Contents

AS-i 877

Bar Code Readers 892

Communication Adaptor 888

Data Acquisition Cards 883

Embedded Control Systems 890

Fieldbus 874

Idec PLCs 870

IMO PLCs 866

Industrial Computers 882

Industrial Monitors 883

Input/Output Modules 881

Logic Controllers 854

Mitsubishi PLCs FX Series 855

Omron PLC's 865

Operator Interfaces (HMIs) 871

PC/104 Embedded PC 888

Siemens PLCs 862

Smart Card Readers 891

Swipe Card Readers 897

Tachometer/Trip Boards 882

Telemecanique/Modicon PLCs 863

Industrial Computing & PLCs 26


Industrial Computing & PLC's
Logic Controllers LOGO! Soft SIEMENS
LOGO! Logic Module

LOGO! Short H=90, W=72, D=55


LOGO! Long and LOGO! Bus H=90, W=126, D=55 LOGO! Soft
LOGO! is a compact and intelligent logic module which is designed to perform many of Optional Windows based software package
the roles currently performed by relays, timers, contactors or counters. LOGO! is an Enables convenient creation, testing, simulation modification, archiving and
"All in One" package: display, operator panel and, included in its many other functions, printing of LOGO! control diagrams
as many as 16 timers integrated into one module. It is compact, easy to operate, cost LOGO! Soft Comfort
effective and can be used for any task without additional accessories. Up to 19 differ-
ent functions can be used in LOGO! accessed with the touch of a button. Wiring over- Create control programs more efficiently with greater reliability
heads are kept to a minimum and future changes can be quickly responded to. Programs created using drag and drop on the PC
Off-line program simulation
Features include: Status display for several functions simultaneously
Choice of supply voltage: 12Vdc, 24Vac/dc or 115/230Vac CD-ROM based
PLC192
Transistor or relay outputs (max.10A output)
AS-interface option Price Each
Program modules for copying, back-up or know how protection Mftrs. List No. Order Code 1+ 5+ 10+ 25+
Basic logic functions
LOGO! Soft 6EDI 058-OAAOO-OBAI 309-6440 180.00 167.13 167.13 161.37
ON/OFF delay, pulse generator, up/down counter and weekly and annual clock
LOGO!
Specification: Soft Comfort 6EDI 058-OBAOO-OYCO 309-6452 117.00 112.68 108.63 105.63
Mounting Display Keypad Protection Operating Temp PC cable 6EDI 057-IAAOO-OBAP 309-6464 147.00 141.12 135.69 130.68
Din rail/distribution board 4 lines 10 characters 6 keys IP20 0 to 55C

Voltage Output Clock Mftrs. List No. Order Code


LOGO! Short - 6 inputs, 4 outputs LOGO! Accessories
12Vdc 10A max. 6EDI-052-IBBOO-OBAI 309-6312
24Vdc 0.3A - 6EDI-052-ICAOO-OBAI 309-6324
24Vac/dc 10A max. 6EDI-052-IHBOO-OBAI 309-6336
115/230Vac 10A max. 6EDI-052-IFBOO-OBAI 309-6348
LOGO! Long - 12 inputs, 8 outputs
12Vdc 10A max. 6EDI-053-IBBOO-OBAI 309-6350
24Vdc 0.3A - 6EDI-053-ICAOO-OBAI 309-6361
24Vdc 10A max. 6EDI-053-IHHOO-OBAI 309-6373
115/230Vac 10A max. 6EDI-053-IFBOO-OBAI 309-6385
LOGO! Bus - 12 standard + 4 AS-i inputs, 8 standard + 4 AS-i outputs Optional EEPROM memory modules may be used to back-up programs
24Vdc 10A max. 6EDI-053-IHHOO-OBAI 309-6397 Red module includes know how protection
26 115/230Vac 10A max. 6EDI-053-IFHOO-OBAI 309-6403

know how prevents unauthorized viewing or modification of the program
Manual provides further information on LOGO! uses and applications
FOR SUITABLE POWER SUPPLIES, SEE ORDER CODES 184-202 OR 184-214,
Mounting bracket allows front panel mounting of the LOGO! short module
Section 4.16
Panel window dimensions: H=45, W=81
Industrial Computing & PLC's 854

PLC187

Price Each PLC195

Voltage Outputs Order Code 1+ 5+ 10+ 25+ Price Each


LOGO! Short Memory Module Mftrs. List No. Order Code 1+ 5+ 10+ 25+
12Vdc Rel. 309-6312 264.00 254.22 245.13 238.32 Blue 6EDI 056-IBOO-OAAO 309-6415 42.00 40.44 39.00 37.92
24Vdc Trans. 309-6324 252.00 242.67 234.00 227.49 Red 6EDI 056-4BAOO-OAAO 309-6427 48.00 46.23 44.58 43.32
24Vac/dc Rel. 309-6336 264.00 254.22 245.13 238.32 Manual 6EDI 050-IAAOO-OBE2 309-6439 33.00 31.77 30.63 29.79
115/230Vac Rel. 309-6348 264.00 254.22 245.13 238.32 Mounting Bracket 7LF9-003 309-6476 22.46 21.61 20.87 20.28
LOGO! Long
12Vdc Rel. 309-6350 417.00 401.55 387.21 376.47
24Vdc Trans. 309-6361 387.00 372.66 359.37 349.38 LOGO! Starter box
24Vdc Rel. 309-6373 417.00 401.55 387.21 376.47
115/230Vac Rel. 309-6385 417.00 401.55 387.21 376.47
LOGO! Bus
24Vdc Rel. 309-6397 573.00 551.79 532.08 517.29
115/230Vac Rel. 309-6403 579.00 557.55 537.63 522.72

LOGO! Contact
Enables loads up to 20A and motors up to
44W to be switched directly
24Vdc or 230Vac switching voltages available
Useful for noise-sensitive areas such as hospi-
tals or domestic environments

H=72, W=36, D=59


PLC193

Price Each
Voltage Mftrs. List No. Order Code 1+ 5+ 10+ 25+ Ideal for the new user, the starterbox contains everything you need to get started using
LOGO! for the first time
24Vdc 6EDI 057-4CAOO-OAAO 309-6490 51.00 49.11 47.37 46.05
230Vac 6EDI 057-4EAOO-OAAO 309-6506 42.00 40.44 39.00 37.92 Low cost option for getting started
Comes in an attractive toolbox style case
Starterbox contains: LOGO! Short, 115/230Vac LOGO! Manual
PC programming cable Tips and Tricks CD-ROMl
LOGO! Soft

854 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
PLC197
Mitsubishi PLCs
Price Each
Order Code 1+ 5+ 10+ FXON-Micro
Base Units
LOGO! Starterbox 309-6488

Intelligent Relays
Easy
Intelligent - all-round product for
switching and control
Uses keystrokes to make classic wiring
diagrams
Clear function layout
20 standard functions conbined in one
unit Incorporates all the powerful features of the FXO, with expansion capability
Menu driven Programming can be achieved by using GPP/WIN software (329-9963) and Hand-
Password function to enable selective held programmer (276-315)
access Standard Features include: I/O bus connection for extending upto
Five language menu: English, French, High speed, 3.6s per logic instruction 128 I/O
Dimensions German, Italian and Spanish 2000 step EEPROM memory Advance Features include:
71.5 90 53
Built-in RUN/STOP switch 4 built-in combined 5kHz high speed
Functions Include 2 built-in analogue adjustment poten- counters (configurable 2 off AB phase
8 timers, each 0 to 100hrs, (each is multifunction) tiometers bi-direction)
4 Real Time clocks (on RC versions) Built-in 24Vdc supply (200mA) Analogue extension capability
8 up/down counters 64 timers (100ms, 10ms, 1ms unit RS232C user-defined communications
8 Inputs/4 outputs (2 inputs can be used as analogue on DC versions) versions) interface option
8 impulse relays 48 standard counters (latched, Real-time clock cassette option
8 Comparators unlatched) Scan independent high speed outputs
16 Internal relays 256 data registers (further 128 latched) Step ladder sequence for data table
32 bit arithmetic (10 digit numbers) manipulation
EASY 412-AC-R 115-230V AC
EASY412-AC-RC 115-230V AC with Real Time Clock
EASY 412-DC-R 24V DC Supply voltage 100 to 200Vac +10% - 15% or 24Vdc +10% - 15%
EASY 412-DC-RC 24V DC with Real Time Clock Supply for sensors 24Vdc, 100mA (ac version only)
EASYSOFT (Software) Software Package Inputs 24Vdc, 7mA opto-isolated (sink/source configurable)
EASY PC CABLE (2M) 2M cable for connection to PC Outputs Volt free relays, rated 2A@250Vac or 30Vdc
CTL338
External Dimensions
Price Each Description H W D Mftrs. List No. Order Code
Mftrs List No. Order Code 1+ 5+ 10+ 14 in, 10 out, ac powered 90 135 87 FXON-24MR-ES 774-420
24 in, 16 out, ac powered 90 150 87 FXON-40MR-ES 774-431
EASY 412-AC-R 222-203 36 in, 24 out, ac powered 90 185 87 FXON-60MR-ES 774-443
EASY 412-AC-RC 222-215 16 in, 8 out, dc powered 90 135 87 FXON-24MR-DS 774-455
EASY 412-DC-R
EASY 412-DC-RC
EASYSOFT (Software)
222-185
222-197
222-227
24 in, 16 out, dc powered
36 in, 24 out, dc powered
90
90
150
185
87
87
FXON-40MR-DS
FXON-60MR-DS
774-467
774-479 26
EASY PC CABLE (2M) 222-240
FOR SUITABLE PROGRAMMER SEE ORDER CODE 329-8863 PAGE 860

Industrial Computing & PLC's 855


Programming Manual 320-3475 PLC144X
Programming Guide 320-3487
Price Each
Order Code 1+ 2+ 5+ 10+ 20+
Alpha Logic Controllers AC Supply
24 I/O 774-420
The series controller is a powerful, low cost controller designed to provide simple
40 I/O 774-431
supervisory control around the factory, home, office etc. Features included in the
60 I/O 774-443
include Real Time Clock, High Current Switching Relays, Analogue Inputs and 100
Hours Memory Backup. The main feature, however, is the ease of use of the software. DC Supply
The Windows based package makes it the easiest way to program a controller for any 24 I/O 774-455
level user. 40 I/O 774-467
60 I/O 774-479
Features Include: Cable to connect to PC or modem for
Alpha-numeric display 4 lines of 10 loading/downloading cables
characters Function block programming software
All program functions adjustable via 64 functions Extension Unit
the front panel On-line monitoring
20 I/O units can be used as slaves in Programming wizards
AS-I networks
EEPROM to store alternative programs
or data
INC264

Supply Order Price Each


Voltage I/O Mftrs. List No. Code 1+ 5+ 10+
Controllers
100-240V ac 4 In/2 Out AL-6MR-A 312-4745
100-240V ac 6 In/4 Out AL-10MR-A 314-2814 H=90, W=150, D=87
24V dc 6 In/4 Out AL-10MR-D 314-2826
100-240V ac 12 In/8 Out AL-20MR-A 329-8840 Increases I/O capacity of base unit. Connected by ribbon cable (supplied)
24V dc 12 In/8 Out AL-20MR-A 329-8851 Also provides 24Vdc supply for further expansion blocks
Accessories Extension cable is used for connecting extension unit to base unit
Cable AL-232CAB 314-2838 Supply voltage 100-240Vac, 50-60Hz Number of inputs 24
EEPROM AL-EEPROM 312-4757 Inputs 24Vdc (sink/source configurable) Number of outputs 16
Software ALVLS 314-2840 Outputs Voltage free relays, rated 2A @ 240Vac or 30Vdc
PLC143X

Order Price Each


Type Mftrs. List No. Code 1+ 2+ 5+ 10+ 20+
40I/0 FXON-40ER-ES 774-480
Ext. Cable FXON-65EC 774-560

continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 855
Industrial Computing & PLC's
Mitsubishi PLCs continued Real-Time Clock Cassette
Extension Blocks
Can be 774-558
added to base unit or extension unit to
increase capacity
Supply voltage 24Vdc +10% - 15%

774-546

Plugs directly into a cassette port of any FXON base unit


With full calendar year, month, day and time control
Requires optional battery to retain clock function during power-off
PLC139X

Input Output External Dimensions Order Code Mftrs. Order Price Each
8 sink/source H=90, W=43, D=87 774-492
8 relay H=90, W=43, D=87 774-509
List No. Code 1+ 2+ 5+ 10+ 20+
8 transistor H=90, W=43, D=87 774-510 Real-Time
PLC140X
Clock Cassettes FX-RTC 774-546
Price Each Real-Time
Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 20+ Clock Battery FXON-40B 774-558
FXON-8EX-ES 774-492
FXON-8EYR-ES 774-509
FXON-8EYT-ESS 774-510 The FX Family of Programmable Controllers
The FX Family of Programmable Controllers.
The FX Family of Programmable Controllers offer the user a wide range of applications
Analogue to Digital Converters from small low cost relay replacement, to sophisticated control of up to 256 I/O. The
Special Block family utilises common peripheral devices such as programmers, man machine inter-
faces (MMIs) and memory cassettes.
Has two input channels and one output Programming of the FX family is performed using either the MELSEC MEDOC menu
channel driven ladder/logic instruction set software package, or using one of the two hand held
Input channels receive an analogue sig- programmers available (FX-20P-E & FX-10P-E).
nal and convert it to a digital one
Output channel takes a digital valve and FXO
outputs on equivalent analogue signal Micro compact size
Stand alone programmable controller includes built in power supply, CPU and
Key Features: switch gear
Default Input/Output ranges 0-10Vdc Easy to configure and use
26 Current selection via terminal wiring
Offset and gain adjustable to give 0-5V,
Available in 3 different I/O sizes, 14, 20 & 30
High processing speed (3.5 s/basic instructions)
4-20mA 800 step battery free memory using an internal EEPROM
8 bit resolution
FXON
Industrial Computing & PLC's 856

Power requirement 24Vdc, 90mA


Conversion speed 3s Combines micro compact size with modularity
I/O points can be expanded
H=90, W=43, D=87 Facilitates specialist functions i.e. analogue control
PLC145X
High processing speed (3.5 s/basic instructions)
Mftrs. Order Price Each 2000 step battery free memory
List No. Code 1+ 2+ 5+ 10+ 20+ Integral run/stop switch
Two analogue potentiometers to manipulate data without dedicated programming
8 I/O FXON-3A 774-522 tools
Removable terminal blocks on larger I/O units
Optional EEPROM cassette available
RS232C User Defined Comms Interface Optional Real Time Clock cassette
Special Block Optional communication adapter
Connects to base unit for communication in FX
versatile user-defined protocols on the RS232C Compact size and modular structure
format Large I/O configurations from 16 points to 256
Ideal for data collection from/to computers, Modular structure giving greater flexibility
barcode readers, weighing machines etc. Up to 8 special function blocks can be used on each FX system
Enhanced programming set
Key Features High processing speed (0.47 s/basic instructions)
Simple base unit powered plug-in system 2000 step RAM memory for continuous re-writing
Parity, datalength, stop and start bit: user- Removable terminal blocks
defined Optional communication adapter
Baud rate: 300 - 19,200bps
inc186
Header, terminator: user-definable or none
Control line: hardware or none
Can be configured to initiate communications Main Processing Units
H=90, W=40, D=70
PLC142X

Price Each
Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 20+
FXON-232A DP 774-534

856 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Fast execution of basic instruction set ( 0.47s) Powered Extension Units - Digital
Floating point maths for better handling of decimal numbers I/O
PID control loop for precise and responsive control
6 high-speed counters up to 10KHz maximum
Built-in 2000 step program memory expandable to 8000 steps using additional
memory cassettes
FX units include a wide tolerance ac power supply which will operate within the
voltage range 85V ac to 264V ac
Wide range of additional I/O modules and special function modules available
Relay outputs can be used for both ac and dc applications
Standard programming functions include PID and floating point maths
The FX range of programmable controllers can be combined with a range of expansion
blocks and powered extension units, making them suitable for large and small
applications. The FX family of controllers are available with main processing units 24V dc service supply provided on each unit
ranging from 16 to 128 I/O points, all of which can be expanded up to a total of 256 Removable terminal blocks for ease of installation and maintenance
points I/O. Communications add on modules allow connection to modems, printers, Flexible installation position: adjacent or parallel installation using cables provided
bar code readers, thermocouples, analogue devices, etc. Optional DIN rail or direct mounting
Wide range ac power supply will accept 85 to 264V ac at 50 to 60Hz
The FX can be programmed in stepladder (STL) using either a computer-based soft-
ware, GPP/WIN or hand-held programmer, the FX-20P-E. The FX main processing unit can be expanded with additional I/O up to 256 points.
Small increases in I/O capacity are achieved using unpowered expansion blocks; how-
Total I/O O/P I/P Unit Size Weight Mftrs List No. Order Code ever, large scale increases in I/O require the FX range of powered extension units.
16 8 8 150 x 140 x 95 1.0 kg FX-16MR-ES 711-4552 Additional benefits of the powered extension units include the facility to add special
24 12 12 150 x 140 x 95 1.3 kg FX-24MR-ES 711-4564
32 16 16 160 x 140 x 95 1.5 kg FX-32MR-ES 711-4576
function blocks i.e. analogue and the use of an additional 24V dc service supply. The
48 24 24 230 x 140 x 95 2.0 kg FX-48MR-ES 711-4588 powered extension unit is connected to the FX main processing unit using either the
64 32 32 270 x 140 x 95 2.5 kg FX-64MR-ES 711-4590 55mm or 650mm cable supplied. This allows mounting of the powered extension unit
80 40 40 330 x 140 x 95 3.0 kg FX-80MR-ES 711-4606 adjacent to the FX main processing unit or in parallel.
128 64 64 410 x 140 x 95 4.0 kg FX-128MR-ES 711-4618
The I/O allocation on each unit is divided equally between Inputs and Outputs (I/O).
inc67 The input devices operate at 24V dc and can be configured to accept either Sink (NPN)
or Source (PNP) style wiring. The relay outputs provide users with the flexibility to
Price Each switch ac or dc outputs as required.
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-16MR-ES 711-4552 Total I/O Unit Size Weight Mftrs List No. Order Code
FX-24MR-ES 711-4564 32 160 x 140 x 95 1.5 kg FX-32ER-ES 711-4837
48 230 x 140 x 95 2.0 kg FX-48ER-ES 711-4849
FX-32MR-ES 711-4576 inc71
FX-48MR-ES 711-4588
FX-54MR-ES 711-4590 Price Each
FX-80MR-ES 711-4606 Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-128MR-ES 711-4618 FX-32ER-ES 711-4837
FX-48ER-ES 711-4849

Unpowered Extension Block -


Digital I/O
Networking - FX family
The FX-485 1:N data network allows a
computer or similar intelligent device to 26
become
the master station of a small local net-

Industrial Computing & PLC's 857


work. The master device is connected to
the network by the FX-485PC-IF interface.
This allows a serial transmission (RS232)
from the host or master device to be con-
verted into the required wire transmis-
sion format. The FX network supports
both RS422 and RS485 formats with 16
slave stations spread over a distance of up
to 500 metres. The FX data network offers the opportunity to build integrated systems
where many machines and/or operations, with independent control, can be linked to a
central point for monitoring, data acquisition and logging. This interface can be used to
Available in 4, 8 and 16 point sizes
construct a network with Mitsubishi programmable controllers fitted with FX-485ADP
Available as 24V dc input blocks, relay output blocks or with the FX-8ER-ES as a
adaptors.
combined block offering 4 inputs and 4 outputs
Optional DIN rail or direct mounting Features include:
All input devices are isolated electrically (using opto-couplers) Choice of either 1:1 or 1:N communications with up to 16 stations when using the
All relay outputs devices are isolated mechanically 1:N configuration
Provides a cost-effective and reliable method of implementing full factory control
An FX system can be built up to suit each individual users specific needs by using a
when used with a SCADA package
range of powered extension units, special function blocks and unpowered extension
Choice of RS422 or RS485 communication types
blocks. The unpowered extension blocks offer the ability to add 4, 8 or 16 points of
Up to 500m between master and last slave station
input or output (I/O) devices packaged into independent blocks. Adding additional I/O
Full opto-isolation on the communications lines means greater EMC protection
requires the insertion of the appropriate unpowered extension block onto the expan-
sion bus of the FX programmable controller. The unpowered extension blocks are a The FX-485ADP allows FX Main Processing Units (MPUs) to be connected as slave
cost-effective method of bridging the I/O gap between the I/O ranges of the FX main stations to the FX 1:N Data Network. Network communications are set up on the FX
processing units and the FX powered extension units. slave station by using 3 special data registers. All baud rates, stop bits, parities, data
I/O Points bits & sum checks are configurable to the users own needs. The FX 1:N Data Network
Total I/P O/P Unit Size Weight Mftrs List No. Order Code has two built-in protocols; however, users can develop their own by utilising the new
8 4 4 45 x 140 x 95 0.3 kg FX-8ER-ES 711-4825 communications instructions available with FX MPUs fitted with version 3.3 central
8 8 45 x 140 x 95 0.3 kg FX-8EX-ES 713-5506 processing units. The new applied instructions within the FX allow functions such as
16 16 73 x 140 x 95 0.5 kg FX-8EYR-ES 713-5518 HEX to ASCII, ASCII to HEX conversions and sum checking to be carried out.
8 8 45 x 140 x 95 0.3 kg FX-16EX-ES 713-5520
16 16 73 x 140 x 95 0.3 kg FX-16EYR-ES 713-5531 Features include:
Allows an FX unit to be connected to the FX 1:N data network
INC70
Can be configured to use either RS422 or RS485 communication protocols
Price Each Specifically developed to work with FX units with CPU versions 3.3 or greater
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+ Networks can be developed with distances up to 500m between the master station
FX-8ER-ES 711-4825 and the last slave station
FX-8EX-ES 713-5506 Size Weight Mftrs List No. Order Code
FX-8EYR-ES 713-5518 30 x 100 x 79 0.3 kg FX-485PC-IF 713-5610
FX-16EX-ES 713-5520 25 x 140 x 45 0.3kg FX-485ADP 713-5592
FX-16EYR-ES 713-5531 inc106

Price Each
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-485PC-IF 713-5610
FX-485ADP 713-5592

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 857
Industrial Computing & PLC's
Mitsubishi PLCs continued Active Communications Adaptor -
RS232
Parallel Link Adaptor Enables the FX to produce its own data files and reports,
Allows two FX Main Processing Units to be i.e. production quotas or maintenance points, directly onto
linked to provide a basic synchronisation a printer
between their individual programmes Facilitates connection to a wide range of data gathering
Can exchange 10 data words and 100 bit devices, i.e. bar code readers, tagging systems, etc
devices in each communication direction, Allows the FX to be used as a remote station, using a
i.e. the total system processes 200 bit modem to call in with status data and breakdown reports
devices and 20 data registers Communications can be initiated by the FX or from a central
Requires minimal set-up to achieve computer carrying out maintenance checks
immediate communication and simple use
of the PRUN Applied Instruction
All power requirements are serviced
through the bus connection to the FX Main
Processing Unit
Transmission medium: twisted pair (wire),
not included. Shielded cable should be
used for greatest EMC protection The FX-232ADP connects to the left-hand port of an FX main processing unit and
Transmission distance: 10 metres allows communication with a wide range of industrial RS232 compatible products,
One FX2-40AW unit required for each Main Processing Unit (MPU), therefore two including bar code readers, printers, computers and modems, etc. Control of the com-
units required for a system munications protocol uses a single applied instruction available in every version 3.3
(or greater) FX main processing unit.
The FX2-40 AW parallel link adaptor makes it possible to synchronise or co-ordinate
two operational machines, without using a full network solution. A typical application Modem control with the FX-232ADP is enhanced with an automatic carrier detect fea-
would be a conveyor where the controllers are working with common equipment. ture, allowing detection of telephone line connection.
Common control can be achieved by connecting one FX2-40AW to the left-hand port of Size Weight Mftrs List No. Order Code
each FX main processing unit and linking the two with a twisted pair cable. One main 25 x 140 x 45 0.2 kg FX-232ADP 711-5970
processing unit is then designated as the master unit, the other as slave to complete
inc79
the system set-up. 10 data registers and 100 bit devices can be exchanged in each
direction between the master and slave controllers. Price Each
Size mm Weight Mftrs List No. Order Code Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+
45 x 140 x 95 0.3 kg FX2-40AW 711-5891 FX-232ADP 711-5970
inc78

Price Each
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+ Analogue Input & Analogue Output
FX2-40AW 711-5891

Price Each
Order Code 1+ 5+ 10+

26 100m Reel 585-750


TX Cable

RS232 Serial Interface


Industrial Computing & PLC's 858

Converts RS232 to RS422 with added opto-


isolation on all communications lines
Can be used with all FX Main Processing Units 12 bit digital signal conversion for both analogue input and output blocks
(MPU), i.e. FX0, FX0N and FX Can operate in either a voltage or a current configuration with respective step
Can be permanently installed adjacent to the resolutions of 5mV and 30A
MPU of choice The FX-4AD analogue input block can operate at 6msec per channel in high speed
Comes complete with connection cable mode or 15msec per channel in normal mode
required for use with FX MPUs The FX-2DA analogue output block can operate at 3.5msec for both channels in
Requires no additional power source all high speed mode or 18msec in normal mode
power requirements are taken directly from A range of analogue blocks designed to meet the control needs of dynamic system
the communications lines integration and control. Analogue devices can be used to provide a wide range of input
information in addition to applying sensitive control over output devices. Analogue
applications include flow and pressure control, speed and light intensity and basic
temperature control. The FX-4AD is a 4 channel analogue to digital converter, whilst
the FX-2DA is a 2 channel digital to analogue converter. The FX-4AD and FX-2DA oper-
ate with 12 bit signal conversion and can be used in either a voltage or a current con-
figuration.
The FX-232AW is a serial interface which allows computers and intelligent machine Unit Type Channels Size Weight Mftrs List No. Order Code
interfaces to be connected to the programming port of all FX family controllers (FX0, Analogue input 4 73 x 140 x 95 0.5 kg FX-4AD 711-5258
FX0N and FX). The function of the FX-232AW interface is to convert RS232 communi- (Analogue to Digital)
cations to RS422 as used by the communications port of the Mitsubishi programmable Analogue Output 2 73 x 140 x 95 0.5 kg FX-2DA 711-5260
controllers. Additionally, the unit provides full opto-isolation on the communications (Digital to Analogue)
lines, protecting the connected programmable controller from over-voltages and EMC
inc72
noise, etc. The FX-232AW may be permanently installed next to the main processing
unit using the cable included. For connection to FX0 and FX0N programmable con- Price Each
trollers, the adaptor cable FX-20P-CADP is also required. Mftrs List No. Order Code 1+ 2+ 5+ 10+ 20+
Size Weight Mftrs List No. Order Code FX-4AD 711-5258
45 x 140 x 95 0.3 kg FX-232AW 711-6100 FX-2DA 711-5260
inc82

Price Each
Mftrs' List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-232AW 711-6100
Major International
Brands
All the leading brand names from over
1,000 major international manufacturers.

