Вы находитесь на странице: 1из 2

Program Version,EnergyPlus, Version 8.6.0-198c6a3cff, YMD=2017.05.

21 19:15,IDD_V
ersion 8.6.0
************* IDF Context for following error/warning message:
************* Note -- lines truncated at 300 characters, if necessary...
************* 8005 FenestrationSurface:Detailed,
************* indicated Name=Sub Surface 102
************* Only last 3 lines before error line shown.....
************* 8006 Sub Surface 102, !- Name
************* 8007 Door, !- Surface Typ
e
************* 8008 , !- Constructio
n Name
** Severe ** IP: IDF line~8008 Error detected in Object=FENESTRATIONSURFACE:
DETAILED, name=SUB SURFACE 102
** ~~~ ** Field [Construction Name] is required but was blank
************* IDF Context for following error/warning message:
************* Note -- lines truncated at 300 characters, if necessary...
************* 8633 FenestrationSurface:Detailed,
************* indicated Name=Sub Surface 66
************* Only last 3 lines before error line shown.....
************* 8634 Sub Surface 66, !- Name
************* 8635 Door, !- Surface Typ
e
************* 8636 , !- Constructio
n Name
** Severe ** IP: IDF line~8636 Error detected in Object=FENESTRATIONSURFACE:
DETAILED, name=SUB SURFACE 66
** ~~~ ** Field [Construction Name] is required but was blank
************* IDF Context for following error/warning message:
************* Note -- lines truncated at 300 characters, if necessary...
************* 8981 FenestrationSurface:Detailed,
************* indicated Name=Sub Surface 91
************* Only last 3 lines before error line shown.....
************* 8982 Sub Surface 91, !- Name
************* 8983 Door, !- Surface Typ
e
************* 8984 , !- Constructio
n Name
** Severe ** IP: IDF line~8984 Error detected in Object=FENESTRATIONSURFACE:
DETAILED, name=SUB SURFACE 91
** ~~~ ** Field [Construction Name] is required but was blank
************* IDF Context for following error/warning message:
************* Note -- lines truncated at 300 characters, if necessary...
************* 9571 FenestrationSurface:Detailed,
************* indicated Name=Sub Surface 103
************* Only last 3 lines before error line shown.....
************* 9572 Sub Surface 103, !- Name
************* 9573 Door, !- Surface Typ
e
************* 9574 , !- Constructio
n Name
** Severe ** IP: IDF line~9574 Error detected in Object=FENESTRATIONSURFACE:
DETAILED, name=SUB SURFACE 103
** ~~~ ** Field [Construction Name] is required but was blank
************* IDF Context for following error/warning message:
************* Note -- lines truncated at 300 characters, if necessary...
************* 10205 FenestrationSurface:Detailed,
************* indicated Name=Sub Surface 71
************* Only last 3 lines before error line shown.....
************* 10206 Sub Surface 71, !- Name
************* 10207 Door, !- Surface Typ
e
************* 10208 , !- Constructio
n Name
** Severe ** IP: IDF line~10208 Error detected in Object=FENESTRATIONSURFACE
:DETAILED, name=SUB SURFACE 71
** ~~~ ** Field [Construction Name] is required but was blank
************* IDF Context for following error/warning message:
************* Note -- lines truncated at 300 characters, if necessary...
************* 16458 ZoneInfiltration:DesignFlowRate,
************* indicated Name=Infiltracion_Gen_Bodefas
************* Only last 3 lines before error line shown.....
************* 16459 Infiltracion_Gen_Bodefas, !- Name
************* 16460 Gen_Bodegas_Space_type, !- Zone or Zon
eList Name
************* 16461 , !- Schedule Na
me
** Severe ** IP: IDF line~16461 Error detected in Object=ZONEINFILTRATION:DE
SIGNFLOWRATE, name=INFILTRACION_GEN_BODEFAS
** ~~~ ** Field [Schedule Name] is required but was blank
** Severe ** IP: Blank "required" fields found in input
** Severe ** IP: Out of "range" values and/or blank required fields found in
input
** Fatal ** IP: Errors occurred on processing IDF file. Preceding condition
(s) cause termination.
...Summary of Errors that led to program termination:
..... Reference severe error count=8
..... Last severe error=IP: Out of "range" values and/or blank required field
s found in input
************* Warning: Node connection errors not checked - most system inpu
t has not been read (see previous warning).
************* Fatal error -- final processing. Program exited before simulat
ions began. See previous error messages.
************* EnergyPlus Warmup Error Summary. During Warmup: 0 Warning; 0 Se
vere Errors.
************* EnergyPlus Sizing Error Summary. During Sizing: 0 Warning; 0 Se
vere Errors.
************* EnergyPlus Terminated--Fatal Error Detected. 0 Warning; 8 Sever
e Errors; Elapsed Time=00hr 00min 0.59sec