SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)

Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR RADIOGRAPHY TESTING

Date
Hull No. / Test No. 0004/14 / T-007

Job No. / Project SURFACE TARGET BARGE (STB) RMN.

LINE JOINT NO. WELDER NO. PROCESS THICKNESS


1 PT 1 001 SMAW 12 mm
2 PT 2 001 SMAW 12 mm
3 PT 3 001 SMAW 12 mm
4 PT 4 001 SMAW 12 mm
5 PT 5 001 SMAW 12 mm
6 PT 6 001 SMAW 12 mm
7 PT 7 001 SMAW 12 mm
8 PT 8 001 SMAW 12 mm
9 PT 9 002 SMAW 12 mm
10 PT 10 002 SMAW 12 mm
11 PT 11 002 SMAW 12 mm
12 PT 12 002 SMAW 12 mm
13 PT 13 002 SMAW 12 mm
14 PT 14 002 SMAW 12 mm
15 PT 15 002 SMAW 12 mm
16 PT 16 002 SMAW 12 mm
17 PT 17 003 SMAW 12 mm
18 PT 18 003 SMAW 12 mm
19 PT 19 003 SMAW 12 mm
20 PT 20 003 SMAW 12 mm
21 PT 21 003 SMAW 12 mm
22 PT 22 003 SMAW 12 mm
23 PT 23 003 SMAW 12 mm
24 PT 24 003 SMAW 12mm

Prepare By : _______________________ Certified By : ____________________


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date 12-Mar-15
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Location Of Inspection : HULL STRUCTURE BELOW MAIN DECK.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The Inspection for hull structure below main deck can be doing for check the
defect at Welding joint and all area below main deck.
Surveyor can be inspect with visual inspection and check any problem at the
below main deck.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected
Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date 18-Aug-16
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Location Of Inspection : ENGINE GIRDER PORT AND STBD.

Attention :
Mr Noor Asha bin Abdul Rashid
New Construction Manager
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The Inspection for Engine Girder can be doing for check the
defect at Welding joint of part before engine assembly at the boat.
Surveyor can be inspect with visual inspection and check any problem at the weld
joint before the Ultrasonic Testing can be do it.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Location Of Inspection : Tank hydrostatic test according to Tank Testing Plan


( Pressure Test )
Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The Inspection for tank hydrostatic have be check and test leaking
at the tank. Test can be doing with pressure testing.
Surveyor can be inspect and test with air pressure and check the gauge meter
and mark at the test document.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Location Of Inspection : Weld Joint at tight boundry of tanks


( Air Leak Test )
Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The Inspection for tank hydrostatic have be check and test leaking
at the tank. Test can be doing with pressure testing.
Surveyor can be inspect and test with air pressure and check the gauge meter
and mark at the test document.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date 17-Mar-15
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Location Of Inspection : Main Deck,Side Shell Plate (Port & STBD),Bottom Plate (Port & STB

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The Inspection and tested have be doing to looked for defect at the weld
joint .Testing can be doing with a Radiography Testing and conducted with
thirdparty representative
Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Location Of Inspection : Engine Girder.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The Inspection and tested have be doing to looked for defect at the weld
joint .Testing can be doing with a Ultrasonic Testing and conducted with thirdparty
representative.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Scope Of Inspection : Dimensional (L X B X D ) Measurement.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection for the Dimensional ( L X B X D ) Measurement to ensure the stability of
hull structure

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Scope Of Inspection : Draft Mark Inspection


Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection to ensure draft mark measure of water level at the hull body
and to ensure the stablity of boat.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART


Scope Of Inspection : Freeboard mark Inspection.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.

SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)


Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14
Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Scope Of Inspection : Bottom Survey For Launching.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Bottom survey inspection to ensure not leaking or no defect after the finish
paint the body.
The inspection of part important for the launching of boat.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :
Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.

SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)


Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com
REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL STRUCTURE PART

Scope Of Inspection : Inclining experiment / Lightship.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
To performed on a boat to determine its stability lightship weight
and the coordinated of its centre of gravity

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :
Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.

SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)


Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com
SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Date Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Hull No. / Test No. Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 SSME 003/14
Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com
Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL OUTFITTING PART

Location Of Inspection : Anchor & Chain


( Identification & Chain)

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
To inspect the identification of part followed the standard by class surveyor.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected
Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL OUTFITTING PART

Location Of Inspection : Windlass


( Installation )
Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection of part to ensure the installation true follwowing the schedule and
drawing for this part.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected
Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL OUTFITTING PART

Location Of Inspection : Hatch covers and Doors (Hose Test ).

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Hatch cover and doors to be inspect to ensure no leaking when the hose test .
the water can be spray at the hatch and doors.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL OUTFITTING PART

Location Of Inspection : Windows ( Hose Test ) .

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
To inspect the water leaking when raining and hose test will be do at the windows
after the installation.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL OUTFITTING PART

Scope Of Inspection : Life Saving, Fire Fighting equipment & Fire Protection.

1. Safety Equipment
- conformation inspection.
2. Fire fighting system
-conformation inspection.
3. A-60 insulation
-Installation inspection.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection the part to ensure the part and system safe for operation and all
installation true with schedule and condition.
Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL OUTFITTING PART

Scope Of Inspection : Accomodation space


1. Galley & Laundry Equipment.
- Operation Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection for the galley and laundry equipment to ensure the funtional
ofpart and operation test will be do with a class surveyor.
Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : HULL OUTFITTING PART

Scope Of Inspection : Air Conditioning (Split Unit )


(Operation Test )

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection of part to ensure the air conditioning funtional when the operation
will be running

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Propeller Shaft


> Material verfication & Testing.
>Final Inspection.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection of part to be ensure the material verification true and accept by
class surveyor .

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Propeller Shaft with propeller


> Contact (Blue Fitting ) Inspection.
Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The surveyor can inspection to ensure the part true with a blue fitting inspection.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT


Type of Inspection : MACHINERY PART

Location Of Inspection : Stern Tube


> Material Verification
>Final Inspection

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Surveyor can be inspect the part to ensure material true with the verification
and final inspection will be doing before operation run.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :
Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14
Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Propeller


> Material Verification & Testing.
> Final Inspection & Testing.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
To ensure the true material verification and testing by class surveyor.The surveyor
to do the final inspection and testing for the propeller before the operation run.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :
Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Rudder Assembly


> Material Verification & Testing.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Rudder Assembly inspection to be ensure the part true following the material
verification and testing by class surveyor.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor


Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Main Engine


> Safety device operation test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection to ensure the main engine can safe when the operation running
and all system will be funtional.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected
Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Electrical generator engine


> Safety device operation test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection for the electrical generator engine to check the safety device when
operation running and all system to be functional.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Steering Gear


> Hydraulic pipe pressure test
> Functional Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection to checking the funtional of steering gear whwn operation will be run
and the hydraulic pipe can be inspect with pressure testing.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Oily Water Separator


> Operation Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
To check the part can be funtional when oeration running and testing bya class
surveyor.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Sewage Treatment Plant


> Operation Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection of part to ensure the funtional system when running operation
and operation testing can be run to check the system.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Bilges System.


> Suction Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection the Bilges system to ensure bilges can functional when operation
to be running and the system will be tested with suction testing
Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : MACHINERY PART

Location Of Inspection : Quick Closing Valve For Oil Tank


> Operation Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection this part to ensure the functional of part when the operation will
be running.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : PIPING PART

Location Of Inspection : F.O Line


> Installation
> Pressure Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The piping for F.O line inspection to ensure the true installation and following
the schedule of condition.
Piping will be testing with pressure testing to detected the leaking .

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : PIPING PART

Location Of Inspection : Bilge Line.


> Installation
> Pressure Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Bilge line to be inspection to ensure the installation true followed the schedule
and testing by Pressure test.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC
CLC = to be re-inspected by class surveyor.

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT


Type of Inspection : PIPING PART

Location Of Inspection : S.W & F.W Line


> Installation
> Pressure Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection for S.W and F.W piping to be ensure true installation and piping not
leaking after the installation.
The piping can be tested with pressure testing

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :
Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14
Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : PIPING PART

Location Of Inspection : Fire Line


> Installation
> Pressure Test

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection of part to check the installation followd the schedule and listing
condition and the part can be testing with pressure test.
Pressure test to ensure the piping not leaking.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :
Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : PIPING PART

Location Of Inspection : Air Vent. & Sounding Pipe


> Installation Check.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection for the part to ensure the installation followed the schedule and
list condition.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor


Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART

Location Of Inspection : Main Generator


> Full Load Test
> Load characteristic Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Inspection for Main Generator to ensure the current supply sufficient when the
testing will be running.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected
Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART

Location Of Inspection : Main Switchboard


> Fabrication and shop test ( Interlock device,reverse power trip
test,over current trip test,high voltage test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection for this part or equipment to esure the equipment functional
when operating will be run.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART

Location Of Inspection : Battery & Battery Charging.


