c Wire-guard Fitting
1.9 1 x 18W type Hi-lite WG 1018 No 32.00
1.10 1 x 36W type Hi-lite WG 1036 No 33.00
URA/Elect/SR/2005/03
SR/2
URA/Elect/SR/2005/03
SR/3
1.52 2 x 2 No 9.00
1.53 1 x 4 No 9.00
1.54 2 x 4 No 16.50
d Extra over items f, g, h and i for the following size
fitting with KSH-3E Acrylic prismatic Diffuser:
1.55 1 x 2 No 11.00
1.56 1 x 2 No 11.00
1.57 1 x 4 No 11.00
1.58 2 x 4 No 21.00
URA/Elect/SR/2005/03
SR/4
URA/Elect/SR/2005/03
SR/5
URA/Elect/SR/2005/03
SR/6
2.26 13A surface mounted metal clad switch socket outlet 2- No 20.70
gang MK 2946 ALM - ditto -
2.27 15A surface mounted metal clad switch socket outlet MK No 13.40
2873 ALM - ditto
C Mounting Boxes
2.28 32mm deep white moulded box for surface mounting type No 2.20
MK 2140 WHI or approved type including mounting and
making good of surface
2.29 32mm deep white moulded box for surface mounting type No 3.70
MK 2142 WHI or approved type including mounting and
making good of surface
2.30 35mm deep electroplated steel box for flush mounting MK No 2.00
865 ZIC - ditto -
D Accessories
2.31 5A white ceiling rose with line, neutral, earth and loop-in 4
sets of terminal MK 1161 WHI or approved type
including fixing to wall to ceiling with wood block or No 3.00
conduit box, etc, and connection
2.32 5A white lamp holder with 3 terminals MK 1171 WHI - No 3.60
ditto -
2.33 30A junction box with 3 terminals for 6mm cable No 4.80
connection MK 1130 WHI - ditto -
2.34 25A white flex outlet plate with 3 terminals for 6mm cable No 4.60
connection TENBY 5930 - ditto -
2.35 White telephone cord outlet plate, for one telephone MK No 4.70
3541 WHI or approved type including fixing to surface
moulded box or steel box
2.36 - Ditto - two telephone MK 3542 WHI - ditto - No 5.50
2.37 - Ditto - white moulded blank plate 1-gang MK 3827 WHI - No 2.20
ditto -
2.38 - Ditto - 2 gang MK 3828 MK WHI ditto No 4.20
3 STEEL AND PVC CONDUITS
(TO SUPPLY AND INSTALL THE FOLLOWING)
3.1 20mm diameter class 3 galvanised steel conduit - fixed m 3.80
onto or concealed in walls, columns or ceilings including
all necessary bends , elbows, junction boxes, circular
boxes, ties, hook and saddles, etc
3.2 25mm diameter conduit - ditto - m 4.60
3.3 32mm diameter conduit - ditto - m 6.50
3.4 20mm diameter flexible conduit - ditto - m 2.50
URA/Elect/SR/2005/03
SR/7
URA/Elect/SR/2005/03
SR/8
URA/Elect/SR/2005/03
SR/9
7
SUBMAINS/RISING MAINS/CIRCUIT WIRING IN
TRUNKING/CONDUIT/CABLE TRAY
(TO SUPPLY AND INSTALL THE FOLLOWING)
7.1 2 X 1.5mm PVC cables and 1.5mm PVC green earth m 0.70
cable in trunking/conduit or on cable tray including all
necessary clip and saddles but excluding conduit, trunking
or cable tray
7.2 2 x 2.5mm PVC cables and 2.5mm PVC ditto-. m 1.20
7.3 2 x 4mm PVC cables and 2.5mm PVC ditto - m 1.60
7.4 2 x 6mm PVC cables and 2.5mm PVC -ditto - m 2.00
7.5 2 x 10mm PVC cables and 6mm PVC -ditto - m 3.40
7.6 2 x 16mm PVC cables and 6mm - ditto- m 4.95
7.7 2 x 25mm PVC cables and 16mm PVC ditto- m 8.40
7.8 2 x 35mm PVC cables and 16mm PVC -ditto- m 11.00
7.9 4 x 2.5mm PVC cables and 2.5mm PVC-ditto-. m 2.00
7.10 4 x 4mm PVC cables and 2.5mm PVC ditto - m 2.70
7.11 4 x 6mm PVC cables and 2.5mm PVC- ditto - m 3.55
7.12 4 x 10mm PVC cables and 6mm PVC -ditto - m 6.00
7.13 4 x 16mm PVC cables and 6mm PVC -ditto - m 9.10
