRAKA 01 = Draka Norsk Kabel
Outer sheath colour Black

www.drakaMOG.com
217
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 11 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
54.5
3 150 70 15.90 1.8 1.4 46 2 0.4 2.6 7390 4870
2.5
4 150 70 15.90 1.8 1.6 52 2.5 0.5 2.8 61 3 9380 6352
65.0
3 240 120 19.1 2.2 2.0 56.0 2.0 0.7 3.0 11950 8059
3.0
57.5
4 185 95 17.7 2.0 1.8 0.4 2.9 683 11640 7750
2.5
51.5
3 185 95 17.70 2.0 1.6 0.5 2.8 61 3 9370 6291
2.5

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800302 BFOU 0.6/1kV 3X 150/70 P5/P12 BLACK Yes 7021528003024 1043652
800309 BFOU 0.6/1kV 4X 150/70 P5/P12 BLACK - 7021528003093 -
800314 BFOU 0.6/1kV 3X 240/120 P5/P12 BLACK - 7021528003147 -
800391 BFOU 0.6/1kV 4X 185/95 P5/P12 BLACK - 7021528003918 -
800392 BFOU 0.6/1kV 3X 185/95 P5/P12 BLACK - 7021528003925 -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
3 150 70 KGTFR 0.126 0.161 0.073 0.088 272 21000
4 150 70 KGTFR 0.126 0.161 0.073 0.088 272 21000
3 240 120 KGTFR 0.0762 0.0972 0.074 0.089 365 33600
4 185 95 KGTFR 0.1 0.128 0.073 0.088 311 25900
3 185 95 KGTFR 0.1 0.128 0.073 0.088 311 25900

www.drakaMOG.com
218
BFOU 1kV(4).doc
03/06/2008 09:00:00
Page 12 of 12

FlexFlame BFOU 0,6/1kV P5/P12 Power cable


Ambient temperature correction factors
Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
219
BFOU(C) 250V(3).doc
04/06/2008 10:57:00
Page 1 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable


Fire resistant, flame retardant halogen-
free instrumentation cable. Mud resistant

BFOU(c) 250V
MGT/EPR/EPR/TCWB/EVA

NEK 606 CodeS4/S8

Operating temperature : 90C


Operating Voltage : 250V

Standards applied

Application IEC 60092-376 (2003-05) - Design


IEC 60228 class 2 - Conductor
Fixed installation for instrumentation, communication, control and IEC 60092-351 - Insulation
alarm systems in both EX- and safe areas, emergency and critical IEC 60092-359 - Sheath
systems where requirement for fire resistance exists. Meets the IEC 60332-1 - Flame Retardant
mud resistant requirements in NEK 606. IEC 60332-3-22 - Flame Retardant
IEC 60331-21, -31 - Fire Resistant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
Pair / Triple / are laid up collectively and screened by copper backed polyester tape with tinned
Quad twisting copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over inner PET tape
covering
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
Eg. "meter" "year" DRAKA 01 BFOU(c) 250V S4/S8 4 PAIR 0,75 mm2 FLEX -
Marking text
FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
Manufacturing DRAKA 01 = Draka Norsk Kabel
unit
Outer sheath Grey or Blue
colour

www.drakaMOG.com
220
BFOU(C) 250V(3).doc
04/06/2008 10:57:00
Page 2 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable


Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey

Range and dimensions


Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number No of Conductor Insulation
section Inner inner Braid Outer outer of Cable content
of cores in Diameter, Thickness,
core, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements element mm mm
mm mm mm mm mm mm (Kg/Km) (kg/km)
10.5 14.5
2 2 0.75 1.1 0.6 1.1 0.3 1.3 340 114
0.8 0.8
10.5 14.5
2 2 0.75 1.1 0.6 1.1 0.3 1.3 340 114
0.8 0.8
12.5
4 2 0.75 1.1 0.6 1.1 0.3 1.4 16 0.8 450 156
0.8
12.5
4 2 0.75 1.1 0.6 1.1 0.3 1.4 16 0.8 450 156
0.8
16.5
8 2 0.75 1.1 0.6 1.1 0.3 1.5 20.5 1 680 240
0.8
16.5
8 2 0.75 1.1 0.6 1.1 0.3 1.5 20.5 1 680 240
0.8
19.5
12 2 0.75 1.1 0.6 1.3 0.3 1.6 23.5 1 920 333
0.8
19.5
12 2 0.75 1.1 0.6 1.3 0.3 1.6 23.5 1 920 333
0.8
16 2 0.75 1.1 0.6 1.4 21 1 0.3 1.7 25.5 1 1090 384
16 2 0.75 1.1 0.6 1.4 21 1 0.3 1.7 25.5 1 1090 384
19 2 0.75 1.1 0.6 1.4 22 1 0.3 1.8 27 1 1240 447
31.5
24 2 0.75 1.1 0.6 1.8 26.5 1 0.3 2 1590 536
1.5
31.5
24 2 0.75 1.1 0.6 1.8 26.5 1 0.3 2 1590 536
1.5
15.5
2 3 0.75 1.1 0.6 1.1 12 0.8 0.3 1.3 400 143
0.8
15.5
2 3 0.75 1.1 0.6 1.1 12 0.8 0.3 1.3 400 143
0.8
4 3 0.75 1.1 0.6 1.1 14 0.8 0.3 1.4 18 0.8 550 198
4 3 0.75 1.1 0.6 1.1 14 0.8 0.3 1.4 18 0.8 550 198
18.5
8 3 0.75 1.1 0.6 1.1 0.3 1.6 23 1 870 309
0.8
18.5
8 3 0.75 1.1 0.6 1.1 0.3 1.6 23 1 870 309
0.8
12 3 0.75 1.1 0.6 1.3 22 1 0.3 1.8 26.5 1 1160 411
12 3 0.75 1.1 0.6 1.3 22 1 0.3 1.8 26.5 1 1160 411
16 3 0.75 1.1 0.6 1.4 24 1 0.3 1.9 29 1 1440 513
16 3 0.75 1.1 0.6 1.4 24 1 0.3 1.9 29 1 1440 513
35.5
24 3 0.75 1.1 0.6 1.8 30 1.5 0.4 2.1 2180 823
1.5
16.5
2 2 1.5 1.6 0.7 1.1 13 0.8 0.3 1.4 440 162
0.8
16.5
2 2 1.5 1.6 0.7 1.1 13 0.8 0.3 1.4 440 162
0.8
4 2 1.5 1.6 0.7 1.1 15 0.8 0.3 1.4 19 0.8 590 235
4 2 1.5 1.6 0.7 1.1 15 0.8 0.3 1.4 19 0.8 590 235
8 2 1.5 1.6 0.7 1.1 20 1 0.3 1.7 24.5 1 980 404
8 2 1.5 1.6 0.7 1.1 20 1 0.3 1.7 24.5 1 980 404
12 2 1.5 1.6 0.7 1.3 23.5 1 0.3 1.8 28.5 1 1300 541
12 2 1.5 1.6 0.7 1.3 23.5 1 0.3 1.8 28.5 1 1300 541
16 2 1.5 1.6 0.7 1.4 26 1 0.3 1.9 30.5 1600 678
www.drakaMOG.com
221
BFOU(C) 250V(3).doc
04/06/2008 10:57:00
Page 3 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable


Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number No of Conductor Insulation
section Inner inner Braid Outer outer of Cable content
of cores in Diameter, Thickness,
core, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements element mm mm
mm mm mm mm mm mm (Kg/Km) (kg/km)
1.5
30.5
16 2 1.5 1.6 0.7 1.4 26 1 0.3 1.9 1600 678
1.5
38.5
24 2 1.5 1.6 0.7 1.8 32 1.5 0.4 2.2 2430 1031
1.5
38.5
24 2 1.5 1.6 0.7 1.8 32 1.5 0.4 2.2 2430 1031
1.5
14.5 18.5
2 3 1.5 1.6 0.7 1.1 0.3 1.4 530 208
0.8 0.8
14.5 18.5
2 3 1.5 1.6 0.7 1.1 0.3 1.4 530 208
0.8 0.8
4 3 1.5 1.6 0.7 1.1 17 0.8 0.3 1.5 21 1 740 308
4 3 1.5 1.6 0.7 1.1 17 0.8 0.3 1.5 21 1 740 308
8 3 1.5 1.6 0.7 1.1 22.5 1 0.3 1.8 27 1 1240 518
8 3 1.5 1.6 0.7 1.1 22.5 1 0.3 1.8 27 1 1240 518
12 3 1.5 1.6 0.7 1.3 27 1 0.3 1.9 32 1.5 1690 736
35.5
16 3 1.5 1.6 0.7 1.6 30 1.5 0.4 2.1 2300 1035
1.5
35.5
16 3 1.5 1.6 0.7 1.6 30 1.5 0.4 2.1 2300 1035
1.5
24 3 1.5 1.6 0.7 2 37 1.5 0.4 2.4 43.5 2 3280 1418
2 2 2.5 2 0.7 1.1 14 0.8 0.3 1.4 18 0.8 520 217
16.5
4 2 2.5 2 0.7 1.1 0.3 1.5 20.5 1 730 325
0.8
8 2 2.5 2 0.7 1.1 22 1 0.3 1.8 27 1 1210 551
16 2 2.5 2 0.7 1.6 29 1 0.4 2.1 35 1.5 2200 1053
24 2 2.5 2 0.7 2 36 1.5 0.4 2.4 42.5 2 3220 1509
8 3 2.5 2 0.7 1.1 25 1 0.3 1.9 30 1.5 1600 762
39.5
16 3 2.5 2 0.7 1.6 33 1.5 0.4 2.3 2940 1471
1.5

Electrical values instrumentation cables


Capacitance, approx. Inductance, approx, Resistance at 20C, max. L/R ratio,
Type
(nF/km) (mH/km) (Ohm/km) (microH/Ohm)
Unshielded pair 0,75 mm 100 0,67 26,3 12,7
Unshielded triple 0,75 mm 100 0,67 26,3 12,7
Unshielded pair 1,5 mm 110 0,63 12,2 26,6
Unshielded triple 1,5 mm 110 0,63 12,2 26,6
Unshielded pair 2,5 mm 125 0,59 7,56 39,0
Unshielded triple 2,5 mm 125 0,59 7,56 39,0

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
893806 BFOU(C) 2PAIR 0.75mm S4/S8 GREY Yes 7021528938067 1043821
893807 BFOU(C) 2PAIR 0.75mm S4/S8 BLUE Yes 7021528938074 1043822
893818 BFOU(C) 4PAIR 0.75mm S4/S8 GREY Yes 7021528938180 1043823
893819 BFOU(C) 4PAIR 0.75mm S4/S8 BLUE Yes 7021528938197 1043824
893830 BFOU(C) 8PAIR 0.75mm S4/S8 GREY Yes 7021528938302 1043828
893831 BFOU(C) 8PAIR 0.75mm S4/S8 BLUE Yes 7021528938319 1043829
893836 BFOU(C) 12PAIR 0.75mm S4/S8 GREY Yes 7021528938364 1043830
893837 BFOU(C) 12PAIR 0.75mm S4/S8 BLUE - 7021528938371 1043831
893842 BFOU(C) 16PAIR 0.75mm S4/S8 GREY Yes 7021528938425 1043833
893843 BFOU(C) 16PAIR 0.75mm S4/S8 BLUE Yes 7021528938432 1043834

www.drakaMOG.com
222
BFOU(C) 250V(3).doc
04/06/2008 10:57:00
Page 4 of 4

FlexFlame BFOU(c) 250V S4/S8 Instr. cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
893845 BFOU(C) 19PAIR 0.75mm S4/S8 GREY - 7021528938456 -
893848 BFOU(C) 24PAIR 0.75mm S4/S8 GREY Yes 7021528938487 1043836
893849 BFOU(C) 24PAIR 0.75mm S4/S8 BLUE Yes 7021528938494 1043837
893866 BFOU(C) 2TRIP 0.75mm S4/S8 GREY Yes 7021528938661 1043921
893867 BFOU(C) 2TRIP 0.75mm S4/S8 BLUE Yes 7021528938678 1043922
893878 BFOU(C) 4TRIP 0.75mm S4/S8 GREY Yes 7021528938784 1043924
893879 BFOU(C) 4TRIP 0.75mm S4/S8 BLUE - 7021528938791 1043925
893890 BFOU(C) 8TRIP 0.75mm S4/S8 GREY - 7021528938906 1043928
893891 BFOU(C) 8TRIP 0.75mm S4/S8 BLUE - 7021528938913 1043929
893896 BFOU(C) 12TRIP 0.75mm S4/S8 GREY - 7021528938968 1043930
893897 BFOU(C) 12TRIP 0.75mm S4/S8 BLUE - 7021528938975 1043931
893902 BFOU(C) 16TRIP 0.75mm S4/S8 GREY Yes 7021528939026 1043933
893903 BFOU(C) 16TRIP 0.75mm S4/S8 BLUE - 7021528939033 1043934
893908 BFOU(C) 24TRIP 0.75mm S4/S8 GREY - 7021528939088 1043936
894006 BFOU(C) 2PAIR 1.5mm S4/S8 GREY Yes 7021528940060 1043862
894007 BFOU(C) 2PAIR 1.5mm S4/S8 BLUE - 7021528940077 1043861
894018 BFOU(C) 4PAIR 1.5mm S4/S8 GREY Yes 7021528940183 1043863
894019 BFOU(C) 4PAIR 1.5mm S4/S8 BLUE - 7021528940190 1043864
894030 BFOU(C) 8PAIR 1.5mm S4/S8 GREY Yes 7021528940305 1043868
894031 BFOU(C) 8PAIR 1.5mm S4/S8 BLUE - 7021528940312 1043869
894036 BFOU(C) 12PAIR 1.5mm S4/S8 GREY Yes 7021528940367 1043870
894037 BFOU(C) 12PAIR 1.5mm S4/S8 BLUE - 7021528940374 1043871
894042 BFOU(C) 16PAIR 1.5mm S4/S8 GREY Yes 7021528940428 1043873
894043 BFOU(C) 16PAIR 1.5mm S4/S8 BLUE - 7021528940435 1043874
894048 BFOU(C) 24PAIR 1.5mm S4/S8 GREY Yes 7021528940480 1043876
894049 BFOU(C) 24PAIR 1.5mm S4/S8 BLUE - 7021528940497 1043877
894066 BFOU(C) 2TRIP 1.5mm S4/S8 GREY Yes 7021528940664 1043971
894067 BFOU(C) 2TRIP 1.5mm S4/S8 BLUE Yes 7021528940671 1043972
894078 BFOU(C) 4TRIP 1.5mm S4/S8 GREY - 7021528940787 1043973
894079 BFOU(C) 4TRIP 1.5mm S4/S8 BLUE - 7021528940794 1043974
894090 BFOU(C) 8TRIP 1.5mm S4/S8 GREY Yes 7021528940909 1043977
894091 BFOU(C) 8TRIP 1.5mm S4/S8 BLUE - 7021528940916 1043978
894096 BFOU(C) 12TRIP 1.5mm S4/S8 GREY - 7021528940961 1043979
894102 BFOU(C) 16TRIP 1.5mm S4/S8 GREY - 7021528941029 1043981
894103 BFOU(C) 16TRIP 1.5mm S4/S8 BLUE - 7021528941036 1043982
894108 BFOU(C) 24TRIP 1.5mm S4/S8 GREY - 7021528941081 1043987
894206 BFOU(C) 2PAIR 2.5mm S4/S8 GREY - 7021528942064 -
894218 BFOU(C) 4PAIR 2.5mm S4/S8 GREY - 7021528942187 -
894230 BFOU(C) 8PAIR 2.5mm S4/S8 GREY - 7021528942309 -
894242 BFOU(C) 16PAIR 2.5mm S4/S8 GREY - 7021528942422 -
894248 BFOU(C) 24PAIR 2.5mm S4/S8 GREY - 7021528942484 -
894290 BFOU(C) 8TRIP 2.5mm S4/S8 GREY - 7021528942903 -
894302 BFOU(C) 16TRIP 2.5mm S4/S8 GREY - 7021528943023 -

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
223
BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 1 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant

BFOU(i) 250V
MGT/EPR/EPR/TCWB/EVA

NEK 606 CodeS3/S7

Operating temperature : 90C


Operating Voltage : 250V

Standards applied

Application IEC 60092-376 (2003-05) - Design


IEC 60228 class 2 - Conductor
Fixed installation for instrumentation, communication, control IEC 60092-351 - Insulation
and alarm systems in both EX- and safe areas, emergency IEC 60092-359 - Sheath
and critical systems where requirement for fire resistance IEC 60332-1 - Flame Retardant
exists. Meets the mud resistant requirements in NEK 606. IEC 60332-3-22 - Flame Retardant
IEC 60331-21, -31 - Fire Resistant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
Pair / Triple /
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
Quad twisting
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Lay up / Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped
Shielding with a PETP tape.
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over inner PET tape
covering
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
Eg. "meter" "year" DRAKA 01 BFOU(i) 250V S3/S7 16 PAIR 0,75 mm2 FLEX -
Marking text
FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22 ETL Classified No. 3067229
Manufacturing DRAKA 01 = Draka Norsk Kabel
unit
Outer sheath Grey or Blue
colour

www.drakaMOG.com
224
BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 2 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey

Range and dimensions


Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number No of Conductor Insulation
section Inner inner Braid Outer outer of Cable content
of cores in Diameter, Thickness,
core, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements element mm mm
mm mm mm mm mm mm (Kg/Km) (kg/km)
10.5
1 2 0.75 1.1 0.6 1.1 7.5 0.5 0.2 1.1 200 55
0.8
10.5
1 2 0.75 1.1 0.6 1.1 7.5 0.5 0.2 1.1 200 55
0.8
14.5
2 2 0.75 1.1 0.6 1.1 11 0.8 0.3 1.3 360 135
0.8
14.5
2 2 0.75 1.1 0.6 1.1 11 0.8 0.3 1.3 360 135
0.8
12.5 16.5
4 2 0.75 1.1 0.6 1.1 0.3 1.4 490 186
0.8 0.8
12.5 16.5
4 2 0.75 1.1 0.6 1.1 0.3 1.4 490 186
0.8 0.8
8 2 0.75 1.1 0.6 1.1 17 0.8 0.3 1.6 21.5 1 780 288
8 2 0.75 1.1 0.6 1.1 17 0.8 0.3 1.6 21.5 1 780 288
12 2 0.75 1.1 0.6 1.3 20.5 1 0.3 1.7 25 1 1050 381
12 2 0.75 1.1 0.6 1.3 20.5 1 0.3 1.7 25 1 1050 381
16 2 0.75 1.1 0.6 1.4 23 1 0.3 1.8 27.5 1 1310 475
16 2 0.75 1.1 0.6 1.4 23 1 0.3 1.8 27.5 1 1310 475
19 2 0.75 1.1 0.6 1.4 24 1 0.3 1.9 28.5 1 1460 526
19 2 0.75 1.1 0.6 1.4 24 1 0.3 1.9 28.5 1 1460 526
34.5
24 2 0.75 1.1 0.6 1.8 29 1 0.4 2.1 2000 723
1.5
34.5
24 2 0.75 1.1 0.6 1.8 29 1 0.4 2.1 2000 723
1.5
1 3 0.75 1.1 0.6 1.1 8 0.5 0.2 1.1 11 0.8 220 68
1 3 0.75 1.1 0.6 1.1 8 0.5 0.2 1.1 11 0.8 220 68
15.5
2 3 0.75 1.1 0.6 1.1 12 0.8 0.3 1.4 410 147
0.8
15.5
2 3 0.75 1.1 0.6 1.1 12 0.8 0.3 1.4 410 147
0.8
17.5
4 3 0.75 1.1 0.6 1.1 14 0.8 0.3 1.4 570 212
0.8
17.5
4 3 0.75 1.1 0.6 1.1 14 0.8 0.3 1.4 570 212
0.8
18.5
8 3 0.75 1.1 0.6 1.1 0.3 1.7 23 1 970 364
0.8
18.5
8 3 0.75 1.1 0.6 1.1 0.3 1.7 23 1 970 364
0.8
12 3 0.75 1.1 0.6 1.3 22.5 1 0.3 1.8 27 1 1300 484
12 3 0.75 1.1 0.6 1.3 22.5 1 0.3 1.8 27 1 1300 484
16 3 0.75 1.1 0.6 1.4 25.5 1 0.3 1.9 30 1.5 1630 604
31.5
19 3 0.75 1.1 0.6 1.6 26.5 1 0.3 2 1850 675
1.5
31.5 37.5
24 3 0.75 1.1 0.6 1.8 0.4 2.2 2460 924
1.5 1.5
31.5 37.5
24 3 0.75 1.1 0.6 1.8 0.4 2.2 2460 924
1.5 1.5
1 2 1.5 1.6 0.7 1.1 9 0.5 0.2 1.1 12 0.8 255 79
1 2 1.5 1.6 0.7 1.1 9 0.5 0.2 1.1 12 0.8 255 79
2 2 1.5 1.6 0.7 1.1 13 0.8 0.3 1.4 17 0.8 470 186
2 2 1.5 1.6 0.7 1.1 13 0.8 0.3 1.4 17 0.8 470 186
www.drakaMOG.com
225
BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 3 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number No of Conductor Insulation
section Inner inner Braid Outer outer of Cable content
of cores in Diameter, Thickness,
core, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements element mm mm
mm mm mm mm mm mm (Kg/Km) (kg/km)
15.5 19.5
4 2 1.5 1.6 0.7 1.1 0.3 1.5 660 271
0.8 0.8
15.5 19.5
4 2 1.5 1.6 0.7 1.1 0.3 1.5 660 271
0.8 0.8
8 2 1.5 1.6 0.7 1.1 21 1 0.3 1.7 25.5 1 1080 451
8 2 1.5 1.6 0.7 1.1 21 1 0.3 1.7 25.5 1 1080 451
12 2 1.5 1.6 0.7 1.3 25 1 0.3 1.9 30 1.5 1490 613
12 2 1.5 1.6 0.7 1.3 25 1 0.3 1.9 30 1.5 1490 613
16 2 1.5 1.6 0.7 1.6 29 1 0.3 2 34 1.5 1920 776
16 2 1.5 1.6 0.7 1.6 29 1 0.3 2 34 1.5 1920 776
35.5
19 2 1.5 1.6 0.7 1.6 30 1.5 0.4 2.1 2290 1009
1.5
35.5
24 2 1.5 1.6 0.7 1.8 0.4 2.3 42 2 2900 1226
1.5
35.5
24 2 1.5 1.6 0.7 1.8 0.4 2.3 42 2 2970 1226
1.5
12.5
1 3 1.5 1.6 0.7 1.1 9.5 0.5 0.2 1.2 285 93
0.8
12.5
1 3 1.5 1.6 0.7 1.1 9.5 0.5 0.2 1.2 285 93
0.8
14.5 18.5
2 3 1.5 1.6 0.7 1.1 0.3 1.5 550 214
0.8 0.8
14.5 18.5
2 3 1.5 1.6 0.7 1.1 0.3 1.5 560 214
0.8 0.8
4 3 1.5 1.6 0.7 1.1 17 0.8 0.3 1.6 21 1 810 344
4 3 1.5 1.6 0.7 1.1 17 0.8 0.3 1.6 21 1 810 344
8 3 1.5 1.6 0.7 1.1 22.5 1 0.3 1.8 27 1 1360 589
8 3 1.5 1.6 0.7 1.1 22.5 1 0.3 1.8 27 1 1360 589
33.5
12 3 1.5 1.6 0.7 1.5 28.5 1 0.3 2 1920 810
1.5
33.5
12 3 1.5 1.6 0.7 1.5 28.5 1 0.3 2 1920 810
1.5
31.5 37.5
16 3 1.5 1.6 0.7 1.6 0.4 2.2 2600 1180
1.5 1.5
31.5 37.5
16 3 1.5 1.6 0.7 1.6 0.4 2.2 2600 1180
1.5 1.5
39.5
24 3 1.5 1.6 0.7 2 0.4 2.5 46.5 2 3720 1611
1.5
39.5
24 3 1.5 1.6 0.7 2 0.4 2.5 46.5 2 3720 1611
1.5
1 2 2.5 2 0.7 1.1 9.5 0.5 0.2 1.2 13 0.8 300 99
1 2 2.5 2 0.7 1.1 9.5 0.5 0.2 1.2 13 0.8 300 99
14.5 18.5
2 2 2.5 2 0.7 1.1 0.3 1.5 550 225
0.8 0.8
4 2 2.5 2 0.7 1.1 17 0.8 0.3 1.6 21.5 1 820 367
8 2 2.5 2 0.7 1.1 23.5 1 0.3 1.8 28 1 1370 633
16 2 2.5 2 0.7 1.6 32 1.5 0.4 2.2 38 1.5 2590 1221
10.5 13.5
1 3 2.5 2 0.7 1.1 0.2 1.2 350 129
0.8 0.8
30.5
8 3 2.5 2 0.7 1.3 25.5 1 0.3 2 1790 844
1.5
31.5 37.5
12 3 2.5 2 0.7 1.5 0.4 2.2 2610 1284
1.5 1.5

www.drakaMOG.com
226
BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 4 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Electrical values instrumentation cables
Capacitance, approx. Inductance, approx, Resistance at 20C, max. L/R ratio,
Type
(nF/km) (mH/km) (Ohm/km) (microH/Ohm)
Shielded pair 0,75 mm 110 0,67 26,3 12,7
Shielded triple 0,75 mm 110 0,67 26,3 12,7
Shielded pair 1,5 mm 125 0,63 12,2 26,6
Shielded triple 1,5 mm 125 0,63 12,2 26,6
Shielded pair 2,5 mm 145 0,59 7,56 39,0
Shielded triple 2,5 mm 145 0,59 7,56 39,0

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
893200 BFOU(I) 1PAIR 0.75mm S3/S7 GREY Yes 7021528932003 1043820
893201 BFOU(I) 1PAIR 0.75mm S3/S7 BLUE Yes 7021528932010 1043819
893206 BFOU(I) 2PAIR 0.75mm S3/S7 GREY Yes 7021528932065 1044020
893207 BFOU(I) 2PAIR 0.75mm S3/S7 BLUE - 7021528932072 1044019
893218 BFOU(I) 4PAIR 0.75mm S3/S7 GREY Yes 7021528932188 1044021
893219 BFOU(I) 4PAIR 0.75mm S3/S7 BLUE - 7021528932195 1044022
893230 BFOU(I) 8PAIR 0.75mm S3/S7 GREY Yes 7021528932300 1044028
893231 BFOU(I) 8PAIR 0.75mm S3/S7 BLUE - 7021528932317 1044029
893236 BFOU(I) 12PAIR 0.75mm S3/S7 GREY - 7021528932362 1044030
893237 BFOU(I) 12PAIR 0.75mm S3/S7 BLUE - 7021528932379 1044031
893242 BFOU(I) 16PAIR 0.75mm S3/S7 GREY Yes 7021528932423 1044033
893243 BFOU(I) 16PAIR 0.75mm S3/S7 BLUE - 7021528932430 1044034
893245 BFOU(I) 19PAIR 0.75mm S3/S7 GREY Yes 7021528932454 -
893246 BFOU(I) 19PAIR 0.75mm S3/S7 BLUE Yes 7021528932461 -
893248 BFOU(I) 24PAIR 0.75mm S3/S7 GREY - 7021528932485 1044036
893249 BFOU(I) 24PAIR 0.75mm S3/S7 BLUE - 7021528932492 1044037
893260 BFOU(I) 1TRIP 0.75mm S3/S7 GREY Yes 7021528932607 1043920
893261 BFOU(I) 1TRIP 0.75mm S3/S7 BLUE Yes 7021528932614 1043919
893266 BFOU(I) 2TRIP 0.75mm S3/S7 GREY - 7021528932669 1044121
893267 BFOU(I) 2TRIP 0.75mm S3/S7 BLUE - 7021528932676 1044122
893278 BFOU(I) 4TRIP 0.75mm S3/S7 GREY - 7021528932782 1044123
893279 BFOU(I) 4TRIP 0.75mm S3/S7 BLUE - 7021528932799 1044124
893290 BFOU(I) 8TRIP 0.75mm S3/S7 GREY Yes 7021528932904 1044128
893291 BFOU(I) 8TRIP 0.75mm S3/S7 BLUE - 7021528932911 1044129
893296 BFOU(I) 12TRIP 0.75mm S3/S7 GREY - 7021528932966 1044130
893297 BFOU(I) 12TRIP 0.75mm S3/S7 BLUE - 7021528932973 1044131
893302 BFOU(I) 16TRIP 0.75mm S3/S7 GREY - 7021528933024 1044132
893305 BFOU(I) 19TRIP 0.75mm S3/S7 GREY - 7021528933055 -
893308 BFOU(I) 24TRIP 0.75mm S3/S7 GREY - 7021528933086 1044138
893309 BFOU(I) 24TRIP 0.75mm S3/S7 BLUE - 7021528933093 1044139
893400 BFOU(I) 1PAIR 1.5mm S3/S7 GREY Yes 7021528934007 1043860
893401 BFOU(I) 1PAIR 1.5mm S3/S7 BLUE Yes 7021528934014 1043859
893406 BFOU(I) 2PAIR 1.5mm S3/S7 GREY Yes 7021528934069 1044060
893407 BFOU(I) 2PAIR 1.5mm S3/S7 BLUE - 7021528934076 1044061
893418 BFOU(I) 4PAIR 1.5mm S3/S7 GREY Yes 7021528934182 1044063
893419 BFOU(I) 4PAIR 1.5mm S3/S7 BLUE - 7021528934199 1044064
893430 BFOU(I) 8PAIR 1.5mm S3/S7 GREY Yes 7021528934304 1044068
893431 BFOU(I) 8PAIR 1.5mm S3/S7 BLUE - 7021528934311 1044069
893436 BFOU(I) 12PAIR 1.5mm S3/S7 GREY Yes 7021528934366 1044070
893437 BFOU(I) 12PAIR 1.5mm S3/S7 BLUE - 7021528934373 1044071
893442 BFOU(I) 16PAIR 1.5mm S3/S7 GREY Yes 7021528934427 1044073
893443 BFOU(I) 16PAIR 1.5mm S3/S7 BLUE - 7021528934434 1044074
893445 BFOU(I) 19PAIR 1.5mm S3/S7 GREY Yes 7021528934458 -
893448 BFOU(I) 24PAIR 1.5mm S3/S7 GREY - 7021528934489 1044076
893449 BFOU(I) 24PAIR 1.5mm S3/S7 BLUE - 7021528934496 -
893460 BFOU(I) 1TRIP 1.5mm S3/S7 GREY Yes 7021528934601 1044170
www.drakaMOG.com
227
BFOU(I) 250V(3).doc
04/06/2008 10:39:00
Page 5 of 5

FlexFlame BFOU(i) 250V S3/S7 Instr. cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
893461 BFOU(I) 1TRIP 1.5mm S3/S7 BLUE Yes 7021528934618 1044169
893466 BFOU(I) 2TRIP 1.5mm S3/S7 GREY - 7021528934663 1044171
893467 BFOU(I) 2TRIP 1.5mm S3/S7 BLUE - 7021528934670 -
893478 BFOU(I) 4TRIP 1.5mm S3/S7 GREY - 7021528934786 1044173
893479 BFOU(I) 4TRIP 1.5mm S3/S7 BLUE - 7021528934793 1044174
893490 BFOU(I) 8TRIP 1.5mm S3/S7 GREY - 7021528934908 1044177
893491 BFOU(I) 8TRIP 1.5mm S3/S7 BLUE - 7021528934915 1044178
893496 BFOU(I) 12TRIP 1.5mm S3/S7 GREY - 7021528934960 1044179
893497 BFOU(I) 12TRIP 1.5mm S3/S7 BLUE - 7021528934977 1044180
893502 BFOU(I) 16TRIP 1.5mm S3/S7 GREY - 7021528935028 1044181
893503 BFOU(I) 16TRIP 1.5mm S3/S7 BLUE - 7021528935035 1044182
893508 BFOU(I) 24TRIP 1.5mm S3/S7 GREY - 7021528935080 1044193
893509 BFOU(I) 24TRIP 1.5mm S3/S7 BLUE - 7021528935097 1044194
893600 BFOU(I) 1PAIR 2.5mm S3/S7 GREY Yes 7021528936001 1044140
893601 BFOU(I) 1PAIR 2.5mm S3/S7 BLUE - 7021528936018 -
893606 BFOU(I) 2PAIR 2.5mm S3/S7 GREY - 7021528936063 -
893618 BFOU(I) 4PAIR 2.5mm S3/S7 GREY - 7021528936186 -
893630 BFOU(I) 8PAIR 2.5mm S3/S7 GREY - 7021528936308 -
893642 BFOU(I) 16PAIR 2.5mm S3/S7 GREY - 7021528936421 -
893660 BFOU(I) 1TRIP 2.5mm S3/S7 GREY - 7021528936605 -
893690 BFOU(I) 8TRIP 2.5mm S3/S7 GREY - 7021528936902 -
893696 BFOU(I) 12TRIP 2.5mm S3/S7 GREY - 7021528936964 -

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
228
BFOU-HCF(c)-250V-HF_2006.doc
30.06.2006 08:52
Page 1 of 2

BFOU-HCF(c) 250V S16 / 1100C / 30 minutes


HydroCarbon Fire resistant, flame retardant
halogen-free instrumentation cable.

BFOU-HCF(c) 250V
MGT/EPR/EPR/TCWB/EVA/HCF/SHF1
2 3
5 4

NEK 606 Code S16


1

1100C / 2000F / 200 kW/m


Operating temperature : 90C
Operating Voltage : 250V

Standards applied

IEC 60092-376 (2003-05) - Design


Application Draka Norsk Kabel - HCF protection
IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for instrumentation, communication,
IEC 60092-359 - Sheath
control and alarm systems in both EX- and safe areas,
emergency and critical systems where requirement for IEC 60332-1 - Flame Retardant
hydrocarbon fire resistance is vital. IEC 60332-3-22 - Flame Retardant
IEC 60331-21 - Fire Resistant
UL 1709 / ASTM E1529 - HC Fire resistance
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned stranded circular copper, IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
Pair / Triple / are laid up collectively and screened by copper backed polyester tape with tinned
Quad twisting copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over PET tape
bedding
Armour/screen O Tinned copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
HCF protection -HCF Extruded heatblock compound
Tape Lapped glassfibre tape
Overall sheath Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-359)

www.drakaMOG.com
229
BFOU-HCF(c)-250V-HF_2006.doc
30.06.2006 08:52
Page 2 of 2

BFOU-HCF(c) 250V S16 / 1100C / 30 minutes


Code
Letter
Eg. "meter" "r" DRAKA NORSK KABEL BFOU-HCF(c) 250V S16 4 PAIR 1,5 mm2
Marking text
HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Outer sheath Grey
colour

Core identification instrumentation cables


Pair Black - Light Blue
Triple Black - Light Blue - Brown

Range and dimensions


Draka Type Diameter Thickness of Diameter Diameter Weight
Norsk Kabel over bedding armour sheath overall HCF- of cable
part no. [mm2] [mm] wires protection approx.
[mm] [mm] [kg/km]
(mm)

2 pair 1,5 13,00,8 0,3 16,50,8 44,52,0 2400


886562 4 pair 1,5 15,00,8 0,3 19,00,8 46,52,0 2650
8 pair 1,5 20,51,0 0,3 25,01,0 53,02,5 3570
12 pair 1,5 23,51,0 0,3 28,51,0 57,02,5 4160

Electrical values instrumentation cables


TYPE Capacitance Inductance Resist. 20C
approx. approx.
[mm2] [nF/km] [mH/km] [Max.ohm/km]

Multi pair 1,5 110 0,63 12,2

Installation recommendations
TYPE Overall Minimum bending radius Maximum
Diameter During Fixed pulling tension
[mm2] [mm] Installation Installed [N]
[mm]
20 x D 12 x D

2 pair 1,5 44,52,0 890 534 300


4 pair 1,5 46,52,0 930 558 600
8 pair 1,5 53,02,5 1060 636 1200
12 pair 1,5 57,02,5 1140 684 1800

Minimum installation temperature: - 10 C

www.drakaMOG.com
230
BFOU-HCF(i)-250V-HF_2006.doc
30.06.2006 08:46
Page 1 of 2

BFOU-HCF(i) 250V S15 / 1100C / 30 minutes


HydroCarbon Fire resistant, flame retardant
halogen-free instrumentation cable.

BFOU-HCF(i) 250V
MGT/EPR/EPR/TCWB/EVA/HCF/SHF1
2 3
5 4

NEK 606 Code S15


1

1100C / 2000F / 200 kW/m


Operating temperature : 90C
Operating Voltage : 250V

Standards applied

IEC 60092-376 (2003-05) - Design


Application Draka Norsk Kabel - HCF protection
IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for instrumentation, communication,
IEC 60092-359 - Sheath
control and alarm systems in both EX- and safe areas,
emergency and critical systems where requirement for IEC 60332-1 - Flame Retardant
hydrocarbon fire resistance is vital. IEC 60332-3-22 - Flame Retardant
IEC 60331-21 - Fire Resistant
UL 1709 / ASTM E1529 - HC Fire resistance
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned stranded circular copper, IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
Pair / Triple /
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
Quad twisting
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over PET tape
bedding
Armour/screen O Tinned copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
HCF protection -HCF Extruded heatblock compound
Tape Lapped glassfibre tape

www.drakaMOG.com
231
BFOU-HCF(i)-250V-HF_2006.doc
30.06.2006 08:46
Page 2 of 2

BFOU-HCF(i) 250V S15 / 1100C / 30 minutes


Code
Letter
Overall sheath Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-359)
Eg. "meter" "r" DRAKA NORSK KABEL BFOU-HCF(i) 250V S15 4 PAIR 1,5 mm2
Marking text
HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Outer sheath Grey
colour

Core identification instrumentation cables


Pair Black - Light Blue
Triple Black - Light Blue - Brown

Range and dimensions


Draka Type Diameter Thickness of Diameter Diameter Weight
Norsk Kabel over bedding armour sheath overall HCF- of cable
part no. [mm2] [mm] wires protection approx.
[mm] [mm] [kg/km]
(mm)

886563 1 pair 1,5 9,00,5 0,2 12,00,8 39,51,5 1880


2 pair 1,5 13,00,8 0,3 17,00,8 44,52,0 2450
4 pair 1,5 15,50,8 0,3 19,50,8 47,52,0 2830
8 pair 1,5 21.01,0 0,3 25,51,0 54,52,5 3690
12 pair 1,5 25,01,0 0,3 30.01,5 63,03.0 5200

Electrical values instrumentation cables


TYPE Capacitance Inductance Resist. 20C
approx. approx.
[mm2] [nF/km] [mH/km] [Max.ohm/km]

single pair 1,5 125 0,63 12,2

Installation recommendations
TYPE Overall Minimum bending radius Maximum
Diameter During Fixed pulling tension
[mm2] [mm] Installation Installed [N]
[mm]
20 x D 12 x D

1 pair 1,5 39,51,5 790 474 150


2 pair 1,5 44,52,0 890 534 300
4 pair 1,5 47,52,0 950 570 600
8 pair 1,5 54,52,5 1090 654 1200
12 pair 1,5 63,03.0 1260 756 1800

Minimum installation temperature: - 10 C

www.drakaMOG.com
232
BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 1 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


HydroCarbon Fire resistant, flame retardant
halogen-free power cable.

BFOU-HCF 0,6/1kV
MGT/EPR/EPR/TCWB/EVA/HCF/SHF1

NEK 606 Code P34

1100C / 2000F / 200 kW/m


Operating temperature : 90C
Operating Voltage : 0,6/1kV

Standards applied

IEC 60092-353 - Design


Draka Norsk Kabel - HCF protection
Application IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for power, control and lightning in both IEC 60092-359 - Sheath
EX- and safe areas, emergency and critical systems IEC 60332-1 - Flame Retardant
where requirement for fire resistance is vital. IEC 60332-3-22 - Flame Retardant
IEC 60331-21 - Fire Resistant
UL 1709 / ASTM E1529 - HC Fire resistance
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code Letter
Conductor Tinned stranded circular copper, IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over bedding PET tape
Armour/screen O Tinned copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound,
Outer sheath
SHF2 (IEC 60092-359)
HCF protection -HCF Extruded heatblock compound
Tape Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-
Overall sheath
359)
Eg. "meter" "r" DRAKA NORSK KABEL BFOU-HCF 0,6/1kV P34 12 x
Marking text
2,5/10 mm2 HCF 1100/30 FLEX - FLAME IEC 60331-21 IEC 60332-3-22
Outer sheath Black
colour
www.drakaMOG.com
233
BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 2 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


Core identification power cables
Single core Grey (Offwhite)
Two cores Grey (Offwhite) - Black
Three cores Grey (Offwhite) - Black - Red
Four cores Grey (Offwhite) - Black - Red - Blue
Five cores Grey (Offwhite) - Black - Red - Blue - Black
Above five cores Black numbers on white base
Separate earth core Yellow/green
G / x in cable describtion G = one of the core are yellow/green - x = no yellow/green core

Range and dimensions


Draka Type Diameter Thickness of Diameter Diameter Weight
Norsk Kabel over bedding armour sheath overall HCF- of cable
part no. [mm2] [mm] wires protection approx.
[mm] [mm] [kg/km]
(mm)

1x 50/6 15,00,8 0,20 18,50,8 45,52,5 2900


1x 70/6 16,50,8 0,30 20,51,0 47,52,5 3300
1x 95/10 18,50,8 0,30 23,01,0 50,53,0 3800
1x 120/10 20,51,0 0,30 25,01,0 52,53,0 4260
1x 150/10 23,01,0 0,30 27,01,0 54,53,0 4750
1x 185/10 25,01,0 0,30 29,51,0 57,53,0 5380
886549 1x 240/16 28,01,0 0,30 32,51,5 66,03,5 7050
1x 300/16 30,51,5 0,30 35,51,5 68,03,5 8000

886375 2x 1,5/4 10,00,8 0,20 13,00,8 40,52,5 1890

3x 1,5/4 10,50,8 0,20 14,00,8 42.02,5 2140


886338 3x 2,5/6 11,50,8 0,30 15,00,8 42,52,5 2200
885499 3x 4/6 13,00,8 0,30 16,50,8 43,02,5 2400
885882 3x 6/6 14,00,8 0,30 18,00,8 45,02,5 2600
885138 3x 16/16 18,50,8 0,40 23,01,0 50,03,0 3500
3x 35/16 25,01,0 0,30 29,51,0 57,53,0 4840
3x 70/35 33,01,5 0,50 39,01,5 72,04,0 8150
3x 120/60 41,02,0 0,60 48,02,0 81,54,5 11300
3x 150/70 46,02,0 0,40 * 54,52,5 88,54,5 13300

886547 4x 2,5/6 12.5 0.8 0.30 16.5 0.8 44,02,5 2300


4x 6/6 15.5 0.8 0.30 19.5 0.8 47,52,5 2870
886546 4x 16/16 20.5 1.0 0.40 25.5 1.0 53,53,0 3830

7x 1,5/6 14,00,8 0,30 17,50,8 44,52,5 2550


885139 12x 1,5/10 18,50,8 0,30 22,51,0 50,03,0 3140

www.drakaMOG.com
234
BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 3 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


Draka Type Diameter Thickness of Diameter Diameter Weight
Norsk Kabel over bedding armour sheath overall HCF- of cable
part no. [mm2] [mm] wires protection approx.
[mm] [mm] [kg/km]
(mm)
885124 7x 2,5/6 15,00,8 0,30 19,00,8 46,02,5 2760
886036 12x 2,5/10 20,51,0 0,30 24,51,0 52,03,0 3500

886548 27x 1,5/16 26.51.0 0.30 31.01.5 64,53,5 5070

* This cable has a double braid (two layers of wires)

ELECTRICAL DATA
No. of cores Conductor resistance Reactance Impedance Continous Short circuit
x cross DC [/km] [/km] at 90 current [Ampere]
section [/km] C rating
at 20 C at 90 C at 50 / 60 At 50 / 60 Hz at 45 C 1 sec 0,3 sec
Hz

1 X 50/6 0,391 0,4986 0,161/0,193 0,524/0,535 196 7000 12780


1 X 70/6 0,270 0,344 0,152/0,182 0,376/0,390 242 9800 17892
1 X 95/10 0,195 0,2486 0,146/0,176 0,289/0,305 293 13300 24282
1 X 120/10 0,154 0,1964 0,141/0,170 0,242/0,260 339 16800 30672
1 X 150/10 0,126 0,161 0,137/0,164 0,211/0,223 389 21000 38340
1 X 185/10 0,100 0,128 0,133/0,160 0,185/0,205 444 25900 47286
1 X 240/16 0,0762 0,0972 0,133/0,159 0,165/0,187 522 3360 61344
1 X 300/16 0,0607 0,0774 0,128/0,154 0,150/0,173 601 42000 76681

2x 1,5/4 12,2 15,56 0,115/0,138 15,556/15,567 20 210 383

3x 1,5/4 12,2 15,56 0,115/0,138 15,556/15,567 16 210 383


3x 2,5/6 7,56 9,64 0,107/0,129 9,640/9,641 21 350 639
3x 4/6 4,70 5,99 0,100/0,120 5,993/5,994 28 560 1022
3x 6/6 3,11 3,97 0,094/0,112 3,967/3,9672 36 840 1534
3x 16/16 1,16 1,46 0082/0,099 1,481/1,482 67 2240 4089
3x 35/16 0,529 0,675 0,078/0,094 0,679/0,681 110 4900 8946
3x 70/35 0,270 0,344 0,077/0,092 0,352/0,356 169 9800 17892
3x 120/60 0,154 0,196 0,073/0,088 0,209/0,215 237 16800 30672
3x 150/70 0,126 0,161 0,073/0,088 0,177/0,183 272 21000 38340

4x 2,5/6 7,56 9,64 0,107/0,129 9,640/9,641 21 350 639


4x 6/6 3,11 3,97 0,094/0,112 3,967/3,9672 36 840 1534
4x 16/16 1,16 1,46 0082/0,099 1,481/1,482 67 2240 4089

7x 1,5/6 12,2 15,56 0,115/0,138 15,556/15,567 12 210 383


12x 1,5/10 12,2 15,56 0,115/0,138 15,556/15,567 10 210 383

7x 2,5/6 7,56 9,64 0,107/0,129 9,640/9,641 15,5 350 639

www.drakaMOG.com
235
BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 4 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


No. of cores Conductor resistance Reactance Impedance Continous Short circuit
x cross DC [/km] [/km] at 90 current [Ampere]
section [/km] C rating
at 20 C at 90 C at 50 / 60 At 50 / 60 Hz at 45 C 1 sec 0,3 sec
Hz
12x 2,5/10 7,56 9,64 0,107/0,129 9,640/9,641 13 350 639

27x 1,5/16 12,2 15,56 0,115/0,138 15,556/15,567 7,5 210 383

INSTALLATION DATA

TYPE Overall Minimum bending radius Maximum


Diameter During Fixed pulling tension
[mm2] [mm] Installation Installed [N]
[mm]
20 x D 12 x D