> Operation Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection for the battery and battery charger have to be ensure the
equipment can operated when the testing .

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART

Location Of Inspection : Motor & Control Gear.


1. Emergency stop of motor / fan
> Operation Test.
2. Monitoring Alarm System
> Operation Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
To ensure the motor and control gear to be function when operation testing
can do it.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART

Location Of Inspection : Insulation Resistance For Power Circuit.


> Measurement Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART

Location Of Inspection : Lighting Equipment.


1. Navigation and Signal Light.
> Installation.
> Function Test.
2. Emergency Light.
> Function Test.
3. Day Signal Light.
> Function Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office
Description Of Inspection :
The inspection to be ensure the installation true and function will be done after
tested.

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART

Location Of Inspection : Communication Equipment and Alarm System.


( Rudder Angle Indicator )
> Function Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office
Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART

Location Of Inspection : Navigation and Searching Equipment.


1. Horn
> Function Test.
2. Magnetic Compass.
> Function Test.
3. Gyro Compass
> Function Test.
4. Echo Sounder
> Function Test.
5. Speed Log
> Function Test.
6. Radar
> Function Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
The inspection have be doing for ensure the part in Navigation and searching
equipment can be function when tested.

Comments / Remark :
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________

_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________
_______________________________________________________________________

Result :
Accept QCC CLC Rejected
Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : ELECTRICAL PART


Location Of Inspection : Radio Equipment
1. Radio Plant
> Function Test.
2. V.H.F Telephone
> Function Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :
Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.

REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT


Type of Inspection : SEA TRIAL

Scope Of Inspection : Anchoring Test

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Kuala Lumpur Office

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected
Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.

REQUEST FOR INSPECTION


Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : SEA TRIAL

Scope Of Inspection : Speed Trial

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Kuala Lumpur Office

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected
Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : SEA TRIAL

Scope Of Inspection : Endurance Trial

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Kuala Lumpur Office

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : SEA TRIAL

Scope Of Inspection : Steering Gear Operation Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Kuala Lumpur Office

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


REQUEST FOR INSPECTION

Date
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Inspection : SEA TRIAL

Scope Of Inspection : Emergency Steering Gear Operation Test.

Attention :
Mr Muhammad Norsi B. Abdul Rahman
Marine Surveyor
Bureau Veritas Malaysia
Kuala Lumpur Office

Description Of Inspection :
Kuala Lumpur Office

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


MEMO : REPAIR FOR ENGINE GIRDER WELD JOINT.

Date 22-Jun-15
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METERS PILOT BOAT BINTULU PORT

Type of Repairing : ENGINE GIRDER WELDING JOINT.

Location Of Inspection : ENGINE GIRDER

Attention :
Staff Mzac Engineering Sdn Bhd.

Description Of Repairing :
Pembaikan /pembetulan semula sambungan welding pada tapak
enjin ini adalah untuk membolehkan ujian ultrasonic dijalankan
semula bagi mendapat keputusan dan laporan yang menepati
spesifikasi yang telah ditetapkan oleh class/surveyor.

Comments / Remark :
1. Setalah dua kali ujian ultrasonic dilakukan pada sambungan welding tapak enjin
,keputusan yang diterima adalah GAGAL.
2. Untuk itu,pembetulan /pembaikan pada sambungan welding terpaksa dibuat
semula untuk ujian kali yang ketiga.
3. Plate untuk sambungan welding tapak enjin itu hendaklah dibuat dibevel atau
single " V" .
4. Kimpalan pada sambungan hendaklah dibuat dengan kemas dan bekualiti bagi
memastikan tiada kecacatan atau kesilapan yang menyebabkan ujian ultrasonic
gagal.
Prepare By : _______________________ Certified By : ____________________
ntan

arawak

4 / T-007

BARGE (STB) RMN.