7.14 4 x 25mm PVC cables and 16mm PVC -ditto - m 14.80
7.15 4 x 35mm PVC cables and 16mm PVC -ditto - m 20.00
7.16 4 x 50mm PVC cables and 16mm PVC ditto-. m 25.80
7.17 4 x 70mm PVC cables and 50mm PVC ditto - m 42.70
7.18 4 x 95mm PVC cables and 50mm PVC -ditto - m 50.00
7.19 4 x 120mm PVC cables and 50mm PVC -ditto - m 65.00
7.20 4 x 150mm PVC cables and 50mm PVC - ditto - m 78.20
7.21 4 x 185mm PVC cables and 70mm PVC - ditto - m 98.70
7.22 4 x 240mm PVC cables and 70mm PVC - ditto - m 128.30
7.23 2 x 1.5mm PVC/PVC cables and 1.5mm PVC -ditto - m 0.90
7.24 2 x 2.5mm PVC/PVC cables and 2.5mm PVC ditto - m 1.40
7.25 2 x 4mm PVC/PVC cables and 2.5mm PVC -ditto - m 2.00
7.26 2 x 6mm PVC/PVC cables and 2.5mm PVC ditto - m 2.30
7.27 2 x 10mm PVC/PVC cables and 6mm PVC ditto - m 3.95
7.28 2 x 16mm PVC/PVC cables and 6mm PVC ditto - m 5.50
7.29 2 x 25mm PVC/PVC cables and 16mm PVC ditto - m 9.25
7.30 2 x 35mm PVC/PVC cables and 16mm PVC ditto - m 11.95
URA/Elect/SR/2005/03
SR/10
8 EARTH WIRING
(TO SUPPLY AND INSTALL THE FOLLOWING)
URA/Elect/SR/2005/03
SR/11
URA/Elect/SR/2005/03
SR/12
URA/Elect/SR/2005/03
SR/13
10.2 One lighting point controlled by two 2-way metal- No 43.50 55.50
clad switches (to a distance not exceeding 12m)
10.4 Each additional lighting point to item nos 10.1, 10.2 No 14.10 20.50
and 10.3 (to a (distance not exceeding 5m)
10.5 Each additional lighting point to item nos 10.1, 10.2 No 19.70 30.10
and 10.3 (to a distance exceeding 5m but not
exceeding 10m)
10.6 One fan point controlled by one metal clad switch No 36.80 48.70
including wood block for regulator but excluding
regulator (to a distance not exceeding 12m)
10.7 One lighting point controlled by one metal clad No 34.40 46.40
switch (to a distance not exceeding 12m
10.8 One lighting point controlled by two-way metal clad No 43.00 54.00
switches (to a distance not exceeding 12m)
URA/Elect/SR/2005/03
SR/14
10.10 Each additional lighting point to item nos 10.7, No 13.60 20.00
10.8 and 10.9 (to a distance not exceeding 5m)
10.11 Each additional lighting point to item nos 10.7,10.8 No 19.30 29.60
and 10.9 (to a distance exceeding 5m but not
exceeding 10m)
10.12 One fan point controlled by one metal clad switch No 36.20 48.20
including wood block for regulator but excluding
regulator ( to a distance not exceeding 12m)
10.13 One lighting point controlled by one metal clad No 36.20 48.20
switch (to a distance not exceeding 12m)
10.14 One lighting point controlled by two 2-way metal No 44.80 56.80
clad switches (to a distance not exceeding 12m)
10.16 Each additional lighting point to item nos 10.13, No 14.70 21.00
10.14 and 10.15 (to a distance not exceeding 5m)
10.17 Each additional lighting point to item nos 10.13, No 20.80 32.00
10.14 and 10.15 (to a distance exceeding 5m but
not exceeding 10m)
10.18 One fan point controlled by one metal-clad switch No 38.00 50.00
including wood block for regulator but excluding
regulator (to a distance not exceeding 12m)
URA/Elect/SR/2005/03
SR/15
10.19 One lighting point controlled by one metal clad No 35.70 47.70
switches (to a distance not exceeding 12m)
10.20 One lighting point controlled by two 2-way metal No 44.30 56.30
clad switch (to a distance not exceeding 12m)
10.21 One lighting point controlled by two 2-way switch No 62.50 78.90