858 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Temperatuire Sensing Inputs Pulse Train Output Block
Platinum Resistance PT100 & J & K
Maximum 100kpps output train
The FX-2AD-PT is equipped with 12 bit conver- Seven built-in operating modes
sion providing the FX Main Processing Units Operates with 32 bit accuracy and
(MPUs) with a digital temperature reading in the allows multiplication factors of 100, 101,
range of -100C to +600C. The control and 102 and 103 when used for positioning
operation of the FX-2AD-PT is accessed by the data
FX applied instructions TO and FROM. The use Four command units as standard:
of the FX-2AD-PT can be enhanced by combin- pulse, micro-metres, mdeg and 10-4
ing it with analogue-to- digital and digital-to- inches
analogue devices, such as the FX-4AD and FX- One FX-1PG-E controls a single inde-
2DA. Applications of a combined system include pendent axis. However, up to 8 special
control of office, house, factory environments, function blocks can be connected to an
etc, where analogue operational limits could be FX system
controlled from a rheostat/potentiometer and For a closed loop system, use with the
digital inputs using a thumbwheel/keypad. high speed counters of the FX base
units
The FX-1PG-E single axis positioning control module has 100kpps (kilo-pulses per
Features include: second!) digital output. Extra inputs directly on the unit allows connection of switches
Temperature readings can be made in Centigrade or Fahrenheit which may require a speedy response. The FX main processing unit controls the oper-
2 input channels for the PT100 (3 wire) thermocouples ation of the FX-1PG-E through the use of the TO and FROM applied instructions.
Resolution: 0.2C
Accuracy: 1% F.S. (of the compensated temperature range) It is possible to control more than one independent axis through the connection of
additional FX-1PG-E units to the FX system. Typical FX-1PG-E applications include X-Y
The FX-4AD-TC, thermocouple sensor module has 4 channels which can be indepen- table control and motor speed control.
dently configured to read either K or J type thermocouples. The FX-4AD-TC requires no
complicated programming and is controlled using the standard TO and FROM applied Size Weight MftrsList No. Order Code
45 x 140 x 95 0.3kg FX-1PGE 711-5805
instructions of the FX. Typical applications include controlling muffle furnaces, small inc76
ovens, molten plastic temperatures or even die temperatures when extruding alumini-
um. The active temperature ranges are dictated by the type of thermocouple used: K- Price Each
type device can operate between -100C to +1200C & J-type thermocouples can oper- Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 20+
ate between -100C and +600C. FX-1PG-E 711-5805
Features include:
Four independently configurable channels for use with K- or J- type thermocouples
12 bit analogue data values Memory Cassettes
Access to Centigrade and Fahrenheit data immediately without having to econfigure Small and durable construction, ideal forsending out program updates
the unit The Real Time Clock (RTC) Cassette and the FX-EEPROM-4C have automatic leap
Resolution: K-type thermocouples 0.4C, J-type thermocouples 0.3C year compensation until the year 2079. RTC features can be used to increase eco-
Accuracy: 0.5% F.S. + 1C nomic operation
Size Weight Mftrs List No. Order Code All EEPROM and RTC cassettes and can be used with FXON For battery backup of
73 x 140 x 95 0.5 kg FX-2AD-PT 711-5271 real-time clock data, use FXON-40B
73 x 140 x 95 0.5 kg FX-4AD-TC 711-5428
inc73
All EEPROM and RAM cassettes can be used with FX series controllers, battery
backup is provided as standard

Mftrs' List No. Order Code 1+ 2+


Price Each
5+ 10+ 20+
EEPROM units can be overwritten many times, typically 10,000
Each memory cassette comes with an integral handle to make removal of the cas-
26
FX-2AD-PT 711-5271 sette from the programmable controller a quick and easy operation

Industrial Computing & PLC's 859


FX-4AD-TC 711-5428 The Mitsubishi range of memory cassettes is available in three formats, EEPROM, EEP-
ROM with added Real Time Clock and RAM. Applications include updating programs to
processors on site, through to changing an FX or FX0N machine set-up or operation
Potentionmeter Input Block sequence to produce different products. A variety of machine set up programs could
be held on individual memory cassettes.
Allows data to be entered into FX Main
Processing Unit without a programming tool The Real Time Clock functions allow the FX and FX0N units to control operations in
Data can be entered as an 8 bit analogue value real time situations. Applications include the operating times of heating systems to
(0 to 255) or as a position within an 11 position improve economy, etc. The use of memory cassettes with FX main processing units
switch (0 to 10) increases the available program steps from 2000 up to 4000 for EEPROM versions and
8 input channels (potentiometers) per unit 8000 steps for RAM versions.
Can be used with all FX Main Processing Units Memory Cassettes take priority over the program currently stored in the programma-
ble controller, therefore once a Memory Cassette has been inserted in to the controller,
the program on the cassette is executed. Once the Cassette is removed, the program-
mable controller will revert to the previously-stored program.
Memory Size Memory Real-Time Used Mftrs. Order
(in steps) Type Clock With List No. Code
4000 EEPROM no FX & FXon FX-EEPROM-4 714-9827
4000 EEPROM yes FX & FXon FX-EEPROM-4C 714-9839
8000 RAM no FX only FX-RAM-8 714-9840
The FX-8AV allows 8 separate values to be entered in to the FX simply by the twist of a - - yes FX & FXon FX-RTC 774-546
- - - FXon Battery Backup
screwdriver, thus avoiding changing any part of the FX program. Applications include - for RTC functions
timer adjustment, counter data, register data and activating different program features inc132
through selection of potentiometer value.
Mftrs. Price Each
The value of the potentiometers can be read using one of two applied instructions, List No. Order Code 1+ 2+ 5+ 10+ 20+
allowing the user the flexibility to treat the data from each potentiometer as either an 8
bit analogue value,(i.e. 0 to 255), or as an 11 position selector switch (0 to 10). FX-EEPROM-4 714-9827
FX-EEPROM-4C 714-9839
Size Weight Mftrs List No. Order Code FX-RAM-8 714-9840
45 x 140 x 95 0.3 kg FX-8AV 711-5411 FXRTC 774-546
inc75 FXON-40B 774-558
Price Each
continued
Mftrs List No. Order Code 1+ 2+ 5+ 10+ 20+
FX-8AV 711-5441

Free Same Day Delivery


For orders received before 12.30pm
we provide free same day delivery.

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 859
Industrial Computing & PLC's
Mitsubishi PLCs continued
The FX2N can be described as having advanced control features normally associated
Programmers and Data Access Units with PLC rack based products but housed in the body casing of a Micro PLC. As with
FX-20P-E Hand-Held Programmer all Mitsubishi PLCs the use and application of FX2N products provide simple solutions
as sophisticated problems.
The FX-20P-E hand-held programmer can be used with
FX2N range of PLCs can use all the Extension units, Expansion blocks and Special
FX0, FX0N and FX main processing units. The FX-20P-E
function blocks of the Micro FXON range in addition to its own FX2N dedicated units.
has a bright back-lit LCD screen with 4 lines of 16 charac-
This means the users can grow the control unit to suit the changing requirements of
ters displayed at any one time. Additional functions
the required tasks over time.
include forcing program elements ON or OFF and dynamic
All units Base Units have an onboard 24V dc power supply for input devices etc.
stepladder monitoring, useful during commissioning and
fault-finding. Powerful and easy to perform applied instructions
Features Include: Processing speed 80 nanoseconds (0.8microseconds) per basic instruction
Has a bright 4 line display providing ease of use in 8K step programme capacity built in, expandable to 16K steps with optional cas-
dark environments settes
Can store an 8000 step program within its own mem- Built in Real Time Clock and Calender (Y2K compliant - valid through 1980 to
ory for up to 3 days due to capacitive backup 2079)
An additional adapter cable (FX-20P-CADP) is Built in High Speed Counters, up to 60KH single phase, 30KHz 2 phase
required for connection to FX0 and FX0N main pro- 8000 Data registers (16 bit), 3072 internal flags
FX-20P-E
cessing units Pulse train output up to 20KHz
INC95 Base units may be configured with FX2N and FXON extension units and extension
blocks up to 256 I/O
Price Each Multiple communication and networking options - up to 9 RS232 ports can be
Mftrs. List No. Order Code 1+ 5+ 10+ added to FX2N base units. Other options include 485 multidrop, 1:N. N:N commu-
FX-20P-E 714-8999 nication methods etc.
FX-20P-CADP 276-352 LED status indication
Password security
Din rail or direct mounting options
Connecting Cables Applied instruction sets include: Program flow, data manipulation and comparison,
arithmetical and logical instruction including floating point, Square Root, SIN, COS and
276-388 (SCO7) Protocol Converter
instructions for inputs ad outputs. Communication instructions such as ASCII and
A cable and protocol converter in one. One end of the cable plugs into the PLC and the
HEX conversions, Sum checking instructions.
other end is terminated with a 9 pin D sub-connector.
Programming features include: on-line/off-line programming, on-line monitoring and
276-352 (FX-20P-CADP) Adaptor Cable For FXO/FXON testing. Remote Run/Stop control (users could use this feature to program/monitor
A 0.3m long cable adaptor which allows a 25 pin D sub-male connector to be plugged /control remotely over a modem) Advanced diagnostics and built in error checking in
into an FXO/FXON PLC. each FX2N PLC 3 levels of security via a password entry code system built in as stan-
720-6872 FX-20P-CAB Connection Cable for FX dard.
A 1.5m long cable which can be used with either an FX-20P-E(714-8999), FX-10DU-E Programming: via hand held programmer FARNELL stock no. 714-8999 or using a new
(276-376) or an FX-10P-E (276-315) to provide the communication link to an FX low cost but highly efficient and effective WIndows Y based programming package
Programmable Controller. Note: This cable is already supplied with the FX-20P-E. FARNELL stock nos. 725-8410
inc131 Note: As a quick check, the following notes should be used. Please note that the FX2N units can far
exceed the values quoted below, but the full congifuration rules need to be observed.
Price Each Base units up to 32 I/O can accept extra extension blocks up to 24 I/O
26 Order Code 1+ 5+ 10+ Base units from 48 I/O can accept extra extension blocks up to 48 I/O
Protocol converter 276-388
Adaptor cables 276-352 FX2N Base Units
Cable FX 720-6872
Industrial Computing & PLC's 860

GPP/WIN Software
GPP/WIN is a powerful Windows based programming tool for the full range of
Mitsubishi controllers.
Switch between instruction list and ladder diagram format
Access to all PLC parameters, network configurations and comment tables
Project navigator to provide clear overview of the entire project
Ability to use existing programs written using MELSEC MEDOC, FX-PCS-WIN,
GPPA and GPPQ
Program components can be copied between projects for reuse Inputs are configurable as being Sink or Source (NPN or PNP).
Windows 95, 98 and NT Wide power supply tolerance, 100 to 240V +10%/-15% 50/60Hz
inc263
24V DC service/sensor supply built in
Price Each Volt free relay isolated outputs can be used with up to 240V a.c. or 30V d.c.
Mftrs. List No. Order Code 1+ 5+ 10+ switching.
Inputs are opto isolated 24V d.c.
GPP/WIN 329-8863 Opto isolated Source (PNP) transistor outputs can be used signals from 5 to
30V dc inc205

Manuals for FXON PLCs Price Each


The Introductory Guide To Programmable Controllers (276-420) Mftrs. List No. Order Code 1+ 2+ 5+ 10+
An introductory book on the Mitsubishi Series of programmable controllers. It is suit- Relay Output
ed to personnel just entering the world of programmable controllers. 16 I/O FX2N-16MR-ES/UL 725-8045
101 Ways To Use A Programmable Controller (645-540) 32 I/O FX2N-32MR-ES/UL 725-8057
Provides more than a hundred examples with in-depth description of the application, 48 I/O FX2N-48MR-ES/UL 725-8069
graphic representation of the application and a detailed ladder logic program/solution. 64 I/O FX2N-64MR-ES/UL 725-8070
80 I/O FX2N-80MR-ES/UL 725-8082
Programming Manual (587-965)
128 I/O FX2N-128MR-ES/UL 725-8094
A comprehensive manual covering programming and applications of the FXON range
of PLCs. The manual gives considerably more detailed information than the instruc- Transistor Output
tion booklet supplied with each PLC. 16 I/O FX2N-16MT-ESS/UL 725-8100
PLC55X 32 I/O FX2N-32MT-ESS/UL 725-8112
48 I/O FX2N-48MT-ESS/UL 725-8124
Price Each 64 I/O FX2N-64MT-ESS/UL 725-8136
Order Code 1+ 5+ 10+ 80 I/O FX2N-80MT-ESS/UL 725-8148
FX introductory manual 276-420 128 I/O FX2N-128MT-ESS/UL 725-8150
101 Ways To Use A Programmable Controller 645-540
FX Programming Manual 587-965

860 Electronic, Electrical and Mechanical Prices are in Hong Kong Dollars

Farnell June 2001 Book 1 CYAN MAGENTA YELLOW BLACK Page 860 HONG KONG CATALOGUE
Industrial Computing & PLC's
Extension Blocks High Speed Counter
These blocks increase the capability or capacity when added to any powered base or This unit provides an independent high speed counter input to an FX2N system. The
extension unit. Extension blocks need only the signal lines and no other power source unit is controlled using TO/FROM instructions. There are hardware outputs which can
to operate. be triggered by an internal counter comparison feature to get very high speed respons-
INC206 es.
Price Each Note: For configuration purposes each this unit is considered as occupying 8 I/O
Mftrs. List No. Order Code 1+ 2+ 5+ 10+ points an FX2N system.
Unpowered Extension Blocks
Inputs
16 I/P FX2N16EX-ES/UL 725-8161
Inputs can be single or 2 phase up to 50kHz
16 O/P trans FX2N16EY-ESS/UL 725-8173
Single phase counters can be configured with 1 or 2 inputs
16 O/P relay FX2N16YR-ES/UL 725-8185
Two phase counters can be configured with 1, 2 or 4 edge counting profiles
Powered Extension Blocks Input Signals of 5V, 12V and 24V (Sink or Source) are accepted
16 I/P, 16 and 32 bit counter ranges are available
16 O/P Relay FX2N32ER-ES/UL 725-8197
Outputs
24 I/P,
12 to 24 V d.c. (0.3A max) sources can be controlled
24 O/P Relay FX2N48ER-ES/UL 725-8203
Optional outputs offer Sink or Source switching
24 I/P,
Hardwired outputs can automatically be triggered after the counter has reached
24 O/P Relay FX2N48ET-ESS/UL 725-8215
user defined predetermined values/limits
INC219

Mftrs. Price Each


Analogue Input/Analogue Output List No. Order Code 1+ 2+ 5+ 10+
All FX2N analogue blocks have 4 channels processing 12 bit analogue signals. They FX2N-1HC 725-8227
connect on to the FX2N in the same manner as an expansion block. Each analogue
block does require an additional 24V d.c. power source. Communication to each ana-
logue block is carried out using two simple instructions (TO/FROM) to read and write
data to the units own internal buffer memory and CPU. All analogue units have Single Axis Positioning Unit
optoisolation between digital and analogue circuits. The pulse train output, of upto 100kpps (kilo pulses per second), is designed for use
Note: for configuration purposes each analogue/temperature unit is considered as with either servo or stepper motors for positioning control. This unit is configured and
occupying 8 I/O points on an FX2N system. used by using the TO/FROM instructions of the FX2N base unit.
The unit offers predefined operating modes, in addition to the direct inputs for preven-
Analogue input (FX2N-4AD)/analogue output (FX2N-4DA)
tion of slow response errors.
Offset and gain can be set up for each channel providing accurate control Note: For configuration purposes this unit is considered as occupying 8 I/O points on
Analogue input values can be read directly or automatically averaged over a user an FX2N system.
defined number of readings
Each channel can be independently configured to operate with voltage or current
signals; -10 to +10V (both units), +4 to +20mA (both units), -20 to +20mA (ana- Pulse train output, of upto 10 to 100,000 pulses per second (pps) can be accom-
logue input only), 0 to 20mA (analogue output only) modated
INC207 Operational units can be specified as pulses/sec., cm/min, 10 deg/min and
inch/min
Mftrs. Price Each Predefined operating modes: jog operation, machine home position return, single
Desc
Analogue
List No. Order Code 1+ 2+ 5+ 10+ speed positioning operation, interrupt single speed positioning operation, two
speed positioning operation, external command (trigger) positioning operation, 26
In FX2N-4AD 725-8240 variable speed operation
Analogue INC220

Out FX2N-4DA 725-8276

Industrial Computing & PLC's 861


Price Each
Mftrs. List No. Order Code 1+ 2+ 5+ 10+
FX2N-1PG-E 725-8239
Thermocouple and PT100 Input
Current/present temperature is available in both centigrade and fahrenheit temper-
ature formats Variable Setting Board
Each unit automatically calculates the average over a user defined period (between The FX2N base units have the flexibility to be enhanced with additional function boards
1 and 4096 readings) in the same way as communication boards are added. The boards are added directly to
Each unit has its own dedicated diagnostics and error status information the base unit itself. The FX2N-8AV-BD offers users the ability to add 8 analogue pots,
Technical Specification
on a single board, which can be easily adjusted by operators (using a screwdriver).
The data is read from the setting pots using two special instructions which can inter-
Power supply 24V dc +/10%, 50mA pret the setting data as either an 11 position switch or as a data value from 0 to 255.
Current consumption 5V dc 40mA from base unit Such setting data can be used as timer durations, counter preset values or just as a
Channels 4 independantly configurable channels
simple way of entering a set data value without the need for a programming tool.
Thermocouple temperature characteristics
thermocouple active temp range resolution INC225

K type -100 to +1200C 0.4C


J type -100 to +600C 0.3C
Price Each
Mftrs. List No. Order Code 1+ 2+ 5+ 10+
Technical Specification - PT100 Input
FX2N-8AV-BD 725-8355
Power supply 24V dc +/10%, 50mA
Current consumption 5V dc 30mA from base unit
Channels 4 independantly configurable channels
PT100 input sensor temperature characteristics
active temp range resolution
-100 to +600C 0.2 to 0.3C
INC226
Major International
Mftrs. Price Each Brands
Desc. List No. Order Code 1+ 2+ 5+ 10+
Thermocouple FX2N-4AD-TC 725-8264 All the leading brand names from over
PT100 FX2N-4AD-PT 725-8252
1,000 major international manufacturers.

Open Late! Value Added Services


Dont forget were here to take your orders, Over 20 specialist services from
From 9am to 7pm Mon - Fri and calibration to cable assembly.
from 9am to 12pm on Saturday. For more information call 8104 8208.

Internet www.farnell.com Sales Tel 8104 8208 Sales Fax 8104 8268 861

Farnell June 2001 Book 1 CYAN MAGENTA YELLOW BLACK Page 861 HONG KONG CATALOGUE
Industrial Computing & PLC's
Mitsubishi PLCs continued S7-221 CPUs
10 I/O non expandable (6 in, 4 out)
Communications Boards 2 Kbytes programming memory
4 x 20kHz high speed counter
The FX2N base units have the flexibility to be enhanced with additional communication
Real time clock option
boards. These are added directly to the base unit itself. The available units are:
24V d.c. input
FX2N-232-BD INC261
This board provides RS232 communication with an suitable RS232 device, i.e, person-
al computers, printers, bar code readers and modems. Order Price Each
FX2N-422-BD Supply Output Mftrs. List No. Code 1+ 5+ 10+
The FX2N-422-BD is essentially a second programming port for the FX2N base unit. It 24V d.c. 24V d.c. 6ES7 211-1AA20 0XB0 313-9750
is also possible to interface any of the Mitsubishi range of HMIs through this port, this 120/230V a.c. Relay 6ES7 212-0BA20 0XB0 313-9761
would then make it possible to have two HMI units connected to a single PLC as a
standard solution.
FX2N-485-BD S7-222 CPUs
This is the RS485 board unit to attach the FX2N base unit on to a 1:N data collection
14 I/O expandable (8 in, 6 out)
network, or as a note on a multi-drop network (N:N)
2 Kbytes programming memory
FX2N-CNV-BD 4 x 20kHz high speed counter
This converter board allows the FX2N to use the FX0N range of ADP communication Real time clock option
adapters, i.e. FX0N-232ADP, FARNELL stock no.774-534. Using the FX0N communica- 24V d.c. input
tion adapters provides optoisolated communications options as well as the ability to INC267
communicate over long distances.
Note: Only one BD board may be fitted to each FX2N PLC at any one time. Application Order Price Each
boards; FX2N-232-BD, FX2N-422-BD, FX2N-484-BD, FX2N-CNV-BD, FX2N-8AV-BD. Supply Output Mftrs. List No. Code 1+ 5+ 10+
24V d.c. 24V d.c. 6ES7 212-1AB20-0XB0 313-9773
INC223
120/230V a.c. Relay 6ES7 212-1BB20-0XB0 313-9785
Price Each
Mftrs. List No. Order Code 1+ 2+ 5+ 10+
FX2N-232-BD 725-8306 S7-222 CPUs
FX2N-42-BD 725-8318 24 I/O expandable (14 in, 10 out)
FX2N-485-BD 725-8320 28 Kbytes programming memory
FX2N-CNV-BD 725-8288 6 x 20kHz high speed counter
In-built real time clock
24V d.c. input
Windows Programming Package. INC268

Windows based programming for the FX PLC Family Order Price Each
FXO, FXOS, FXON, FX, FXN2 (FX-PCS/WIN-E)
Supply Output Mftrs. List No. Code 1+ 5+ 10+
The latest in a successful range of PC based programming tools, FX-PCS/WIN offers 24V d.c. 24V d.c. 6ES7 214-1AB20-0XB0 313-9797
the user the ease and benefit of the Windows operating system along with 3 powerful 120/230V a.c. Relay 6ES7 214-1BB20-0XB0 313-9803
PLC programming editors, documentation, monitoring and testing facilities, FX-
PCS/WIN also offers the ability to import print files product for the DOS MEDOC pro-
26 gramming package.
INC208
Digital Expansion Modules
These are used to increase the capacity of the
Price Each S7-200 CPUs. A maximum of 2 modules can be used with the S7-222, up to 78 I/O. A
Mftrs. list No. Order Code 1+ 2+ 5+ 10+ 25+
Industrial Computing & PLC's 862

maximum of 7 modules can be used with the S7-224, up to 128 I/O. Connection is via
FX-PCS/WIN-E 725-8410 ribbon cable (supplied).
Specifications:
Inputs 24Vdc rated, sink/source, opto-isolated
Cable Relay Outputs Volt free 2A; 5-30 Vdc or 5-250Vac
Transistor Outputs 20.4-28.8 Vdc, 0.75A
Used for multi-drop connection to a master computer or data transfer with FX2N INC262
units
All cables 1m in length Order Price Each
inc231
Input Output Mftrs. List No. Code 1+ 5+ 10+
Price Each 4 4 transistor 6ES7 223-1BF20-0XA0 328-9941
Description Mftrs. List No. Order Code 1+ 2+ 5+ 10+ 4 4 relay 6ES7 223-1HF20-0XA0 328-9953
RS232 Comms FX-232-CAB-1 725-8367 8 - 6ES7 221-1BF20-0XA0 313-9815
RS422 Comms FX-422CAB 725-8379 - 8 transistor 6ES7 222-1BF20-0XA0 313-9827
RS485 Comms FX-422CAB0 725-8380 - 8 relay 6ES7 222-1HF20-0XA0 313-9839
RS232-422 8 8 transistor 6ES7 223-1BH21-0XA0 313-9840
Converter FX-232AWC 725-8392 8 8 relay 6ES7 223-1PH21-0XA0 313-9852
16 16 transistor 6ES7 223-1BL21-0XA0 328-9965
16 16 relay 6ES7 223-1PL21-0XA0 328-9977

