General Description
Series D1VL directional control valves are high-
A performance, 4-chamber, direct operated, lever
controlled, 3 or 4-way valves. They are available in 2 or
A B
Features
Spring return or detent styles available
Heavy duty handle design
Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Maximum Flow See Reference Data
Force Required
to Shift Lever 25 N (5.6 lbs)
Operator
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
15.5
8.9 (0.61)
85.5 Full Shift
(3.37) 15.5
(0.61)
150.6
38.6 (5.93)
(1.52)
50.0
46.0 (1.97)
(1.81) 23.8
See
Note (0.94)
149.5 23.0
(5.89) (0.91)
46.0
(1.81)
Note: 22.0 mm (0.87) from bottom of bolt hole counterbore to bottom of valve.
2502-A1.p65, dd
D 1V
Directional Basic Operator Spool Style Seal Variations Design
Control Valve Valve Type and Location Compound Series
NOTE:
A
Not required
when ordering.
General Description
Series D1VC, D1VD and D1VG directional control
A valves are high performance, 4-chamber, direct
operated, cam controlled, 3 or 4-way valves. They are
available in 2-position and conform to NFPAs D03,
CETOP 3 mounting patterns.
Features
Choice of 2 cam roller positions (D1VC and D1VD)
Two styles available (D1VC and D1VG)
Short stroke option
Specifications
Mounting Pattern NFPA D03, CETOP 3, NG 6
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Nominal Flow 32 LPM (8.5 GPM)
Maximum Flow See Reference Data
Force Required D1VC, D1VD: 107 N (24 lbs.)
to Shift D1VG: 36 N (8 lbs.)
Maximum
Cam Angle 30
Ordering Information
D 1V
Directional Basic Actuator Spool Style Seal Variations Design
Control Valve Valve Compound Series
NOTE:
Not required
NFPA D03 Code Symbol Code Description when ordering.
CETOP 3 A B N Nitrile
1 V Fluorocarbon
P T
A B
Code Description
2
P T
Omit Standard
A B P05 Short Stroke
4 P10* Monitor Switch
Code Description
P T * Not CE or CSA approved.
C Cam (90 to A B
mounting surface)
8* Code Description Symbol
D Cam parallel to
P T
mounting surface Two position, A B
G Cam Lever
A B B spring offset operator
9 at A port end. P T
P T Two position, A B
A B H spring offset operator
81 at B port end. P T
Valve Weight: Type C & D 1.44 kg (3.2 lbs.) P T
Type G 1.6 kg (3.7 lbs.) Valve schematic symbols are per NFPA/ANSI
A B
Standard Bolt Kit: BK209 124x1.25 standards, providing flow P to A when energized.
82
Note flow paths reverse sides for #8 and #9
Metric Bolt Kit: BKM209 M50.8x30mm P T spools.
* 8 spool has closed crossover.
9 spool has open crossover.
38.5 38.4
Over-Travel (1.51)
(1.52) Full Spool Travel
Pre-Travel
Over-Travel
Full Spool Travel
Pre-Travel 38.5
(1.52)
38.5
(1.52)
79.1
(3.11)
52.0
(2.05)
See 23.8
Note (0.94)
General Description
Series D3L directional control valves are
A high performance, 4-chamber, direct operated, lever
controlled 3 or 4-way valves. They are available in
A B
Features
Spring return or detent styles available.
High flow, low pressure drop design.
Heavy duty handle design.
Specifications
Mounting Pattern NFPA D05, CETOP 5, NG 10
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Maximum Flow See Spool Reference Chart
Force Required
to Shift Lever 173 N (39 lbs.)
Operator
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
8.9
149.07 15.50
Full Shift
(5.873) (0.611)
162.81
(6.415)
89.95
(3.544)
58.23
(2.294) See 36.0
Note (1.418)
174.45 35.00
(6.873) (1.379) 70.00
(2.758)
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
2502-A2.p65, dd
D 3
Directional Basic Valve Operator Spool Style Seal Variations Design
Control Valve Type & Location Compound Series
NOTE:
A
Not required
NFPA D05 when ordering.
CETOP 5
NG10
Code Description
Omit Standard
I7* Monitor Switch
Operator Location (A or B End)
Code Operator Type For Valve Style * Not available on C, D or N
B C D E H K N styles.