and one intermediate switch (to a distance not
exceeding 20m)
10.22 Each additional lighting point to item nos 10.19, No 14.20 18.60
10.20 and 10.21 (to a distance not exceeding 5m)
10.23 Each additional lighting point to item nos 10.19, No 20.30 28.80
10.20 and 10.21 (to a distance exceeding 5m but
not exceeding 10m)
10.24 One fan point controlled by one Metal clad switch No 37.60 49.50
including wood block for regulator but excluding
regulator (to a distance not exceeding 12m)
URA/Elect/SR/2005/03
SR/16
Class 3 Class 4
Item Description Unit Conduit Conduit
Rate ($) Rate ($)
11.2 One lighting point controlled by two 2-way switch No 49.40 61.40
(to a distance not exceeding 12m)
11.3 One lighting point controlled by two 2-way switch No 77.20 95.60
and one intermediate switch (to a distance not
exceeding 20m)
11.4 Each additional lighting point to item nos 11.1, 11.2 No 19.90 26.20
and 11.3 (to a distance not exceeding 5m)
11.5 Each additional lighting point to item nos 11.1, 11.2 No 31.70 42.00
and 11.3 (to a distance not exceeding 5m but not
exceeding 10m)
11.6 One fan point controlled by one switch including No 51.20 61.40
wood block for regulator but not excluding regulator
(to a distance not exceeding 12m)
URA/Elect/SR/2005/03
SR/17
11.7 One lighting point controlled by one switch (to a No 46.20 58.10
distance not exceeding 12m)
11.8 One lighting point controlled by two 2-way switches No 62.70 72.20
(to a distance not exceeding 12m)
11.9 One lighting point controlled by two 2-way switches No 79.40 97.60
and one intermediate switch (to a distance not
exceeding 20m)
11.10 Each additional lighting point to item nos 11.7, 11.8 No 20.40 26.80
and 11.9 (to a distance not exceeding 5m)
11.11 Each additional lighting point to item nos 11.7, 11.8 No 32.80 43.20
& 11.9 (to a distance exceeding 5m but not
exceeding 10m)
11.12 One fan point controlled by one switch including No 64.50 74.10
wood block for regulator but not excluding regulator
(to a distance not exceeding 12m)
URA/Elect/SR/2005/03
SR/18
12.1 One lighting point controlled by one switch (to a distance No 33.50
not exceeding 12m)
12.2 One lighting point controlled by two 2-way switches (to a No 38.20
distance not exceeding 12m)
12.3 One lighting point controlled by two 2-way switches and No 57.40
one intermediate switch (to a distance not exceeding 20m)
12.4 Each additional lighting point to item nos 12.1, 12.2 and No 17.50
12.3 (to a distance not exceeding 5m)
12.5 Each additional lighting point to item nos 12.1,12.2 and No 23.90
12.3 (to a distance exceeding 5m but not exceeding 10m)
12.6 One fan point controlled by one switch including wood block No 27.60
for regulator but excluding regulator (to a distance not
exceeding 12m)
12.7 One lighting point controlled by one switch (to a distance No 34.80
not exceeding 12m)
12.8 One lighting point controlled by two 2-way switches (to a No 39.60
distance not exceeding 12m)
12.9 One lighting point controlled by two 2-way switches and No 59.60
one intermediate switch (to a distance not exceeding 20m)
12.10 Each additional lighting point to item nos 12.7, 12.8 and No 18.00
12.9 (to a distance not exceeding 5m)
12.11 Each additional lighting point to item nos 12.7, 12.8 and No 24.50
12.9 (to a distance exceeding 5m but not exceeding 10m)