1x 50/6 45,52,5 910 546 2500


1x 70/6 47,52,5 950 570 3500
1x 95/10 50,53,0 1010 606 4750
1x 120/10 52,53,0 1050 630 6000
1x 150/10 54,53,0 1090 654 7500
1x 185/10 57,53,0 1150 690 9250
1x 240/16 66,03,5 1320 792 12000
1x 300/16 68,03,5 1360 816 15000

2x 1,5/4 40,52,5 810 486 150

3x 1,5/4 42,02,5 840 504 225


3x 2,5/6 42,52,5 850 510 375
3x 4/6 43,02,5 860 516 600
3x 6/6 45,02,5 900 540 900
3x 16/16 50,03,0 1000 600 2400
3x 35/16 57,53,0 1150 690 5250
3x 70/35 72,04,0 1440 864 10500
3x 120/60 81,54,5 1630 978 18000
3x 150/70 88,54,5 1770 1062 20000

4x 2,5/6 44,02,5 880 528 500


4x 6/6 47,52,5 950 570 1200
4x 16/16 53,53,0 1070 642 3200

7x 1,5/6 44,52,5 890 536 525


12 x 1,5/10 50,03,0 1000 600 900

7x 2,5/6 46,02,5 920 552 875


12x 2,5/10 52,03,0 1040 624 1500

www.drakaMOG.com
236
BFOU-HCF-1kv-HF_2006_rev2.doc
30.06.2006 08:54
Page 5 of 5

BFOU-HCF 0,6/1kV P34 / 1100C / 30-60 minutes


TYPE Overall Minimum bending radius Maximum
Diameter During Fixed pulling tension
[mm2] [mm] Installation Installed [N]
[mm]
27x 1,5/16 64,53,5 1290 774 2025

Minimum installation temperature: - 10 C

www.drakaMOG.com
237
BU 1kV(3).doc
29.12.2006 10:42
Page 1 of 4

BU 0,6/1kV P17, Power cable, Unarmoured


Fire resistant, flame retardant halogen-
free power cable. Mud resistant

BU 0,6/1kV
MGT/EPR/EVA

NEK 606 CodeP17

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Standards applied

Application IEC 60092-353 - Design


IEC 60228 class 2 - Conductor
Fixed installation for power, control and lighting in safe areas, IEC 60092-351 - Insulation
emergency and critical systems where requirement for fire IEC 60092-359 - Sheath
resistance exists. For installation in areas exposed to MUD and IEC 60332-1 - Flame Retardant
drilling/cleaning fluids. Single core cables are double-insulated IEC 60332-3-22 - Flame Retardant
battery cables. IEC 60331-21 - Fire Resistant
IEC 60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering No inner covering. (Additional tapes may be applied)
Armour/screen No armour.
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
Outer sheath
(IEC 60092-359)
E.g. "meter" "r" DRAKA NORSK KABEL BU 0,6/1kV P17 1 x 70 mm2 IEC
Marking text
60331-21 IEC 60332-3-22
Outer sheath Black
colour

www.drakaMOG.com
238
BU 1kV(3).doc
29.12.2006 10:42
Page 2 of 4

BU 0,6/1kV P17, Power cable, Unarmoured


Core identification power cables
Single core Grey (Offwhite)
Two cores Grey (Offwhite) - Black
Three cores Grey (Offwhite) - Black - Red
Four cores Grey (Offwhite) - Black - Red - Blue
Five cores Grey (Offwhite) - Black - Red - Blue - Black
Above five cores Black numbers on white base
Separate earth core Yellow/green
G / x in cable description G = one of the core are yellow/green - x = no yellow/green core

From Q3 2007 the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow
Cenelec HD 308S2 colours:
Single core Black
Two cores Blue - Brown
Two cores + earth Blue - Brown - Yellow/green
Three cores Brown - Black - Grey
Three cores + earth Brown - Black - Grey - Yellow/green
Four cores Blue - Brown - Black - Grey
Four cores + earth Blue - Brown - Black - Grey - Yellow/green
Five cores Blue - Brown - Black - Grey - Black
Above five cores Black numbers on white base

Range and dimensions


Copper
Cross Thickness Diameter Weight of Cable
Number of Conductor Insulation content
section Outer Sheath, outer sheath, Approx.
elements Diameter, mm Thickness, mm Approx.
core, mm mm mm (Kg/Km)
(kg/km)
1 16 5.15 1.0 1.1 10 0.8 235 144
1 25 6.45 1.2 1.1 11.5 0.8 350 229
1 35 7.65 1.2 1.2 13 0.8 450 308
1 50 9.0 1.4 1.2 15 0.8 610 430
1 70 10.85 1.4 1.3 17 0.8 840 620
1 95 12.60 1.6 1.4 19.5 0.8 1110 836
1 120 14.20 1.6 1.4 21 1 1380 1075
1 150 15.90 1.8 1.5 23.5 1 1700 1336
1 185 17.70 2.0 1.6 26 1 2100 1663
1 10 4.05 1.0 1 8.5 0.5 160 90
2 1.5 1.6 1.0 1.1 10 0.8 150 28
3G 1.5 1.6 1.0 1.1 10.5 0.8 175 42
3 1.5 1.6 1.0 1.1 10.5 0.8 175 42
7 1.5 1.6 1.0 1.3 14.5 0.8 330 98
19 1.5 1.6 1.0 1.5 22.5 1 760 264
2 2.5 2.0 1.0 1.1 11 0.8 185 46
3G 2.5 2.0 1.0 1.2 11.5 0.8 220 69
3 2.5 2.0 1.0 1.1 11.5 0.8 215 69
4G 2.5 2.0 1.0 1.2 13 0.8 265 92
5G 2.5 2.0 1.0 1.3 14.5 0.8 340 114
12 2.5 2.0 1.0 1.4 21 1 650 275
3 4 2.55 1.0 1.2 13 0.8 295 110
3G 4 2.55 1.0 1.2 13 0.8 295 110
2 6 3.15 1.0 1.2 13.5 0.8 310 109
3 6 3.15 1.0 1.2 14.5 0.8 380 164

www.drakaMOG.com
239
BU 1kV(3).doc
29.12.2006 10:42
Page 3 of 4

BU 0,6/1kV P17, Power cable, Unarmoured


Copper
Cross Thickness Diameter Weight of Cable
Number of Conductor Insulation content
section Outer Sheath, outer sheath, Approx.
elements Diameter, mm Thickness, mm Approx.
core, mm mm mm (Kg/Km)
(kg/km)
5G 6 3.15 1.0 1.3 17.5 0.8 580 272
3 10 4.05 1.0 1.4 16.5 0.8 550 271
3 16 5.15 1.0 1.4 19 0.8 780 433
3 25 6.45 1.2 1.5 22.5 1 1160 688
3 35 7.65 1.2 1.7 26 1 1550 927
3 50 9.0 1.4 1.9 30 1.5 2120 1293
3 150 15.9 1.8 2.3 48 2 5910 4020

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
801200 BU 0.6/1kV 1X 16mm P17 BLACK - 7021528012002 -
801201 BU 0.6/1kV 1X 25mm P17 BLACK - 7021528012019 -
801202 BU 0.6/1kV 1X 35mm P17 BLACK - 7021528012026 -
801203 BU 0.6/1kV 1X 50mm P17 BLACK - 7021528012033 1061203
801204 BU 0.6/1kV 1X 70mm P17 BLACK - 7021528012040 -
801205 BU 0.6/1kV 1X 95mm P17 BLACK - 7021528012057 1061205
801206 BU 0.6/1kV 1X 120mm P17 BLACK - 7021528012064 -
801207 BU 0.6/1kV 1X 150mm P17 BLACK - 7021528012071 1061207
801208 BU 0.6/1kV 1X 185mm P17 BLACK - 7021528012088 -
801214 BU 0.6/1kV 1X 10mm P17 BLACK - 7021528012149 -
801215 BU 0,6/1KV 2X 1,5 MM2 P17 BLACK - 7021528012156 -
801216 BU 0.6/1kV 3G 1.5mm P17 BLACK - 7021528012163 -
801218 BU 0,6/1KV 3X 1,5 MM2 P17 BLACK - 7021528012187 -
801225 BU 0,6/1KV 7X 1,5 MM2 P17 BLACK - 7021528012255 -
801228 BU 0.6/1kV 19X 1.5mm P17 BLACK - 7021528012286 -
801233 BU 0.6/1kV 2X 2.5mm P17 BLACK - 7021528012330 -
801234 BU 0.6/1kV 3G 2.5mm P17 BLACK Yes 7021528012347 -
801236 BU 0,6/1KV 3X 2,5 MM2 P17 BLACK - 7021528012361 -
801237 BU 0.6/1kV 4G 2.5mm P17 BLACK - 7021528012378 -
801240 BU 0.6/1kV 5G 2.5mm P17 BLACK - 7021528012408 -
801245 BU 0.6/1kV 12X 2.5mm P17 BLACK - 7021528012453 -
801253 BU 0,6/1KV 3X 4 MM2 P17 BLACK - 7021528012538 -
801254 BU 0.6/1kV 3G 4mm P17 BLACK - 7021528012545 -
801259 BU 0,6/1KV 2X 6 MM2 P17 BLACK - 7021528012590 -
801261 BU 0,6/1KV 3X 6 MM2 P17 BLACK - 7021528012613 -
801263 BU 0,6/1KV 5G 6 mm P17 BLACK - 7021528012637 -
801267 BU 0,6/1KV 3X 10 MM2 P17 BLACK - 7021528012675 -
801273 BU 0,6/1KV 3X 16 MM2 P17 BLACK - 7021528012736 -
801279 BU 0,6/1KV 3X 25 mm P17 BLACK - 7021528012798 -
801286 BU 0,6/1KV 3X 35 mm P17 BLACK - 7021528012866 -
801292 BU 0,6/1KV 3X 50 mm P17 BLACK - 7021528012927 -
801298 BU 0,6/1KV 3X 150 mm P17 BLACK - 7021528012989 -

Electrical values power cables


Number of Cross Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
elements section resistance at resistance at 50Hz, 60Hz, IEC 60092-352 rating 1
core, mm 20C, Ohm/km 90C, Ohm/km Ohm/km Ohm/km Table B.4, second,
Ampere Ampere
1 16 1.16 1.48 0.100 0.120 96 2240
1 25 0.734 0.936 0.097 0.117 127 3500

www.drakaMOG.com
240
BU 1kV(3).doc
29.12.2006 10:42
Page 4 of 4

BU 0,6/1kV P17, Power cable, Unarmoured


Number of Cross Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
elements section resistance at resistance at 50Hz, 60Hz, IEC 60092-352 rating 1
core, mm 20C, Ohm/km 90C, Ohm/km Ohm/km Ohm/km Table B.4, second,
Ampere Ampere
1 35 0.529 0.675 0.093 0.111 157 4900
1 50 0.391 0.499 0.091 0.109 196 7000
1 70 0.27 0.344 0.087 0.105 242 9800
1 95 0.195 0.249 0.085 0.102 293 13300
1 120 0.154 0.196 0.084 0.100 339 16800
1 150 0.126 0.161 0.083 0.100 389 21000
1 185 0.1 0.128 0.083 0.100 444 25900
1 10 1.84 2.35 0.108 0.130 72 1400
2 1.5 12.2 15.6 0.115 0.138 20 210
3G 1.5 12.2 15.6 0.115 0.138 20 210
3 1.5 12.2 15.6 0.115 0.138 16 210
7 1.5 12.2 15.6 0.115 0.138 12 210
19 1.5 12.2 15.6 0.115 0.138 8.5 210
2 2.5 7.56 9.64 0.107 0.129 26 350
3G 2.5 7.56 9.64 0.107 0.129 26 350
3 2.5 7.56 9.64 0.107 0.129 21 350
4G 2.5 7.56 9.64 0.107 0.129 21 350
5G 2.5 7.56 9.64 0.107 0.129 21 350
12 2.5 7.56 15.6 0.115 0.138 13 350
3 4 4.7 5.99 0.100 0.120 28 560
3G 4 4.7 9.64 0.107 0.129 34 560
2 6 3.11 3.97 0.094 0.112 44 840
3 6 3.11 3.97 0.094 0.112 36 840
5G 6 3.11 3.97 0.094 0.112 36 840
3 10 1.84 2.35 0.088 0.105 50 1400
3 16 1.16 1.48 0.082 0.099 67 2240
3 25 0.734 0.936 0.079 0.095 89 3500
3 35 0.529 0.675 0.078 0.094 110 4900
3 50 0.391 0.499 0.078 0.093 137 7000
3 150 0.126 0.161 0.073 0.088 272 21000

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
241
BU(c) 250V(3).doc
29.12.2006 10:20
Page 1 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured


Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant

BU(c) 250V
MGT/EPR/EVA

NEK 606 CodeS14

Operating temperature : 90C


Operating Voltage : 250V

Standards applied

Application IEC 60092-376 (2003-05) - Design


IEC 60228 class 2 - Conductor
Fixed installation for instrumentation, communication, control IEC 60092-351 - Insulation
and alarm systems in both EX-(Zone 2) and safe areas, IEC 60092-359 - Sheath
emergency and critical systems where requirement for fire IEC 60332-1 - Flame Retardant
resistance exists. Meets the mud resistant requirements in IEC 60332-3-22 - Flame Retardant
NEK 606. IEC 60331-21 - Fire Resistant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
Pair / Triple / are laid up collectively and screened by copper backed polyester tape with tinned
Quad twisting copper drain wire.Pairs/triples are identified by numbered tape or by numbers
printed directly on the insulated conductors.
Inner covering No inner covering. (Additional tapes may be applied)
Armour/screen No armour.
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
"meter" "r" DRAKA NORSK KABEL BU(c) 250V S14 8 PAIR 0,75 mm2 FLEX -
Marking text
FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22
Outer sheath Grey or Blue
colour

Core identification instrumentation cables


Pair Black - Light Blue
Triple Black - Light Blue - Brown
Quad Black - Light Blue - Brown - Grey

www.drakaMOG.com
242
BU(c) 250V(3).doc
29.12.2006 10:20
Page 2 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured


Range and dimensions
Weight of Copper
No of Cross Conductor Insulation Thickness Diameter
Number of Cable content
cores in section Diameter, Thickness, Outer Sheath, outer sheath,
elements Approx. Approx.
element core, mm mm mm mm mm
(Kg/Km) (kg/km)
2 2 0.75 1.1 0.6 1.1 10.5 0.8 155 33
4 2 0.75 1.1 0.6 1.2 12.5 0.8 235 61
8 2 0.75 1.1 0.6 1.4 17.5 0.8 450 116
12 2 0.75 1.1 0.6 1.5 19.5 0.8 590 172
16 2 0.75 1.1 0.6 1.6 21.5 1 740 228
19 2 0.75 1.1 0.6 1.7 23 1 850 269
24 2 0.75 1.1 0.6 1.8 26.5 1 1060 339
2 3 0.75 1.1 0.6 1.2 12 0.8 205 47
4 3 0.75 1.1 0.6 1.3 14.5 0.8 320 89
8 3 0.75 1.1 0.6 1.5 19.5 0.8 590 173
12 3 0.75 1.1 0.6 1.6 22.5 1 800 257
16 3 0.75 1.1 0.6 1.7 24.5 1 1030 341
24 3 0.75 1.1 0.6 2 30.5 1.5 1500 509
2 2 1.5 1.6 0.7 1.2 13 0.8 230 63
4 2 1.5 1.6 0.7 1.3 15.5 0.8 360 118
8 2 1.5 1.6 0.7 1.5 21 1 680 229
12 2 1.5 1.6 0.7 1.7 24.5 1 940 340
16 2 1.5 1.6 0.7 1.8 26.5 1 1200 451
24 2 1.5 1.6 0.7 2.1 33 1.5 1770 673
2 3 1.5 1.6 0.7 1.3 15 0.8 310 91
4 3 1.5 1.6 0.7 1.4 17.5 0.8 500 174
8 3 1.5 1.6 0.7 1.6 23.5 1 930 341
12 3 1.5 1.6 0.7 1.8 28 1 1310 509
16 3 1.5 1.6 0.7 1.9 30.5 1.5 1680 677
24 3 1.5 1.6 0.7 2.2 37.5 1.5 2480 1011

Electrical values instrumentation cables


Capacitance, approx. Inductance, approx, Resistance at 20C, max. L/R ratio,
Type
(nF/km) (mH/km) (Ohm/km) (microH/Ohm)
Unshielded pair 0,75 mm 100 0,67 24,8 14,3
Unshielded triple 0,75 mm 100 0,67 24,8 14,3
Unshielded pair 1,5 mm 110 0,63 12,2 26,6
Unshielded triple 1,5 mm 110 0,63 12,2 26,6
Unshielded pair 2,5 mm 125 0,59 7,56 39,0
Unshielded triple 2,5 mm 125 0,59 7,56 39,0

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
896806 BU(C) 250V 2PAIR 0.75mm S14 GREY - 7021528968064 -
896818 BU(C) 250V 4PAIR 0.75mm S14 GREY - 7021528968187 -
896830 BU(C) 250V 8PAIR 0.75mm S14 GREY - 7021528968309 -
896836 BU(C) 250V 12PAIR 0.75mm S14 GREY - 7021528968361 -
896842 BU(C) 250V 16PAIR 0.75mm S14 GREY - 7021528968422 -
896845 BU(C) 250V 19PAIR 0.75mm S14 GREY - 7021528968453 -
896848 BU(C) 250V 24PAIR 0.75mm S14 GREY - 7021528968484 -

www.drakaMOG.com
243
BU(c) 250V(3).doc
29.12.2006 10:20
Page 3 of 3

BU(c) 250V S14 Instrumentation cable, Unarmoured


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
896866 BU(C) 250V 2TRIP 0.75mm S14 GREY - 7021528968668 -
896878 BU(C) 250V 4TRIP 0.75mm S14 GREY - 7021528968781 -
896890 BU(C) 250V 8TRIP 0.75mm S14 GREY - 7021528968903 -
896896 BU(C) 250V 12TRIP 0.75mm S14 GREY - 7021528968965 -
896902 BU(C) 250V 16TRIP 0.75mm S14 GREY - 7021528969023 -
896908 BU(C) 250V 24TRIP 0.75mm S14 GREY - 7021528969085 -
897006 BU(C) 250V 2PAIR 1.5mm S14 GREY - 7021528970067 -
897018 BU(C) 250V 4PAIR 1.5mm S14 GREY - 7021528970180 -
897030 BU(C) 250V 8PAIR 1.5mm S14 GREY - 7021528970302 -
897036 BU(C) 250V 12PAIR 1.5mm S14 GREY - 7021528970364 -
897042 BU(C) 250V 16PAIR 1.5mm S14 GREY - 7021528970425 -
897048 BU(C) 250V 24PAIR 1.5mm S14 GREY - 7021528970487 -
897066 BU(C) 250V 2TRIP 1.5mm S14 GREY - 7021528970661 -
897078 BU(C) 250V 4TRIP 1.5mm S14 GREY - 7021528970784 -
897090 BU(C) 250V 8TRIP 1.5mm S14 GREY - 7021528970906 -
897096 BU(C) 250V 12TRIP 1.5mm S14 GREY - 7021528970968 -
897102 BU(C) 250V 16TRIP 1.5mm S14 GREY - 7021528971026 -
897108 BU(C) 250V 24TRIP 1.5mm S14 GREY - 7021528971088 -

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
244
BU(i) 250V(3).doc
29.12.2006 10:26
Page 1 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured


Fire resistant, flame retardant halogen-free
instrumentation cable. Mud resistant

BU(i) 250V
MGT/EPR/EVA

NEK 606 CodeS13

Operating temperature : 90C


Operating Voltage : 250V

Standards applied

Application IEC 60092-376 (2003-05) - Design


IEC 60228 class 2 - Conductor
Fixed installation for instrumentation, communication, control IEC 60092-351 - Insulation
and alarm systems in both EX-(Zone 2) and safe areas, IEC 60092-359 - Sheath
emergency and critical systems where requirement for fire IEC 60332-1 - Flame Retardant
resistance exists. Meets the mud resistant requirements in IEC 60332-3-22 - Flame Retardant
NEK 606. IEC 60331-21 - Fire Resistant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation B Mica-tape + EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
Pair / Triple /
polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
Quad twisting
are identified by numbered tape or by numbers printed directly on the insulated
conductors.
Lay up / Individually shielded pairs/triples/quads are laid up in concentric layers and wrapped
Shielding with a PETP tape.
Inner covering No inner covering. (Additional tapes may be applied)
Armour/screen No armour.
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
"meter" "r" DRAKA NORSK KABEL BU(i) 250V S13 8 PAIR 0,75 mm2 FLEX -
Marking text
FLAME IEC 60092-376 IEC 60331-21 IEC 60332-3-22
Outer sheath Grey or Blue
colour

www.drakaMOG.com
245
BU(i) 250V(3).doc
29.12.2006 10:26
Page 2 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured


Core identification instrumentation cables
Pair Black - Light Blue
Triple Black - Light Blue - Brown
Quad Black - Light Blue - Brown - Grey

Range and dimensions


Weight of Copper
No of Cross Conductor Insulation Thickness Diameter
Number of Cable content
cores in section Diameter, Thickness, Outer Sheath, outer sheath,
elements Approx. Approx.
element core, mm mm mm mm mm
(Kg/Km) (kg/km)
1 2 0.75 1.1 0.6 1 7.5 0.5 95 18.5
1 2 0.75 1.1 0.6 1 7.5 0.5 95 18.5
2 2 0.75 1.1 0.6 1.2 11 0.8 170 37
2 2 0.75 1.1 0.6 1.2 11 0.8 170 37
4 2 0.75 1.1 0.6 1.2 13 0.8 265 74
8 2 0.75 1.1 0.6 1.4 17.5 0.8 510 147
12 2 0.75 1.1 0.6 1.6 21 1 720 220
16 2 0.75 1.1 0.6 1.7 23.5 1 920 293
24 2 0.75 1.1 0.6 1.9 29 1 1340 440
1 3 0.75 1.1 0.6 1 7.5 0.5 110 26
2 3 0.75 1.1 0.6 1.2 12 0.8 205 51
4 3 0.75 1.1 0.6 1.3 14 0.8 350 102
8 3 0.75 1.1 0.6 1.5 19.5 0.8 650 203
12 3 0.75 1.1 0.6 1.7 23.5 1 930 305
16 3 0.75 1.1 0.6 1.8 26 1 1210 407
24 3 0.75 1.1 0.6 2.1 32.5 1.5 1770 610
1 2 1.5 1.6 0.7 1 8.5 0.5 135 35
1 2 1.5 1.6 0.7 1 8.5 0.5 135 35
2 2 1.5 1.6 0.7 1.3 13.5 0.8 250 69
2 2 1.5 1.6 0.7 1.3 13.5 0.8 250 69
4 2 1.5 1.6 0.7 1.4 16 0.8 420 138
8 2 1.5 1.6 0.7 1.6 22 1 790 275
12 2 1.5 1.6 0.7 1.7 26 1 1100 412
12 2 1.5 1.6 0.7 1.7 26 1 1100 412
16 2 1.5 1.6 0.7 1.9 29.5 1 1460 549
24 2 1.5 1.6 0.7 2.2 36.5 1.5 2160 824
1 3 1.5 1.6 0.7 1.1 9.5 0.5 165 49
1 3 1.5 1.6 0.7 1.1 9.5 0.5 165 49
2 3 1.5 1.6 0.7 1.3 14.5 0.8 320 97
4 3 1.5 1.6 0.7 1.4 17.5 0.8 540 194
8 3 1.5 1.6 0.7 1.7 23.5 1 1030 387
12 3 1.5 1.6 0.7 1.9 29 1 1480 582
16 3 1.5 1.6 0.7 2 32.5 1.5 1920 775
24 3 1.5 1.6 0.7 2.4 40.5 2 2880 1163
1 2 2.5 2 0.7 1.1 9.5 0.5 170 54

Electrical values instrumentation cables


Capacitance, approx. Inductance, approx, Resistance at 20C, max. L/R ratio,
Type
(nF/km) (mH/km) (Ohm/km) (microH/Ohm)
Shielded pair 0,75 mm 110 0,67 24,8 14,3
Shielded triple 0,75 mm 110 0,67 24,8 14,3
Shielded pair 1,5 mm 125 0,63 12,2 26,6

www.drakaMOG.com
246
BU(i) 250V(3).doc
29.12.2006 10:26
Page 3 of 3

BU(i) 250V S13 Instrumentation cable, Unarmoured


Capacitance, approx. Inductance, approx, Resistance at 20C, max. L/R ratio,
Type
(nF/km) (mH/km) (Ohm/km) (microH/Ohm)
Shielded triple 1,5 mm 125 0,63 12,2 26,6
Shielded pair 2,5 mm 145 0,59 7,56 39,0
Shielded triple 2,5 mm 145 0,59 7,56 39,0

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
896200 BU(I) 250V 1PAIR 0.75mm S13 GREY - 7021528962000 -
896201 BU(I) 250V 1PAIR 0.75mm S13 BLUE - 7021528962017 -
896206 BU(I) 250V 2PAIR 0.75mm S13 GREY - 7021528962062 -
896207 BU(I) 250V 2PAIR 0.75mm S13 BLUE - 7021528962079 -
896218 BU(I) 250V 4PAIR 0.75mm S13 GREY - 7021528962185 -
896230 BU(I) 250V 8PAIR 0.75mm S13 GREY - 7021528962307 -
896236 BU(I) 250V 12PAIR 0.75mm S13 GREY - 7021528962369 -
896242 BU(I) 250V 16PAIR 0.75mm S13 GREY - 7021528962420 -
896248 BU(I) 250V 24PAIR 0.75mm S13 GREY - 7021528962482 -
896260 BU(I) 250V 1TRIP 0.75mm S13 GREY - 7021528962604 -
896266 BU(I) 250V 2TRIP 0.75mm S13 GREY - 7021528962666 -
896278 BU(I) 250V 4TRIP 0.75mm S13 GREY - 7021528962789 -
896290 BU(I) 250V 8TRIP 0.75mm S13 GREY - 7021528962901 -
896296 BU(I) 250V 12TRIP 0.75mm S13 GREY - 7021528962963 -
896302 BU(I) 250V 16TRIP 0.75mm S13 GREY - 7021528963021 -
896308 BU(I) 250V 24TRIP 0.75mm S13 GREY - 7021528963083 -
896400 BU(I) 250V 1PAIR 1.5mm S13 GREY - 7021528964004 -
896401 BU(I) 250V 1PAIR 1.5mm S13 BLUE - 7021528964011 -
896406 BU(I) 250V 2PAIR 1.5mm S13 GREY - 7021528964066 -
896407 BU(I) 250V 2PAIR 1.5mm S13 BLUE - 7021528964073 -
896418 BU(I) 250V 4PAIR 1.5mm S13 GREY - 7021528964189 -
896430 BU(I) 250V 8PAIR 1.5mm S13 GREY - 7021528964301 -
896436 BU(I) 250V 12PAIR 1.5mm S13 GREY - 7021528964363 -
896437 BU(I) 250V 12PAIR 1.5mm S13 BLUE - 7021528964370 -
896442 BU(I) 250V 16PAIR 1.5mm S13 GREY - 7021528964424 -
896448 BU(I) 250V 24PAIR 1.5mm S13 GREY - 7021528964486 -
896460 BU(I) 250V 1TRIP 1.5mm S13 GREY - 7021528964608 -
896461 BU(I) 250V 1TRIP 1.5mm S13 BLUE - 7021528964615 -
896466 BU(I) 250V 2TRIP 1.5mm S13 GREY - 7021528964660 -
896478 BU(I) 250V 4TRIP 1.5mm S13 GREY - 7021528964783 -
896490 BU(I) 250V 8TRIP 1.5mm S13 GREY - 7021528964905 -
896496 BU(I) 250V 12TRIP 1.5mm S13 GREY - 7021528964967 -
896502 BU(I) 250V 16TRIP 1.5mm S13 GREY - 7021528965025 -
896508 BU(I) 250V 24TRIP 1.5mm S13 GREY - 7021528965087 -
896600 BU(I) 250V 1PAIR 2.5mm S13 GREY - 7021528966008 -

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
247
RFOU 12_20_24kV(3).doc
29.12.2006 11:19
Page 1 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable


Flame retardant halogen-free medium voltage
(MV) cable. Mud resistant

RFOU 12/20(24) kV
EPR/EPR/TCWB/EVA

NEK 606 CodeP19/P21

Operating temperature : 90C


Operating Voltage : 12/20(24) kV

Standards applied

Application IEC 60092-354 - Design


IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for medium voltage (MV) power in both
EX- and safe areas, general purposes. For installation in IEC 60092-359 - Sheath
areas exposed to MUD and drilling/cleaning fluids. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Conductor screen Semiconductive layer (EP-rubber)
semiconductive
Insulation R EP-rubber, IEC 60092-351 (EPR)
Insulation screen Semiconductive layer (EP-rubber)
semicoductive
Cores are laid up together. Cores are identified by White, Black or Red
Lay up / Shielding
threads under and over the metallic screen on each conductor.
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner covering PET tape
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound,
Outer sheath
SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RFOU 12/20(24)KV P19/P21
Marking text
3 x 95/50 mm2 IEC 60332-3-22
Outer sheath colour Red

www.drakaMOG.com
248
RFOU 12_20_24kV(3).doc
29.12.2006 11:19
Page 2 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable


Range and dimensions
Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
1 16 13 5.2 5.5 1.0 22.5 1.0 0.3 1.6 28 1.5 1200 495
29.5
1 25 13 6.5 5.5 1.0 24 1.0 0.3 1.7 1300 561
1.5
1 35 13 7.4 5.5 1.2 25 1.5 0.3 1.8 31 2 1450 671
1 50 15 8.8 5.5 1.2 26.5 1.5 0.3 2.0 32.5 2 1700 811
1 70 13 10.3 5.5 1.2 28 1.5 0.3 2.1 34 2.0 2000 1001
1 95 17 12.1 5.5 1.2 30 1.5 0.3 2.1 36 2 2400 1210
1 120 15 13.6 5.5 1.3 31.5 1.5 0.3 2.1 38 2 2650 1491
1 150 15 15.1 5.5 1.3 33 1.5 0.3 2.2 40 2.5 3000 1835
41.5
1 185 18 16.8 5.5 1.4 35 1.5 0.3 2.2 3500 2201
2.5
45.0
1 240 23 19.1 5.5 1.4 37.5 1.5 0.3 2.4 4350 2915
2.5
47.0
1 300 28 21.5 5.5 1.4 41.0 2.0 0.3 2.6 5200 3640
3.0
55.5
3 16 31 5.2 5.5 1.4 48 2.0 0.4 2.6 9300 4112
3.0
58.5
3 25 35 6.5 5.5 1.4 51 2.0 0.4 2.7 4950 1558
3.0
3 35 35 7.4 5.5 1.4 53 2.0 0.4 2.8 61 3.0 5500 1885
57.0 65.5
3 50 35 8.8 5.5 1.8 0.4 3.0 6500 2276
2.0 3.5
68.5
3 70 35 10.3 5.5 1.8 60 2.5 0.4 3.1 7500 2979
3.5
64.5 73.5
3 95 50 12.1 5.5 2.0 0.5 3.3 9300 4112
3.0 4.0
67.5
3 120 60 13.6 5.5 2.0 0.5 3.4 77 4.0 10250 4761
3.0
71.0 80.0
3 150 75 15.1 5.5 2.0 0.5 3.5 11700 5822
3.0 4.5
75.0 85.0
3 185 45 16.8 5.5 2.0 0.5 3.7 12950 6615
3.5 4.5
79.5 90.0
3 240 55 19.1 5.5 2.2 0.5 3.9 15900 8797
3.5 4.5

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
804100 RFOU 12/20KV 1X 16/13mm P19 RED - 7021528041002 -
804101 RFOU 12/20KV 1X 25/13mm P19 RED - 7021528041019 -
804102 RFOU 12/20KV 1X 35/13mm P19 RED - 7021528041026 -
804103 RFOU 12/20KV 1X 50/15mm P19 RED - 7021528041033 -
804104 RFOU 12/20KV 1X 70/13mm P19 RED - 7021528041040 -
804105 RFOU 12/20KV 1X 95/17mm P19 RED - 7021528041057 -
804106 RFOU 12/20KV 1X120/15mm P19 RED - 7021528041064 -
804107 RFOU 12/20KV 1X150/15mm P19 RED - 7021528041071 -
804108 RFOU 12/20KV 1X185/18mm P19 RED - 7021528041088 -
804109 RFOU 12/20KV 1X240/23mm P19 RED - 7021528041095 -
804110 RFOU 12/20KV 1X300/28mm P19 RED - 7021528041101 -
804120 RFOU 12/20KV 3X 16/31mm P19 RED - 7021528041200 -
804121 RFOU 12/20KV 3X 25/35mm P19 RED - 7021528041217 -

www.drakaMOG.com
249
RFOU 12_20_24kV(3).doc
29.12.2006 11:19
Page 3 of 3

FlexFlame RFOU 12/20(24) kV P19/P21 Power cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
804122 RFOU 12/20KV 3X 35/35mm P19 RED - 7021528041224 -
804123 RFOU 12/20KV 3X 50/35mm P19 RED - 7021528041231 -
804124 RFOU 12/20KV 3X 70/35mm P19 RED - 7021528041248 -
804125 RFOU 12/20KV 3X 95/50mm P19 RED - 7021528041255 -
804126 RFOU 12/20KV 3X120/60mm P19 RED - 7021528041262 -
804127 RFOU 12/20KV 3X150/75mm P19 RED - 7021528041279 -
804128 RFOU 12/20KV 3X185/45mm P19 RED - 7021528041286 -
804129 RFOU 12/20KV 3X240/55mm P19 RED - 7021528041293 -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Capacitans Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, per phase, rating circuit
elements core, screen, resistance resistance Ohm/km Ohm/km nF/km IEC rating 1
mm mm at 20C, at 90C, 60092- second,
Ohm/km Ohm/km 352 Ampere
Table
B.4,
Ampere
1 16 13 STCC 1.16 1.479 0.164 0.197 170 96 2240
1 25 13 STCC 0.734 0.936 0.154 0.185 190 127 3500
1 35 13 STCC 0.529 0.675 0.149 0.178 200 157 4900
1 50 15 STCC 0.391 0.499 0.140 0.169 220 196 7000
1 70 13 STCC 0.270 0.344 0.133 0.160 250 242 9800
1 95 17 STCC 0.195 0.249 0.127 0.152 270 293 13300
1 120 15 STCC 0.154 0.196 0.124 0.149 300 339 16800
1 150 15 STCC 0.126 0.161 0.119 0.142 320 389 21000
1 185 18 STCC 0.100 0.128 0.116 0.139 340 444 25900
1 240 23 STCC 0.0762 0.0972 0.112 0.134 380 522 33600
1 300 28 STCC 0.0607 0.0774 0.108 0.130 410 601 42000
3 16 31 STCC 1.16 1.48 0.143 0.172 170 67 2240
3 25 35 STCC 0.734 0.936 0.133 0.160 190 89 3500
3 35 35 STCC 0.529 0.675 0.128 0.153 200 110 4900
3 50 35 STCC 0.391 0.499 0.121 0.145 220 137 7000
3 70 35 STCC 0.270 0.344 0.115 0.135 250 169 9800
3 95 50 STCC 0.195 0.249 0.109 0.131 270 205 13300
3 120 60 STCC 0.154 0.196 0.105 0.126 300 237 16800
3 150 75 STCC 0.126 0.161 0.102 0.122 320 272 21000
3 185 45 STCC 0.100 0.128 0.099 0.118 340 311 25900
3 240 55 STCC 0.0762 0.0972 0.095 0.114 380 365 33600

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
15 x D 9xD 50 N /mm -20C

www.drakaMOG.com
250
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 1 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Flame retardant halogen-free power
cable. Mud resistant

RFOU 0,6/1kV
EPR/EPR/TCWB/EVA

NEK 606 CodeP1/P8

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Standards applied

Application IEC 60092-353 - Design


IEC 60228 class 2 - Conductor
Fixed installation for power,control and lighting in both EX- and IEC 60092-351 - Insulation
safe areas, general purposes. For installation in areas exposed IEC 60092-359 - Sheath
to MUD and drilling/cleaning fluids. Meets the MUD resistance IEC 60332-1 - Flame Retardant
requirement in NEK 606. IEC 60332-3-22 - Flame Retardant
IEC 60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner PET tape
covering
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound,
Outer sheath
SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 3 x 35/16 mm2 IEC
Marking text
60332-3-22 ETL Classified No. 3067229
Manufacturing unit DRAKA 01 = Draka Norsk Kabel,
Outer sheath colour Black

www.drakaMOG.com
251
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 2 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
1 16 2.5 5.15 1.0 1.1 9.5 0.5 0.2 1.2 13 0.8 360 190
11.5 14.5
1 25 4 6.45 1.2 1.1 0.2 1.2 490 283
0.8 0.8
12.5
1 35 6 7.65 1.2 1.1 0.3 1.3 16 0.8 650 408
0.8
14.5 18.5
1 50 6 9.0 1.4 1.1 0.3 1.4 830 528
0.8 0.8
16.5
1 70 10 10.85 1.4 1.1 0.3 1.4 20.5 1 1100 744
0.8
18.5
1 95 10 12.60 1.6 1.1 0.3 1.5 23 1 1380 961
0.8
1 120 10 14.20 1.6 1.2 20.5 1 0.3 1.6 25 1 1710 1224
1 150 10 15.90 1.8 1.2 22.5 1 0.3 1.6 27 1 2040 1485
1 185 10 17.70 2.0 1.2 24.5 1 0.3 1.7 29.5 1 2480 1837
32.5
1 240 16 20.15 2.2 1.2 27.5 1 0.3 1.8 3130 2372
1.5
30.5 35.5
1 300 16 22.60 2.4 1.2 0.3 1.9 3830 2952
1.5 1.5
12.5
2 1.5 4 1.6 1.0 1.1 9.5 0.5 0.2 1.2 270 80
0.8
13.5
3G 1.5 - 1.6 1.0 1.1 10 0.8 0.2 1.2 295 94
0.8
14.5
4G 1.5 - 1.6 1.0 1.1 11 0.8 0.3 1.3 380 139
0.8
13.5
3 1.5 4 1.6 1.0 1.1 10 0.8 0.2 1.2 295 94
0.8
14.5
4 1.5 6 1.6 1.0 1.1 11 0.8 0.3 1.3 380 139
0.8
15.5
5 1.5 6 1.6 1.0 1.1 12 0.8 0.3 1.3 440 170
0.8
7 1.5 6 1.6 1.0 1.1 13 0.8 0.3 1.3 17 0.8 500 198
17.5
12 1.5 10 1.6 1.0 1.1 0.3 1.5 21.5 1 740 300
0.8
19 1.5 10 1.6 1.0 1.2 20.5 1 0.3 1.6 25 1 1020 413
27 1.5 10 1.6 1.0 1.2 24.5 1 0.3 1.8 29.5 1 1360 551
32.5
37 1.5 16 1.6 1.0 1.2 27.5 1 0.3 1.9 1720 716
1.5
15.5
5G 1.5 - 1.6 1.0 1.1 12 0.8 0.3 1.3 440 170
0.8
7G 1.5 - 1.6 1.0 1.1 13 0.8 0.3 1.3 17 0.8 500 197
2 2.5 4 2.0 1.0 1.1 10.5 0.2 1.2 13.5 320 98
www.drakaMOG.com
252
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 3 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
0.8 0.8
14.5
3G 2.5 - 2.0 1.0 1.1 11 0.8 0.3 1.3 390 152
0.8
14.5
3 2.5 6 2.0 1.0 1.1 11 0.8 0.3 1.3 390 152
0.8
4G 2.5 - 2.0 1.0 1.1 12 0.8 0.3 1.3 16 0.8 460 192
5G 2.5 - 2.0 1.0 1.1 13 0.8 0.3 1.4 17 0.8 530 215
4 2.5 6 2.0 1.0 1.1 12 0.8 0.3 1.3 16 0.8 460 192
5 2.5 6 2.0 1.0 1.1 13 0.8 0.3 1.4 17 0.8 530 215
14.5 18.5
7 2.5 6 2.0 1.0 1.1 0.3 1.4 630 277
0.8 0.8
19.5
12 2.5 10 2.0 1.0 1.2 0.3 1.6 23.5 1 950 424
0.8
19 2.5 10 2.0 1.0 1.2 23 1 0.3 1.7 27.5 1 1310 609
32.5
27 2.5 16 2.0 1.0 1.2 27.5 1 0.3 1.9 1760 817
1.5
31.5 36.5
37 2.5 16 2.0 1.0 1.4 0.3 2 2310 1074
1.5 1.5
13.5
4G 4 - 2.55 1.0 1.1 0.3 1.4 17 0.8 560 247
0.8
14.5 18.5
7G 2.5 - 2.0 1.0 1.1 0.3 1.4 630 276
0.8 0.8
11.5
2 4 6 2.55 1.0 1.1 0.3 1.3 15 0.8 410 157
0.8
3 4 6 2.55 1.0 1.1 12 0.8 0.3 1.3 16 0.8 480 210
13.5
4 4 6 2.55 1.0 1.1 0.3 1.4 17 0.8 560 247
0.8
14.5 18.5
5 4 6 2.55 1.0 1.1 0.3 1.4 660 299
0.8 0.8
3G 4 - 2.55 1.0 1.1 12 0.8 0.3 1.3 16 0.8 480 210
14.5 18.5
5G 4 - 2.55 1.0 1.1 0.3 1.4 660 299
0.8 0.8
12.5 16.5
2 6 6 3.15 1.0 1.1 0.3 1.3 500 209
0.8 0.8
13.5 17.5
3 6 6 3.15 1.0 1.1 0.3 1.4 590 264
0.8 0.8
18.5
4 6 6 3.15 1.0 1.1 15 0.8 0.3 1.4 700 334
0.8
18.5
4G 6 - 3.15 1.0 1.1 15 0.8 0.3 1.4 700 334
0.8
13.5 17.5
3G 6 - 3.15 1.0 1.1 0.3 1.4 590 264
0.8 0.8
16.5
5G 6 - 3.15 1.0 1.1 0.3 1.5 20.5 1 820 388
0.8
14.5 18.5
2 10 10 4.05 1.0 1.1 0.3 1.4 670 299
0.8 0.8
15.5 19.5
3 10 10 4.05 1.0 1.1 0.3 1.4 780 389
0.8 0.8
4 10 10 4.05 1.0 1.1 17 0.8 0.3 1.5 21 1 940 494
15.5 19.5
3G 10 - 4.05 1.0 1.1 0.3 1.4 780 387
0.8 0.8
5G 10 - 4.05 1.0 1.2 19 0.8 0.3 1.5 23 1 1130 600
4G 10 - 4.05 1.0 1.1 17 0.8 0.3 1.5 21 1 940 494
16.5
2 16 16 5.15 1.0 1.1 0.4 1.5 21 1 950 477
0.8
17.5
3 16 16 5.15 1.0 1.1 0.4 1.5 22.5 1 1120 621
0.8
4 16 16 5.15 1.0 1.2 20 1 0.4 1.6 24.5 1 1390 799
www.drakaMOG.com
253
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 4 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
4G 16 - 5.15 1.0 1.2 20 1 0.3 1.6 24 1 1310 727
5G 16 - 5.15 1.0 1.2 22 1 0.3 1.6 26 1 1530 873
17.5
3G 16 - 5.15 1.0 1.1 0.3 1.5 22 1 1050 566
0.8
2 25 16 6.45 1.2 1.2 20.5 1 0.4 1.6 25.5 1 1340 685
3 25 16 6.45 1.2 1.2 22 1 0.3 1.6 26 1 1560 887
4 25 16 6.45 1.2 1.2 24 1 0.3 1.7 28.5 1 1900 1116
4G 25 - 6.45 1.2 1.2 24 1 0.3 1.7 28.5 1 1880 1091
3G 25 - 6.45 1.2 1.2 22 1 0.3 1.6 26 1 1510 837
31.5
5G 25 - 6.45 1.2 1.2 26.5 1 0.3 1.8 2250 1345
1.5
2 35 16 7.65 1.2 1.2 23 1 0.3 1.7 27.5 1 1580 817
3 35 16 7.65 1.2 1.2 24.5 1 0.3 1.7 29 1 1920 1126
31.5
4 35 16 7.65 1.2 1.2 27 1 0.3 1.8 2360 1435
1.5
31.5
4G 35 - 7.65 1.2 1.2 27 1 0.3 1.8 2360 1435
1.5
5G 35 - 7.65 1.2 1.2 30 1.5 0.3 1.9 35 1.5 2840 1768
3 50 25 9.0 1.4 1.2 28.5 1 0.4 1.9 34 1.5 2660 1596
37.5
4 50 25 9.0 1.4 1.4 32 1.5 0.4 2 3290 2025
1.5
4G 50 - 9.0 1.4 1.4 32 1.5 0.3 2 37 1.5 3200 1939
5G 50 - 9.0 1.4 1.4 35 1.5 0.4 2.1 41 2 4000 2498
30.5 36.5
2 70 35 10.85 1.4 1.2 0.6 1.9 3010 1756
1.5 1.5
3 70 35 10.85 1.4 1.4 33 1.5 0.5 2 39 1.5 3690 2346
36.5
4 70 35 10.85 1.4 1.4 0.5 2.2 43 2 4540 2967
1.5
36.5
4G 70 - 10.85 1.4 1.4 0.4 2.2 42.5 2 4410 2839
1.5
5G 70 - 10.85 1.4 1.4 40.5 2 0.4 2.3 46.5 2 5280 3465
5 70 35 10.85 1.4 1.4 40.5 2 0.4 2.3 46.5 2 5360 3547
2 95 50 12.60 1.6 1.4 35 1.5 0.6 2.1 41.5 2 3940 2292
37.5
3 95 50 12.60 1.6 1.4 0.5 2.2 43.5 2 4790 3091
1.5
4 95 50 12.60 1.6 1.4 41.5 2 0.5 2.4 48.5 2 5980 3973
4G 95 - 12.60 1.6 1.4 41.5 2 0.4 2.4 48 2 5750 3749
50.5 58.5
5G 120 - 14.20 1.6 1.6 0.5 2.7 8580 5873
2.5 2.5
2 120 60 14.20 1.6 1.4 38 1.5 0.6 2.2 45 2 4790 2875
3 120 60 14.20 1.6 1.4 41 2 0.6 2.3 48 2 5930 3953
53.5
4 120 60 14.20 1.6 1.6 46 2 0.6 2.5 7410 5071
2.5
52.5
4G 120 - 14.20 1.6 1.6 46 2 0.4 2.5 7090 4754
2.5
58.5
4G 150 - 15.90 1.8 1.6 51 2.5 0.5 2.7 8700 5845
2.5
56.5
4G 185 - 17.7 2.0 1.8 0.5 2.9 64.5 3 10690 7238
2.5
4G 240 - 19.1 2.2 1.8 62 2.5 0.4 2.8 72 3.5 13650 10054
4 185 95 16.8 2.0 1.6 55 2 0.6 2.8 64 3 11350 6598
4 240 120 19.1 2.2 2.0 62 2.5 0.6 3.0 72 3.5 14800 8777

