Академический Документы
Профессиональный Документы
Культура Документы
FULL OUTPUT
COMPOSITE:
Inertia, Ixx - Uncracked 3624 cm4/m Cracked 1835 cm4/m
Self weight of concrete slab (wet) 3.43 kN/m Self weight of decking 0.13 kN/m
FIRE DATA :
Design method SIMPLE Fire resistance period 120 mins
CONSTRUCTION STAGE
LOADINGS Unfactored(kN/m) Factored(kN/m)
Self weight of decking 0.13 0.18
Self weight of concrete slab (wet) 3.43 4.81
Construction load (one span) 2.37 3.79
Construction load (adjacent span(s)) 0.79 1.26
Total factored load (maximum) = 0.18 + 4.81 + 0.00 + 3.79
= 8.78 kN/m
EFFECTIVE SPAN OF DECK :
Effective span Le, is the smaller of
1) c/c of supports = 1.90 m
2) clear span + deck depth = 1.75 + 46.0 / 1000
= 1.79 m
Therefore Le = 1.79 m
SHEAR RESISTANCE CHECK :
*** Check at first interior support position
Applied shear = [1.250 * 0.18 + 1.250 * 4.81 + 1.250 * 0.05 + 2.500 * 3.79/3] * 1.79 / 2
= 8.48 kN/m
Shear strength of decking, pv = 168.0 N/mm
Shear resistance, Pv = 79.7 kN/m
UNITY FACTOR = 0.11 PASS
WEB CRUSHING RESISTANCE CHECK :
*** Check at first interior support position
Applied reaction 16.96 kN/m
Web crushing resistance, Pw 68.99 kN/m
UNITY FACTOR = 0.25 PASS
BENDING RESISTANCE CHECK :
NOTE: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
SAGGING:
Max applied moment = [0.070 * 0.18 + 0.096 * 4.81 + 0.096 * 0.05 + 0.096 * 3.79] * 1.79^2
= 2.71 kNm/m
Moment resistance, Mc = 5.99 kNm/m
UNITY FACTOR = 0.45 PASS
HOGGING:
Max. applied moment = 2.13 kNm/m
Moment resistance, Mc = 6.23 kNm/m
UNITY FACTOR = 0.34 PASS
INTERACTION OF BENDING MOMENT AND SHEAR :
NOTE 1: *** Check at first interior support position
NOTE 2: *** a 30% redistribution of hogging moment is taken based on equilibrium of the continuous decking as the sagging moment
does not exceed the design resistance
Applied shear = 7.97 kN/m
Shear resistance, Pv = 79.68 kN/m
Applied moment = 2.13 kNm/m
Moment resistance, Mc = 6.23 kNm/m
UNITY FACTOR = [7.97/79.68]^2 + [2.13/6.23]^2
= 0.13 PASS
NORMAL STAGE