Вы находитесь на странице: 1из 3

Feature Mini Poster ODUk SNCP

What? Benefits?
ODUk SNCP supports flexible application
ODUk SNCP is a type of protection that provides subnetwork connection scenarios and can protect all or some services
protection (SNCP) for services at the optical channel data unit - k (ODUk) level on ODUk trails.
on the OTN network.

A B C D E F

ODUk SNCP Protection


ODUk path
How? Signal flow

Tributary boards and line boards are used together to implement dual-
feeding and selective receiving of services, achieving ODUk SNCP for the Scenario?
services. ODUk SNCP is classified into three sub-types of
protection. Different monitoring methods are used in
the sub-types of protection to provide ODUk SNCP for
services in various scenarios.
SNC/I (Inherent):
Uses SM overheads for monitoring.
Applies to subnets without electrical REG
sites.
No limit is set on the type of services
received by tributary boards
SNC/N (Non-intrusive):
Uses PM or TCM overheads for monitoring.
Applies to sites that contain any sites and do
not have cascading protection.
No limit is set on the type of services
received by tributary boards
SNC/S (Sub-layer):
Uses TCM overheads for monitoring.
Applies to sites that contain any sites and
have cascading protection.
Tributary boards receive OTN services.
Prepared by Fixed Network Solutions Dept. Page 1
Feature Mini Poster ODUk SNCP

SNC/I? SNC/N?
Connections may be indirectly monitored by using the data that The connection may be directly monitored by use of listen-only
is inherently available from the server-layer network. (non-intrusive) monitoring of the original characteristic
Protect service against defects detected at the ODUk link connection. No
information.
defect detection is performed at the ODUk layer itself.

Protect service against defects detected at the ODUkP layer or ODUkT sub-
N Subnetwork N layers at the tail end of the protection group.
(without electrical T
1 1
regeneration site)
Any client
T Or service N Subnetwork N
T
Subnetwork 1 (Any site type) 1
Any client
N (without electrical N Any client
service N
2 regeneration site) 2 T Or service
Site A Site B Any client
N Subnetwork N
service (Any site type) N
Working signals flow Protection signals flow 2 2

Site A Site B

Working signals flow Protection signals flow

SNC/S?
Some portion of the original trail's capacity is over-written such that
When the SNCP type is SNC/N for the TCM
the part of the connection that is of interest can be directly monitored
layer or SNC/S, to ensure that a TCM alarm can
by a trail created in a sub-layer. trigger ODUk SNCP protection switching, the
Protect service against defects detected at the ODUkT sub-layer trail (TCM).
Switching is triggered only on defects of the protected domain. TCM overheads of the source and sink boards
TCM1 TCM2 need to be configured.
Protected domain Protected domain

N N N Subnetwork N
Subnetwork
1
(Any site type) 3 5 (Any site type) 7
T
When the SNCP type is SNC/N for the PM layer
OTN
T Or service or SNC/I, no overheads need to be configured.
OTN Subnetwork Subnetwork
service N
2
(Any site type) N
4
N
6
(Any site type) N
8
N For details about the method for configuring
Input ODUk
defects will not Input ODUk
overheads, see Configuring the TCM Overheads
trigger switching
Site A Site B Site C
defects will not
trigger switching for ODUk SNCP Protection Switching under
Working signals flow between A and B Protection signals flow between A and B OTN Overhead in the Product Documentation.
Working signals flow between B and C Protection signals flow between B and C

Prepared by Fixed Network Solutions Dept. Page 2


Feature Mini Poster ODUk SNCP

Specifications? Limitations?
ODUk SNCP has the following restrictions:
Item Specifications
The OptiX OSN product supports a maximum of 512 SNCP
protection groups when it uses the TN51SCC board. To support
Granularity ODUk (k = 0, 1, 2, 3, 4, flex) more than 512 SNCP protection groups, the OptiX OSN product
must use the TN52SCC board.
Board offline events (either the board is
Trigger removed or undergoes a cold reset), signal Any of the three boards in the service selective receiving
conditions failure (SF) events, signal degrade (SD) direction of an ODUk SNCP protection group can be a tributary or
events line board. The boards on the working and protection channels,
however, support only OTUk services at the same ODUk level.
Switching
Single-ended switching
type

Switching
50 ms (excluding the detection time)
time
Reference?

For more details about ODUk SNCP, see the corresponding


Standard? document at http://support.huawei.com. The navigation path is
as follows: "Description""Feature Description" "ODUk
The ODUk SNCP complies with the following standards or SNCP"
protocols: Trigger Conditions
G.798 (Characteristics of optical transport network hierarchy Specifications
equipment functional blocks) Feature Updates
G.873.1 (Optical Transport Network (OTN): Linear protection)
Dependencies and Limitations
G.808.1 (Generic protection switching Linear trail and
Configuration-Related Information
subnetwork protection)

Prepared by Fixed Network Solutions Dept. Page 3