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800000 RFOU 0.6/1kV 1X 16/2.5 P1/P8 BLACK - 7021528000009 -
800001 RFOU 0.6/1kV 1X 25/4mm P1/P8 BLACK - 7021528000016 1044206

www.drakaMOG.com
254
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 5 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800002 RFOU 0.6/1kV 1X 35/6mm P1/P8 BLACK - 7021528000023 1044207
800003 RFOU 0.6/1kV 1X 50/6mm P1/P8 BLACK - 7021528000030 1044208
800004 RFOU 0.6/1kV 1X 70/6mm P1/P8 BLACK - 7021528000047 -
800005 RFOU 0.6/1kV 1X 95/10mm P1/P8 BLACK - 7021528000054 1044210
800006 RFOU 0.6/1kV 1X 120/10 P1/P8 BLACK - 7021528000061 -
800007 RFOU 0.6/1kV 1X 150/10 P1/P8 BLACK - 7021528000078 1044211
800008 RFOU 0.6/1kV 1X 185/10 P1/P8 BLACK - 7021528000085 1044213
800009 RFOU 0.6/1kV 1X 240/16 P1/P8 BLACK - 7021528000092 1044214
800010 RFOU 0.6/1kV 1X 300/16 P1/P8 BLACK Yes 7021528000108 1044215
800015 RFOU 0.6/1kV 2X 1.5/4mm P1/P8 BLACK Yes 7021528000153 1044220
800016 RFOU 0.6/1kV 3G 1.5mm P1/P8 BLACK - 7021528000160 -
800017 RFOU 0.6/1kV 4G 1.5mm P1/P8 BLACK - 7021528000177 -
800018 RFOU 0.6/1kV 3X 1.5/4mm P1/P8 BLACK Yes 7021528000184 1044240
800019 RFOU 0.6/1kV 4X 1.5/6mm P1/P8 BLACK Yes 7021528000191 1044260
800020 RFOU 0.6/1kV 5X 1.5/6mm P1/P8 BLACK - 7021528000207 1044305
800021 RFOU 0.6/1kV 7X 1.5/6mm P1/P8 BLACK Yes 7021528000214 1044307
800022 RFOU 0.6/1kV 12X 1.5/10 P1/P8 BLACK Yes 7021528000221 1044312
800023 RFOU 0.6/1kV 19X 1.5/10 P1/P8 BLACK - 7021528000238 1044319
800024 RFOU 0.6/1kV 27X 1.5/10 P1/P8 BLACK - 7021528000245 1044327
800025 RFOU 0.6/1kV 37X 1.5/16 P1/P8 BLACK - 7021528000252 1044337
800026 RFOU 0.6/1kV 5G 1.5mm P1/P8 BLACK - 7021528000269 -
800028 RFOU 0.6/1kV 7G 1.5mm P1/P8 BLACK - 7021528000283 -
800029 RFOU 0.6/1kV 2X 2.5/4mm P1/P8 BLACK Yes 7021528000290 1044221
800030 RFOU 0.6/1kV 3G 2.5mm P1/P8 BLACK - 7021528000306 -
800032 RFOU 0.6/1kV 3X 2.5/6mm P1/P8 BLACK Yes 7021528000320 1044241
800033 RFOU 0.6/1kV 4G 2.5mm P1/P8 BLACK - 7021528000337 -
800034 RFOU 0.6/1kV 5G 2.5mm P1/P8 BLACK - 7021528000344 -
800035 RFOU 0.6/1kV 4X 2.5/6mm P1/P8 BLACK Yes 7021528000351 1044261
800036 RFOU 0.6/1kV 5X 2.5/6mm P1/P8 BLACK - 7021528000368 1044355
800037 RFOU 0.6/1kV 7X 2.5/6mm P1/P8 BLACK - 7021528000375 1044357
800038 RFOU 0.6/1kV 12X 2.5/10 P1/P8 BLACK - 7021528000382 1044362
800039 RFOU 0.6/1kV 19X 2.5/10 P1/P8 BLACK - 7021528000399 1044369
800040 RFOU 0.6/1kV 27X 2.5/16 P1/P8 BLACK - 7021528000405 1044377
800041 RFOU 0.6/1kV 37X 2.5/16 P1/P8 BLACK - 7021528000412 1044387
800043 RFOU 0.6/1kV 4G 4mm P1/P8 BLACK - 7021528000436 -
800044 RFOU 0.6/1kV 7G 2.5mm P1/P8 BLACK - 7021528000443 -
800045 RFOU 0.6/1kV 2X 4/6mm P1/P8 BLACK Yes 7021528000450 1044222
800046 RFOU 0.6/1kV 3X 4/6mm P1/P8 BLACK Yes 7021528000467 1044242
800047 RFOU 0.6/1kV 4X 4/6mm P1/P8 BLACK - 7021528000474 1044262
800048 RFOU 0.6/1kV 5X 4/6mm P1/P8 BLACK - 7021528000481 -
800049 RFOU 0.6/1kV 3G 4mm P1/P8 BLACK - 7021528000498 -
800050 RFOU 0.6/1kV 5G 4mm P1/P8 BLACK - 7021528000504 -
800051 RFOU 0.6/1kV 2X 6/6mm P1/P8 BLACK Yes 7021528000511 1044223
800052 RFOU 0.6/1kV 3X 6/6mm P1/P8 BLACK Yes 7021528000528 1044243
800053 RFOU 0.6/1kV 4X 6/6mm P1/P8 BLACK - 7021528000535 1044263
800054 RFOU 0.6/1kV 4G 6mm P1/P8 BLACK - 7021528000542 -
800055 RFOU 0.6/1kV 3G 6mm P1/P8 BLACK - 7021528000559 -
800056 RFOU 0.6/1kV 5G 6mm P1/P8 BLACK - 7021528000566 -
800057 RFOU 0.6/1kV 2X 10/10mm P1/P8 BLACK - 7021528000573 1044224
800058 RFOU 0.6/1kV 3X 10/10mm P1/P8 BLACK Yes 7021528000580 1044244
800059 RFOU 0.6/1kV 4X 10/10mm P1/P8 BLACK - 7021528000597 1044264
800060 RFOU 0.6/1kV 3G 10mm P1/P8 BLACK - 7021528000603 -
800061 RFOU 0.6/1kV 5G 10mm P1/P8 BLACK - 7021528000610 -
800062 RFOU 0.6/1kV 4G 10mm P1/P8 BLACK - 7021528000627 -
800063 RFOU 0.6/1kV 2X 16/16mm P1/P8 BLACK - 7021528000634 1044225
800064 RFOU 0.6/1kV 3X 16/16mm P1/P8 BLACK Yes 7021528000641 1044245
800065 RFOU 0.6/1kV 4X 16/16mm P1/P8 BLACK - 7021528000658 1044265
800066 RFOU 0.6/1kV 4G 16mm P1/P8 BLACK - 7021528000665 -
800067 RFOU 0.6/1kV 5G 16mm P1/P8 BLACK - 7021528000672 -
800068 RFOU 0.6/1kV 3G 16mm P1/P8 BLACK - 7021528000689 -
800069 RFOU 0.6/1kV 2X 25/16mm P1/P8 BLACK - 7021528000696 1044226
www.drakaMOG.com
255
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 6 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800070 RFOU 0.6/1kV 3X 25/16mm P1/P8 BLACK Yes 7021528000702 1044246
800071 RFOU 0.6/1kV 4X 25/16mm P1/P8 BLACK Yes 7021528000719 1044266
800072 RFOU 0.6/1kV 4G 25mm P1/P8 BLACK - 7021528000726 -
800073 RFOU 0.6/1kV 3G 25mm P1/P8 BLACK - 7021528000733 -
800074 RFOU 0.6/1kV 5G 25mm P1/P8 BLACK - 7021528000740 -
800075 RFOU 0.6/1kV 2X 35/16mm P1/P8 BLACK - 7021528000757 -
800076 RFOU 0.6/1kV 3X 35/16mm P1/P8 BLACK Yes 7021528000764 1044247
800077 RFOU 0.6/1kV 4X 35/16mm P1/P8 BLACK - 7021528000771 1044267
800078 RFOU 0.6/1kV 4G 35mm P1/P8 BLACK - 7021528000788 -
800079 RFOU 0.6/1kV 5G 35mm P1/P8 BLACK - 7021528000795 -
800082 RFOU 0.6/1kV 3X 50/25mm P1/P8 BLACK Yes 7021528000825 1044248
800083 RFOU 0.6/1kV 4X 50/25mm P1/P8 BLACK Yes 7021528000832 1044268
800084 RFOU 0.6/1kV 4G 50mm P1/P8 BLACK - 7021528000849 -
800085 RFOU 0.6/1kV 5G 50mm P1/P8 BLACK - 7021528000856 -
800087 RFOU 0.6/1kV 2X 70/35mm P1/P8 BLACK - 7021528000870 -
800088 RFOU 0.6/1kV 3X 70/35mm P1/P8 BLACK Yes 7021528000887 1044249
800089 RFOU 0.6/1kV 4X 70/35mm P1/P8 BLACK - 7021528000894 1044269
800090 RFOU 0.6/1kV 4G 70mm P1/P8 BLACK - 7021528000900 -
800091 RFOU 0.6/1kV 5G 70mm P1/P8 BLACK - 7021528000917 -
800092 RFOU 0.6/1kV 5X 70/35mm P1/P8 BLACK - 7021528000924 -
800094 RFOU 0.6/1kV 2X 95/50mm P1/P8 BLACK - 7021528000948 -
800095 RFOU 0.6/1kV 3X 95/50mm P1/P8 BLACK Yes 7021528000955 1044250
800096 RFOU 0.6/1kV 4X 95/50mm P1/P8 BLACK Yes 7021528000962 1044270
800097 RFOU 0.6/1kV 4G 95mm P1/P8 BLACK - 7021528000979 -
800099 RFOU 0.6/1kV 5G 120mm P1/P8 BLACK - 7021528000993 -
800100 RFOU 0.6/1kV 2X 120/60 P1/P8 BLACK - 7021528001006 -
800101 RFOU 0.6/1kV 3X 120/60 P1/P8 BLACK Yes 7021528001013 1044251
800105 RFOU 0.6/1kV 4X 120/60 P1/P8 BLACK - 7021528001051 -
800106 RFOU 0.6/1kV 4G 120mm P1/P8 BLACK - 7021528001068 -
800108 RFOU 0.6/1kV 4G 150mm P1/P8 BLACK - 7021528001082 -
800110 RFOU 0.6/1kV 4G 185mm P1/P8 BLACK - 7021528001105 -
803904 RFOU 0.6/1kV 4G 240mm2 P1/P8 BLACK - 7021528039047 -
803905 RFOU 0.6/1kV 4X 185/95 P1/P8 BLACK - 7021528039054 -
803906 RFOU 0.6/1kV 4X 240/120 P1/P8 BLACK - 7021528039061 -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
1 16 2.5 STCC 1.16 1.48 0.116 0.140 96 2240
1 25 4 STCC 0.734 0.936 0.110 0.132 127 3500
1 35 6 STCC 0.529 0.675 0.106 0.128 157 4900
1 50 6 STCC 0.391 0.499 0.104 0.125 196 7000
1 70 10 STCC 0.27 0.344 0.099 0.119 242 9800
1 95 10 STCC 0.195 0.249 0.097 0.116 293 13300
1 120 10 STCC 0.154 0.196 0.094 0.113 339 16800
1 150 10 STCC 0.126 0.161 0.092 0.111 389 21000
1 185 10 STCC 0.1 0.128 0.091 0.109 444 25900
1 240 16 STCC 0.0762 0.0972 0.089 0.107 522 33600
1 300 16 STCC 0.0607 0.0774 0.087 0.105 601 42000
2 1.5 4 STCC 12.2 15.6 0.110 0.132 20 210
3G 1.5 - STCC 12.2 15.6 0.110 0.132 20 210
4G 1.5 - STCC 12.2 15.6 0.110 0.132 16 210
3 1.5 4 STCC 12.2 15.6 0.110 0.132 16 210
4 1.5 6 STCC 12.2 15.6 0.110 0.132 16 210
5 1.5 6 STCC 12.2 15.6 0.110 0.132 13.5 210
7 1.5 6 STCC 12.2 15.6 0.110 0.132 12 210
12 1.5 10 STCC 12.2 15.6 0.110 0.132 10 210

www.drakaMOG.com
256
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 7 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
19 1.5 10 STCC 12.2 15.6 0.110 0.132 8.5 210
27 1.5 10 STCC 12.2 15.6 0.110 0.132 7.5 210
37 1.5 16 STCC 12.2 15.6 0.110 0.132 7 210
5G 1.5 - STCC 12.2 15.6 0.110 0.132 16 210
7G 1.5 - STCC 12.2 15.6 0.110 0.132 12.5 210
2 2.5 4 STCC 7.56 9.64 0.103 0.123 26 350
3G 2.5 - STCC 7.56 9.64 0.103 0.123 26 350
3 2.5 6 STCC 7.56 9.64 0.103 0.123 21 350
4G 2.5 - STCC 7.56 9.64 0.103 0.123 21 350
5G 2.5 - STCC 7.56 9.64 0.103 0.123 21 350
4 2.5 6 STCC 7.56 9.64 0.103 0.123 21 350
5 2.5 6 STCC 7.56 9.64 0.103 0.123 17.5 350
7 2.5 6 STCC 7.56 9.64 0.103 0.123 15.5 350
12 2.5 10 STCC 7.56 9.64 0.103 0.123 13 350
19 2.5 10 STCC 7.56 9.64 0.103 0.123 11 350
27 2.5 16 STCC 7.56 9.64 0.103 0.123 10 350
37 2.5 16 STCC 7.56 9.64 0.103 0.123 9 350
4G 4 - STCC 4.7 5.99 0.096 0.115 28 560
7G 2.5 - STCC 7.56 9.64 0.103 0.123 16.5 350
2 4 6 STCC 4.7 5.99 0.096 0.115 34 560
3 4 6 STCC 4.7 5.99 0.096 0.115 28 560
4 4 6 STCC 4.7 5.99 0.096 0.115 28 560
5 4 6 STCC 4.7 5.99 0.096 0.115 23.5 560
3G 4 - STCC 4.7 5.99 0.096 0.115 34 560
5G 4 - STCC 4.7 5.99 0.096 0.115 28 560
2 6 6 STCC 3.11 3.97 0.090 0.108 44 840
3 6 6 STCC 3.11 3.97 0.090 0.108 36 840
4 6 6 STCC 3.11 3.97 0.090 0.108 36 840
4G 6 - STCC 3.11 3.97 0.090 0.108 36 840
3G 6 - STCC 3.11 3.97 0.090 0.108 44 840
5G 6 - STCC 3.11 3.97 0.090 0.108 36 840
2 10 10 STCC 1.84 2.35 0.084 0.101 61 1400
3 10 10 STCC 1.84 2.35 0.084 0.101 50 1400
4 10 10 STCC 1.84 2.35 0.084 0.101 50 1400
3G 10 - STCC 1.84 2.35 0.084 0.101 61 1400
5G 10 - STCC 1.84 2.35 0.084 0.101 50 1400
4G 10 - STCC 1.84 2.35 0.084 0.101 50 1400
2 16 16 STCC 1.16 1.48 0.080 0.096 80 2240
3 16 16 STCC 1.16 1.48 0.080 0.096 67 2240
4 16 16 STCC 1.16 1.48 0.080 0.096 67 2240
4G 16 - STCC 1.16 1.48 0.080 0.096 67 2240
5G 16 - STCC 1.16 1.48 0.080 0.096 67 2240
3G 16 - STCC 1.16 1.48 0.080 0.096 80 2240
2 25 16 STCC 0.734 0.936 0.079 0.095 108 3500
3 25 16 STCC 0.734 0.936 0.079 0.095 89 3500
4 25 16 STCC 0.734 0.936 0.079 0.095 89 3500
4G 25 - STCC 0.734 0.936 0.079 0.095 89 3500
3G 25 - STCC 0.734 0.936 0.079 0.095 108 3500
5G 25 - STCC 0.734 0.936 0.079 0.095 89 3500
2 35 16 STCC 0.529 0.675 0.076 0.092 133 4900
3 35 16 STCC 0.529 0.675 0.076 0.092 110 4900
4 35 16 STCC 0.529 0.675 0.076 0.092 110 4900
4G 35 - STCC 0.529 0.675 0.076 0.092 110 4900
5G 35 - STCC 0.529 0.675 0.076 0.092 110 4900
3 50 25 STCC 0.391 0.499 0.076 0.092 137 7000
4 50 25 STCC 0.391 0.499 0.076 0.092 137 7000
4G 50 - STCC 0.391 0.499 0.076 0.092 137 7000
www.drakaMOG.com
257
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 8 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
5G 50 - STCC 0.391 0.499 0.076 0.092 137 7000
2 70 35 STCC 0.27 0.344 0.074 0.088 206 9800
3 70 35 STCC 0.27 0.344 0.074 0.088 169 9800
4 70 35 STCC 0.27 0.344 0.074 0.088 169 9800
4G 70 - STCC 0.27 0.344 0.074 0.088 169 9800
5G 70 - STCC 0.27 0.344 0.074 0.088 169 9800
5 70 35 STCC 0.27 0.344 0.074 0.088 141.5 9800
2 95 50 STCC 0.195 0.249 0.073 0.088 249 13300
3 95 50 STCC 0.195 0.249 0.073 0.088 205 13300
4 95 50 STCC 0.195 0.249 0.073 0.088 205 13300
4G 95 - STCC 0.195 0.249 0.073 0.088 205 13300
5G 120 - STCC 0.154 0.196 0.072 0.086 237 16800
2 120 60 STCC 0.154 0.196 0.072 0.086 288 16800
3 120 60 STCC 0.154 0.196 0.072 0.086 237 16800
4 120 60 STCC 0.154 0.196 0.072 0.086 237 16800
4G 120 - STCC 0.154 0.196 0.072 0.086 237 16800
4G 150 - STCC 0.126 0.161 0.072 0.087 272 21000
4G 185 - STCC 0.1 0.128 0.072 0.086 311 25900
4G 240 - STCC 0.0762 0.0972 0.080 0.095 365 33600
4 185 95 STCC 0.1 0.1275 0.081 0.098 311 25900
4 240 120 STCC 0.0762 0.0972 0.080 0.095 365 33600

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
258
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 9 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Flame retardant halogen-free
power cable. Mud resistant.
Single core cable.

RFOU 0,6/1kV
EPR/EPR/TCWB/EVA

NEK 606 CodeP1/P8

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Standards applied

Application IEC 60092-353/60502-1 - Design


IEC 60228 class 2 - Conductor
Fixed installation for power,control and lighting in both EX- and safe IEC 60092-351 - Insulation
areas, general purposes. For installation in areas exposed to MUD IEC 60092-359 - Sheath
and drilling/cleaning fluids. Meets the MUD resistance requirement IEC 60332-1 - Flame Retardant
in NEK 606. IEC 60332-3-22 - Flame Retardant
IEC 60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner PET tape
covering
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound,
Outer sheath
SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1KV P1/P8 1 x 500/25 mm2 IEC
Marking text
60332-3-22
Manufacturing unit DRAKA 01 = Draka Norsk Kabel,
Outer sheath colour Black

www.drakaMOG.com
259
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 10 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
34.5
1 400 25 26.00 2.4 1.4 0.4 2.1 40.5 2 5060 3936
1.5
37.5
1 500 25 29.0 2.4 1.4 0.4 2.2 44 2 6190 4894
1.5
1 630 25 32.80 2.4 1.4 41.5 2 0.4 2.3 48 2 7620 6167

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800011 RFOU 0.6/1kV 1X 400/25 P1/P8 BLACK - 7021528000115 -
800012 RFOU 0.6/1kV 1X 500/25 P1/P8 BLACK - 7021528000122 -
800013 RFOU 0.6/1kV 1X 630/25 P1/P8 BLACK - 7021528000139 -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
690 dc / 670
1 400 25 STCC 0.0475 0.0606 0.087 0.104 56000
ac
780 dc / 720
1 500 25 STCC 0.0369 0.0471 0.085 0.103 70000
ac
890 dc / 780
1 630 25 STCC 0.0286 0.0365 0.083 0.100 88200
ac

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
260
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 11 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Flame retardant halogen-free
power cable. Mud resistant.
Double braided.

RFOU 0,6/1kV
EPR/EPR/TCWB/EVA

NEK 606 CodeP1/P8

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Standards applied

Application IEC 60092-353 - Design


IEC 60228 class 2 - Conductor
Fixed installation for power,control and lighting in both EX- and safe IEC 60092-351 - Insulation
areas, general purposes. For installation in areas exposed to MUD IEC 60092-359 - Sheath
and drilling/cleaning fluids. Meets the MUD resistance requirement IEC 60332-1 - Flame Retardant
in NEK 606. IEC 60332-3-22 - Flame Retardant
IEC 60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner PET tape + rubberized Polyamide tape
covering
Armour/screen O Two layers of tinned copper wire braid (double braid)
Tape over PET tape + rubberized Polyamide tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound,
Outer sheath
SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA 01 RFOU 0,6/1kV P1/P8 3 x 185/95 mm2 IEC
Marking text
60332-3-22 ETL Classified No. 3067229
Manufacturing unit DRAKA 01 = Draka Norsk Kabel,
Outer sheath colour Black

www.drakaMOG.com
261
RFOU 1kV(4).doc
03/06/2008 08:33:00
Page 12 of 12

FlexFlame RFOU 0,6/1kV P1/P8 Power cable


Core identification power cables
Single core - Black
Two cores - Blue - Brown
Three cores - Brown - Black - Grey
Four cores - Blue - Brown - Black - Grey
Five cores - Blue - Brown - Black - Grey - Black
Seven cores and above - White with black numbers
Two cores + earth (3G) - Yellow/green - Blue - Brown
Three cores + earth (4G) - Yellow/green - Brown - Black - Grey
Four cores + earth (5G) - Yellow/green - Blue - Brown - Black - Grey
G / X in cable description - G = One of the cores are yellow/green - X = no yellow/green core
Core identification - to HD308S2 - and IEC 60446:2007-05

Range and dimensions


Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
50.5 59.5
3 185 95 17.70 2.0 1.6 0.5 2.7 9220 6278
2.5 2.5
3 150 70 15.9 1.8 1.6 45.5 2 0.4 2.6 54 2.5 7390 4904
51.5
4 150 70 15.9 1.8 2 0.4 2.8 60.5 3 9320 6288
2.5
57.5
3 240 120 20.15 2.2 1.8 0.6 3 68 3 11820 8063
2.5

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
800093 RFOU 0.6/1kV 3X 185/95 P1/P8 BLACK - 7021528000931 -
800102 RFOU 0.6/1kV 3X 150/70 P1/P8 BLACK - 7021528001020 1044252
800109 RFOU 0.6/1kV 4X 150/70 P1/P8 BLACK - 7021528001099 -
800112 RFOU 0.6/1kV 3X 240/120 P1/P8 BLACK - 7021528001129 -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, rating IEC circuit
elements core, screen, resistance at resistance at Ohm/km Ohm/km 60092-352 rating 1
mm mm 20C, 90C, Table B.4, second,
Ohm/km Ohm/km Ampere Ampere
3 185 95 STCC 0.1 0.128 0.072 0.086 311 25900
3 150 70 STCC 0.126 0.161 0.072 0.087 272 21000
4 150 70 STCC 0.126 0.161 0.072 0.087 272 21000
3 240 120 STCC 0.0762 0.0972 0.072 0.086 365 33600

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
262
RFOU 6_10_12kV(3).doc
29.12.2006 11:06
Page 1 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable


Flame retardant halogen-free medium
voltage (MV) cable. Mud resistant

RFOU 6/10(12) kV
EPR/EPR/TCWB/EVA

NEK 606 CodeP3/P10

Operating temperature : 90C


Operating Voltage : 6/10(12) kV

Standards applied

Application IEC 60092-354 - Design


IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for medium voltage (MV) power in both EX-
and safe areas, general purposes. For installation in areas IEC 60092-359 - Sheath
exposed to MUD and drilling/cleaning fluids. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Conductor screen Semiconductive layer (EP-rubber)
semiconductive
Insulation R EP-rubber, IEC 60092-351 (EPR)
Insulation screen Semiconductive layer (EP-rubber)
semicoductive
Cores are laid up together. Cores are identified by White, Black or Red
Lay up / Shielding
threads under and over the metallic screen on each conductor.
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner covering PET tape
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound,
Outer sheath
SHF2 (IEC 60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RFOU 6/10(12)KV P3/P10 3
Marking text
x 95/50 mm2 IEC 60332-3-22
Outer sheath colour Red

www.drakaMOG.com
263
RFOU 6_10_12kV(3).doc
29.12.2006 11:06
Page 2 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable


Range and dimensions
Cross Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number Conductor Insulation
section section Inner inner Braid Outer outer of Cable content
of Diameter, Thickness,
core, screen, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements mm mm
mm mm mm mm mm mm mm (Kg/Km) (kg/km)
24.0
1 16 11 5.2 3.4 1.0 18.5 1.0 0.3 1.6 900 420
1,5
25.0
1 25 11 6.5 3.4 1.0 20,0 1.0 0.3 1.7 1100 516
1,5
21.0
1 35 11 7.4 3.4 1.0 0.3 1.7 26.0 1.5 1200 611
1.5
22.0 28.0
1 50 11 8.8 3.4 1.0 0.3 1.9 1450 780
1.0 1.5
30.0
1 70 16 10.3 3.4 1.0 23.5 1.5 0.3 1.9 1700 971
2.0
32.0
1 95 16 12.1 3.4 1.2 25.5 1.5 0.3 2.0 2100 1251
2.0
27.5 34.0
1 120 20 13.6 3.4 1.2 0.3 2.0 2350 1506
1.5 2.0
35.0
1 150 19 15.1 3.4 1.2 28.5 1.5 0.3 2.0 2600 1793
2.0
36.5
1 185 18 16.8 3.4 1.2 30.5 1.5 0.3 2.1 3100 2138
2.0
33.0
1 240 21 19.1 3.4 1.2 0.3 2.1 39.0 2.0 3800 2702
1.5
41.5
1 300 29 21.5 3.4 1.2 35 1.5 0.3 2.2 4600 3395
2.5
45.5
1 400 35 24.5 3.4 1.2 36 1.5 0.4 2.3 5900 4536
2.5
41.5 49.5
1 500 40 27.5 3.4 1.4 0.4 2.5 7350 5782
2.0 2.5
46.5 54.5
1 630 40 32.3 3.4 1.4 0.4 2.7 8750 7016
2.0 3.0
39.0 46.0
3 16 32 5.2 3.4 1.4 0.4 2.4 3300 1145
1.5 2.5
42.0 49.5
3 25 31 6.5 3.4 1.4 0.4 2.4 3800 1465
1.5 2.5
43.5
3 35 35 7.4 3.4 1.4 0.4 2.5 51.5 3.0 4300 1573
2.0
47.0
3 50 31 8.8 3.4 1.6 0.4 2.8 55 3 5000 2124
2.0
50.0
3 70 35 10.3 3.4 1.6 0.4 2.8 58.5 3 6000 2880
2.0
54.0
3 95 50 12.1 3.4 1.6 0.4 2.8 62.5 3.0 7500 3975
2.0
57.5 66.5
3 120 60 13.6 3.4 1.6 0.5 3 8350 4650
2.0 3.0
3 150 75 15.1 3.4 1.6 60 2 0.6 3.2 70.5 3 9800 5634
64.5 74.0
3 185 45 16.8 3.4 1.6 0.5 3.3 11300 6511
2.5 3.5
69.5
3 240 53 19.1 3.4 1.6 0.5 3.5 79.5 3.5 13300 8609
2.5
74.5
3 300 55 21.5 3.4 1.6 0.5 3.7 85.0 4.0 16300 10725
3.0

www.drakaMOG.com
264
RFOU 6_10_12kV(3).doc
29.12.2006 11:06
Page 3 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable


Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
804000 RFOU 6/10KV 1X 16/11mm P3/P RED - 7021528040005 -
804001 RFOU 6/10KV 1X 25/11mm P3/P RED - 7021528040012 -
804002 RFOU 6/10KV 1X 35/11mm P3/P RED - 7021528040029 -
804003 RFOU 6/10KV 1X 50/11mm P3/P RED - 7021528040036 -
804004 RFOU 6/10KV 1X 70/16mm P3/P RED - 7021528040043 -
804005 RFOU 6/10KV 1X 95/16mm P3/P RED - 7021528040050 -
804006 RFOU 6/10KV 1X 120/20mm P3/ RED - 7021528040067 -
804007 RFOU 6/10KV 1X 150/19mm P3/ RED - 7021528040074 -
804008 RFOU 6/10KV 1X185/18mm P3/P10 RED - 7021528040081 -
804009 RFOU 6/10KV 1X 240/21mm P3/ RED - 7021528040098 -
804010 RFOU 6/10KV 1X 300/29mm P3/ RED - 7021528040104 -
804011 RFOU 6/10KV 1X 400/35mm P3/ RED - 7021528040111 -
804012 RFOU 6/10KV 1X 500/40mm P3/ RED - 7021528040128 -
804013 RFOU 6/10KV 1X 630/40mm P3/ RED - 7021528040135 -
804020 RFOU 6/10KV 3X 16/32mm P3/P RED - 7021528040203 -
804021 RFOU 6/10KV 3X 25/31mm P3/P RED - 7021528040210 -
804022 RFOU 6/10KV 3X 35/35mm P3/P RED - 7021528040227 -
804023 RFOU 6/10KV 3X 50/31mm P3/P RED - 7021528040234 -
804024 RFOU 6/10KV 3X 70/35mm P3/P RED - 7021528040241 -
804025 RFOU 6/10KV 3X 95/50mm P3/P RED - 7021528040258 -
804026 RFOU 6/10KV 3X 120/60mm P3/ RED - 7021528040265 -
804027 RFOU 6/10KV 3X 150/75mm P3/ RED - 7021528040272 -
804028 RFOU 6/10KV 3X 185/45mm P3/ RED - 7021528040289 -
804029 RFOU 6/10KV 3X 240/53mm P3/ RED - 7021528040296 -
804030 RFOU 6/10KV 3X 300/55mm P3/ RED - 7021528040302 -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Capacitans Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, per phase, rating circuit
elements core, screen, resistance resistance Ohm/km Ohm/km nF/km IEC rating 1
mm mm at 20C, at 90C, 60092- second,
Ohm/km Ohm/km 352 Ampere
Table
B.4,
Ampere
1 16 11 STCC 1.16 1.48 0.154 0.185 220 96 2240
1 25 11 STCC 0.734 0.936 0.144 0.173 250 127 3500
1 35 11 STCC 0.529 0.675 0.138 0.166 270 157 4900
1 50 11 STCC 0.391 0.499 0.132 0.158 300 196 7000
1 70 16 STCC 0.270 0.344 0.125 0.150 340 242 9800
1 95 16 STCC 0.195 0.249 0.119 0.142 380 293 13300
1 120 20 STCC 0.154 0.196 0.116 0.139 410 339 16800
1 150 19 STCC 0.126 0.161 0.111 0.133 450 389 21000
1 185 18 STCC 0.100 0.128 0.108 0.130 480 444 25900
1 240 21 STCC 0.0762 0.0972 0.104 0.125 540 522 33600
1 300 29 STCC 0.0607 0.0774 0.104 0.124 590 601 42000
690 dc /
1 400 35 STCC 0.0475 0.0606 0.090 0.118 660 56000
670 ac
780 dc /
1 500 40 STCC 0.0369 0.0471 0.097 0.117 720 70000
720 ac
890 dc /
1 630 40 STCC 0.0286 0.0365 0.092 0.110 840 88200
780 ac
www.drakaMOG.com
265
RFOU 6_10_12kV(3).doc
29.12.2006 11:06
Page 4 of 4

FlexFlame RFOU 6/10(12) kV P3/P10 Power Cable


Number Cross Cross Conductor Max. Max. Reactance Reactance Capacitans Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, per phase, rating circuit
elements core, screen, resistance resistance Ohm/km Ohm/km nF/km IEC rating 1
mm mm at 20C, at 90C, 60092- second,
Ohm/km Ohm/km 352 Ampere
Table
B.4,
Ampere
3 16 32 STCC 1.16 1.48 0.119 0.143 220 67 2240
3 25 31 STCC 0.734 0.936 0.119 0.143 250 89 3500
3 35 35 STCC 0.529 0.675 0.114 0.137 270 110 4900
3 50 31 STCC 0.391 0.499 0.108 0.130 300 137 7000
3 70 35 STCC 0.270 0.344 0.103 0.124 340 169 9800
3 95 50 STCC 0.195 0.249 0.098 0.118 380 205 13300
3 120 60 STCC 0.154 0.196 0.095 0.114 410 237 16800
3 150 75 STCC 0.126 0.161 0.092 0.111 450 272 21000
3 185 45 STCC 0.100 0.128 0.092 0.111 480 311 25900
3 240 53 STCC 0.0762 0.0972 0.087 0.104 540 365 33600
3 300 55 STCC 0.0607 0.0774 0.084 0.101 590 421 42000

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
15 x D 9xD 50 N /mm -20C

www.drakaMOG.com
266
RFOU(C) 250V(3).doc
03/06/2008 15:29:00
Page 1 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable


Flame retardant halogen-free
instrumentation cable. Mud resistant

RFOU(c) 250V
EPR/EPR/TCWB/EVA

NEK 606 CodeS2/S6

Operating temperature : 90C


Operating Voltage : 250V

Standards applied

Application IEC 60092-376 (2003-05) - Design


IEC 60228 class 2 - Conductor
Fixed installation for instrumentation, communication, Control IEC 60092-351 - Insulation
and alarm systems in both EX- and safe areas. Meets the mud IEC 60092-359 - Sheath
resistant requirements in NEK 606. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
Pair / Triple / are laid up collectively and screened by copper backed polyester tape with tinned
Quad twisting copper drain wire. Pairs/triples are identified by numbers printed directly on the
insulated conductors.
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner PET tape
covering
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
E.g. "meter" "year" DRAKA 01 RFOU(c) 250V S2/S6 8 PAIR 0,75 mm2 IEC
Marking text
60092-376 IEC 60332-3-22 ETL Classified No. 3067229
Manufacturing DRAKA 01 = Draka Norsk Kabel,
unit
Outer sheath Grey or Blue
colour

www.drakaMOG.com
267
RFOU(C) 250V(3).doc
03/06/2008 15:29:00
Page 2 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable


Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey

Range and dimensions


Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number No of Conductor Insulation
section Inner inner Braid Outer outer of Cable content
of cores in Diameter, Thickness,
core, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements element mm mm
mm mm mm mm mm mm (Kg/Km) (kg/km)
2 2 0.75 1.1 0.6 1.1 10 0.8 0.2 1.2 13 0.8 275 82
2 2 0.75 1.1 0.6 1.1 10 0.8 0.2 1.2 13 0.8 275 82
11.5
4 2 0.75 1.1 0.6 1.1 0.3 1.3 15 0.8 390 139
0.8
11.5
4 2 0.75 1.1 0.6 1.1 0.3 1.3 15 0.8 390 139
0.8
8 2 0.75 1.1 0.6 1.1 15 0.8 0.3 1.4 19 0.8 600 223
8 2 0.75 1.1 0.6 1.1 15 0.8 0.3 1.4 19 0.8 600 223
12 2 0.75 1.1 0.6 1.3 18 0.8 0.3 1.5 22 1 790 291
12 2 0.75 1.1 0.6 1.3 18 0.8 0.3 1.5 22 1 790 291
19.5
16 2 0.75 1.1 0.6 1.4 0.3 1.6 23.5 1 950 359
0.8
19.5
16 2 0.75 1.1 0.6 1.4 0.3 1.6 23.5 1 950 359
0.8
19 2 0.75 1.1 0.6 1.4 20.5 1 0.3 1.7 25 1 1090 422
24 2 0.75 1.1 0.6 1.6 24 1 0.3 1.8 28.5 1 1350 511
24 2 0.75 1.1 0.6 1.6 24 1 0.3 1.8 28.5 1 1350 511
14.5
2 3 0.75 1.1 0.6 1.1 11 0.8 0.3 1.3 360 127
0.8
14.5
2 3 0.75 1.1 0.6 1.1 11 0.8 0.3 1.3 360 127
0.8
12.5 16.5
4 3 0.75 1.1 0.6 1.1 0.3 1.3 470 182
0.8 0.8
12.5 16.5
4 3 0.75 1.1 0.6 1.1 0.3 1.3 470 182
0.8 0.8
8 3 0.75 1.1 0.6 1.1 17 0.8 0.3 1.5 21 1 760 292
8 3 0.75 1.1 0.6 1.1 17 0.8 0.3 1.5 21 1 740 292
12 3 0.75 1.1 0.6 1.3 20 1 0.3 1.6 24 1 990 386
12 3 0.75 1.1 0.6 1.3 20 1 0.3 1.6 24 1 990 386
16 3 0.75 1.1 0.6 1.4 21.5 1 0.3 1.7 26 1 1220 488
24 3 0.75 1.1 0.6 1.8 27 1 0.3 2 32 1.5 1790 692
24 3 0.75 1.1 0.6 1.8 27 1 0.3 2 32 1.5 1790 692
15.5
2 2 1.5 1.6 0.7 1.1 12 0.8 0.3 1.3 410 162
0.8
15.5
2 2 1.5 1.6 0.7 1.1 12 0.8 0.3 1.3 410 162
0.8
4 2 1.5 1.6 0.7 1.1 14 0.8 0.3 1.4 18 0.8 560 235
4 2 1.5 1.6 0.7 1.1 14 0.8 0.3 1.4 18 0.8 560 235
5 2 1.5 1.6 0.7 1.1 15 0.8 0.3 1.4 19 0.8 640 263
18.5
8 2 1.5 1.6 0.7 1.1 0.3 1.6 23 1 890 379
0.8
18.5
8 2 1.5 1.6 0.7 1.1 0.3 1.6 23 1 890 379
0.8
10 2 1.5 1.6 0.7 1.2 21 1 0.3 1.7 25.5 1 1070 460
10 2 1.5 1.6 0.7 1.2 21 1 0.3 1.7 25.5 1 1070 460
12 2 1.5 1.6 0.7 1.3 22 1 0.3 1.7 26.5 1 1190 515
16 2 1.5 1.6 0.7 1.4 24 1 0.3 1.8 28.5 1 1480 652
16 2 1.5 1.6 0.7 1.4 24 1 0.3 1.8 28.5 1 1480 652
19 2 1.5 1.6 0.7 1.4 25.5 1 0.3 1.9 30 1.5 1640 736
35.5
24 2 1.5 1.6 0.7 1.8 30 1.5 0.3 2.1 2150 925
1.5
www.drakaMOG.com
268
RFOU(C) 250V(3).doc
03/06/2008 15:29:00
Page 3 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable


Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number No of Conductor Insulation
section Inner inner Braid Outer outer of Cable content
of cores in Diameter, Thickness,
core, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements element mm mm
mm mm mm mm mm mm (Kg/Km) (kg/km)
32 2 1.5 1.6 0.7 1.9 33 1.5 0.4 2.2 39 1.5 2760 1253
32 2 1.5 1.6 0.7 1.9 33 1.5 0.4 2.2 39 1.5 2760 1253
2 3 1.5 1.6 0.7 1.1 13 0.8 0.3 1.4 17 0.8 490 191
15.5 19.5
4 3 1.5 1.6 0.7 1.1 0.3 1.4 670 291
0.8 0.8
8 3 1.5 1.6 0.7 1.1 21 1 0.3 1.7 25.5 1 1130 517
12 3 1.5 1.6 0.7 1.3 24.5 1 0.3 1.8 29 1 1550 711
12 3 1.5 1.6 0.7 1.3 24.5 1 0.3 1.8 29 1 1550 711
31.5
16 3 1.5 1.6 0.7 1.4 26.5 1 0.3 1.9 1930 904
1.5
31.5
16 3 1.5 1.6 0.7 1.4 26.5 1 0.3 1.9 1930 904
1.5
33.5 39.5
24 3 1.5 1.6 0.7 1.8 0.4 2.2 2920 1370
1.5 1.5
33.5 39.5
24 3 1.5 1.6 0.7 1.8 0.4 2.2 2920 1370
1.5 1.5
13.5 17.5
2 2 2.5 2 0.7 1.1 0.3 1.4 490 200
0.8 0.8
19.5
4 2 2.5 2 0.7 1.1 16 0.8 0.3 1.4 680 309
0.8
19.5
4 2 2.5 2 0.7 1.1 16 0.8 0.3 1.4 680 309
0.8
17.5
5 2 2.5 2 0.7 1.1 0.3 1.5 21.5 1 820 371
0.8
12 2 2.5 2 0.7 1.3 25 1 0.3 1.8 30 1.5 1560 758

Electrical values instrumentation cables

Capacitance, approx. Inductance, approx, Resistance at 20C, max. L/R ratio,


Type
(nF/km) (mH/km) (Ohm/km) (microH/Ohm)
Unshielded pair 0,75 mm 100 0,67 26,3 12,7
Unshielded triple 0,75 mm 100 0,67 26,3 12,7
Unshielded pair 1,5 mm 110 0,63 12,2 26,6
Unshielded triple 1,5 mm 110 0,63 12,2 26,6
Unshielded pair 2,5 mm 125 0,59 7,56 39,0
Unshielded triple 2,5 mm 125 0,59 7,56 39,0

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
892606 RFOU(C) 2PAIR 0.75mm S2/S6 GREY Yes 7021528926064 1044421
892607 RFOU(C) 2PAIR 0.75mm S2/S6 BLUE Yes 7021528926071 1044422
892618 RFOU(C) 4PAIR 0.75mm S2/S6 GREY Yes 7021528926187 1044423
892619 RFOU(C) 4PAIR 0.75mm S2/S6 BLUE Yes 7021528926194 1044424
892630 RFOU(C) 8PAIR 0.75mm S2/S6 GREY Yes 7021528926309 1044428
892631 RFOU(C) 8PAIR 0.75mm S2/S6 BLUE Yes 7021528926316 1044429
892636 RFOU(C) 12PAIR 0.75mm S2/S6 GREY Yes 7021528926361 1044430
892637 RFOU(C) 12PAIR 0.75mm S2/S6 BLUE - 7021528926378 1044431
892642 RFOU(C) 16PAIR 0.75mm S2/S6 GREY Yes 7021528926422 1044433
892643 RFOU(C) 16PAIR 0.75mm S2/S6 BLUE Yes 7021528926439 1044432
892645 RFOU(C) 19PAIR 0.75mm S2/S6 GREY - 7021528926453 1044434
892648 RFOU(C) 24PAIR 0.75mm S2/S6 GREY Yes 7021528926484 1044438
892649 RFOU(C) 24PAIR 0.75mm S2/S6 BLUE Yes 7021528926491 1044437

www.drakaMOG.com
269
RFOU(C) 250V(3).doc
03/06/2008 15:29:00
Page 4 of 4

FlexFlame RFOU(c) 250V S2/S6 Instr. cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
892666 RFOU(C) 2TRIP 0.75mm S2/S6 GREY Yes 7021528926668 1044490
892667 RFOU(C) 2TRIP 0.75mm S2/S6 BLUE Yes 7021528926675 1044491
892678 RFOU(C) 4TRIP 0.75mm S2/S6 GREY - 7021528926781 1044492
892679 RFOU(C) 4TRIP 0.75mm S2/S6 BLUE - 7021528926798 1044493
892690 RFOU(C) 8TRIP 0.75mm S2/S6 GREY - 7021528926903 1044496
892691 RFOU(C) 8TRIP 0.75mm S2/S6 BLUE - 7021528926910 1044497
892696 RFOU(C) 12TRIP 0.75mm S2/S6 GREY - 7021528926965 1044499
892697 RFOU(C) 12TRIP 0.75mm S2/S6 BLUE - 7021528926972 1044500
892702 RFOU(C) 16TRIP 0.75mm S2/S6 GREY - 7021528927023 1044501
892708 RFOU(C) 24TRIP 0.75mm S2/S6 GREY - 7021528927085 1044507
892709 RFOU(C) 24TRIP 0.75mm S2/S6 BLUE - 7021528927092 1044508
892806 RFOU(C) 2PAIR 1.5mm S2/S6 GREY Yes 7021528928068 1044461
892807 RFOU(C) 2PAIR 1.5mm S2/S6 BLUE - 7021528928075 1044462
892818 RFOU(C) 4PAIR 1.5mm S2/S6 GREY Yes 7021528928181 1044463
892819 RFOU(C) 4PAIR 1.5mm S2/S6 BLUE - 7021528928198 1044464
892821 RFOU(C) 5PAIR 1.5mm S2/S6 GREY - 7021528928211 -
892830 RFOU(C) 8PAIR 1.5mm S2/S6 GREY Yes 7021528928303 1044468
892831 RFOU(C) 8PAIR 1.5mm S2/S6 BLUE - 7021528928310 1044469
892834 RFOU(C) 10PAIR 1.5mm S2/S6 GREY - 7021528928341 -
892835 RFOU(C) 10PAIR 1.5mm S2/S6 BLUE - 7021528928358 -
892836 RFOU(C) 12PAIR 1.5mm S2/S6 GREY - 7021528928365 1044470
892842 RFOU(C) 16PAIR 1.5mm S2/S6 GREY Yes 7021528928426 1044472
892843 RFOU(C) 16PAIR 1.5mm S2/S6 BLUE - 7021528928433 1044473
892845 RFOU(C) 19PAIR 1.5mm S2/S6 GREY Yes 7021528928457 1044474
892848 RFOU(C) 24PAIR 1.5mm S2/S6 GREY - 7021528928488 1044478
892854 RFOU(C) 32PAIR 1.5mm S2/S6 GREY - 7021528928549 -
892855 RFOU(C) 32PAIR 1.5mm S2/S6 BLUE - 7021528928556 -
892866 RFOU(C) 2TRIP 1.5mm S2/S6 GREY - 7021528928662 1044561
892878 RFOU(C) 4TRIP 1.5mm S2/S6 GREY - 7021528928785 1044563
892891 RFOU(C) 8TRIP 1.5mm S2/S6 BLUE - 7021528928914 1044568
892896 RFOU(C) 12TRIP 1.5mm S2/S6 GREY - 7021528928969 1044569
892897 RFOU(C) 12TRIP 1.5mm S2/S6 BLUE - 7021528928976 1044570
892902 RFOU(C) 16TRIP 1.5mm S2/S6 GREY - 7021528929027 1044571
892903 RFOU(C) 16TRIP 1.5mm S2/S6 BLUE - 7021528929034 1044572
892908 RFOU(C) 24TRIP 1.5mm S2/S6 GREY - 7021528929089 1044577
892909 RFOU(C) 24TRIP 1.5mm S2/S6 BLUE - 7021528929096 1044578
893006 RFOU(C) 2PAIR 2.5mm S2/S6 GREY - 7021528930061 -
893018 RFOU(C) 4PAIR 2.5mm S2/S6 GREY - 7021528930184 -
893019 RFOU(C) 4PAIR 2.5mm S2/S6 BLUE - 7021528930191 -
893021 RFOU(C) 5PAIR 2.5mm S2/S6 GREY - 7021528930214 -
893036 RFOU(C) 12PAIR 2.5mm S2/S6 GREY - 7021528930368 -

