Вы находитесь на странице: 1из 8

measuring

Totalising, Dosing and

Monitoring Electronics monitoring



pulse input analysing

ZOK

LCD-display, background lighting


2
pulse inputs
2" pipe mounting kit (NPN, PNP, NAMUR, reed switch etc.)

Analogue, switching, pulse, relay output,
status output

P?
Z2
Sensor supply
Free scaling

Universal housing, panel mounting or
field housing

Wall mounting kit

KOBOLD companies worldwide: KOBOLD Messring GmbH


Nordring 22-24
ARGENTINA, AUSTRIA, AUSTRALIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLoMBIA, D-65719 Hofheim/Ts.
CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, Head Office:
MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, ROMANIA, SINGAPORE, SOUTH KOREA, +49(0)6192 299-0
+49(0)6192 23398
SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, turkey, USA, VIETNAM info.de@kobold.com
1/05-2017

www.kobold.com

1
Totalising, Dosing and Monitoring Electronics Model ZOK

Technical Details
External power supply: 5...28 VDC (without using the
analogue output)
8...28 VDC (with using the
analogue output)
12...28 VDC with relay output
max. power consumption:
with DC supply voltage approx.
70 mA (with full
backlight, without outputs)
See table on page 7 for details
Battery (battery for
operation): 3.6 V/2200 mAh
Lithium size AA
Description Battery life in battery mode: dependant on the chosen sleep
The electronic units ZOK-Xx are specifically designed for mode
the calculation, display and transfer of calculations and max. 17 months
flow rates of flow meters with pulse or frequency outputs. min. 3 months
The instruments display flow rate, day counter (resettable) Display: LCD, graphic 128x64,
and total counter in the operator-selected units. A clear backlight adjustable (only with
multilingual menu guides you through the programming of external supply)
the device that largely eliminates the requirement of constant Size of main display value: 12.5 mm
usage of operating manual. All user-specific program settings
Display resolution of main
are retained even when changing the battery.
display value: 5 digits, based on measuring
The electronics options ZOK-ZxK are weather resistant range end value
and adequately reflect IP66/67 (NEMA 4X). The electronics
Engineering units
is housed in a UV-resistant, glass-filled nylon housing with
displayed: litres, millilitres, gallons (US or
stainless steel screws and FPM seals.
UK), barrel, m3, user defined
The option ZOK-ZxP is in a panel housing 96x96 mm with engineering units displayed
protection class IP44. The option ZOK-ZxF is available in
powder coated aluminum extruded housing with plastic lids Input scaling range: 0.001...99,999.999 with
and appropriate protection class IP66/67. The instruments 3 floating decimal points
are suitable for harsh indoor or outdoor environments and Mounting: meter mount, wall, surface, pipe
comply with EU Directive 2004/108/EC (Electromagnetic or panel mount, field mount
Compatibility).
Measuring inputs: 2 x pulse input, type: NPN,
PNP, NAMUR, Reed, Hall, acti-
Significant Characteristics ve (configurable with software)
Battery life or external powered, graphic LCD-display Input frequency: 0.1...1000 Hz,
resettable and cumulative totaliser, 5 digit main value High-Low-threshold 1 VDC,
display, configurable max. Input amplitude 30 VDC
Robust field or panel mountable housing Basic accuracy of flow
Simple programming measurement: <0.1 % of reading
(the accuracy of the displayed
Universal pulse inputs
value depends on the adjusted
Display backlighting scale and display resolution)
Status output Sensor supply: 8 VDC, max. 30 mA
Scalable pulse output (with external supply >10 VDC)
Optional: wall or pipe mounting Arithmetic functions: A+B, A-B with scalable ana-
logue output
1/05-2017

2 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Outputs Relay outputs: potential-free changeover