Code Description Not CE or CSA approved.
L Lever (Standard) B B B A B B B N Nitrile
LB Lever (Alternate) A A A N/A A N/A A V Fluorocarbon
General Description
Series D3C and D3D directional control valves are
high performance, 4-chamber, direct operated, cam
controlled, 3 or 4-way valves. They are available in
A
2-position and conform to NFPAs D05, CETOP 5
mounting patterns.
Features
Choice of 2 cam roller positions (D3C and D3D).
Short stroke option.
High flow, low pressure drop design.
Specifications
Mounting Pattern NFPA D05, CETOP 5, NG 10
Maximum Operating: 345 Bar (5000 PSI)
Pressure Tank Line: 34 Bar (500 PSI)
Maximum Flow See Spool Reference Chart
Force Required 107 N (24 lbs.)
to Shift
Maximum 30
Cam Angle
Ordering Information
D 3
Directional Basic Valve Actuator Spool Style Seal Variations Design
Control Valve Compound Series
NOTE:
Not required
when ordering.
NFPA D05
CETOP 5
NG 10 Code Description Code Description
N Nitrile Omit Standard
V Fluorocarbon B5 Short Stroke
Code Description
C Cam (90 to
mounting surface)
Cam parallel to
D
mounting surface Code Description Symbol
Two position, A B
Dimensions
Inch equivalents for millimeter dimensions are shown in (**)
Cam Operated
Full
Valve Type Pre-Travel Spool Over-Travel
Travel
Standard 1.75 5.75 2.03
Valve (0.07) (0.23) (0.08)
70.0 B5 0 4.00 2.03
(2.76) Short Stroke (0) (0.16) (0.08)
12.0
35.0 (0.47)
(1.38)
Over-Travel
Full Spool Travel
Pre-Travel
89.95
87.3 (3.544)
(3.44)
36.0 36.00 See
See
(1.42) Note (1.418) Note
Note: 30.0mm (1.18") from bottom of bolt hole counterbore to bottom of valve.
2502-A2.p65, dd
General Description
Series D31*L directional control valves are 5-chamber,
A pilot operated, lever controlled valves. The valves are
suitable for manifold or subplate mounting.
Features
World design Available worldwide.
D31VL Pressure Drop Reference Chart -- Curve Number D31VL Pressure Drop vs. Flow
Spool Shifted Center Condition The chart to the left provides the flow vs. pressure drop
No. P-A P-B B-T A-T (P-T) (B-A) (A-B) (P-A) (P-B) (A-T) (B-T) curve reference for the D31VL Series valves by spool type.
1 3 3 2 1 - - - - - - -
2 3 3 1 1 3 3 3 4 4 1 1 Example:
4 3 3 1 1 - - - - - 1 1 Find the pressure drop at 76 LPM (20 GPM) for a D31VL
9 3 3 1 1 6 - - - - - - with a number 1 spool. To the right of spool number 1, locate
20 5 4 2 2 - - - - - - - the number 3 in the P-A column, and 2 in the B-T column.
30 4 3 1 1 - - - - - - -
Using the top graph, locate curves 2 and 3 and read the
pressure drop values. Total pressure drop through the valve
is the sum of the two values.
2502-A3.p65, dd
Ordering Information
D L
Directional Basic Valve Lever Operated Spool Style Pilot Supply Seal Variations Design A
Control Valve Pilot and Drain Compound Series
NOTE:
Code Description Code Description Not required
Lever Operated
when ordering.
31D NFPA D05HE, Pilot 1 Int. pilot/Ext. drain
CETOP 5H (ISO) Code Description
2 Ext. pilot/Ext. drain
Code Symbol Omit Standard
31V NFPA D05H, A B 4# Int. pilot/Int. drain
CETOP 5 7 Pilot choke meter out
1 5 Ext. pilot/Int. drain
P T 60 Pilot choke meter in
A B # Not available with
2, 8 & 9 spools.