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
270
RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 1 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Flame retardant halogen-free
instrumentation cable. Mud
resistant

RFOU(i) 250V
EPR/EPR/TCWB/EVA

NEK 606 CodeS1/S5

Operating temperature : 90C


Operating Voltage : 250V

Standards applied

Application IEC 60092-376 (2003-05) - Design


IEC 60228 class 2 - Conductor
Fixed installation for instrumentation, communication, Control IEC 60092-351 - Insulation
and alarm systems in both EX- and safe areas. Meets the mud IEC 60092-359 - Sheath
resistant requirements in NEK 606. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
Pair / Triple / polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
Quad twisting polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbers printed directly on the insulated conductors.
Lay up / Individually shielded pairs/triples/quads are laid up in concentric layers and
Shielding wrapped with a PETP tape.
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner PET tape
covering
Armour/screen O Tinned annealed copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
E.g. "meter" "year" DRAKA 01 RFOU(i) 250V S1/S5 4 PAIR 0,75 mm2 IEC 60092-
Marking text
376 IEC 60332-3-22 ETL Classified No. 3067229
Manufacturing DRAKA 01 = Draka Norsk Kabel,
unit
Outer sheath Grey or Blue
colour

www.drakaMOG.com
271
RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 2 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Core identification instrumentation cables
Pair - Black - Light Blue
Triple - Black - Light Blue - Brown
Quad - Black - Light Blue - Brown - Grey

Range and dimensions


Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number No of Conductor Insulation
section Inner inner Braid Outer outer of Cable content
of cores in Diameter, Thickness,
core, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements element mm mm
mm mm mm mm mm mm (Kg/Km) (kg/km)
1 2 0.75 1.1 0.6 1.1 7 0.5 0.2 1.1 10 0.8 185 55
1 2 0.75 1.1 0.6 1.1 7 0.5 0.2 1.1 10 0.8 185 55
2 2 0.75 1.1 0.6 1.1 10 0.8 0.2 1.2 13 0.8 280 87
2 2 0.75 1.1 0.6 1.1 10 0.8 0.2 1.2 13 0.8 280 87
11.5
4 2 0.75 1.1 0.6 1.1 0.3 1.3 15 0.8 430 169
0.8
11.5
4 2 0.75 1.1 0.6 1.1 0.3 1.3 15 0.8 430 169
0.8
15.5 19.5
8 2 0.75 1.1 0.6 1.1 0.3 1.5 690 271
0.8 0.8
15.5 19.5
8 2 0.75 1.1 0.6 1.1 0.3 1.5 690 271
0.8 0.8
18.5
12 2 0.75 1.1 0.6 1.3 0.3 1.6 22.5 1 930 356
0.8
18.5
12 2 0.75 1.1 0.6 1.3 0.3 1.6 22.5 1 930 356
0.8
16 2 0.75 1.1 0.6 1.4 20.5 1 0.3 1.7 25 1 1160 449
16 2 0.75 1.1 0.6 1.4 20.5 1 0.3 1.7 25 1 1160 449
19 2 0.75 1.1 0.6 1.4 21.5 1 0.3 1.7 26 1 1280 501
19 2 0.75 1.1 0.6 1.4 21.5 1 0.3 1.7 26 1 1280 501
30.5
24 2 0.75 1.1 0.6 1.6 25.5 1 0.3 1.9 1630 612
1.5
30.5
24 2 0.75 1.1 0.6 1.6 25.5 1 0.3 1.9 1630 612
1.5
10.5
1 3 0.75 1.1 0.6 1.1 7 0.5 0.2 1.1 200 61
0.8
10.5
1 3 0.75 1.1 0.6 1.1 7 0.5 0.2 1.1 200 61
0.8
14.5
2 3 0.75 1.1 0.6 1.1 11 0.8 0.3 1.3 380 148
0.8
14.5
2 3 0.75 1.1 0.6 1.1 11 0.8 0.3 1.3 380 148
0.8
12.5 16.5
4 3 0.75 1.1 0.6 1.1 0.3 1.4 530 211
0.8 0.8
12.5 16.5
4 3 0.75 1.1 0.6 1.1 0.3 1.4 530 211
0.8 0.8
8 3 0.75 1.1 0.6 1.1 17 0.8 0.3 1.6 21.5 1 840 339
8 3 0.75 1.1 0.6 1.1 17 0.8 0.3 1.6 21.5 1 840 339
12 3 0.75 1.1 0.6 1.3 20.5 1 0.3 1.7 25 1 1150 459
12 3 0.75 1.1 0.6 1.3 20.5 1 0.3 1.7 25 1 1150 459
16 3 0.75 1.1 0.6 1.4 23 1 0.3 1.8 28 1 1440 579
16 3 0.75 1.1 0.6 1.4 23 1 0.3 1.8 28 1 1440 579
19 3 0.75 1.1 0.6 1.4 24 1 0.3 1.8 29 1 1600 650
34.5
24 3 0.75 1.1 0.6 1.8 29 1 0.3 2 2110 818
1.5
34.5
24 3 0.75 1.1 0.6 1.8 29 1 0.3 2 2110 818
1.5
1 2 1.5 1.6 0.7 1.1 8 0.5 0.2 1.1 11 0.8 230 72
1 2 1.5 1.6 0.7 1.1 8 0.5 0.2 1.1 11 0.8 230 72
15.5
2 2 1.5 1.6 0.7 1.1 12 0.8 0.3 1.3 420 169
0.8
www.drakaMOG.com
272
RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 3 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Cross Thickness Diameter Diameter Thickness Diameter Weight Copper
Number No of Conductor Insulation
section Inner inner Braid Outer outer of Cable content
of cores in Diameter, Thickness,
core, covering, covering, Wire, Sheath, sheath, Approx. Approx.
elements element mm mm
mm mm mm mm mm mm (Kg/Km) (kg/km)
15.5
2 2 1.5 1.6 0.7 1.1 12 0.8 0.3 1.3 420 169
0.8
4 2 1.5 1.6 0.7 1.1 14 0.8 0.3 1.4 18 0.8 600 254
4 2 1.5 1.6 0.7 1.1 14 0.8 0.3 1.4 18 0.8 600 254
8 2 1.5 1.6 0.7 1.1 19 0.8 0.3 1.6 23.5 1 990 425
8 2 1.5 1.6 0.7 1.1 19 0.8 0.3 1.6 23.5 1 990 425
12 2 1.5 1.6 0.7 1.3 23 1 0.3 1.8 27.5 1 1370 588
12 2 1.5 1.6 0.7 1.3 23 1 0.3 1.8 27.5 1 1370 588
30.5
16 2 1.5 1.6 0.7 1.4 25.5 1 0.3 1.9 1730 750
1.5
30.5
16 2 1.5 1.6 0.7 1.4 25.5 1 0.3 1.9 1730 750
1.5
31.5
19 2 1.5 1.6 0.7 1.4 26.5 1 0.3 1.9 1940 878
1.5
31.5
19 2 1.5 1.6 0.7 1.4 26.5 1 0.3 1.9 1940 878
1.5
24 2 1.5 1.6 0.7 1.8 32 1.5 0.4 2.2 38 1.5 2670 1180
24 2 1.5 1.6 0.7 1.8 32 1.5 0.4 2.2 38 1.5 2670 1180
35.5
32 2 1.5 1.6 0.7 1.9 0.4 2.3 42 2 3320 1500
1.5
35.5
32 2 1.5 1.6 0.7 1.9 0.4 2.3 42 2 3320 1500
1.5
11.5
1 3 1.5 1.6 0.7 1.1 8.5 0.5 0.2 1.1 265 93
0.8
11.5
1 3 1.5 1.6 0.7 1.1 8.5 0.5 0.2 1.1 265 93
0.8
13.5 17.5
2 3 1.5 1.6 0.7 1.1 0.3 1.4 520 214
0.8 0.8
15.5
4 3 1.5 1.6 0.7 1.1 0.3 1.5 20 1 740 328
0.8
15.5
4 3 1.5 1.6 0.7 1.1 0.3 1.5 20 1 740 328
0.8
8 3 1.5 1.6 0.7 1.1 21.5 1 0.3 1.7 26 1 1240 563
8 3 1.5 1.6 0.7 1.1 21.5 1 0.3 1.7 26 1 1240 563
30.5
12 3 1.5 1.6 0.7 1.3 26 1 0.3 1.9 1730 783
1.5
30.5
12 3 1.5 1.6 0.7 1.3 26 1 0.3 1.9 1730 783
1.5
34.5
16 3 1.5 1.6 0.7 1.6 29.5 1 0.3 2 2260 1002
1.5
34.5
16 3 1.5 1.6 0.7 1.6 29.5 1 0.3 2 2260 1002
1.5
36.5
24 3 1.5 1.6 0.7 1.8 0.4 2.3 42.5 2 3380 1566
1.5
36.5
24 3 1.5 1.6 0.7 1.8 0.4 2.3 42.5 2 3380 1566
1.5
1 2 2.5 2 0.7 1.1 9 0.5 0.2 1.1 12 0.8 280 99
13.5 17.5
2 2 2.5 2 0.7 1.1 0.3 1.4 530 225
0.8 0.8
4 2 2.5 2 0.7 1.1 16 0.8 0.3 1.5 20 1 770 350

www.drakaMOG.com
273
RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 4 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Electrical values instrumentation cables
Capacitance, Inductance, Resistance at 20C, L/R ratio,
Type
approx. (nF/km) approx, (mH/km) max. (Ohm/km) (microH/Ohm)
Shielded pair 0,75 mm 110 0,67 26,3 12,7
Shielded triple 0,75 mm 110 0,67 26,3 12,7
Shielded pair 1,5 mm 125 0,63 12,2 26,6
Shielded triple 1,5 mm 125 0,63 12,2 26,6
Shielded pair 2,5 mm 145 0,59 7,56 39,0
Shielded triple 2,5 mm 145 0,59 7,56 39,0

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
892000 RFOU(I) 1PAIR 0.75mm S1/S5 GREY Yes 7021528920000 1044620
892001 RFOU(I) 1PAIR 0.75mm S1/S5 BLUE Yes 7021528920017 1044619
892006 RFOU(I) 2PAIR 0.75mm S1/S5 GREY Yes 7021528920062 1044621
892007 RFOU(I) 2PAIR 0.75mm S1/S5 BLUE - 7021528920079 1044622
892018 RFOU(I) 4PAIR 0.75mm S1/S5 GREY Yes 7021528920185 1044623
892019 RFOU(I) 4PAIR 0.75mm S1/S5 BLUE - 7021528920192 1044624
892030 RFOU(I) 8PAIR 0.75mm S1/S5 GREY Yes 7021528920307 1044628
892031 RFOU(I) 8PAIR 0.75mm S1/S5 BLUE - 7021528920314 1044629
892036 RFOU(I) 12PAIR 0.75mm S1/S5 GREY - 7021528920369 1044630
892037 RFOU(I) 12PAIR 0.75mm S1/S5 BLUE - 7021528920376 1044631
892042 RFOU(I) 16PAIR 0.75mm S1/S5 GREY - 7021528920420 1044633
892043 RFOU(I) 16PAIR 0.75mm S1/S5 BLUE - 7021528920437 1044632
892045 RFOU(I) 19PAIR 0.75mm S1/S5 GREY - 7021528920451 1044634
892046 RFOU(I) 19PAIR 0.75mm S1/S5 BLUE - 7021528920468 1044635
892048 RFOU(I) 24PAIR 0.75mm S1/S5 GREY - 7021528920482 1044636
892049 RFOU(I) 24PAIR 0.75mm S1/S5 BLUE - 7021528920499 1044637
892060 RFOU(I) 1TRIP 0.75mm S1/S5 GREY Yes 7021528920604 1044690
892061 RFOU(I) 1TRIP 0.75mm S1/S5 BLUE Yes 7021528920611 1044689
892066 RFOU(I) 2TRIP 0.75mm S1/S5 GREY - 7021528920666 1044691
892067 RFOU(I) 2TRIP 0.75mm S1/S5 BLUE - 7021528920673 1044692
892078 RFOU(I) 4TRIP 0.75mm S1/S5 GREY - 7021528920789 1044693
892079 RFOU(I) 4TRIP 0.75mm S1/S5 BLUE - 7021528920796 1044694
892090 RFOU(I) 8TRIP 0.75mm S1/S5 GREY - 7021528920901 1044697
892091 RFOU(I) 8TRIP 0.75mm S1/S5 BLUE - 7021528920918 1044698
892096 RFOU(I) 12TRIP 0.75mm S1/S5 GREY - 7021528920963 1044699
892097 RFOU(I) 12TRIP 0.75mm S1/S5 BLUE - 7021528920970 1044700
892102 RFOU(I) 16TRIP 0.75mm S1/S5 GREY - 7021528921021 1044701
892103 RFOU(I) 16TRIP 0.75mm S1/S5 BLUE - 7021528921038 1044702
892106 RFOU(I) 19TRIP 0.75mm S1/S5 GREY - 7021528921069 -
892108 RFOU(I) 24TRIP 0.75mm S1/S5 GREY - 7021528921083 1044707
892109 RFOU(I) 24TRIP 0.75mm S1/S5 BLUE - 7021528921090 1044708
892200 RFOU(I) 1PAIR 1.5mm S1/S5 GREY Yes 7021528922004 1044460
892201 RFOU(I) 1PAIR 1.5mm S1/S5 BLUE - 7021528922011 1044459
892206 RFOU(I) 2PAIR 1.5mm S1/S5 GREY - 7021528922066 1044661
892207 RFOU(I) 2PAIR 1.5mm S1/S5 BLUE - 7021528922073 1044662
892218 RFOU(I) 4PAIR 1.5mm S1/S5 GREY - 7021528922189 1044663
892219 RFOU(I) 4PAIR 1.5mm S1/S5 BLUE - 7021528922196 1044664
892230 RFOU(I) 8PAIR 1.5mm S1/S5 GREY - 7021528922301 1044668
892231 RFOU(I) 8PAIR 1.5mm S1/S5 BLUE - 7021528922318 1044669
892236 RFOU(I) 12PAIR 1.5mm S1/S5 GREY - 7021528922363 1044670
892237 RFOU(I) 12PAIR 1.5mm S1/S5 BLUE - 7021528922370 1044671
892242 RFOU(I) 16PAIR 1.5mm S1/S5 GREY - 7021528922424 1044673
892243 RFOU(I) 16PAIR 1.5mm S1/S5 BLUE - 7021528922431 1044672
892245 RFOU(I) 19PAIR 1.5mm S1/S5 GREY - 7021528922455 1044674
892246 RFOU(I) 19PAIR 1.5mm S1/S5 BLUE - 7021528922462 1044675
892248 RFOU(I) 24PAIR 1.5mm S1/S5 GREY - 7021528922486 1044678
892249 RFOU(I) 24PAIR 1.5mm S1/S5 BLUE - 7021528922493 1044679

www.drakaMOG.com
274
RFOU(I) 250V(3).doc
03/06/2008 10:46:00
Page 5 of 5

FlexFlame RFOU(i) 250V S1/S5 Instr. cable


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
892254 RFOU(I) 32PAIR 1.5mm S1/S5 GREY - 7021528922547 -
892255 RFOU(I) 32PAIR 1.5mm S1/S5 BLUE - 7021528922554 -
892260 RFOU(I) 1TRIP 1.5mm S1/S5 GREY Yes 7021528922608 1044560
892261 RFOU(I) 1TRIP 1.5mm S1/S5 BLUE - 7021528922615 1044559
892266 RFOU(I) 2TRIP 1.5mm S1/S5 GREY - 7021528922660 1044762
892278 RFOU(I) 4TRIP 1.5mm S1/S5 GREY - 7021528922783 1044764
892279 RFOU(I) 4TRIP 1.5mm S1/S5 BLUE - 7021528922790 1044765
892290 RFOU(I) 8TRIP 1.5mm S1/S5 GREY - 7021528922905 1044768
892291 RFOU(I) 8TRIP 1.5mm S1/S5 BLUE - 7021528922912 1044769
892296 RFOU(I) 12TRIP 1.5mm S1/S5 GREY - 7021528922967 1044770
892297 RFOU(I) 12TRIP 1.5mm S1/S5 BLUE - 7021528922974 1044771
892302 RFOU(I) 16TRIP 1.5mm S1/S5 GREY - 7021528923025 1044773
892303 RFOU(I) 16TRIP 1.5mm S1/S5 BLUE - 7021528923032 1044772
892308 RFOU(I) 24TRIP 1.5mm S1/S5 GREY - 7021528923087 1044779
892309 RFOU(I) 24TRIP 1.5mm S1/S5 BLUE - 7021528923094 1044780
892400 RFOU(I) 1PAIR 2.5mm S1/S5 GREY - 7021528924008 -
892406 RFOU(I) 2PAIR 2.5mm S1/S5 GREY - 7021528924060 -
892418 RFOU(I) 4PAIR 2.5mm S1/S5 GREY - 7021528924183 -

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
275
RFOU-HCF-12kv-HF_2006.doc
30.06.2006 08:49
Page 1 of 3

RFOU-HCF 6/10(12)kV P30 / 1100C / 30-60 minutes


HydroCarbon Fire resistant, flame retardant
halogen-free medium voltage power cable.

RFOU-HCF
6/10(12)kV
EPR/EPR/TCWB/EVA/HCF/SHF1

NEK 606 Code P30

1100C / 2000F / 200 kW/m


Operating temperature : 90C
Operating Voltage : 6/10(12)kV

Standards applied

IEC 60092-354 - Design


Draka Norsk Kabel - HCF protection
Application IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for medium voltage (MV) power in both IEC 60092-359 - Sheath
EX- and safe areas, emergency and critical systems IEC 60332-1 - Flame Retardant
where requirement for fire resistance is vital. IEC 60332-3-22 - Flame Retardant
IEC 60331-21 - Fire Resistant
UL 1709 / ASTM E1529 - HC Fire resistance
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code Letter
Conductor Tinned stranded and compressed copper (STCC), IEC 60228 class 2
Conductor screen Semiconductive layer (EP-rubber)
semiconductive
Insulation R EP-rubber, IEC 60092-351 (EPR)
Insulation screen Semiconductive layer (EP-rubber)
semicoductive
Cores are laid up together. Cores are identified by White, Black or Red
Lay up / Shielding
threads under and over the metallic screen on each conductor.
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over PET tape
bedding
Armour/screen O Tinned copper wire braid
Tape over PET tape
armour/screen
U Flame retardant, halogen-free and mud resistant thermoset compound,
Outer sheath
SHF2 (IEC 60092-359)
www.drakaMOG.com
276
RFOU-HCF-12kv-HF_2006.doc
30.06.2006 08:49
Page 2 of 3

RFOU-HCF 6/10(12)kV P30 / 1100C / 30-60 minutes


Code Letter
HCF protection -HCF Extruded heatblock compound
Tape Lapped glassfibre tape
Flame retardant, halogen-free thermoplastic compound, SHF1 (IEC 60092-
Overall sheath
359)
Eg. "meter" "r" DRAKA NORSK KABEL RFOU-HCF 6/10(12)kV P30 1x
Marking text
70/16 mm2 HCF 1100/60 FLEX - FLAME
Outer sheath Red
colour

Range and dimensions


Draka Type Diameter Thickness of Diameter Diameter Weight
Norsk Kabel over bedding armour sheath overall HCF- of cable
part no. [mm2] [mm] wires protection approx.
[mm] [mm] [kg/km]
(mm)

886498 1x 70/16 23,51,5 0,3 30,02,0 62,03,0 5220


1x 95/16 25,51,5 0,3 32,02,0 64,53,0 5900
1x 120/20 27,51,5 0,3 34,02,0 66,53,0 6340
1x 150/19 28,51,5 0,3 35,02,0 67,53,0 6670
1x 185/18 30,51,5 0,3 36,52,0 69,03,0 7320
1x 240/21 33,01,5 0,3 39,02,0 72,03,5 8250
1x 300/29 35,01,5 0,3 41,52,5 74,53,5 9280

3x 50/31 47,02,0 0,4 55,03,0 89,04,5 10970


3x 95/50 54,02,0 0,4 62,53,5 97,05,0 14230
3x 150/75 60,02,5 0,6 70,53,0 106,06,0 17400

Type Diameter of Insulation Semi- Diameter over


copper thickness, conducting insulated, screened
(mm) conductor nominal layer conductor,
approx. mm mm thickness approx. mm
approx. mm

1x 70/16 10,3 3,4 0,8 21,5


1x 95/16 12,1 3,4 0,8 23,0
1x 120/20 13,6 3,4 0,8 24,5
1x 150/19 15,1 3,4 0,8 26,0
1x 185/18 16,8 3,4 0,8 28,0
1x 240/21 19,1 3,4 0,8 30,0
1x 300/29 21.5 3,4 0,8 32,5

3x 50/31 8,8 3,4 0,8 20,0


3x 95/50 12,1 3,4 0,8 23,0
3x 150/75 15,1 3,4 0,8 26,0

www.drakaMOG.com
277
RFOU-HCF-12kv-HF_2006.doc
30.06.2006 08:49
Page 3 of 3

RFOU-HCF 6/10(12)kV P30 / 1100C / 30-60 minutes


ELECTRICAL DATA
No. of cores Conductor resistance Reactance Impedance Continous Short circuit
x cross DC [/km] [/km] at 90 current (conductor)
section [/km] C rating [Ampere]
[mm2] at 20 C at 90 C at 50 Hz at 50 Hz at 45 C 1 sec 0,3 sec

1x 70/16 0,270 0,344 0,172 0,385 242 9800 17892


1x 95/16 0,195 0,249 0,164 0,298 293 13300 24282
1x 120/20 0,154 0,196 0,159 0,253 339 16800 30672
1x 150/19 0,126 0,161 0,153 0,222 389 21000 38340
1x 185/18 0,100 0,128 0,148 0,195 444 25900 47286
1x 240/21 0,0762 0,0972 0,143 0,173 522 33600 61344
1x 300/29 0,0607 0,0774 0,137 0,158 601 42000 76681

3x 50/31 0,391 0,499 0,108 0,261 137 7000 12780


3x 95/50 0,195 0,249 0,098 0,268 205 13300 24282
3x 150/75 0,1126 0,161 0,092 0,185 272 21000 38340

INSTALLATION DATA
TYPE Overall Minimum bending radius Maximum
Diameter During Fixed pulling tension
[mm2] [mm] Installation Installed [N]
[mm]
20 x D 12 x D

1 x70/16 62,03,0 1240 744 3500


1x 95/16 64,53,0 1290 774 4750
1x 120/20 66,53,0 1330 798 6000
1x 150/19 67,53,0 1350 810 7500
1x 185/18 69,03,0 1380 828 9250
1x 240/21 72,03,5 1440 864 12000
1x 300/29 74,53,5 1490 894 15000

3x 50/31 89,04,5 1780 1068 7500


3x 95/50 97,05,0 1940 1164 14250
3x 150/75 106,06,0 2120 1272 20000

Minimum installation temperature: - 10 C

www.drakaMOG.com
278
RU 1kV(3).doc
29.12.2006 10:47
Page 1 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Flame retardant halogen-free power
cable. Mud resistant

RU 0,6/1kV
EPR/EVA

NEK 606 CodeP18

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Standards applied

Application IEC 60092-353 - Design


IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for power,control and lighting in both EX- and
safe areas, general purposes. For installation in areas exposed to IEC 60092-359 - Sheath
MUD and drilling/cleaning fluids. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-351 (EPR)
Lay up / Shielding Cores laid up in concentric layers
Inner covering No inner covering. (Additional tapes may be applied)
Armour/screen No armour.
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2
Outer sheath
(IEC 60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RU 0,6/1KV P18 3 x 2,5 mm2 IEC
Marking text
60332-3-22
Outer sheath Black
colour

www.drakaMOG.com
279
RU 1kV(3).doc
29.12.2006 10:47
Page 2 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Core identification power cables
Single core Grey (Offwhite)
Two cores Grey (Offwhite) - Black
Three cores Grey (Offwhite) - Black - Red
Four cores Grey (Offwhite) - Black - Red - Blue
Five cores Grey (Offwhite) - Black - Red - Blue - Black
Above five cores Black numbers on white base
Separate earth core Yellow/green
G / x in cable description G = one of the core are yellow/green - x = no yellow/green core

From Q3 2007 the core colours on RFOU, BFOU, RU and BU 0,6/1kV will be changed to follow
Cenelec HD 308S2 colours:
Single core Black
Two cores Blue - Brown
Two cores + earth Blue - Brown - Yellow/green
Three cores Brown - Black - Grey
Three cores + earth Brown - Black - Grey - Yellow/green
Four cores Blue - Brown - Black - Grey
Four cores + earth Blue - Brown - Black - Grey - Yellow/green
Five cores Blue - Brown - Black - Grey - Black
Above five cores Black numbers on white base

Range and dimensions


Copper
Cross Thickness Diameter Weight of Cable
Number of Conductor Insulation content
section Outer Sheath, outer sheath, Approx.
elements Diameter, mm Thickness, mm Approx.
core, mm mm mm (Kg/Km)
(kg/km)
1 50 9.0 1.4 1.2 14.5 0.8 600 428
1 70 10.9 1.4 1.3 16.5 0.8 820 620
1 95 12.60 1.6 1.4 19 0.8 1100 836
1 120 14.20 1.6 1.4 20.5 1 1370 1075
1 150 15.90 1.8 1.5 23 1 1690 1336
1 185 17.7 2.0 1.6 25 1 2070 1663
1 240 20.15 2.2 1.7 28.5 1 2690 2173
1 300 22.60 2.4 1.8 31.5 1.5 3360 2751
2 1.5 1.6 1.0 1.1 9.5 0.5 135 28
3G 1.5 1.6 1.0 1.1 10 0.8 160 42
3 1.5 1.6 1.0 1.1 10 0.8 160 42
4G 1.5 1.6 1.0 1.1 11 0.8 190 56
4 1.5 1.6 1.0 1.1 11 0.8 190 56
7G 1.5 1.6 1.0 1.2 13.5 0.8 290 97
5 1.5 1.6 1.0 1.2 12 0.8 240 70
7 1.5 1.6 1.0 1.2 13.5 0.8 290 98
12 1.5 1.6 1.0 1.4 18 0.8 480 167
19 1.5 1.6 1.0 1.5 21 1 700 264
24 1.5 1.6 1.0 1.6 25 1 890 333
2 2.5 2.0 1.0 1.1 10.5 0.8 170 46
3G 2.5 2.0 1.0 1.1 11 0.8 205 69
3 2.5 2.0 1.0 1.1 11 0.8 205 69
4G 2.5 2.0 1.0 1.2 12 0.8 255 92
4 2.5 2.0 1.0 1.2 12 0.8 250 92
5G 2.5 2.0 1.0 1.2 13.5 0.8 320 114

www.drakaMOG.com
280
RU 1kV(3).doc
29.12.2006 10:47
Page 3 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Copper
Cross Thickness Diameter Weight of Cable
Number of Conductor Insulation content
section Outer Sheath, outer sheath, Approx.
elements Diameter, mm Thickness, mm Approx.
core, mm mm mm (Kg/Km)
(kg/km)
7 2.5 2.0 1.0 1.3 14.5 0.8 390 160
2 4 2.55 1.0 1.2 11.5 0.8 225 74
3G 4 2.55 1.0 1.2 12 0.8 275 110
3 4 2.55 1.0 1.2 12 0.8 275 110
4G 4 2.55 1.0 1.2 13.5 0.8 340 147
4 4 2.55 1.0 1.2 13.5 0.8 340 147
5G 4 2.55 1.0 1.3 15 0.8 410 183
2 6 3.15 1.0 1.2 12.5 0.8 290 109
3G 6 3.15 1.0 1.2 13.5 0.8 360 164
3 6 3.15 1.0 1.2 13.5 0.8 380 163
4 6 3.15 1.0 1.3 15 0.8 450 218
5G 6 3.15 1.0 1.3 16.5 0.8 550 272
4G 6 3.15 1.0 1.3 15 0.8 450 218
2 10 4.05 1.0 1.2 14.5 0.8 410 181
3 10 4.05 1.0 1.3 15.5 0.8 520 271
4G 10 4.05 1.0 1.3 17.5 0.8 660 361
5G 10 4.05 1.0 1.4 19 0.8 820 451
3 16 5.15 1.0 1.4 18 0.8 760 434
4 16 5.15 1.0 1.4 20 1 950 579
3G 16 5.15 1.0 1.4 18.5 0.8 770 434
4G 16 5.15 1.0 1.4 20 1 970 578
5G 16 5.15 1.0 1.5 22.5 1 1190 722
4 25 6.45 1.2 1.6 24.5 1 1420 916
4G 25 6.45 1.2 1.6 25 1 1490 917
2 35 7.65 1.2 1.5 23 1 1150 618
4G 35 7.65 1.2 1.7 28 1 1920 1236
5G 35 7.65 1.2 1.8 31 1.5 2340 1544
3 50 9.0 1.4 1.8 29 1 2050 1287
5G 50 9.0 1.4 2 36.5 1.5 3280 2144
3 70 10.85 1.4 2 33.5 1.5 2840 1863
5G 70 10.85 1.4 2.1 42 2 4480 3105

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
831703 RU 0.6/1kV 1X 50mm P18 BLACK - 7021528317039 1061403
831704 RU 0,6/1KV 1X 70 MM2 P18 BLACK - 7021528317046 -
831705 RU 0.6/1kV 1X 95mm P18 BLACK - 7021528317053 -
831706 RU 0.6/1kV 1X 120mm P18 BLACK - 7021528317060 -
831707 RU 0.6/1kV 1X 150mm P18 BLACK - 7021528317077 1061407
831708 RU 0,6/1KV 1X185 MM2 P18 BLACK - 7021528317084 -
831709 RU 0.6/1kV 1X 240mm P18 BLACK - 7021528317091 -
831710 RU 0.6/1kV 1X 300mm P18 BLACK - 7021528317107 -
831715 RU 0.6/1kV 2X 1.5mm P18 BLACK - 7021528317152 -
831716 RU 0.6/1kV 3G 1.5mm P18 BLACK - 7021528317169 -
831718 RU 0.6/1kV 3X 1.5mm P18 BLACK - 7021528317183 -
831719 RU 0.6/1kV 4G 1.5mm P18 BLACK - 7021528317190 -
831721 RU 0.6/1kV 4X 1.5mm P18 BLACK - 7021528317213 -
831723 RU 0.6/1kV 7G 1.5mm P18 BLACK - 7021528317237 -
831724 RU 0.6/1kV 5X 1.5mm P18 BLACK - 7021528317244 -
831725 RU 0.6/1kV 7X 1.5mm P18 BLACK - 7021528317251 -
www.drakaMOG.com
281
RU 1kV(3).doc
29.12.2006 10:47
Page 4 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
831726 RU 0,6/1KV 12X 1,5 MM2 P18 BLACK - 7021528317268 -
831728 RU 0.6/1kV 19X 1.5mm P18 BLACK - 7021528317282 -
831729 RU 0,6/1KV 24X 1,5 MM2 P18 BLACK - 7021528317299 -
831733 RU 0.6/1kV 2X 2.5mm P18 BLACK - 7021528317336 -
831734 RU 0.6/1kV 3G 2.5mm P18 BLACK - 7021528317343 1061434
831736 RU 0.6/1kV 3X 2.5mm P18 BLACK - 7021528317367 -
831737 RU 0.6/1kV 4G 2.5mm P18 BLACK - 7021528317374 1061437
831739 RU 0,6/1KV 4X 2,5 MM2 P18 BLACK - 7021528317398 -
831740 RU 0.6/1kV 5G 2.5mm P18 BLACK - 7021528317404 -
831743 RU 0,6/1KV 7X 2,5 MM2 P18 BLACK - 7021528317435 -
831751 RU 0,6/1KV 2X 4 MM2 P18 BLACK - 7021528317510 -
831752 RU 0.6/1kV 3G 4mm P18 BLACK - 7021528317527 -
831753 RU 0.6/1kV 3X 4mm P18 BLACK - 7021528317534 -
831754 RU 0.6/1kV 4G 4mm P18 BLACK - 7021528317541 -
831755 RU 0,6/1KV 4X 4 MM2 P18 BLACK - 7021528317558 -
831756 RU 0,6/1KV 5G 4mm P18 BLACK - 7021528317565 -
831759 RU 0,6/1KV 2X 6 MM2 P18 BLACK - 7021528317596 -
831760 RU 0.6/1kV 3G 6mm P18 BLACK - 7021528317602 -
831761 RU 0,6/1KV 3X 6MM2 P18 BLACK - 7021528317619 -
831762 RU 0.6/1kV 4X 6mm P18 BLACK - 7021528317626 -
831763 RU 0.6/1kV 5G 6mm P18 BLACK - 7021528317633 -
831764 RU 0.6/1kV 4G 6mm P18 BLACK - 7021528317640 -
831766 RU 0,6/1KV 2X 10 MM2 P18 BLACK - 7021528317664 -
831767 RU 0,6/1KV 3X 10 MM2 P18 BLACK - 7021528317671 -
831769 RU 0.6/1kV 4G 10mm P18 BLACK - 7021528317695 -
831770 RU 0.6/1kV 5G 10mm P18 BLACK - 7021528317701 -
831773 RU 0,6/1KV 3X 16 MM2 P18 BLACK - 7021528317732 -
831774 RU 0,6/1KV 4X 16 MM2 P18 BLACK - 7021528317749 -
831775 RU 0.6/1kV 3G 16mm P18 BLACK - 7021528317756 -
831776 RU 0.6/1kV 4G 16mm P18 BLACK - 7021528317763 -
831777 RU 0.6/1kV 5G 16mm P18 BLACK - 7021528317770 -
831781 RU 0,6/1KV 4X 25 MM2 P18 BLACK - 7021528317817 -
831782 RU 0.6/1kV 4G 25mm P18 BLACK - 7021528317824 -
831785 RU 0,6/1KV 2X 35 MM2 P18 BLACK - 7021528317855 -
831788 RU 0.6/1kV 4G 35mm P18 BLACK - 7021528317886 -
831789 RU 0.6/1kV 5G 35mm P18 BLACK - 7021528317893 -
831792 RU 0,6/1KV 3X 50 MM2 P18 BLACK - 7021528317923 -
831796 RU 0.6/1kV 5G 50mm P18 BLACK - 7021528317961 -
831798 RU 0,6/1KV 3X 70 MM2 P18 BLACK - 7021528317985 -
831799 RU 0.6/1kV 5G 70mm P18 BLACK - 7021528317992 -

Electrical values power cables


Number of Cross Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
elements section resistance at resistance at 50Hz, 60Hz, IEC 60092-352 rating 1
core, mm 20C, Ohm/km 90C, Ohm/km Ohm/km Ohm/km Table B.4, second,
Ampere Ampere
1 50 0.391 0.499 0.089 0.107 196 7000
1 70 0.27 0.344 0.099 0.120 242 9800
1 95 0.195 0.249 0.084 0.101 293 13300
1 120 0.154 0.196 0.082 0.099 339 16800
1 150 0.126 0.161 0.082 0.098 389 21000
1 185 0.1 0.128 0.081 0.098 444 25900
1 240 0.0762 0.0972 0.080 0.096 522 33600
www.drakaMOG.com
282
RU 1kV(3).doc
29.12.2006 10:47
Page 5 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Number of Cross Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
elements section resistance at resistance at 50Hz, 60Hz, IEC 60092-352 rating 1
core, mm 20C, Ohm/km 90C, Ohm/km Ohm/km Ohm/km Table B.4, second,
Ampere Ampere
1 300 0.0607 0.0774 0.080 0.096 601 42000
2 1.5 12.2 15.6 0.110 0.132 20 210
3G 1.5 12.2 15.6 0.110 0.132 20 210
3 1.5 12.2 15.6 0.110 0.132 16 210
4G 1.5 12.2 15.6 0.110 0.132 16 210
4 1.5 12.2 15.6 0.110 0.132 16 210
7G 1.5 12.2 15.6 0.110 0.132 12.5 210
5 1.5 12.2 15.6 0.110 0.132 13.5 210
7 1.5 12.2 15.6 0.110 0.132 12 210
12 1.5 12.2 15.6 0.110 0.132 10 210
19 1.5 12.2 15.6 0.110 0.132 8.5 210
24 1.5 12.2 15.6 0.110 0.132 8 210
2 2.5 7.56 9.64 0.102 0.123 26 350
3G 2.5 7.56 9.64 0.103 0.123 26 350
3 2.5 7.56 9.64 0.103 0.123 21 350
4G 2.5 7.56 9.64 0.103 0.123 21 350
4 2.5 7.56 9.64 0.103 0.123 21 350
5G 2.5 7.56 9.64 0.103 0.123 21 350
7 2.5 7.56 9.64 0.103 0.123 15.5 350
2 4 4.7 5.99 0.096 0.115 34 560
3G 4 4.7 5.99 0.096 0.115 34 560
3 4 4.7 5.99 0.096 0.115 28 560
4G 4 4.7 5.99 0.096 0.115 28 560
4 4 4.7 5.99 0.096 0.115 28 560
5G 4 4.7 5.99 0.096 0.115 28 560
2 6 3.11 3.97 0.090 0.108 44 840
3G 6 3.11 3.97 0.090 0.108 44 840
3 6 3.11 3.97 0.090 0.108 36 840
4 6 3.11 3.97 0.090 0.108 36 840
5G 6 3.11 3.97 0.090 0.108 36 840
4G 6 3.11 3.97 0.090 0.108 36 840
2 10 1.84 2.35 0.084 0.101 61 1400
3 10 1.84 2.35 0.084 0.101 50 1400
4G 10 1.84 2.35 0.084 0.101 50 1400
5G 10 1.84 2.35 0.084 0.101 50 1400
3 16 1.16 1.48 0.080 0.096 67 2240
4 16 1.16 1.48 0.080 0.096 67 2240
3G 16 1.16 1.48 0.080 0.096 80 2240
4G 16 1.16 1.48 0.080 0.096 67 2240
5G 16 1.16 1.48 0.103 0.123 67 2240
4 25 0.734 0.936 0.079 0.095 89 3500
4G 25 0.734 0.936 0.079 0.095 89 3500
2 35 0.529 0.675 0.076 0.092 133 4900
4G 35 0.529 0.675 0.076 0.092 110 4900
5G 35 0.529 0.675 0.076 0.092 110 4900
3 50 0.391 0.499 0.076 0.092 137 7000
5G 50 0.391 0.499 0.076 0.092 137 7000
3 70 0.27 0.344 0.075 0.091 169 9800
5G 70 0.27 0.344 0.076 0.092 169 9800

www.drakaMOG.com
283
RU 1kV(3).doc
29.12.2006 10:47
Page 6 of 6

RU 0,6/1kV P18, Power cable, Unarmoured


Ambient temperature correction factors
Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
284
RU(c) 250V(3).doc
29.12.2006 10:15
Page 1 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured


Flame retardant halogen-free
instrumentation cable. Mud resistant

RU(c) 250V
EPR/EVA

NEK 606 CodeS12

Operating temperature : 90C


Operating Voltage : 250V

Standards applied

Application IEC 60092-376 (2003-05) - Design


IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for instrumentation, communication, Control
and alarm systems in both EX- (Zone 2) and safe areas. IEC 60092-359 - Sheath
Meets the mud resistant requirements in NEK 606. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together and wrapped with polyester tape. Pairs/Triples
Pair / Triple / are laid up collectively and screened by copper backed polyester tape with tinned
Quad twisting copper drain wire. Pairs/triples are identified by numbers printed directly on the
insulated conductors.
Inner covering No inner covering. (Additional tapes may be applied)
Armour/screen No armour.
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RU(c) 250V S12 2 pair 0,75 mm2 IEC
Marking text
60092-376 IEC 60332-3-22
Outer sheath Grey or Blue
colour

Core identification instrumentation cables


Pair Black - Light Blue
Triple Black - Light Blue - Brown
Quad Black - Light Blue - Brown - Grey

www.drakaMOG.com
285
RU(c) 250V(3).doc
29.12.2006 10:15
Page 2 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured


Range and dimensions
Weight of Copper
No of Cross Conductor Insulation Thickness Diameter
Number of Cable content
cores in section Diameter, Thickness, Outer Sheath, outer sheath,
elements Approx. Approx.
element core, mm mm mm mm mm
(Kg/Km) (kg/km)
2 2 0.75 1.1 0.6 1.1 10 0.8 140 33
4 2 0.75 1.1 0.6 1.1 11.5 0.8 200 60
8 2 0.75 1.1 0.6 1.3 16 0.8 410 116
12 2 0.75 1.1 0.6 1.4 18 0.8 530 172
16 2 0.75 1.1 0.6 1.5 19.5 0.8 660 227
19 2 0.75 1.1 0.6 1.5 20.5 1 750 269
24 2 0.75 1.1 0.6 1.7 24 1 950 338
2 3 0.75 1.1 0.6 1.1 11 0.8 170 47
4 3 0.75 1.1 0.6 1.2 13 0.8 270 89
8 3 0.75 1.1 0.6 1.4 17.5 0.8 530 172
16 3 0.75 1.1 0.6 1.6 22 1 900 341
24 3 0.75 1.1 0.6 1.8 27 1 1300 508
2 2 1.5 1.6 0.7 1.2 12 0.8 210 62
4 2 1.5 1.6 0.7 1.2 14 0.8 320 118
8 2 1.5 1.6 0.7 1.4 19.5 0.8 630 229
12 2 1.5 1.6 0.7 1.6 22.5 1 850 339
12 2 1.5 1.6 0.7 1.6 22.5 1 850 339
16 2 1.5 1.6 0.7 1.7 24.5 1 1080 450
24 2 1.5 1.6 0.7 1.9 30 1.5 1550 672
2 3 1.5 1.6 0.7 1.2 13.5 0.8 265 91
4 3 1.5 1.6 0.7 1.3 16 0.8 430 174
8 3 1.5 1.6 0.7 1.5 21.5 1 840 341
12 3 1.5 1.6 0.7 1.7 25.5 1 1170 509
16 3 1.5 1.6 0.7 1.8 27.5 1 1500 676
24 3 1.5 1.6 0.7 2.1 34 1.5 2210 1010

Electrical values instrumentation cables


Capacitance, approx. Inductance, approx, Resistance at 20C, max. L/R ratio,
Type
(nF/km) (mH/km) (Ohm/km) (microH/Ohm)
Unshielded pair 0,75 mm 100 0,67 24,8 14,3
Unshielded triple 0,75 mm 100 0,67 24,8 14,3
Unshielded pair 1,5 mm 110 0,63 12,2 26,6
Unshielded triple 1,5 mm 110 0,63 12,2 26,6
Unshielded pair 2,5 mm 125 0,59 7,56 39,0
Unshielded triple 2,5 mm 125 0,59 7,56 39,0

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
895606 RU(C) 250V 2PAIR 0.75mm S12 GREY - 7021528956061 -
895618 RU(C) 250V 4PAIR 0.75mm S12 GREY - 7021528956184 -
895630 RU(C) 250V 8PAIR 0.75mm S12 GREY - 7021528956306 -
895636 RU(C) 250V 12PAIR 0.75mm S12 GREY - 7021528956368 -
895642 RU(C) 250V 16PAIR 0.75mm S12 GREY - 7021528956429 -
895645 RU(C) 250V 19PAIR 0.75mm S12 GREY - 7021528956450 -
895648 RU(C) 250V 24PAIR 0.75mm S12 GREY - 7021528956481 -
895666 RU(C) 250V 2TRIP 0.75mm S12 GREY - 7021528956665 -

www.drakaMOG.com
286
RU(c) 250V(3).doc
29.12.2006 10:15
Page 3 of 3

RU(c) 250V S12 Instrumentation cable, Unarmoured


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
895678 RU(C) 250V 4TRIP 0.75mm S12 GREY - 7021528956788 -
895690 RU(C) 250V 8TRIP 0.75mm S12 GREY - 7021528956900 -
895702 RU(C) 250V 16TRIP 0.75mm S12 GREY - 7021528957020 -
895708 RU(C) 250V 24TRIP 0.75mm S12 GREY - 7021528957082 -
895806 RU(C) 250V 2PAIR 1.5mm S12 GREY - 7021528958065 -
895818 RU(C) 250V 4PAIR 1.5mm S12 GREY - 7021528958188 -
895830 RU(C) 250V 8PAIR 1.5mm S12 GREY - 7021528958300 -
895836 RU(C) 250V 12PAIR 1.5mm S12 GREY - 7021528958362 -
895837 RU(C) 250V 12PAIR 1.5mm S12 BLUE - 7021528958379 -
895842 RU(C) 250V 16PAIR 1.5mm S12 GREY - 7021528958423 -
895848 RU(C) 250V 24PAIR 1.5mm S12 GREY - 7021528958485 -
895866 RU(C) 250V 2TRIP 1.5mm S12 GREY - 7021528958669 -
895878 RU(C) 250V 4TRIP 1.5mm S12 GREY - 7021528958782 -
895890 RU(C) 250V 8TRIP 1.5mm S12 GREY - 7021528958904 -
895896 RU(C) 250V 12TRIP 1.5mm S12 GREY - 7021528958966 -
895902 RU(C) 250V 16TRIP 1.5mm S12 GREY - 7021528959024 -
895908 RU(C) 250V 24TRIP 1.5mm S12 GREY - 7021528959086 -

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
287
RU(i) 250V(4).doc
29.12.2006 10:09
Page 1 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured


Flame retardant halogen-free instrumentation
cable. Mud resistant

RU(i) 250V
EPR/EVA

NEK 606 CodeS11

Operating temperature : 90C


Operating Voltage : 250V

Standards applied

Application IEC 60092-376 (2003-05) - Design


IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Fixed installation for instrumentation, communication,
Control and alarm systems in both EX- (Zone 2) and safe IEC 60092-359 - Sheath
areas. Meets the mud resistant requirements in NEK 606. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned annealed stranded circular copper (STCC), IEC 60228 class 2
Insulation R EP-rubber, IEC 60092-351 (EPR)
Color coded cores twisted together. Pairs/Triples are screened by copper backed
Pair / Triple / polyester tape with tinned copper drain wire. Each pair/triple is wrapped with
Quad twisting polyester tape to prevent electrical contact with adjacent pairs/triples. Pairs/triples
are identified by numbers printed directly on the insulated conductors.
Lay up / Individually shielded pairs/triples/quads are laid up in concentric layers and
Shielding wrapped with a PETP tape.
Inner covering No inner covering. (Additional tapes may be applied)
Armour/screen No armour.
U Flame retardant, halogen-free and mud resistant thermoset compound, SHF2 (IEC
Outer sheath
60092-359)
E.g. "meter" "year" DRAKA NORSK KABEL RU(i) 250V S11 2 pair 0,75 mm2 IEC
Marking text
60092-376 IEC 60332-3-22
Outer sheath Grey or Blue
colour