MATERIALS
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel
Mild Steel

____________
ntan

Sarawak

Mar-15
003/14

BOAT BINTULU PORT

for check the

roblem at the
urveyor
ntan

Sarawak

ug-16
003/14

BOAT BINTULU PORT

roblem at the weld


urveyor
ntan

Sarawak

003/14

BOAT BINTULU PORT

he gauge meter
urveyor
antan

Sarawak

003/14

BOAT BINTULU PORT

he gauge meter
urveyor
antan

Sarawak

Mar-15
003/14

BOAT BINTULU PORT

tom Plate (Port & STBD)

the weld
onducted with
urveyor
antan

Sarawak

003/14

BOAT BINTULU PORT

the weld
ducted with thirdparty

urveyor
antan

Sarawak

003/14

BOAT BINTULU PORT


sure the stability of

urveyor
antan

Sarawak

003/14

BOAT BINTULU PORT


he hull body

urveyor
antan

Sarawak

003/14

BOAT BINTULU PORT


urveyor
antan

Sarawak

003/14
BOAT BINTULU PORT

er the finish

urveyor
antan

Sarawak
003/14

BOAT BINTULU PORT

urveyor
antan

Sarawak
antan

Sarawak

antan

003/14
Sarawak

BOAT BINTULU PORT

ss surveyor.
urveyor
003/14

BOAT BINTULU PORT

schedule and
urveyor
003/14

BOAT BINTULU PORT

the hose test .


urveyor
003/14

BOAT BINTULU PORT

do at the windows
urveyor
003/14

BOAT BINTULU PORT

ire Protection.

ation and all


urveyor
003/14

BOAT BINTULU PORT

the funtional
urveyor
003/14

BOAT BINTULU PORT


hen the operation

urveyor
003/14

BOAT BINTULU PORT


e and accept by

urveyor
003/14

BOAT BINTULU PORT


fitting inspection.

urveyor
003/14

BOAT BINTULU PORT


he verification

urveyor
003/14
BOAT BINTULU PORT

veyor.The surveyor
e operation run.

urveyor
003/14

BOAT BINTULU PORT

g the material

urveyor
003/14

BOAT BINTULU PORT

eration running
urveyor
003/14

BOAT BINTULU PORT

ty device when
urveyor
003/14

BOAT BINTULU PORT

ration will be run


urveyor
003/14

BOAT BINTULU PORT

esting bya class


urveyor
003/14

BOAT BINTULU PORT

ning operation
urveyor
003/14

BOAT BINTULU PORT

en operation
urveyor
003/14

BOAT BINTULU PORT


peration will

urveyor
003/14

BOAT BINTULU PORT


and following

urveyor
003/14

BOAT BINTULU PORT


ed the schedule

urveyor
003/14

BOAT BINTULU PORT


and piping not

urveyor
003/14
BOAT BINTULU PORT

and listing

urveyor
003/14

BOAT BINTULU PORT

hedule and

urveyor
003/14

BOAT BINTULU PORT

cient when the


urveyor
003/14

BOAT BINTULU PORT

,reverse power trip

nt functional
urveyor
003/14

BOAT BINTULU PORT

nsure the
urveyor
003/14

BOAT BINTULU PORT

ation testing
urveyor
003/14

BOAT BINTULU PORT


urveyor
003/14

BOAT BINTULU PORT


ill be done after

urveyor
003/14

BOAT BINTULU PORT


urveyor
003/14

BOAT BINTULU PORT


and searching
urveyor
003/14

BOAT BINTULU PORT


urveyor
003/14

BOAT BINTULU PORT


urveyor
003/14

BOAT BINTULU PORT


urveyor
003/14

BOAT BINTULU PORT


urveyor
003/14

BOAT BINTULU PORT


urveyor
003/14

BOAT BINTULU PORT


urveyor
OINT.

un-15
003/14

BOAT BINTULU PORT

welding pada tapak


rasonic dijalankan
n yang menepati

welding tapak enjin

terpaksa dibuat

buat dibevel atau

dan bekualiti bagi


bkan ujian ultrasonic
____________
SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR RADIOGRAPHY TESTING

Date 17-Mar-15
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METER PILOT BOAT BINTULU PORT

LINE JOINT NO. WELDER NO. PROCESS THICKNESS MATERIALS


1 PT 1 001 FCAW 5mm Mild Steel
2 PT 2 001 FCAW 5mm Mild Steel
3 PT 3 001 FCAW 5mm Mild Steel
4 PT 4 002 FCAW 6mm Mild Steel
5 PT 5 002 FCAW 6mm Mild Steel
6 PT 6 002 FCAW 6mm Mild Steel
7 PT 7 002 FCAW 6mm Mild Steel

Prepare By : _______________________ Certified By : ____________________


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR ULTRASONIC TESTING .

