Вы находитесь на странице: 1из 6

ComFlor 46/1.

2/S280 BS 5950 Parts 4, 6 and 8 Page 1 of 6

SCI Tata Steel v9.0.22.0


JOB REFERENCE: NOVO CINEMA Date: 1/8/2015
DECK REFERENCE: CF46/1.2_280 Time: 12:07:22
COMPANY NAME: Job No.:
CLIENT NAME:
FILENAME: Calcs by: Checked by:

FULL OUTPUT

NOTE: SECTION DESIGNED TO BRITISH STANDARDS


Construction Stage: PASS Max Unity Factor = 0.46
Normal Stage: PASS Max Unity Factor = 0.18
Fire Condition: PASS Max Unity Factor = 0.37
Serviceability: SATISFACTORY Max Unity Factor = 0.19

*** SECTION ADEQUATE ***


FLOOR PLAN DATA : (unpropped composite construction with ComFlor 46/1.2/S280 decking)
Beam centres - equal 1.90 m Span type DOUBLE
Beam or wall width 152 mm Propping NONE
PROFILE DATA : (ComFlor 46/1.2/S280 decking)
Depth 46 mm Pitch of deck ribs 225 mm
Trough width 105 mm Crest width 67.0 mm
Nominal sheet thickness 1.20 mm Design sheet thickness 1.16 mm
Deck weight 0.13 kN/m Yield strength 280 N/mm
CONCRETE SLAB : [Normal Weight Concrete ; Mesh : A193]
Overall slab depth 165 mm
Concrete characteristic strength 40 N/mm Concrete wet density 2400 kg/m
Modular ratio 10 Concrete dry density 2350 kg/m
Bar reinforcement NONE
Mesh reinforcement :
Mesh A193 Yield strength 460 N/mm
Cover to Mesh 30 mm Mesh Layers Single
Account for End Anchorage NO Shear connectors per rib N/A
Diameter of Shear Connectors N/A
Screeds N/A
SECTION PROPERTIES :
***NOTE - 1: All values of inertia are expressed in steel units
***NOTE - 2: Average inertia is used for deflection calculations for the composite stage
***NOTE - 3: Cracked dynamic inertia is used for natural frequency calculations
DECK PROFILE:
Sagging Inertia, Ixx 53.000 cm4/m Area of profile (Net), Ap 1534 mm/m
Hogging Inertia, Iyy 0.000 cm4/m

File Name: v9.0.22.0


ComFlor 46/1.2/S280 BS 5950 Parts 4, 6 and 8 Page 2 of 6

COMPOSITE:
Inertia, Ixx - Uncracked 3624 cm4/m Cracked 1835 cm4/m

Average inertia 2730 cm4/m Cracked inertia (dynamic) 2077 cm4/m

Shear bond coefficients - Mr 86.80 Kr 0.039600

Concrete volume 0.146 m/m/m

LOADS ACTING ON SLAB :


*** NOTE: Slab subjected to uniformly distributed loads (UDL) ONLY

Imposed (occupancy) 5.00 kN/m Partitions 1.00 kN/m

Ceilings and services 0.50 kN/m Finishes 0.50 kN/m

Self weight of concrete slab (wet) 3.43 kN/m Self weight of decking 0.13 kN/m

Self weight of concrete slab (dry) 3.36 kN/m Screeds NONE

Construction load 2.4 kN/m

LINE LOADS PERPENDICULAR TO DECK SPAN :


None

LINE LOADS PARALLEL TO DECK SPAN :


None

FIRE DATA :
Design method SIMPLE Fire resistance period 120 mins

Non-permanent imposed loads 0.0 kN/m

PARTIAL SAFETY FACTORS :