Core identification instrumentation cables


Pair Black - Light Blue
Triple Black - Light Blue - Brown
Quad Black - Light Blue - Brown - Grey
www.drakaMOG.com
288
RU(i) 250V(4).doc
29.12.2006 10:09
Page 2 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured


Range and dimensions
Weight of Copper
No of Cross Conductor Insulation Thickness Diameter
Number of Cable content
cores in section Diameter, Thickness, Outer Sheath, outer sheath,
elements Approx. Approx.
element core, mm mm mm mm mm
(Kg/Km) (kg/km)
1 2 0.75 1.1 0.6 1 6.5 0.5 85 18.5
1 2 0.75 1.1 0.6 1 6.5 0.5 85 18.5
2 2 0.75 1.1 0.6 1.1 10 0.8 145 37
2 2 0.75 1.1 0.6 1.1 10 0.8 145 37
4 2 0.75 1.1 0.6 1.2 11.5 0.8 240 74
8 2 0.75 1.1 0.6 1.3 16 0.8 450 147
12 2 0.75 1.1 0.6 1.5 19 0.8 630 220
16 2 0.75 1.1 0.6 1.5 21 1 790 293
24 2 0.75 1.1 0.6 1.7 25.5 1 1160 439
1 3 0.75 1.1 0.6 1 7 0.5 100 26
2 3 0.75 1.1 0.6 1.2 11 0.8 185 51
4 3 0.75 1.1 0.6 1.2 13 0.8 300 102
8 3 0.75 1.1 0.6 1.4 17.5 0.8 580 203
12 3 0.75 1.1 0.6 1.6 21.5 1 810 305
16 3 0.75 1.1 0.6 1.6 23.5 1 1030 406
24 3 0.75 1.1 0.6 1.9 29.5 1 1540 609
1 2 1.5 1.6 0.7 1 8 0.5 120 35
1 2 1.5 1.6 0.7 1 8 0.5 120 35
2 2 1.5 1.6 0.7 1.2 12 0.8 220 69
2 2 1.5 1.6 0.7 1.2 12 0.8 220 69
4 2 1.5 1.6 0.7 1.3 14.5 0.8 370 137
8 2 1.5 1.6 0.7 1.5 19.5 0.8 710 274
12 2 1.5 1.6 0.7 1.6 23.5 1 980 411
16 2 1.5 1.6 0.7 1.7 26.5 1 1270 548
24 2 1.5 1.6 0.7 2 32.5 1.5 1900 822
1 3 1.5 1.6 0.7 1 8.5 0.5 140 49
2 3 1.5 1.6 0.7 1.3 14 0.8 285 97
4 3 1.5 1.6 0.7 1.3 16 0.8 470 194
8 3 1.5 1.6 0.7 1.6 22 1 920 387
16 3 1.5 1.6 0.7 1.9 30 1.5 1710 774
24 3 1.5 1.6 0.7 2.2 37 1.5 2540 1161

Electrical values instrumentation cables


Capacitance, approx. Inductance, approx, Resistance at 20C, max. L/R ratio,
Type
(nF/km) (mH/km) (Ohm/km) (microH/Ohm)
Shielded pair 0,75 mm 110 0,67 24,8 14,3
Shielded triple 0,75 mm 110 0,67 24,8 14,3
Shielded pair 1,5 mm 125 0,63 12,2 26,6
Shielded triple 1,5 mm 125 0,63 12,2 26,6
Shielded pair 2,5 mm 145 0,59 7,56 39,0
Shielded triple 2,5 mm 145 0,59 7,56 39,0

Ordering information
Part number Description Sheath Colour Stock item EAN No. DNK EL No.
895000 RU(I) 250V 1PAIR 0.75mm S11 GREY - 7021528950007 -
895001 RU(I) 250V 1PAIR 0.75mm S11 BLUE - 7021528950014 -
895006 RU(I) 250V 2PAIR 0.75mm S11 GREY - 7021528950069 -
www.drakaMOG.com
289
RU(i) 250V(4).doc
29.12.2006 10:09
Page 3 of 3

RU(i) 250V S11 Instrumentation cable, Unarmoured


Part number Description Sheath Colour Stock item EAN No. DNK EL No.
895007 RU(I) 250V 2PAIR 0.75mm S11 BLUE - 7021528950076 -
895018 RU(I) 250V 4PAIR 0.75mm S11 GREY - 7021528950182 -
895030 RU(I) 250V 8PAIR 0.75mm S11 GREY - 7021528950304 -
895036 RU(I) 250V 12PAIR 0.75mm S11 GREY - 7021528950366 -
895042 RU(I) 250V 16PAIR 0.75mm S11 GREY - 7021528950427 -
895048 RU(I) 250V 24PAIR 0.75mm S11 GREY - 7021528950489 -
895060 RU(I) 250V 1TRIP 0.75mm S11 GREY - 7021528950601 -
895066 RU(I) 250V 2TRIP 0.75mm S11 GREY - 7021528950663 -
895078 RU(I) 250V 4TRIP 0.75mm S11 GREY - 7021528950786 -
895090 RU(I) 250V 8TRIP 0.75mm S11 GREY - 7021528950908 -
895096 RU(I) 250V 12TRIP 0.75mm S11 GREY - 7021528950960 -
895102 RU(I) 250V 16TRIP 0.75mm S11 GREY - 7021528951028 -
895108 RU(I) 250V 24TRIP 0.75mm S11 GREY - 7021528951080 -
895200 RU(I) 250V 1PAIR 1.5mm S11 GREY - 7021528952001 -
895201 RU(I) 250V 1PAIR 1.5mm S11 BLUE - 7021528952018 -
895206 RU(I) 250V 2PAIR 1.5mm S11 GREY - 7021528952063 -
895207 RU(I) 250V 2PAIR 1.5mm S11 BLUE - 7021528952070 -
895218 RU(I) 250V 4PAIR 1.5mm S11 GREY - 7021528952186 -
895230 RU(I) 250V 8PAIR 1.5mm S11 GREY - 7021528952308 -
895236 RU(I) 250V 12PAIR 1.5mm S11 GREY - 7021528952360 -
895242 RU(I) 250V 16PAIR 1.5mm S11 GREY - 7021528952421 -
895248 RU(I) 250V 24PAIR 1.5mm S11 GREY - 7021528952483 -
895260 RU(I) 250V 1TRIP 1.5mm S11 GREY - 7021528952605 -
895266 RU(I) 250V 2TRIP 1.5mm S11 GREY - 7021528952667 -
895278 RU(I) 250V 4TRIP 1.5mm S11 GREY - 7021528952780 -
895290 RU(I) 250V 8TRIP 1.5mm S11 GREY - 7021528952902 -
895302 RU(I) 250V 16TRIP 1.5mm S11 GREY - 7021528953022 -
895308 RU(I) 250V 24TRIP 1.5mm S11 GREY - 7021528953084 -

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
8xD 6xD 50 N /mm -20C

www.drakaMOG.com
290
UX 1000V.doc
26.03.2006 19:12
Page 1 of 2

UX 1000V P15
1 2 3 Flame retardant conductors
UX 1000V
Halogen-free, NEK 606 Type: P15

Maximum operating
Conductor temperature : 90C
Operating voltage : 1000V

Application Standards applied

Insulated conductor for earthing and bonding services. IEC:60092-353 &


Mud resistant in accordance with NEK 606. NEK 606 - Design guidelines
IEC:60332-3-22 - Flame retardance
IEC:60754-1,2 - Halogen-free properties
IEC:61034-1,2 - Smoke density

CONSTRUCTION
CODE LETTER
Conductor Tinned, stranded copper. (1)
PETP-tape. (2)
Insulation U Flame retardant halogen-free thermoset compound. (3)

Unsheathed X

Marking E.g; meter year DRAKA NORSK KABEL UX 1000V P15


1x 95 mm IEC 332-3-22

Colour Yellow/green

www.drakaMOG.com
291
UX 1000V.doc
26.03.2006 19:12
Page 2 of 2

UX 1000V P15
RANGE AND DIMENSIONS: UX 1000V Insulated conductor, P15
Conductor area Conductor Insulation Diameter Weight of Copper content
diameter thickness over conductor approx.
(mm) approx. insulation approx. (kg/km)
(mm) (mm) (mm) (kg/km)

6 3,15 1,0 5,50,8 80 54


10 4,05 1,0 6,50,8 120 87
16 5,15 1,0 7,50,8 180 143
25 6,4 1,2 9,50,8 280 224
35 7,65 1,2 10,51,0 370 310
50 9,00 1,4 12,51,0 520 430
70 10,85 1,4 14,51,0 730 620
95 12,60 1,6 16,51,0 970 840
120 14,20 1,6 18,01,0 1220 1080
150 15,90 1,8 20,01,5 1520 1342
185 17,70 2,0 22,01,5 1890 1670
240 20,15 2,2 25,01,5 2450 2183
300 22,60 2,4 28,01,5 3090 2762

Installation recommendations:
In accordance with IEC 60092-352
Minimum bending radius Maximum pulling tension Minium installation
temperature
During installation Fixed installed
25N x total
cross section of conductors - 20 C
8 x cable diameter 6 x cable diameter

Ordering information:

Conductor area DRAKA NORSK KABEL El-number


(mm) Part number (Norway only)
Yellow/green

6 800800 1045541
10 800801 1045542
16 800802 1045543
25 800803 1045553
35 800804 1045563
50 800805 1045573
70 800806 1045583
95 800807 1045593
120 800808 1045603
150 800809 1045604
185 800810
240 800811
300 800812

www.drakaMOG.com
292
Shipline BI Fire resistant power cable 0.6/1 kV
Halogen free shipcable

BI 0.6/1kV
MGT/XLPE/SHF1

Max. conductor temp. : 90C


Nominal voltage : 0.6/1 kV

Application Standards applied


Design - IEC 60092-353
Unarmoured fire resistant cable for fixed Conductor - IEC 60228 class 2
installations on ships where cable protection is not Insulation - IEC 60092-351
required. For critical power, lighting, control, alarm Sheath - IEC 60092-359
and emergency systems. Fire retardant - IEC 60332-3-22 (cat. A)
Can be installed and operated both indoors and Fire resistant - IEC 60331-21
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector
Conductor
shaped conductors, other types circular conductors

Insulation B Mica glass tape and crosslinked polyethylene, XLPE

Lay up Over the laid up cores one or more tapes may be applied

Inner covering No inner covering

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} BI 0,6/1 kV ..x.. mm2 IEC60331 IEC60332-3-


Marking text
22 ShipLine {year of manufacture} {length indication (meter)}
Outer sheath Green
colour

293
Shipline BI Fire resistant power cable 0.6/1 kV
Halogen free shipcable

Core identification

Single core Black


Two cores Blue - Brown
Three cores Brown - Black - Grey
Four cores Blue - Brown - Black - Grey
Five cores Blue - Brown - Black - Grey - Black
Multi core White with black numbers

with yellow/green (optional)


Two cores + earth (3G) Yellow/green - Blue - Brown
Three cores + earth (4G) Yellow/green - Brown - Black - Grey
Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
2 1.5 - 3.3 0.7 - 1.1 8.5 85 27
2 2.5 - 3.8 0.7 - 1.1 9.5 110 45
3 1.5 - 3.3 0.7 - 1.1 9.5 105 39
3 2.5 - 3.8 0.7 - 1.1 10.0 145 68
3 4 - 4.3 0.7 - 1.2 11.5 205 110
4 1.5 - 3.3 0.7 - 1.1 10.0 135 55
4 6 - 4.8 0.7 - 1.2 14.5 350 227
5 1.5 - 3.3 0.7 - 1.1 11.0 170 70
5 2.5 - 3.8 0.7 - 1.2 12.5 240 127

Electrical values
Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
2 1.5 - 1.83 2.33 0.110 0.132 20 210
2 2.5 - 1.15 1.47 0.103 0.124 26 355
3 1.5 - 0.727 0.927 0.110 0.132 16 210
3 2.5 - 0.524 0.669 0.103 0.124 21 355
3 4 - 0.387 0.494 0.097 0.116 28 570
4 1.5 - 0.268 0.343 0.117 0.141 14 210
4 6 - 0.193 0.248 0.100 0.120 32.5 855
5 1.5 - 0.153 0.198 0.120 0.144 13 210
5 2.5 - 0.124 0.162 0.113 0.136 16.5 210

294
Shipline BI Fire resistant power cable 0.6/1 kV
Halogen free shipcable

Ordering information
Part Description EAN No. Stock
number KDN Item
126458 BI fr 0,6/1kV gn# 2x1,5 mm2 8711401039439 Yes
126461 BI fr 0,6/1kV gn# 2x2,5 mm2 8711401039460 No
126459 BI fr 0,6/1kV gn# 3x1,5 mm2 8711401039446 Yes
126462 BI fr 0,6/1kV gn# 3x2,5 mm2 8711401039477 No
126463 BI fr 0,6/1kV gn# 3x4 mm2 8711401039484 No
126460 BI fr 0,6/1kV gn# 4x1,5 mm2 8711401039453 No
127061 BI fr 0,6/1kV gn# 4x6 mm2 8711401058355 No
128218 BI fr 0,6/1kV gn# 5x1,5 mm2 8711401105233 No
128219 BI fr 0,6/1kV gn# 5x2,5 mm2 8711401105240 No

Ambient temperature correction factors


Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75
Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

295
Shipline BXOI Fire resistant power cable 0.6/1 kV
Halogen free shipcable

BXOI 0.6/1kV
MGT/XLPE/TCWB/SHF1

Max. conductor temp. : 90C


Nominal voltage : 0.6/1 kV

Application Standards applied


Design - IEC 60092-353
Armoured fire resistant cable for fixed installations Conductor - IEC 60228 class 2
on ships where cable protection is required. Insulation - IEC 60092-351
For critical power, lighting, control, alarm and Sheath - IEC 60092-359
emergency systems. Fire retardant - IEC 60332-3-22 (cat. A)
Can be installed and operated both indoors and Fire resistant - IEC 60331-21
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector
Conductor
shaped conductors, other types circular conductors

Insulation B Mica glass tape and crosslinked polyethylene, XLPE

Lay up Over the laid up cores one or more tapes may be applied

Inner covering X No inner covering

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} BXOI 0,6/1 kV ..x../.. mm2 IEC60331-21


Marking text IEC60332-3-22 ShipLine {year of manufacture} {length indication
(meter)}
Outer sheath Green
colour

296
Shipline BXOI Fire resistant power cable 0.6/1 kV
Halogen free shipcable

Core identification

Single core Black


Two cores Blue - Brown
Three cores Brown - Black - Grey
Four cores Blue - Brown - Black - Grey
Five cores Blue - Brown - Black - Grey - Black
Multi core White with black numbers

with yellow/green (optional)


Two cores + earth (3G) Yellow/green - Blue - Brown
Three cores + earth (4G) Yellow/green - Brown - Black - Grey
Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
1 35 4 10.8 0.7 0.2 1.2 13.0 480 367
1 95 6 16.1 0.7 0.2 1.4 19.7 1190 973
1 185 10 22.1 0.7 0.3 1.6 26.5 2290 1963
2 1.5 2.5 3.3 0.7 0.2 1.1 10.0 134 67
2 2.5 2.5 3.8 0.7 0.2 1.1 10.5 170 98
3 1.5 2.5 3.3 0.7 0.2 1.1 10.5 157 80
3 2.5 2.5 3.8 0.7 0.2 1.2 11.0 205 120
3 4 4 4.3 0.7 0.2 1.2 12.5 275 170
3 6 6 4.8 0.7 0.3 1.3 14.5 380 261
3 10 10 5.8 0.7 0.3 1.4 16.8 525 373
3 25 16 9.6 0.9 0.4 1.6 23.0 1150 913
3 35 16 10.8 0.9 0.3 1.7 26.5 1490 1169
3 50 25 12.1 1.0 0.4 1.7 27.0 1930 1563
3 70 35 13.9 1.1 0.6 2.0 30.0 2690 2238
3 95 50 16.1 1.1 0.6 2.2 35.5 3720 3125
5 1.5 4 3.3 0.7 0.2 1.2 12.5 240 1290
7 1.5 6 3.3 0.7 0.2 1.3 13.5 310 1870
12 1.5 6 3.3 0.7 0.3 1.4 18.0 470 2740
19 1.5 6 3.3 0.7 0.3 1.5 21.0 650 3870

297
Shipline BXOI Fire resistant power cable 0.6/1 kV
Halogen free shipcable

Electrical values
Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
1 35 4 SCC 0.524 0.669 0.098 0.118 157 5005
1 95 6 SCC 0.193 0.248 0.089 0.107 293 13585
1 185 10 SCC 0.0991 0.131 0.087 0.104 444 26455
2 1.5 2.5 SCC 12.1 15.4 0.110 0.132 20 210
2 2.5 2.5 SCC 7.41 9.45 0.103 0.124 26 355
3 1.5 2.5 SCC 12.1 15.4 0.110 0.132 16 210
3 2.5 2.5 SCC 7.41 9.45 0.103 0.124 21 355
3 4 4 SCC 4.61 5.88 0.097 0.116 28 570
3 6 6 SCC 3.08 3.93 0.093 0.111 36 855
3 10 10 SCC 1.83 2.33 0.089 0.107 50 1430
3 25 16 SCC 0.727 0.927 0.091 0.109 89 3575
3 35 16 SCC 0.524 0.669 0.087 0.104 110 5005
3 50 25 SCC 0.387 0.494 0.081 0.098 137 7150
3 70 35 SCC 0.268 0.343 0.078 0.094 169 10010
3 95 50 SCC 0.193 0.248 0.076 0.091 205 13585
5 1.5 4 SCC 12.1 15.4 0.120 0.144 13 210
7 1.5 6 SCC 12.1 15.4 0.120 0.144 12 210
12 1.5 6 SCC 12.1 15.4 0.120 0.144 10 210
19 1.5 6 SCC 12.1 15.4 0.120 0.144 8.5 210

SCC = Stranded Circular Conductor

Ordering information
Part Description EAN No. Stock
number KDN Item
128147 BXOI fr 0.6/1kV green 1x35/4 mm2 8711401104359 N
128148 BXOI fr 0.6/1kV green 1x95/6 mm2 8711401104366 N
128149 BXOI fr 0.6/1kV green 1x185/10 mm2 8711401104373 N
125758 BXOI fr 0.6/1kV green 2x1,5/2,5 mm2 8711401030856 Y
125764 BXOI fr 0.6/1kV green 2x2,5/2,5 mm2 8711401030900 N
125760 BXOI fr 0.6/1kV green 3x1,5/2,5 mm2 8711401030863 N
125763 BXOI fr 0.6/1kV green 3x2,5/2,5 mm2 8711401030894 N
126457 BXOI fr 0.6/1kV green 3x4/4 mm2 8711401039422 N
126986 BXOI fr 0.6/1kV green 3x6/6 mm2 8711401050229 N
125765 BXOI fr 0.6/1kV green 3x10/10 mm2 8711401030917 N
128142 BXOI fr 0.6/1kV green 3x25/16 mm2 8711401104304 N
128143 BXOI fr 0.6/1kV green 3x35/16 mm2 8711401104311 N
128144 BXOI fr 0.6/1kV green 3x50/25 mm2 8711401104328 N
128145 BXOI fr 0.6/1kV green 3x70/35 mm2 8711401104335 N
128146 BXOI fr 0.6/1kV green 3x95/50 mm2 8711401104342 N
126456 BXOI fr 0.6/1kV green 5x1,5/4 mm2 8711401039415 N
125761 BXOI fr 0.6/1kV green 7x1,5/6 mm2 8711401030870 N
125762 BXOI fr 0.6/1kV green 12x1,5/6 mm2 8711401030887 N
128220 BXOI fr 0.6/1kV green 19x1,5/6 mm2 8711401105257 N

298
Shipline BXOI Fire resistant power cable 0.6/1 kV
Halogen free shipcable

Ambient temperature correction factors


Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75
Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

299
Shipline BXOI Fire resistant instrument cable 250V
Halogen free shipcable

BXOI 250V
MGT/XLPE/TCWB/SHF1

Max. conductor temp. : 90C


Nominal voltage : 250V

Application Standards applied


Design - IEC 60092-353
Armoured fire resistant cable for fixed installations Conductor - IEC 60228 class 2
on ships where cable protection is required. Insulation - IEC 60092-351
For critical control, alarm and emergency systems. Sheath - IEC 60092-359
Can be installed and operated both indoors and Fire retardant - IEC 60332-3-22 (cat. A)
outdoors. Fire resistant - IEC 60331-21
Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Conductor Annealed stranded circular copper conductors

Insulation B Mica glass tape and crosslinked polyethylene, XLPE

Numbered white cores twisted in pairs (two pair type may be built up
as a star quad). The pairs are twisted with different lay length to
Lay up
reduce mutual capacitance. Over the laid up cores one or more tapes
may be applied

Inner covering X No inner covering

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} BXOI 250 V .. pair/triple/quad .. mm2


Marking text IEC60092-376 IEC60331 IEC60332-3-22 ShipLine {year of
manufacture} {length indication (meter)}
Outer sheath Green
colour

300
Shipline BXOI Fire resistant instrument cable 250V
Halogen free shipcable

Identification of elements

White cores with black numbers

The pairs have the following number identification


according to IEC 60092-376

Pair no. 1 core no. 1 and 2


Pair no. 2 core no. 3 and 4
Pair no. 3 core no. 5 and 6
Pair no. 4 etc.

The single triple is identified


with no 1, 2 and 3

1
The single quad cable has the
4 + 3
following identification
2

Range and dimensions


Elements Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
(pair) cross cross conductor thickness diameter sheath sheath approx. content
(triple) section section diameter (mm) thickness diameter approx.
(quad) (mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
1 pair 0.75 - 2.35 0.7 0.2 1.0 8.5 95 44
1 pair 1.5 - 2.85 0.7 0.2 1.0 9.5 115 73
2 pair 0.75 - 2.35 0.7 0.2 1.2 13.0 170 73
4 pair 0.75 - 2.35 0.7 0.2 1.2 15.5 240 108
7 pair 0.75 - 2.35 0.7 0.3 1.3 18.5 390 198
10 pair 0.75 - 2.35 0.7 0.3 1.5 23.5 550 265

Electrical values
Type Capacitance Inductance Resistance
approx. Approx. at 20 oC
(nF/km) (mH/km) (Ohm/km)
Unshielded pair/quad 0.75 mm2 55 0.75 24.8
Unshielded pair/quad 1.5 mm2 65 0.67 12.2

301
Shipline BXOI Fire resistant instrument cable 250V
Halogen free shipcable

Ordering information
Part Description EAN No. Stock
number KDN Item
125560 BXOI fr 250V gn# 1x2x0,75 mm2 8711401030931 No
127041 BXOI fr 250V gn# 1x2x1,5 mm2 8711401058065 No
125766 BXOI fr 250V gn# 2x2x0,75 mm2 8711401030924 No
127139 BXOI fr 250V gn# 4x2x0,75 mm2 8711401062147 No
125767 BXOI fr 250V gn# 7x2x0,75 mm2 8711401030955 No
125840 BXOI fr 250V gn# 10x2x0,75 mm2 8711401031655 No

Ambient temperature correction factors


Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75
Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

302
TFOI 12kV(2).doc
21.06.2006 14:02
Page 1 of 2

Shipline TFOI 6/10(12)kV MV Power cable


Flame retardant halogen-free medium
voltage (MV) power cable. Braided

TFOI 6/10(12) kV
XLPE/EPR/TCWB/PO

Operating temperature : 90C


Operating Voltage : 6/10(12) kV

Standards applied

Application IEC 60092-354 - Design


IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Armoured cable for fixed installation in ships where cable
protection is required. Medium Voltage power distribution. Can be IEC 60092-359 - Sheath
installed and operated both indoors and outdoors. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Annealed stranded circular copper, IEC 60228 class 2
Conductor screen Extruded semiconductive layer
semiconductive
Insulation T Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)
Extruded semiconductive layer. A copper tape is applied as a metallic
Insulation screen
screen above the insulation screen. The thickness of the copper tape is 0,1
semicoductive
mm.
Cores are laid up together. Cores are identified by White, Black or Red
Lay up / Shielding
threads under and over the metallic screen on each conductor.
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over bedding Additional tape may be applied
Armour/screen O Tinned copper wire braid
Tape over Additional tape may be applied
armour/screen
Outer sheath I Flame retardant halogen-free thermoplastic compound, SHF1
E.g. "meter" "year" DRAKA NORSK KABEL TFOI 6/10(12)KV 3 x 95/50
Marking text
mm2 IEC 60332-3-22 ShipLine
Outer sheath colour Red

www.drakaMOG.com
303
TFOI 12kV(2).doc
21.06.2006 14:02
Page 2 of 2

Shipline TFOI 6/10(12)kV MV Power cable


Range and dimensions
Cross Cross Thickness Diameter Weight Copper
Number Conductor Insulation Thickness Diameter Diameter
section section Outer outer of Cable content
of Diameter, Thickness, Bedding, bedding, Braid
core, screen, Sheath, sheath, Approx. Approx.
elements mm mm mm mm Wire, mm
mm mm mm mm (Kg/Km) (kg/km)
1 95 10 11.2 3.4 1 22.5 1 0.3 1.7 27 1 1640 1094
30.5
1 150 10 14.2 3.4 1 26 1 0.3 1.8 2220 1542
1.5
55.5
3 95 50 11.2 3.4 1.8 48.5 2 0.5 2.6 6060 3390
2.5
52.5
3 120 60 12.6 3.4 1.8 0.6 2.7 60 3 7270 4291
2.5

Ordering information
Part number Description EAN No. DNK EL No. KDN Part number EAN no. KDN
838504 TFOI 6/10(12)KV 1X 95/10mm2 7021528385045 - - -
838506 TFOI 6/10(12)KV 1X 150/10mm2 7021528385069 - - -
838525 TFOI 6/10(12)kV 3X 95/50mm 7021528385250 - - -
838526 TFOI 6/10(12)kV 3X 120/60mm 7021528385267 - - -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Capacitans Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, per phase, rating circuit
elements core, screen, resistance resistance Ohm/km Ohm/km nF/km IEC rating 1
mm mm at 20C, at 90C, 60092- second,
Ohm/km Ohm/km 352, Ampere
Ampere
1 95 10 SCC 0.193 0.246 0.119 0.143 300 293 16800
1 150 10 SCC 0.124 0.158 0.113 0.136 360 389 21000
3 95 50 SCC 0.193 0.246 0.091 0.109 300 205 4900
3 120 60 SCC 0.153 0.195 0.088 0.106 330 237 9800

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
15 x D 9xD 50 N /mm -10C

www.drakaMOG.com
304
Shipline TI Power cable 0.6/1 kV
Halogen free shipcable

TI 0.6/1kV
XLPE/SHF1

Max. conductor temp. : 90C


Nominal voltage : 0.6/1 kV

Application Standards applied


Design - IEC 60092-353
Unarmoured cable for fixed installations on ships Conductor - IEC 60228 class 2
where cable protection is not required. Insulation - IEC 60092-351
For power, control and lighting systems. Sheath - IEC 60092-359
Can be installed and operated both indoors and Fire retardant - IEC 60332-3-22 (cat. A)
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector
Conductor
shaped conductors, other types circular conductors
Insulation T Crosslinked polyethylene, XLPE

Lay up Polyester tape(s) may be applied over the laid up cores

Inner covering No inner covering

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} TI 0,6/1 kV ..x.. mm2 IEC60332-3-22


Marking text
ShipLine {year of manufacture} {length indication (meter)}
Outer sheath Black
colour

305
Shipline TI Power cable 0.6/1 kV
Halogen free shipcable

Core identification

Single core Black


Two cores Blue - Brown
Three cores Brown - Black - Grey
Four cores Blue - Brown - Black - Grey
Five cores Blue - Brown - Black - Grey - Black
Multi core White with black numbers

with yellow/green (optional)


Two cores + earth (3G) Yellow/green - Blue - Brown
Three cores + earth (4G) Yellow/green - Brown - Black - Grey
Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
1 10 - 5.4 0.7 - 1.0 7.5 130 85
1 16 - 6.4 0.7 - 1.0 8.5 190 136
1 25 - 8.1 0.9 - 1.1 10.4 295 217
1 35 - 9.4 0.9 - 1.1 11.7 380 300
1 50 - 10.8 1.0 - 1.2 13.3 510 405
1 70 - 12.8 1.1 - 1.3 15.5 720 587
1 95 - 14.7 1.1 - 1.3 17.4 970 819
1 120 - 16.5 1.2 - 1.4 19.4 1220 1040
1 150 - 18.4 1.4 - 1.5 21.5 1505 1282
1 185 - 20.7 1.6 - 1.5 23.8 1865 1606
1 240 - 23.4 1.7 - 1.6 26.7 2420 2108
1 300 - 26.0 1.8 - 1.7 29.6 3015 2642
2 1.5 - 3.0 0.7 - 1.1 8.4 80 26
2 1.5 - 3.0 0.7 - 1.1 8.4 80 26
2 2.5 - 3.5 0.7 - 1.1 9.2 100 42
2 4 - 4.0 0.7 - 1.1 10.3 135 69
2 6 - 4.5 0.7 - 1.2 11.6 185 102
2 10 - 5.4 0.7 - 1.2 13.3 270 170
2 16 - 6.4 0.7 - 1.3 15.6 400 273
3G 1.5 - 3.0 0.7 - 1.1 8.8 100 39
3G 2.5 - 3.5 0.7 - 1.1 9.8 130 64
3G 4 - 4.0 0.7 - 1.2 11.1 190 104
3G 6 - 4.5 0.7 - 1.2 12.3 250 153
3G 16 - 6.4 0.7 - 1.3 16.6 560 410
3 1.5 - 3.0 0.7 - 1.1 8.8 100 39
3 2.5 - 3.5 0.7 - 1.1 9.8 130 64
3 4 - 4.0 0.7 - 1.2 11.1 190 104
3 6 - 4.5 0.7 - 1.2 12.3 250 153
3 10 - 5.4 0.7 - 1.3 14.3 380 56
3 16 - 6.4 0.7 - 1.3 16.6 560 410
3 25 - 8.1 0.9 - 1.5 20.7 875 655

306
Shipline TI Power cable 0.6/1 kV
Halogen free shipcable

Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
3 35 - 9.4 0.9 - 1.6 23.5 1220 904
3 35 - 7.8/12.4 0.9 - 1.5 20.1 1135 917
3 50 - 8.9/14.2 1.0 - 1.7 22.8 1530 1251
3 70 - 10.5/16.9 1.1 - 1.8 26.7 2150 1802
3 95 - 12.1/19.7 1.1 - 1.9 30.2 2900 2470
3 120 - 13.5/21.9 1.2 - 2.1 34.0 3675 3152
4G 1.5 - 3.0 0.7 - 1.1 9.6 120 52
4G 2.5 - 3.5 0.7 - 1.1 10.7 165 85
4G 4 - 4.0 0.7 - 1.2 12.2 240 138
4G 6 - 4.5 0.7 - 1. 13.5 320 204
4G 10 - 5.4 0.7 - 1.3 15.7 490 342
4G 16 - 6.4 0.7 - 1.4 18.5 740 548
4G 25 - 8.1 0.9 - 1.5 22.8 1145 874
4G 35 - 9.4 0.9 - 1.7 26.0 1515 1207
4 1.5 - 3.0 0.7 - 1.1 9.6 120 52
4 2.5 - 3.5 0.7 - 1.1 10.7 165 85
4 4 - 4.0 0.7 - 1.2 12.2 240 138
4 6 - 4.5 0.7 - 1.2 13.5 320 204
4 10 - 5.4 0.7 - 1.3 15.7 490 342
4 16 - 6.4 0.7 - 1.4 18.5 740 548
4 25 - 8.1 0.9 - 1.5 22.8 1145 874
5G 1.5 - 3.0 0.7 - 1.1 10.5 145 66
5G 2.5 - 3.5 0.7 - 1.2 11.9 205 106
5G 6 - 4.5 0.7 - 1.3 15.0 400 255
5G 16 - 6.4 0.7 - 1.5 20.5 920 686
5 1.5 - 3.0 0.7 - 1.1 10.5 145 66
5 2.5 - 3.5 0.7 - 1.2 11.9 205 106
6 1.5 - 3.0 0.7 - 1.2 11.6 180 80
7 1.5 - 3.0 0.7 - 1.2 11.7 195 93
8G 1.5 - 3.0 0.7 - 1.2 12.7 225 106
8 1.5 - 3.0 0.7 - 1.2 12.7 225 106
10 1.5 - 3.0 0.7 - 1.3 14.8 275 133
12 1.5 - 3.0 0.7 - 1.3 15.3 315 160
16 1.5 - 3.0 0.7 - 1.4 17.2 410 213
19 1.5 - 3.0 0.7 - 1.4 18.1 470 253
24 1.5 - 3.0 0.7 - 1.5 21.3 620 320

307
Shipline TI Power cable 0.6/1 kV
Halogen free shipcable

Electrical values
Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
1 10 - SCC 1.83 2.33 0.105 0.126 72 1430
1 16 - SCC 1.15 1.47 0.098 0.118 96 2285
1 25 - SCC 0.727 0.927 0.096 0.115 127 3575
1 35 - SCC 0.524 0.669 0.091 0.110 157 5005
1 50 - SCC 0.387 0.494 0.087 0.105 196 7150
1 70 - SCC 0.268 0.343 0.085 0.102 242 10010
1 95 - SCC 0.193 0.248 0.082 0.098 293 13585
1 120 - SCC 0.153 0.198 0.081 0.097 339 17160
1 150 - SCC 0.124 0.162 0.081 0.097 389 21450
1 185 - SCC 0.0991 0.131 0.080 0.096 444 26455
1 240 - SCC 0.0754 0.102 0.079 0.094 522 34320
1 300 - SCC 0.0601 0.0831 0.078 0.093 601 42900
2 1.5 - SCC 12.1 15.4 0.104 0.125 20 210
2 1.5 - SCC 12.1 15.4 0.104 0.125 20 210
2 2.5 - SCC 7.41 9.45 0.098 0.118 26 355
2 4 - SCC 4.61 5.88 0.092 0.110 34 570
2 6 - SCC 3.08 3.93 0.088 0.106 44 855
2 10 - SCC 1.83 2.33 0.084 0.101 61 1430
2 16 - SCC 1.15 1.47 0.080 0.096 82 2285
3G 1.5 - SCC 12.1 15.4 0.104 0.125 20 210
3G 2.5 - SCC 7.41 9.45 0.098 0.118 26 355
3G 4 - SCC 4.61 5.88 0.092 0.110 34 570
3G 6 - SCC 3.08 3.93 0.088 0.106 44 855
3G 16 - SCC 1.15 1.47 0.080 0.096 82 2285
3 1.5 - SCC 12.1 15.4 0.104 0.125 16 210
3 2.5 - SCC 7.41 9.45 0.098 0.118 21 355
3 4 - SCC 4.61 5.88 0.092 0.110 28 570
3 6 - SCC 3.08 3.93 0.088 0.106 36 855
3 10 - SCC 1.83 2.33 0.084 0.100 50 1430
3 16 - SCC 1.15 1.47 0.080 0.096 67 2285
3 25 - SCC 0.727 0.927 0.080 0.097 89 3575
3 35 - SCC 0.524 0.669 0.078 0.093 110 5005
3 35 - SSC 0.524 0.669 0.074 0.089 110 5005
3 50 - SSC 0.387 0.494 0.071 0.085 137 7150
3 70 - SSC 0.268 0.343 0.070 0.084 169 10010
3 95 - SSC 0.193 0.248 0.069 0.083 205 13585
3 120 - SSC 0.153 0.198 0.068 0.082 237 17160
4G 1.5 - SCC 12.1 15.4 0.112 0.134 16 210
4G 2.5 - SCC 7.41 9.45 0.105 0.126 21 355
4G 4 - SCC 4.61 5.88 0.099 0.119 28 570
4G 6 - SCC 3.08 3.93 0.095 0.114 36 855
4G 10 - SCC 1.83 2.33 0.091 0.109 50 1430
4G 16 - SCC 1.15 1.47 0.087 0.105 67 2285
4G 25 - SCC 0.727 0.927 0.088 0.105 89 3575
4G 35 - SCC 0.524 0.669 0.088 0.105 110 5005
4 1.5 - SCC 12.1 15.4 0.112 0.134 14 210
4 2.5 - SCC 7.41 9.45 0.105 0.126 18 355
4 4 - SCC 4.61 5.88 0.099 0.119 25 570
4 6 - SCC 3.08 3.93 0.095 0.114 32.5 855

308
Shipline TI Power cable 0.6/1 kV
Halogen free shipcable

Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
4 10 - SCC 1.83 2.33 0.091 0.109 45 1430
4 16 - SCC 1.15 1.47 0.087 0.105 60 2285
4 25 - SCC 0.727 0.927 0.088 0.105 80 3575
5G 1.5 - SCC 12.1 15.4 0.114 0.137 14 210
5G 2.5 - SCC 7.41 9.45 0.108 0.130 18 355
5G 6 - SCC 3.08 3.93 0.098 0.118 32.5 855
5G 16 - SCC 1.15 1.47 0.090 0.108 60 2285
5 1.5 - SCC 12.1 15.4 0.114 0.137 13 210
5 2.5 - SCC 7.41 9.45 0.108 0.130 16.5 355
6 1.5 - SCC 12.1 15.4 0.104 0.125 12.5 210
7 1.5 - SCC 12.1 15.4 0.104 0.125 12 210
8G 1.5 - SCC 12.1 15.4 0.104 0.125 12 210
8 1.5 - SCC 12.1 15.4 0.104 0.125 11.5 210
10 1.5 - SCC 12.1 15.4 0.104 0.125 10.5 210
12 1.5 - SCC 12.1 15.4 0.104 0.125 10 210
16 1.5 - SCC 12.1 15.4 0.104 0.125 9 210
19 1.5 - SCC 12.1 15.4 0.104 0.125 8.5 210
24 1.5 - SCC 12.1 15.4 0.104 0.125 7.5 210

SCC = Stranded Circular Conductor


SSC = Stranded Sector Conductor

Ordering information
Part Description EAN No. Stock
number KDN Item
124831 TI 0,6/1kV black 1x10 mm2 8711401093066 Yes
124832 TI 0,6/1kV black 1x16 mm2 8711401088925 Yes
124833 TI 0,6/1kV black 1x25 mm2 8711401093103 Yes
124834 TI 0,6/1kV black 1x35 mm2 8711401089113 Yes
124835 TI 0,6/1kV black 1x50 mm2 8711401093097 Yes
124836 TI 0,6/1kV black 1x70 mm2 8711401089137 Yes
124837 TI 0,6/1kV black 1x95 mm2 8711401089144 Yes
124838 TI 0,6/1kV black 1x120 mm2 8711401093110 Yes
125521 TI 0,6/1kV black 1x150 mm2 8711401089724 Yes
124839 TI 0,6/1kV black 1x185 mm2 8711401093127 No
124840 TI 0,6/1kV black 1x240 mm2 8711401093134 No
127344 TI 0,6/1kV black 1x300 mm2 8711401093707 No
124841 TI 0,6/1kV black 2x1,5 mm2 8711401093141 Yes
128486 TI 0,6/1kV red 2x1,5 mm2 8711401111784 No
124842 TI 0,6/1kV black 2x2,5 mm2 8711401093165 Yes
124843 TI 0,6/1kV black 2x4 mm2 8711401093172 Yes
124844 TI 0,6/1kV black 2x6 mm2 8711401093189 Yes
124845 TI 0,6/1kV black 2x10 mm2 8711401093196 No
124846 TI 0,6/1kV black 2x16 mm2 8711401093219 Yes
124850 TI 0,6/1kV black 3G1,5 mm2 8711401093233 No
125526 TI 0,6/1kV black 3G2,5 mm2 8711401089175 No
127213 TI 0,6/1kV black 3G4 mm2 8711401093677 No
127215 TI 0,6/1kV black 3G6 mm2 8711401093684 No
127472 TI 0,6/1kV black 3G16 mm2 8711401101433 No
124849 TI 0,6/1kV black 3x1,5 mm2 8711401093226 Yes
124851 TI 0,6/1kV black 3x2,5 mm2 8711401093240 Yes
124852 TI 0,6/1kV black 3x4 mm2 8711401089748 Yes
124853 TI 0,6/1kV black 3x6 mm2 8711401093257 Yes
124854 TI 0,6/1kV black 3x10 mm2 8711401093264 Yes
124855 TI 0,6/1kV black 3x16 mm2 8711401093271 Yes
124856 TI 0,6/1kV black 3x25 mm2 8711401093288 Yes
124857 TI 0,6/1kV black 3x35 mm2 8711401093295 No
125838 TI 0,6/1kV black 3x35 mm2 shaped 8711401093639 No

309
Shipline TI Power cable 0.6/1 kV
Halogen free shipcable

Part Description EAN No. Stock


number KDN Item
124858 TI 0,6/1kV black 3x50 mm2 shaped 8711401093318 Yes
124859 TI 0,6/1kV black 3x70 mm2 shaped 8711401093325 Yes
124860 TI 0,6/1kV black 3x95 mm2 shaped 8711401093332 Yes
124861 TI 0,6/1kV black 3x120 mm2 shaped 8711401093349 No
124864 TI 0,6/1kV black 4G1,5 mm2 8711401089168 No
127212 TI 0,6/1kV black 4G2,5 mm2 8711401093660 No
127214 TI 0,6/1kV black 4G4 mm2 8711401089182 No
127216 TI 0,6/1kV black 4G6 mm2 8711401089199 No
127345 TI 0,6/1kV black 4G10 mm2 8711401093714 No
127416 TI 0,6/1kV black 4G16 mm2 8711401100283 No
127343 TI 0,6/1kV black 4G25 mm2 8711401093691 No
128332 TI 0,6/1kV black 4G35 mm2 8711401106322 No
124863 TI 0,6/1kV black 4x1,5 mm2 8711401093356 Yes
124865 TI 0,6/1kV black 4x2,5 mm2 8711401093370 Yes
124866 TI 0,6/1kV black 4x4 mm2 8711401093387 Yes
124867 TI 0,6/1kV black 4x6 mm2 8711401093394 Yes
124868 TI 0,6/1kV black 4x10 mm2 8711401093424 Yes
124869 TI 0,6/1kV black 4x16 mm2 8711401093431 Yes
127200 TI 0,6/1kV black 4x25 mm2 8711401093653 No
124871 TI 0,6/1kV black 5G1,5 mm2 8711401089731 No
124873 TI 0,6/1kV black 5G2,5 mm2 8711401093509 No
128420 TI 0,6/1kV black 5G6 mm2 8711401107893 No
127997 TI 0,6/1kV black 5G16 mm2 8711401102010 No
124870 TI 0,6/1kV black 5x1,5 mm2 8711401093448 Yes
124872 TI 0,6/1kV black 5x2,5 mm2 8711401093462 Yes
124874 TI 0,6/1kV black 6x1,5 mm2 8711401093516 Yes
124876 TI 0,6/1kV black 7x1,5 mm2 8711401093523 Yes
126447 TI 0,6/1kV black 8G1,5 mm2 8711401093646 No
124877 TI 0,6/1kV black 8x1,5 mm2 8711401093547 Yes
124878 TI 0,6/1kV black 10x1,5 mm2 8711401093561 Yes
124879 TI 0,6/1kV black 12x1,5 mm2 8711401093578 Yes
124880 TI 0,6/1kV black 16x1,5 mm2 8711401093592 Yes
124881 TI 0,6/1kV black 19x1,5 mm2 8711401093615 Yes
124882 TI 0,6/1kV black 24x1,5 mm2 8711401093622 Yes

Ambient temperature correction factors


Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75
Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

310
Shipline TI(c) Control cable 1000V
Halogen free shipcable

TI(c) 0.6/1kV
XLPE/OSCR/SHF1

Max. conductor temp. : 90C


Nominal voltage : 1000V

Application Standards applied


Design - IEC 60092-353
Unarmoured cable for fixed installations on ships Conductor - IEC 60228 class 2
where cable protection is not required. Insulation - IEC 60092-351
For control systems. Sheath - IEC 60092-359
Can be installed and operated both indoors and Fire retardant - IEC 60332-3-22 (cat. A)
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Conductor Annealed stranded circular copper conductors

Insulation T Crosslinked polyethylene, XLPE

Lay up Over the laid up cores one or more tapes may be applied

Inner covering No inner covering

c Copper backed polyester tape with a tinned copper drain wire


Shield
of 1,5 mm2

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} TI 0,6/1 kV ..x.. mm2 IEC60332-3-22


Marking text
ShipLine ** {year of manufacture} {length indication (meter)}
Outer sheath Black
colour

311
Shipline TI(c) Control cable 1000V
Halogen free shipcable

Core identification
White cores with black numbers

Range and dimensions


Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
2 1.5 1.5 3.0 0.7 - 1.1 8.7 95 38
2 2.5 1.5 3.4 0.7 - 1.1 9.6 120 54
3 1.5 1.5 3.0 0.7 - 1.1 9.2 120 51
3 2.5 1.5 3.4 0.7 - 1.1 10.1 155 75
4 1.5 1.5 3.0 0.7 - 1.1 10.0 145 64
5 1.5 1.5 3.0 0.7 - 1.1 10.8 170 77
7 1.5 1.5 3.0 0.7 - 1.2 12.0 215 104
12 1.5 1.5 3.0 0.7 - 1.3 15.6 340 170
19 1.5 1.5 3.0 0.7 - 1.4 18.4 495 262
32 1.5 1.5 3.0 0.7 1.6 23.8 805 434

Electrical values
Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
2 1.5 1.5 SCC 12.1 15.4 0.103 0.124 20 210
2 2.5 1.5 SCC 7.41 9.45 0.112 0.135 26 355
3 1.5 1.5 SCC 12.1 15.4 0.103 0.124 16 210
3 2.5 1.5 SCC 7.41 9.45 0.112 0.135 21 355
4 1.5 1.5 SCC 12.1 15.4 0.111 0.133 14 210
5 1.5 1.5 SCC 12.1 15.4 0.113 0.136 13 210
7 1.5 1.5 SCC 12.1 15.4 0.103 0.124 12 210
12 1.5 1.5 SCC 12.1 15.4 0.103 0.124 10 210
19 1.5 1.5 SCC 12.1 15.4 0.103 0.124 8.5 210
32 1.5 1.5 SCC 12.1 15.4 0.103 0.124 7.5 210

SCC = Stranded Circular Conductor

312
Shipline TI(c) Control cable 1000V
Halogen free shipcable

Ordering information
Part Description EAN No. Stock
number KDN Item
127228 TI(c) 0,6/1kV black 2x1,5 mm2 8711401072900 No
127293 TI(c) 0,6/1kV black 2x2,5 mm2 8711401088222 No
127341 TI(c) 0,6/1kV black 3x1,5 mm2 8711401088499 No
127391 TI(c) 0,6/1kV black 3x2,5 mm2 8711401099433 No
127387 TI(c) 0,6/1kV black 4x1,5 mm2 8711401099037 No
127388 TI(c) 0,6/1kV black 5x1,5 mm2 8711401099051 No
127291 TI(c) 0,6/1kV black 7x1,5 mm2 8711401085528 No
127292 TI(c) 0,6/1kV black 12x1,5 mm2 8711401087768 No
127389 TI(c) 0,6/1kV black 19x1,5 mm2 8711401099730 No
127390 TI(c) 0,6/1kV black 32x1,5 mm2 8711401099761 No

