Вы находитесь на странице: 1из 4
TOPERSRGES T3OE BATES Ae GENERAL @@ ELECTRIC asoev4o : TRANSPORTATION SYSTEMS BUSINESS OPERATIONS s . le SPECIFICATION AND PROPERTIES oa nme HIGH SOLIDS PRIMER & SEALER PAINT General Electric Material A5SE140 Identifies a High Solids Primer Sealer Paint suitable for interior and exterior use over metal, painted metal and plastic. GE Designation Description ASOE 1408 Primer/Sealer Modified Alkyd Red Oxide ASOE 1408 Primer/Sealer Modified Alkyd Pink/Beige ASOE 140C Primer/Sealer Modified Alkyd Gray Low Gloss ASOE 1400 Primer/Sealer ,Modified Alkyd Gray Med.Gloss ASOE 140E Primer/Sealer Modified Alkyd Tan Med.Gloss ‘ABOE 140F Primer/Sealer Modified Alkyd Black Med.Gloss If reducer is required to adjust viscosity, use material GE Spec 05830D which identifies Solvesso 100, Aromatic #100, or a high solvency Naptha. Another solvent that can be used is GE Spec 05811, which identifies a material called Toluol or Toluene, r Finishes air dry at room temperature, however dry-time can be reduced by -.jforce drying at up to 150 deg. F for 15-20 minutes depending on part size, preceded by a 10 minute flash period. Properties of Wet Paint: AS0E140A,8,C,D,€8F Viscosity, Krebs Unit @ 25 deg C 70 +/- 10 Viscosity, # 3 Zahn Cup Read Sec. @ 25 deg C 20 +/- 5 Viscosity, # 5 Zahn Cup Read Sec. @ 25 deg C 15 +/- 5 Grind, Hegman scale, min. 5 VOC Level 1b/gal. max 3.5 Wt./Gal, Tbs. le +/- 2 Total Nonvolatiles, % by weight, min. 65 % by volume 50 +/- 2 Total Volatiles % by weight, max. 35 Coverage, sq.ft, /gal @ 1.0 dry mil, min. 770 Flash Point deg F as received Closed cup, 50 MCC Application Conditions: Paint shall be applicable by conventional airless or airspray, electro- static or heated spray techniques to yield a dry film thickness of 1.0 - 2.0 Inils for ASOE140A,B,C,D,E&F 77 Tepe | bare or warrren i itn [rrrege 19908) 1/2/87 Ry WAR Wee we alien SurERstOES 1eSUE CATED 8/28/87 GENERAL @@ ELECTRIC AS0E140 TRANSPORTATION SYSTEMS BUSINESS OPERATIONS § 3 | SPECIFICATION AND PROPERTIES = oexe== Fie HIGH SOLIDS PRIMER & SEALER PAINT Composition of Solvent: The solvents shall comply with NIOSH/OSHA requirements. Cure Conditions = Dry time @ 25 deg C, 50% RH ASOE140A,8,C,D,E&F 1 = 2 mis DFT, Minutes Dry-to handle 15 Dry-to-topcoat . 60 Referee Methods for ASOEI40 Spec and for Evaluating VOC Primer Coating-Erie Property Referee Method Criteria (1) Volatile Content ‘ASTM 2369-81 Pass (12) Salt Spray ASTM B-117 Pass (5) Settling ~ Pass (13) Impact ASTM D-2794, GE E9B3C Pass (4) Cross Hatch Adhesion GE_E9B5AZ Pass (2) Flexibility ASTM D-522-60 Pass (3) Fire Retardancy ASTM E84 Pass (7) Heldabi lity - Pass (8) Resistivity - Pass (10) Performance - Pass (9) Hold Out Test - Pass (11) Gloss/Color - Pass (6) (1) Film consisting of 1.0 - 2.0 mils of coating A,B,&C. Min. 2.0 mils for D, E, F if used by itself. Use ground one side Q-Panels, Age all panels for 7 days at 77 deg F before testing. (2) Material is reported “pas: f St of the 1/8 squares in the cross-hatch are removed by scotch 232-2"tape. (3) The coating on the .032" stee] Q-panel shall withstand a 135 deg bend over a conical mandrel without disbonding or flake-off. (hairline cracking of the coating does not constitute a failure of this test). (4) The coating shall withstand a direct forward Impact min. of 50 in.Ibs. at ey 25 deg C using a 1/2 inch (12.7 mm) dia. head and a corresponding hollow anvil. (5) The coating shall be scored through to the steel] substrate prior to testing. After 500 hours of exposure there shall be no more than 1/16" undercutting at the score line,no cracking,no flaking, no blistering beyond 1/4" from score lines, and at most scattered blistering (1/16 inch dia.) within 1/4' of score