Date 18-Aug-16
Hull No. / Test No. SSME 003/14

Job No. / Project 18.5 METER PILOT BOAT BINTULU PORT SDN BHD.

Type of Inspection : HULL STRUCTURE PART

Location Of Inspection & Testing : ENGINE GIRDER PORT AND STBD.

Attention : Mr. Aisamuddin B. Mohd Nor


NDT Tech.
MUKSYN ENGINEERING & SERVICES SDN BHD.
K8813/E1, Tingkat 1,BANGUNAN MPK,
24300 KERTEH,KEMAMAN,TERENGGANU
PHONE/FAX : 09- 8261949

Description Of Inspection & Testing :


1) The Inspection & Testing for Engine Girder can be doing for check the
defect at Welding joint of part before engine assembly at the boat.
2) Surveyor can be inspect with visual inspection and check any problem at the weld
joint before the Ultrasonic Testing can be do it.
3) UT man can do the UT testing at engine girder after the surveyor inspection
4) Take a result and report.

POINT & LOCATION TESTING

PORT

LINE JOINT NO. WELDER NO. PROCESS THICKNESS MATERIALS

1 P1 001 SMAW 20mm Mild Steel


2 P2 001 SMAW 20mm Mild Steel
3 P3 001 SMAW 20mm Mild Steel
4 P4 001 SMAW 20mm Mild Steel
5 P5 001 SMAW 20mm Mild Steel
6 P6 001 SMAW 20mm Mild Steel
7 P7 001 SMAW 20mm Mild Steel
8 P8 001 SMAW 20mm Mild Steel

LINE JOINT NO. WELDER NO. PROCESS THICKNESS MATERIALS

9 P9 001 SMAW 20mm Mild Steel


10 P10 001 SMAW 20mm Mild Steel
11 P11 001 SMAW 20mm Mild Steel
12 P12 001 SMAW 20mm Mild Steel
13 P13 001 SMAW 20mm Mild Steel
14 P14 001 SMAW 20mm Mild Steel
15 P15 001 SMAW 20mm Mild Steel
16 P16 001 SMAW 20mm Mild Steel

STBD

LINE JOINT NO. WELDER NO. PROCESS THICKNESS MATERIALS

1 S1 002 SMAW 20mm Mild Steel


2 S2 002 SMAW 20mm Mild Steel
3 S3 002 SMAW 20mm Mild Steel
4 S4 002 SMAW 20mm Mild Steel
5 S5 002 SMAW 20mm Mild Steel
6 S6 002 SMAW 20mm Mild Steel
7 S7 002 SMAW 20mm Mild Steel
8 S8 002 SMAW 20mm Mild Steel
9 S9 002 SMAW 20mm Mild Steel
10 S10 002 SMAW 20mm Mild Steel
11 S11 002 SMAW 20mm Mild Steel
12 S12 002 SMAW 20mm Mild Steel
13 S13 002 SMAW 20mm Mild Steel
14 S14 002 SMAW 20mm Mild Steel
15 S15 002 SMAW 20mm Mild Steel
16 S16 002 SMAW 20mm Mild Steel

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
Prepared by Testing by Witness /Reviewed By

Sign

Name

Date
h, Kelantan
o.com
ntulu, Sarawak
-P)
asir Puteh, Kelantan
d@yahoo.com
97000 Bintulu, Sarawak
myx.com

6
/14

TULU PORT SDN BHD.

r check the

any problem at the weld

surveyor inspection

RESULT
RESULT

RESULT

___________
___________
___________
___________
___________
___________
___________
___________
Witness /Reviewed By
SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR RADIOGRAPHY TESTING

Date
Hull No. / Test No.