Siemens PLCs
Simatic S7-200 Micro PLC Analogue Expansion Modules
The 2nd generation S7-200 offers small but powerful CPUs with flexible I/O that can be Provide analogue capability for the 222 and 224 CPUs
tailored to suit simple or complex automation tasks, giving the best optimised and low- Inputs are selectable via dip switches, variable outputs by connection
est-cost solutions. Easy-to-use, Windows based software unlocks the powerful, in- Inputs 12 bit resolution
built computing and communications features. The enhanced expansion modules allow Outputs 12 bit resolution (voltage), 11 bit resolution (current)
more flexible solutions which, coupled with the upgraded software, mean changing Module Type Configurations
from other solutions is easier than ever. 4 Input unipolar - 0 to 5V, 0 to 10V or 0 to 20mA
All models feature: bipolar - +/- 2.5V or +/- 5V
High speed 0.37s per instruction In-built power supply 2 Output +/- 10V, 0 to 20mA
4 Input / 1 Output Inputs: Unipolar 0 to 50mV, 0 to 100mV, 0 to 500mV, 0 to 1V, 0 to 5V, 0 to
2 x 20kHz pulse outputs PID instructions 10V, 0 to 20mA
1 x RS485 communications interface Bipolar - +/-25mV, +/-50mV, +/-100mV, +/-250mV, +/-500mV, +/-1V,
Specifications: +/-2.5V, +/-5V
Supply voltage 85-264Vac, 47/63Hz or 20.4-28.8Vdc Outputs: +/- 10V, 0 to 20mA
Supply for sensors 24Vdc, 180mA(221 & 222 CPU) or280mA(224 CPU) INC260
Inputs 24Vdc, 7mA opto-isolated (sink/source configurable)
Relay outputs Volt free 2A; 5-30Vdc or 5-250Vac Price Each
Transistor outputs 24Vdc,0.75A Input Output Mftrs. List No. Order Code 1+ 5+ 10+
INC257
4 - 6ES7 231-0HC20-0XA0 315-4348
- 2 6ES7 232-0HB20-0XA0 328-9990
4 1 6ES7 235-0HD20-0XA0 315-4350

862 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
AS-i Master Module Simatic S7-200 Micro PLC
Module used as an AS-i master on an AS-i network The 2nd generation S7-200 offers small but powerful CPUs with flexible I/O that can be
One AS-i master can be used with the S7-222CPU and two with the S7-224 CPU tailored to suit simple or complex automation tasks, giving the best optimised and low-
Each AS-i master can have up to 31 slaves connected to it (62 when version 2.1 est-cost solutions. Easy-to-use, Windows based software unlocks the powerful, in-
slaves become available) built computing and communications features. The enhanced expansion modules allow
Slaves can be digital or analogue and are available in a wide variety of input and more flexible solutions which, coupled with the upgraded software, mean changing
output types from other solutions is easier than ever.
The AS-i master can also perform diagnostics during the CPUs program cycle to All models feature:
identify faults on the bus e.g. faulty slaves High speed 0.37s per instruction In-built power supply
Manual contains all the information needed to install and run the modules, as well 2 x 20kHz pulse outputs PID instructions
as a number of worked examples 1 x RS485 communications interface
INC259
Specifications:
Price Each Supply voltage 85-264Vac, 47/63Hz or 20.4-28.8Vdc
Mftrs. List No. Order Code 1+ 5+ 10+ Supply for sensors 24Vdc, 180mA(221 & 222 CPU) or280mA(224 CPU)
Inputs 24Vdc, 7mA opto-isolated (sink/source configurable)
AS-i master 6GK7 243-2AX00-0XA0 329-0013
Relay outputs Volt free 2A; 5-30Vdc or 5-250Vac
Manual 6GK7 243-2AX00-8BA0 329-0025 Transistor outputs 24Vdc,0.75A
INC257

Optional Cartridges
A range of optional cartridges which allow the user to upgrade the functionality of Telemecanique PLCs
the CPU Nano Base units
The EEPROM memory module is used to transfer and back-up programs and store
data The IEC 1131 compliant Modicon TSX Nano PLC range offers versitility & flexibility at a
The real time clock can be added to the S7-221/222 CPUs low price. With 5 models of base unit to choose from ranging from 10 I/O through to
The battery module retains the integrity of the RAM, typically for 200 days 24I/O, and a range of accessories, the Nano PLC can be easily configured to the
requirements of your small PLC application. Communication protocols include,
INC269
Modbus, Unitelway, and ASCII, and up to 4 of the units can be simply networked to
Price Each share a common data area via their own internal communications link. Three models of
Mftrs. List No. Order Code 1+ 5+ 10+ the Nano PLC have a built in analogue input (0-10V) which can be used to measure
variables such as temperature, speed, level, flow, pressure etc.
Memory module 6ES7 291-8GE20-0XA0 313-9890
Clock module 6ES7 291-1AA20-0XA0 313-9888 Programming is performed in reversible Ladder Logic or Instruction List via PC based
Battery module 6ES7 291-8BA20-0XA0 313-9876 programming software, or Instruction List via a handheld programming terminal. The
addition of a simple program loader makes transfer of programs easy when no pro-
gramming devices are nearby.
S7-200 Cabling 10, 16, and 24 I/O expandable base units
14, and 20 I/O non expandable base units
PC/PPI cable is used for connection between a PC and the programming port on 10, 16, and 24 I/O non expandable base units with 1 analogue input (0-10V)
the CPU 10, 16, and 24 I/O low cost expansion units
Cable length is 5m Real time clock available on 14, 16, 20, and 24 I/O units
The expansion cable is used to connect between rows of modules only one per First input can be configured as a fast counter (up to 10KHz)
I/O chain Programmable input filters on all inputs (12ms, 3ms or 100s)

Price Each
INC270 1000 instruction RAM and EEPROM memory
Protect facility for PLC program (RAM and EEPROM) to restrict unauthorised 26
access
Mftrs. List No. Order Code 1+ 5+ 10+ In built 24vdc sensor supply (150mA) on AC powered units
PC/PPI cable 6ES7 901-3BF20-0XA0 313-9967

Industrial Computing & PLC's 863


ASCII or Unitelway protocols via programming port
Expansion cable 6ES7 290-6AA20-0XA0 313-9864 Modbus slave protocol via extension port
Built in analogue timer(s)
Relay outputs on all units
S7-200 Manual Simple networking of up to 4 units via extension link configured via selector switch
Removable terminal covers
The manual provides information about installing and programming the S7-200 INC255
range
Designed for both novice and expert users alike Price Each
INC271 Mftrs. List No. Order Code 1+ 5+ 10+
Price Each Non-expandable
8 In/6 Out TSX073L1428 321-4990
Mftrs. List No. Order Code 1+ 5+ 10+
12 In/8 Out TSX073L2028 321-5131
6ES7 298-8FA21-8BH0 313-9906
Base Units, extendable, 24V
6 In/4 Out TSX07301022 321-4977
9 In/7 Out TSX07311622 321-5003
STEP 7-Micro Software 14 In/10 Out TSX07312422 321-5143
Closer resemblance to Microsoft products Base Units, extendable, 110/240V
Improved editing 6 In/4 Out TSX07301028 321-4989
Improved wizards 9 In/7 Out TSX07311628 321-5015
STL and LAD programming languages 14 In/10 Out TSX07312428 321-5155
In-built PLC simulator 110/240V with integerated analogue input
IEC1131-3 compliant
6 In/4 Out TSX07321028 329-5722
The upgrade software enhances older versions to version 3.0 allowing them to be
9 In/7 Out TSX07331628 321-5027
used with 2nd generation S7-200
14 In/10 Out TSX07332428 321-5167
INC266

Price Each
Software Mftrs. List No. Order Code 1+ 5+ 10+ Nano Expansion Units
CD 6ES7 810-2BC00-0YX0 313-9920 Modicon TSX Nano PLCs can either be expanded by the addition of another expandable
Diskette 6ES7 810-2BA00-0YX0 313-9943 base unit (set to expansion via a selector switch), or via the addition of specific low
Upgrade cost expansion units. These units are available in sizes of 16 and 24 I/O. A maximum of
CD 6ES7 810-2BC00-0YX3 313-9931 one expansion unit can be added to a Modicon TSX Nano PLC.
Diskette 6ES7 810-2BA00-0YX3 313-9955 INC253

Price Each
Supply I/O Mftrs. List No. Order Code 1+ 5+ 10+
110/240V 9 In/7 Out TSX07EX1628 329-5710
110/240V 14 In/10 Out TSX07EX2428 321-5179

continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 863
Industrial Computing & PLC's
Telemecanique PLCs Micro Digital I/O Modules
The I/O modules for the Modicon TSX Micro PLCs are supplied complete with terminal
Nano Handheld Programming Devices blocks, and are available in two formats
The handheld programmer for the Nano PLC offers programming and monitoring in Full Height Modules
List language. It can also be used to adjust variables in either the Nano or Micro PLCs. Half Height Modules
It has its own RAM memory which will store a single program for approximately on With the exception of the first slot (which can only accept a full height module), one
hour, and additional Flash Prom memory which will store a single program indefinitely, slot within the Micro PLC rack can be taken either by one full height module or by two
and the ability to add a PCMCIA card into the bottom of the unit which can store up to half height modules. These can be a mix of digital, analogue, safety, or AS-i modules.
6 programs. The 24Vdc input modules have a switch on the card for selecting sink or source mode
The program loader enables a program to be extracted from a Nano or a Micro PLC (PNP/NPN).
(up to 16K words), stored indefinitely, and then if required transferred to another Nano Full height modules are available in the following variants
or Micro PLC. The simplicity of operation via a single button, and the small physical 32 Inputs (24Vdc)
size means that this feature is extremely useful when program modifications need to 32 Outputs (Relay)
be sent to a remote location, or when loading of the program into multiple PLCs is 16 Inputs (24Vdc) / 12 Outputs (Relay)
required. Half height modules are available in the following variants
INC254
12 Inputs (24Vdc)
Price Each 8 Outputs (Relay)
Mftrs. List No. Order Code 1+ 5+ 10+ 8 Input Emergency Stop / Limit Switch Monitoring Module (Safety Relay Module)
INC247
Programmer TFTX11071E 321-5192
EEPROM, 32K TFTXREM3216 321-5209 I/O Price Each
Program Loader TSXPRGLDR 321-5416 Configuration Size Mftrs. List No. Order Code 1+ 5+ 10+
12 In Half TSXDEZ12D2 321-5544
32 In Full TSXDEZ32D2 329-5746
Nano Programming Software 8 Out Half TSXDSZ08R5 321-5623
The programming software package for the Modicon TSX Nano PLC is supplied com- 32 Out Full TSXDSZ32R5 321-5635
plete with the interface cable to connect between the PC and PLC, a programming and 16 In, 12 Out Full TSXDMZ28DR 321-5600
installation manual, and the software on 36" disks. This simple user friendly software
package is IEC 1131-3 compliant, and offers programming in Ladder Logic or
Instruction List, and complete transfer and monitoring facilities for the PLC application, Safety Relay Modules
ensuring swift, programming, diagnostics, and commissioning. This unique module enables the substitution of a standard safety relay module, and the
IEC 1131-3 compliant integration of this function into the Modicon TSX Micro PLC. The module conforms to
Full programming in reversible Ladder Logic or Instruction List EN 954-1, and has BG & INERIS approval.
Full monitoring facilities in reversible Ladder Logic or Instruction List
Ability to document program with both Symbols, and Addresses Module contains a Preventa hard-wired
Ability to force I/O and Data safety relay 2 N/O safety output circuits, category 3
Full transfer facilities between PC and PLC RAM and EEPROM Monitoring of 1 to 4 dual (or single), normally closed contacts in pushbuttons,
Includes connection cable, disks, and manual emergency stops or limit switches on safety guards for an emergency stop or
INC256 immediate safety stop system (category 0)
Used to interrupt one or more emergency or safety stop control circuits in com-
Price Each plete safety
Mftrs. List No. Order Code 1+ 5+ 10+ Safety module independent of the Micro PLC processor
26 TLXLPL707P30E 321-5180 PLC diagnostics performance
Inputs 4 emergency stops or limit switches (dual or single contacts)
1 start button
24V
Micro base units
Industrial Computing & PLC's 864

Safety outputs 2 N/O (volt free), 1.25A


Modicon TSX Micro base units come in 2 styles, either as a 2 slot non expandable rack Connection Via screw terminal block
INC248
complete with some I/O but with room to add an extra I/O module, or as an empty 3
slot rack expandable to 5 slots in which the user can configure exactly the I/O required Price Each
for the application. Mftrs. List No. Order Code 1+ 5+ 10+
All units have the following TSXDPZ10D2A 321-5647
Die Cast backplate suitable for DIN rail mounting or screw fixing
24Vdc Sensor supply (400mA) on AC Powered Units
Solid rack with I/O module guides Analogue I/O Modules
Built in Multi purpose display allowing display of I/O, diagnostic information, AS-i
node and bus data, and up to 16 of the PLCs data registers. The Analogue I/O modules for the Modicon TSX Micro PLCs are half height modules,
Processor reset button (recessed) have individually configurable channels, and are supplied complete with terminal
Memory configurable for program or data (size dependant on unit) blocks. They are programmed using true engineering units, and are available in the fol-
Up to 16 event tasks lowing formats:
Up to 16 PID loops 4 channel multirange input module (0-10V,+/- 10V, 0-5V, 0-20mA, 4-20mA,
ASCII, Unitelway, or Modbus Slave communication via programming port B,E,J,K,L,N,R,S,T,U type thermocouples, Pt100, Ni1000)
The TSX3705 PLC has 28I/O as standard, and can be expanded to 60I/O, and the 8 Channel input module (0-10V, +/-10V)
TSX3708 has 56I/O, and can be expanded to 88 I/O. 8 Channel input module (0-20mA, 4-20mA)
The TSX3721 PLCs allow total user configuration and have extra features such as 2 Channel output module(,+/- 10V, 0-20mA, 4-20mA)
INC234
3 slot rack expandable to 5 slots
Dual programming port for connection of an HMI Price Each
Larger memory Type Mftrs. List No. Order Code 1+ 5+ 10+
PCMCIA memory expansion port
PCMCIA communications port 4 In TSXAEZ414 321-5659
The ability to add an AS-i master module 8 In-Voltage TSXAEZ801 329-5758
8 In-Current TSXAEZ802 321-5660
The TSX3722 PLCs again allow total user configuration and are identical to the 2 Out TSXASZ200 321-5672
TSX3721 PLCs, but with the addition of
8 Analogue inputs, and 1 Analogue output integrated into the rack
A 10KHz up / down fast counter integrated into the rack
A 10KHz up counting fast counter integrated into the rack AS-i Master Module
INC244 The Modicon TSX Micro PLC has the versatility of hosting an integrated AS-i bus mas-
ter connection via the addition of an AS-i Master module. This module enables pro-
Price Each
gramming of AS-i nodes and I/O just as if they were standard PLC I/O (simply using
1 free slot Supply Mftrs. List No. Order Code 1+ 5+ 10+ contacts and coils), so no complex programming is required. Within the PLC program-
16IN/12 OUT 110/240V TSX3705 028DR1 321-5428 ming software standard Telemecanique AS-i components are selectable from a menu
32IN/24 OUT 110/240V TSX3708 056DR1 321-5430 so configuration and programming of the entire bus is easy. Complementing the PLC
3 free slots - TSX3721 is an AS-i power supply which is supplied in the same form factor as the PLC to stan-
110/240V TSX3721 001 321-5453 dardise panel design.
INC235
24V TSX3721 101 321-5465
3 free slots - TSX3722 Price Each
110/240V TSX3722 001 321-5477 Mftrs. List No. Order Code 1+ 5+ 10+
24V TSX3722 101 321-5489 Master TSXSAZ10 321-5751
Power supply TSXSUPA02 321-5763

864 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
INC245
Accessories
Price Each
Extension rack 1 per PLC
Slot cover protects the PLC from ingress of dirt etc. when slots are not utilised Mftrs. List No. Order Code 1+ 5+ 10+
Battery provides backup for the PLC TLXCDPL7MP33M 321-5775
INC236

Mftrs. Price Each


List No. Order Code 1+ 5+ 10+ Omron PLCs
Extension rack - 2 slot TSXRKZ02 321-5519 Micro PLCs - 'CPM1A' Series
Empty slot cover TSXRKA01 321-5520
Lithium Battery TSXPLP01 321-5532

Micro Memory Cards


Modicon TSX Micro PLCs Memory expansion cards can be used to expand the memo-
ry of TSX3721 and TSX3722 PLCs from the 20Kwords standard memory to 64Kwords.
These type 1 PCMCIA cards are available in RAM or Flash Prom format and simply
plug into the front of the processor unit to expand the standard memory.
When only the standard base unit memory is used (20Kwords) then a memory backup
card can be used to store a program, and/or reload the program at a remote location.
This function is available without the need for a PC and automatically overwrites the
existing RAM and Flash Prom, at the same time forcing the PLC into RUN mode.
INC246 The new 'CPM1A' series micro PLC from Omron offers exceptional functionality.
Price Each Expandable up to 100 I/O and with analogue capability, the 'CPM1A' series is ideally
suited to both basic and more advanced applications. Available with relay and transis-
Mftrs. List No. Order Code 1+ 5+ 10+
tor outputs and with AC and DC supply, the 'CPM1A' series is available in 10, 20, 30 &
RAM TSXMRP064P 321-5490 40 I/O with 20 I/O and analogue expandability.
Flash EPROM TSXMFP064P 321-5507
Backup Card TSXMFPBAK032P 329-5734 Features Include:
Flash memory - no need for batteries Interrupt Processing
Analogue timers Input filters
Communication Options High speed counters Large instruction set -including
2K program memory Arithmetic
The Modicon TSX Micro PLC can communicate via its programming port using the fol- Password security access 128 timers/counters
lowing protocols ASCII, Modbus Slave, Unitelway Master and Unitelway Slave. Built in 24Vdc service supply Pulse output function
The TSX3721 and TSX3722 Micro PLCs can also communicate via the addition of User definable RS232 port - 1000 Data Registers
PCMCIA communications module which plugs into the PCMCIA port on the front of the (Adaptor required) UL & CSA approved
PLC processor. These are available in the following formats
Specifications:
RS232 Multiprotocol (ASCII, Unitelway Master, Unitelway Slave, Modbus Master, Supply/voltage 85-264 VAC, 50/60 Hz or 20.4 - 26.4 VDC
Modbus Slave, Jbus Master, Jbus Slave) On board DC service supply 200mA (10/20 I/O): 300mA (30/40 I/O)
RS485 / RS422 Multiprotocol (ASCII, Unitelway Master, Unitelway Slave, Modbus Inputs 24 VDC, 5mA, Opto isolated NPN/PNP configurable
Relay output Volt free 2A, 250V AC: 2A, 24 VDC
Master, Modbus Slave, Jbus Master, Jbus Slave)
High Speed Modbus Plus Connection (1mb/s)
PNP transistor outputs
Dimensions:
24 VDC, 0.3A/point
AC models DC models
26
Each of these modules requires the corresponding cable H W D H W D
INC242
10 I/O 6 Inputs 4 Outputs 90 66 85 90 66 50

Industrial Computing & PLC's 865


Price Each 20 I/O 12 Inputs 8 Outputs 90 86 85 90 86 50
30 I/O 18 Inputs 12 Outputs 90 130 85 90 130 50
RS232 Mftrs. List No. Order Code 1+ 5+ 10+ 40 I/O 24 Inputs 16 Outputs 90 150 85 90 150 50
Module TSXSCP111 321-5684 Mftrs. List No: CPM1A-10CDR-A=199-783, CPM1A-20CDR-A=199-795,
Cablee TSXSCPCD1030 321-5696 CPM1A-30CDR-A=199-801, CPM1A-40CDR-A=199-813,
RS485/422 CPM1A-10CDR-D=199-825, CPM1A-10CDT1-D=199-837,
Module TSXSCP114 321-5702 CPM1A-20CDR-D=199-849, CPM1A-20CDT1-D=199-850,
Cables: CPM1A-30CDR-D=199-862, CPM1A-30CDT1-D=199-874,
RS485/422/Uni Telway TSXSCPCM4030 321-5714 CPM1A-40CDR-D=199-886, CPM1-40CDT1-D=199-898
PLC43
RS485/422/Modbus/
Jbus/ASCII TSXSCPCM4030 321-5726 Price Each
Modbus Plus Type Outputs Order Code 1+ 5+ 10+
Module TSXMBP100 321-5738 AC Units
Cables TSXMBPCE030 321-5740 10I/O Relay 199-783
20I/O Relay 199-795
30I/O Relay 199-801
PL7 Micro Programming Software 40I/O Relay 199-813
DC Units
The PL7 Micro programming software package for the Modicon TSX Micro PLC is sup-
10I/O Relay 199-825
plied complete with the interface cable to connect between the PC and PLC, program-
10I/O PNP 199-837
ming manuals on CD ROM, and the software on CD ROM. This simple user friendly
20I/O Relay 199-849
software package is IEC 1131-3 compliant, and offers programming in Ladder Logic,
20I/O PNP 199-850
Instruction List, or Sequential Function Chart. The software enables the user to pro-
30I/O Relay 199-862
gram in Windows 95, 98 or NT4.0 environment and offers complete program transfer,
30/I/O PNP 199-874
debug, and monitoring facilities for the PLC application, ensuring swift, programming,
40I/O Relay 199-886
diagnostics, and commissioning.
40I/O PNP 199-898
An important benefit of this software package is the ease of configuration and pro-
gramming of an AS-i bus, where no complex code is required. The bus is simply con- continued
figured, and the nodes selected from a list, and then the I/O point programming is
done using standard Ladder Logic Contacts and Coils.
IEC 1131-3 compliant
Easy graphical configuration
Full programming in Ladder Logic, Instruction List or Sequential Function Chart
Full monitoring facilities in Ladder Logic Instruction List or Sequential Function
Chart
Open Late!
Ability to document program with both Symbols, Addresses, and Rung Comments
Ability to force I/O and Data Dont forget were here to take your orders,
Ability to divide program into multiple sections if required
Full transfer facilities between PC and PLC RAM and Flash Prom From 8.30am to 6.30pm Mon - Fri and
Includes connection cable, disks, and manual from 9am to 12pm on Saturday.
Program loader, Order Code 321-5192, can also be used with the Micro (up to 16K
words).