Ambient temperature correction factors


Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75
Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

313
Shipline TXOI Power cable 0.6/1 kV
Braided halogen free shipcable

TXOI 0.6/1kV
XLPE/TCWB/SHF1

Max. conductor temp. : 90C


Nominal voltage : 0.6/1 kV

Application Standards applied


Design - IEC 60092-353
Armoured cable for fixed installations on ships Conductor - IEC 60228 class 2
where cable protection is required. Insulation - IEC 60092-351
For power, control and lighting systems. Sheath - IEC 60092-359
Can be installed and operated both indoors and Flame retardant - IEC 60332-3-22 (cat. A)
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded copper, 3- and 4-core cables >= 35 mm2 sector
Conductor
shaped conductors, other types circular conductors

Insulation T Crosslinked polyethylene, XLPE

Lay up Polyester tape(s) may be applied over the laid up cores

Inner covering X No inner covering

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} TXOI 0,6/1 kV ..x../.. mm2 IEC60332-3-22


Marking text
ShipLine {year of manufacture} {length indication (meter)}
Outer sheath Black
colour

314
Shipline TXOI Power cable 0.6/1 kV
Braided halogen free shipcable

Core identification

Single core Black


Two cores Blue - Brown
Three cores Brown - Black - Grey
Four cores Blue - Brown - Black - Grey
Five cores Blue - Brown - Black - Grey - Black
Multi core White with black numbers

with yellow/green (optional)


Two cores + earth (3G) Yellow/green - Blue - Brown
Three cores + earth (4G) Yellow/green - Brown - Black - Grey
Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
1 16 2.5 6.4 0.7 0.2 1.1 9.8 245 174
1 25 4 8.1 0.9 0.2 1.2 11.7 355 264
1 35 4 9.4 0.9 0.2 1.2 13.0 455 353
1 50 6 10.8 1.0 0.3 1.3 15.0 620 494
1 70 6 12.8 1.1 0.3 1.4 17.2 850 691
1 95 10 14.7 1.1 0.3 1.4 19.1 1115 936
1 120 10 16.5 1.2 0.3 1.5 21.1 1385 1174
1 150 10 18.4 1.4 0.3 1.6 23.2 1690 1435
1 185 10 20.7 1.6 0.3 1.6 25.5 2065 1769
1 240 10 23.4 1.7 0.3 1.7 28.4 2640 2292
1 300 16 26.0 1.8 0.3 1.8 31.3 3260 2845
2 1.5 2.5 3.0 0.7 0.2 1.1 9.3 120 62
2 2.5 2.5 3.5 0.7 0.2 1.1 10.1 150 83
2 4 4 4.0 0.7 0.2 1.2 11.4 195 115
2 6 6 4.5 0.7 0.3 1.2 12.9 275 180
2 10 10 5.4 0.7 0.3 1.3 14.9 385 267
2 16 16 6.4 0.7 0.3 1.4 17.6 595 445
2 25 16 8.1 0.9 0.4 1.5 21.3 820 614
3G 1.5 2.5 3.0 0.7 0.2 1.1 9.8 145 78
3G 2.5 2.5 3.5 0.7 0.2 1.1 10.7 180 105
3 1.5 2.5 3.0 0.7 0.2 1.1 9.8 145 78
3 2.5 2.5 3.5 0.7 0.2 1.1 10.7 180 105
3 4 4 4.0 0.7 0.2 1.2 12.0 245 151
3 6 6 4.5 0.7 0.3 1.3 13.8 345 233
3 10 10 5.4 0.7 0.3 1.3 15.7 490 352
3 16 16 6.4 0.7 0.4 1.4 18.6 755 582
3 25 16 8.1 0.9 0.4 1.6 22.7 1095 842
3 35 16 9.4 0.9 0.3 1.6 24.9 1340 1073
3 50 25 8.9/14.3 1.0 0.4 1.6 24.8 1820 1508
3 70 35 10.5/16.9 1.1 0.6 2.0 29.7 2575 2161
3 95 50 12.1/19.7 1.1 0.6 2.1 33.1 3435 2943

315
Shipline TXOI Power cable 0.6/1 kV
Braided halogen free shipcable

Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
3 120 25 13.5/21.9 1.2 0.4 2.2 36.0 4070 3500
3 120 60 13.5/21.9 1.2 0.4 2.3 37.8 4470 3863
3 150 25 15.2/24.7 1.4 0.4 2.3 39.1 4945 4269
3 150 70 15.2/24.7 1.4 0.4 2.4 40.9 5435 4722
4G 1.5 2.5 3.0 0.7 0.2 1.1 10.5 170 93
4G 2.5 2.5 3.5 0.7 0.2 1.2 11.8 225 131
4 1.5 2.5 3.0 0.7 0.2 1.1 10.5 170 93
4 2.5 2.5 3.5 0.7 0.2 1.2 11.8 225 131
4 4 4 4.0 0.7 0.3 1.3 13.7 335 217
4 6 6 4.5 0.7 0.3 1.3 15.0 425 293
4 10 10 5.4 0.7 0.3 1.4 17.3 625 455
4 16 16 6.4 0.7 0.4 1.5 20.5 935 719
4 25 16 8.1 0.9 0.3 1.6 24.4 1345 1043
4 35 16 9.4 0.9 0.3 1.7 27.5 1715 1384
4 70 35 11.5/15.5 1.1 0.4 2.1 32.8 3250 2746
4 95 50 13.3/18.0 1.1 0.6 2.2 37.3 4390 3783
5 1.5 2.5 3.0 0.7 0.2 1.2 11.7 205 111
5 2.5 4 3.5 0.7 0.2 1.2 12.8 265 158
6 1.5 4 3.0 0.7 0.2 1.2 12.7 240 132
7 1.5 4 3.0 0.7 0.2 1.2 12.7 260 145
8 1.5 6 3.0 0.7 0.2 1.2 15.5 340 209
10 1.5 6 3.0 0.7 0.3 1.3 16.2 390 231
12 1.5 6 3.0 0.7 0.3 1.4 16.9 440 261
16 1.5 6 3.0 0.7 0.3 1.4 18.6 550 334
19 1.5 6 3.0 0.7 0.3 1.5 19.7 620 376
24 1.5 10 3.0 0.7 0.3 1.6 22.9 800 468

Electrical values
Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
1 16 2.5 SCC 1.15 1.47 0.107 0.128 96 2285
1 25 4 SCC 0.727 0.927 0.103 0.124 127 3575
1 35 4 SCC 0.524 0.669 0.098 0.118 157 5005
1 50 6 SCC 0.387 0.494 0.095 0.114 196 7150
1 70 6 SCC 0.268 0.343 0.092 0110 242 10010
1 95 10 SCC 0.193 0.248 0.088 0.106 293 13585
1 120 10 SCC 0.153 0.198 0.086 0.103 339 17160
1 150 10 SCC 0.124 0.162 0.085 0.103 389 21450
1 185 10 SCC 0.0991 0.131 0.085 0.101 444 26455
1 240 10 SCC 0.0754 0.102 0.082 0.099 522 34320
1 300 16 SCC 0.0601 0.0831 0.081 0.098 601 42900
2 1.5 2.5 SCC 12.1 15.4 0.104 0.125 20 210
2 2.5 2.5 SCC 7.41 9.45 0.098 0.118 26 355
2 4 4 SCC 4.61 5.88 0.092 0.110 34 570
2 6 6 SCC 3.08 3.93 0.088 0.106 44 855
2 10 10 SCC 1.83 2.33 0.084 0.100 61 1430
2 16 16 SCC 1.15 1.47 0.080 0.096 82 2285

316
Shipline TXOI Power cable 0.6/1 kV
Braided halogen free shipcable

Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
2 25 16 SCC 0.727 0.927 0.080 0.097 108 3575
3G 1.5 2.5 SCC 12.1 15.4 0.104 0.125 20 210
3G 2.5 2.5 SCC 7.41 9.45 0.098 0.118 26 355
3 1.5 2.5 SCC 12.1 15.4 0.104 0.125 16 210
3 2.5 2.5 SCC 7.41 9.45 0.098 0.118 21 355
3 4 4 SCC 4.61 5.88 0.092 0.110 28 570
3 6 6 SCC 3.08 3.93 0.088 0.106 36 855
3 10 10 SCC 1.83 2.33 0.084 0.100 50 1430
3 16 16 SCC 1.15 1.47 0.080 0.096 67 2285
3 25 16 SCC 0.727 0.927 0.080 0.097 89 3575
3 35 16 SCC 0.524 0.669 0.078 0.093 110 5005
3 50 25 SSC 0.387 0.494 0.071 0.085 137 7150
3 70 35 SSC 0.268 0.343 0.070 0.084 169 10010
3 95 50 SSC 0.193 0.248 0.069 0.083 205 13585
3 120 25 SSC 0.153 0.198 0.068 0.082 237 17160
3 120 60 SSC 0.153 0.198 0.068 0.082 237 17160
3 150 25 SSC 0.124 0.162 0.068 0.082 272 21450
3 150 70 SSC 0.124 0.162 0.068 0.082 272 21450
4G 1.5 2.5 SCC 12.1 15.4 0.112 0.134 16 210
4G 2.5 2.5 SCC 7.41 9.45 0.105 0.126 21 355
4 1.5 2.5 SCC 12.1 15.4 0.112 0.134 14 210
4 2.5 2.5 SCC 7.41 9.45 0.105 0.126 18 355
4 4 4 SCC 4.61 5.88 0.099 0.119 25 570
4 6 6 SCC 3.08 3.93 0.095 0.114 32.5 855
4 10 10 SCC 1.83 2.33 0.091 0.109 45 1430
4 16 16 SCC 1.15 1.47 0.087 0.105 60 2285
4 25 16 SCC 0.727 0.927 0.088 0.105 80 3575
4 35 16 SCC 0.524 0.669 0.085 0.102 98.5 5005
4 70 35 SSC 0.268 0.343 0.079 0.094 152 10010
4 95 50 SSC 0.193 0.248 0.077 0.093 184.5 13585
5 1.5 2.5 SCC 12.1 15.4 0.114 0.137 13 210
5 2.5 4 SCC 7.41 9.45 0.122 0.147 16.5 355
6 1.5 4 SCC 12.1 15.4 0.104 0.125 12.5 210
7 1.5 4 SCC 12.1 15.4 0.104 0.125 12 210
8 1.5 6 SCC 12.1 15.4 0.104 0.125 11.5 210
10 1.5 6 SCC 12.1 15.4 0.104 0.125 10.5 210
12 1.5 6 SCC 12.1 15.4 0.104 0.125 10 210
16 1.5 6 SCC 12.1 15.4 0.104 0.125 9 210
19 1.5 6 SCC 12.1 15.4 0.104 0.125 8.5 210
24 1.5 10 SCC 12.1 15.4 0.104 0.125 7.5 210

SCC = Stranded Circular Conductor


SSC = Stranded Sector Conductor

317
Shipline TXOI Power cable 0.6/1 kV
Braided halogen free shipcable

Ordering information
Part Description EAN No. Stock
number KDN Item
124884 TXOI 0,6/1kV black 1x16/2,5 mm2 8711401093745 No
124885 TXOI 0,6/1kV black 1x25/4 mm2 8711401093752 No
124886 TXOI 0,6/1kV black 1x35/4 mm2 8711401089212 No
124887 TXOI 0,6/1kV black 1x50/6 mm2 8711401093783 No
124888 TXOI 0,6/1kV black 1x70/6 mm2 8711401089236 No
124889 TXOI 0,6/1kV black 1x95/10 mm2 8711401093790 No
124890 TXOI 0,6/1kV black 1x120/10 mm2 8711401093813 No
124891 TXOI 0,6/1kV black 1x150/10 mm2 8711401088659 No
124892 TXOI 0,6/1kV black 1x185/10 mm2 8711401093820 No
124893 TXOI 0,6/1kV black 1x240/10 mm2 8711401093837 No
128768 TXOI 0,6/1kV black 1x300/16 mm2 8711401122445 No
124894 TXOI 0,6/1kV black 2x1,5/2,5 mm2 8711401093844 Yes
124895 TXOI 0,6/1kV black 2x2,5/2,5 mm2 8711401093851 Yes
124896 TXOI 0,6/1kV black 2x4/4 mm2 8711401093875 Yes
124897 TXOI 0,6/1kV black 2x6/6 mm2 8711401093882 No
124898 TXOI 0,6/1kV black 2x10/10 mm2 8711401093899 No
124899 TXOI 0,6/1kV black 2x16/16 mm2 8711401093950 No
128004 TXOI 0,6/1kV black 2x25/16 mm2 8711401102133 No
127202 TXOI 0,6/1kV black 3G1,5/2,5 mm2 8711401094421 No
127198 TXOI 0,6/1kV black 3G2,5/2,5 mm2 8711401088666 No
124900 TXOI 0,6/1kV black 3x1,5/2,5 mm2 8711401089311 Yes
124901 TXOI 0,6/1kV black 3x2,5/2,5 mm2 8711401093967 Yes
124902 TXOI 0,6/1kV black 3x4/4 mm2 8711401089410 No
124903 TXOI 0,6/1kV black 3x6/6 mm2 8711401093974 Yes
124904 TXOI 0,6/1kV black 3x10/10 mm2 8711401093981 No
124905 TXOI 0,6/1kV black 3x16/16 mm2 8711401088673 Yes
124906 TXOI 0,6/1kV black 3x25/16 mm2 8711401089717 Yes
124907 TXOI 0,6/1kV black 3x35/16 mm2 8711401094018 Yes
124908 TXOI 0,6/1kV black 3x50/25 mm2 shaped 8711401088680 Yes
124909 TXOI 0,6/1kV black 3x70/35 mm2 shaped 8711401094230 Yes
124910 TXOI 0,6/1kV black 3x95/50 mm2 shaped 8711401088697 No
127205 TXOI 0,6/1kV black 3x120/25 mm2 shaped 8711401094452 No
128399 TXOI 0,6/1kV black 3x120/60 mm2 shaped 8711401107626 No
127347 TXOI 0,6/1kV black 3x150/25 mm2 shaped 8711401093035 No
128400 TXOI 0,6/1kV black 3x150/70 mm2 shaped 8711401107633 No
127203 TXOI 0,6/1kV black 4G1,5/2,5 mm2 8711401094445 No
127199 TXOI 0,6/1kV black 4G2,5/2,5 mm2 8711401094414 No
124913 TXOI 0,6/1kV black 4x1,5/2,5 mm2 8711401089373 Yes
124914 TXOI 0,6/1kV black 4x2,5/2,5 mm2 8711401094247 Yes
124915 TXOI 0,6/1kV black 4x4/6 mm2 8711401094254 Yes
124916 TXOI 0,6/1kV black 4x6/6 mm2 8711401094261 Yes
124917 TXOI 0,6/1kV black 4x10/10 mm2 8711401094278 Yes
124918 TXOI 0,6/1kV black 4x16/16 mm2 8711401094285 Yes
124919 TXOI 0,6/1kV black 4x25/16 mm2 8711401094292 No
127411 TXOI 0,6/1kV black 4x35/16 mm2 8711401100160 No
128334 TXOI 0,6/1kV black 4x70/35 mm2 shaped 8711401106339 No
127346 TXOI 0,6/1kV black 4x95/50 mm2 shaped 8711401089830 No
124920 TXOI 0,6/1kV black 5x1,5/2,5 mm2 8711401094308 Yes
124921 TXOI 0,6/1kV black 5x2,5/4 mm2 8711401094339 No
126759 TXOI 0,6/1kV black 6x1,5/4 mm2 8711401045935 No
124924 TXOI 0,6/1kV black 7x1,5/4 mm2 8711401089380 Yes
126760 TXOI 0,6/1kV black 8x1,5/6 mm2 8711401045942 No
124926 TXOI 0,6/1kV black 10x1,5/6 mm2 8711401094346 Yes
124927 TXOI 0,6/1kV black 12x1,5/6 mm2 8711401094353 Yes
124928 TXOI 0,6/1kV black 16x1,5/6 mm2 8711401094377 No
124929 TXOI 0,6/1kV black 19x1,5/6 mm2 8711401094391 Yes
124930 TXOI 0,6/1kV black 24x1,5/10 mm2 8711401094407 No

318
Shipline TXOI Power cable 0.6/1 kV
Braided halogen free shipcable

Ambient temperature correction factors


Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75
Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

319
Shipline TXOI Instrumentation cable 250V
Braided halogen free shipcable

TXOI 250V
XLPE/TCWB/SHF1

Max. conductor temp. : 90C


Nominal voltage : 250V

Application Standards applied


Design - IEC 60092-376
Armoured cable for fixed installations on ships Conductor - IEC 60228 class 2
where cable protection is required. Insulation - IEC 60092-351
For instrumentation and communication systems. Sheath - IEC 60092-359
Can be installed and operated both indoors and Flame retardant - IEC 60332-3-22 (cat A)
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Conductor Annealed stranded circular copper conductors

Insulation T Crosslinked polyethylene, XLPE

Numbered white cores twisted in pairs (two pair type may be built up
as a star quad). The pairs are twisted with different lay length to
Lay up
reduce mutual capacitance. Over the laid up cores one or more tapes
may be applied
Inner covering X No inner covering

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} TXOI 250 V .. pair/triple/quad .. mm2


Marking text IEC60092-376 IEC60332-3-22 ShipLine {year of manufacture}
{length indication (meter)}
Outer sheath Grey
colour

320
Shipline TXOI Instrumentation cable 250V
Braided halogen free shipcable

Identification of elements

White cores with black numbers

The pairs have the following number identification according to IEC 60092-376

Pair no. 1 core no. 1 and 2


Pair no. 2 core no. 3 and 4
Pair no. 3 core no. 5 and 6
Pair no. 4 etc.

The single triple is identified


with no 1, 2 and 3

1
The single quad cable has the
4 + 3
following identification
2

Range and dimensions


Elements Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
(pair) cross cross conductor thickness diameter sheath sheath approx. content
(triple) section section diameter (mm) thickness diameter approx.
(quad) (mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
1 pair 0.5 - 1.8 0.4 0.2 1.0 6.6 65 33
1 quad 0.5 - 1.8 0.4 0.2 1.0 7.3 85 42
1 pair 0.75 - 2.1 0.5 0.2 1.0 9.1 80 41
1 triple 0.75 - 2.1 0.5 0.2 1.0 7.6 90 47
1 quad 0.75 - 2.1 0.5 0.2 1.0 8.2 105 53
4 pair 0.75 - 2.1 0.5 0.2 1.2 12.2 195 100
7 pair 0.75 - 2.1 0.5 0.2 1.2 14.4 270 145
10 pair 0.75 - 2.1 0.5 0.3 1.4 17.8 410 239
14 pair 0.75 - 2.1 0.5 0.3 1.4 19.3 500 291
19 pair 0.75 - 2.1 0.5 0.3 1.5 21.5 630 373
24 pair 0.75 - 2.1 0.5 0.3 1.7 25.2 805 473

Electrical values
Type Capacitance Inductance Resistance
approx. Approx. at 20 oC
(nF/km) (mH/km) (Ohm/km)
Unshielded pair 0.5 mm2 70 0.60 40.4
Unshielded pair 0.75 mm2 65 0.60 26.0

321
Shipline TXOI Instrumentation cable 250V
Braided halogen free shipcable

Ordering information
Part Description EAN No. Stock
number KDN Item
127257 TXOI 250V gy# 1x2x0,5 mm2 s 8711401094636 No
127258 TXOI 250V gy# 1x4x0,5 mm2 s quad 8711401094643 No
124931 TXOI 250V gy# 1x2x0,75 mm2 s 8711401094476 Yes
127243 TXOI 250V gy# 1x3x0,75 mm2 s 8711401072979 No
124933 TXOI 250V gy# 1x4x0,75 mm2 s 8711401094520 Yes
124934 TXOI 250V gy# 4x2x0,75 mm2 s 8711401094537 Yes
124936 TXOI 250V gy# 7x2x0,75 mm2 s 8711401094544 Yes
124937 TXOI 250V gy# 10x2x0,75 mm2 s 8711401094551 Yes
124938 TXOI 250V gy# 14x2x0,75 mm2 s 8711401094568 Yes
124939 TXOI 250V gy# 19x2x0,75 mm2 s 8711401094582 No
124940 TXOI 250V gy# 24x2x0,75 mm2 s 8711401094629 No

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

322
Shipline Plus TFXI Power cable 0.6/1 kV
Halogen free shipcable

TFXI 0.6/1kV
XLPE/SHF1

Max. conductor temp. : 90C


Nominal voltage : 0.6/1 kV

Application Standards applied


Design - IEC 60092-353
Unarmoured cable for fixed installations on ships Conductor - IEC 60228 class 2 and 5
where cable protection is not required. Insulation - IEC 60092-351
For power, control and lighting systems. Sheath - IEC 60092-359
Can be installed and operated both indoors and Fire retardant - IEC 60332-3-22 (cat. A)
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded circular copper conductors, stranded acc IEC
Conductor
60228 class 2 or flexible acc IEC 60228 class 5
Insulation T Crosslinked polyethylene, XLPE

Cores laid up in one or more layers; in case of cables with more


Lay up than 5 cores one or more tapes may be applied over the laid up
cores

F Single core cables no inner covering; 2 5 core cables bedding of


Inner sheath flame retardant halogen free thermoplastic compound SHF1; cables
with more than 5 cores no inner covering
Armour/screen X No armour or screen

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} TFXI 0,6/1 kV ..x.. mm2 IEC60332-3-22


Marking text
ShipLine Plus {year of manufacture} {length indication (meter)}
Outer sheath Black
colour

323
Shipline Plus TFXI Power cable 0.6/1 kV
Halogen free shipcable

Core identification

Single core Black


Two cores Blue - Brown
Three cores Brown - Black - Grey
Four cores Blue - Brown - Black - Grey
Five cores Blue - Brown - Black - Grey - Black
Multi core White with black numbers

with yellow/green (optional)


Two cores + earth (3G) Yellow/green - Blue - Brown
Three cores + earth (4G) Yellow/green - Brown - Black - Grey
Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
Class 5
1 25 - 8.4 0.9 - 1.1 10.7 285 210
1 35 - 9.95 0.9 - 1.1 12.3 390 303
1 50 - 11.75 1.0 - 1.2 14.3 545 434
1 70 - 13.8 1.1 - 1.3 16.5 750 613
1 120 - 17.4 1.2 - 1.4 20.3 1210 1022
3 25 - 8.4 0.9 - 1.5 21.6 1035 635
3 35 - 9.95 0.9 - 1.6 25.2 1440 916
3 50 - 11.75 1.0 - 1.7 30.5 2100 1308
3 70 - 13.8 1.1 - 1.9 35.3 2885 1850
3 95 - 15.3 1.1 - 2.0 39.1 3715 2452

Class 2
1 10 - 5.4 0.7 - 1.0 7.5 130 85
1 16 - 6.4 0.7 - 1.0 8.5 190 136
1 25 - 8.1 0.9 - 1.1 10.4 295 217
1 35 - 9.4 0.9 - 1.1 11.7 380 300
1 50 - 10.8 1.0 - 1.2 13.3 510 405
1 70 - 12.8 1.1 - 1.3 15.5 720 587
1 95 - 14.7 1.1 - 1.3 17.4 970 819
1 120 - 16.5 1.2 - 1.4 19.4 1220 1040
1 150 - 18.4 1.4 - 1.5 21.5 1505 1282
1 185 - 20.7 1.6 - 1.5 23.8 1865 1606
1 240 - 23.4 1.7 - 1.6 26.7 2420 2108
1 400 - 29.3 2.0 - 1.9 33.3 3850 3384
2 1.5 - 3.0 0.7 - 1.0 8.6 110 26
2 2.5 - 3.5 0.7 - 1.1 9.6 150 42
2 4 - 4.0 0.7 - 1.1 10.7 195 69
2 6 - 4.5 0.7 - 1.2 12.0 260 102
2 10 - 5.4 0.7 - 1.2 13.7 370 170
2 16 - 6.4 0.7 - 1.3 16.0 540 273

324
Shipline Plus TFXI Power cable 0.6/1 kV
Halogen free shipcable

Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
3G 1.5 - 3.0 0.7 - 1.1 9.2 130 39
3G 2.5 - 3.5 0.7 - 1.1 10.2 175 64
3 1.5 - 3.0 0.7 - 1.1 9.2 130 39
3 2.5 - 3.5 0.7 - 1.1 10.2 175 64
3 4 - 4.0 0.7 - 1.1 11.3 235 104
3 6 - 4.5 0.7 - 1.2 12.7 315 153
3 10 - 5.4 0.7 - 1.3 14.7 465 256
3 16 - 6.4 0.7 - 1.3 17.0 680 410
3 25 - 8.1 0.9 - 1.5 21.1 1060 655
3 35 - 9.4 0.9 - 1.6 23.9 1390 904
3 50 - 10.8 1.0 - 1.7 28.3 1925 1223
3 70 - 12.8 1.1 - 1.9 33.1 2705 1772
3 95 - 14.7 1.1 - 2.0 37.8 3665 2469
3 120 - 16.5 1.2 - 2.2 42.0 4595 3137
3 150 - 18.4 1.4 - 2.3 46.3 5620 3865
4G 1.5 - 3.0 0.7 - 1.1 10.0 155 52
4G 2.5 - 3.5 0.7 - 1.1 11.1 205 85
4G 6 - 4.5 0.7 - 1.2 13.9 385 204
4 1.5 - 3.0 0.7 - 1.1 10.0 155 52
4 2.5 - 3.5 0.7 - 1.1 11.1 205 85
4 4 - 4.0 0.7 - 1.2 12.6 290 138
4 6 - 4.5 0.7 - 1.2 13.9 385 204
4 10 - 5.4 0.7 - 1.3 16.1 575 342
4 16 - 6.4 0.7 - 1.4 18.9 855 548
5G 1.5 - 3.0 0.7 - 1.1 10.9 185 66
5G 2.5 - 3.5 0.7 - 1.2 12.3 250 106
5 1.5 - 3.0 0.7 - 1.1 10.9 185 66
5 2.5 - 3.5 0.7 - 1.2 12.3 250 106
6 1.5 - 3.0 0.7 - 1.2 11.6 180 80
7 1.5 - 3.0 0.7 - 1.2 11.7 195 93
8G 1.5 - 3.0 0.7 - 1.2 12.7 225 106
8 1.5 - 3.0 0.7 - 1.2 12.7 225 106
10 1.5 - 3.0 0.7 - 1.3 14.8 275 133
12 1.5 - 3.0 0.7 - 1.3 15.3 315 160
16 1.5 - 3.0 0.7 - 1.4 17.2 410 213
19 1.5 - 3.0 0.7 - 1.4 18.1 470 253
24 1.5 - 3.0 0.7 - 1.5 21.3 620 320

325
Shipline Plus TFXI Power cable 0.6/1 kV
Halogen free shipcable

Electrical values
Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
Class 5
1 25 - SCC 0.78 0.995 0.094 0.113 127 3575
1 35 - SCC 0.554 0.706 0.090 0.107 157 5005
1 50 - SCC 0.386 0.492 0.085 0.102 196 7150
1 70 - SCC 0.272 0.347 0.083 0.100 242 10010
1 120 - SCC 0.161 0.205 0.079 0.095 339 17160
3 25 - SCC 0.78 0.995 0.079 0.095 89 3575
3 35 - SCC 0.554 0.706 0.076 0.092 110 5005
3 50 - SCC 0.386 0.492 0.073 0.087 137 7150
3 70 - SCC 0.272 0.347 0.072 0.086 169 10010
3 95 - SCC 0.206 0.263 0.071 0.085 205 13585

Class 2
1 10 - SCC 1.83 2.33 0.105 0.126 72 1430
1 16 - SCC 1.15 1.47 0.098 0.118 96 2285
1 25 - SCC 0.727 0.927 0.096 0.115 127 3575
1 35 - SCC 0.524 0.669 0.091 0.110 157 5005
1 50 - SCC 0.387 0.494 0.087 0.105 196 7150
1 70 - SCC 0.268 0.343 0.085 0.102 242 10010
1 95 - SCC 0.193 0.248 0.082 0.098 293 13585
1 120 - SCC 0.153 0.198 0.081 0.097 339 17160
1 150 - SCC 0.124 0.162 0.080 0.097 389 21450
1 185 - SCC 0.0991 0.131 0.080 0.096 444 26455
1 240 - SCC 0.0754 0.102 00.78 0.094 522 34320
1 400 - SCC 0.047 0.0685 0.078 0.093 670 57200
2 1.5 - SCC 12.1 15.4 0.104 0.125 20 210
2 2.5 - SCC 7.41 9.45 0.098 0.118 26 355
2 4 - SCC 4.61 5.88 0.092 0.110 34 570
2 6 - SCC 3.08 3.93 0.088 0.106 44 855
2 10 - SCC 1.83 2.33 0.084 0.100 61 1430
2 16 - SCC 1.15 1.47 0.080 0.096 82 2285
3G 1.5 - SCC 12.1 15.4 0.104 0.125 20 210
3G 2.5 - SCC 7.41 9.45 0.098 0.118 26 355
3 1.5 - SCC 12.1 15.4 0.104 0.125 16 210
3 2.5 - SCC 7.41 9.45 0.098 0.118 21 355
3 4 - SCC 4.61 5.88 0.092 0.110 28 570
3 6 - SCC 3.08 3.93 0.088 0.106 36 855
3 10 - SCC 1.83 2.33 0.084 0.100 50 1430
3 16 - SCC 1.15 1.47 0.080 0.096 67 2285
3 25 - SCC 0.727 0.927 0.080 0.097 89 3575
3 35 - SCC 0.524 0.669 0.078 0.093 110 5005
3 50 - SCC 0.387 0.494 0.074 0.089 137 7150
3 70 - SCC 0.268 0.343 0.073 0.088 169 10010
3 95 - SCC 0.193 0.248 0.072 0.086 205 13585
3 120 - SCC 0.153 0.198 0.070 0.084 237 17160
3 150 - SCC 0.124 0.162 0.071 0.085 272 21450
4G 1.5 - SCC 12.1 15.4 0112 0.134 16 210
4G 2.5 - SCC 7.41 9.45 0.105 0.126 21 355
4G 6 - SCC 3.08 3.93 0.095 0.114 36 855

326
Shipline Plus TFXI Power cable 0.6/1 kV
Halogen free shipcable

Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
4 1.5 - SCC 12.1 15.4 0.112 0.114 14 855
4 2.5 - SCC 7.41 9.45 0.105 0.134 18 210
4 4 - SCC 4.61 5.88 0.099 0.126 25 355
4 6 - SCC 3.08 3.93 0.095 0.119 32.5 570
4 10 - SCC 1.83 2.33 0.091 0.114 45 855
4 16 - SCC 1.15 1.47 0.087 0.109 60 1430
5G 1.5 - SCC 12.1 15.4 0.114 0.105 14 2285
5G 2.5 - SCC 7.41 9.45 0.108 0.137 18 210
5 1.5 - SCC 12.1 15.4 0.114 0.130 13 355
5 2.5 - SCC 7.41 9.45 0.108 0.137 16.5 210
6 1.5 - SCC 12.1 15.4 0.104 0.130 12.5 355
7 1.5 - SCC 12.1 15.4 0.104 0.125 12 210
8G 1.5 - SCC 12.1 15.4 0.104 0.125 12 210
8 1.5 - SCC 12.1 15.4 0.104 0.125 11.5 210
10 1.5 - SCC 12.1 15.4 0.104 0.125 10.5 210
12 1.5 - SCC 12.1 15.4 0.104 0.125 10 210
16 1.5 - SCC 12.1 15.4 0.104 0.125 9 210
19 1.5 - SCC 12.1 15.4 0.104 0.125 8.5 210
24 1.5 - SCC 12.1 15.4 0.104 0.125 7.5 210

SCC = Stranded Circular Conductor

Ordering information
Part Description EAN No. Stock
number KDN Item
128234 TFXI cl5 0,6/1kV black 1x25 mm2 8711401105431 N
128235 TFXI cl5 0,6/1kV black 1x35 mm2 8711401105462 N
128236 TFXI cl5 0,6/1kV black 1x50 mm2 8711401105493 N
128237 TFXI cl5 0,6/1kV black 1x70 mm2 8711401105523 N
128636 TFXI cl5 0,6/1kV black 1x120 mm2 8711401116505 N
128243 TFXI cl5 0,6/1kV black 3x25 mm2 8711401105547 N
128244 TFXI cl5 0,6/1kV black 3x35 mm2 8711401105592 N
128245 TFXI cl5 0,6/1kV black 3x50 mm2 8711401105622 N
128246 TFXI cl5 0,6/1kV black 3x70 mm2 8711401105639 N
128460 TFXI cl5 0,6/1kV black 3x95 mm2 8711401109170 N

128624 TFXI 0,6/1kV black 1x10 mm2 8711401116475 N


128625 TFXI 0,6/1kV black 1x16 mm2 8711401116482 N
128626 TFXI 0,6/1kV black 1x25 mm2 8711401116499 N
128627 TFXI 0,6/1kV black 1x35 mm2 8711401116512 N
128628 TFXI 0,6/1kV black 1x50 mm2 8711401116529 N
128629 TFXI 0,6/1kV black 1x70 mm2 8711401116543 N
128630 TFXI 0,6/1kV black 1x95 mm2 8711401116550 N
128631 TFXI 0,6/1kV black 1x120 mm2 8711401116567 N
128634 TFXI 0,6/1kV black 1x150 mm2 8711401116598 N
128632 TFXI 0,6/1kV black 1x185 mm2 8711401116574 N
128633 TFXI 0,6/1kV black 1x240 mm2 8711401116581 N
128571 TFXI 0,6/1kV black 1x400 mm2 8711401115850 N
125130 TFXI 0,6/1kV black 2x1,5 mm2 8711401104854 Y
125131 TFXI 0,6/1kV black 2x2,5 mm2 8711401021236 Y
125132 TFXI 0,6/1kV black 2x4 mm2 8711401021250 Y
125134 TFXI 0,6/1kV black 2x6 mm2 8711401021274 Y
125144 TFXI 0,6/1kV black 2x10 mm2 8711401021427 Y
125119 TFXI 0,6/1kV black 2x16 mm2 8711401104861 Y
126442 TFXI 0,6/1kV black 3G1,5 mm2 8711401039187 N
126444 TFXI 0,6/1kV black 3G2,5 mm2 8711401039255 N
125104 TFXI 0,6/1kV black 3x1,5 mm2 8711401020833 Y
125015 TFXI 0,6/1kV black 3x2,5 mm2 8711401019943 Y
125105 TFXI 0,6/1kV black 3x4 mm2 8711401020857 Y
125106 TFXI 0,6/1kV black 3x6 mm2 8711401020871 Y
327
Shipline Plus TFXI Power cable 0.6/1 kV
Halogen free shipcable

Part Description EAN No. Stock


number KDN Item
125107 TFXI 0,6/1kV black 3x10 mm2 8711401020888 Y
125109 TFXI 0,6/1kV black 3x16 mm2 8711401020901 Y
125088 TFXI 0,6/1kV black 3x25 mm2 8711401020666 Y
125110 TFXI 0,6/1kV black 3x35 mm2 8711401020918 Y
125089 TFXI 0,6/1kV black 3x50 mm2 8711401020673 Y
124994 TFXI 0,6/1kV black 3x70 mm2 8711401019721 Y
125090 TFXI 0,6/1kV black 3x95 mm2 8711401020680 Y
125112 TFXI 0,6/1kV black 3x120 mm2 8711401020932 N
125111 TFXI 0,6/1kV black 3x150 mm2 8711401020925 N
126443 TFXI 0,6/1kV black 4G1,5 mm2 8711401039231 N
126445 TFXI 0,6/1kV black 4G2,5 mm2 8711401039279 N
126446 TFXI 0,6/1kV black 4G6 mm2 8711401039293 N
125135 TFXI 0,6/1kV black 4x1,5 mm2 8711401034243 Y
125140 TFXI 0,6/1kV black 4x2,5 mm2 8711401021366 Y
125141 TFXI 0,6/1kV black 4x4 mm2 8711401021397 Y
125143 TFXI 0,6/1kV black 4x6 mm2 8711401021311 Y
125145 TFXI 0,6/1kV black 4x10 mm2 8711401021434 N
125146 TFXI 0,6/1kV black 4x16 mm2 8711401021465 Y
127385 TFXI 0,6/1kV black 5G1,5 mm2 8711401098979 N
127386 TFXI 0,6/1kV black 5G2,5 mm2 8711401098993 N
125441 TFXI 0,6/1kV black 5x1,5 mm2 8711401023933 N
125440 TFXI 0,6/1kV black 5x2,5 mm2 8711401023919 N
128639 TFXI 0,6/1kV black 6x1,5 mm2 8711401116659 N
128640 TFXI 0,6/1kV black 7x1,5 mm2 8711401116666 N
128647 TFXI 0,6/1kV black 8G1,5 mm2 8711401116741 N
128641 TFXI 0,6/1kV black 8x1,5 mm2 8711401116673 N
128642 TFXI 0,6/1kV black 10x1,5 mm2 8711401116680 N
128643 TFXI 0,6/1kV black 12x1,5 mm2 8711401116895 N
128644 TFXI 0,6/1kV black 16x1,5 mm2 8711401116703 N
128645 TFXI 0,6/1kV black 19x1,5 mm2 8711401116727 N
128646 TFXI 0,6/1kV black 24x1,5 mm2 8711401116734 N

Ambient temperature correction factors


Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75
Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

328
Shipline Plus TIOI(c) Instrumentation cable 250V
Braided halogen free shipcable

TIOI(c) 250V
XLPE/TCWB/SHF1

Max. conductor temp. : 90C


Nominal voltage : 250V

Application Standards applied


Design - IEC 60092-376
Armoured cable for fixed installations on ships Conductor - IEC 60228 class 2
where cable protection is required. Insulation - IEC 60092-351
For instrumentation and communication systems. Sheath - IEC 60092-359
Can be installed and operated both indoors and Flame retardant - IEC 60332-3-22 (cat A)
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Conductor Annealed stranded circular copper conductors

Insulation T Crosslinked polyethylene, XLPE

Numbered white cores twisted in pairs (two pair type may be built up
as a star quad). The pairs are twisted with different lay length to
Lay up
reduce mutual capacitance. One or more polyester tapes may be
applied

(c) Overall screen (polyester tape, tinned copper drain wire, metal coated
Screen
polyester tape). A polyester tape is applied over the screen

Inner covering I Flame retardant halogen free thermoplastic compound, SHF1

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} TIOI 250 V .. pair/triple/quad .. mm2


Marking text IEC60332-3-22 ShipLine {year of manufacture}
{length indication (meter)}
Outer sheath Grey
colour

329
Shipline Plus TIOI(c) Instrumentation cable 250V
Braided halogen free shipcable

Identification of elements

The pairs have the following number identification according to IEC 60092-376

Pair no. 1 core no. 1 and 2


Pair no. 2 core no. 3 and 4
Pair no. 3 core no. 5 and 6
Pair no. 4 etc.

The single triple is identified


with no 1, 2 and 3

1
The single quad cable has the
4 + 3
following identification
2

Range and dimensions


Elements Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
(pair) cross cross conductor thickness diameter sheath sheath approx. content
(triple) section section diameter (mm) thickness diameter approx.
(quad) (mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
1 pair 0.75 - 2.1 0.5 0.2 0.8 9.1 120 52
1 triple 0.75 - 2.1 0.5 0.2 0.8 9.4 135 62
1 quad 0.75 - 2.1 0.5 0.2 0.8 10.0 150 69
4 pair 0.75 - 2.1 0.5 0.3 0.9 14.2 290 147
7 pair 0.75 - 2.1 0.5 0.3 0.9 16.6 395 210
10 pair 0.75 - 2.1 0.5 0.3 1.0 19.6 510 264
14 pair 0.75 - 2.1 0.5 0.3 1.1 21.5 640 333
19 pair 0.75 - 2.1 0.5 0.3 1.1 23.7 785 419
24 pair 0.75 - 2.1 0.5 0.3 1.2 27.4 970 508

Electrical values
Type Capacitance Inductance Resistance
approx. Approx. at 20 oC
(nF/km) (mH/km) (Ohm/km)
Single pair/triple 0.75 mm2 70 0.60 26.0
Single quad 0.75 mm2 60 0.50 26.0
Multi pair/triple 0,75 75 0.60 26.0

330
Shipline Plus TIOI(c) Instrumentation cable 250V
Braided halogen free shipcable

Ordering information
Part Description EAN No. Stock
number KDN Item
125154 TIOI(c) 250V grey 1x2x0,75 mm2 8711401030665 Y
125156 TIOI(c) 250V grey 1x4x0,75 mm2 8711401021618 Y
127195 TIOI(c) 250V grey 1x3x0,75 mm2 8711401072146 N
125157 TIOI(c) 250V grey 4x2x0,75 mm2 8711401004284 Y
125159 TIOI(c) 250V grey 7x2x0,75 mm2 8711401030672 Y
125160 TIOI(c) 250V grey 10x2x0,75 mm2 8711401030726 Y
125161 TIOI(c) 250V grey 14x2x0,75 mm2 8711401030733 N
125162 TIOI(c) 250V grey 19x2x0,75 mm2 8711401030740 N
125163 TIOI(c) 250V grey 24x2x0,75 mm2 8711401030757 N

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

331
TFOI 12kV(2).doc
21.06.2006 14:02
Page 1 of 2

Shipline TFOI 6/10(12)kV MV Power cable


Flame retardant halogen-free medium
voltage (MV) power cable. Braided

TFOI 6/10(12) kV
XLPE/EPR/TCWB/PO

Operating temperature : 90C


Operating Voltage : 6/10(12) kV

Standards applied

Application IEC 60092-354 - Design


IEC 60228 class 2 - Conductor
IEC 60092-351 - Insulation
Armoured cable for fixed installation in ships where cable
protection is required. Medium Voltage power distribution. Can be IEC 60092-359 - Sheath
installed and operated both indoors and outdoors. IEC 60332-1 - Flame Retardant
IEC 60332-3-22 - Flame Retardant
IEC 600754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Annealed stranded circular copper, IEC 60228 class 2
Conductor screen Extruded semiconductive layer
semiconductive
Insulation T Crosslinked Polyethylene, IEC 60092-351 (HFXLPE)
Extruded semiconductive layer. A copper tape is applied as a metallic
Insulation screen
screen above the insulation screen. The thickness of the copper tape is 0,1
semicoductive
mm.
Cores are laid up together. Cores are identified by White, Black or Red
Lay up / Shielding
threads under and over the metallic screen on each conductor.
Inner covering F Flame retardant and halogen-free thermoplastic compound
Tape over bedding Additional tape may be applied
Armour/screen O Tinned copper wire braid
Tape over Additional tape may be applied
armour/screen
Outer sheath I Flame retardant halogen-free thermoplastic compound, SHF1
E.g. "meter" "year" DRAKA NORSK KABEL TFOI 6/10(12)KV 3 x 95/50
Marking text
mm2 IEC 60332-3-22 ShipLine
Outer sheath colour Red

www.drakaMOG.com
332
TFOI 12kV(2).doc
21.06.2006 14:02
Page 2 of 2

Shipline TFOI 6/10(12)kV MV Power cable


Range and dimensions
Cross Cross Thickness Diameter Weight Copper
Number Conductor Insulation Thickness Diameter Diameter
section section Outer outer of Cable content
of Diameter, Thickness, Bedding, bedding, Braid
core, screen, Sheath, sheath, Approx. Approx.
elements mm mm mm mm Wire, mm
mm mm mm mm (Kg/Km) (kg/km)
1 95 10 11.2 3.4 1 22.5 1 0.3 1.7 27 1 1640 1094
30.5
1 150 10 14.2 3.4 1 26 1 0.3 1.8 2220 1542
1.5
55.5
3 95 50 11.2 3.4 1.8 48.5 2 0.5 2.6 6060 3390
2.5
52.5
3 120 60 12.6 3.4 1.8 0.6 2.7 60 3 7270 4291
2.5

Ordering information
Part number Description EAN No. DNK EL No. KDN Part number EAN no. KDN
838504 TFOI 6/10(12)KV 1X 95/10mm2 7021528385045 - - -
838506 TFOI 6/10(12)KV 1X 150/10mm2 7021528385069 - - -
838525 TFOI 6/10(12)kV 3X 95/50mm 7021528385250 - - -
838526 TFOI 6/10(12)kV 3X 120/60mm 7021528385267 - - -

Electrical values power cables


Number Cross Cross Conductor Max. Max. Reactance Reactance Capacitans Current Short
of section section type 2 conductor conductor at 50Hz, at 60Hz, per phase, rating circuit
elements core, screen, resistance resistance Ohm/km Ohm/km nF/km IEC rating 1
mm mm at 20C, at 90C, 60092- second,
Ohm/km Ohm/km 352, Ampere
Ampere
1 95 10 SCC 0.193 0.246 0.119 0.143 300 293 16800
1 150 10 SCC 0.124 0.158 0.113 0.136 360 389 21000
3 95 50 SCC 0.193 0.246 0.091 0.109 300 205 4900
3 120 60 SCC 0.153 0.195 0.088 0.106 330 237 9800

Ambient temperature correction factors


Ambient Temp C 35 40 45 50 55 60 65 70 75 80
Rating factor 1.10 1.05 1.00 0.94 0.88 0.82 0.74 0.67 0.58 0.47

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Maximum Tensile Load During Minimum Installation
Installation Fixed Installed Installation Temperature
15 x D 9xD 50 N /mm -10C

www.drakaMOG.com
333
Shipline Plus TIOI Power cable 0.6/1 kV
Halogen free shipcable

TIOI 0.6/1kV
XLPE/SHF1/TCWB/SHF1

Max. conductor temp. : 90C


Nominal voltage : 0.6/1 kV

Application Standards applied


Design - IEC 60092-353
Armoured cable for fixed installations on ships Conductor - IEC 60228 class 2 and 5
where cable protection is required. Insulation - IEC 60092-351
For power, control and lighting systems. Sheath - IEC 60092-359
Can be installed and operated both indoors and Fire retardant - IEC 60332-3-22 (cat. A)
outdoors. Halogen Free - IEC 60754-1,2
Low smoke - IEC 61034-1,2

Construction
CODE
LETTER
Annealed stranded circular copper conductors, stranded acc IEC
Conductor
60228 class 2 or flexible acc IEC 60228 class 5
Insulation T Crosslinked polyethylene, XLPE

Cores laid up in one or more layers; in case of cables with more


Lay up than 5 cores one or more tapes may be applied over the laid up
cores
Inner sheath I Flame retardant halogen free thermoplastic compound SHF1