Dead (self weight) 1.40 Imposed 1.60

Super imposed dead 1.40 Fire (occupancy loads) 0.80

File Name: v9.0.22.0


ComFlor 46/1.2/S280 BS 5950 Parts 4, 6 and 8 Page 3 of 6

CONSTRUCTION STAGE
LOADINGS Unfactored(kN/m) Factored(kN/m)
Self weight of decking 0.13 0.18
Self weight of concrete slab (wet) 3.43 4.81
Construction load (one span) 2.37 3.79
Construction load (adjacent span(s)) 0.79 1.26
Total factored load (maximum) = 0.18 + 4.81 + 0.00 + 3.79
= 8.78 kN/m
EFFECTIVE SPAN OF DECK :
Effective span Le, is the smaller of
1) c/c of supports = 1.90 m
2) clear span + deck depth = 1.75 + 46.0 / 1000
= 1.79 m
Therefore Le = 1.79 m
SHEAR RESISTANCE CHECK :
*** Check at first interior support position
Applied shear = [1.250 * 0.18 + 1.250 * 4.81 + 1.250 * 0.05 + 2.500 * 3.79/3] * 1.79 / 2
= 8.48 kN/m
Shear strength of decking, pv = 168.0 N/mm
Shear resistance, Pv = 79.7 kN/m
UNITY FACTOR = 0.11 PASS
WEB CRUSHING RESISTANCE CHECK :
*** Check at first interior support position
Applied reaction 16.96 kN/m
Web crushing resistance, Pw 68.99 kN/m
UNITY FACTOR = 0.25 PASS
BENDING RESISTANCE CHECK :
NOTE: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
SAGGING:
Max applied moment = [0.070 * 0.18 + 0.096 * 4.81 + 0.096 * 0.05 + 0.096 * 3.79] * 1.79^2
= 2.71 kNm/m
Moment resistance, Mc = 5.99 kNm/m
UNITY FACTOR = 0.45 PASS
HOGGING:
Max. applied moment = 2.13 kNm/m
Moment resistance, Mc = 6.23 kNm/m
UNITY FACTOR = 0.34 PASS
INTERACTION OF BENDING MOMENT AND SHEAR :
NOTE 1: *** Check at first interior support position
NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied shear = 7.97 kN/m
Shear resistance, Pv = 79.68 kN/m
Applied moment = 2.13 kNm/m
Moment resistance, Mc = 6.23 kNm/m
UNITY FACTOR = [7.97/79.68]^2 + [2.13/6.23]^2
= 0.13 PASS

File Name: v9.0.22.0


ComFlor 46/1.2/S280 BS 5950 Parts 4, 6 and 8 Page 4 of 6

INTERACTION OF BENDING MOMENT AND WEB CRUSHING :

NOTE 1: *** Check at first interior support position


NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied reaction = 15.95 kN/m
Web crushing resistance, Pw = 79.68 kN/m
Applied moment = 2.13 kNm/m
Moment resistance, Mc = 6.23 kNm/m
UNITY FACTOR = [15.95/68.99 + 2.13/6.23]
= 0.57 < 1.25 PASS
DEFLECTION CHECK :

Allowable deflection max, is the lesser of


1) Effective span/180 (= 10.0 mm ), and
2) 20 mm ( absolute maximum value ), and
3) Slab depth/10 = ( 16.5 mm )
Max. self weight deflection = 1.85 mm
( < 9.97 mm ) SATISFACTORY
***NOTE: Deflection within code limits; ponding is not considered

File Name: v9.0.22.0


ComFlor 46/1.2/S280 BS 5950 Parts 4, 6 and 8 Page 5 of 6

NORMAL STAGE

LOADINGS : (see construction load calculations for details):