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 865
Industrial Computing & PLC's
Extremely user friendly IEC 1131/III Comprehensive documentation and
Omron PLCs continued compliant windows based program- commentry
Expansion Units. ming and documentation software Import and export "block" building
Has extensive monitoring and diagnos- Enables a structured approach to pro-
For 'CPM1A' Series
tic facilities for fault gramming
finding and commisioning
Choice of program editors
PLC46

Price Each
Mftrs List No. Order Code 1+ 5+ 10+ 25+
Software SYSWINCPM1 199-977

Programmable Software OMRON


Digital I/O Expansion Unit Analogue I/O Expansion Unit For all 'C' Series PLCs
H=90, W=86, D=50 H=90, W=65, D=50

The 30 and 40 I/O CPUs have expansion capability using either a 20I/O digital unit or a
2 channel input/1 channel output analogue expansion unit. Up to 3 expansion units
may be added to the main CPU unit. Relay and transistor output versions available.
Power is supplied from main CPU.
Specification: Analogue I/O Units
2 analogue inputs (0-10V, 1-5V, 4-20mA)
1 analogue output (0-10V, -10 to + 10V, 4-20mA)
Specification: Digital I/O Units
Inputs 24VDC, 5mA, Opto isolated, NPN/PNP config
Relay Output Volt Free 2A@250VAC; 2A@24VAC
PNP Output 24VDC, 0.3A/point
Mftrs. List No: CPM1A-20EDR=199-904, CPM1A-20EDT1=199-916, CPM1A-MAD01=199-928
PLC45

Output Order Price Each Extremely user friendly IEC 1131/III compliant windows based programming and
Type Code 1+ 5+ 10+ 25+ documentation software
Has extensive monitoring and diagnostic facilities for fault finding and comission-
Digital I/O Expansion Units
ing
12 Inputs, 8 Outputs Relay 199-904
Choice of program editors
12 Inputs, 8 Outputs PNP 199-916
Comprehensive documentation and commentry
Analogue I/O Expansion Unit Import and export for program "block" building
2 Inputs/ Output Analogue 199-928 Enables a structured approach to programming
Programs all Omron C Series PLCs
CQM1-CIF02 is a 2m cable and adaptor that converts the perpheral port on the CPU
Communication Adaptors/Cables to RS232 and can be used for many Omron programmable controllers
For 'CPM1A' Series RS 232CABLE is a standard RS232 cable which connects directly into the CPU

26 RS232 port and can also be used to program Omron HMIs NT11S and NT20S
PLC79

Price Each
Mftrs. List No. Order Code 1+ 5+ 10+ 25+
Industrial Computing & PLC's 866

Software SYSWIN 201-406


RS232 Adaptor Cable CQM1-CIF02 737-483
RS232 Standard Cable RS232Cable 199-965

Programming Console
For all C Series PLCs
Has a two line LCD display
Enables programming of all codes
Allows access to all data memories,
timers/counters and other data areas on
A choice of RS232 and RS422 DIN rail mounting adaptors are available for program- PLC
ming via PC using Omrons Syswin programming software. Connector can be made Supplied with a 2m cable
using the 2m RS232 cable listed below
PLC44

Price Each
Mftrs List No. Order Code 1+ 5+ 10+ 25+
RS232 CPM1-CIF01 737-460
RS422 CPM1-CIF11 737-471
RS232 Cable _ 199-965 H=190, W=90, D=35
PLC154

Price Each
Programming Software Mftrs. List No. Order Code 1+ 5+ 10+ 25+
For 'CPM1A' Series CQM1-PRO01-E 737-513

IMO PLCs
K10 Series Micro

H=80, W=120, D=65

866 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
The K10 micro PLC is a cost effective, block type unit offering 14 I/O (8 I/P, 60/P)
The IMO PLC Software and Programming Tools
Features include:
The IMO PLC software CD is supplied free of charge with
800 step EEPROM memory 48 timers and 16 counters
each purchase of an IMO PLC or HMI.
Processing speed 3.2 to 7.7 sec 16 100 step sequence controllers
per step 256 auxiliary and 128 retentive relays Easy to use IEC 1132-3 compliant Windows based pro-
Built in 8kHz high speed counter 64 data registers gramming simulation and documentation software
Integral RS232 interface Windows 95 drag and drop software Programming can be in either relay ladder sequential
Integral RS485 interface enabling up included fucntion or chart or statement list
to 32CPU's to be linked Enables forcing of inputs/outputs Custom function blocks and custom library can be cre-
3 year guarantee Enables change of timer/counter ated enabling complex programs to be broken down
185 instructions values Programs can be programmed locally or remotely via
Modem or Fnet
Operating voltage 85-265Vac On-line programming modifications possible
Inputs 24Vdc Off-line program simultation can be achieved
Outputs Volt free relay, 2A @ 240Vac or 3Vdc Powerful editing tools available
PLC189 Comprehensive program documentation

Price Each
Mftrs.List No. Order Code 1+ 2+ 5+ 10+ 20+ INC272

K14PI-DRS-FAR 310-0911 Mftrs. Order Price Each


Part No. List No. Code 1+ 2+ 5+
K10 to programmer cable KLC-010 310-1022
Basic PLC Starter Kit K30/K60 to programmer cable KLC-15A 310-1046
G series to programmer cable KLC-50A 327-7288
PLC to PC converter KLA-009 310-1034

G Series CPU
The IMO G6 is a very compact modular programmable con-
troller offering extremely high performance-
Upto 256 I/O
High speed processing with dedicated MPU 0.5 sec per
step
Memory capacity 17ksteps
Conform to elements of the IEC1131-3 standard (IL/LD/SFC)
PID control, computer link, high speed counter
Programming software CD provided
The IMO PLC starter kit is an ideal introduction into PLCs. It includes the small high
Specification
function K10S1 Programmable Controller, KGLWIN Windows based programming soft- Item GM6-CPUA GM6-CPUB GM6-CPUC
ware, all cables and the IMO CD ROM which includes all user manuals and a simple
Operation method Cyclic Operation, interrupt task method
Programmable Controller Tutorial. I/O control method Scan synchronised batch processing (refresh method)
The kit includes IMO K14P1-DRS PLC, KLC-010 programming cable, KLA-009 PC
adaptor and KGLWIN Software CD.
PLC242
Prog lang IEC1131-3 IL (instruction list), LD (ladder diag.) SFC

Operator (LD:13, IL:21), Basic (194), Basic Book (11) Special block
26
Number of instructions (dedicated function block special modules)
Price Each Processing speed Operator (0.5usec), Basic (0.5usec), Basic Block (0.5usec)

Industrial Computing & PLC's 867


Description Order Code 1+ 5+ 10+ Programming memory 68Kbytes (17L steps)
I/O points 128 points ( 16 point modules), 256 points (32 point modules)
PLC starter kit 353-2720 Direct variable area (2 to 8 Kbytes)
Data memory Symbolic variable area (32kbytes - direct variable area)
Timer No limitations in points : range 0.001 to 4,294,967,295 (1,193hrs)
Counter No limitations in points : range -32,768 to +32,767
PLC & HMI Starter Kit Operating modules RUN, STOP, PAUSE, DEBUG
Pwr failure protection Set to retain variables at data declaration
No of prog blks (128), Scan program (100), Time driven tasks (8), Ext
Program types interrupt tasks (8), Internal tasks (8), Initialisation prog (1)
Watchdog timer, memory error detetection, I/O error detection, battery
Self diagnostic functions error detection, power supply error detection
Re-start modules Cold, warm, hot
PID, RTC, RS485, High speed counter
Built-In functions RS232C link RS232 link PID, RS232C link
INC273

Price Each
Part No. Order Code 1+ 5+ 10+ 25+
GM6-CPUA CPU Standard 327-7290
GM6-CPUA CPU RS485, PID, RTC 327-7306
GM6-CPUA CPU PID, RTC, HSC 327-7318
The IMO HMI-PLC starter kit is an ideal introduction to HMI (Human GM6-CPUA PSU AC Standard 327-7320
Machine Interface) and Programmable Controllers. It includes the GM6-CPUA PSU AC Analogues 327-7331
IMO K10S1 PLC, the IMO MI2L20C display, KGLWIN Windows GM6-BO4M 4 I/O Slot 327-7343
based programming software, all programming cables, IMO-HMI GM6-BO6M 6 I/O Slot 327-7355
configuration software and the IMO CD ROM which includes all GM6-BO6M 8 I/O Slot 327-7367
users manuals and a simple introduction.
PLC243 continued

Price Each
Description Order Code 1+ 5+ 10+
PLC-HMI starter kit 353-2707

Major International
Brands
All the leading brand names from over
1,000 major international manufacturers.

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 867
Industrial Computing & PLC's
IMO PLCs continued G7 Micro Controller
G Series I/O
A wide choice of digital and analogue I/O in addition to special purpose
communication cards.
Removable terminal blocks
High speed response
RS232C and RS485 computer links
Fnet module option
Counter module option
Analogue, Fieldbus and DeviceNet modules
INC274
A series of micro programmable logic controllers offering program-
Part No. Order Price Each ming in the international IEC1131-3 programming language con-
Inputs Code 1+ 5+ 10+ 25+ forming to Instruction List IL, Sequential Function Chart SFC and
G6I-D22A 16 24VDC input (NPN/PNP) 327-7914 Relay Ladder LD. Free powerful GMWIN software, Windows based
G6I-D24A 32 24VDC input (NPN/PNP) 327-7926 Win 95,98 and NT is used. The same programming tools and soft-
G6I-D22B 16 24VDC input (source) 327-7938 ware is used as the IMO G6 PLC range.
G6I-D24B 32 24VDC input (source) 327-7940 The G7 can be expanded up to 80 I/O 48 I/P 32 O/P.
G6I-A11A 8 110VAC input 327-7951 Dedicated 32 bit CPU 128Kb RAM plus Flash memory
G6I-A21A 8 240VAC input 327-7963 Processing speed 0.5us/step 64Kb program capacity
Outputs 16kHz high speed counter Direct variable 2-8Kb
G6Q-RY2 16 2A relay output 327-8438 2kHz pulse output Symbolic variable 32Kb
G6Q-TR2A 16 Trans 0.5A (sink) 327-8440 PID autotuning function Timers unlimited 0.001-4,294,967.295
G6Q-TR4A 32 Trans 0.1A (sink) 327-8451 8 pulse catch inputs 0.2ms sec
G6Q-SS1A 8 Triac 100/240VAC 1A 327-8463 8 interrupt inputs 0.6ms Counters unlimited -32768 to 32767
Settable input filters 0-15ms Run, stop, pause, debug mode
Analogue I/O
2 built-in RS232 ports Ch1 fixed 38400 Number of program blocks 128
G6F-AD2A 4 channels 327-8475
bps, Ch2 supports Modbus Time driven tasks 8
G6F-DA2V 4 Voltage O/P 327-8487
master/slave plus user defined proto- External interrupt tasks 8
G6F-DA2I 4 current O/P 327-8499
col 1200-57600 bps Internal interrupts 8
High speed counter RS485 option (G7M-DR10A integral) Real time clock module (RTC)
G6F-HSCA 50kpps counter 327-8505 24V dc output External Flash memory module
Communications 205 instructions
G6L-FUEA 1Mbps 327-8517
Supply voltage: 110/240 AC Inputs: 24V dc 7ma opto isolated (sink/source)
G6L-CUEB computer link RS232 327-8529
Operating temperature: 0-50C Outputs: Relay 2 Amp 24V dc/240V ac
G6L-CUEC computer link R485 327-8530
External Dimensions
Description H W D Mftrs. List No. Order Code
K7 Micro Controller 6 in 4 out ac powered 75 95 115 G7M-DR10A 353-2501
12 in 8 out ac powered 75 145 115 G7M-DR20A 353-2513
18 in 12 out ac powered 75 145 115 G7M-DR30A 353-2525
24 in 16 out ac powered 75 175 115 G7M-DR40A 353-2549

26 36 in 24 out ac powered 75 225 115 G7M-DR60A 353-2550


PLC241

Price Each
Description Order Code 1+ 5+ 10+
Industrial Computing & PLC's 868

AC Supply
10 I/O 353-2501
20 I/O 353-2513
30 I/O 353-2525
40 I/O 353-2549
60 I/O 353-2550

A series of micro size programmable controllers which are simple


and cost effective, but offer the ultimate in power and versatility. IEC1131-3 PLC Starter Kit
The K7 is programmed using the simple but powerful Windows
based software, Windows 95,98 and NT KGLWIN as used by all of
the IMO K series PLCs.
The K7 can be expanded up to 80 I/O 48 I/P 32 O/P
Dedicated 32 bit CPU 248 instructions
Processing speed 0.5s/step 7K steps program capacity
16kHz high speed counter Auxilary memory 3072
2kHz pulse output Keep relays 512
PID autotuning function Link relays 1024
8 pulse catch inputs 0.2ms Timers 192 100ms 64 10ms
8 interrupt inputs 0.3ms Counters 256
Settable input filters 0-15ms Step control 99
2 built-in RS232 ports Ch1 fixed 38400 Data registers 5000
bps, Ch2 supports Modbus RUN, STOP, PAUSE, DEBUG mode
master/slave plus user defined proto- Real time clock module (RTC) The IMO IEC1131-3 starter kit is an ideal introduction into programming using the
col 1200-57600 bps External flash memory module international standard in programming PLCs. It includes the G7M-DR10A high function
RS485 option (K7M-DR10A integral) 24V dc output Programmable Controller, GMWIN Windows based programming software, all cables
Supply voltage: 110/240 AC Inputs: 24V dc 7ma opto isolated (sink/source) and the IMO CD ROM which includes all user manuals and a simple introduction to
Operating temperature: 0-50C Outputs: Relay 2 Amp 24V dc/240V ac using IEC1131-3
External Dimensions The kit includes IMO G7M-DR10A PLC, KIC-50A programming cable and GMWIN
Description H W D Mftrs. List No. Order Code
Software CD.
6 in 4 out ac powered 75 95 115 K7M-DR10S 353-2550 PLC244
12 in 8 out ac powered 75 145 115 K7M-DR20S 353-2562
18 in 12 out ac powered 75 145 115 K7M-DR30S 353-2574 Price Each
24 in 16 out ac powered 75 175 115 K7M-DR40S 353-2586 Description Order Code 1+ 5+ 10+
36 in 24 out ac powered 75 225 115 K7M-DR60S 353-2598
PLC237 IEC1131-3 PLC starter kit 353-2719
Price Each
Description Order Code 1+ 5+ 10+
AC Supply
10I/O 353-2550
20I/O 353-2562
30I/O 353-2574
40I/O 353-2586
60I/O 353-2598

868 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
PLC239
Extension Unit
Mftrs. List Price Each
No. Order Code 1+ 5+ 10+
G7F-RTC 353-2628

Real-time Clock Module


Plugs into expansion port
With full calendar year,
month, day and time con-
trol
Used by both G7 and K7
H=75, W=95, D=115
CPUs

Increases I/O capacity of base unit connected by ribbon cable (supplied)


No external power supply required to power module
Maximum 2 modules per CPU
Used by both G7 and K7 CPUs
Inputs: 60H 24V dc 7ma sink/source Outputs: 4 off relay Xamp 24V dc/240V ac
PLC236

Mftrs. Price Each


List No. Order Code 1+ 5+ 10+
G7E-DR10A 353-2604 PLC240

Mftrs. Price Each


List No. Order Code 1+ 5+ 10+
Analogue to Digital Converters
G7F-RTC 353-2653

RS232 Modem Interface


Allows for standard
modem connection
for remote communi-
cations
Used by both G7 and
K7 CPUs

H=75, W=95, D=115

Has two input channels and one output channel


Analogue input 0-10V 0-20mA 4-20Ma
26
H=75, W=95, D=115
Resolution 12 bit (0-4000)
PLC235
Analogue output 0-10V 0-20MA

Industrial Computing & PLC's 869


Conversion time scan time + 1.5ms per channel Mftrs. Price Each
Accuracy 0.5% full scale List No. Order Code 1+ 5+ 10+
Used by both G7 and K7 CPUs
PLC233 G7L-CUEB 353-2630

Mftrs. Price Each


List No. Order Code 1+ 5+ 10+
RS485 Communications Module
G7F-ADHA 353-2616
Allows for up to 32
PLCs to multidrop
Maximum 500
Program Back-up metres
Memory pack plugs into expansion slot Maximum 128000
Flash memory bps
Enables programs to be transferred to different PLCs Used by both G7 and
No battery required K7 CPUs
Used by both G7 and K7 CPUs
PLC238

Mftrs. Price Each


Description List No. Order Code 1+ 5+ 10+ H=75, W=95, D=115
Program back-up G7M-M256 353-2665 PLC234

Mftrs. Price Each


List No. Order Code 1+ 5+ 10+
Analogue Potentiometer Module G7L-CUEC 353-2641

continued

Free Technical Support


Our trained engineers are available to help
you select the right item. Call us on
(65) 788 1922 or e-mail
H=75, W=95, D=115 singapore-technical@farnell.com
Four analogue potentiometers can be used to manually adjust set points such as timers were here to help.
and analogue values without the need to use the programming software.
4 points 8 bits 0-200
Accuracy 2.0% (with full scale) Used by both G7 and K7 CPUs

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 869
Industrial Computing & PLC's
H W D Mftrs List No. Order Code
IDEC PLCs Expansion Unit 80 140 74 FC1A-E1A1E 179-951
Micro Expansion Units
MICRO-1 Starter Kit 2 I/P & 2 O/P 80 45 74 FC1A-M1BE 709-8911
4 I/P 80 45 74 FC1A-M1XE 709-8893
3 O/P 80 45 74 FC1A-MXAE 709-8900
Analogue timer unit 80 45 74 FC1A-TA1 710-1960
inc47

Price Each
Order Code 1+ 5+ 10+
Expansion Unit 179-951
Micro Expansion Units
2 I/P & 2 O/P 709-8911
4 I/P 709-8893
3 O/P 709-8900
Analogue timer unit 710-1960

MICRO-3 & 3C Base Units

Micro 1
Micro 18 inputs and 6 outputs, expandable to 16 inputs and 12 outputs using
expansion unit FC1A-E1A1E
Program capacity 600 steps using either programming unit or software
High-speed scan (8s per instruction)
Relay logic programming
80 timers (0 to 999.9s)
45 counters (0 to 9999)
128 shift registers
Supplied with comprehensive user manual
Starter Kit
Low-cost entry starter kit, complete with base unit, software, interface, cables and
manuals
MICRO-3
Supply Voltage 100 240V ac
Each 10 I/O, 16 I/O and 24 I/O unit can be configured as either a CPU base unit
26 Inputs
Outputs
Mounting
Volt-free contact or NPN transistor (source input)
Volt-free contacts rated 2A 240V (resistive)
35mm symmetric DIN rail or screw mounting
or an expansion unit
Built-in communications allow up to 6 slaves to be connected to a master using an
Indicators Red LEDs for power, run, error, each input and each output RS485 twisted pair network
Programmer 24 colour coded keys, run/stop switch, 16 character LCD. 32 PLCs can be networked to a central computer using the Micro3 networking
Industrial Computing & PLC's 870

Connected to PLC via lead supplied products


H W D Mftrs List No. Order Code Analogue input and output facility using the FC2A A/D and D/A units
Base unit 80 140 74 FC1A-C2A4E 179-950 Pulse output and high speed counter functions enable simple position control
Programmer 80 110 20 FC1A-HL1E 179-952 Real-time clock included (16 & 24 I/O versions only)
Interface WPCLA 710-2045 Built-in power supply
Programming cable KL-KC1 710-2057
Starter Kit FC1A-CLIP 710-2082
MICRO-3C
All the basic features of the Micro-3, plus many upgraded functions for
inc49 communications
ASCII or binary transmit/receive (via RS232 serial port)
Price Each
Attach a modem to provide remote communications
Order Code 1+ 5+ 10+
Advanced instructions for transmitting/receiving data with RS232 port
Base Unit 179-950 500 available data registers 32 for high speed processing
Programmer 179-952 Ideal for modems, printers, bar code readers, scales, as well as other interface and
Interface 710-2045 communications devices
Programming Cable 710-2057
Starter Kit 710-2082 Unit Inputs Outputs Dimensions
MICRO-3 (Sink or source) (RELAY) H W D Mftrs List No. Order Code
10 I/O 6 4 85 105 60 FC2A-C10A1 710-2173
16 I/O 9 7 85 135 60 FC2A-C16A1 710-2185
Analogue Timer Unit 24 I/O 14 10 85 165 60 FC2A-C24A1 710-2197
MICRO-3C
16 I/O 9 7 85 135 60 FC2A-C16A1C 722-3857
24 I/O 14 10 85 165 60 FC2A-C24A1C 722-3869
inc50

Price Each
Unit Order Code 1+ 3+ 5+ 10+ 20+
MICRO-3
10 I/O 710-2173
16I/O 710-2185
24I/O 710-2197
Expansion unit Micro expansion unit (3 O/P) Analogue timer unit MICRO-3C
Expansion of the Micro-1 is possible using either the expansion unit, a Micro 16I/O 722-3857
expansion unit, or an analogue timer unit 24I/O 722-3869
Only one expansion I/O or one micro expansion I/O or one analogue timer unit can
be used per Micro-1 CPU
CPU base unit provides power for expansion I/O Windows Based Programming Software
Expansion Units Programs all Idec Micro PLCs
Doubles Micro-1 I/O to 16 inputs and 12 outputs Runs on Windows 3.1, 3.11, 95 and NT
Micro Expansion Units Comes complete with tutorial
Used for incremental I/O expansion Drag and drop programming from Windows style toolbar
Options available: 2 source inputs & 2 sink outputs, 4 source inputs or 3 relay out- Multi-level undo commands
puts Print preview to display ladder (with mnemonics if desired)
Analogue Timer Unit Open multiple ladder files
Allows changing of timer values without the need to stop the machine Direct monitoring
4 separate time potentiometers, each with 8 different time ranges
Ranges from 0-1 sec through 0-10 Min.

870 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
inc185 4 20 character display
5 two colours LEDs
Price Each 5 function keys
Mftrs' List No. Order Code 1+ 3+ 5+ 10+ 20+ Alpha numeric keyboard capability
WINDLDR 722-4205 Real time clock
RS232 printer port
24V dc operating voltage
INC209

A/D and D/A Converters Price Each


Mftrs. List No. Order Code 1+ 5+ 10+
MAC E200 725-8422
MAC E200 Manual 725-8446
Accessories
Windows Based Software 774-595

E300
A/D units convert analogue input signals into digital signals for storage within an
internal CPU register The E300 is an HMI that has been designed to simpli-
D/A units convert a digital input value from an internal CPU register into an fy automation display problems. The E300 has a
analogue output range of features to suit most applications and with
Each A/D or D/A uses one input or one output of the PLC its simple programming and screen creation software
gives fast HMI usage in the shortest possible time.
Unit Dimensions
H W D Mftrs List No. Order Code
For software order part number 774-595, page 871
Input 0-10V 80 45 70 FC2A-AD2 710-2306
Input 4-20mA 80 45 70 FC2A-AD4 710-2318
Output 0-10V 80 45 70 FC2A-DA2 710-2320
Output 4-20mA 80 45 70 FC2A-DA4 710-2331
inc52
Real time trend graphs
Price Each Recipe handling
Unit Order Code 1+ 3+ 5+ 10+ 20+ Scrollable text blocks
Input 0-10V 710-2306 Alarm handler
Input 4-20mV 710-2318 Password protection - to device level
Output 0-10V 710-2320 Time channels
Output 4-20mA 710-2331 Connectivity to Mitsubishi and other manufacturers PLCs
Networking options, including Profibus DP
Windows drag and drop prgramming
Micro-3C Communications Cables 2 4 0 64 backlit LCD display
16 two colours LEDs
Modem cable (3m), connects basic unit (loader port) and modem (1:1 8 function blocks
communications) Alpha numeric keyboard capability
With D-sub 25-pin connector to connect to modem Real time clock
PC Interface cable (3m), connects basic unit (loader port) and PC (1:1) RS232 printer port for alarms and report generation inc227
communications)
With D-sub 9-pin female connector to connect to computer
PC Interface cable (2m), connects basic unit (data link terminal) and PC (1:1
Mftrs.
List No. Order Code 1+
Price Each
5+ 10+
26
communications) MAC E300 725-8434
With D-sub 9-pin female connector to connect to computer MAC E300 Manual 725-8458

Industrial Computing & PLC's 871


User Communication cable (2.4m), connects basic unit (loader port) and users
equipment
Without a connector to connect to RS232C equipment
inc184
E700/E710
Price Each
Typ Mftrs' List No. Order Code 1+ 3+ 5+ 10+
Modem (3m) FC2A-KM1C 722-3870
PC (3m) FC2A-KC4C 722-3882
PC (3m) FC2A-KC6C 722-3894
User Comms
(2.4m) FC2A-KP1C 722-3900

Operator Interfaces
The E700 and E710 are graphic based HMIs that are user-friendly both for operators
E100 and designers. With the object oriented programming software it is easy to create a
2 line x 20 character backlit LCD dis- RS232 printer port user interface that exactly answers the operators needs. E710 has touch screen. For
play Password protection software order part number 774-595, page 871
4 function keys Connectivity to Mitsubishi and other
Historical trend graphs
Real time clock manufacturers PLCs
Recipe handling
Recipe handler 5Vdc from PLC or external
Scrollable text blocks
Report generation IP65
inc265 Alarm handler
Password protection - to device level
Price Each Time channels
Mftrs. List No. Order Code 1+ 5+ Connectivity to Mitsubishi and other manufacturers PLCs
E100 309-2458 Networking options, (including Profibus DP)
Windows drag and drop programming
E700 E710
E200 Real time clock
RS232 printer port (for alarms and report generation)
The E200 is a compact, powerful Human Machine 24V dc operating voltage
Interface with an abundance of features at an 3 2 0 240 backlit 16 colour LCD display 320 240 backlit 16 colour LCD
affordable price. For software order part number LCD display display - touch screen
774-595, page 871. 14 two colour LEDs 8 two colour LEDs
16 function keys 8 function keys
Scrollable text blocks Alpha numeric keyboard capability inc228
Alarm handler
Password protection to device level Mftrs. Price Each
Time channels List No. Order Code 1+ 5+ 10+
Connectivity to Mitsubishi and other manufac- MAC E700 725-8460
turers PLCs MAC E710 725-8471
Windows drag and drop programming E700/710 Manual 725-8483

continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 871
Industrial Computing & PLC's
Operator Interfaces continued Operator Interface -NT2S

Magelis HMI Terminals Overview


The Magelis family of HMI terminals from Schneider Electric consists of a range of
units from simple text displays available for under 150, through to comprehensive
graphical terminals in either Keypad or Touch screen formats. Combining the strengths
of the Modicon and Telemecanique brands, these units are ideal partners for the
Modicon TSX range of PLCs, but the programming software also feature protocol dri-
vers for Allen Bradley, Omron, and Siemens PLCs.
INC249

Magelis Text Displays H=55, W=102, D=50

Displays with alphanumeric screens are used to represent variables and messages The NT2S operator interface is a low cost unit for use with all Omrom C series PLCs.
Various keys can be used to modify variables, control the device or browse in a dia-
Features include:
logue application
2 line, 32 character LCD display
Uni-Telway version is developed specifically for use with the Telemecanique PLC
6 function keys
protocol
Embedded variables and data entry possible
Other versions use the communication protocols within the software package,
IP65 NEMO 4 rated
Order Code 321-6056
8k EEPROM memory
Matrix display version can be used to display bitmap images and animated bar
chart and gauge objects Mftrs. List No. NT25-SF123B-4=305-5656 PLC201
Uni-Telway version is LCD, multiple protocol version has back-lit LCD
Price Each
Power Supply 24Vdc, multiple protocol version is 5V during operation
(from Nano/Micro PLC) Order Code 1+ 5+ 10+ 25+
No. Keys 5 service keys Non-programmable, 9Vdc 305-5656
Protection IP65 INC251
HMI - PLC cable - 2m 305-5668
HMI - PLC cable - 5m 305-5670
Price Each
20 x 20 characters Mftrs. List No. Order Code 1+ 5+ 10+
Uni-Telway XBTF011110 321-5994 Operator Interface - 'NT11S'
Multiple XBTH011010 321-6007 Features include
8 x 40 characters Flash memory - no need for batteries
Matrix Display XBTHM017010 321-6019 IP65 NEMA 4 - withstands water and oil
RS232 and RS422 ports as standard
Printer port
Magelis Graphical Displays Password screens for security
Keypad and Touchscreen Large keys for numeric data entry
Graphical display terminals available in either keypad or touchscreen formats Simple to use - simplifies ladder
Keypad version has 5.7" monochrome screen H=113, W=218, D=38.2 programming
Panel Cut-out 98 203 Long lived easy access
Touchscreen format has 5.7" or 10.4" colour screen
Specially designed for operator dialogue graphic functions Bar graph facility
Dynamic visualisation of operating data (setpoints, measurements, recipes, mes- UL & CSA approved CE marked