Status output: transistor output, Push-Pull contacts, max. switching
(PP), max. 300 mA, voltage 230 VAC/DC,
overload protection max. current load dependent
Relay outputs (only -Z2): potential-free changeover (see diagram)
contacts, max. switching Analogue output
voltage 230 VAC/DC, max. current (at ZOK-Z3P): 4-20 mA, 3-wire,
load dependent (see diagram) current source
Optocoupler output Housing: ZOK-ZxP panel mounted,
(only E2/E5): max. switching voltage: 30 VDC 96x96 mm, depth 60 mm
RON=1700 , ROFF >10 G degree of protection front IP65,
to be used with NAMUR-isola- backside IP20
ted switching amplifier ZOK-ZxF aluminium housing
Switching outputs: transistor output PNP, NPN or with plastic lid PA6
Push-Pull (PP), with software 117 x 117 mm, depth 127 mm
configurable, Protection: IP65
max. output current: 300 mA Cable entry: 3xM16x1.5/2xPG13.5 for
(source/sink), ZOK-ZxF
overload protection 3xscrew terminals for ZOK-ZxP
Pulse output: transistor output, Push-Pull Retention of meter readings
(PP), max. 300 mA, in case of power failure: in integrated, non-volatile
overload protection memory
Analogue output: 4-20mA, 2-conductor loop Ambient temperature: -20...+80C
operation or 3-wire operation
(current source or sink)
selectable by external wiring, Max. DC load breaking capacity
free scaling,
max. load: 750 at 24 VDC,
250 at 14 VDC,
150 at 12 VDC,
Resolution: 16 bits
Operation: 4 buttons
Housing: plastic, PA6, GF-enhanced
Protection: IP66/67 (not for panel
mounting)
Cable entry: 3xM20x1.5 or " NPT
(prepared, not for panel
mounting device)
Electrical connection: plug-in terminals
ATEX Certification: II 2G Ex ia IIC T4 Gb
IECEx Certification: Ex ia IIC T4 Gb
Ambient temperature: ZOK-Z: -20...+80C
ZOK-E: -20+60C

Additional Data for Options ZOK-ZxP and ZOK-ZxF


Power supply: 12...28 VDC (supply option -6)
90-260 VAC (supply option -0)
battery operation only with
ZOK-ZxF with supply option 3
See table on page 7 for details
Sensor supply: 8V with supply voltage 8,5VDC
(supply option -3)
8 V or 24V selectable (supply
option -0 and 6)
1/05-2017

No responsibility taken for errors; www.kobold.com 3


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Instrument/Functions overview ZOK...

Function Z1P/Z1F Z1K/M Z2P/Z2F Z2K/M Z3P/Z3F Z3K/M E1K/M E2K/M E3K/M E4K/M E5K/M

Dual counter X X X X X X X X

Dosing function X X X

Controller function X X X X X

Certification

ATEX
X X X X X
Certification

Power supply

DC-supply X X X X X X X X X X X

AC-supply X X X

Battery operation X X X X X

Sensor supply (only with external power supply)

8 V/ 8 V/ 8 V/
Sensor supply 8V 8V 8V 8V 8V 8V 8V 8V
24 V 24 V 24 V

Electrical outputs (only with external supply)

with with
opto opto
Relay outputs X X X
coupler coupler
board* board*

Status outputs X X X X X X

2L/ 2L/ 2L/3L


Analogue outputs 3L 3L
3L 3L HART
with
opto
Pulse outputs X X
coupler
board*

LCD-display

Selectable units X X X X X X X X X X X

Decimal point X X X X X X X X X X X

Accumulative total X X X X X X X X X X X

Resettable total X X X X X X X X X X X

Linearisation X X X X X X X X X

Rate display X X X X X X X X X X X

Backlighting X X X X X X
Arithmetic
X X X X X X X X X
functions
* Optocoupler board serves as a galvanic separation to be used in ATEX area
1/05-2017

4 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Display
Display layout in measuring mode single channel (ZOK-Z1/E1/Z3/E3/E4/E5)

part- or total volume display input A

part- or total volume counter input A

unit associated to main display

volume flow display input A

part- or total volume counter input A

unit associated to main display


1/05-2017

No responsibility taken for errors; www.kobold.com 5


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Display (continued) supply type (ext/bat) status output


