60 Hz Inductor Design
60 Hz Inductor Design
Requirements: 500 H minimum from 1 to 5 amps of 60 Hz Current.
Consider minimum current level.
For this example, the inductor must maintain 500mH minimum from 1 to 5 amperes, or
down to 20% of full-rated current (I max). The importance of this consideration is
illustrated by the graph above. This shows that, in the case of -40 Material, if the inductor
is designed to operate at 10 kG at I max, that the inductance will be greater than or equal
to L at I max down to 2.5 / 42 = 6.0% of I max. Likewise, if the inductor operates at 8 kG
at I max, the inductor can only be operated down to 4.6 / 19.5 = 25% of I max before
lower inductance will result.
Calculate Energy Storage Required (1/2 LI2
1/2 LI2 = (1/2) (500) (5) = 6250 J
Select appropriate core size.
In this example -40 Material will be used. In order to maintain a minimum inductance
down to 1 amp (20% of I max), the inductor must be designed to operate at greater than 8
http://www.micrometals.com/material/AC60HzDsgntxt.html 5/17/2017
Micrometals, Inc. - Power Cores Page 2 of 2
kG at I max. This requires a core no larger than the E137 core or T131 toroidal core. To
keep temperature rise down, the T131 will be selected.
Calculate the required Energy Storage (1/2 LI2)
1/2 LI2 = (1/2) (45) (7.5)2 = 1266 J
Determine number of turns.
At 6250 J, the T131-40 indicates 235 ampere-turns.