26
sages) and process errors
Scaling of analogue variables
The NT11S operator interface is a slim operator that stands up well to harsh enviro-
ments. A 4 line display that can accept embedded data and robust numeric and user
Alarm log and management of alarm groups definable function keypad makes the NT11S ideal for machine status and control
Three levels of password Realtime and trending curves
Supply voltage 24Vdc (-15% +10%) Operating temperature 0 to +50C
Industrial Computing & PLC's 872

IP65 protection 24Vdc supply


INC250 Power consumption 15W max. Max. number of registered screens 250

Price Each FOR SUITABLE SOFTWARE SEE ORDER CODE 201-455 PAGE 873
PLC40
Keypad Mftrs. List No. Order Code 1+ 5+ 10+
5.7 XBTF011110 321-6020 Price Each
Touchscreen Mftrs List No. Order Code 1+ 5+ 10+ 25+
5.7 XBTF032110 321-6032 Display NT11S-SF121 201-431
10.4 XBTF034110 321-6044

Magelis Software and Connection Cables Operator Interface - 'NT20S'


Touch Screen
The software is used with the whole range of Magelis terminals to create operator dia-
logue applications designed for controlling automated systems. All the applications
created using the software are independent of the protocol used; it is possible to use
the same operator dialogue application with all the different PLCs supported by the
connection options highlighted in the table below.
The software is used to easily create all the pages, such as alarm, help, recipe etc.
that are found in all applications
Used to configure the function keys to activate commands on the machine or call
application pages
In-built simulation facility H=110,
Supplied on CD-ROM, compatible with Windows 95 or NT4 W=190,
Software supplied with manual, connection cable and 25 way/9-way connection D=58
interface Panel Cut-out 100 178

Connection cables are used to connect the terminals to most of the major PLC brands Touch screen operator interface for use Lamps and touch switches
in the market. with all Omron PLCs Bargraphs
Note: Adaptor, Order Code 329-0311 must be used with Siemens cable, Order Code Features include: RS232 port for programming and PLC
321-6135. Flash memory - no need for batteries - HMI comms
INC252 Transparent communications - no User definded graphics available
Price Each interfacing software Alpha string handling
Up to 500 screens In-built thumbwheel data entry
Mftrs. List No. Order Code 1+ 5+ 10+
LCD display with 128 256 dot resolu- 1:1 and 1:n configurations supported
Software XBTF011110 321-6056 tion UL & CSA approved
Manual XBTH011010 321-6147 IP65 enclosure CE marked
Connection cable
Power supply 24DC (-15% +10%)
Modicon TSX XBTZ968 321-6068 Power consumption 10W max.
Allen Bradley - SLC500 XBTZ9730 321-6070 Operating temperature 0 to 50C
Allen Bradley - Micrologix XBTZ9731 321-6081 Meet standards EN61131-2 (MAC-D) (1984), EN50081-2(EMC-D) (1992)
Omron - CQM/CVM RS422 XBTZ9740 321-6093
Omron - CVM RS422 XBTZ9741 321-6100 FOR SUITABLE SOFTWARE SEE ORDER CODE 201-467 PAGE 873
PLC41
Siemens - S7-200 XBTZ9721 321-6111
Siemens - S7-CP525 XBTZ9720 321-6123 Order Price Each
Siemens - S5 AS511 Port XBTZ909 321-6135 Mftrs List No. Code 1+ 5+ 10+ 25+
Adaptor - use with 321-6135 XBTZ939 329-0311 Display NT20S-ST121-EV3 201-443

872 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Programming Software and Cables 320 240 5.7" monochrome or colour Ethernet port
For Omrons 'NT11S' and 'NT20S' Operator Interfaces LCD display with CCFL backlight Resistive touch
512K Flash, 128K RAM Win CE operating system
PC based programming package allows generation of screens for the Omron NT11S 2 serial ports RS232 and IP65 NEMA4
and NT20S. Screens can easily be designed with a mouse driven interface and PLC RS485/RS422 Password screens for security
data areas assigned to dynamic functions such as bar graphs, character strings, touch Parallel port User friendly configuration
switches and lamps very easily . User defined symbols can be accessed using the Real time clock Connectivity to IMO PLCs and others
"mark" facility. Full saving editing and copy function are available. RS232CABLE 16 programmable keys, 16 system Expansion capabilities
allows programming of the HMIs whilst the CABLE2 connector allows communication keys CE marked
between PLC and HMI 2 status, 10 dual col. programmable
PLC42 LEDs
Price Each Supply voltage: 9-35V dc Operating temperature: 0-50C
Mftrs List No. Order Code 1+ 5+ 10+ 25+ PLC229

NT11S Software NT11S-ZA3AT-EV1 201-455 Price Each


NT20S Software NT-EV2-SOFTWARE 201-467 Mftrs. List No. Description Order Code 1+ 5+ 10+
Prog. Cable RS232CABLE 199-965.
MI320MONOT-FAR monochrome 353-2781
PLC-HMI Cable CABLE2 201-479
MI320COLOURT-FAR colour 353-2793

Operator Interface 2 20 Character


& 4 20 Character Operator Interface 640 480 Touch

2 and 4 lines, 20 characters LCD dis- 2 status LEDs


play with LED backlight IP65 NEMA4
128K Flash, 32K RAM Password screens for security 640 480 9.5 colour LCD display Resistive touch
Single serial port, RS232 and User friendly windows configuration with CCFL backlight Win CE operating system
RS485/RS422 Connectivity to IMO PLCs and others 512K Flash, 128K RAM IP65 NEMA4
6 navigational keys CE marked 2 serial ports RS232 and Password screens for security
4 programmable keys RS485/RS422 User friendly configuration
Parallel port Connectivity to IMO PLCs and others
Supply voltage: 9-35V dc Operating temperature: 0-50C Real time clock Expansion capabilities
PLC230
Ethernet port CE marked
Prices Each 2 status LEDs
Mftrs. Part No. Order Code 1+ 5+ 10+ Supply voltage: 9-35V dc Operating temperature: 0-50C
MI2L20C-FAR
MI4L20C-FAR
353-2732
353-2744 Prices Each
PLC228
26
Mftrs. Part No. Order Code 1+ 5+ 10+

Industrial Computing & PLC's 873


MI9.5COLOURT-FAR 353-2800
Operator Interface 4 20, 4 40
& 8 40 Character
Operator Interface
PMU200

4 and 8 lines, 20 and 40 characters 2 status, 10 dual col. programmable Ideal for replacing conventional panel designs using lamps, mimics and pushbuttons.
LCD display with LED backlight LEDs Features include:
128K Flash, 32K RAM IP65 NEMA4 Mono black & white or mono blue LCD options
2 serial ports RS232 and Password screens for security 240 128 pixel 4.2" graphic display
RS485/RS422 User friendly windows configuration 128k flash EPROM memory
Parallel port Connectivity to IMO PLCs and others 16 programmable function keys
Real time clock Expansion capabilities 1 input, 2 outputs
16 programmable keys, CE marked 24V dc supply
16 system keys Drivers for IMO PLCs plus other manufacturers
Supply voltage: 9-35V dc Operating temperature: 0-50C Integral RS232 port
PLC231 PMU screen configuration software provided
Prices Each PMU-200BN-FAR 327-8827 PMO-200S-FAR 327-8852
Mftrs. Part No. Order Code 1+ 5+ 10+ PMU-200LN-FAR 327-8839
INC279
MI4L20CX-FAR 353-2756
MI4L40CX-FAR 353-2768 Price Each
MI8L40CX-FAR 353-2770 Order Code 1+ 5+ 10+ 25+
Blue LCD 327-8827
Operator Interface - 320 240 Monotouch Black & White LCD 327-8839
RS485 Serial Interface 327-8852
or Colourtouch
continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 873
Industrial Computing & PLC's
inc64
Operator Interfaces continued
Mftrs. Price Each
Operating Interface List No. Order Code 1+ 5+ 10+ 15+ 20+
PMU300 CL10 711-0789
CL15 711-0790
CL20 711-0807

Operator Interface Terminals


Compatible with most PLCs
Over 60 serial communications proto-
cols
Ideal for replacing conventional panel designs using lamps, mimics and pushbuttons. Full dial-in/dial-out modem support
Features include:- Powerful 500 pint alarm scanner
Mono black and white or mono blue LCD options Comprehensive trending package
320 240 pixel 5.7" graphic display Terminals can be networked for factory
Touch screen display wide data collection
256k flash EPROM memory Displays are CCFL liquid crystal. Both units
16 programmable function keys have RS232 and RS485 ports and are
4 inputs, 11 outputs sealed to IP65 from the front panel
24V dc supply
Drivers for IMO PLCs plus other manufacturers Display Size (Pixels) 2 5 6 128 256 128
PMU screen configuration software provided H 162 199
L 206 224
D 67 67
PMU-300BT-FAR 327-8918 PMO-300S-FAR 327-8931 Soft Keys 4 4
PMU-300LT-FAR 327-8920 Function Keys - 12
inc278 Numeric Keyboard no yes
Real-Time Clock yes yes
Order Price Each Power Supply 10-40V dc 24V ac
Code 1+ 5+ 10+ 25+ Mftrs. List No. GL300 GL350
Order Code 711-2117 711-2129
Blue LCD 327-8918 inc65
Black & White LCD 327-8920
RS232/RS485 Serial Interface 327-8931 Mftrs. Price Each
List No. Order Code 1+ 5+ 10+ 15+ 20+
GL300 711-2117
Operator Interface GL350 711-2129
PMU600
Ideal for replacing conventional
panel designs using lamps, Operator Terminal Software and Converter
mimics and pushbuttons. Powerfull and easy-to-use package
Features include:-
26 Offers: trending, 500 point alarm scan-
ner, networking, real time analysis and
event logging
EL-mono, EL-Colour
and TFT-LCD 16 colour Includes a comprehensive reporting
640 480 pixels (VGA) feature
Industrial Computing & PLC's 874

10.4 inch display Comes with program cable and a com-


Touch screen display prehensive manual
512k flash EPROM memory Communications converter in conve-
12 programmable function keys nient DIN rail package for simple con-
4 inputs, 11 outputs version from RS232 to RS485
Printer port
110/240 Vac supply
inc66
PMU screen configuration software provided
PMU-600TT-FAR 327-8943 PMU-600ET-FAR 327-8967 Mftrs. Price Each
PMU-600CT-FAR 327-8955 PMO-600S 327-8979 List No. Order Code 1+ 5+ 10+ 15+ 20+
inc276 Converter PDOCM000 711-8260
Software PDSF0000 711-2294
Order Price Each
Code 1+ 5+ 10+ 25+
TFT 16 Colour 327-8943
Luminescence 8 Colour 327-8955
Fieldbus
Luminescence Mono 327-8967 Flex I/O System
RS232/RS485 Serial Interface 327-8979
Flex I/O I/O Modules
Flex I/O Digital Modules
Operator Interface Terminals Inputs: DC 10-30V dc rated
Compatible with most PLCs Outputs: Relay Volt free 2.A @, 5-265V
Over 60 serial communications proto- ac, 2A @ 24V dc
DC Transistor 20.4 26.4V dc, 0.5A
cols
Full dial-in/dial-out modem support
Powerful 500 pint alarm scanner
Comprehensive real time trending A-B Part Number Input Type No. Inputs No. Outputs Order Code
package 1794-IB16 DC 16 - 351-5928
Terminals can be networked for factory 1794-OB16 DC - 16 351-5930
wide data collection 1794-OW8 DC - 8 relay 351-5941
Flex I/O Analogue Modules
Module Type Specification
Displays are backlit LCD all units have RS232 and RS485 ports and are sealed to IP65 Input 0-10V, +/-10V, 0-20ma, 4-20ma, 12 bit resolution (11 bit bipolar)
from the front panel Single ended inputs
Output 0-10V, +/-10V, 0-20ma, 4-20ma, 12 bit resolution
Display Size (Pixels) 2 20 2 40 2 20
Single ended Outputs
H 162 106 66
L 206 285 206 A-B Part Number No. Inputs No. Outputs Order Code
D 66 106 66
Soft Keys 3 5 3 1794-IE8 8 - 351-5953
Function Keys 8 - 8 1794-OE4 - 4 351-5965
Numeric Keyboard yes no yes
Real-Time Clock yes yes yes
Power Supply 24V dc 24V dc 24V dc
Mftrs. List No. CL10 CL15 CL20
Order Code 711-0789 711-0790 711-0807

874 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
PLC204 Terminal Bases
Price Each A-B Part Number Terminal Style Order Code
Mftrs. List No. Order Code 1+ 3+ 5+ 1734-TB Screw 351-6519
1734-TBS Spring Clamp 351-6520
1794-IB16 351-5928
1794-OB16 351-5930 Communications Adapters
Order Code
1794-OW8 351-5941
1794-IE8 351-5953 1734-ADN Full DeviceNet Adapter supports 63 I/O modules 351-6544
1734-PDN DeviceNet Interface, supports 12 I/O Modules,
1794-OE4 351-5965 each module is a DeviceNet node 351-6532
Accessories
Order Code
Flex I/O System 1734-FPD Field Potential Distributor, used to create new AC, DC or Analogue
Communications Adapters Power buses. For use with 1734-PDN 351-6556
1734-EP24DC Field Potential Distributor, used to create new AC, DC or Analogue
Supports up to 8 Modules Power buses. For use with 1734-ADN 351-6313
Requires 24V dc Power
Diagnostics for communi- The voltage distribution modules provide two important functions. Partitioning and bus
cations extension.
Partitioning is divided into logical and functional partitioning:
1. Functional partitioning means grouping together modules of similar signal types that
perform specific functions such as sequential control, axis or motion control, or
process control.
2. Logical partitioning is dividing groups by I/O type thereby separating analogue and
PLC205
digital signal power sources. Digital signals may be divided into AC and DC.
Mftrs. Price Each Field Potential Distributor
List No. Description Order Code 1+ 3+ 5+
The field potential distributor allows you to convert your field power so that you may
1794-ASB Remote I/O 333-8332 have a broad range of voltage inputs in your 12-module system. This range of voltage
1794-ADN DeviceNet 351-5916 inputs includes 5V dc to 240V dc and/or 5V ac to 264V ac applications and I/O
modules.
PLC218

Terminal Base, 3 Wire Price Each


Mftrs. List No. Order Code 1+ 3+ 5+
Terminal base for I/O modules
Mounted horizontally or vertically 1734-IB2 351-6465
Mounts on a DIN rail 1734-IB4 351-6477
Keyed to prevent modules being 1734-OB2E 351-6489
incorrectly positioned 1734-OB4E 351-6490
1734-OW2 351-6507
1794-IE2C 351-6441
1794-OE2C 351-6453
1734-TB 351-6519
1734-TBS 351-6520
INC154
1734-ADN 351-6544
Price Each 1734-PDN
1734-FPD
351-6532
351-6556
26
Mftrs. List No. Order Code 1+ 3+ 5+
1734-EP24DC 351-6313
1794-TB3 333-8812

Industrial Computing & PLC's 875


ArmorBlock LP2 System
Point I/O System

Point I/O is a family of modular input and output modules that highlight ease of use,
effeciency, ergonomics and economics. The Point I/O system is ideal for applications
where flexibility and low cost of ownership are key for successful control system ArmorBlock LP2 is an IP67 packaged I/O product designed for use in harsh manufac-
design. turing environments. These blocks require no enclosure and can be mounted directly to
Colour coded components for easy maintenance machinery or equipment where sensors or actuators are placed. The ArmorBlock LP2
Removable I/O cards and terminal strips products have DeviceNet built-in and connect directly to a DeviceNet network.
Small, modular design Autobaud detection eliminates potential for incorrect baud rate problems
System, node and point level diagnostic feedback via LEDs Electronically protected outputs automatically protects outputs from over current
Just what you need I/O and short-circuit conditions
Select the I/O modules that you need from the list below, (each module requires a Hardware Watchdog circuitry puts outputs in known state if internal failure occurs
base, see terminal bases). Finally, choose the communications adapter from the sec- IP67 Rated -25C to 60C operation 1200Psi Washdown
tion below. ArmorBlock LP2 I/O Digital Modules
Point I/O Digital Modules Inputs: DC 10-30V dc rated Outputs: DC Transistor 10-30V dc, 300m
Inputs: DC 10-29V dc rated Outputs: Relay Volt free 2.A @ 5-265V ac, No. of 12mm
2A @ 24V dc A-B Part Number No. Inputs No. Outputs Connectors Order Code
DC Transistor 10-29 V dc, 1A
1792D-2B2LP 2 2 4 351-5850
A-B Part Number Input Type No. Inputs No. Outputs Order Code 1792D-4B0LP 4 - 4 351-5862
1792D-4BT4LP 4 4 4 351-5874
1734-IB2 DC 2 351-6465
1792D-16BT0LP 16 8 351-5886
1734-IB4 DC 4 351-6477
1792D-0BT16LP - 16 8 351-5898
1734-OB2E 2 transistor 351-6489 PLC219
1734-OB4E 4 transistor 351-6490
1734-OW2 2 relay 351-6507 Price Each
Analogue Modules Mftrs. List No. Order Code 1+ 3+ 5+
1792D-2B2LP 351-5850
Module Type Specification A-B Part No. No.
Number Inputs Outputs Order Code
1792D-4B0LP 351-5862
Input 0-20ma, 4-20ma, 16 bit resolution 1792D-4BT4LP 351-5874
Single ended Inputs 1794-IE2C 2 351-6441
1794-OE2C 2 351-6453
1792D-16BT0LP 351-5886
Output 0-20ma, 4-20ma, 16 bit resolution 1792D-0BT16LP 351-5898
Single-ended Outputs
continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 875
Industrial Computing & PLC's
The InterBus S remote bus cables are for connecting host controller boards for PLC's
Fieldbus continued computers, Bus terminals and input/output modules. Remote installation Bus cable
Dioplex FieldBus I/O Modules,
R
incorporates 3 additional conductors for the supply of modules and connected sen-
sors/actuators. This cable is required when using the IP67 I/O modules featured in the
IP67
catalogue. This cable is also suitable for continuous flexing applications as encoun-
tered in C tracks.
ProfiBus Cable
The ProfiBus cable is suitable for connecting host controllers to Bus connected devices

DeviceNet Cable
The Belden DeviceNet cables are suitable for DeviceNet trunk and drop connections

Outer Out /Km Mftrs. Order


Cable Type Construction Jacket Mfr. List No. Code
Modules allow direct connection of standard InterBus S Remote Install. Bus PUR 8.6 159.8 Lutze 104209 720-6756
sensors and actuators to Profibus DP, Cable
( 3 2 0.25+3 1)
DeviceNet and Interbus S InterBus S Remote Bus Cable PVC 6.5 159.9 Lutze 104200 720-6744
High ingress protection to IP67 level, enables ( 3 2 0.25)
the most rugged operating environments ProfiBus ProfiBus Cable PVC 8 62.4 Lutze 104214 720-6758
Modules use industry standard M12 connec- ( 1 2 0.64)
tions for inputs and outputs enabling fast sen- DeviceNet DeviceNet
sor/actuator connection Trunk Cable PVC 12.2 22.7 Belden 3082A 720-6811
To obtain >8 inputs/outputs per FieldBus mod- DeviceNet DeviceNet Drop Cable PVC 7 90.9 Belden 3084A 720-6823
ule, M12 splitters are required allow 2 sen- inc179
Dioplex IP67 FieldBus modules sors/actuators to be connected to one connec-
H=168, D=47.5 tor 1m Per Length Mftrs. Price Each
FieldBus modules connect onto network using either 6, 9 or 12 pin FieldBus con- List No. Order Code 1+ 10+ 20+
nectors InterBus S Remote
For Interbus S, a Bus Terminal Module is required when connecting to a remote- Installation Bus 104209 720-6756
bus. This requires a 24V supply which is connected using a 6 pin FieldBus connec- 1+ 10+ 50+
tor InterBus Remote 104200 720-6744
ProfilBus 104214 720-6768
The use of Dioplex FieldBus modules enables a considerable reduction in cabling
DeviceNet Trunk 3082A 720-6811
associated with installing sensors and actuators in control systems.
DeviceNet Drop 3084A 720-6823
Qty M12 Trans- Trans-
Channels Splitters Current mission mission Order
Bus I/P O/P Required I/P O/P Medium Rate Code Bus Markers
DeviceNet 16 8 8mA 5-wire cab 500 kbaud 708-4206
DeviceNet app Max
DeviceNet 8 8 8 6mA 2A 5-wire cab 500kbaud 708-4432
DeviceNet app

26 InterBus S

InterBus S
8

8
6mA

6mA
Remote
BusTerminal
Remote
As Interbus
S DIN 19258
As Interbus
708-5710

708-5795
Installation Bus S DIN 19258
InterBus S 8 4 4 6mA 2A Remote As Interbus 708-5801
Industrial Computing & PLC's 876

Installation Bus SDIN 19258


ProfiBus DP 16 8 8mA ProfiBus 12MHz 708-6120
App cable Max
ProfiBus DP 8 8 8 6mA 2A ProifBus 12MHz 708-6570
App cable Max Marker tabs for signal and connection identification
Operating Temperature 0-60C 100 marker tabs per pack
Used with Beckhoff bus terminals
FieldBus Connectors Required Per Module inc162
DeviceNet Modules 1 x 6 pin
InterBus S Remote Bus Terminal 2 x 9 pin plug 100 Per Pack Mftrs. Price Per Pack
1 x 9 pin socket List No. Order Code 1+ 5+ 10+ 25+
1 x 6 pin for 24V
Blank BZ1000 718-2533
InterBus S Module 1 x 9 pin plug
Ov BZ1100 718-2545
1 x 9 pin sockets
- BZ1102 718-2557
ProfiBus DP Module 1 x 12 pin
24V BZ1104 718-2569
inc10 + BZ1106 718-2570
pe BZ1108 718-2582
Price Each 00 01 - 48 49 BZ1400 718-2594
Bus Type Order Code 1+ 3+ 5+ 10+ 50 51 - 98 99 BZ1405 718-2600
DeviceNet 16 I/P 708-4286 100 101 - 148 149 BZ1410 718-2612
DeviceNet 8 I/P 150 151 - 198 199 BZ1415 718-2624
4 O/P 708-4432 200 201 - 248 249 BZ1420 718-2636
InterBus S 8 I/P 250 251 - 298 299 BZ1425 718-2648
Bus Terminal 708-5710 300 301 - 348 349 BZ1430 718-2650
InterBus S 8 I/P 708-5795 350 351 - 398 399 BZ1435 718-2661
InterBus S 8 I/P 400 401 - 448 449 BZ1440 718-2673
4 O/P 708-5801 450 451 - 498 499 BZ1445 718-2685
ProfBus DP 16 I/P 708-6120 500 501 - 548 549 BZ1450 718-2697
ProfBus DP 8 I/P 550 551 - 598 599 BZ1455 718-2703
4 O/P 708-6570 600 601 - 648 649 BZ1460 718-2715
M12 Splitter 720-6720 650 651 - 698 699 BZ1465 718-2727
700 701 - 748 749 BZ1470 718-2739
750 751 - 798 799 BZ1475 718-2740
FieldBus Cable
R
800 801 - 848 849 BZ1480 718-2752
850 851 - 898 899 BZ1485 718-2764
IP67
900 901 - 948 949 BZ1490 718-2776
950 951 - 998 999 BZ1495 718-2922

InterBus S Cable

876 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
RS232C 'D' Kits - 25 Way Connectors for Dioplex I/O Modules
R

Free connector kits with primary pole posi- ProfiBus


tions loaded with pins or sockets. The pole 12 pin connector for connecting Dioplex IP67
positions that are loaded are those most FieldBus modules to ProfiBus DP networks
commonly used by TS232C and V24 inter-
faces InterBus

9 pin plug and socket connectors for connecting


Dioplex IP67 FieldBus modules to InterBus S net-
works
DeviceNet
Pins loaded are: Mftrs. List No. 6 pin connector for connecting Dioplex IP67 I/O modules to DeviceNet networks
1. Earth 4. Request to send 7. Signal ground 256-25T-A003
2. Transmit 5. Ready to send 8. Data carrier detect 256-25T-A004 FieldBus connectors maintain the IP67 integrity of cable connection when using Lutze
3. Receive 6. Data set ready 20. Data terminal ready Dioplex I/O modules
inc166
FieldBus/ Plug Mftrs. Order
Dioplex I/O unit Pins Socket List No. Code
Price Each
ProfiBus 12 RC12PIN128049 720-6719
Order Code 1+ 25+ 50+ 100+ 250+ InterBus S 9 RC09PIN129049 720-6689
Free plug 315-862 InterBus S 9 Plug RC09SIN128049 720-6690
Free socket 315-874 Power I/P for InterBus terminal
module 6 Socket RC06SIN121600 720-6707
DeviceNet 6 RC06SIN121600 720-6707
inc177
'D' connectors, EMI/RFI Shielded
Solda 'D' Tin and Dimple (formed Pin) Price Each
Connector Order Code 1+ 3+ 5+ 10+ 20+
A range of tin and dimple D connectors offering excellent EMI/RFI screening via shell
12 Pin 720-6719
continuity dimples. The connectors are available in solder bucket and right angle PCB
9 Pin Plug 720-6689
options. The pins and sockets are formed contact style.
9 Pin Socket 720-6690
Contact Rating 3A 60C Housing Steel, tin plating 6 Pin 720-6707
Contact Resistance 20mWMax. Insulator Monobloc polyester, UL94V-0
Working Voltage 350V dc/ac peak Contacts Formed copper alloy, gold plating
Temperature Range 55C to +125C
Mating Cycles 100
inc167
AS-I
Price Each AS-i Master Controller
No. of Ways Order Code 1+ 25+ 100+ 250+ 500+ Standalone control function
Solder Bucket Plugs DIN rail mounted control module
9 105-505 Cost savings (no additional PLC
15 105-506 required)
25 105-507 Up to 124 I/O possible
37 105-508
Solder Bucket Sockets
Programmed via RS232 connection
(PC software supplied) 26
9 105-509
15 105-510 .