Display layout in measuring
mode for dual channel
(ZOK-Z1/E1/Z3/E3/E4/E5)
part volume display input A

part volume display input B

volume flow display inputs A and B


(alternating)

unit associated to main display


over- and underrun display input B
over- and underrun display input A
status and type input B
status and type input A

supply type (ext/bat)


status switch outputs
status pulse output
status output

volume flow display input A

volume flow display input B

part- or total volume counter inputs A and B


(alternating)

unit associated to main display


over- and underrun display input B
over- and underrun display input A
status and type input B
status and type input A

ZOK-Z2/E2 (Dosing unit) supply type (ext)


status switch outputs
status output

over- and underrun display


input A dosing volume display

batch counter
volume flow display

start dosing
reset dosing volume
set dosing volume
status and input type A
1/05-2017

6 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Order Details (Example: ZOK-Z1 K M F 3 0 0)


Electrical
Model Electronics Housing type connection/ Input Power supply Options Special
cable gland
Z1 = dual totaliser LCD
Z22) = dosing unit LCD
Z3 = rate totaliser LCD, K = universal
4-20 mA, mount
4-20 mA HART (standard,
M3) = 3 x M20x1.5
E1 = as Z1 with ATEX round plastic
cable entry
approval with holder 0 = without 0 = without
plates) 2 3)
= 3 x " NPT
E22) = as Z2 with ATEX 32) = 5...28 VDC, R2) = 2 relays Y = special
cable entry F = pulse/
approval M = universal battery G7) = 2xopto- (please
ZOK- mount K9) = terminal on frequency 2)
E3 = as Z3 with ATEX 0 = 90...260 VAC coupler specify
(round plastic the back input
in clear
approval 4-20 mA, 62) = 12...28 VDC, P8) = 3xopto-
for retrofitting N 4)
= 3
 xM16x1.5 text)
without pulse- and cable entry coupler
switching outputs DON)
P = panel mount
1) P 4)
= 2xPG13,5
E45) = as E3 with HART
96x96
E56) = as E3 with
4-20 mA and F1) = field housing
pulse- and switching
outputs
1)
Not for ZOK-E1, E2, E3, E4 and E5 2) See table below 3) Only for housing ZOK-xxK, ZOK-xxM 4)
Only for ZOK-ZxF 5)
In preparation
6)
Option E5 possible only with remote I.S.isolator 7) Standard for ZOK-E2 8) Standard for ZOK-E5 9)
For ZOK-ZxP

Overview of electrical options and corresponding housings


Model Electronics Housing Supply voltage Relay option Opto-coupler
Option Battery option
K
3 standard
M
Z1 P 6/0 no no
yes (with voltage
F 3/0
option 3)
K
6
M
Z2 no standard
P no
ZOK 6/0
F
K
3/6 yes (with option 3) yes (with option 6)
M
Z3 P 6/0 no standard
3 standard no
F
6/0 no standard
E1/E3/E41) K/M 3 standard
no
E2/E51) K/M 3 no standard
1)
Without backlighting

Accessories

Description Model

Stainless steel wall mounting kit ERS-ZOK-023618

Stainless steel 2" pipe mounting kit ERS-ZOK-003402

Cooling fin for high temperature flowmeter ERS-ZOK-023619

Batterypack ATEX, 3,6 V ERS-BATEX036

ERS-BATEX036 is part of standard scope of delivery of ZOK-E1/E3/E4


1/05-2017

No responsibility taken for errors; www.kobold.com 7


subject to change without prior notice.
Totalising, Dosing and Monitoring Electronics Model ZOK

Dimensions [mm]

ZOK-ExK/-ZxK

ZOK-ExM/-ZxM

ZOK-ZxP
7 56

96,4

96,4 56,4

ZOK-ZxF

127 117
3xM16x1.5
34
117

91
1/05-2017

8 www.kobold.com No responsibility taken for errors;


subject to change without prior notice.

Вам также может понравиться