General Electric Material A5SE140 Identifies a High Solids Primer Sealer
Paint suitable for interior and exterior use over metal, painted metal and
plastic.
GE Designation Description
ASOE 1408 Primer/Sealer Modified Alkyd Red Oxide
ASOE 1408 Primer/Sealer Modified Alkyd Pink/Beige
ASOE 140C Primer/Sealer Modified Alkyd Gray Low Gloss
ASOE 1400 Primer/Sealer ,Modified Alkyd Gray Med.Gloss
ASOE 140E Primer/Sealer Modified Alkyd Tan Med.Gloss
‘ABOE 140F Primer/Sealer Modified Alkyd Black Med.Gloss
If reducer is required to adjust viscosity, use material GE Spec 05830D
which identifies Solvesso 100, Aromatic #100, or a high solvency Naptha.
Another solvent that can be used is GE Spec 05811, which identifies a material
called Toluol or Toluene,
r Finishes air dry at room temperature, however dry-time can be reduced by
-.jforce drying at up to 150 deg. F for 15-20 minutes depending on part size,
preceded by a 10 minute flash period.
Properties of Wet Paint:
AS0E140A,8,C,D,€8F
Viscosity, Krebs Unit @ 25 deg C 70 +/- 10
Viscosity, # 3 Zahn Cup Read Sec. @ 25 deg C 20 +/- 5
Viscosity, # 5 Zahn Cup Read Sec. @ 25 deg C 15 +/- 5
Grind, Hegman scale, min. 5
VOC Level 1b/gal. max 3.5
Wt./Gal, Tbs. le +/- 2
Total Nonvolatiles,
% by weight, min. 65
% by volume 50 +/- 2
Total Volatiles
% by weight, max. 35
Coverage, sq.ft, /gal @ 1.0 dry mil, min. 770
Flash Point deg F as received Closed cup, 50
MCC
Application Conditions:
Paint shall be applicable by conventional airless or airspray, electro-
static or heated spray techniques to yield a dry film thickness of 1.0 - 2.0
Inils for ASOE140A,B,C,D,E&F
77 Tepe |
bare or warrren i itn [rrrege
19908) 1/2/87 Ry WAR Wee we
alienSurERstOES 1eSUE CATED
8/28/87 GENERAL @@ ELECTRIC AS0E140
TRANSPORTATION SYSTEMS BUSINESS OPERATIONS § 3
| SPECIFICATION AND PROPERTIES = oexe==
Fie HIGH SOLIDS PRIMER & SEALER PAINT
Composition of Solvent:
The solvents shall comply with NIOSH/OSHA requirements.
Cure Conditions
= Dry time @ 25 deg C, 50% RH ASOE140A,8,C,D,E&F
1 = 2 mis DFT, Minutes
Dry-to handle 15
Dry-to-topcoat . 60
Referee Methods for ASOEI40 Spec and for Evaluating VOC Primer Coating-Erie
Property Referee Method Criteria (1)
Volatile Content ‘ASTM 2369-81 Pass (12)
Salt Spray ASTM B-117 Pass (5)
Settling ~ Pass (13)
Impact ASTM D-2794, GE E9B3C Pass (4)
Cross Hatch Adhesion GE_E9B5AZ Pass (2)
Flexibility ASTM D-522-60 Pass (3)
Fire Retardancy ASTM E84 Pass (7)
Heldabi lity - Pass (8)
Resistivity - Pass (10)
Performance - Pass (9)
Hold Out Test - Pass (11)
Gloss/Color - Pass (6)
(1) Film consisting of 1.0 - 2.0 mils of coating A,B,&C. Min. 2.0 mils for D,
E, F if used by itself. Use ground one side Q-Panels, Age all panels for
7 days at 77 deg F before testing.
(2) Material is reported “pas: f St of the 1/8 squares in the cross-hatch
are removed by scotch 232-2"tape.
(3) The coating on the .032" stee] Q-panel shall withstand a 135 deg bend
over a conical mandrel without disbonding or flake-off. (hairline
cracking of the coating does not constitute a failure of this test).
(4) The coating shall withstand a direct forward Impact min. of 50 in.Ibs. at
ey 25 deg C using a 1/2 inch (12.7 mm) dia. head and a corresponding hollow
anvil.
(5) The coating shall be scored through to the steel] substrate prior to
testing. After 500 hours of exposure there shall be no more than 1/16"
undercutting at the score line,no cracking,no flaking, no blistering
beyond 1/4" from score lines, and at most scattered blistering (1/16 inch
dia.) within 1/4' of score lines.