Job No. / Project

LINE JOINT NO. WELDER NO. PROCESS THICKNESS

Prepare By : _______________________ Certified By : ____________________


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR ULTRASONIC TESTING

Date
Hull No. / Test No.

Job No. / Project

LINE JOINT NO. WELDER NO. PROCESS THICKNESS

Prepare By : _______________________ Certified By : ____________________


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

REQUEST FOR INSPECTION

Date
Hull No. / Test No.

Job No. / Project

Type of Inspection :

Location Of Inspection :

Attention :

Description Of Inspection :

Comments / Remark :
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
Result :
Accept QCC CLC Rejected

Yard Representative Class Surveyor

Signature : Signature :

Name : Name :

Date : Date :

Remarks :
QCC = to be inspected by Yard QC

CLC = to be re-inspected by class surveyor.


uteh, Kelantan
ahoo.com
0 Bintulu, Sarawak
om

STING

MATERIALS

_____________
uteh, Kelantan
ahoo.com
0 Bintulu, Sarawak
om

STING

MATERIALS

_____________
P)
sir Puteh, Kelantan
@yahoo.com
7000 Bintulu, Sarawak
yx.com

_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
lass Surveyor
SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

PILOT BOAT INSPECTION CHECKLIST


Thick appropriate box

YES

BOAT DECK

ENGINE ROOM

SUPER STRUCTURE
SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

Date
Hull No. / Test No.

Job No. / Project Pressure Test

Pressure Test Procedures

1. Purpose

The purpose of these procedures is to ensure that pressure tests are conducted safely
and effectively. They cover pressure testing of new and existing pressure systems
or components at a test pressure more than 0 psig. They apply to mechanics, supervisors,
inspectors, custodians, and subcontractors responsible for pressure tests.

2. Procedures

Pressure tests are performed to ensure the safety, reliability, and leak tightness of pressure
systems. A pressure test is required for a new pressure system before use or an existing
pressure system after repair or alteration.

There are two methods for pressure tests: hydrostatic and pneumatic. A hydrostatic test is
performed by using water as the test medium, whereas a pneumatic test uses air,
nitrogen, or any non-flammable and non-toxic gas. At PILOT BOAT, pressure tests must be
hydrostatic unless pneumatic tests can be justified.

Pressure tests must always be performed under controlled conditions, following


an approved test plan, and documented in a test record. A single approved test plan
may be used for several similar tests, but a separate test record is required for each.

2.1 Hydrostatic Test Procedure

Hydrostatic is the preferred method of pressure test at SSME


Step Person Action
Planning
1 Pipe Fitter Obtains test pressure after consulting the project engineer
Note: when hydrostatic test is performed on an existing
pressure system, the original hydrostatic test
pressure must not be exceeded.
2 Pipe Fitter Completes pressure test plan and submits for approval
3 Supervisor Approves plan.
4 Pressure systems Approves plan
program manager (not required for routine testing of existing systems)

2.2 Test Pressure

There are many types of pressure systems designed under American Society
of Mechanical Engineers (ASME) code.
The test pressure of various pressure systems must be calculated based on following.

Table 1 Test Pressures for New Pressure Vessel and Piping Systems

System Code Hydrostatic


Boiler power ASME Section I 1.5 MAWP
Boiler heating ASME Section IV 1.5 MAWP
Pressure vessel ASME Section VIII
Division 1 1.3 MAWP
Division 2 1.43 MAWP
Power piping ASME Section B31.1 1.5 design pressure
Process piping ASME Section B31.3 1.5 design pressure

MAWP: maximum allowable working pressure

3 Forms

The following forms are required by this procedure:

Pressure Systems: Pressure Test Plan Form


A detailed pressure test plan is required for every pressure test conducted at the laboratory.
An approved plan may be used for several similar tests.

Pressure Systems: Pressure Test Record Form


A separate test record is required for each pressure test.

4 Recordkeeping

The following recordkeeping requirements apply for this procedure:

The custodian of a given pressure system must maintain copies of test plans and records.