Industrial Computing & PLC's 877


25 105-511
37 105-512
90C PCB Plugs
9 105-612
15 105-613
AS-i standalone controller module. This DIN rail mounted module is used to control
25 105-614
simple AS-i networks, removing the need for an additional PLC. The controller can be
37 105-615
programmed with industrial standard STEP 5 language. The unit incorporates multiple
90C PCB Sockets timers, counters and flags which can enable complex control programs to be written
9 105-616 and executed. The controller can accommodate up to 31 separate AS-i nodes and
15 105-617 when used with the relevant As-i modules, 124 I/O can be achieved
25 105-618
inc1
37 105-619
Price Each
Mftrs. List No. Order Code 1+ 3+ 5+ 10+ 20+
D Shell, Metalised Plastic
VAM-CTR-KF-R2 707-4750
Straight and 45 Cable Entry

AS-i Profibus Gateway


As-i gateway for use with ProfiBus
Incorporates fault diagnosis and pro-
gramming features
Multidrop capability
DIN rail mounted
ABS with nickel over copper plating
EM/RFC shielding braid/foil folded back over suitable size strain relief bush
Range of 5 strain relief bushes per hood
Accepts foil, lap or braided cable
No tooling required for shield termination
Shell H H W D Cable Entry
Dimensions Straight 45 Both Both Via 5 bushes
9 way 35.5 37.2 31.1 16.3 5-7.5
15 way 38.8 40.6 39.1 16.3 5-8 inc2
25 way 42.0 44.1 53.1 18.0 5-8
37 way 46.5 45.7 69.3 23.0 8-15 Price Each
Mftrs. List No. Order Code 1+ 3+ 5+ 10+ 20+
inc168
VAG-PB-K5-R4 707-4773
No.of Price Each
Ways Order Code Order Code 1+ 10+ 50+ 100+ continued
9 746-058 746-060
15 746-071 746-083
25 746-095 746-101
37 746-113 746-125

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 877
Industrial Computing & PLC's
Micro PLC with integral AS-interface master, commands and controls all AS-inter-
AS-I continued face protocol functions
Built-in decoupling circuit for AS-interface power supply unit
AS-i InterBus-S Gateway 5 I/O, 3 inputs 24V dc (one high speed 3.5khz) and 2 independent outputs
Used with the InterBus S Bus coupler, 2A/250Vac or 0.5A/24V dc
the AS-i gateway provides a connec- Up to 124 binary switching I/O devices via AS-interface
tion to InterBus-S 64 timers, 32 counters, 512 (Max.) internal logic relays
Up to 8 InterBus gateways can be con- 1100 step EEPROM programme memory
nected to each bus coupler Programmed in relay ladder, function chart or word based logic using RPX C3
Ideal for complex systems where the WindowsT-based software
high speed communication capabilities Lithium battery available for real-time clock applications
of InterBus-S are of prime importance Conforms to LV and EMC directives
Incorporates fault diagnosis and pro-
Mftrs. List No. Order Code
gramming features Micro Controller with AS-i 7388175 710-4455
Multidrop capability 230V ac to 24V dc power supply 88758903 710-4479
DIN rail mounted Lithium Battery for real-time clock 8875305 710-4698
inc61

Price Each
Order Code 1+ 3+ 5+ 10+
inc3
Micro Controller with AS-i 710-4455
Price Each Power Supply 710-4479
Mftrs. List No. Order Code 1+ 3+ 5+ 10+ 20+ Lithium Battery 710-4698
As-i to Inter-Bus
S Gateway VAG-IBS-K1 704-4586
InterBus S Software and Cable
Bus Coupler VSV-ST24BKT 720-6884

AS-i DeviceNet Gateway


As-i gateway for connection to
DeviceNet
DeviceNet allows multi-dropping of up
to 63 VAG-DN-K5 gateways
Incorporates fault diagnosis and pro-
gramming features
Compact modular DIN rail mounted
housing
EDS file software included MS Windows compatible
Multidrop capability Comprises diskette, dongle, mouse mat and connection cable to PLC
Program editor
Project management and design

26

Application uploading and downloading
Program testing using real-time graphic animation
inc4
Lithium battery available for real-time clock applications
Conforms to LV and EMC directives
Mftrs. Price Each
Industrial Computing & PLC's 878

Mftrs. List No. Order Code


List No. Order Code 1+ 3+ 5+ 10+ 20+ Software, Cable & Access 7388181 710-4674
VAG-DN-K5 704-4598 inc62

Price Each
Order Code 1+ 3+ 5+ 10+
AS-i Power Supply 2,5A; 30Vdc
Software, Cable & Access. 710-4674
Designed for use with the ASi-system
Dual voltage input, either 115V ac or 230 V ac
30V dc-2.5A output incorporates decoupling
circuit to allow AS-i communication to operate
AS-i Hand Held Address Programmer
DIN rail mounted Compact hand-held unit for use with a whole range of
AS-i modules and sensors
Allows easy address programming of the AS-i
devices
Simple operation
Battery operation allows flexible on-site operation

inc8

Price Each
Type Order Code 1+ 3+ 5+ 10+
VAN-115/
230AC-K6 707-6885

inc9
PLC with Integral AS-i Master
Mftrs. Price Each
List No. Order Code 1+ 3+ 5+ 10+ 20+
VAP-HH1 707-7038

AS-i Network and Power Cable, Self-Sealing


AS-interface
flat cable for use with flat cable base
modules
Yellow = As-i data cable
Black = As-i power cable
1 metre lengths
Power supply unit
Micro PLC with AS-interface

878 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
inc38
AS-i User Input/Output Interface Modules
1m Length Price Each AS-interface input/output user mod-
Mftrs. List No. Order Code 1+ 10+ 20+ 50+ 100+ ules with terminals for sensor inputs
AS-i CABLE-YELLOW 709-1333 and actuator outputs
AS-i CABLE-BLACK 709-1345 . 4 Output, 4 Input, or 2 O/P and 2 I/P modules
available
Fits onto base modules, see Order Code
708-9090 or 708-9107
AS-i I/O Modules IP20 Sensors are attached using M12 connectors
Actuator switching up to 2A
Sensor operating energy up to 200mA
As-i I/O modules
H-27, W=45, D=80
Integrated diagnostic LED for switching status
Semiconductor versions with watchdog function
Supplied complete with name plates, screws and seals
Certified by the AS-interface association
Protection Class IP67
inc34

Price Each
Mftrs. List No. Order Code 1+ 3+ 5+ 10+ 20+
4 O/P ASIAM07FAAAA 708-8954
IP20 AS-I slave modules
4 I/P ASIAM06EEEE 708-8966
For connection to 1 to 4 standard sensors and actuators
2 O/P,
DIN rail mounting
2 I/P ASIAM08FEAA 708-8978
Accepts 2-wire round or flat (1.5mm2 or 2.5mm2)
LED indication of input and output status
Versions Description Mftrs. List No. Order Code
4 inputs 2 2 wire and 2 3 wire, 24V dc 88755401 710-6348 AS-i Base Modules for Flat and Round Cables
4 outputs 4 normally-open relay outputs 73880179 710-6361
2 I/P & 2 O/P 2 24V dc inputs (3-wire), 2 normally
open relay outputs 88755404 710-6373

inc63

Price Each
Order Code 1+ 3+ 5+ 10+ 20+
4 I/P 710-6348
4 O/P 710-6361
2 I/P & 2 O/P 710-6373
AS-interface base modules for connection to either flat or round bus line
4 Penetration technology provides reliable connection to flat cable
AS-i Flat Pack I/O Interface Modules Screw terminal technology for reliable connection to round cable

4 inputs for 2 or 3 wire sensors or


switch contact



Polarity reversal protection
DIN rail or screw mounting
Supplied complete with insert nuts, cable glands, seals and screws as required
26
Slim module design Certified by the AS-interface association
For use with AS-i flat cable for quick Protection class to IP67

Industrial Computing & PLC's 879


connection
Constructed from tough plastic Mftrs. List No. Order Code H W D
IP67 protection Base for flat bus cable ASIFKKV 708-9090 20 45 80
Base for round bus cable ASIPGK423 708-9107 33 45 80
inc35

Price Each
Range of AS-i input and output modules in flat style housing. AS-i connection made Order Code 1+ 3+ 5+ 10+ 20+
via AS-i flat cable. Inputs made via M12 connectors. Inputs suitable for 2-wire or 3-
Base for flat bus cable 708-9090
wire PNP sensors or switch contacts. LED indications for inputs and outputs and
Base for round bus
power supply. Solid state outputs powered via separate power supply connection.
cable 708-9107
inc40

Mftrs. Price Each


List No. Order Code 1+ 3+ 5+ 10+ AS-i Clamp-On Single Input Module
4 I/P VAA-4E-G3F-ZE 709-3615 Direct connection of devices with AS-interface
2 I/P, capability to Flat Bus cable
2 O/P VAA-2AE-G3FF-ZE/E2 709-3640 4 Penetration technology facility for ease of
4 I/P, installation to flat cable
4 O/P VAA-4EA-G3FF/ZE/E2 709-3652 Sensors attached using M12 connectors
Integrated sealing
Screw mounting possible
Protection class IP67
4-Way Input Unit With Lead Monitor PUR cable, 1M long
Allows connection of 4 standard dc sensors Mftrs. List No. Order Code
to AS-i network, providing lead breakage and Clamp-on connector ASIFKM12 708-9168
short circuit monitoring Clamp-on lead ASIFKRK/EF4212PUR 034 708-9170
Standard M12 connection (sensors) Clamp-on lead and connector ASIFKRK/EWF4212 PUR 034 709-0237
Round or flat cable versions inc36
LED indicators for inputs and fault conditions
aid system setup and fault diagnosis Price Each
Order Code 1+ 3+ 5+ 10+ 20+
Clamp-on connector 708-9168
inc42 Clamp-on with lead 708-9170
Clamp-on with lead
Mftrs. Price Each
+ connector 709-0237
Cable List No. Order Code 1+ 3+ 5+ 10+ 20+
Round VAA-4E-G1P-Z 709-5636 continued
Flat VAA-4E-G1F-Z 709-5624

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 879
Industrial Computing & PLC's
AS-I continued AS-i Photoelectric Sensors
AS-i Modules Accessories

Empty modules can be used for integration of customer-specific PCBs into the
standard AS-i housing Direct detection (diffuse) and retro-reflective photoelectric sensors
Module lid can be used with either round or flat cable AS-i base units to construct Sensing distances from 300mm for the compact F3 style sensors, up to 10m for
AS-i network junction boxes the larger 'block' style
Protection class IP67 Sensing ranges can be adjusted
Mftrs. List No. Order Code Ingress protection to IP66
Empty Module ASIAM00XXXXP 708-9181 Nominal
Lid ASIDK 708-9193 inc37 Sensing Sensor Includes Dimensions
Range mm Type Reflector H W D Mftrs. List No. Order Code
Price Each 500 Direct Detection n/a 30 30 91 OCT500-M1A-B3 706-5760
Order Code 1+ 3+ 5+ 10+ 20+ 3000 Retro-Reflective no 30 30 91 OCS3000-M1A-B3 706-6892
Empty Module 708-9181 800 Direct Detection n/a 64 25 75 OCT800-F8-B3 706-6909
5000 Retro-Reflective yes 64 25 75 OCS5000-F8-B3 706-6910
Lid 708-9193
2000 Direct Detection n/a 40 40 118 OCT2000-U9A-3 706-6922
10000 Retro-Reflective no 40 40 OCS10M-U9A-B3 706-6934
inc7
AS-i Inductive Sensors - Cylindrical
Price Each
Order Code 1+ 3+ 5+ 10+ 20+
706-5760
706-6892
706-6909
706-6910
706-6922
706-6934

AS-i Cable to Round Cable


26 Cylindrical Sensors
Inductive AS-i sensors with 15mm to 40mm sensing ranges
Sensors feature 2-part, plug-in construction to enable access to terminals for easy
connection
Industrial Computing & PLC's 880

Robust connection
Ingress protection to IP67
Industrial Block Type Sensors
Inductive AS-i sensors with 2mm to 15mm sensing ranges
Cylindrical stainless steel threaded bodies Compact connector allowing simple connection between AS-i flat cable and stan-
Housing diameters range from 12mm to 30mm dard, round, 2-core cable
M12 connection Connector simply clips over AS-i flat cable to make a reliable connection
Tough stainless steel housings
inc41
Ingress protected to IP67
Mftrs. Price Each
Cyndrical List No. Order Code 1+ 3+ 5+ 10+ 20+
Nominal Sensing Thread Dimensions
Range mm L Mftrs. List No. Order Code VAZ-T1-G2F 706-5760
2 12 60 NCB2-12GM60.B3-V1 705-0630
4 12 60 NCN4-12GM60.B3-V1 705-5146
5 18 60 NCB5-18GM60.B3-V1 705-6400 M8 and M12 Self-Assembly
8 18 60 NCN8-18GM60.B3-V1 705-6679
10 30 80 NCB10-30GM80.B3-V1 705-6760
15 30 80 NCN15-30GM80.B3-V1 705-6771
Block Type
Nominal Sensing Flush Mountable Dimensions
Range mm in metal H W D Mftrs. List No. Order Code
15 no 30 30 91 NCN15-M1A-B3 705-8913
15 yes 40 40 118 NCB15-U9A-B3 705-8925
20 no 40 40 118 NCN20-U9A-B3 705-8937
30 no 40 40 118 NCN30-U9A-B3 705-8949 Self-assembly
40 no 55 55 128 NCN40-U9A-B3 705-9206 Standard interface IEC 947-5-2
inc5 Protection class IP67
M8 version requires no special tools-innovative insertion technology
Nominal Positive-screw lock nut
Sensing Range Price Each
Moulded cable versions available in Sensors Section Circular connectors for con-
mm Cylindrical Order Code 1+ 3+ 5+ 10+ 20+ nection to AS-interface modules and sensor devices. Available in 8mm or 12mm
2mm 705-0630 diameters.
4mm 705-5146 Mftrs. List No.
5mm 705-6400
8mm Female Straight ELKA4008V 933367100
8mm 705-6679 8mm Male Straight ELST4008V 933407100
10mm 705-6760 12mm Male Straight ELST4012PG9 933162100
15mm 705-6771 12mm Female Right angle ELWIKA4012PG9 933174100 inc39
Block Type
15mm 705-8913 Price Each
15mm Flush 705-8925 Order Code 1+ 10+ 50+ 50+ 100+
Mountable 8mm Female Straight 709-1450
20mm 705-8937 8mm Male Straight 709-1461
30mm 705-8949 . 12mm Male Straight 709-1473
40mm 705-9206 12mm Female Right angle 709-1485

880 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
G4PB8 8 position I/O rack, barrier termination for field,
Single Channel I/O Modules 50 way IDC for control 7219088
G4PB16 16 position I/O rack, barrier termination for field,
G4 Digital I/O OPTO22 50 way IDC for control 7219090
G4PB16I 16 position I/O rack, barrier termination
for field and control, supporting both
negative and positive true output module configurations 7219106
G4PB16T 16 position I/O rack, barrier termination for field and control 7219118
G4PB24 24 position I/O rack, barrier termination for field,
50 way IDC for control 7219120
Ancillaries
G4 I/O mounted in a 16 way rack with G4STRAP, G4SWIN Switch module input simulator 7219180
8 way I/O rack for PC connection G4SWOUT Switch module output simulator 7219192
G4STRAP Insulated common connection strap 7219209
Generation 4 (G4) digital modules are single-channel I/O circuits with integral status Fuse Spare fuse for modules 581320
LEDs and integral fuses on the output modules. The modules are designed to work inc183b
with 5 and 24 VDC logic voltages and to plug into the Generation 4 family of I/O
mounting racks only. Price Each
Order Code 1+ 10+ 25+ 50+ 100+
AC Input Modules.
721-8904
Used for sensing ON/OFF AC voltages
721-8916
Designed with filtering on the input and a hysteresis amplifier for high noise
721-8928
rejection and transient-free clean switching
721-8930
Each module provides up to 4,000 V rms of optical isolation between field inputs
721-8941
and the logic side of the circuit
721-8953
Applications include sensing the presence or absence of voltage, or sensing
721-8965
contact closures from typical sources such as thermostats, proximity,limit, selector
721-8977
pushbutton and toggle switches
721-8989
DC Input Modules 721-8990
Used for sensing ON/OFF DC voltages 721-9003
Designed with filtering on the input and a hysteresis amplifier for high noise 721-9015
rejection and transient-free clean switching.(except G4IDC5B and G4IDC5K) 721-9027
G4IDC5B and G4IDC5K modules are fast-switching and very fast input modules for 721-9039
signals produced by photoelectric switches, encoders, DC proximity switches, or 721-9040 .
TTL devices 721-9052
Each module provides up to 4,000 V rms of optical isolation between field inputs 721-9064
and the logic side of the circuit 721-9076
Applications include sensing the presence or absence of voltage, or sensing 721-9088
contact closures from typical sources such as TTL compatible devices, proximity, 721-9090
limit, selector, pushbutton, toggle and photoelectric switches 721-9106
AC Output Modules. 721-9118 .
Used for the controlling or switching of AC loads 721-9120
Each module provides up to 4,000 V rms of optical isolation between the field 721-9131
devices and the control logic 721-9143
Modules feature zero voltage turn-on and zero current turn-off 721-9155
Aplications include switching AC relays, solenoids, contactors, motor starters,
heaters, lamps and indicators
721-9167
721-9179
26
DC Output Modules. 721-9180
Used for controlling or switching DC loads 721-9192

Industrial Computing & PLC's 881


Each module provides up to 4,000 V rms of optical isolation between the field 721-9209
devices and the control logic Price Each
Applications include the switching of DC relays, DC solenoids, DC motor starters, 10+ 50+ 100+ 500+
DC lamps and DC indicators 581-320 1.23 0.99 0.87 0.75
G4 DC outputs are current sourcing outputs. The module connection to the load is
the positive connection
G4 Digital Mounting Racks. Microprocessor Interface Switches
Suitable for mounting the OPTO 22 G4 digital I/O module family
(Series 6 Input/Output System)
Industrial screw terminal barrier strips for field wiring
Rack options allow a direct 50 pin ribbon cable connection from the parallel port of Modules:
H=32, L=44, D=15.2
a PC to the mounting rack, or provide an interface between dissimilar voltage 8 way: H=9 (ex module), L=215, D=89
systems via barrier strip termination 16 way: H=19 (ex module), L=367, D=89
Note: All I/O racks must be populated with the same voltage modules (i.e. 5V or
24V), except G4PB4R which is an output rack only Compatible with 5 volt TTL, CMOS and NMOS
Microprocessor Logic Systems.
Ancillaries. Zero Voltage AC Switching.
Input and Output test switches available using G4SWIN and G4SWOUT Internal Transient Suppression.
Insulated common connection strap available using G4STRAP Photo Isolated.
For spare 4A module fuses, use Order Code 581-320
ac Input Modules 6201A, 6202A (Yellow Case) dc Input Module 6101A (White Case)

5 Volt Modules Description Order Code


G4IAC 90 to 140 volt universal input 7218904
G4IAC5A 180 to 280 volt universal input 7218916
G4IDC5 10 to 32 volt universal input 7218928 ac Output Modules 6401A, 6402A (Black Case) dc Ouput Module 6301A (Red Case)
G4IDC5B Fast 4 to 16 volt DC input 7218930
G4IDC5D 2.5 to 28 volt DC input 7218941
G4IDC5K Very fast 2.5 to 16 volt DC input 7218953
G4OAC5 90 to 140 volt AC output 7218965
G4OAC5A 180 to 280 volt AC output 7218977
G4ODC5 5 to 60 volt DC output 7218989
G4ODC5A 5 to 200 volt DC output 7218990 Voltage Input Current Maximum Maximum Alternate
G4ODC5R Normally open reed switch output 7219003 Range vs Voltage Load Voltage Load Current Part No. Order Code
5 Volt Switch Modules Description Order Code 1032V dc IN 32mA @ 32V dc 30V dc 25mA @ 80C 1DC5 308-572
G4IAC5MA Manually over-ridable 90 to 140 volt universal input 7219015 90140V ac IN 6mA @ 120V ac 30V dc 25mA @ 80C 1AC5 308-584
G4IDC5MA Manually over-ridable 10 to 32 volt universal input 7219027 180240V ac IN 6mA @ 240V ac 30V dc 25mA @ 80C 1AC5-A 308-596
G4OAC5AMA Manually over-ridable 180 to 280 volt AC output 7219039 360V dc OUT 15mA @ 5V dc 60V dc 3A dc @ 45C 0DC5 308-602
G4OAC5MA Manually over-ridable 90 to 140 volt AC output 7219040 12140V ac OUT 15mA @ 5V dc 140V ac 3A RMS @ 45C 0AC5 308-614
G4ODC5MA Manually over-ridable 5 to 60 volt DC output 7219052 24280V ac OUT 15mA @ 5V dc 280V ac 3A RMS @ 45C 0AC5-A 308-626
PLC133
24 Volt Modules
G4IAC24 90 to 140 volt universal input 7219131 Mftrs. Price Each
G4IDC24 10 to 32 volt universal input 7219143 Module Type List No. Order Code 1+ 10+ 100+
G4OAC24 90 to 140 volt AC output 7219155 10-32V dc input 6101A 308-572
G4OAC24A 180 to 280 volt AC output 7219167
G4ODC24 5 to 60 volt DC output 7219179
90-140V ac input 6201A 308-584
180-240V ac input 6202A .308-596
Digital Mounting Racks 3-60V dc output 6301A .308-602
G4PB4 4 position I/O rack, barrier termination for field and control 7219064 12-140V ac output 6401A 308-614
G4PB4R 4 position output only rack,
barrier termination for field and control 7219076
24-280V ac output 6402A 308-626

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 881
Industrial Computing & PLC's
Single Channel I/O Modules continued Voltage Trip Board
Buffered Output Modules
MOS logic/microprocessor compatible Inverting/Non inverting options
Output for photocoupler/LED status display
Input Current Maximum Maximum Order
Type Voltage Range vs Voltage Load Voltage Load Current Code
Non-inverting 360V dc OUT 75A @ 0.8V dc 60V dc 3.5A dc @ 45C 308-638
Non-inverting 12140V ac OUT 75A @ 0.8V dc 140V ac 3.5A RMS @ 45C 308-640
Non-inverting 24280V ac OUT 75A @ 0.8V dc 280V ac 3.5A RMS @ 45C 308-651
Inverting 360V dc OUT 75A @ 2.4V dc 60V dc 3.5A dc @ 45C 308-663
Inverting 24280V ac OUT 75A @ 2.4V dc 280V ac 3.5A RMS @ 45C 308-687 H=18, W=64, L=100
Mounting 4 holes 3 dia, Fixing centres=84 49
AC Buffered Output Modules 6411, 6412 DC Buffered Output Modules 6311 (can be mounted on pillars above tachometer board 179-932)
(non-inverting), 6421, 6422 (inverting) (non-inverting), 6321 (inverting)
(Black Case) (Red Case) Voltage level detector with variable input & hysteresis
Active O/C PNP & NPN outputs (SIL relay & opto options)
Inverting or non-inverting Input-to-Output logic
Uses MAX8211-NO output jitter or oscillation
100% tested, PLC compatible, wide supply range
Supply +9 to +30Vdc (<6mA)
Trigger voltage +2.3 to +7.5V, Pot. adjustable (range can be modified by resistor addition)
*A non-inverting buffered output module turns on when pin 4 is held in the low state (logic 0), the Field connections Via 8 way screw terminal block
same as standard modules. An inverting module conversely turns on when pin 4 is held high, Indicators Red power and output LEDs
(logic 1). Mftrs. List No MSLD3/1
PLC134
FOR SIL RELAYS, SEE 176-577 TO 176-579, SECTION 4.18
Mftrs. Price Each PLC18
List No. Order Code 1+ 10+ 100+
Price Each
dc module 6311 308-638
Order Code 1+ 5+ 10+ 25+
ac module 6411 308-640
ac module 6412 308-651 179-933
dc module 6321 308-663
ac module 6422 308-687
Industrial Computers
Mounting Boards Industrial PC 12.5 Inch
Mftrs. Price Each
List No. Order Code 1+ 10+ 50+
8 way MS-8H .308-699
16 way MS-16H 308-705

