4 Relief stream data summary


Pressure relief valves are installed on all major process equipment and the steam lines. A vacuum breaker
is also installed at the bottom of the reactor. Overpressure relief is activated if the pressure increases 10%
above the operating pressure (from a molar flow that is 10% higher than normal operation). The table
below shows the conditions of the relief streams:

Table 28: summary of relief stream data.

(vacuum breaker) Bottom of R-301/302


Top of R-301/302

HP Steam Line
E-301 gas-side

IP Steam Line
Top of V-301*
Top of E-302

Pressure (bara) 12.1 1.1 11.0 1.0 5.3 45.1 19.8


Temperature ( C ) 75.6 25 207.0 284.0 284.0 251.8 207.1
Molar flow (kmol/hr) 217.1 69.3 1,043.1 865.7 865.7 118.7 118.7
Mole Fraction
cis-butene 0.134 0.174 0.028 0.032 0.032 0 0
1-butene 0.482 0.091 0.100 0.015 0.015 0 0
trans-butene 0.335 Trace 0.070 Trace Trace 0 0
Water 0 0.459 0.792 0.749 0.749 1 1
i-butane 0.005 0.004 0.001 0.001 0.001 0 0
1,3 butadiene 0.044 0.024 0.009 0.004 0.004 0 0
2-butanol (SBA) 0 0.250 0 0.191 0.191 0 0
2,3 butanediol 0 Trace 0 0.007 0.007 0 0

*The decanter already has a venting system in place, but may also overpressure because of a temperature
excursion leading to production of higher vapour phase. This will give different compositions depending
on the temperature.