Code Description 8 Stroke adj. 'B'
Valve schematic symbols
2 N Nitrile
are per NFPA/ANSI P T 9 Stroke adj. 'A'
standards, providing flow A B V Fluorocarbon
89 Stroke adj. 'A' & 'B'
P to A when energizing 4
operator A. Note P T
Code Description Symbol
operators reverse sides A B
A B
for #8 and #9 spool. See 8** & 9* B Sgl. operator, 2 position, spring offset.
installation information P T P to A and B to T in offset position. P T
A B
for details. A B
Dimensions Lever Operated Inch equivalents for millimeter dimensions are shown in (**)
46.0
(1.81)
89.2
(3.51)
59.7
(2.35)
233.4
(9.19)
General Description
Series D61VL directional control valves are
A 5-chamber, lever operated valves. They are available in
2 and 3-position styles. They are manifold or subplate
mounted valves, which conform to NFPA's D08,
CETOP 8 mounting patterns.
Specifications
Mounting Pattern NFPA D08, CETOP 8
NG25
Maximum 207 Bar (3000 PSI)
Operating T Port (tank):
Pressure 34 Bar (500 PSI)
With External Drain:
207 Bar (3000 PSI)
Maximum Flow See Reference Data
Pilot Oil Min: 6.9 Bar (100 PSI)
Pressure Oil Max: 207 Bar (3000 PSI)
Maximum Drain 34 Bar (500 PSI)
Pressure
Varies with pilot line size and
Response Time length, pilot pressure, pilot valve Features
shift time & flow capacity (GPM) Low force required to shift spool.
Hardened spools provide long life.
Ordering Information Low pressure drop design.
D 61V L
Directional Basic Lever Operated Spool Style Pilot Supply Seal Variations Design
Control Valve Pilot and Drain Compound Series
Valve NOTE:
NFPA D08 Lever Operated Code Description Code Description Code Description Not
Pilot 1 Int. pilot/Ext. drain Omit Standard required
CETOP8 N Nitrile
when
2 Ext. pilot/Ext. drain V Fluorocarbon 7 Pilot choke
meter out ordering.
Code Symbol Code Symbol 4# Int. pilot/Int. drain
60 Pilot choke
5 Ext. pilot/Int. drain
A B A B meter in
1 8* # Not available with 2, 8 & 9 spools.
9** 8 Stroke adj. 'B'
P T P
A
T
B
9 Stroke adj. 'A'
A B
reverse sides for #8 and #9 spools. See E Single operator, 2 position, spring centered.
installation information for details. P to B and A to T in shifted position. P T
A B
H* Single operator, 2 position, spring offset.
Valve Weight: 12.1 kg (26.7 lbs.) P to B and A to T in offset position. P T
A B
Standard Bolt Kit: BK227 K Single operator, 2 position. Spring centered. This condition
P to A and B to T in shifted position. varies with
Metric Bolt Kit: BKM227 P T
spool code.
*Available with 001, 002, 004, 011, 012.
64.5
(2.54)
23.0
149.1 (0.91)
(5.87) 8.9
Full Shift
59.6
(2.35)
258.8
(10.19)
132.3
(5.21)
108.5
(4.27)
See
Note
2502-A4.p65, dd
General Description
Series D81VL directional control valves are
A 5-chamber, lever operated valves. They are available in
2 or 3-position styles. These valves are manifold or
subplate mounted, and conform to NFPA's D08,
CETOP 8 mounting pattern.
Specifications
Mounting Pattern NFPA D08, CETOP 8, NG25
Maximum 350 Bar (5000 PSI)
Operating T Port (tank): 34 Bar (500 PSI)
Pressure With External Drain: 350 Bar (5000 PSI)
Maximum Flow See Reference Data Charts
Pilot Oil Min: 6.9 Bar (100 PSI)
Pressure Oil Max: 350 Bar (5000 PSI)
Maximum Drain 34 Bar (500 PSI)
Pressure
Response Time Varies with pilot line size and length,
pilot pressure, pilot valve shift time & Features
flow capacity (GPM) Low force required to shift spool.
Hardened spools provide long life.
Ordering Information Low pressure drop design.