Unfactored (kN/m) Factored (kN/m)
Dead 0.13 + 3.36
= 3.49 4.89
Imposed 5.00 + 1.00
= 6.00 9.60
Superimposed dead 0.50 + 0.50 + 0.00
= 1.00 1.40
Total = 10.49 kN/m 15.89 kN/m
EFFECTIVE SPAN :
Effective span Le, is the smaller of
1) c/c of supports
2) clear span + slab overall depth - depth to centroid = 1.75 + 165 / 1000 - 20.44 / 1000
= 1.89 m
Therefore Le = 1.89 m
SHEAR RESISTANCE CHECK :
Maximum applied shear = 0.5 * 15.89 * 1.89
= 15.08206
Shear stress in concrete, v = 0.18 N/mm
Shear strength of concrete, vc = 0.97 N/mm
Shear resistance = 131.50 * 144.56 * 0.97 / 225.00
= 82.16 kN/m
UNITY FACTOR = 0.18 PASS
PUNCHING SHEAR CHECK :
Not Applicable
SHEAR BOND RESISTANCE CHECK :
Shear span = 1.89 / 4
= 0.47 m
Applied shear = 10.41 kN/m
Shear bond resistance = (1000 * 144.56/1.25) * [86.80 * 1534.00 / (1000 * {0.47 * 1000} + 0.04 * 40.00)]
/ 1000 kN/m
= 61.51 kN/m
Anchorage resistance = 0 kN/m
Total shear resistance = (61510.01/1000) + [(0/1000)]/2 = 61.51 kN/m
UNITY FACTOR = 0.17 PASS
BENDING RESISTANCE CHECK :
Applied bending moment = 0.125 * 15.89 * 1.89^2
= 7.14 kNm/m
Depth of concrete stress block = 22.19 mm
NOTE: depth of concrete in compression may be limited to 0.45 ds
Tension in decking = 399.45 kN/m
Tension in bar reinforcement = 0.00 kN/m
Depth to position of resultant tension = (0.0 * 135.0 + 399.5 * 144.6) / (0.0 + 399.5)
= 144.56 mm
Lever arm = 133.46 mm
NOTE: lever arm may be limited to 0.95 ds
Compression in concrete
= 399.45 kN/m
Moment resistance = 399.45 * 133.46/1000
= 53.31 kNm/m
UNITY FACTOR = 0.13 PASS

File Name: v9.0.22.0


ComFlor 46/1.2/S280 BS 5950 Parts 4, 6 and 8 Page 6 of 6

FIRE RESISTANCE CHECK :


Effective span in fire, is the greater of
1) c/c suppports - support width = 1.90 - 152 / 1000
= 1.75 m
2) c/c supports - 150 = 1.90 - 150 / 1000
= 1.75 m
i.e effective span in fire = 1.75 m
Fire dead load = 0.13 + 3.36 + 0.50 + 0.50 + 0.00
= 4.56 kN/m
Non-permanent fire imposed load = 0.80 * 0.0 *5.00
= 0.0 kN/m
Permanent fire imposed load = (1 - 0.0) *5.00 + 1.00
= 6.00 kN/m
Fire imposed load = 0.00 + 6.00
= 6.00 kN/m
Fire free moment = 4.04 kNm/m
Moment resistance, sagging = 5.45 kNm/m
Moment resistance, hogging = 12.84 kNm/m
Moment resistance, Mr = 5.45 + 0.45 * 12.84 *** for end span
= 10.93 kNm/m
UNITY FACTOR = 0.37 PASS
As spans are approximately equal, no check on uplift at an external support has been made
DEFLECTION CHECK :
Allowable deflection max-i under imposed loads, is the lesser of
1) Effective span/350 (= 5.4 mm ), and
2) Absolute maximum value (mm) = 20
Imposed load deflection = 0.013 * 6.50 * (1.89* 1000 )^4 / (205*27297130 )/1000
= 0.2 mm ( < 5.4 mm ) SATISFACTORY
Allowable total deflection max-t, is the lesser of
1) Effective span/250 or 7.6 mm, and
2) 30 mm ( SCI recommended absolute maximum value )
Deflection due to imposed loads = 0.2 mm (based on average inertia)
Additional deflection due to superimposed dead loads = 0.0 mm (based on average inertia)
Total deflection = 0.2 + 0.0
= 0.2 mm ( < 7.6 mm ) SATISFACTORY
DYNAMIC SENSITIVITY :
*** NOTE: loads are dead + super-imposed dead + 10% imposed
Dynamic inertia (cracked section) = 2077 cm4
Maximum deflection = 0.013 * 5.09 * (1.89* 1000 )^4 / (205*20769060 )/1000
= 0.20 mm
Frequency = 18 / 0.20 )
= 40.13 Hz ( > 5.00 Hz) SATISFACTORY

File Name: v9.0.22.0

Вам также может понравиться