Вы находитесь на странице: 1из 2

ReciprocatingCompressorPower.

xls
Description: This spreadsheet calculates stage power of reciprocating compressor.

Instruction: 1) Update parameter valves in the Input Data; 2) Click "Solution" button; 3) View
result in the Solution section.

Input Data:
Gas flow rate (qg): 32 MMscf/day Tpc=169.0+314.0*SGF
Stage inlet temperature (T1): 70 F
o
Ppc=708.75-57.5*SGF
Stage inlet pressure (p1): 200 psia Tpr=(T+460.0)/Tpc
Gas specific gravity (gg): 0.65 air=1 t=1/Tpr
Stage outlet pressure (p2): 600 psia Ppr=p/Ppc
Gas specific heat ratio (k): 1.25
Overall efficiency (Eo): 0.8 A=0.06125*t*EXP(-1.2
Base temperature (Tb): 60 F
o
B=t*(14.76-9.76*t+4.58
Base pressure (pb): 14.7 psia C=t*(90.7-242.2*t+42.
D=2.18+2.82*t

F=-A*Ppr+(Y+Y*Y+Y**
z = Hall-Yarborogh Method = 0.9653

p2
r= = 3.0000
p1

[( ) ]
Z 1( k 1 )/k
k 3 . 027 pb p2
Hp MM = T1 1 = 53.58 hp
k1 T b p1

q MM Hp MM
Hp b = = 2143.02 hp
Eo
z1 ( k1)/k
p
T 2=T 1 2
p1 ( ) = 195.22 F
o

T 1 +T 2
T avg = = 132.61 F
o

2
Cp = 9.43 Btu/lbm-moloF
3
Cooler load=2 .64010 q MM C p ( T avg T 1 ) = 49,857,010 Btu/day
Don't change data in red!
Tpc=169.0+314.0*SGFG = 373.1 R
o

Ppc=708.75-57.5*SGFG = 671.245 psia


Tpr=(T+460.0)/Tpc = 1.4205
t=1/Tpr = 0.7040
Ppr=p/Ppc = 0.2980

A=0.06125*t*EXP(-1.2*(1.-t**2) = 0.0388
B=t*(14.76-9.76*t+4.58*t*t) = 7.1516
C=t*(90.7-242.2*t+42.4*t*t) = -41.38
D=2.18+2.82*t = 4.1652

= 0.0120
Y=
F=-A*Ppr+(Y+Y*Y+Y**3-Y**4)/(1.-Y)**3-B*Y*Y+C*Y**D
-1.91720796055402E-05