The pressure systems program manager maintains copies of all pressure test plans and
records, permanently.
SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

Pressure Test Record Form


This form is required for documenting the results of every pressure test.
Both the technician performing the test and the inspector witnessing it must sign.
A copy of the completed form must be submitted to the pressure systems program manager

Pressure Test Record no: SSME 001


Type of test: Air Pressure
Test starting time: 10.00am Test ending time:
Test Equipment Pressure Gauge Meter
Pressure range: 1.5bar

Results
Inspection: Satisfactory
Pressure test: Satisfactory

Remarks
________________________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

SHIPYARD REPRESENTATIVE OR PROJECT TEAM OR


QA/QC OFFICER OWNER REPRESENTATIVE

Signature : Signature :

Name : Name :
Date : Date :

SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)


Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

Date 7.6.2015
Hull No. / Test No. SSME 003/14

Job No. / Project Pressure Test

Pressure Test Procedures

Tujuan.

Tujuan menjalankan ujian tekanan ke atas sistem paip ini adalah untuk mengesan sebarang
kebocoran pada sambungan sistem paip dalam pilot bot.
Ujian ini hendaklah dilakukan dengan pengawasan daripada QA/QC berserta dengan pipe
fitter dan wakil daripada kakitangan bot.

Prosedur Ujian.

1. Sebelum ujian dilakukan,pipe fitter hendaklah memastikan peralatan untuk menjalankan


ujian telah disedian. Peralatan tersebut adalah
1) Kompressor
2) Hos angin
3) Meter Gauge
4) stop valve
5) spray buih sabun.

2. Jumlah tekanan udara yang akan dimasukkan kedalam paip adalah sebanyak 1.5 bar dan
tidak melebihi 2 bar.
Setelah udara bertekanan dimasukkan kedalam paip,valve akan ditutup dan dibiarkan
selama satu jam setengah.Air sabun akan disembur pada setiap sambungan bagi mengesan
kebocoran pada paip.

3. Sekiranya ada kebocoran pada mana- mana bahagian paip,ujian hendaklah dihentikan,
bahagian yang bocor hendaklah dibaiki dan ujian kebocoran akan dilakukan semula.
Jika tiada kebocoran,ujian tersebut telah berjaya dan ujian akan dijalankan pada bahagian
paip yang lain.

4. Rekod ujian yang dijalan hendaklah ditandatangan oleh QA/QC dan wakil daripada
Pilot Bot setelah ujian selesai dijalankan.

SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)


Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

Date 4.8.2015
Hull No. / Test No. SSME 001/15

Job No. / Project DYE PENETRATION TESTING

This form is required for documenting the results of every dye pentrant testing.
Both the Qc performing the test and the witnessing it must sign.

Area of Testing Results


PORT Satisfactory
CENTRE Satisfactory
STBD Satisfactory

Remarks
________________________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________
_____________________________________________________________________

SHIPYARD REPRESENTATIVE OR PROJECT TEAM OR


QA/QC OFFICER OWNER REPRESENTATIVE
Signature : Signature :

Name : Name :

Date : Date :

SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)


Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

Date 4.8.2015
Hull No. / Test No. SSME 001/15

Job No. / Project DYE PENETRATION TEST

Dye Penetration Test Procedures

Tujuan.

Tujuan menjalankan ujian adalah untuk mengesan sebarang kebocoran atau rekahan pada
plate badan kapal/bot dan juga pada kumai kimpalan.
Ujian ini hendaklah dilakukan dengan pengawasan daripada QA/QC berserta dengan wakil
daripada kakitangan kapal/bot.

Prosedur Ujian.

1. Sebelum ujian dilakukan,QA/QC hendaklah memastikan peralatan untuk menjalankan


ujian telah disedian. Peralatan tersebut adalah
1) KAIN BURUK
2) MARKER PEN
3) Dye Penetration Spray Equipment :
i) Cleaner / Remover spray
ii) Penetrant spray
iii) Developer

2. Lap tempat yang hendak diuji dengan kain buruk bagi menghilang kotoran dan sembur
cleaner/remover pada tempat yang akan diuji.Lap semula kesan cleaner/remover
tersebut.
3. Sembur Penetrant spray yang berwarna merah dan biarkan selama 5 hingga 10 minit.
Selepas itu lapkan kesan penetrant spray dengan kain buruk sehingga bersih.
4. Akhir sekali sembur Developer yang berwarna putih bagi mengesan rekahan atau
kebocoran pada plate atau kumai welding.Biarkan beberapa minit.
Kesan rekahan atau kebocoran akan nampak selepas itu dan hendaklah ditanda dengan
marker pen.
5. Tempat yang bermasalah tersebut hendaklah dibaiki semula oleh welder dan setelah
siap ianya akan diperiksa semula oleh QA/QC.
6. Rekod ujian yang dijalan hendaklah ditandatangan oleh QA/QC dan wakil daripada
Pilot Bot setelah ujian selesai dijalankan.
h, Kelantan
o.com
ntulu, Sarawak