lines. (6) The gloss shall be flat, 5-12 using a 60 deg. gloss meter for ASOE140A, B,and C. The gloss for ASOE140D,E,F, shall be 25 +. on a 60 deg.meter The color shall be "A" RED OXIDE, "B" PINK/BEIGE, "C" GRAY, "D"GRAY "E"TAN, "F"BLACK fears: oF warrgen MATTAATIA —_ Tarengyeo ONTO —] 11/2/87 | ‘ev RS. MARTIN 1-10 -)] ov. ee ss comers) GENERAL QD ELECTRIC asoE140 "TRANSPORTATION SYSTEMS BUSINESS OPERATIONS $3 SPECIFICATION AND PROPERTIES =rs=ma=] TITLE, HIGH SOLIDS PRIMER & SEALER PAINT - (1) The coating shall achieve scores no greater than 15 on flame spread, fuel contribution, and smoke density when applied to 20 gauge stee. (8) Heldability should demonstrate the same weld through characteristics as primers currently used. ~\ (9) performance - should demonstrate the same physical and salt spray properties as achieved with the standard coatings. (10) Resistivity should be greater than 25 megohms CHS using a graco meter. (11) Topcoat / holdout/adhesion test - 1. prime panels 2. Topcoat after drying them 1-3-7-16-24-48-96 hours 3. The finish shall not show signs of lifting, wrinkling or loss of adhesion of the primer or topcoat. (12) Volatile Content - Use procedure "A" testing ASTM 2369-81 (13) Settling - Should not hard pack during storage and should be easily dispersed during mixing. Additional Requirements: Material shall be free from dirt, metallic particles, gelled particles, or any other contamination. Material shall cure into a hard, continuous film free from streaking, silking, grooves or channels, pockmarking, and any other film imperfections. ‘Acceptance Plan: When requested on the purchase order or otherwise specified, the supplier shall submit a Certificate of test to the QUALITY ENGINEER of General Electric Transportation Department. This Certificate shall be in triplicate showing results of tests for properties required by this specification. It shall be furnished (normally) with the shipment and addressed to the (QE) indicated on the purchase order. It shall contain the GE TSBO Dept. specification number, the drawing number ,the purchase order number, the quantity and the batch or lot number, viscosities, Zahn, VOC, % volatiles, % non-volatiles by weight, wt/gallon, and the physical test results. Final approval shall be based upon factory trial and qualification testing of the material by TS6O. The manufacturer or supplier shall not change the composition of the material approved and furnished to this specification without prior know- ledge of the GE TSB0 Department. Packaging and Marking: All material shall be packed (palletized) to prevent damage or loss during shipment and storage. Each shipping container shall be legibly marked with the product code number, the date of manufacture, the shelf life, and the j GE drawing number. fasues” 11/2/87 ey Ro MAR 8/28/87 GENERAL @@ ELECTRIC A50E140-D0 — TRANSPORTATION SYSTEMS BUSINESS OPERATIONS SPECIFICATION AND PROPERTIES S 3 tt HIGH SOLIDS PRIMER & SEALER PAINT General Electric Material ASOE140 identifies a High Solids Primer/Sealer Pain suitable for interior and exterior use over metal, painted metal, and plastic. LH 2 Ro MARTIN | oes J, Supplier GE Designation Supplier Designation Glyptal_ Advanced ‘ASOE140A c-1934 Voplex Corp. : 1400-12-6103 (41A244104MPP8) Glyptal Advanced ‘ASOE1408 c-1920 Voplex Corp. = 1400-22-1903 (4142441 04MPPS) Glyptal Advanced ‘ASOE140C c-19206 Voplex Corp. B 1400-92-0103 (41A244104MSP6) Glyptal Advanced ASOE1400 C-1968 Voplex Corp. a 1400-92-8503 (41A244104MSP7) Glyptal Advanced ASOE140E c-2028 Vopiex Corp. " 1400-72-1772 (41A244104¥KPI) Glyptal Advanced ‘ASOET40F C-2032 Voplex Corp. : 1400-72-1772 (41A244104MPP10) OF 11/2/87 | ‘ss re), PAGE 4 ON pace wees

Вам также может понравиться