Armour/screen O Tinned copper wire braid

Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1

DRAKA {factory code} TIOI 0,6/1 kV ..x../.. mm2 IEC60332-3-22


Marking text
ShipLine Plus {year of manufacture} {length indication (meter)}
Outer sheath Black
colour

334
Shipline Plus TIOI Power cable 0.6/1 kV
Halogen free shipcable

Core identification

Single core Black


Two cores Blue - Brown
Three cores Brown - Black - Grey
Four cores Blue - Brown - Black - Grey
Five cores Blue - Brown - Black - Grey - Black
Multi core White with black numbers

with yellow/green (optional)


Two cores + earth (3G) Yellow/green - Blue - Brown
Three cores + earth (4G) Yellow/green - Brown - Black - Grey
Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey

Range and dimensions


Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
Class 5
1 120 10 17.4 1.2 0.3 1.1 23.8 1505 1197
3 35 16 9.95 0.9 0.3 1.2 29.0 1815 1120

Class 2
1 10 2.5 5.4 0.7 0.2 0.8 9.9 205 126
1 16 2.5 6.4 0.7 0.2 0.8 11.0 275 183
1 25 4 8.1 0.9 0.2 0.9 13.1 405 278
1 35 6 9.4 0.9 0.3 0.9 14.7 540 400
1 50 6 10.8 1.0 0.3 0.9 16.3 685 515
1 70 6 12.8 1.1 0.3 1.0 18.7 930 714
1 95 10 14.7 1.1 0.3 1.0 20.7 1205 958
1 120 10 16.5 1.2 0.3 1.1 22.8 1490 1198
1 150 16 18.4 1.4 0.3 1.1 24.9 1800 1457
1 185 16 20.7 1.6 0.3 1.2 27.4 2210 1806
1 240 16 23.4 1.7 0.3 1.2 30.4 2815 2333
1 300 25 26.0 1.8 0.4 1.3 33.9 3530 2952
1 400 25 29.3 2.0 0.4 1.4 37.9 4465 3745
2 1.5 4 3.0 0.7 0.2 0.8 11.3 200 72
2 2.5 4 3.5 0.7 0.2 0.9 12.4 255 96
2 4 6 4.0 0.7 0.3 0.9 13.9 345 158
2 6 6 4.5 0.7 0.3 0.9 15.2 425 202
2 10 10 5.4 0.7 0.3 1.0 16.9 560 287
2 16 16 6.4 0.7 0.3 1.0 19.7 805 450
2 25 16 8.1 0.9 0.3 1.1 23.0 1120 611
2 35 16 9.4 0.9 0.3 1.2 25.9 1405 777
3G 1.5 4 3.0 0.7 0.2 0.8 12.0 235 93
3G 2.5 4 3.5 0.7 0.2 0.9 13.0 290 125
3 1.5 4 3.0 0.7 0.2 0.8 12.0 235 93
3 2.5 4 3.5 0.7 0.2 0.9 13.0 290 125
3 4 6 4.0 0.7 0.3 0.9 14.5 390 198

335
Shipline Plus TIOI Power cable 0.6/1 kV
Halogen free shipcable

Conductors Conductor Screen Insulated Insulation Braid wires Outer Outer Weight Copper
cross cross conductor thickness diameter sheath sheath approx. content
section section diameter (mm) thickness diameter approx.
(mm2) (mm2) (mm) (mm) (mm) (mm) (kg/km) (kg/km)
3 6 6 4.5 0.7 0.3 0.9 15.9 485 254
3 10 10 5.4 0.7 0.3 1.0 17.9 665 376
3 16 16 6.4 0.7 0.3 1.0 20.7 950 593
3 25 16 8.1 0.9 0.3 1.1 24.5 1355 830
3 35 16 9.4 0.9 0.3 1.2 27.6 1740 1104
3 50 25 10.8 1.0 0.4 1.3 32.6 2425 1530
3 70 35 12.8 1.1 0.5 1.4 37.6 3355 2177
3 95 50 14.7 1.1 0.6 1.5 43.2 4570 3071
3 120 60 16.5 1.2 0.6 1.6 47.5 5680 3871
3 150 70 18.4 1.4 0.6 1.7 52.1 6780 4613
3 185 95 20.7 1.6 0.4 1.8 58.9 8680 5959
4G 1.5 4 3.0 0.7 0.2 0.9 12.8 265 108
4G 2.5 6 3.5 0.7 0.3 0.9 14.3 360 177
4 1.5 4 3.0 0.7 0.2 0.9 12.8 265 108
4 2.5 6 3.5 0.7 0.3 0.9 14.3 360 177
4 4 6 4.0 0.7 0.3 0.9 15.8 465 243
4 6 6 4.5 0.7 0.3 1.0 17.2 580 324
4 10 10 5.4 0.7 0.3 1.0 19.3 795 475
4 16 16 6.4 0.7 0.3 1.1 22.8 1155 737
4 25 16 8.1 0.9 0.3 1.2 26.7 1670 1174
4 35 16 9.4 0.9 0.3 1.2 30.0 2110 1410
4 50 25 10.8 1.0 0.4 1.4 35.9 3005 1978
4 70 35 12.8 1.1 0.4 1.5 41.3 4110 2777
4 95 50 14.7 1.1 0.6 1.6 47.6 5645 3934
5G 1.5 4 3.0 0.7 0.2 0.9 13.8 300 127
5G 2.5 6 3.5 0.7 0.3 0.9 15.5 420 208
5 1.5 4 3.0 0.7 0.2 0.9 13.8 300 127
5 2.5 6 3.5 0.7 0.3 0.9 15.5 420 208
6 1.5 6 3.0 0.7 0.3 0.9 14.6 335 174
6 2.5 6 3.5 0.7 0.3 0.9 16.1 423 236
7 1.5 6 3.0 0.7 0.3 0.9 14.6 345 188
7 2.5 6 3.5 0.7 0.3 0.9 16.1 445 257
8 1.5 6 3.0 0.7 0.3 0.9 15.9 400 211
10 1.5 10 3.0 0.7 0.3 1.0 17.9 470 254
12 1.5 10 3.0 0.7 0.3 1.0 18.6 525 284
16 1.5 10 3.0 0.7 0.3 1.0 20.3 640 357
19 1.5 10 3.0 0.7 0.3 1.1 21.6 725 400
24 1.5 10 3.0 0.7 0.3 1.1 24.8 920 494

336
Shipline Plus TIOI Power cable 0.6/1 kV
Halogen free shipcable

Electrical values
Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
Class 5
1 120 10 SCC 0.161 0.2053 0.089 0.107 339 17160
3 35 16 SCC 0.554 0.7064 0.076 0.092 110 5005

Class 2
1 10 2.5 SCC 1.83 2.33 0.123 0.147 72 1430
1 16 2.5 SCC 1.15 1.47 0.114 0.137 96 2285
1 25 4 SCC 0.727 0.927 0.110 0.132 127 3575
1 35 6 SCC 0.524 0.669 0.106 0.128 157 5005
1 50 6 SCC 0.387 0.494 0.101 0.121 196 7150
1 70 6 SCC 0.268 0.343 0.097 0.117 242 10010
1 95 10 SCC 0.193 0.248 0.093 0.112 293 13585
1 120 10 SCC 0.153 0.198 0.091 0.109 339 17160
1 150 16 SCC 0.124 0.162 0.090 0.109 389 21450
1 185 16 SCC 0.0991 0.131 0.090 0.107 444 26455
1 240 16 SCC 0.0754 0.102 0.087 0.104 522 34320
1 300 25 SCC 0.0601 0.0766 0.087 0.104 601 42900
1 400 25 SCC 0.047 0.0685 0.086 0.103 670 57200
2 1.5 4 SCC 12.1 15.4 0.104 0.125 20 210
2 2.5 4 SCC 7.41 9.45 0.098 0.118 26 355
2 4 6 SCC 4.61 5.88 0.092 0.110 34 570
2 6 6 SCC 3.08 3.93 0.088 0.106 44 855
2 10 10 SCC 1.83 2.33 0.084 0.100 61 1430
2 16 16 SCC 1.15 1.47 0.080 0.096 82 2285
2 25 16 SCC 0.727 0.927 0.080 0.097 108 3575
2 35 16 SCC 0.524 0.669 0.078 0.093 133 5005
3G 1.5 4 SCC 12.1 15.4 0.104 0.125 20 210
3G 2.5 4 SCC 7.41 9.45 0.098 0.118 26 355
3 1.5 4 SCC 12.1 15.4 0.104 0.125 16 210
3 2.5 4 SCC 7.41 9.45 0.098 0.118 21 355
3 4 6 SCC 4.61 5.88 0.092 0.110 28 570
3 6 6 SCC 3.08 3.93 0.088 0.106 36 855
3 10 10 SCC 1.83 2.33 0.084 0.100 50 1430
3 16 16 SCC 1.15 1.47 0.080 0.096 67 2285
3 25 16 SCC 0.727 0.927 0.080 0.097 89 3575
3 35 16 SCC 0.524 0.669 0.078 0.093 110 5005
3 50 25 SCC 0.387 0.494 0.074 0.089 137 7150
3 70 35 SCC 0.268 0.343 0.073 0.088 169 10010
3 95 50 SCC 0.193 0.248 0.072 0.086 205 13585
3 120 60 SCC 0.153 0.198 0.070 0.084 237 17160
3 150 70 SCC 0.124 0.162 0.071 0.085 272 21450
3 185 95 SCC 0.0991 0.131 0.071 0.086 311 26455
4G 1.5 4 SCC 12.1 15.4 0.112 0.134 16 210
4G 2.5 6 SCC 7.41 9.45 0.105 0.126 21 355
4 1.5 4 SCC 12.1 15.4 0.112 0.134 14 855
4 2.5 6 SCC 7.41 9.45 0.105 0.126 18 210
4 4 6 SCC 4.61 5.88 0.099 0.119 25 355
4 6 6 SCC 3.08 3.93 0.095 0.114 32.5 570
4 10 10 SCC 1.83 2.33 0.091 0.109 45 855

337
Shipline Plus TIOI Power cable 0.6/1 kV
Halogen free shipcable

Conductors Conductor Screen Conductor Resistance Resistance Reactance Reactance Current Short circuit
cross cross type at 20 oC at 90 oC at 50Hz at 60Hz rating rating
section section DC 50 Hz IEC60092-352 1sec
(mm2) (mm2) (Ohm/km) (Ohm/km) (Ohm/km) (Ohm/km) (A) (A)
4 16 16 SCC 1.15 1.47 0.087 0.105 60 1430
4 25 16 SCC 0.727 0.927 0.088 0.105 80 3575
4 35 16 SCC 0.524 0.669 0.085 0.102 98.5 5005
4 50 25 SCC 0.387 0.494 0.082 0.098 123 7150
4 70 35 SCC 0.268 0.343 0.080 0.097 152 10010
4 95 50 SCC 0.193 0.248 0.079 0.095 184.5 13585
5G 1.5 4 SCC 12.1 15.4 0.114 0.137 14 2285
5G 2.5 6 SCC 7.41 9.45 0.108 0.130 18 210
5 1.5 4 SCC 12.1 15.4 0.114 0.137 13 355
5 2.5 6 SCC 7.41 9.45 0.108 0.130 16.5 210
6 1.5 6 SCC 12.1 15.4 0.104 0.125 12.5 355
6 2.5 6 SCC 7.41 9.45 0.098 0.118 15.5 355
7 1.5 6 SCC 12.1 15.4 0.104 0.125 12 210
7 2.5 6 SCC 7.41 9.45 0.098 0.118 15 355
8 1.5 6 SCC 12.1 15.4 0.104 0.125 11.5 210
10 1.5 10 SCC 12.1 15.4 0.104 0.125 10.5 210
12 1.5 10 SCC 12.1 15.4 0.104 0.125 10 210
16 1.5 10 SCC 12.1 15.4 0.104 0.125 9 210
19 1.5 10 SCC 12.1 15.4 0.104 0.125 8.5 210
24 1.5 10 SCC 12.1 15.4 0.104 0.125 7.5 210

SCC = Stranded Circular Conductor

Ordering information
Part Description EAN No. Stock
number KDN Item
128637 TIOI cl5 0,6/1kV black 1x120/10 mm2 8711401106536 N
128223 TIOI cl5 0,6/1kV black 3x35/16 mm2 8711401105301 N

125043 TIOI 0,6/1kV black 1x10/2,5 mm2 8711401020130 N


125044 TIOI 0,6/1kV black 1x16/2,5 mm2 8711401020154 Y
125047 TIOI 0,6/1kV black 1x25/4 mm2 8711401020161 N
125048 TIOI 0,6/1kV black 1x35/6 mm2 8711401020178 Y
125050 TIOI 0,6/1kV black 1x50/6 mm2 8711401020185 Y
125058 TIOI 0,6/1kV black 1x70/6 mm2 8711401020253 N
125059 TIOI 0,6/1kV black 1x95/10 mm2 8711401020260 N
125051 TIOI 0,6/1kV black 1x120/10 mm2 8711401020192 N
125053 TIOI 0,6/1kV black 1x150/16 mm2 8711401020208 N
125055 TIOI 0,6/1kV black 1x185/16 mm2 8711401020215 N
125056 TIOI 0,6/1kV black 1x240/16 mm2 8711401020222 N
127296 TIOI 0,6/1kV black 1x300/25 mm2 8711401083142 N
128714 TIOI 0,6/1kV black 1x400/25 mm2 8711401119421 N
125061 TIOI 0,6/1kV black 2x1,5/4 mm2 8711401020321 Y
125078 TIOI 0,6/1kV black 2x2,5/4 mm2 8711401119346 Y
125080 TIOI 0,6/1kV black 2x4/6 mm2 8711401119353 N
125081 TIOI 0,6/1kV black 2x6/6 mm2 8711401020499 N
125034 TIOI 0,6/1kV black 2x10/10 mm2 8711401020055 N
125035 TIOI 0,6/1kV black 2x16/16 mm2 8711401020062 N
127321 TIOI 0,6/1kV black 2x25/16 mm2 8711401093479 N
127328 TIOI 0,6/1kV black 2x35/16 mm2 8711401093493 N
127379 TIOI 0,6/1kV black 3G1,5/4 mm2 8711401095121 N
127380 TIOI 0,6/1kV black 3G2,5/4 mm2 8711401095145 N
125020 TIOI 0,6/1kV black 3x1,5/4 mm2 8711401020390 Y
125016 TIOI 0,6/1kV black 3x2,5/4 mm2 8711401119339 Y
125021 TIOI 0,6/1kV black 3x4/6 mm2 8711401020413 Y
125022 TIOI 0,6/1kV black 3x6/6 mm2 8711401119322 Y
125019 TIOI 0,6/1kV black 3x10 mm2 8711401019981 Y
125024 TIOI 0,6/1kV black 3x16 mm2 8711401119308 Y
125023 TIOI 0,6/1kV black 3x25 mm2 8711401019998 Y

338
Shipline Plus TIOI Power cable 0.6/1 kV
Halogen free shipcable

Part Description EAN No. Stock


number KDN Item
125069 TIOI 0,6/1kV black 3x35 mm2 8711401119292 Y
125067 TIOI 0,6/1kV black 3x50 mm2 8711401119285 Y
124995 TIOI 0,6/1kV black 3x70 mm2 8711401019745 N
125032 TIOI 0,6/1kV black 3x95 mm2 8711401020048 Y
125026 TIOI 0,6/1kV black 3x120 mm2 8711401119278 N
125030 TIOI 0,6/1kV black 3x150 mm2 8711401020024 N
128707 TIOI 0,6/1kV black 3x185 mm2 8711401119261 N
127381 TIOI 0,6/1kV black 4G1,5 mm2 8711401095169 N
127382 TIOI 0,6/1kV black 4G2,5 mm2 8711401095183 N
125082 TIOI 0,6/1kV black 4x1,5 mm2 8711401020512 Y
125092 TIOI 0,6/1kV black 4x2,5 mm2 8711401119360 Y
125094 TIOI 0,6/1kV black 4x4 mm2 8711401020734 N
125095 TIOI 0,6/1kV black 4x6 mm2 8711401020758 Y
125036 TIOI 0,6/1kV black 4x10 mm2 8711401020086 Y
125040 TIOI 0,6/1kV black 4x16 mm2 8711401020093 Y
125041 TIOI 0,6/1kV black 4x25 mm2 8711401020116 Y
128022 TIOI 0,6/1kV black 4x35 mm2 8711401102638 N
128024 TIOI 0,6/1kV black 4x50 mm2 8711401102768 N
128023 TIOI 0,6/1kV black 4x70 mm2 8711401102720 N
128025 TIOI 0,6/1kV black 4x95 mm2 8711401102782 N
127383 TIOI 0,6/1kV black 5G1,5 mm2 8711401097729 N
127384 TIOI 0,6/1kV black 5G2,5 mm2 8711401098955 N
125407 TIOI 0,6/1kV black 5x1,5 mm2 8711401023537 Y
125408 TIOI 0,6/1kV black 5x2,5 mm2 8711401023551 N
125096 TIOI 0,6/1kV black 6x1,5 mm2 8711401020772 Y
125100 TIOI 0,6/1kV black 6x2,5 mm2 8711401020819 N
125099 TIOI 0,6/1kV black 7x1,5 mm2 8711401020796 Y
125117 TIOI 0,6/1kV black 7x2,5 mm2 8711401020956 N
125118 TIOI 0,6/1kV black 8x1,5 mm2 8711401020970 Y
125122 TIOI 0,6/1kV black 10x1,5 mm2 8711401021038 Y
125123 TIOI 0,6/1kV black 12x1,5 mm2 8711401021090 Y
125126 TIOI 0,6/1kV black 16x1,5 mm2 8711401021144 Y
125127 TIOI 0,6/1kV black 19x1,5 mm2 8711401021168 Y
125128 TIOI 0,6/1kV black 24x1,5 mm2 8711401021175 N

Ambient temperature correction factors


Ambient temp. C 25 30 35 40 45 50 55 60 65 70 75
Rating factor 1.22 1.17 1.12 1.06 1.00 0.94 0.87 0.79 0.71 0.61 0.50

Installation recommendations
Minimum bending radius Minimum bending radius Maximum tensile load Minimum installation
during installation fixed installed during installation temperature
8xD 6xD 50 N * total cross section -20 C
conductors

Subject to change without notice

339
Marine, Oil & Gas International
BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable
Fire resistant, Flame retardant halogen-free
power cable. Enhanced oil-resistance.

BFCU 0.6/1kV

Operating temperature : 90C


Operating Voltage : 0.6/1kV

Application Standards applied


Armoured cable for fixed installation for power, BS7917/BS6883/UKOOA - Design
control or lighting in both EX and safe areas, BS6360 class 2 - Conductor
emergency and critical systems where there is a BS7655 section 1.2 - Insulation
requirement for fire resistant cables.
BS7655 section 2.6 - Sheath
Enhanced MUD resistant version also available for use IEC 60332-1 &3-22 - Flame Retardant
in areas exposed to mud and drilling / cleaning fluids, IEC60331-21 - Fire Resistant
meeting the mud resistance requirement in NEK 606. IEC60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned stranded circular copper, BS 6360, class 2

Insulation B Mica glass tape / EP-rubber, GP4 to BS 7655: section 1.2

Lay up / Shielding Cores laid up in concentric layers

Inner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compound
Tape over inner PET tape + rubberized Polyamide tape
covering
Armour/screen C Galvanized steel wire braid
Tape over armour/ PET tape + rubberised Polyamide tape
screen
U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound
Outer sheath
(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "BFCU" "UKOOA code" "600/1000V" "number
of cores" "conductor size" "BS7917" "IEC60331-21 IEC60332-3-22" (marking
Marking text
may differ on cable actually supplied)

Outer sheath colour Black

Core identification
All cores are offwhite with black numbers No 1,2,3.

340
Marine, Oil & Gas International
BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable

Range and dimensions


Approx
Thickness Thickness Approx Weight of Copper
Cross Conductor Insulation Diameter Diameter
Number of Inner Outer Overall Cable content
section Diameter, Thickness, Inner Braid Wire,
cores Sheath, Sheath, Diameter, Approx. Approx.
core, mm mm mm Sheath, mm
mm mm mm (Kg/Km) (kg/km)
mm
2 2.5 2.0 0.8 1.1 10 0.3 1.2 14 350 46
3 1.5 1.6 0.8 1.1 10 0.3 1.2 14 340 42
3 2.5 2.0 0.8 1.1 10.5 0.3 1.3 15 410 69
4 1.5 1.6 0.8 1.1 11 0.3 1.3 15 400 56
4 2.5 2.0 0.8 1.1 11.5 0.3 1.3 16 450 92
7 2.5 2.0 0.8 1.2 14 0.3 1.4 18.5 620 161
12 2.5 2.0 0.8 1.4 19 0.3 1.6 24 960 275
27 2.5 2.0 0.8 1.7 27.5 0.45 1.9 33.5 1900 618
19 2.5 2.0 0.8 1.5 22.5 0.3 1.7 27.5 1360 435
4 70 10.85 1.4 2.1 38 0.45 2.4 45 4650 2484
3 4 2.55 1.0 1.2 13 0.3 1.3 17 540 110
2 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 295 28
12 1.5 1.6 0.8 1.3 17.5 0.3 1.5 22 770 167
3 6 3.15 1.0 1.2 14.5 0.3 1.4 18.5 650 164
2 4 2.55 1.0 1.2 12.5 0.3 1.3 16.5 470 74
3 10 4.05 1.0 1.3 16.5 0.3 1.5 21 840 271
2 10 4.05 1.0 1.3 15.5 0.3 1.4 20 710 181
3 25 6.45 1.2 1.6 23.5 0.3 1.8 28.5 1710 688
2 6 3.15 1.0 1.2 13.5 0.3 1.4 18 570 109
2 16 5.15 1.0 1.4 18 0.3 1.5 22.5 780 289
4 6 3.15 1.0 1.3 16 0.3 1.5 20.5 790 218
4 35 7.65 1.2 1.8 29 0.45 2 35 2700 1236
2 35 7.65 1.2 1.6 24.5 0.3 1.8 29.5 1740 618
3 35 7.65 1.2 1.7 26 0.45 1.9 32 2210 927
3 16 5.15 1.0 1.4 19 0.3 1.6 24 1160 434
3 50 9.0 1.4 1.8 30.5 0.45 2 36.5 2890 1293
3 70 10.85 1.4 2 34.5 0.45 2.2 41 3810 1863
4 4 2.55 1.0 1.2 14.5 0.3 1.4 18.5 630 147
3 95 12.60 1.6 2.2 39.5 0.45 2.4 46.5 4950 2513
7 1.5 1.6 0.8 1.2 13 0.3 1.3 17 520 98

341
Marine, Oil & Gas International
BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable
Ordering information
Part number Description Sheath Colour Design standard UKOOA Code

840073 BFCU 0.6/1kV 2X 2.5mm BLACK BS 7917 : 1999 YD203


840074 BFCU 0.6/1kV 3X 1.5mm BLACK BS 7917 : 1999 YD302
840075 BFCU 0.6/1kV 3X 2.5mm BLACK BS 7917 : 1999 YD303
840076 BFCU 0.6/1kV 4X 1.5mm BLACK BS 7917 : 1999 YD402
840077 BFCU 0.6/1kV 4X 2.5mm BLACK BS 7917 : 1999 YD403
840078 BFCU 0.6/1kV 7X 2.5mm BLACK BS 7917 : 1999 YD703
840079 BFCU 0.6/1kV 12X 2.5mm BLACK BS 7917 : 1999 YDA03
840108 BFCU 0.6/1kV 27X 2.5mm BLACK BS 6883 : 1991 YDC03
840136 BFCU 0.6/1kV 19X 2.5mm BLACK BS 7917 : 1999 YDB03
840151 BFCU 0,6/1kV 4X 70 MM2 BLACK BS 7917 : 1999 YD470
840153 BFCU 0.6/1kV 3X 4mm BLACK BS 7917 : 1999 YD304
840162 BFCU 0.6/1kV 2X 1.5mm BLACK BS 7917 : 1999 YD202
840165 BFCU 0,6/1kV 12X 1,5mm2 BLACK BS 7917 : 1999 YDA02
840167 BFCU 0.6/1kV 3X 6mm BLACK BS 7917 : 1999 YD306
840230 BFCU 0.6/1kV 2X 4mm BLACK BS 7917 : 1999 YD204
840233 BFCU 0.6/1kV 3X 10mm BLACK BS 7917 : 1999 YD310
840243 BFCU 0,6/1kV 2X 10MM2 BLACK BS 7917 : 1999 YD210
840248 BFCU 0.6/1kV 3X 25mm BLACK BS 7917 : 1999 YD325
840249 BFCU 0.6/1kV 2X 6mm BLACK BS 7917 : 1999 YD206
840250 BFCU 0,6/1kV 2X 16 MM2 BLACK BS 7917 : 1999 YD216
840257 BFCU 0.6/1kV 4X 6mm BLACK BS 7917 : 1999 YD406
840259 BFCU 0.6/1kV 4X 35mm BLACK BS 7917 : 1999 YD435
840270 BFCU 0.6/1kV 2X 35mm BLACK BS 7917 : 1999 YD235
840273 BFCU 0.6/1kV 3X 35mm BLACK BS 7917 : 1999 YD335
840297 BFCU 0.6/1kV 3X 16mm BLACK BS 7917 : 1999 YD316
840298 BFCU 0.6/1kV 3X 50mm BLACK BS 7917 : 1999 YD350
840299 BFCU 0.6/1kV 3X 70mm BLACK BS 7917 : 1999 YD370
840308 BFCU 0.6/1kV 4X 4mm BLACK BS 7917 : 1999 YD404
840309 BFCU 0.6/1kV 3X 95mm BLACK BS 7917 : 1999 YD370
840310 BFCU 0.6/1kV 7X 1.5mm BLACK BS 7917 : 1999 YD702

342
Marine, Oil & Gas International
BFCU 0.6/1KV Fire resistant Power, Control or Lighting cable
Electrical values
Number of Cross section Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
cores core, mm resistance at resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352 rating 1
20C, Ohm/km 90C, Ohm/km Table B.4, second,
Ampere Ampere
2 2.5 7.56 9.64 0.101 0.121 26 350
3 1.5 12.2 15.6 0.108 0.130 16 210
3 2.5 7.56 9.64 0.101 0.121 21 350
4 1.5 12.2 15.6 0.108 0.130 16 210
4 2.5 7.56 9.64 0.101 0.121 21 350
7 2.5 7.56 9.64 0.101 0.121 15.5 350
12 2.5 7.56 9.64 0.101 0.121 13 350
27 2.5 7.56 9.64 0.101 0.121 10 350
19 2.5 7.56 9.64 0.101 0.121 11 350
4 70 0.27 0.344 0.075 0.090 169 9800
3 4 4.7 5.99 0.100 0.120 28 560
2 1.5 12.2 15.6 0.108 0.130 20 210
12 1.5 12.2 15.6 0.108 0.130 10 210
3 6 3.11 3.97 0.094 0.112 36 840
2 4 4.7 5.99 0.100 0.120 34 560
3 10 1.84 2.35 0.088 0.105 50 1400
2 10 1.84 2.35 0.088 0.105 61 1400
3 25 0.734 0.936 0.081 0.097 89 3500
2 6 3.11 3.97 0.094 0.112 44 840
2 16 1.16 1.48 0.082 0.099 80 2240
4 6 3.11 3.97 0.094 0.112 36 840
4 35 0.529 0.675 0.078 0.094 110 4900
2 35 0.529 0.675 0.078 0.094 133 4900
3 35 0.529 0.675 0.078 0.094 110 4900
3 16 1.16 1.48 0.082 0.099 67 2240
3 50 0.391 0.499 0.078 0.093 137 7000
3 70 0.27 0.344 0.075 0.090 169 9800
4 4 4.7 5.99 0.100 0.120 28 560
3 95 0.195 0.249 0.075 0.090 205 13300
7 1.5 12.2 15.6 0.108 0.130 12 210

Ambient temperature correction factors


Ambient
35 40 45 50 55 60 65 70 75 80
Temp C
Rating
1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47
factor

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation
Installation Installed Installation Temperature
OD < 25 mm - 4 x D, OD > 25
8xD 50 N /mm -20C
mm - 6 x D 343
Marine, Oil & Gas International
BFCU(C) 250V, Fire Resistant, Collective screened instrumentation
Fire resistant, Flame retardant halogen-free
instrumentation cable. Enhanced oil-resistance.

BFCU(C) 250V

Operating temperature : 90C


Operating Voltage : 250V

Application Standards applied


Fixed installation for instrumentation, communication, BS7917/BS6883/UKOOA - Design
control and alarm systems in both EX and safe areas, BS6360 class 2 or 5 - Conductor
emergency and critical systems where there is a BS7655 section 1.2 - Insulation
requirement for fire resistant cables..
BS7655 section 2.6 - Sheath
Enhanced MUD resistant version also available for use IEC 60332-1 & 3-22 - Flame Retardant
in areas exposed to mud and drilling / cleaning fluids, IEC60331-21 - Fire Resistant
meeting the mud resistance requirement in NEK 606. IEC60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
Conductor
Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)
Insulation B Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2
Colour coded cores twisted together to form a pair, triple or quad, wrapped
with polyester tape. Pairs, triples or quads are laid up, collectively screened
Pair/Triple/Quad
with aluminium backed polyester tape with tinned copper drain wire. Pairs,
twisting
triples, or quads are identified by numbers printed directly on the insulated
conductors.
Inner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compound
Tape over inner PET tape + rubberized Polyamide tape
covering
Armour/screen C Galvanized steel wire braid
Tape over armour/ PET tape + rubberised Polyamide tape
screen
U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound
Outer sheath
(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "BFCU(C)" "UKOOA code" "150/250V"
Marking text "number of pair, triples or quads" "conductor size" "BS7917" IEC60331-21
"IEC60332-3-22" (marking may differ on cable actually supplied)

Outer sheath colour Grey or Blue

Core identification
Pair - BlackWhite, numbered 1-1, 2-2, 3-3
Triple BlackWhiteRed, numbered 1-1-1, 2-2-2, 3-3-3
Quad BlackWhiteRedBlue, numbered 1-1-1-1, 2-2-2-2 ..

Each core is identified by contrasting numerals & words repeated


344
along the whole length of the cable.
Marine, Oil & Gas International
BFCU(C) 250V, Fire Resistant, Collective screened instrumentation
Range and dimensions

Approx
Thickness Thickness Approx Weight of Copper
Number No of Cross Conductor Insulation Diameter Diameter
Inner Outer Overall Cable content
of cores in section Diameter, Thickness Inner Braid
Sheath, Sheath, Diameter Approx. Approx.
elements element core, mm mm mm Sheath, Wire, mm
mm mm mm (Kg/Km) (kg/km)
mm

3 2 0.75 1.15 0.8 1.2 13 0.3 1.4 17.5 460 45


7 2 0.75 1.15 0.8 1.4 17.5 0.3 1.5 22 740 98
12 2 0.75 1.15 0.8 1.6 22.5 0.3 1.7 27.5 1120 164
19 2 0.75 1.15 0.8 1.7 26 0.45 1.9 32 1600 258
27 2 0.75 1.15 0.8 1.9 31 0.45 2.2 37.5 2190 360
3 2 0.75 1.15 0.8 1.2 13 0.3 1.4 17.5 460 45
7 2 0.75 1.15 0.8 1.4 17.5 0.3 1.5 22 740 98
12 2 0.75 1.15 0.8 1.6 22.5 0.3 1.7 27.5 1120 164
19 2 0.75 1.15 0.8 1.7 26 0.45 1.9 32 1600 258
27 2 0.75 1.15 0.8 1.9 31 0.45 2.2 37.5 2190 360
3 2 1 1.3 0.8 1.2 13.5 0.3 1.4 18 490 58
2 2 1.5 1.6 0.8 1.2 13.5 0.3 1.4 18 470 57
20 2 0.75 1.15 0.8 1.8 27 0.45 2 33 1720 271
3 2 1.5 1.6 0.8 1.3 14.5 0.3 1.4 19 570 82
7 2 1.5 1.6 0.8 1.4 19.5 0.3 1.6 24 920 183
12 2 1.5 1.6 0.8 1.7 26 0.45 1.9 31.5 1560 310
20 2 0.75 1.15 0.8 1.8 27 0.45 2 33 1720 271
20 2 1.5 1.6 0.8 1.9 31 0.45 2.2 37.5 2260 511
27 2 1.5 1.6 0.8 2.1 35.5 0.45 2.4 42 2820 688
7 3 0.75 1.15 0.8 1.4 19.5 0.3 1.6 24.5 930 144
12 3 0.75 1.15 0.8 1.7 26 0.3 1.9 31.5 1450 245
3 2 2.5 2 0.8 1.3 16 0.3 1.5 20.5 680 147
12 2 2.5 2 0.8 1.8 28.5 0.45 2 34.5 1960 565
2 2 0.75 1.15 0.8 1.2 12 0.3 1.3 16.5 390 31
3 3 0.75 1.15 0.8 1.3 15 0.3 1.4 19 550 65
7 3 1.5 1.6 0.8 1.5 22 0.3 1.7 27 1180 271
12 3 1.5 1.6 0.8 1.8 29.5 0.45 2 35.5 2020 462
7 2 1.5 1.6 0.8 1.4 19.5 0.3 1.6 24 920 183
20 2 1.5 1.6 0.8 1.9 31 0.45 2.2 37.5 2260 511
2 2 1.5 1.6 0.8 1.2 13.5 0.8 0.3 1.4 18 0.8 470 57
3 2 1.5 1.6 0.8 1.3 14.5 0.8 0.3 1.4 19 0.8 570 82
5 2 1.5 1.6 0.8 1.4 18 0.8 0.3 1.6 22.5 1 780 133
5 2 1.5 1.6 0.8 1.4 18 0.8 0.3 1.6 22.5 1 780 133
7 2 1.5 1.6 0.8 1.4 19.5 0.8 0.3 1.6 24 1 920 183
2 2 0.75 1.15 0.8 1.2 12 0.8 0.3 1.3 16.5 0.8 390 31
3 2 1 1.3 0.8 1.2 13.5 0.8 0.3 1.4 18 0.8 490 58
5 2 0.75 1.15 0.8 1.3 15.5 0.8 0.3 1.5 20 1 620 71
5 2 0.75 1.15 0.8 1.3 15.5 0.8 0.3 1.5 20 1 620 71
12 2 1.5 1.6 0.8 1.7 345
26 1 0.45 1.9 31.5 1.5 1560 310
Marine, Oil & Gas International
BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Electrical values
Insulation
Resistance at 20
Capacitance, Inductance, L/R ratio, resistance
Type C, max. (Ohm/
approx. (nF/km) approx, (mH/km) (microH/Ohm) (Minimum MOhm
km)
x km)
Unshielded pair 0,75 mm 80 0,75 26,7 14 940
Unshielded triple 0,75 mm 80 0,75 26,7 14 940
Unshielded pair 1,0 mm 85 0,73 20,0 18 840
Unshielded triple 1,0 mm 85 0,73 20,0 18 840
Unshielded pair 1,5 mm 90 0,68 13,7 24,8 730
Unshielded triple 1,5 mm 90 0,68 13,7 24,8 730
Unshielded pair 2,5 mm 90 0,70 7,56 46,3 620
Unshielded triple 2,5 mm 90 0,70 7,56 46,3 620

Ordering information
Part number Description Sheath Colour Design standard UKOOA Code

840011 BFCU(C) 250V 3PAIR 0.75mm GREY BS 7917 : 1999 GNH00


840012 BFCU(C) 250V 7PAIR 0.75mm GREY BS 7917 : 1999 GNJ00
840013 BFCU(C) 250V 12PAIR 0.75mm GREY BS 7917 : 1999 GNK00
840014 BFCU(C) 250V 19PAIR 0.75mm GREY BS 6883 : 1991 -
840015 BFCU(C) 250V 27PAIR 0.75mm GREY BS 7917 : 1999 GNM00
840031 BFCU(C) 250V 3PAIR 0.75mm BLUE BS 7917 : 1999 GLH00
840032 BFCU(C) 250V 7PAIR 0.75mm BLUE BS 7917 : 1999 GLJ00
840033 BFCU(C) 250V 12PAIR 0.75mm BLUE BS 7917 : 1999 GLK00
840034 BFCU(C) 250V 19PAIR 0.75mm BLUE BS 6883 : 1991 -
840035 BFCU(C) 250V 27PAIR 0.75mm BLUE BS 7917 : 1999 GLM00
840090 BFCU(C) 250V 3PAIR 1mm BLUE BS 7917 : 1999 GLH01
840111 BFCU(C) 250V 2PAIR 1.5mm BLUE BS 6883 : 1991 -
840124 BFCU(C) 250V 20PAIR 0.75mm GREY BS 7917 : 1999 GNL00

840132 BFCU(C) 250V 3PAIR 1.5mm GREY BS 6883 : 1991 GNH02


840133 BFCU(C) 250V 7PAIR 1.5mm GREY BS 6883 : 1991 GNJ02
840134 BFCU(C) 250V 12PAIR 1.5mm GREY BS 6883 : 1991 GNK02
840144 BFCU(C) 250V 20PAIR 0.75mm BLUE BS 7917 : 1999 GLL00
840171 BFCU(C) 250V 20PAIR 1.5mm GREY BS 6883 : 1991 GNL02
840172 BFCU(C) 250V 27PAIR 1.5mm GREY BS 6883 : 1991 GNM02
840173 BFCU(C) 250V 7TRIP 0.75mm GREY BS 7917 : 1999 GNT00
840174 BFCU(C) 250V 12TRIP 0.75mm GREY BS 7917 : 1999 GNU00

346
Marine, Oil & Gas International
BFCU(C) 250V, Fire Resistant, Collective screened instrumentation

Part number Description Sheath Colour Design standard UKOOA Code

840203 BFCU(C) 250V 3PAIR 2.5mm GREY BS 6883 : 1991 GNH03


840205 BFCU(C) 250V 12PAIR 2.5mm GREY BS 6883 : 1991 GNK03
840220 BFCU(C) 250V 2PAIR 0.75mm GREY BS 6883 : 1991 -
840255 BFCU(C) 250V 3TRIP 0.75mm GREY BS 7917 : 1999 GNS00
840260 BFCU(C) 250V 7TRIP 1.5mm GREY BS 6883 : 1991 GNT02
840261 BFCU(C) 250V 12TRIP 1.5mm GREY BS 6883 : 1991 GNU02
840265 BFCU(C) 250V 7PAIR 1.5mm BLUE BS 6883 : 1991 GLJ02
840266 BFCU(C) 250V 20PAIR 1.5mm BLUE BS 6883 : 1991 GLL02
840285 BFCU(C) 250V 2PAIR 1.5mm GREY BS 6883 : 1991 -
840286 BFCU(C) 250V 3PAIR 1.5mm BLUE BS 6883 : 1991 GLH02
840287 BFCU(C) 250V 5PAIR 1.5mm GREY BS 6883 : 1991 -
840288 BFCU(C) 250V 5PAIR 1.5mm BLUE BS 6883 : 1991 -
840289 BFCU(C) 250V 7PAIR 1.5mm BLUE BS 6883 : 1991 GLJ02
840317 BFCU(C) 250V 2PAIR 0.75mm BLUE BS 6883 : 1991 -
840318 BFCU(C) 250V 3PAIR 1mm GREY BS 7917 : 1999 GNH01
840319 BFCU(C) 250V 5PAIR 0.75mm GREY BS 6883 : 1991 -
840320 BFCU(C) 250V 5PAIR 0.75mm BLUE BS 6883 : 1991 -
840321 BFCU(C) 250V 12PAIR 1.5mm BLUE BS 6883 : 1991 GLK02

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation
Installation Installed Installation Temperature
10 x D 8xD 50 N /mm -20C

347
Marine, Oil & Gas International
BFCU(I) 250V, Fire Resistant, Individual screened instrumentation
Fire resistant, Flame retardant halogen-free
instrumentation cable. Enhanced oil-resistance.

BFCU(I) 250V

Operating temperature : 90C


Operating Voltage : 250V

Application Standards applied


Fixed installation for instrumentation, communication, BS7917/6883/UKOOA - Design
control and alarm systems in both EX and safe areas, BS6360 class 2 or 5 - Conductor
emergency and critical systems where there is a BS7655 section 1.2 - Insulation
requirement for fire resistant cables..
BS7655 section 2.6 - Sheath
Enhanced MUD resistant version also available for use IEC 60332-1 & 3-22 - Flame Retardant
in areas exposed to mud and drilling / cleaning fluids, IEC60331-21 - Fire Resistant
meeting the mud resistance requirement in NEK 606. IEC60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke
Construction
Code
Letter
Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
Conductor
Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)
Insulation B Mica Glass Tape / EP-rubber, GP4 to BS 7655: section 1.2
Colour coded cores twisted together to form a pair, triple or quad, which is
individually screened with aluminium backed polyester tape with a tinned
copper drain wire. Each pair, triple or quad is wrapped with polyester tape to
Pair/Triple/Quad prevent electrical contact with adjacent pairs, triples or quads.
twisting / lay up Individually shielded pairs, triples or quads are laid up in concentric layers and
wrapped with a PETP tape.
Pairs, triples, or quads are identified by numbers printed directly on the
insulated conductors.
Inner covering F Flame retardant and halogen-free thermoplastic EP-rubber based compound
Tape over inner PET tape + rubberized Polyamide tape
covering
Armour/screen C Galvanized steel wire braid
Tape over armour/ PET tape + rubberised Polyamide tape
screen
U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound
Outer sheath
(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "BFCU(I)" "UKOOA code" "150/250V"
Marking text "number of pair, triples or quads" "conductor size" "BS7917" IEC60331-21
"IEC60332-3-22" (marking may differ on cable actually supplied)
Outer sheath colour Grey or Blue

Core identification
Pair - BlackWhite, numbered 1-1, 2-2, 3-3
Triple BlackWhiteRed, numbered 1-1-1, 2-2-2, 3-3-3
Quad BlackWhiteRedBlue, numbered 1-1-1-1, 2-2-2-2 ..