26 DMP Series Standard


Input/Output Modules
Industrial Computing & PLC's 882

Epoxy coating provides environmental protection


Identical pinout to series 6 types (interchangeable)
1024 768 12.5" colour LCD display with CCFL backlight
Industrial PC
6.5G hard disk, 64M RAM
4 serial ports RS232 and RS485
H=38, W=48, D=12
Parallel port
Input Currentvs Max. Load CD and floppy front accessible
Voltage Range Voltage Voltage Max. LoadCurrent Order Code
24 function keys and alpha numeric keys
10 32V dc IN 32mA @ 32V dc 30V dc 25mA @ 80C 308-729 USB port Ethernet port
90 140V ac IN 6mA @ 120V ac 30V dc 25mA @ 80C 308-730
Resisitive touch 400M Pentium Class processor
3 60V dc OUT 15mA @ 5V dc 60V dc 3.0A dc @ 45C 308-742
24 280V ac OUT 15mA @ 5V dc 280V ac 3.0A rms @ 45C 308-754 Win NT/98 operating system IP65 NEMA4
PLC135 Expansion capabilities CE marked
Mftrs. Price Each Supply voltage: 110/240 AC Operating temperature: 0-50C
PLC232
List No. Order Code 1+ 10+ 100+
dc input module DMP6101A 308-729 Price Each
ac input module DMP6201A 308-730 Description Order Code 1+ 2+ 5+
dc output modue DMP6301A 308-742 MI12.5COLOURT Steel 353-2823
ac output module DMP6402A 308-754 MI12.5COLOURTS Stainless Steel 353-2811

Tachometer/Trip Boards Soft PLC


Frequency to Voltage (Tachometer) Board IMO SoftPLC is a software solution
which transforms the processing
Linear frequency to voltage converter power of an Intel based industrial
Accepts NPN, PNP, TTL & VR sensors PC into a fully functional PLC. IMO
Scaleable output voltage & LED status Soft PLC combines PID, discrete
Butterworth filter for low ripple output and analogue I/O with the data handling, computational
100% tested, PLC compatible & wide supply and networking capabilities of a computer. The soft-
range ware runs its own real-time Kernel and takes over from
H=18, W=64, L=100 the operating system of the PC in a deterministic man-
Mounting 4 holes 3 dia. Fixing centres=84 49 ner. With IMO SoftPLC's optional webserver and Java
Applications include tachometers, flow transducers, speed governors, analogue inter- virtual machine, a large proportion of the functionality
facing to PLCs etc. of HMI's and SCADA can be replaced
Supplied with instruction leaflet and range selection devices. Up to 8192 I/O
Supply +9 to +30Vdc (<10mA excluding sensor) Drivers for Profibus, DeviceNet and Interbus
Field connections Via 8 way screw terminal block Drivers for IMO range of Industrial PCs
Indicators Power LED, NPN and PNP device indication LEDs SoftPLC is programmed with TOPDOC
Mftrs. List No. MST2/1 TOPDOC is a feature rich program development, monitoring and documentation
PLC17
package
Price Each TOPDOC provides powerful on-line features, ladder monitoring, I/O forcing, contact
Order Code 1+ 5+ 10+ histogram, SoftWIRES program emulation and real on-line program change
Programming toolkit includes programmers guide and allows the user to define C,
179-932 C++ and Java functions to use with SoftPLC to create custom ladder instructions
I/O drivers and more

882 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
System Requirements: CRT Bezels
386 or better CPU DOS 3.3 or better (for installation only)
4MB RAM memory (SoftPLC), 16MB I/O interface cards and/or fieldbus cards A range of CRT Bezels manufactured in
(SoftPLC + Java JVM) black ABS plastic, UL94HB rated
4MB fixed disk (SoftPLC), 16MB fixed disk Comms, interface (e.g. COM port, Front mount bezel has a clip fitting for
(SoftPLC+Java JVM) Ethernet card) panels up to 3mm thick
Parallel port Windows 95 or NT, 5MB available Rear mount type can be mounted with
SPZ-1K-SOFTPLCKERNEL 328-0317 TDSPZ-FNW 328-0330 adhesive, double sided tape or screws
SPZ-2K-SOFTPLCKERNEL 328-0329 SPLIC-PTK 328-0342 (see Sections 7 and 11).
INC275

Price Each 176-597 Front Mount 5"


Order Code 1+ 5+ 10+
SoftPLC Kernel - up to 1024 I/O 328-0317
SoftPLC Kernel - up to 2048 I/O 328-0329
TOPDOC development software 328-0330
Programming Toolkit 328-0342

Industrial Monitors
10" Multi Frequency Colour
Design for use with
many industrial based control systems as a
Rear Mounting
replacement or upgrade monitor
With video resolutions from CGA (640 x 200)
to SVGA (800 x 600)
Cut-out in
The monitor provides connection for analogue: Front Panel
R
RGB (5 x BNC) & VGA: (high density 15 way Size Mounting sph. R1 R2 R3 a b c d e f g h i L W
D)
Front
The 10" monitor is housed in a durable metal 5" 350 3 2 5 102 78 110 85 6 13 15 11 2.5 116 91
case designed for heavy industrial applications
Front 3 193 143
H=253, W=259, D=313
and may be stacked 9" 635 3 2 6 180 130 187 137 6 11 15 8
Rear NA 200 150
CRT 12" Front 635 5 6 8 240 170 250 180 8 14 20 8 3 259 189
Size: 10" Dot Pitch: 0.26mm
Screen: Black matrix (anti-reflective, anti-static) to MPRII standard OC203

Sync Timings Price Each


H/scan frequency: 15kHz to 40kHz V/scan frequency: 45Hz to 100Hz
Video: Analogue video and seperate TTL level syncs or sync on Green via BNC
Order Code 1+ 25+ 50+
connectors 5" front mount 176-597
Resolution: 800 600 maximum Weight: 10kg 9" front mount 176-599
Cabinet: Beige coloured metal, stackable case 9" rear mount 176-600
Power 10" rear mount 881-030
Supply: 110V/240V ac Consumption: 100W max
OC288
12" front mount 176-601
26
Price Each
Order Code 1+ 3+ 10+ Data Acquisition Cards

Industrial Computing & PLC's 883


648-292
PC Bus Development Tool
PROTO-1
10" and 14" VGA/SVGA Colour
Chassis
Designed for use in a variety of applica-
tions for monitoring and test systems,
where it can be fitted internally into
racks and consoles etc
Ideal for many OEM applications with a
Provides a means of rapidly developing input/output mapped PC bus cards.
variety of mechanical fixings
With video resolutions of VGA (640 x 8 bit ISA bus prototyping card Up to 32 ports
480) & SVGA (800 x 600) Selectable base port address Buffered data bus (D0-D7)
The two sizes of monitor 10" & 14" both Buffered address bus (A0-A4)
have full EMC shielding to meet all CE Control lines (IORD, IOWR, MRD, MWR) Full size card with large patch area
and International Safety Regulations
Price Each
Mftrs. List No. Order Code 1+
PROTO-1 178-064
CRT
Size: 10"/14" Screen: Black matrix
Dot pitch: 0.28mm Anti-reflective, anti-static
PC Bus Development Tool
Scan Timings
H/Scan frequency: 31.5kHz/37.8kHz Video: Analogue video + separate TTL level syncs EXT-1
(Dual Scan) to IBM VGA/SVGA standard:
V/Scan frequency: 49Hz to 72Hz Bandwidth >45MHz
Allows PC and AT bus cards to
be connected but remain
Chassis
Type: Metal Total weight: 10" Monitor 6.5kg
accessible outside the PC itself
14" Monitor 9.5kg Useful where the PC card is being developed,
Power Supply calibrated or in any situation where access to the
Supply: 110V/240V ac Consumption: 85W max. card is needed whilst in service
Connectors: 1 15 way (female) D Type VGA PC/AT bus extender
Resolution: Pixels V Frequency All lines extended
800 600 56Hz (60Hz on 14") Track cut and link options
640 480 60Hz All lines labelled
640 400 70Hz
640 350 70Hz
Operating temperature: 0 to 55C
OC110
PLC262

Price Each Price Each


Order Code 1+ 3+ 10+ Mftrs. List No. Order Code 1+
10" Monitor 971-285 EXT-1 178-065
14" Monitor 971-303
continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 883
Industrial Computing & PLC's
General purpose input/output card
Data Acquisition Cards continued 8255 compatible, inputs and outputs
44 Channel Multi-Function 3 on-board 16 bit counter timers (8254 compatible)
Facility to fit pull up/down resistors on inputs
PCI-ADC
1 50 way male D type connector
PLC227

Price Each
Mftrs. List No. Order Code 1+
PCI-PIO 723-4831

Watchdog Timer
PCI-WDT

Designed to read several sensor ranges which make this card ideal for multi-point data
logging.
8 differential inputs or 16 single-ended inputs. 12 bit resolution
4 12 bit analogue outputs
24 programmable digital I/O channels at TTL levels
3 on board 16 bit Counter Timers (8254 compatible)
Suitable for monitoring input voltages with a full scale reading as low as 5mV
Sample and hold amplifier provides accurate readings at varying input signals
Analogue voltage and current outputs are bi-polar
Digital inputs can be either voltage or volt free contacts
Software configurable
Auto calibration Automatically monitors critical PC functions to predict serious problems before they
1 50 way male D type connector happen giving time for corrective actions to be taken.
PLC208
On-board Watchdog timer
Price Each Power rail monitoring
Mftrs. List No. Order Code 1+ Isolated digital input
PCI-ADC 723-4818 Digital and relay output
Monitors hot spots in computer system using remote temperature sensor
On-board audible alarm
All functions selectable under software control
32 Channel Isolated Digital Input/Output I/O connections via two part screw terminal
PCI-DIO PLC225

Price Each
Mftrs. List No. Order Code 1+
26 PCI-WDT 723-4843

PCI Drivers Windows 98 and 2000


Industrial Computing & PLC's 884

With the advent of Windows 98 and Windows 2000


comes a new device driver model WDM (Windows Driver Model)
that has the same device driver interface. To keep up with these
advances in operating system features, Blue Chip Technology have
introduced a range of WDM drivers for the PCI data acquisition
cards.
These new drivers keep the same API provided by the drivers designed for Windows
Capable of reading contact closures and switching relays up to 24V. NT and allow the use of the PCI data acquisition cards with the latest members of the
Microsoft Windows operating system family, thereby allowing easy migration of appli-
Wide input voltage range suitable for industrial applications (0-36V DC/AC) cations already developed. For new applications, the same level of documentation and
Individually opto-isolated inputs sample applications are provided in the installation.
Opto-isolated outputs PLC210
Individually opto-isolated counter timer inputs and outputs
3 on-board 16 bit counter timers (8254 compatible) Price Each
Software configurable 1 50 way male D type connector Mftrs. List No. Order Code 1+
PLC226 PCI-WIN2000 343-4990
Price Each
Mftrs. List No. Order Code 1+
PCI-DIO 723-4820
PCI Drivers Windows NT
Designed to support the Blue Chip Technology range
of PCI data acquisition cards this kernel mode device driver and API
48 Channel Programmable Input/Output (Application Programming Interface) library provides an easy way
for the programmer to develop applications for Windows NT using
PCI-PIO Visual Basic, C/C++ and Delphi.
A simple installation procedure ensures that all the system files are copied to the cor-
rect locations along with an on-line manual for the drivers and sample programs. All
necessary registry keys and settings are added as part of the installation procedure
and application development can start within a matter of minutes.
The API provides simple functions that allow access to the hardware functions provid-
ed by the PCI data aquisition cards without the developer requiring an indepth knowl-
edge of the card or the associated Windows NT architecture. Having been designed
specifically for Windows NT these drivers fully support multi-threaded applications.
PLC209

Price Each
Mftrs. List No. Order Code 1+
PCI-WINNT 723-4855

Designed as a general purpose interface to most other digital devices ie. switches,
LEDs and parallel ports.

884 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
24 Channel Opto-isolated Digital Input Multi-channel Digital Combination
DIP-24 DCM-16

Designed to offer a wide range of digital input/ output and pulse handling facilities.
Interrupt facilities enable the card to be used where digital inputs trigger other events,
Designed for sensing inputs from switches or volt-free contacts in industrial or labora- or where timed interrupts initiate other inputs, scanning or control.
tory conditions.
8 opto-isolated inputs 8 opto-isolated Darlington outputs
24 digital input channels 3 16 bit counter/timer On-board clock source
Fully opto-isolated to 500 volts Link selectable interrupts 50 way IDC connector
Inputs configurable from 5 to 24 volts AC/DC PLC248

Optional on-board voltage source Price Each


50 way IDC connector
PLC245
Mftrs. List No. Order Code 1+
DCM-16 176-929
Price Each
Mftrs. List No. Order Code 1+
DIP-24 176-925 64 Channel Digital Input/Output
DIG-64

24 Channel Opto-isolated Darlington Output


DOP-24

A multi-purpose digital input/output card ideal for process control applications.


16 digital opto-isolated inputs
16 relay outputs with or without mercury wetted contacts
32 digital programmable input/outputs
User selectable base address and interrupt level
Field replaceable series resistance packs allow selection of the input voltage range
Polyswitch resettable fuses protecting relay outputs and +5 volt/+12 volt outputs
26
Allows relays and solenoids to be driven directly for control applications. 37 way D-type and 40 way IDC connectors
24 digital output channels Opto-isolated to 500 volts PLC249

Industrial Computing & PLC's 885


Switches up to 24V DC Darlington drivers sink up to 400mA
Optional on-board voltage source 50 way IDC connector Price Each
PLC246
Mftrs. List No. Order Code 1+
DIG-64 343-4862
Price Each
Mftrs. List No. Order Code 1+
DOP-24 176-926
10 Channel Pulse Counter/Timer/Generator
48/96 Channel Programmable Input/Output DPC-10
P10-48/96

Designed as general purpose interfaces to other digital devices ie. switches, LEDs and Provides the capability for counting pulses, complex pulse generation, stopwatch tim-
parallel ports. ing, coincidence alarms and much more all under software control.

48/96 digital channel options Programmable as input or output 10 programmable channels Counter/timer/generator functions
Configurable under software control 5 volt TTL logic signals 16 bit counters, cascadable 50 way IDC connector
50 way IDC connector Full interrupt support 4MHz on-board clock
PLC247 Programmable pulse outputs 50 way IDC connector
PLC250
Price Each
Mftrs. List No. Order Code 1+ Price Each
P10-48 176-927 Mftrs. List No. Order Code 1+
P10-96 343-4850 DPC-10 176-928

continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 885
Industrial Computing & PLC's
Data Acquisition Cards continued 8 Channel 12 Bit Analogue Output
AOP-8
48 Channel Opto-isolated Digital
Input/Output
DIO-48

Designed to drive external devices ie. controllers and motors, can also be used where
Ideal for activating relays and solenoids in process control applications.
an analogue control voltage up to 10mA is needed.
24 opto-isolated digital input channels 24 opto-isolated digital output channels
8 independent analogue outputs 12 bit resolution
Fully isolated to 500V Input range from 5 to 24 volts AC/DC
0-10 volts, programmable output 1.5S settling time
Switches up to 24V DC Darlington drivers sink up to 400mA
Non-linearity 1 bit 50 way IDC connector
Optional on-board voltage sources Two 50 way IDC connectors
PLC254
PLC251

Price Each Price Each


Mftrs. List No. Order Code 1+ Mftrs. List No. Order Code 1+
DIO-48 343-4874 AOP-8 176-931

32 Channel Opto-isolated Digital Multi-function 12 Bit Combination


ADC-44D
Input/Output
DIO-32D General purpose analogue/digital card with on-board interrupt capa-
bility ideal for machine control applications.
16 single-ended or 8 differential analogue inputs
10V, 5V, 1V, 100mV and 50mV input range
x 1, x 2, x 10 and x 100 programmable gains
3S, 12 bit resolution A to D conversion
Direct Memory Access (DMA) A/D and D/A
Four, 12 bit analogue outputs 10V @ 20mA
24 digital I/O channels (82C55)
26

50 way male D-type (analogue)
50 way IDC-header (digital)
PLC255
Industrial Computing & PLC's 886

Price Each
Ideal for activating relays and solenoids in process control applications. Mftrs. List No. Order Code 1+
16 digital input and 16 digital output channels ADC-44D 343-4898
Fully isolated to 5400V Link selectable interrupts
3 16 bit timers (82C54) 50 way D-type connector
PLC252 Multi-function 12 Bit Combination
Price Each ADC-42
Mftrs. List No. Order Code 1+
DIO-32D 343-4886

24 Channel 12 Bit Analogue Input


AIP-24

Combines the most popular input/output functions on one card.


16 single-ended or 8 differential analogue inputs
12 bit, 10S ADC 2 bit analogue outputs
12 bit DAC 24 programmable I/O ports (TTL)
50 way IDC connector
PLC256

Price Each
Ideal for reading up to 24 analogue voltages from the shop floor.
Mftrs. List No. Order Code 1+
24 single ended or 12 differential channels 12 bit ADC uni/bi-polar operation
Up to 8S conversion 20KHz throughput ADC-42 178-061
Programmable gain amplifier Sample and hold amplifier
50 way IDC connector
PLC253

Price Each
Mftrs. List No. Order Code 1+
AIP-24 176-930

886 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
8 Channel Analogue to Digital Multi-function Watchdog
AIP-8 WD-1

Automatically monitors critical PC functions to predict serious problems before they


Designed for monitoring analogue outputs, typically machine outputs. happen, giving time for corrective action to be taken.
User selection base address, interrupt level and on-board timer which can be used PC Watchdog timer, monitor/alarm Power supply and fan monitor
to control A to D conversion cycles External input monitoring Voltage free fault indication contacts
12S conversion time 25 way male D type connector Software selectable functions Plug in 2-part screw terminal connec-
3 16 bit timers (82C54) Power requirements 5V dc at 150mA tions
PLC260
PLC257

Price Each
Price Each
Mftrs. List No. Order Code 1+
Mftrs. List No. Order Code 1+
WD-1 343-4930
AIP-8 343-4904

12 Channel Digital to Analogue 2 Channel Serial Communications


AOP-12D SIO-2
Allows communication
between computers,
printers, plotters,
instruments and any
device with a serial interface.

2 serial channels
Link selectable RS232/422/485 or
20mA loop
Selectable interrupt channel
Selectable base address 26
Parallel port option
16C550 UART Windows option3
Ideal for driving stepper motor controllers or any device requiring an analogue input.

Industrial Computing & PLC's 887


PLC212

12 analogue outputs 10V 24 TTL digital inputs/outputs Price Each


50 way male D type connector 3 16 bit timers (82C54) Mftrs. List No. Order Code 1+
Power requirements 5V dc at 350mA
PLC258
SI0-2 176-941

Price Each
Mftrs. List No. Order Code 1+ 4 Channel Serial Communications
AOP-12D 343-4916 SIO-4D

8 Channel Relay
RB-8

Allows communication between computers, printers, plotters and instruments pro-


vides 4 serial ports and 2 parallel ports.
Selectable RS232/422/485 serial channels
Link selectable serial channels as COM1 to COM8
With 8 on-board relays capable of switching up to 3A it is ideal for general control Parallel channels selectable as LPT1/LPT2
applications. 1 25 way and 1 9 way male D type connectors
8 individually controllable relay outputs Link selectable power up state 3 16 bit timers
Up to 3A contact rating Occupies only one I/O address space Power requirements 5V d.c. at 500mA
PLC213
Plug in 2-part screw terminal connections
PLC259
Price Each
Price Each Mftrs. List No. Order Code 1+
Mftrs. List No. Order Code 1+ SIO-4D 343-4953
RB-8 343-4928 continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 887
Industrial Computing & PLC's
Data Acquisition Cards continued PC/104 Embedded PC
ISA Drivers Windows 3.1 Development Kits
Dynamic Link Libraries PC- compatible 100MHz 4865X

Two Windows 3.1x DLLs (Dynamic Link Libraries) are available.
These allow the functions of the ISA data acquisition and serial com-
munications cards to be used by applications developed using all
the popular Windows 3.1x development tools.
PLC211

Price Each
Mftrs. List No. Order Code 1+
DATACQDLL 343-5003
SERIALDLL 343-5015

Configurable Data Acquisition System 6B Modules


For any Computer with an RS232 Interface
Complete sensor to RS232 or RS485 interface Dramatically reduce the time required to develop new embedded applications. Kits
Input modules for Thermocouples, mV and V. contain all of the commonly required power supplies, cables etc, needed to get you
Software configurable for sensor and input running quickly. More importantly, target builds of the offered operating systems are
range pre-loaded, meaning that you can immediately start work on application development.
Linearised outputs in engineering units ELAN-104NC processor board with ROM DOS or Windows CE Pre-Loaded
High resolution 16 bit integrating convertor Rugged PSU
500V rms isolation PS/2 mouse
Interface cables for VGA/CRT, Keyboard, FDD and Serial Programming link
CD-ROM containing various OS Flash disk images and sample code
Comprehensive user documentation, tutorial and example applications
All appropriate licenses
H=77, W=18, D=58.
Optional 6.5" NEC TFT. Flat-Panel Display
Two input modules are available:
SEE 341-6185, PAGE 888 FOR PROCESSOR DESCRIPTION
The 6B11 accepts inputs from J, K, T, E, R, S and B thermocouples, millivolt, and volt
INC280
signals and provides an isolated RS485 output. For thermocouple inputs all signals are
linearized and cold junction compensation is accounted for. The output can be in volts,
Price Each
millivolts or C.
Order Code 1+
The 6B12 accepts inputs at 150mV, 500mV, 1V, 5V, 10V, 50V and 20mA. ELAN DOS - No flat panel display 341-6148
Output is in the form of isolated RS485. ELAN DOS - With flat panel display 341-6150
PLC137 ELAN - Windows CE - No flat panel display 341-6161
ELAN - Windows CE - With flat panel display 341-6173
Modules Order Code Price Each
6B11 input 178-574
26 6B12 input 178-575 Embedded Processor Board
PC- compatible - 100 MHz Elan - 104 NC
Accessories
6B User manual and configuration disk 178-959
Industrial Computing & PLC's 888

Communications Adaptor
2
I C Communications Adaptor CALIBRE ELECTRONICS
Full I2C compatibility
I2 configuration through software
Can be used as a Master of a Slave
Software routines supplied in BASIC
and C
Transparent bus monitor functions A PC-compatible processor board, based on the AMD lan SC400 486SX microcon-
troller. Supplied in Eurocard format (100mm x 160mm) and featuring a 16-bit PC/104
A half length PC expansion card which expansion interface. The board implements a full architecture, using the 100MHz
2
supports the full I C communications pro- processor with power management.
tocol, PC1/O addresses, bus
termination/protection and hardware inter- 16Mbytes of EDO DRAM and 8Mb Flash
rupt line are all link selectable. Drive Support: FDD, HDD, Non-volatile Silicon Disk in Flash
I2 configuration and all other functions are software controllable including the data PC peripherals: Keyobard, mouse, LPT, GPIO
transmission mode and clock speed. Both polled and interrupt driven modes can be 3 x 16550 fast serial ports, 2 x RS232, 1 x RS422/485
supported, marking programming in popular languages easy. Long distance mode can Video: Flat Panel and CRT XVGA, 1Mbytes EDO Video Memory
be supported with the addition of external line drivers (for which a +5V output is pro- Matrix backed Real-time clock and Watchdog
vided) Network support 10 BASE-T Ethernet via RJ-45
Datalight Flash Filing system pre-loaded in bootable flash EPROM. (Bios extension
Software is provided in the form of function libraries in Turbo BASIC and C. These rou-
Allowing EPROM to be used as a bootable read/write drive)
tines implement the basic I2 functions for use with the user's programs. The functions
Available with ROM DOS 6.22 or windows CE operating system pre loaded
available are Adaptor Card Setup, (including SCL clock speed) start and slave address
transmission byte transmission, byte reception, stop transmission and access to a To download technical manual visit www.arcomcontrols.com
Status Register. Example programs are included which illustrate typical uses of the INC281
library functions.
Supplied with manual and software on 55" and 3" disks.
Price Each
PLC131
Order Code 1+ 5+
ELAN - DOS 341-6185
Price Each ELAN - WIN CE 341-6197
Order Code 1+ 3+ 10+
256-109
Compact Industrial PC Enclosure (ACEpc)
For Arcom Elan Processor Board

888 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
DIN Rail or Wall mountable 16-Channel Opto-Isolated Digital Output Module
Up to four PC/104 expansion boards
128 I/O breakouts via two part screw terminals
Integral 24V DC isolated power supply
-20C to +70C operating temperature (with Arcom PC/104 boards).
Full PC Breakout in end panel. (Keyboard, mouse VGA, com 1, 2 + 3, LPTI, net and
Reset)
Meets EN50081-2 Emissions, EN50082-2 Immunity (with Arcom I/O boards and no
keyboard).
Also available 50-way breakout cable for I/O expansion (ACE-CAB50) and Termination
connectors (ACE-TERMPACK)
FOR ELAN-104NC PROCESSOR BOARD
SEE ORDER CODE 341-6185 PAGE 888
INC290
Designed for Industrial automation, Optical isolation of PC from field devices, control
Order Price Each of actuators (outputs).
Code 1+
16 opto-isolated Darlington driver outputs
ACEpc Enclosure 341-6288
18V max load operating voltage
ACE-CAB50 341-6290
40KHz max output frequency
ACE-TERMPACK 341-6306
Catch diode on all outputs for protection when driving inductive loads
Module access LED
To download technical manual visit www.arcomcontrols.com
32-Channel Digital I/O Module INC284