12.12 One fan point controlled by one switch including wood block No 28.90
for regulator but excluding regulator (to a distance not
exceeding 12m)
URA/Elect/SR/2005/03
SR/19
13.1 One lighting point controlled by one switch (to a No 23.60 26.00
distance not exceeding 12m)
13.2 One lighting point controlled by two 2-way switch (to No 28.20 30.60
a distance not exceeding 12m)
13.3. One lighting point controlled by two 2-way switches No 48.50 50.90
and one intermediate switch (to a distance not
exceeding 20m)
13.4 Each additional lighting point to Item Nos. 13.1., No 10.20 12.60
13.2 and 13.3 (to a distance not exceeding 5m)
13.5 Each additional lighting point to Item Nos. 13.1, 13.2 No 17.40 19.80
and 13.3 (to a distance exceeding 5m but not
exceeding 10m)
13.6 One fan point controlled by one switch including No 30.00 32.40
wood block for regulator but not excluding regulator
(to a distance not exceeding 12m)
13.7 One lighting point controlled by one switch (to a No 25.00 27.30
distance not exceeding 12m)
13.8 One lighting point controlled by two 2-way switches No 29.50 31.90
(to a distance not exceeding 12m)
13.9 One lighting point controlled by two 2-way switches No 50.70 53.10
and one intermediate switch (to a distance not
exceeding 20m)
13.10 Each additional lighting point to Item Nos. 13.7, 13.8 No 10.80 13.10
and 13.9 (to a distance not exceeding 5m)
13.11 Each additional lighting point to Item Nos. 13.7, 13.8 No 18.50 20.90
and 13.9 (to a distance exceeding 5m but not
exceeding 10m)
13.12 One fan point controlled by one switch including No 31.30 42.90
wood block for regulator but not excluding regulator
(to a distance not exceeding 12m)
URA/Elect/SR/2005/03
SR/20
14.1 One surface conduit power point with wiring in 2 x No 34.70 44.30
2.5mm2 PVC cables and 2.5mm2 PVC green earth
cables including 20mm diameter galvanised steel
conduit pipes fixed to wall or ceiling including
saddles, hooks, and all necessary bends, elbows,
circular boxes, brass bushes, couplings and metal
clad switched socket outlet (to a distance not
exceeding 12m)
14.2 Each additional power point to Item No. 14.1 ( to a No 21.10 25.00
distance not exceeding 5m)
14.3 Same as item no. 14.1 but with 2 x 4mm2 PVC No 35.40 44.90
cables and 2.5mm2 PVC green earth cable (to a
distance not exceeding 12m)
14.4. One concealed conduit power point with wiring in 2 No 51.10 60.70
x 2.5mm2 PVC cables and 2.5mm2 PVC green
earth cable including 20mm diameter galvanised
steel conduit pipes cast in concrete or fixed to
grooves in the wall or ceiling including hacking of
grooves on walls or ceiling, saddles or hooks,
switched socket outlet, flush mounting steel box and
all necessary bends, elbows, junction boxes,
inspection bends, circular boxes, brass bushes,
coupling, etc, and making good of building works (to
a distance not exceeding 12m)
14.5 Each additional power point to Item No. 14.4 (to a No 28.70 32.70
distance not exceeding 5m)
URA/Elect/SR/2005/03
SR/21
14.8 Each additional power point to Item No. 14.7 (to a No 19.10
distance not exceeding 5m)
URA/Elect/SR/2005/03
SR/22
15.24 20A SPN metal clad surface mounting switch fuse c/w No 112.00
HRC fuse carrier but excluding HRC fuse links 'MEM'
EXEL 15KXS/C2
15.41 16A to 20A HRC cartridge fuse links 'MEM' SB3 No 2.70