D 81V L
Directional Basic Valve Lever Operated Spool Style Pilot Supply Seal Variations Design
Control Valve Pilot and Drain Compound Series
NOTE:
Code Description Code Description Not
NFPA D08 Lever Operated
N Nitrile Omit Standard required
CETOP 8 Pilot when
V Fluorocarbon 7 Pilot choke
ordering.
meter out
Code Symbol Code Symbol Code Description
60 Pilot choke
1 Int. pilot/Ext. drain
A B A B
meter in
1 11 2 Ext. pilot/Ext. drain
8 Stroke adj. 'B'
P T P T 4# Int. pilot/Int. drain
A B A B
5 Ext. pilot/Int. drain 9 Stroke adj. 'A'
2 12 89 Stroke Adj. 'A' & 'B'
P T
# Not available with 2, 8, 9 & 30 spools.
P T
A B A B
spool. See installation information for details. H Sgl. operator, 2 position, spring offset. P to B
and A to T in offset position. P T
A B This
Valve Weight: 19.6 kg (43.2 lbs.) K Sgl. operator, 2 position. Spring centered. condition
P to A and B to T in shifted position. varies with
Standard Bolt Kit: BK228 P T
spool code.
Metric Bolt Kit: BKM228 Available with 20 & 30 spools only.
Bold: Designates Tier I products and options.
Non-Bold: Designates Tier II products and options. These products will have longer lead times.
2502-A5.p65, dd
Lever Operated
A
M6 x 1 Plug for
Variations 1, 2 & 3
Torque to:
1.78 0.22 Nm
(16 2 in-lbs)
Do Not Loctite
277.8
(10.94)
151.3
(5.96)
127.5
(5.02)
57.0 47.1
(2.24) (1.85)
58.0
153.1 153.1 (2.28)
(6.03) (6.03) 116.0
(4.57)
116.5
(4.59)
Note: 57mm (2.24") from bottom of bolt hole counterbore to bottom of valve.
2502-A5.p65, dd
General Description
Series D101VL directional control valves are
A 5-chamber, lever operated valves. They are available
is 2 or 3-position styles. These valves are manifold or
subplate mounted, and conform to NFPA's D10,
CETOP 10 mounting pattern.
Specifications
Mounting Pattern NFPA D10, CETOP 10
NG32
Maximum 207 Bar (3000 PSI)
Operating T Port (tank): 34 Bar (500 PSI)
Pressure With External Drain:
207 Bar (3000 PSI)
Maximum Flow See Reference Chart
Pilot Oil Min: 6.9 Bar (100 PSI)
Pressure Oil Max: 207 Bar (3000 PSI)
Maximum Drain 34 Bar (500 PSI)
Pressure
Response Time Varies with pilot line size and
length, pilot pressure, pilot valve Features
shift time & flow capacity (GPM) Low force required to shift spool.
Hardened spools provide long life.
D 101V L
Directional Basic Valve Lever Operated Spool Style Pilot Supply Seal Variations Design
Control Valve Pilot and Drain Compound Series
NOTE:
NFPA D10 Code Type Code Description Not
Lever Operated
CETOP 10 N Nitrile Omit Standard required
Pilot
when
V Fluorocarbon 7 Pilot choke
ordering.
Code Symbol meter out
A B
Code Supply Drain 60 Pilot choke
1 1 Int. pilot/Ext. drain meter in
P
A
T
B
2 Ext. pilot/Ext. drain 8 Stroke adj. 'B'
2 4# Int. pilot/Int. drain 9 Stroke adj. 'A'
P T 5 Ext. pilot/Int. drain 89 Stroke adj. 'A' & 'B'
A B
Bold: Designates Tier I products and options. Valve Weight: 35.0 kg (77.2 lbs.)
Standard Bolt Kit: BK229
Non-Bold: Designates Tier II products and options.
Metric Bolt Kit: BKM229
These products will have longer lead times.
2502-A6.p65, dd
Lever Operated
A
Section A-A
59.8 89.2
(2.36) (3.51) 8.9
Full Shift
309.2
(12.17)
182.6
(7.19)
29.3
158.8 (1.15)
(6.25)
36.8 73.2
(2.88) 18.8
(1.45) (0.74)
175.5 175.5 196.1
(6.91) (6.91) (7.72)
199.1
(7.84)
Note: 36.83mm (1.45") from bottom of bolt hole counterbore to bottom of valve.