Thick appropriate box

NO
h, Kelantan
o.com
ntulu, Sarawak

essure Test

conducted safely
ure systems
chanics, supervisors,

k tightness of pressure
e use or an existing

. A hydrostatic test is
test uses air,
essure tests must be

, following
roved test plan
quired for each.

tion

the project engineer


med on an existing
mits for approval

sting systems)

sed on following.

ucted at the laboratory.

st plans and records.

ure test plans and


h, Kelantan
o.com
ntulu, Sarawak

rm

it must sign.
ems program manager

E 001
e
11.30am
Meter
5bar

Unsatisfactory
Unsatisfactory

____________

OJECT TEAM OR
R REPRESENTATIVE
, Kelantan
com
tulu, Sarawak

7.6.2015
SSME 003/14

essure Test

uk mengesan sebarang

erserta dengan pipe

an untuk menjalankan

sebanyak 1.5 bar dan

itutup dan dibiarkan


ambungan bagi mengesan

endaklah dihentikan,
dilakukan semula.
jalankan pada bahagian
wakil daripada

h, Kelantan
o.com
ntulu, Sarawak

4.8.2015
SSME 001/15

ETRATION TESTING

nt testing.

Unsatisfactory
Unsatisfactory
Unsatisfactory

____________

OJECT TEAM OR
R REPRESENTATIVE
h, Kelantan
o.com
ntulu, Sarawak

4.8.2015
SSME 001/15

NETRATION TEST

an atau rekahan pada

erserta dengan wakil

untuk menjalankan

g kotoran dan sembur


leaner/remover

a 5 hingga 10 minit.
ngga bersih.
an rekahan atau

daklah ditanda dengan

welder dan setelah

wakil daripada
SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

WELDING MACHINE INSPECTION CHECKLIST

Name of Operator : Position :


Name of Welding Machine : Model :
Location :

DAILY CHECLIST
ITEM TO CHECKS SUN MON TUE WED THU FRI SAT REMARK
Visual check of main Electrical Switches,wiring and/or conduit
(crack,broken controls etc.)Arrange for immediate repair of any fault
Ensure workspace and walk-way clear and unobstructed
and that no slip-hazards are present

Check the welding area is free from flammables Material

Confirm availability and condition of Personal Protective


Equipment (PPE).
Check condition of welding screens at work bay are
seviceable

Ensure fume extraction unit is operating

Note : Please thick in the columm for checklist activity.

: not working / Holiday.


SEMERAK SHIPYARD & MARITIME ENGINEERING SDN BHD (728092-P)
Main Office / Main Yard : Lot 1231, Terusan Semerak, Tok Bali, 16700 Pasir Puteh, Kelantan
Tel : +609 - 778 0320 Fax : +609 - 778 0723 Email : semerak_shipyard@yahoo.com
Branch : Lot 7865, Assyakirin Commerce Centre, Jalan Sultan Iskandar, 97000 Bintulu, Sarawak
Tel : +6089 - 333 610 Fax : +609 - 333 610 Email : ssme_btu@streamyx.com

WELDING MACHINE INSPECTION CHECKLIST

WEEKLY CHECKLIST
ITEM TO CHECK 1 2 3 4 5 6 7 REMARK
Conduct close inspection for damage to switch gear test
operation of switch gear (proper funtion of switch controls
Check condition of electrode holder,electrode cable,work clamp
and work cable (check for overheating,cracks and other defects.

Check the connections for electrode cable and work cable are tight
and contact areas are clean.
Check the work clamp is securely attached to the welding materials
(A screw Clamp is preferred to a spring loaded clips)
Check availability of specific tools for this machine. (chipping
hammer,wire brush,tongs,pliers etc.)

Note : Please thick in the columm for checklist activity.

: not working / Holiday.

Prepair By :
REMARKS
REMARKS