Each core is identified by contrasting numerals & words repeated


348
along the whole length of the cable.
Marine, Oil & Gas International
BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Range and dimensions


Approx
Thickness Thickness Approx Weight of Copper
Number No of Cross Conductor Insulation Diameter Diameter
Inner Outer Overall Cable content
of cores in section Diameter, Thickness Inner Braid
Sheath, Sheath, Diameter Approx. Approx.
elements element core, mm mm mm Sheath, Wire, mm
mm mm mm (Kg/Km) (kg/km)
mm
1 2 0.75 1.15 0.8 1 8 0.3 1.2 12 260 18
1 4 0.75 1.15 0.8 1.2 10 0.3 1.3 14 330 31
1 3 0.75 1.15 0.8 1 8.5 0.3 1.2 12.5 280 25
3 3 0.75 1.15 0.8 1.3 14.5 0.3 1.5 19 590 73
7 3 0.75 1.15 0.8 1.5 20 0.3 1.7 24.5 990 171
12 3 0.75 1.15 0.8 1.7 26.5 0.45 2 32.5 1640 293
1 2 0.75 1.15 0.8 1 8 0.3 1.2 12 245 18
1 4 0.75 1.15 0.8 1.2 10 0.3 1.3 14 330 31
1 3 0.75 1.15 0.8 1 8.5 0.3 1.2 12.5 280 25
3 3 0.75 1.15 0.8 1.3 14.5 0.3 1.5 19 590 73
7 3 0.75 1.15 0.8 1.5 20 0.3 1.7 24.5 990 171
12 3 0.75 1.15 0.8 1.7 26.5 0.45 2 32.5 1640 293
1 2 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 300 32
1 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 57
1 2 1.5 1.6 0.8 1.1 9.5 0.3 1.2 13 300 32
1 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 57
1 3 1.5 1.6 0.8 1.1 10 0.3 1.2 14 330 45
1 2 1 1.3 0.8 1 8.5 0.3 1.2 12.5 270 24
1 2 1 1.3 0.8 1 8.5 0.3 1.2 12.5 270 24
7 2 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 800 124
1 3 1 1.3 0.8 1.1 9 0.3 1.2 13 310 32
1 3 1.5 1.6 0.8 1.1 10 0.3 1.2 14 330 45
7 2 1.5 1.6 0.8 1.5 20.5 0.3 1.7 25 1030 222
7 2 1.5 1.6 0.8 1.5 20.5 0.3 1.7 25 1030 222
2 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18.5 500 64
1 4 1 1.3 0.8 1.2 10 0.3 1.4 14.5 360 41
1 4 1 1.3 0.8 1.2 10 0.3 1.4 14.5 360 41
1 3 1 1.3 0.8 1.1 9 0.3 1.2 13 310 32
7 2 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 800 124
20 2 0.75 1.15 0.8 1.9 30 0.45 2.1 36.5 2040 354
1 4 2.5 2 0.8 1.3 12 0.3 1.5 16.5 500 100
3 2 0.75 1.15 0.8 1.2 13.5 0.3 1.4 17.5 480 53
3 2 1 1.3 0.8 1.3 14 0.3 1.4 18.5 520 71
3 2 0.75 1.15 0.8 1.2 34913.5 0.3 1.4 17.5 480 53
Marine, Oil & Gas International
BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Approx
Thickness Thickness Approx Weight of Copper
Number No of Cross Conductor Insulation Diameter Diameter
Inner Outer Overall Cable content
of cores in section Diameter, Thickness Inner Braid
Sheath, Sheath, Diameter Approx. Approx.
elements element core, mm mm mm Sheath, Wire, mm
mm mm mm (Kg/Km) (kg/km)
mm
12 2 0.75 1.15 0.8 1.6 24 0.3 1.8 29 1240 213
20 2 0.75 1.15 0.8 1.9 30 0.45 2.1 36.5 2040 354
5 2 0.75 1.15 0.8 1.3 16 0.3 1.5 20.5 660 89
3 2 1.5 1.6 0.8 1.3 15 0.3 1.5 19.5 600 96
5 2 0.75 1.15 0.8 1.3 16 0.3 1.5 20.5 660 89
20 2 1.5 1.6 0.8 2 34 0.45 2.3 41 2640 636
1 4 1.5 1.6 0.8 1.2 11 0.3 1.4 15.5 410 57
5 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 840 159
5 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 840 159
12 2 0.75 1.15 0.8 1.6 24 0.3 1.8 29 1240 213
2 2 0.75 1.15 0.8 1.2 12.5 0.3 1.4 17 430 36
2 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18.5 500 64
2 2 0.75 1.15 0.8 1.2 12.5 0.3 1.4 17 430 36
2 3 0.75 1.15 0.8 1.3 14 0.3 1.4 18 490 49
2 3 1 1.3 0.8 1.3 14.5 0.3 1.5 19 530 65
2 3 1.5 1.6 0.8 1.3 15.5 0.3 1.5 20 600 89
3 3 1 1.3 0.8 1.3 15.5 0.3 1.5 20 630 97
3 3 1.5 1.6 0.8 1.4 16.5 0.3 1.5 21 730 134
3 2 1 1.3 0.8 1.3 14 0.3 1.4 18.5 520 71
3 2 1.5 1.6 0.8 1.3 15 0.3 1.5 19.5 600 96
12 2 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1750 382
12 2 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1750 382
20 2 1.5 1.6 0.8 2 34 0.45 2.3 41 2640 636

Electrical values
Insulation
Capacitance, Inductance, Resistance at 20 L/R ratio, (microH/ resistance
Type
approx. (nF/km) approx (mH/km) C, max. (Ohm/km) Ohm) (Minimum
MOhmx km)
Shielded pair 0,75 mm 90 0,75 26,7 14 940
Shielded triple 0,75 mm 90 0,75 26,7 14 940
Shielded quad 0,75 mm 60 0,91 26,7 14 940
Shielded pair 1 mm 100 0,73 20,0 18 840
Shielded triple 1 mm 100 0,73 20,0 18 840
Shielded quad 1 mm 70 0,95 20,0 18 840
Shielded pair 1,5 mm 110 0,68 13,7 24,8 730
Shielded triple 1,5 mm 110 0,68 13,7 24,8 730
Shielded quad 1,5 mm 80 0,99 13,7 24,8 730
Shielded pair 2,5 mm 120 0,70 350 7,56 46,3 620
Marine, Oil & Gas International
BFCU(I) 250V, Fire Resistant, Individual screened instrumentation
Ordering information
Part number Description Sheath Colour Design standard UKOOA Code
840009 BFCU(I) 250V 1PAIR 0.75mm GREY BS 7917 : 1999 GPF00
840010 BFCU(I) 250V 1QUAD 0.75mm GREY BS 7917 : 1999 GPX00
840017 BFCU(I) 250V 1TRIP 0.75mm GREY BS 7917 : 1999 GPR00
840018 BFCU(I) 250V 3TRIP 0.75mm GREY BS 7917 : 1999 GPS00
840019 BFCU(I) 250V 7TRIP 0.75mm GREY BS 7917 : 1999 GPT00
840020 BFCU(I) 250V 12TRIP 0.75mm GREY BS 7917 : 1999 GPU00
840029 BFCU(I) 250V 1PAIR 0.75mm BLUE BS 7917 : 1999 GMF00
840030 BFCU(I) 250V 1QUAD 0.75mm BLUE BS 7917 : 1999 GMX00
840037 BFCU(I) 250V 1TRIP 0.75mm BLUE BS 7917 : 1999 GMR00
840038 BFCU(I) 250V 3TRIP 0.75mm BLUE BS 7917 : 1999 GMS00
840039 BFCU(I) 250V 7TRIP 0.75mm BLUE BS 7917 : 1999 GMT00
840040 BFCU(I) 250V 12TRIP 0.75mm BLUE BS 7917 : 1999 GMU00
840041 BFCU(I) 250V 1PAIR 1.5mm GREY BS 6883 : 1991 GPF02
840042 BFCU(I) 250V 1QUAD 1.5mm GREY BS 6883 : 1991 GPX02
840045 BFCU(I) 250V 1PAIR 1.5mm BLUE BS 6883 : 1991 GMF02
840046 BFCU(I) 250V 1QUAD 1.5mm BLUE BS 6883 : 1991 GMX02
840087 BFCU(I) 250V 1TRIP 1.5mm BLUE BS 6883 : 1991 GMR02
840089 BFCU(I) 250V 1PAIR 1mm BLUE BS 7917 : 1999 GMF01
840123 BFCU(I) 250V 1PAIR 1mm GREY BS 7917 : 1999 GPF01
840125 BFCU(I) 250V 7PAIR 0.75mm GREY BS 7917 : 1999 GPJ00
840127 BFCU(I) 250V 1TRIP 1mm GREY BS 7917 : 1999 GPR01
840131 BFCU(I) 250V 1TRIP 1.5mm GREY BS 6883 : 1991 GPR02
840138 BFCU(I) 250V 7PAIR 1.5mm GREY BS 6883 : 1991 GPJ02
840139 BFCU(I) 250V 7PAIR 1.5mm BLUE BS 6883 : 1991 GMJ02
840140 BFCU(I) 250V 2PAIR 1.5mm BLUE BS 6883 : 1991 -
840141 BFCU(I) 250V 1QUAD 1mm GREY BS 7917 : 1999 GPX01
840142 BFCU(I) 250V 1QUAD 1mm BLUE BS 7917 : 1999 GMX01
840157 BFCU(I) 250V 1TRIP 1mm BLUE BS 7917 : 1999 GMR01
840175 BFCU(I) 250V 7PAIR 0.75mm BLUE BS 7917 : 1999 GMJ00
840200 BFCU(I) 250V 20PAIR 0.75mm GREY BS 7917 : 1999 GPL00
840202 BFCU(I) 250V 1QUAD 2.5mm GREY BS 6883 : 1991 GPX03
840217 BFCU(I) 250V 3PAIR 0.75mm BLUE BS 7917 : 1999 GMH00
840218 BFCU(I) 250V 3PAIR 1mm GREY BS 7917 : 1999 GPH01
840240 BFCU(I) 250V 3PAIR 0.75mm GREY BS 7917 : 1999 GPH00
840253 BFCU(I) 250V 12PAIR 0.75mm GREY BS 7917 : 1999 GPK00
840254 BFCU(I) 250V 20PAIR 0.75mm BLUE BS 7917 : 1999 GML00
840267 BFCU(I) 250V 5PAIR 0.75mm BLUE BS 6883 : 1991 -
840268 BFCU(I) 250V 3PAIR 1.5mm GREY BS 6883 : 1991 GPH02
840271 BFCU(I) 250V 5PAIR 0.75mm GREY BS 6883 : 1991 -
840280 BFCU(I) 250V 20PAIR 1.5mm GREY BS 6883 : 1991 GPL02
840281 BFCU(I) 250V 1QUAD 1.5mm GREY BS 6883 : 1991 GPX02
840290 BFCU(I) 250V 5PAIR 1.5mm GREY BS 6883 : 1991 -
840291 BFCU(I) 250V 5PAIR 1.5mm 351
BLUE BS 6883 : 1991 -
Marine, Oil & Gas International
BFCU(I) 250V, Fire Resistant, Individual screened instrumentation

Part number Description Sheath Colour Design standard UKOOA Code

840292 BFCU(I) 250V 12PAIR 0.75mm BLUE BS 7917 : 1999 GMK00

840314 BFCU(I) 250V 2PAIR 0.75mm GREY BS 6883 : 1991 -

840315 BFCU(I) 250V 2PAIR 1.5mm GREY BS 6883 : 1991 -

840316 BFCU(I) 250V 2PAIR 0.75mm BLUE BS 6883 : 1991 -

840322 BFCU(I) 250V 2TRIP 0.75mm GREY BS 6883 : 1991 -

840323 BFCU(I) 250V 2TRIP 1mm GREY BS 6883 : 1991 -

840324 BFCU(I) 250V 2TRIP 1.5mm GREY BS 6883 : 1991 -

840325 BFCU(I) 250V 3TRIP 1mm GREY BS 7917 : 1999 GPS01

840326 BFCU(I) 250V 3TRIP 1.5mm GREY BS 6883 : 1991 GPS02

840327 BFCU(I) 250V 3PAIR 1mm BLUE BS 7917 : 1999 GMH01

840328 BFCU(I) 250V 3PAIR 1.5mm BLUE BS 6883 : 1991 GMH02

840329 BFCU(I) 250V 12PAIR 1.5mm GREY BS 6883 : 1991 GPK02

840330 BFCU(I) 250V 12PAIR 1.5mm BLUE BS 6883 : 1991 GMK02

840331 BFCU(I) 250V 20PAIR 1.5mm BLUE BS 6883 : 1991 GML02

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation
Installation Installed Installation Temperature
10 x D 8xD 50 N /mm -20C

352
Marine, Oil & Gas International
RFCU 0.6/1KV Power, Control or Lighting cable
Flame retardant halogen-free power cable.
Enhanced oil-resistance.

RFCU 0.6/1kV

Operating temperature : 90C


Operating Voltage : 0,6/1kV

Application Standards applied


Armoured cable for fixed installation for power, BS6883 / UKOOA - Design
control or lighting in both EX and safe areas where BS6360 class 2 - Conductor
cable protection is required. General purpose use. BS7655 section 1.2 - Insulation
BS7655 section 2.6 - Sheath
Enhanced MUD resistant version also available for use
in areas exposed to mud and drilling / cleaning fluids, IEC 60332-1 - Flame Retardant
meeting the mud resistance requirement in NEK 606. IEC60332-3-22 - Flame retardant
IEC60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned stranded circular copper, BS 6360, class 2

Insulation R EP-rubber, GP4 to BS 7655: section 1.2

Lay up / Shielding Cores laid up in concentric layers

Inner covering F Flame retardant and halogen-free thermoset compound


Tape over inner PET tape + rubberized Polyamide tape
covering
Armour/screen C Galvanized steel wire braid
Tape over armour/ PET tape + rubberised Polyamide tape
screen
U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound
Outer sheath
(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "RFCU" "UKOOA code" "600/1000V" "number
Marking text of cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ
on cable actually supplied)

Outer sheath colour Black

Core identification
All cores are offwhite with black numbers No 1,2,3.

353
Marine, Oil & Gas International
RFCU 0.6/1KV Power, Control or Lighting cable

Range and dimensions

Approx
Thickness Thickness Approx Weight of Copper
Cross Conductor Insulation Diameter Diameter
Number of Inner Outer Overall Cable content
section Diameter, Thickness, inner Braid Wire,
cores Sheath, Sheath, Diameter, Approx. Approx.
core, mm mm mm Sheath, mm
mm mm mm (Kg/Km) (kg/km)
mm

2 1.5 1.6 0.8 1.1 8.5 0.3 1.2 12.5 280 28


2 2.5 2.0 0.8 1.1 9.5 0.3 1.2 13.5 320 46
2 4 2.55 1.0 1.2 11.5 0.3 1.3 15.5 440 74
3 1.5 1.6 0.8 1.1 9 0.3 1.2 13 310 42
3 2.5 2.0 0.8 1.1 10 0.3 1.3 14 360 69
3 4 2.55 1.0 1.2 12.5 0.3 1.3 16.5 490 110
3 6 3.15 1.0 1.2 13.5 0.3 1.4 18 610 164
3 16 5.15 1.0 1.4 18.5 0.3 1.6 23 1120 434
3 35 7.65 1.2 1.7 25.5 0.45 1.9 31 2150 927
3 70 10.85 1.4 2 34 0.45 2.2 40 3770 1863
4 1.5 1.6 0.8 1.1 10 0.3 1.3 14 350 56
4 4 2.55 1.0 1.2 13.5 0.3 1.4 18 590 147
4 6 3.15 1.0 1.3 15 0.3 1.5 19.5 740 218
4 16 5.15 1.0 1.5 20.5 0.3 1.7 25.5 1390 578
4 25 6.45 1.2 1.7 25 0.45 1.9 31 2130 917
4 35 7.65 1.2 1.8 28 0.45 2 34 2620 1236
7 2.5 2.0 0.8 1.2 13.5 0.3 1.4 18.5 590 161
12 2.5 2.0 0.8 1.4 18 0.3 1.6 22.5 900 275
19 2.5 2.0 0.8 1.5 21 0.3 1.7 27 1240 435
4 70 10.85 1.4 2.1 38 0.45 2.4 44 4670 2484
3 10 4.05 1.0 1.3 16 0.3 1.5 20.5 830 271
3 25 6.45 1.2 1.6 22.5 0.3 1.8 28 1640 688
4 10 4.05 1.0 1.4 17.5 0.3 1.6 22.5 1000 361
19 1.5 1.6 0.8 1.4 19 0.3 1.6 24 960 264
4 50 9.0 1.4 1.9 33 0.45 2.2 39.5 3480 1716
4 95 12.60 1.6 2.3 43.5 0.45 2.6 50.5 6080 3351
2 6 3.15 1.0 1.2 13 0.3 1.4 17 540 109
4 6 3.15 1.0 1.3 15 0.3 1.5 19.5 740 218
37 2.5 2.0 0.8 1.8 29 0.45 2 35 2270 847
2 16 5.15 1.0 1.4 17.5 0.3 1.5 22 940 289
27 2.5 2.0 0.8 1.7 25.5 0.45 1.9 31.5 1820 618
7 1.5 1.6 0.8 1.2 12 0.3 1.3 17 470 98
12 1.5 1.6 0.8 1.3 16 0.3 1.5 20.5 710 167
2 35 7.65 1.2 1.6 23.5 0.3 1.8 28.5 1650 618
3 50 9.0 1.4 1.8 29.5 0.45 2 35 2830 1287
4 2.5 2.0 0.8 1.1 11 0.3 1.3 15 420 92
3 95 12.60 1.6 2.2 39 0.45 2.4 45 4860 2513
5 1.5 1.6 0.8 1.1 11 0.3 1.3 15 440 83

354
Marine, Oil & Gas International
RFCU 0.6/1KV Power, Control or Lighting cable
Ordering information
Part number Description Sheath Colour Design standard UKOOA Code

840049 RFCU 0.6/1kV 2X 1.5mm BLACK BS 6883 : 1999 WB202


840050 RFCU 0.6/1kV 2X 2.5mm BLACK BS 6883 : 1999 WB203
840051 RFCU 0.6/1kV 2X 4mm BLACK BS 6883 : 1999 WB204
840052 RFCU 0.6/1kV 3X 1.5mm BLACK BS 6883 : 1999 WB302
840053 RFCU 0.6/1kV 3X 2.5mm BLACK BS 6883 : 1999 WB303
840054 RFCU 0.6/1kV 3X 4mm BLACK BS 6883 : 1999 WB304
840055 RFCU 0.6/1kV 3X 6mm BLACK BS 6883 : 1999 WB306
840056 RFCU 0.6/1kV 3X 16mm BLACK BS 6883 : 1999 WB316
840057 RFCU 0.6/1kV 3X 35mm BLACK BS 6883 : 1999 WB335
840058 RFCU 0.6/1kV 3X 70mm BLACK BS 6883 : 1999 WB370
840059 RFCU 0.6/1kV 4X 1.5mm BLACK BS 6883 : 1999 WB402
840061 RFCU 0.6/1kV 4X 4mm BLACK BS 6883 : 1999 WB404
840062 RFCU 0.6/1kV 4X 6mm BLACK BS 6883 : 1999 WB406
840063 RFCU 0.6/1kV 4X 16mm BLACK BS 6883 : 1999 WB416
840064 RFCU 0.6/1kV 4X 25mm BLACK BS 6883 : 1999 WB425
840065 RFCU 0.6/1kV 4X 35mm BLACK BS 6883 : 1999 WB435
840068 RFCU 0.6/1kV 7X 2.5mm BLACK BS 6883 : 1999 WB703
840070 RFCU 0.6/1kV 12X 2.5mm BLACK BS 6883 : 1999 WBA03
840071 RFCU 0.6/1kV 19X 2.5mm BLACK BS 6883 : 1999 WBB03
840088 RFCU 0.6/1kV 4X 70mm BLACK BS 6883 : 1999 WB470
840154 RFCU 0.6/1kV 3X 10mm BLACK BS 6883 : 1999 WB310
840158 RFCU 0.6/1kV 3X 25mm BLACK BS 6883 : 1999 WB325
840159 RFCU 0.6/1kV 4X 10mm BLACK BS 6883 : 1999 WB410
840160 RFCU 0.6/1kV 19X 1.5mm BLACK BS 6883 : 1999 WBB02
840166 RFCU 0.6/1kV 4X 50mm BLACK BS 6883 : 1999 WB450
840242 RFCU 0.6/1kV 4X 95mm BLACK BS 6883 : 1999 WB495
840245 RFCU 0.6/1kV 2X 6mm BLACK BS 6883 : 1999 WB206
840246 RFCU 0.6/1kV 4X 6mm BLACK BS 6883 : 1999 WB406
840256 RFCU 0.6/1kV 37X 2.5mm BLACK BS 6883 : 1991 WBD03
840258 RFCU 0.6/1kV 2X 16mm BLACK BS 6883 : 1999 WB216
840262 RFCU 0.6/1kV 27X 2.5mm BLACK BS 6883 : 1991 WBC03
840263 RFCU 0.6/1kV 7X 1.5mm BLACK BS 6883 : 1999 WB702
840264 RFCU 0.6/1kV 12X 1.5mm BLACK BS 6883 : 1999 WBA02
840269 RFCU 0.6/1kV 2X 35mm BLACK BS 6883 : 1999 WB235
840283 RFCU 0.6/1kV 3X 50mm BLACK BS 6883 : 1999 WB350
840284 RFCU 0.6/1kV 4X 2.5mm BLACK BS 6883 : 1999 WB403
840311 RFCU 0.6/1kV 3X 95mm BLACK BS 6883 : 1999 WB395
840338 RFCU 0.6/1kV 5X 1.5mm 355
BLACK BS 6883 : 1999 -
Marine, Oil & Gas International
RFCU 0.6/1KV Power, Control or Lighting cable
Electrical values
Number of Cross section Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
cores core, mm resistance at resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352 rating 1
20C, Ohm/km 90C, Ohm/km Table B.4, second,
Ampere Ampere
2 1.5 12.2 15.6 0.103 0.123 20 210
2 2.5 7.56 9.64 0.096 0.115 26 350
2 4 4.7 5.99 0.096 0.115 34 560
3 1.5 12.2 15.6 0.103 0.123 16 210
3 2.5 7.56 9.64 0.096 0.115 21 350
3 4 4.7 5.99 0.096 0.115 28 560
3 6 3.11 3.97 0.090 0.108 36 840
3 16 1.16 1.48 0.080 0.096 67 2240
3 35 0.529 0.675 0.076 0.092 110 4900
3 70 0.27 0.344 0.074 0.088 169 9800
4 1.5 12.2 15.6 0.103 0.123 16 210
4 4 4.7 5.99 0.096 0.115 28 560
4 6 3.11 3.97 0.090 0.108 36 840
4 16 1.16 1.48 0.080 0.096 67 2240
4 25 0.734 0.936 0.079 0.095 89 3500
4 35 0.529 0.675 0.076 0.092 110 4900
7 2.5 7.56 9.64 0.096 0.115 15.5 350
12 2.5 7.56 9.64 0.096 0.115 13 350
19 2.5 7.56 9.64 0.096 0.115 11 350
4 70 0.27 0.344 0.074 0.088 169 9800
3 10 1.84 2.35 0.084 0.101 50 1400
3 25 0.734 0.936 0.079 0.095 89 3500
4 10 1.84 2.35 0.084 0.101 50 1400
19 1.5 12.2 15.6 0.103 0.123 8.5 210
4 50 0.391 0.499 0.076 0.092 137 7000
4 95 0.195 0.249 0.073 0.088 205 13300
2 6 3.11 3.97 0.090 0.108 44 840
4 6 3.11 3.97 0.090 0.108 36 840
37 2.5 7.56 9.64 0.096 0.115 9 350
2 16 1.16 1.48 0.080 0.096 80 2240
27 2.5 7.56 9.64 0.096 0.115 10 350
7 1.5 12.2 15.6 0.103 0.123 12 210
12 1.5 12.2 15.6 0.103 0.123 10 210
2 35 0.529 0.675 0.076 0.092 133 4900
3 50 0.391 0.499 0.076 0.092 137 7000
4 2.5 7.56 9.64 0.096 0.115 21 350
3 95 0.195 0.249 0.073 0.088 205 13300
5 1.5 12.2 15.6 0.103 0.123 13.5 210

Ambient temperature correction factors


Ambient
35 40 45 50 55 60 65 70 75 80
Temp C
Rating
1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47
factor

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation
Installation Installed Installation Temperature
OD < 25 mm - 4 x D, OD > 25
8xD 50 N /mm -20C
mm - 6 x D

356
Marine, Oil & Gas International
RFCU(C) 250V, Collective screened instrumentation
Flame retardant halogen-free instrumentation
cable. Enhanced oil-resistance.

RFCU(C) 250V

Operating temperature : 90C


Operating Voltage : 250V

Application Standards applied


Fixed installation for instrumentation, communication, BS6883 / UKOOA - Design
control and alarm systems in both EX and safe areas. BS6360 class 2 or 5 - Conductor
BS7655 section 1.2 - Insulation
Enhanced MUD resistant version also available for use
BS7655 section 2.6 - Sheath
in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606. IEC 60332-1 - Flame Retardant
IEC60332-3-22 - Flame retardant
IEC60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
Conductor
Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)
Insulation R EP-rubber, GP4 to BS 7655: section 1.2
Colour coded cores twisted together to form a pair, triple or quad, wrapped
with polyester tape. Pairs, triples or quads are laid up, collectively screened
Pair/Triple/Quad
with aluminium backed polyester tape with tinned copper drain wire. Pairs,
twisting
triples, or quads are identified by numbers printed directly on the insulated
conductors.
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner PET tape + rubberized Polyamide tape
covering
Armour/screen C Galvanized steel wire braid
Tape over armour/ PET tape + rubberised Polyamide tape
screen
U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound
Outer sheath
(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "RFCU(C)" "UKOOA code" "150/250V"
Marking text "number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-3-
22" (marking may differ on cable actually supplied)

Outer sheath colour Grey or Blue

Core identification
Pair - BlackWhite, numbered 1-1, 2-2, 3-3
Triple BlackWhiteRed, numbered 1-1-1, 2-2-2, 3-3-3
Quad BlackWhiteRedBlue, numbered 1-1-1-1, 2-2-2-2 ..

Each core is identified by contrasting numerals & words repeated


357
along the whole length of the cable.
Marine, Oil & Gas International
RFCU(C) 250V, Collective screened instrumentation

Range and dimensions


Thickness Diameter Thickness Approx Weight of Copper
Number No of Cross Conductor Insulation Diameter
Inner Inner Outer Overall Cable content
of cores in section Diameter, Thickness Braid
Sheath, Sheath, Sheath, Diameter , Approx. Approx.
elements element core, mm mm mm Wire, mm
mm mm mm mm (Kg/Km) (kg/km)
3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 420 45
7 2 0.75 1.15 0.8 1.4 16.5 0.3 1.5 21 660 97
12 2 0.75 1.15 0.8 1.6 21.5 0.3 1.7 26 1000 164
27 2 0.75 1.15 0.8 1.9 29 0.45 2.2 35.5 1980 359
3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 420 45
7 2 0.75 1.15 0.8 1.4 16.5 0.3 1.5 21 660 97
12 2 0.75 1.15 0.8 1.6 21.5 0.3 1.7 26 1000 164
19 2 0.75 1.15 0.8 1.7 24.5 0.45 1.9 30 1460 257
27 2 0.75 1.15 0.8 1.9 29 0.45 2.2 35.5 1980 359
2 2 1 1.3 0.8 1.2 12 0.3 1.4 16.5 400 41
20 2 0.75 1.15 0.8 1.8 25.5 0.45 2 31.5 1570 271
20 2 0.75 1.15 0.8 1.8 25.5 0.45 2 31.5 1570 271
7 2 1.5 1.6 0.8 1.4 18.5 0.3 1.6 23 850 183
12 2 1.5 1.6 0.8 1.7 24.5 0.45 1.9 30 1470 309
20 2 1.5 1.6 0.8 1.9 29 0.45 2.2 35.5 2130 511
27 2 1.5 1.6 0.8 2.1 33.5 0.45 2.4 40 2650 687
7 3 0.75 1.15 0.8 1.4 18 0.3 1.6 22.5 820 144
12 3 0.75 1.15 0.8 1.7 24 0.3 1.9 29 1290 244
3 3 0.75 1.15 0.8 1.3 13.5 0.3 1.4 18 510 65
3 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 82
3 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 82
3 2 1 1.3 0.8 1.2 12.5 0.3 1.4 17 460 58
3 3 0.75 1.15 0.8 1.3 13.5 0.3 1.4 18 510 65
12 3 1.5 1.6 0.8 1.8 27.5 0.45 2 33.5 1840 461
3 2 1.5 1.6 0.8 1.3 14 0.3 1.4 18 520 82
5 2 1.5 1.6 0.8 1.4 17 0.3 1.6 21.5 730 132
2 2 0.75 1.15 0.8 1.2 11.5 0.3 1.3 15.5 370 31
2 2 1.5 1.6 0.8 1.2 13 0.3 1.4 17 450 57
5 2 0.75 1.15 0.8 1.3 15 0.3 1.5 19.5 570 71

358
Marine, Oil & Gas International
RFCU(C) 250V, Collective screened instrumentation
Electrical values
Insulation
Inductance, Resistance at
Capacitance, L/R ratio, resistance
Type approx, (mH/ 20C, max.
approx. (nF/km) (microH/Ohm) (Minimum
km) (Ohm/km)
Mohm x km)
Unshielded pair 0,75 mm 80 0,75 26,7 14 940
Unshielded triple 0,75 mm 80 0,75 26,7 14 940
Unshielded pair 1,0 mm 85 0,73 20,0 18 840
Unshielded triple 1,0 mm 85 0,73 20,0 18 840
Unshielded pair 1,5 mm 90 0,68 13,7 24,8 730
Unshielded triple 1,5 mm 90 0,68 13,7 24,8 730
Unshielded pair 2,5 mm 90 0,70 7,56 46,3 620
Unshielded triple 2,5 mm 90 0,70 7,56 46,3 620

Ordering information
Part number Description Sheath Colour Design standard UKOOA Code
840003 RFCU(C) 250V 3PAIR 0.75mm GREY BS 6883 : 1999 KJH00
840004 RFCU(C) 250V 7PAIR 0.75mm GREY BS 6883 : 1999 KJJ00
840005 RFCU(C) 250V 12PAIR 0.75mm GREY BS 6883 : 1999 KJK00
840007 RFCU(C) 250V 27PAIR 0.75mm GREY BS 6883 : 1999 KJM00
840023 RFCU(C) 250V 3PAIR 0.75mm BLUE BS 6883 : 1999 KGH00
840024 RFCU(C) 250V 7PAIR 0.75mm BLUE BS 6883 : 1999 KGJ00
840025 RFCU(C) 250V 12PAIR 0.75mm BLUE BS 6883 : 1999 KGK00
840026 RFCU(C) 250V 19PAIR 0.75mm BLUE BS 6883 : 1991 -
840027 RFCU(C) 250V 27PAIR 0.75mm BLUE BS 6883 : 1999 KGM00
840117 RFCU(C) 250V 2PAIR 1mm GREY BS 6883 : 1991 -
840128 RFCU(C) 250V 20PAIR 0.75mm GREY BS 6883 : 1999 KJL00
840156 RFCU(C) 250V 20PAIR 0.75mm BLUE BS 6883 : 1999 KGL00
840176 RFCU(C) 250V 7PAIR 1.5mm GREY BS 6883 : 1991 KJJ02
840177 RFCU(C) 250V 12PAIR 1.5mm GREY BS 6883 : 1991 KJK02
840178 RFCU(C) 250V 20PAIR 1.5mm GREY BS 6883 : 1991 KJL02
840179 RFCU(C) 250V 27PAIR 1.5mm GREY BS 6883 : 1991 KJM02
840222 RFCU(C) 250V 7TRIP 0.75mm BLUE BS 6883 : 1999 KGT00
840223 RFCU(C) 250V 12TRIP 0.75mm BLUE BS 6883 : 1999 KGU00
840231 RFCU(C) 250V 3TRIP 0.75mm GREY BS 6883 : 1999 KJS00
840236 RFCU(C) 250V 3PAIR 1.5mm BLUE BS 6883 : 1991 KGH02
840237 RFCU(C) 250V 3PAIR 1.5mm GREY BS 6883 : 1991 KJH02
840241 RFCU(C) 250V 3PAIR 1mm GREY BS 6883 : 1999 KJH01
840274 RFCU(C) 250V 3TRIP 0.75mm GREY BS 6883 : 1999 KJS00
840277 RFCU(C) 250V 12TRIP 1.5mm BLUE BS 6883 : 1991 KGU02
840294 RFCU(C) 250V 3PAIR 1.5mm GREY BS 6883 : 1991 KJH02
840295 RFCU(C) 250V 5PAIR 1.5mm GREY BS 6883 : 1991 -
840332 RFCU(C) 250V 2PAIR 0.75mm GREY BS 6883 : 1991 -
840333 RFCU(C) 250V 2PAIR 1.5mm GREY BS 6883 : 1991 -
840334 RFCU(C) 250V 5PAIR 0.75mm GREY BS 6883 : 1991 -

359
Marine, Oil & Gas International
RFCU(C) 250V, Collective screened instrumentation

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation
Installation Installed Installation Temperature

10 x D 8xD 50 N /mm -20C

360
Marine, Oil & Gas International
RFCU(I) 250V, Individual screened instrumentation
Flame retardant halogen-free instrumentation
cable. Enhanced oil-resistance.

RFCU(I) 250V

Operating temperature : 90C


Operating Voltage : 250V

Application Standards applied


Fixed installation for instrumentation, communication, BS6883 / UKOOA - Design
control and alarm systems in both EX and safe areas. BS6360 class 2 or 5 - Conductor
BS7655 section 1.2 - Insulation
Enhanced MUD resistant version also available for use
BS7655 section 2.6 - Sheath
in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606. IEC 60332-1 - Flame Retardant
IEC60332-3-22 - Flame retardant
IEC60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke
Construction
Code
Letter
Tinned flexible circular copper, 0.75, 1.0 & 1.5 sqmm (BS6360 class 5)
Conductor
Tinned stranded circular copper, 2.5sqmm (BS 6360, class 2)
Insulation R EP-rubber, GP4 to BS 7655: section 1.2
Colour coded cores twisted together to form a pair, triple or quad, which is
individually screened with aluminium backed polyester tape with a tinned
copper drain wire. Each pair, triple or quad is wrapped with polyester tape to
Pair/Triple/Quad prevent electrical contact with adjacent pairs, triples or quads.
twisting / lay up Individually shielded pairs, triples or quads are laid up in concentric layers and
wrapped with a PETP tape.
Pairs, triples, or quads are identified by numbers printed directly on the
insulated conductors.
Inner covering F Flame retardant and halogen-free thermoset compound
Tape over inner PET tape + rubberized Polyamide tape
covering
Armour/screen C Galvanized steel wire braid
Tape over armour/ PET tape + rubberised Polyamide tape
screen
U Flame retardant, halogen-free, enhanced oil-resisting thermoset compound
Outer sheath
(LSF), SW4 to BS 7655 section 2.6
"metre mark" "year" "DRAKA" "RFCU(I)" "UKOOA code" "150/250V"
Marking text "number of pair, triples or quads" "conductor size" "BS6883" "IEC60332-3-
22" (marking may differ on cable actually supplied)

Outer sheath colour Grey or Blue


Core identification
Pair - BlackWhite, numbered 1-1, 2-2, 3-3
Triple BlackWhiteRed, numbered 1-1-1, 2-2-2, 3-3-3
Quad BlackWhiteRedBlue, numbered 1-1-1-1, 2-2-2-2 ..

Each core is identified by contrasting numerals & words repeated


361
along the whole length of the cable.
Marine, Oil & Gas International
RFCU(I) 250V, Individual screened instrumentation

Range and dimensions


Approx
Thickness Thickness Approx Weight of Copper
Number No of Cross Conductor Insulation Diameter Diameter
Inner Outer Overall Cable content
of cores in section Diameter, Thickness Inner Braid
Sheath, Sheath, Diameter Approx. Approx.
elements element core, mm mm mm Sheath, Wire, mm
mm mm mm (Kg/Km) (kg/km)
mm
1 2 0.75 1.15 0.8 1 7.5 0.3 1.2 11.5 230 18
1 4 0.75 1.15 0.8 1.2 9 0.3 1.3 13.5 310 31
1 2 0.75 1.15 0.8 1 7.5 0.3 1.2 11.5 230 18
1 4 0.75 1.15 0.8 1.2 9 0.3 1.3 13.5 310 31
1 2 1 1.3 0.8 1 8 0.3 1.2 12 240 24
1 2 1 1.3 0.8 1 8 0.3 1.2 12 240 24
1 4 1 1.3 0.8 1.2 9.5 0.3 1.4 14 340 41
3 2 1 1.3 0.8 1.3 13 0.3 1.4 17 490 71
1 3 1 1.3 0.8 1.1 8.5 0.3 1.2 12.5 285 32
7 3 0.75 1.15 0.8 1.5 18.5 0.3 1.7 23.5 900 170
12 3 0.75 1.15 0.8 1.7 25 0.45 2 31 1530 293
7 2 0.75 1.15 0.8 1.4 16.5 0.3 1.6 21 720 124
7 2 0.75 1.15 0.8 1.4 16.5 0.3 1.6 21 720 124
12 2 0.75 1.15 0.8 1.6 22 0.3 1.8 27 1110 212
12 2 0.75 1.15 0.8 1.6 22 0.3 1.8 27 1110 212
3 3 0.75 1.15 0.8 1.3 14 0.3 1.5 18.5 530 73
3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 430 53
3 2 0.75 1.15 0.8 1.2 12 0.3 1.4 16.5 430 53
20 2 1.5 1.6 0.8 2 31.5 0.45 2.3 38 2430 635
19 2 0.75 1.15 0.8 1.8 26 0.45 2 32 1660 336
12 3 0.75 1.15 0.8 1.7 25 0.45 2 31 1530 293
7 3 0.75 1.15 0.8 1.5 18.5 0.3 1.7 23.5 900 170
3 2 1.5 1.6 0.8 1.3 14 0.3 1.5 18.5 560 95
3 3 0.75 1.15 0.8 1.3 14 0.3 1.5 18.5 530 73
3 2 1.5 1.6 0.8 1.3 14 0.3 1.5 18.5 560 95
1 2 1.5 1.6 0.8 1.1 8.5 0.3 1.2 12.5 290 32
1 3 1.5 1.6 0.8 1.1 9 0.3 1.2 13 320 45
1 3 0.75 1.15 0.8 1 8 0.3 1.2 12 245 25
1 4 1 1.3 0.8 1.2 9.5 0.3 1.4 14 340 41
1 4 1.5 1.6 0.8 1.2 10 0.3 1.4 14.5 370 57
1 3 1.5 1.6 0.8 1.1 9 0.3 1.2 13 320 45

362
Marine, Oil & Gas International
RFCU(I) 250V, Individual screened instrumentation
Electrical values
Insulation
Inductance,
Capacitance, Resistance at 20C, L/R ratio, (microH/ resistance
Type approx (mH/
approx. (nF/km) max. (Ohm/km) Ohm) (Minimum MOhmx
km)
km)
Shielded pair 0,75 mm 90 0,75 26,7 14 940
Shielded triple 0,75 mm 90 0,75 26,7 14 940
Shielded quad 0,75 mm 60 0,91 26,7 14 940
Shielded pair 1 mm 100 0,73 20,0 18 840
Shielded triple 1 mm 100 0,73 20,0 18 840
Shielded quad 1 mm 70 0,95 20,0 18 840
Shielded pair 1,5 mm 110 0,68 13,7 24,8 730
Shielded triple 1,5 mm 110 0,68 13,7 24,8 730
Shielded quad 1,5 mm 80 0,99 13,7 24,8 730
Shielded pair 2,5 mm 120 0,70 7,56 46,3 620

Ordering information
Part number Description Sheath Colour Design standard UKOOA Code
840001 RFCU(I) 250V 1PAIR 0.75mm GREY BS 6883 : 1999 KKF00
840002 RFCU(I) 250V 1QUAD 0.75mm GREY BS 6883 : 1999 KKX00
840021 RFCU(I) 250V 1PAIR 0.75mm BLUE BS 6883 : 1999 KHF00
840022 RFCU(I) 250V 1QUAD 0.75mm BLUE BS 6883 : 1999 KHX00
840094 RFCU(I) 250V 1PAIR 1mm GREY BS 6883 : 1999 KKF01
840095 RFCU(I) 250V 1PAIR 1mm BLUE BS 6883 : 1999 KHF01
840096 RFCU(I) 250V 1QUAD 1mm BLUE BS 6883 : 1999 KHX01
840100 RFCU(I) 250V 3PAIR 1mm BLUE BS 6883 : 1999 KHH01
840121 RFCU(I) 250V 1TRIP 1mm GREY BS 6883 : 1999 KKR01
840211 RFCU(I) 250V 7TRIP 0.75mm BLUE BS 6883 : 1999 KHT00
840212 RFCU(I) 250V 12TRIP 0.75mm BLUE BS 6883 : 1999 KHU00
840214 RFCU(I) 250V 7PAIR 0.75mm GREY BS 6883 : 1999 KKJ00
840215 RFCU(I) 250V 7PAIR 0.75mm BLUE BS 6883 : 1999 KHJ00
840216 RFCU(I) 250V 12PAIR 0.75mm GREY BS 6883 : 1999 KKK00
840221 RFCU(I) 250V 12PAIR 0.75mm BLUE BS 6883 : 1999 KHK00
840224 RFCU(I) 250V 3TRIP 0.75mm BLUE BS 6883 : 1999 KHS00
840226 RFCU(I) 250V 3PAIR 0.75mm GREY BS 6883 : 1999 KKH00
840227 RFCU(I) 250V 3PAIR 0.75mm BLUE BS 6883 : 1999 KHH00
840235 RFCU(I) 250V 20PAIR 1.5mm GREY BS 6883 : 1991 KKL02
840238 RFCU(I) 250V 19PAIR 0.75mm BLUE BS 6883 : 1991 -
840239 RFCU(I) 250V 12TRIP 0.75mm GREY BS 6883 : 1999 KKU00
840272 RFCU(I) 250V 7TRIP 0.75mm GREY BS 6883 : 1999 KKT00
840275 RFCU(I) 250V 3PAIR 1.5mm GREY BS 6883 : 1991 KKH02
840276 RFCU(I) 250V 3TRIP 0.75mm GREY BS 6883 : 1999 KKS00
840278 RFCU(I) 250V 3PAIR 1.5mm BLUE BS 6883 : 1991 KHH02
840293 RFCU(I) 250V 1PAIR 1.5mm GREY BS 6883 : 1991 KKF02
840296 RFCU(I) 250V 1TRIP 1.5mm GREY BS 6883 : 1991 KKR02
840335 RFCU(I) 250V 1TRIP 0.75mm GREY BS 6883 : 1999 KKR00
840336 RFCU(I) 250V 1QUAD 1mm GREY BS 6883 : 1999 KKX01
840337 RFCU(I) 250V 1QUAD 1.5mm GREY BS 6883 : 1991 KKX02
840339 RFCU(I) 250V 1TRIP 1.5mm BLUE BS 6883 : 1991 KHR02
363
Marine, Oil & Gas International
RFCU(I) 250V, Individual screened instrumentation

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation
Installation Installed Installation Temperature
10 x D 8xD 50 N /mm -20C

364
Marine, Oil & Gas International
RU 0.6/1KV Unarmoured power cable
Flame retardant halogen-free power cable.
Enhanced oil-resistance.

RU 0.6/1kV

Operating temperature : 90C


Operating Voltage : 0.6/1kV

Application Standards applied


Unarmoured cable for fixed installation where cable BS6883 - Design
protection is not required. Power, control and lighting BS6360 class 2 - Conductor
in safe areas. BS7655 section 1.2 - Insulation
BS7655 section 2.6 - Sheath
Enhanced MUD resistant version also available for use
in areas exposed to mud and drilling / cleaning fluids, IEC 60332-1 - Flame Retardant
meeting the mud resistance requirement in NEK 606. IEC60332-3-22 - Flame retardant
IEC60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned stranded circular copper, BS6360, class 2
Insulation R EP-rubber, GP4 to BS7655:section 1.2
Inner sheath No inner sheath, additional tapes may be applied
Armour/screen No armour
Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF)
Outer sheath U
SW4 to BS7655 section 2.6. (Mud resistant version available on request)
"metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of
Marking text cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable
actually supplied)
Outer sheath
Black
colour

Core identification
All cores are offwhite with black numbers No 1,2,3.

365
Marine, Oil & Gas International
RU 0.6/1KV Unarmoured power cable
Range and dimensions
Weight of Copper content
Number of Cross section Conductor Insulation Thickness Outer Approx Overall
Cable Approx. Approx.
cores core, mm Diameter, mm Thickness, mm Sheath, mm Diameter, mm
(Kg/Km) (Kg/Km)
2 1.5 1.6 0.8 1.1 8.5 120 28
2 2.5 2.0 0.8 1.1 9.5 150 46
3 1.5 1.6 0.8 1.1 9 140 42
3 2.5 2.0 0.8 1.1 10 180 69
3 4 2.55 1.0 1.2 12 275 110
3 6 3.15 1.0 1.2 13.5 360 164
4 1.5 1.6 0.8 1.1 10 165 56
4 2.5 2.0 0.8 1.1 11 220 92
3 10 4.05 1.0 1.3 15.5 530 271
3 16 5.15 1.0 1.4 18 770 434

Ordering information
Part number Description Sheath Colour Design standard
840300 RU 0.6/1kV 2X 1.5mm BLACK BS 6883:1999
840301 RU 0.6/1kV 2X 2.5mm BLACK BS 6883:1999
840302 RU 0.6/1kV 3X 1.5mm BLACK BS 6883:1999
840303 RU 0.6/1kV 3X 2.5mm BLACK BS 6883:1999
840304 RU 0.6/1kV 3X 4mm BLACK BS 6883:1999
840305 RU 0.6/1kV 3X 6mm BLACK BS 6883:1999
840306 RU 0.6/1kV 4X 1.5mm BLACK BS 6883:1999
840307 RU 0.6/1kV 4X 2.5mm BLACK BS 6883:1999
840312 RU 0.6/1kV 3X 10mm BLACK BS 6883:1999
840313 RU 0.6/1kV 3X 16mm BLACK BS 6883:1999

Electrical values
Number of Cross section Max. conductor Max. conductor Reactance at Reactance at Current rating Short circuit
cores core, mm resistance at resistance at 50Hz, Ohm/km 60Hz, Ohm/km IEC 60092-352 rating 1
20C, Ohm/km 90C, Ohm/km Table B.4, second,
Ampere Ampere
2 1.5 12.2 15.6 0.103 0.123 20 210
2 2.5 7.56 9.64 0.096 0.115 26 350
3 1.5 12.2 15.6 0.103 0.123 16 210
3 2.5 7.56 9.64 0.096 0.115 21 350
3 4 4.7 5.90 0.096 0.115 28 560
3 6 3.11 3.97 0.090 0.108 36 840
4 1.5 12.2 15.6 0.103 0.123 16 210
4 2.5 7.56 9.64 0.096 0.115 21 350
3 10 1.84 2.35 0.084 0.101 50 1400
3 16 1.16 1.48 0.080 0.096 67 2240
Ambient temperature correction factors
Ambient
35 40 45 50 55 60 65 70 75 80
Temp C
Rating
1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47
factor

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation
Installation Installed Installation Temperature
OD < 25 mm - 4 x D, OD > 25
8xD
mm - 6 x D 366 50 N /mm -20C
Marine, Oil & Gas International
RU 0.6/1KV Earthing cable
Flame retardant halogen-free earthing cable.
Enhanced oil-resistance.

RU 0.6/1kV

Operating temperature : 90C


Operating Voltage : 0.6/1kV

Application Standards applied


Unarmoured cable for fixed installation for earthing BS6883 - Design
purposes in safe areas. BS6360 class 2 - Conductor
BS7655 section 1.2 - Insulation
Enhanced MUD resistant version also available for use
BS7655 section 2.6 - Sheath
in areas exposed to mud and drilling / cleaning fluids,
meeting the mud resistance requirement in NEK 606. IEC 60332-1 - Flame Retardant
IEC60332-3-22 - Flame retardant
IEC60754-1,2 - Halogen Free
IEC 61034-1,2 - Low Smoke

Construction
Code
Letter
Conductor Tinned stranded circular copper, BS6360, class 2
Insulation R EP-rubber, GP4 to BS7655:section 1.2
Inner sheath No inner sheath, additional tapes may be applied
Armour/screen No armour
Flame retardant, halogen-free, enhanced oil resisting thermoset compound (LSF)
Outer sheath U
SW4 to BS7655 section 2.6. (Mud resistant version available on request)
"metre mark" "year" "DRAKA" "RU" "UKOOA code" "600/1000V" "number of
Marking text cores" "conductor size" "BS6883" "IEC60332-3-22" (marking may differ on cable
actually supplied)
Outer sheath
Green/Yellow
colour

Core identification
Single core - off white

367
Marine, Oil & Gas International
RU 0.6/1KV Earthing cable

Range and dimensions


Thickness Approx Weight Copper content
Number of Cross section Conductor Insulation Approx Overall
Outer Sheath, of Cable Approx.
cores core, mm Diameter, mm Thickness, mm Diameter, mm
mm (Kg/Km) (Kg/Km)
1 6 3.15 1.0 1 7.5 115 55
1 16 5.15 1.0 1.1 9.5 230 144
1 25 6.45 1.2 1.2 11.5 340 229
1 35 7.65 1.2 1.2 12.5 440 308
1 70 10.85 1.4 1.3 16.5 820 620

Ordering information
Part number Description Sheath Colour Design standard

840080 RU 0.6/1kV 1X 6mm YELLOW/GREEN BS 6883:1999

840081 RU 0.6/1kV 1X 16mm YELLOW/GREEN BS 6883:1999


840082 RU 0.6/1kV 1X 25mm YELLOW/GREEN BS 6883:1999
840083 RU 0.6/1kV 1X 35mm YELLOW/GREEN BS 6883:1999
840084 RU 0.6/1kV 1X 70mm YELLOW/GREEN BS 6883:1999

Electrical values
Number of cores Cross section core, Max. conductor Max. conductor Current rating IEC Short circuit rating 1
mm resistance at 20C, resistance at 90C, 60092-352 Table second, Ampere
Ohm/km Ohm/km B.4, Ampere
1 6 3.11 3.97 52 840
1 16 1.16 1.48 96 2240

1 25 0.734 0.936 127 3500

1 35 0.529 0.675 157 4900


1 70 0.27 0.344 242 9800

Ambient temperature correction factors


Ambient
35 40 45 50 55 60 65 70 75 80
Temp C
Rating
1.11 1.05 1.00 0.94 0.88 0.82 0.75 0.67 0.50 0.47
factor

Installation recommendations
Minimum Bending Radius during Minimum Bending Radius Fixed Maximum Tensile Load During Minimum Installation
Installation Installed Installation Temperature
OD < 25 mm - 4 x D, OD > 25
8xD 50 N /mm -20C
mm - 6 x D

368
For maintenance and repair needs, or expert guidance for new-build
projects, please contact any of our worldwide locations:

EUROPE: AMERICAS: ASIA-PACIFIC:


Unit 3 Peterseat Drive 1610 Greens Road, Suite 25 Tuas South Street 1
Peterseat Park 300 Singapore 638034
Altens Industrial Estate Houston, TX 77032 tel: +65 6897 7888
Aberdeen AB12 3HT U.S.A. fax: +65 6897 7333
U.K. tel: +1 281 209 1070
tel: +44 1224 244800 fax: +1 281 209 3857
fax: +44 1224 249839

www.DrakaMOG.com

2009 Draka Offshore. All rights reserved.

Вам также может понравиться