DESIGN OF REINFORCEMENT PAD AS PER ASME B31.

8
HEADER
Enter Data here
Header Pipe Thickness-H
Pressure-P
Joint Eiiciency-E
Design factor-F
Mother pipe OD -D
Corrosion Allowence - c
TEMPERATURE DERATING FACTOR-T
Thining Allowance
Allowable Stress-S
THICKNESS WITHOUT THINNING ALLOWANCE
SLEEVE THICKNESS t
Branch Pipe
Enter Data here
Branch PipeThickness - B
Branch pipe OD - d
Corrosion Allowence
Allowable Stress-S1
THICKNESS WITHOUT THINNING ALLOWANCE
BRANCH THICKNESS THICKNESS tb
REINFORCEMENT CALCULATION
HOT TAPPING DIAMETER / INSIDE DIAMETER OF THE BRANCH d
Excess Thickness in Header Wall H-t-c
Excess Thickness in Branch Pipe Wall B-tb-c
REQUIRED REINFORCEMENT Ar = dt
REINFORCEMENT PROVIDED BY HEADER A1= (H-t-c)*d
EFFECTIVE AREA IN BRANCH A2 = 2*(B-tb-c)*L
Effective area In Branch must be multiplied by S1 /S (para 831.4.1 (f)) A2'

Reinforcement Pad Thickness M


OD OF REINFORCEMENT PAD
Reinforcement Height - L, Lesser of 2.5 *B +M (pad thickness ) and L= 2.5*H
i. 2.5 *B +M (pad thickness )
ii. 2.5 * H
Effective Area in PAD - A = ( OD OF PAD -OD OF BRANCH PIPE)* PAD THICKNESS
FILLET WELD SIZE - a
EFFECTIVE AREA OF FILLET WELD A4 =0.5*( a*a)*4
AREA AVAILABLE FOR REINFORCEMENT A3= A1+A2'+A4+A

DESIGN IS SAFE
ASME B31.8

INPUT
19.1 mm OUTPUT
92 kg/cm2 REQUIRED
1
0.72
610 mm
1.5 mm
1
0
1617 kg/cm2
24.095 mm
25.595 mm

32 mm
660.2 mm
1.5 mm
1617 kg/cm2
26.0779 mm
27.6 mm

584.2 mm
-8.0 mm
2.9 mm 44
14952.599 mm^2
-4670.679 mm ^2
279.0606 mm ^2
279.0606 mm ^2

32 mm
1320.4 mm
47.75 mm
112 mm
47.75 mm
21126.4 mm ^2
27.6 mm
1521.0811 mm ^2
18255.863 mm ^2
Description Design of 24x12"x 600# Stopple Tee PLANT-TECH
Client GAIL, VIJAIPUR POWER
PPTS-HT-24X 600#000
Drawing Number
PPTS-HT-24X 600#005
Issue Date 21/10/2016
Revision 0

Вам также может понравиться