15.42 25A to 32A HRC cartridge fuse links 'MEM' SB3 No 2.80
URA/Elect/SR/2005/03
SR/23
16.12 Line taps c/w feet and hexagon-headed screw for cable No 4.10
capacity of 2 x 6 mm2
16.17 BICC street lighting cutout c/w HRC fuse 25A, 240V No 37.00
URA/Elect/SR/2005/03
SR/24
URA/Elect/SR/2005/03
SR/25
URA/Elect/SR/2005/03
SR/26
URA/Elect/SR/2005/03
SR/27
URA/Elect/SR/2005/03
SR/28
URA/Elect/SR/2005/03
SR/29
URA/Elect/SR/2005/03
SR/31
A Contactor
B Time Switch
20.4 16A Quartz time clock with 150 hours reserve 'BBC' STU No 148.30
8011
C Isolator
URA/Elect/SR/2005/03
SR/32
URA/Elect/SR/2005/03
SR/33
22.1 One copper finial 500mm x 15mm diameter solid copper No 87.00
c/w base plate 'Furse'
22.3 One copper finial 1000m x 15mm diameter solid copper No 110.00
c/w base plate 'Furse'
22.6 - Ditto - precast concrete inspection pit c/w iron cover No 77.60
22.13 20mm x 3mm copper tape laid in trench 600mm deep m 20.00
including all necessary connection, excavation of trench
and reinstatement
22.17 Hot-dip Galvanised hinged lid earth inspection pit (250mm No 30.00
x 250mm)
URA/Elect/SR/2005/03
SR/34
URA/Elect/SR/2005/03
SR/35
23.24 - Ditto - for 4mm2 4/C, 6mm2 2/C, 6mm2 3/C, 6mm2 4/C No 5.60
or 16mm2 2/C PVC/SWA/PVC cables - ditto -
23.25 - Ditto - for 10mm2 2/C, 10mm2 3/C, 10mm2 4/C, 16mm2 No 8.60
3/C, 16mm2 4/C, 25mm2 2/C, 25mm2 3/C or 35mm2 2/C
PVC/SWA/PVC cables - ditto -
23.26 - Ditto - for 25mm2 4/C, 35mm2 3/C, 35mm2 4/C, 50mm2 No 12.90
2/C, 50mm2 3/C or 70mm2 2/C PVC/SWA/PVC cables -
ditto -
23.27 - Ditto - for 50mm2 4/C, 70mm2 3/C or 70mm2 4/C No 22.30
PVC/SWA/PVC cables - ditto -
24.1 50mm diameter Class 'E' PVC pipe laid in trench for road m 4.90
crossing or fixed onto wall excluding excavation and
backfilling
URA/Elect/SR/2005/03
SR/36
25.2 Supply and lay 120mm wide PVC cable slabs marked 'LT' m 1.80
3
25.13 Supply and fill cable trench with granite dust including m 27.00
necessary compaction
3
25.14 - Ditto - with crusher run including necessary compaction m 55.00
Supply and lay bituminous premix surface (any type) 2
25.15 including rolling with light and heavy rollers successively m 17.00
to a consolidated thickness of 50mm
25.16 - Ditto - 75mm thick m2 26.00
25.17 - Ditto - 100mm thick m2 34.00
25.18 Excavate trench 750mm deep x 300mm width on turf & m 10.00
backfilling including. re-turfing for cable or duct
25.19 Excavate trench 750mm deep x 300mm width on gravel m 80.00
road & backfilling c/w identification cable slab.
25.20 Ditto on metalled/concrete surface and backfilling m 150.00
Including making good c/w identification cable slabs
URA/Elect/SR/2005/03
SR/37
26.1 Erect public lighting pole not exceeding 5m high from No 42.00
ground level including excavation, cart-away debris,
making concrete foundation and collar (rate excludes
lighting pole and fitting)
26.4 - Ditto - pole exceeding 5m but not exceeding 10m high - No 90.00
ditto -
26.5 Take down existing High Pressure Discharge lamp fitted No 40.00
on lighting pole not exceeding 5m high from ground level
and replace same (rate include transportation and
collection of lamp from URA office)
26.8 Supply and turf good quality 25mm thick cow grass as
close turfing on level ground or slope not exceeding 1:2 m2 3.10
gradient including 125mm thick top soil and well watering
and tendering to ensure growth of turf.