(6) The gloss shall be flat, 5-12 using a 60 deg. gloss meter for ASOE140A,
B,and C. The gloss for ASOE140D,E,F, shall be 25 +. on a 60 deg.meter
The color shall be "A" RED OXIDE, "B" PINK/BEIGE, "C" GRAY, "D"GRAY
"E"TAN, "F"BLACK
fears: oF warrgen MATTAATIA —_ Tarengyeo ONTO —]
11/2/87 | ‘ev RS. MARTIN 1-10 -)] ov. ee
sscomers) GENERAL QD ELECTRIC asoE140
"TRANSPORTATION SYSTEMS BUSINESS OPERATIONS $3
SPECIFICATION AND PROPERTIES =rs=ma=]
TITLE, HIGH SOLIDS PRIMER & SEALER PAINT
-
(1) The coating shall achieve scores no greater than 15 on flame spread, fuel
contribution, and smoke density when applied to 20 gauge stee.
(8) Heldability should demonstrate the same weld through characteristics as
primers currently used.
~\ (9) performance - should demonstrate the same physical and salt spray
properties as achieved with the standard coatings.
(10) Resistivity should be greater than 25 megohms CHS using a graco meter.
(11) Topcoat / holdout/adhesion test - 1. prime panels 2. Topcoat after drying
them 1-3-7-16-24-48-96 hours 3. The finish shall not show signs of
lifting, wrinkling or loss of adhesion of the primer or topcoat.
(12) Volatile Content - Use procedure "A" testing ASTM 2369-81
(13) Settling - Should not hard pack during storage and should be easily
dispersed during mixing.
Additional Requirements:
Material shall be free from dirt, metallic particles, gelled particles,
or any other contamination.
Material shall cure into a hard, continuous film free from streaking,
silking, grooves or channels, pockmarking, and any other film imperfections.
‘Acceptance Plan:
When requested on the purchase order or otherwise specified, the supplier
shall submit a Certificate of test to the QUALITY ENGINEER of General Electric
Transportation Department. This Certificate shall be in triplicate showing
results of tests for properties required by this specification. It shall be
furnished (normally) with the shipment and addressed to the (QE) indicated on
the purchase order. It shall contain the GE TSBO Dept. specification number,
the drawing number ,the purchase order number, the quantity and the batch or
lot number, viscosities, Zahn, VOC, % volatiles, % non-volatiles by weight,
wt/gallon, and the physical test results.
Final approval shall be based upon factory trial and qualification
testing of the material by TS6O.
The manufacturer or supplier shall not change the composition of the
material approved and furnished to this specification without prior know-
ledge of the GE TSB0 Department.
Packaging and Marking:
All material shall be packed (palletized) to prevent damage or loss
during shipment and storage. Each shipping container shall be legibly marked
with the product code number, the date of manufacture, the shelf life, and the
j GE drawing number.
fasues” 11/2/87
ey Ro MAR8/28/87
GENERAL @@ ELECTRIC
A50E140-D0
—
TRANSPORTATION SYSTEMS BUSINESS OPERATIONS
SPECIFICATION AND PROPERTIES
S 3
tt
HIGH SOLIDS PRIMER & SEALER PAINT
General Electric Material ASOE140 identifies a High Solids Primer/Sealer Pain
suitable for interior and exterior use over metal, painted metal, and plastic.
LH
2 Ro MARTIN | oes J,
Supplier GE Designation Supplier Designation
Glyptal_ Advanced ‘ASOE140A c-1934
Voplex Corp. : 1400-12-6103
(41A244104MPP8)
Glyptal Advanced ‘ASOE1408 c-1920
Voplex Corp. = 1400-22-1903
(4142441 04MPPS)
Glyptal Advanced ‘ASOE140C c-19206
Voplex Corp. B 1400-92-0103
(41A244104MSP6)
Glyptal Advanced ASOE1400 C-1968
Voplex Corp. a 1400-92-8503
(41A244104MSP7)
Glyptal Advanced ASOE140E c-2028
Vopiex Corp. " 1400-72-1772
(41A244104¥KPI)
Glyptal Advanced ‘ASOET40F C-2032
Voplex Corp. : 1400-72-1772
(41A244104MPP10)
OF 11/2/87 | ‘ss re), PAGE 4 ON pace
wees