Вы находитесь на странице: 1из 1

Attempt to validate the credentials.

ADMIN GUI > MEDIA AND DEVICE MANAGEMENT > CREDENTIALS


If the validation fails
1) Verify VCenter Name or ESX is correct in the credentials.
2) Verify that the UserID is correct.
3) Verify that the "use port" number is unchecked.
4) Check to make sure that the BACKUP HOST is correctly entered
ADMIN GUI > HOST PROPERTIES > MASTER SERVER > PROPERTIES > VMWARE BACKUP HOST
5) Verify that the backup host is correctly entered
6) Verify that the backup host is in the SEVERS list of the master server.
NOTE: If only a client needs to be added to "additional servers"
7) If all this checks-out correct enable logging on the backup host.
8) Modify the following registry on the Backup Host server to gather additional
information in the NetBackup log perform the VMWare task.
Location: HKEY_LOCAL_MACHINE\SOFTWARE\VERITAS\NETBACKUP\CURRENTVERSION\CONFIG\
NEW KEY called BACKUP
NEW DWORD called vmcloglevel
MODIFY and give it a value of 3.
Create the BPVMUTIL log. Review for any errors.
9) If still not able to resolve this issue check the BACKUP HOST for hung BPVMUT
IL.exe and/or BPFIS processes. Kill any hung processes. Please note the BPFIS pr
ocess are for VMWare backup jobs. Stopping these process will cause the associat
ed running vmware job to fail.
ADDITIONAL NOTES:
VMWare client cache files are located on the backup host at \\netbackup\online_u
til\fi_cntl
Command line excution of a client refresh is \\netbackup\bin\bpvmutil 0 0 _NONE_

Вам также может понравиться