27 REMOVAL
2.1 To remove one lighting point, fan point or power point No 7.00
including batten or conduit and wires and making good
wall or ceiling
27.2 To remove one ceiling fan, wall bracket oscillating fan or No 4.00
exhaust fan
URA/Elect/SR/2005/03
SR/38
27.5 To take down one three phase distribution board not No 15.00
exceeding 15 ways
28 MISCELLANEOUS
28.7 Single phase consumer unit of distribution fuse box not No 10.00
exceeding 15 ways including teak board
28.8 Three phase consumer unit or distribution fuse box not No 20.00
exceeding 3 x 15 ways
28.11 Supply and replace post top 400mm to 500mm diameter No 150.00
polycarbonate opal white sphere
28.13 Supply and install metal base for post top spheric lantern No 20.00
c/w mounting screws and connections
URA/Elect/SR/2005/03
SR/39
28.16 Supply and lay lean concrete (Grade 10) in foundation m3 115.00
/footing including necessary formwork
28.17 Supply and lay mass concrete (Grade 15) - Ditto - m3 130.00
28.25 Provide (0.5 x 0.5 x 0.45m) concrete square base for No 40.00
Lighted Signboard complete with bolt and nut including
excavation and making good
28.26 Supply and install stainless steel bracket (for air-con) No 165.00
28.27 Supply and install stainless steel water tray (for air-con) No 145.00
URA/Elect/SR/2005/03
SR/40
URA/Elect/SR/2005/03
SR/41
URA/Elect/SR/2005/03
SR/42
URA/Elect/SR/2005/03
SR/43
URA/Elect/SR/2005/03
SR/44
URA/Elect/SR/2005/03
SR/45
URA/Elect/SR/2005/03
SR/46
33 WEATHERPROOF OG BOXES
URA/Elect/SR/2005/03
SR/47
(a) Planted type single arm SLC 6SP NOM Each 450.00
MT HT M (6)
URA/Elect/SR/2005/03
SR/48
URA/Elect/SR/2005/03
SR/49
36 REPLACEMENT OF DEFECTIVE
STREETLIGHT COVER BOWL
URA/Elect/SR/2005/03
SR/50
37.4 Skilled electrician for checking defective wiring, per job 20.00
fuses, time switched, etc, including repair where
necessary in meter room/control box
37.6 Labour only for removal or tightening stay wire per lamp 9.00
from lamp post post
37.9 Labour for refixing loosen lamp cover/lantern per lamp 20.00
pole
37.11 Labour for refixing loosen lamp fitting per lamp 6.00
pole
37.12 Labour for dismantling single/double lamp post per lamp 28.00
arm pole
37.13 Labour for refixing single/doble arm to lamp post per lamp 28.00
pole
URA/Elect/SR/2005/03
SR/51
37.15 Labour for realigning lamp post not exceeding per lamp 45.00
4m height including all necessary excavation and pole
make good all works affected on completion
37.16 Labour for realigning lamp post exceeding 4m per lamp 73.00
but not exceeding 8m height including all pole
necessary excavation and make good all works
affected on completion
37.17 Labour for realigning lamp post exceeding 8m per lamp 85.00
but not exceeding 12m height including all pole
necessary excavation and make good all works
affected on completion
37.18 Labour for checking and locating underground per job pole 110.00
cable short-fault c/w excavation and make good
all work affected on completion
38 JOINTS
URA/Elect/SR/2005/03
SR/52
39 DRAWINGS
URA/Elect/SR/2005/03
SR/53
40.1 Prepare and paint one coat of primer and two No 4.80
coats of synthetic enamel paint onto the external
surface of 3m - 3.75m post top lighting column
40.2 Prepare and paint one coat of primer and two No 12.90
coats of synthetic enamel paint onto the external
surface of 8m post lighting column
40.3 Prepare and paint one coat of primer and two No 16.50
coats of synthetic enamel paint onto the external
surface of 10m post top lighting column
TYPE 1
URA/Elect/SR/2005/03
SR/54
Type 2
41.10 11W,9W,7W CFL with holder and cables No 22.00
Type 3
41.16 36W Lamp 32.00
43 SUPPLEMENTARY LIGHTING
(Supply and install)
43.1 3ei Spline Alliance lantern with asymmetrical reflector, No 920.00
seal safe optic system, heat treated pressed glass
diffuser c/w 150w high pressure sodium lamp and
integral control gear.
43.2.1 3ei Spline single arm mounting bracket in aluminium No 220.00
URA/Elect/SR/2005/03
SR/55
45 CABLE DETECTION
45.1 Supply labour and equipment for cable detection by
licensed cable detection worker not exceeding 4 per job 810.00
hours .
45.2 Add to the last item for each additional hour per hour 184.00
exceeding 4 hours.