Price Each
Order Code 1+ 3+ 5+
AIM104-OUT16 341-6227

8-Channel Relay Changeover Module

Designed for Digital I/O, Industrial control and monitoring, Interfacing to parallel I/O
devices.
32 digital channels
Bit programmable for input or output
Sink capability 24mA @ 0.45V or source current of 500A @ 2.7V
Module access LED
Define the power-up/reset state
To download technical manual visit www.arcomcontrols.com
INC285 Designed for Industrial on/off control, External contactor driving, Digital input monitor-
26
Price Each ing, contact status monitoring.
Order Code 1+ 3+ 5+ 8-changeover relays

Industrial Computing & PLC's 889


AIM104-IO32 341-6239 Relay drivers optionally disabled on power-up and reset
Read-back status register
Maximum power switching rating: 60W
Defined power-up state
16-Channel Opto-Isolated Digital Input Module Normally closed (NC) and Normally open (NO) contacts available
8 opto-isolated digital inputs: 10V to 30V range
10mS input debounce filters (link selectable)
Module access LED
To download technical manual visit www.arcomcontrols.com
INC288

Price Each
Order Code 1+ 3+ 5+
AIM104-RELAY8/IN8 341-6264

PC/104 I/O Modules


16-channel 12-bit ADC, 8-channel Opto-Isolated Digital Input Module

Designed for Industrial automation, Optical isolation of PC from field devices,


Monitoring of sensors (inputs).
16 opto-isolated digital inputs
Input switching voltage: 10 to 30V
Maximum input frequency 50Hz with filters; 10KHz without filters
Reverse protection diodes on all inputs Option for 10mS input debounce filters on
each channel
Module inputs driven by external power source
Module access LED
To download technical manual visit: ARCOM WEB SITE Designed for Waveform analysis, Digital input monitoring.
INC283
8-channel opto-isolated digital inputs: 10V to 30V range
Price Each Link selectable 10ms input debounce filter
Order Code 1+ 3+ 5+ 16-channel single-ended or 8-channel differential 12-bit ADC input
AIM104-IN16 341-6215 Maximum acquisition rate 500Hz
Bipolar -5V to + 5V input range
Module access LED
To download technical manual visit: ARCOM WEB SITE
INC282

Price Each
Order Code 1+ 3+ 5+
AIM104-ADC16/IN8 341-6203

continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 889
Industrial Computing & PLC's
To download technical manual visit www.arcomcontrols.com
PC/104 Embedded PC continued INC286

Motion Controller Price Each


Order Code 1+ 3+ 5+
16-Channel 12-Bit ADC, 2-Channel 12 Bit DAC,
AIM104-MOTION-1 341-6240
8-Channel Opto-Isolated Digital input module

Embedded Control System


Scorpion K4S MICROROBOTICS

Designed for Waveform generation, Waveform analysis, Digital input monitoring


8-channel opto-isolated digital inputs: 10V to 30V range
1500V input to output isolation
Option for 10mS input debounced filter H=24, W=82, D=59
16-channel single-ended or 8-channel differential 12-bit ADC input
Maximum acquisition rate 500Hz K4S Control Module
Bipolar -5V to +5V input range The K4S is the latest in the K4 range of credit-card-sized embedded control computers.
2-channel 12-bit DAC output Entirely backward-compatible with the original K4, it is based on the Hitachi 63C03
Bi-polar -5V to +5V or 0-25mA output range processor running at 2.45 MHz and comes with either 32K or 128K of battery-backed
Module access LED RAM. There are 16 general-purpose digital I/O lines, along with a watchdog and a
To download technical manual visit www.arcomcontrol.com clock/calendar option. Interfaces include three serial ports (one of them transmit only,)
INC287
an I2C bus with up to 128 digital and 40 analogue I/O channels, pulse measurement,
Price Each pulse generation, graphic and alphanumeric LCD's, keypads, Microwire support, and
Order Code 1+ 3+ 5+ a system expansion bus. In use the K4S is plugged into one of the application boards
provided, or a custom board.
AIM104-MULTI-IO 341-6252
K4 Control Language (Flash)
Quickly understood by anyone familiar with BASIC, Pascal or C, the K4 language offers
Signal Processing Module a powerful easy-to-use multi-tasking development environment. As well as proce-
dures, functions and both integer and floating point arithmetic, a wide range of object
orientated drivers are provided. These simplify commonly required user interface
operations and communicate with a wide variety of I/O devices
The K4 language provides excellent support for graphics LCDs with multiple windows
proportional fonts, word wrapping/justification, automatic bar graphs and more. K4S
26 controllers are easy to network using protocols built into the language
The K4S can be programmed using any computer with a 9,600 baud serial link. The
full-screen text editor and command line allow instant entry modification and trial of
software
Industrial Computing & PLC's 890

Using Flash memory devices removes the need for EPROM programmers and erasers
during application development. Applications can be stored and run from Flash mem-
ory keeping the battery-backed RAM free for storage data, without wasting valuable
time erasing and programming EPROMs
For distribution your completed application can be copied into a cheaper EPROM pack-
8-bit PC/104 module (16-bit connector fitted to enable bus to be through connect- age and the application may also be 'secured' to stop it being listed or modified. A
ed). K4S 128K is needed to program Flash memory through either variant may run form it.
Can be configured for status, accumulator, frequency, trapezoidal etc. inputs Application program space is very large at 96K
Based around the Hitachi HD63140CP (UPP)
Isolated voltage 1KV DC, field controller
Maximum operating frequency 100KHz K4 Introductory Manuals
Link selectable noise filters (Bandwidth 100Hz) Includes Designing with the Scorpion K4 and The K4 Hardware Reference. Contains over
Board access LED 300 pages of worked examples, explanations and circuits.
I/O mapped on the PC/104 bus
Registered access address space 4-bytes K4 Programmers Reference Manuals
Interrupt generation based on input status changes A 500 page comprehensive programmers manual
All inputs include reverse input protection diodes
Input voltages @ opto-inputs +10V min to +36V max Application Board 1
To download technical manual visit www.arcomcontrols.com Provides the following interfaces for the K4S.
INC289
Serial Port 1: up to 19,200 baud RS232, or RS485 (full or half duplex).
Serial Port 2: up to 1,200 baud RS232.
Price Each Serial Port 3: up to 1,200 baud RS232 Tx only.
Order Code 1+ 3+ 5+ 23 general-purpose digital I/O lines that may be configured for Alpha-numeric LCD,
AIM104-PULSE 341-6276 Keypads, or Parallel Printer.
General-purpose I2C port.
Power requirement: 5V dc, regulated.
Motion Controller Application Board 2
As the application board 1 but with 8 channel, 12-bit ADC, 0 - 5V.
Application Board 3
Provides the following interfaces for the K4S.
Graphics LCD with the provision for EL backlight inverter.
Alpha-numeric LCD.
Serial Port 1: up to 19,200 baud RS232, or RS485 half duplex.
Serial Port 2: up to 1,200 baud RS232, or RS485 half duplex.
Serial Port 3: up to 1,200 baud RS232 transmit only.
16 general purpose digital I/O lines, may be used for keypads up to 8 by 8.
Single-axis DC servo/stepper controller (HCTL-1100) on-board 1A motor drive 16 channel Universal Pulse Processor (UPP).
2/3 ch input for incremental encoder (single/differential) Fitted with a 10 channel 10-bit ADC.
4 opto-isolated inputs: Limit 1, Limit 2, Stop, Home Normal and Long Distance I2C Ports
Selectable motor current limit, programmable digital filter Microwire port.
Control modes: Position, Velocity, Trapezoidal Profile Modem power supply.
Link-selectable IRQ3-15: Module access LED, Motor power LED Power requirement: 8-30V dc.
Interrupt on status change (Limit, Stop, Profile complete).` PLC124A

890 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
K4 Development Board 2 Relay Card
Provides the following interfaces for the K4S. I/O channels: 8 n/o relay contacts
I2C bus channels used: 8 of 128* digital
Serial Port 1: up to 19,200 baud RS232.
Output rating: 6A @ 240V ac
11 general-purpose digital channels.
Size 92 97mm
General-purpose I2C
Power supply: 10-28V dc, 120mA nom.
Universal Pulse Processor (UPP) with 10 cannel bit ADC. See Application Board 3
entry for details of the UPP. Digital Output Card
I/O channels: 16 opto-isolated MOSFETs, n-channel, open drain
Power Supply I2C bus channels used: 8 of 128* digital
Capable of supplying 1.2A @ 12V (unregulated), suitable for powering development On resistance: 0.05
board 2 and the Scorpion controller. Output rating: 4A @ 30V dc
Size: 87 97mm
PCF8574P (204-020)
Digital Input Card
An I2C compatible IC with 8 digital I/O lines.
I/O channels: 16 opto-isolated inputs, 2 banks of 8, +ve or -ve polarity
PCF8583P (403-908) I2C bus channels used: 16 of 128* digital
Optional clock/calendar that plugs directly into the K4S. Input voltage: 24V dc nom.
Size 91 93mm
PCF8591P (396-412)
*The first 64 digital channels are available immediately and the second 64 are available
An I2C compatible IC with 4 analogue inputs (8 bit) and one analogue ouptut (8 bit).
by substituting alternative driver chips in place of those supplied in the card. This is a
PLC124B simple and inexpensive operation.
PLC162
Mftrs. Price Each
List No. Order Code 1+ 5+ 25+ Mftrs Order Price Each
K4S Control module 32K 5520 517-823 List No. Code 1+ 3+ 5+
K4S Control Module 128K 5521 517-835 Relay Card 5620 898-053
K4 Language FLASH 5524 517-847 Digital Output Card 5621 898-065
K4 Introductory Manuals 5514 207-494 Digital Input Card 5622 898-077
K4 Programmers' Manuals 5515 207-500
Application board 1 5522 517-859
Application board 2 5523 517-860
Application board 3 5525 517-872
K4 Development board 2 5503 179-345
Smart Card Readers/Writers
Power Supply 1003 177-543 Contactless smart card read/write modules COMTECH
Price Each
Order Code 1+ 10+ 100+ 250+
I/O Expander IC 204-020.
Clock/calendar IC 403-908.
A/D and D/A IC 396-412.

I/O Ports MICROROBOTICS


These ports are intended for interfacing low level signals inside an equipment housing.
They may be connected to Scorpion K4S and Scorpion control computers, or any con-
troller with an I2C bus. Scorpion series controllers provide full software support.
26
Hitag contactless smart card read/write modules
Digital I/O Port Utilizes a low frequency field to communicate with the Hitag 1 contactless smart-

Industrial Computing & PLC's 891


card
Up to four* of these I2C cards can be connected, each fitted with 16 TTL digital I/O
Both power and data are provided by the field, making the system rugged and reli-
channels, together with prototyping area.
able
Analogue I/O Port A simple ASCII based command set allows users to interface the module to their
Up to four of these may be connected, each with 8 analogue inputs (8 bit, 0-5V) and host systems via a serial bus protocol
two analogue outputs (8 bit, 0-5V). Both RS232 and RS485 multidrop communications are supported
The BIS1702 module also features additional I/O including 2 power mosfet outputs,
Printer Port 2 opto isolated inputs, 4 LED outputs, a buzzer and 1k of scratchpad E2prom
An I2C board suitable for driving many different parallel printers. This board uses 16 of RS232 is configurable for baud rate, parity and stop bits
the 128 available digital channels. RS485 has jumpers to set the 1 of 32 modules address
Includes an integral antenna and a power regulator
*The number of cards may be doubled if the driver chips on the extra cards are Low power and continual seek modes are supported
replaced by PCF8574A parts. See section 2.8. ISO7812 smartcard can be read 150mm from either the back or front of the module
PLC127
BIS1701D features
Mftrs. Price Each Operating frequency 125Khz Quiescent current 50mA
List No. Order Code 1+ 5+ 25+ Integrated antenna E2prom configuration + user data
Digital I/O port 1022 177-544 ASCII command set 190 byte card memory data map
Analogue I/O port 1024 177-545 Single +5v or +8v to +13.5v power Encryption controller option
Printer port 1025 177-548 supply Suitable for applications in industrial,
RS232 port 600 - 9600 baud retail and office environments
Operating current during read/write Dimensions: 70 x 54 x 20mm
Industrial I/O Cards MICROROBOTICS 200mA
Additional Features on BIS1702 modules
RS485 port at 9600 baud 4 LED outputs (2 on module 2 exter-
32 unit can share multidrop bus nal)
2 high current mosfets (1.5A) 2 opto isolated inputs
Sounder
Technical data (BIS1701D and BIS1702 read/write module)
Parameter min typ max units
Read/write range 100 150 mm
Mosfet output current 1000 1500 mA
LED current 5 mA
Opto input current 5 mA
E2prom size 1k bytes
Operating temperature -10 50 C
OC554

Price Each
Description Order Code 1+ 5+ 10+
I2C and long distance I2C interface
Fully integrated with K4 language BIS1701D 301-8398
Pluggable screw terminals BIS1702 304-0902
Industry standard signal levels
Up to 20 cards of any type can be daisy chained together continued
LED level indicators
Isolated input and outputs

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 891
Industrial Computing & PLC's
BIS1601A features
Smart Card Readers/Writers continued
Reads and writes ISO7816 E2prom memory cards
Smart card read/write evaluation kit COMTECH ASCII command set
Single +5v power supply
RS232 port 600 - 9600 baud
Operating current during read/write 100mA max.
Quiescent current 25mA
E2prom configuration + user data
Read/writes ST140x memory cards
Powerful command set reduces host software overhead
Suitable for applications in industrial, retail and office environments
Configurable interrupt character on card detection
Dimensions: 100 x 65 x 22mm
Technical data (BIS1601A read/write module)
Parameter min typ max units
Read time (256 bytes) 1000 ms
Write time (256 bytes) 2500 ms
Supply voltage 4.75 5.25 V
Hitag contactless smart card read/write Evaluation Kit
Supply current operating 100 mA
Provides all of the features of the BIS1701D contactless read module in a simple to Baud rate 600 9600 baud
use environment Operating temperature -10 50 C
OC555
Includes a boxed read/write unit with 2 internal LEDs and connectors that bring
out all of the I/O and both the RS232 and RS485 communication ports Price Each
Standard PC RS232 cable and a power supply (UK) are supplied
Order Code 1+ 5+ 10+
To enable the user to access all of the read/write modules powerful features the
unit is supplied with a Win 95 GUI on CD rom and 2 Hitag 1 smartcards 301-8428
OC556

Price Each
Order Code 1+ 5+ 10+
Contact smart card COMTECH
301-8404 ST1402 contact smart card
Fully supported by the BIS1601A read/write unit
Featuring a 256 byte E2prom memory the card uses an I2C bus to communicate the
Contactless smart card COMTECH data to the integrated chip via the pad connector
Compliant with the ISO7816 middle position connector specification and the ISO
Hitag contactless smart card 10536.1 dimensional specification
The contactless smartcard is dimensionally compliant with ISO10536.1 and can Applications include: subscribers card, electronic access, membership cards, elec-
withstand bending and torsional cycles to ISO7816-1 tronic ticketing and data capture
Contains a Hitag 1 chip module and integrated rectangular antenna ST14C02 features
Needs no external power to operate, this is derived from the RF field and will oper-
3.3 to 5.5 volt operation
ate even in a wallet or pocket
2 wire I2C serial interface
Contains a 256 byte E2prom memory and crypto processor unit which can be used
Byte and multibyte write features
for enhanced communication security
Page write to 8 bytes
26 Hitag 1 features
Unique 32 bit factory programmed serial number
Byte random and sequential read
Self timed program cycle
256 byte read/write memory Automatic address increment
Read/write distance up to 700mm (depends on reader antenna) Enhanced ESD and latch up protection
Industrial Computing & PLC's 892

Supports both block and page read/write modes 1 Million erase/write cycles
Manchester encoded data with CRC checking 10 years data retention
Anti-collision encoding for multicard applications
OC562
Encryption unit for secure data communication (depends on reader)
Data retention 10 years Price Each
Operating temperature -20C to +50C
Order Code 1+ 5+ 10+
Protection IP67
301-8430
OC561

Price Each
Order Code 1+ 5+ 10+ Barcode Readers - Fixed
301-8416 Compact Laser Scanner
An ultra compact, high performance and low
cost laser scanner ideal for OEMs and other
Contact smart card read/write module COMTECH applications where reliability and integration
capability are key functions.

Scanning speed of 500scan/sec


0.15mm scan resolution
Dual serial interface
Reading range 50 to 220mm
4 status LEDs
Hitag contact smart card read/write unit (BIS1601A) IP65 rugged industrial housing
Ultra compact - 50x40x28mm
Self-contained module that can communicate with contact smartcards of the Light weight - 150g
ST140x family to provide a means of reading and writing data to the card DC converter - 4-30V dc to 5V dc - required if external 5V dc supply is unavailable
ISO standard contact head the cards are inserted into the reader where contact is Software, manuals and brackets are included with scanners
made via the card contact pad Use linear scanner for ladder orientation and raster scanner for picket fence orien-
Features an ASCII command set that provides a simple interface to the host via an tation
RS232 bus
Command set includes features such as card erase, checksum and configurable Typical applications include automatic machines, document handling machines, print-
baud rate ing vertification, packaging machine etc.
A 256 byte card can be read in under 1 second
Simple E2prom devices can be used to store user data for a wide variety of appli-
cations including tracking, retail, parking, customer loyalty, leisure and data log-
ging

892 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Power supply 5V dc +/-5% Output signals Two programmable Input signal 2 digital inputs
digital outputs Output signal 3 digital outputs
Power consumption 2W Programming method Via serial port LED indicators 7 communications status
Light source Visible laser diode Operating modes On line, Serial LEDs
On-line, Keypad 4 membrane keys
Test, Verifier SAT428
Max. depth of field 170mm Laser classification IEC 825 Class 2, Automatic
Aperture angle 52 degrees Case material Die-cast zinc Price Each
Readable codes 22 types incl. 2/5 Operating temp 0 to 40 deg C Mftrs. List No. Order Code 1+
family, Code 39,
Code 93, Code 128,
Controller MX4000-1000 314-1792
EAN/UPC, Codabar
EAN128, Code 49
Multi-label reading Up to 6 different codes in 1045 Fixed CCD Scanner
the same presence sensor
phase Compact and light
Comms. interface Dual serial interface (RS232/RS485) weight
Baud rate 150 to 19,200 bauds Easy mounting, can be used as a presenta-
Input signals One programmable digital input tion scanner
SAT430
Long range 8cm for 15 Mil element width
Resolution 0.125mm
Price Each
Cable selectable interfaces
Mftrs. List No. Order Code 1+ 3+ 5+
Dimensions L80mm x W60 x H29mm
Linear scanner DS2200-1100 314-1743 Durable, ideal for harsh environments
Raster scanner DS2200-1110 314-1755 demanding high depth of field, CCD technol-
DC Converter DC5-2200 314-1767 ogy scanners have no moving mirrors unlike
Power supply PG240-12 314-1779 conventional laser scanners
Advanced data editing and format programming modes supported
OC551

High Performance Laser Scanner Price Each


The units offer high Order Code 1+ 5+ 10+
reading/decoding 309-6762
performance within
a compact body.
With a maximum reading distance of
1m paticularly demanding applica- Bar Code Readers - Slot
tions in terms of optical performance
can be handled with ease. Industrial Digital Bar Code Slot Reader
High reading performance
High decoding performance
ACR code reconstruction technology
Compact dimensions - 101 x 84 x 42mm
Rugged IP65 industrial case
Ideal for reading small codes at high speeds

Real time decoding


Immune to ambient light
26
Software, manuals and brackets are included with the scanners
H=28.5, W=126, D=52

Industrial Computing & PLC's 893


Applications include chemical and biomedical analysis machines, letter/document pro-
cessing machines, small/medium conveyor sorting, process control etc. HBCS7000 is an industrial digital slot reader designed to provide excellent
scanning performance on a wide variety of bar coded cards and badges
Scan rate 400 to 1000 scan/s Weight 800g Operates in the visible red (660mm) with a resolution of 0.19mm
Reading range 100 to 1000mm Case material Cast aluminium
Wide scan speed range and the extra depth of field allows a slot width of 3.2mm
Max. reading width 700mm Power supply 10 to 30V dc
Max. resolution 0.3mm The digital output is compatible with TTL and CMOS logic.
OC317
Light source Visible laser diode (650nm)
Decoder type Built-in Price Each
SAT429
Order Code 1+ 10+ 50+
178-599
Price Each
Mftrs. List No. Order Code 1+ 3+ 5+
Laser scanner DS4600-3101 314-1780
1002 Metallic Barcode Slot Reader
Aluminium housing for
Controller/Data Concentrator harsh environment application
Choice of light source Red/Infra Red
The unit has been designed
TTL data output with AMP DB9 female con-
for high speed data collection
nector
in a multi-drop network of
Compatible with the 131 Tiny Decoder
Datalogic bar code readers.
Through the unit, a mult-station reading system
or a single reading station in a multi-head con-
figuration for 360 deg. reading around the con-
veryour, can be realised in a very simple way.
The unit collects data, controls the status of the Optical:
reader and elaborates statistics. Light Source: Infra-Red (940nm)/Red (660nm)
Features include: Resolution: 0.15nm
High speed data collection and transmission Card Thickness: 0.5 - 1.5mm
Up to 32 reading stations Minimum PCS: 0.5
2 serial interfaces for connection to the host Scanning Speed: 100 - 1000mm/sec
Scanning Position: 9mm from slot bed
RS485 for data collection
Remote scanner control and set up Environment:
Temperature (operating) 0 to 40 degree Celsius
Complete network monitoring Temperature (storage) -40 to 60 degree Celsius
Backlit display and keypad for programming Humidity: 5 - 95% (non-condensing)
Rugged industrial housing Electrical:
Applications include parcel sorting systems, material tracking systems, work-in- Voltage: 5V 10%
progress control and quality control. Current: 35mA (typical), 50mA (maximum)
Physical:
Power supply 10 to 30V dc Display Backlit LCD, 20 characters Dimension: 91L x 33H x 36W (mm)
Max. consumption 6W x 4 lines Weight: 252g (cable not included)
Host standard interface Programmable Dimensions 240x200x66mm OC549
RS232/RS485 polled Weight 1.95Kg
non polled/20mA C. Case material Aluminium Price Each
L./Up to 115K bauds Operating temp. 0 to 55 deg C Description Type Order Code 1+ 5+ 10+
Auxiliary interface RS232/up to 19.2 Kbauds Protection class IP58 Red 1002W-RA9 309-7055
Infra-Red 1002W-IA9 309-7067
continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 893
Industrial Computing & PLC's
Max. resolution 0.12mm Weight 270g
Bar Code Readers - Slot continued Scan rate 36+/-3 scan/s Case material ABS and polycarbonate
Print contrast 15% Cable length 2m
1022 Plastic Barcode Slot Reader ratio (min)
Available in a Reading distance 800mm Laser class Class 2 (IEC 825-1 and DCRH)
Decoder Masked single Operating -10 to 50C
choice of light chip decoder, temp.
sources Red/Infra-red 25MHz Protection Sealed against dust and rain
1022W Plastic housing with TTL data Reading indicators Laser on, good read,
output beeper
1022R Plastic housing with RS232 data Reading angle
output Skew +/-60
1022K Plastic housing with PC key- Pitch 5 to 55C, -5 to 55
Tilt +/-20
board output
SAT432
Reads security card laminated
obscured barcodes, use Infra-red light Mftrs. Order Price Each
source List No. Code 1+ 5+ 10+
Optical:
Light Source: Infra-Red (940nm)/Red (660nm) Scanner DLL6010-M1 314-1809
Resolution: 0.15nm Cable & Accessories
Card Thickness: 0.5 - 1.5mm PS/2 wedge, coiled CAB365 314-1822
Minimum PCS: 0.5 PS/2 wedge, straight CAB321 314-1834
Scanning Speed: 100 - 1000mm/sec
Scanning Position: 11mm from slot bed
RS232 9 pin female, coiled CAB362 314-1846
RS232 9 pin female, straight CAB327 314-1858
Environment:
Temperature (operating) 0 to 40 degree Celsius
Power supply PG5E 314-1860
Temperature (storage) -40 to 60 degree Celsius System manual 90ACC1460 314-1810
Humidity: 5 - 95% (non-condensing)
Electrical:
Voltage: 5V 10% Hand-Held Laser Scanners Cordless
Current (1022W): 35mA (typical), 50mA (maximum)
Current (1022K/R): 50mA (typical), 70mA (maximum) Integral Amplifier
Physical: The DRAGON cordless laser gun allows
Dimension (1022W/K/R): 90.4L x 28.4H x 37.2W (mm) operators to be free of cable while work-
Weight (1022W): 89g (cable not included) ing up to 50m from the base station. It
Weight (1022K): 130g (cable not included) communicates using a low power, licence
Weight (1022R): 144g (cable not included) free radio in the 433MHz band. Equipped
Type Description with bi-directional communications
1022W-IB9F TTL output, Infra-Red light source, DB 9-pin female connector between the base station and the host
1022W-RB9F TTL output, Red light source, DB 9-pin female connector they transmit the code and receive confir-
1022K-ID5Y K-B Wedge for IBM PC AT, Infra-Red light source, DIN-5P Y type cable mation of a correct reading in real time.
1022K-RD5Y K-B Wedge for IBM PC AT, Red light source, DIN-5P Y type connector
1022K-IM6Y K-B Wedge for IBM PC PS2, Infra-Red light source, Mini DIN-6P Y type cable
1022K-RM6Y K-B Wedge for IBM PC PS2, Red light source, Mini DIN-6P Y type connector Supports 2 types of use:
1022R-IB25 RS232, Infra-Red light source, DB-25P female connector Point to point: each gun is associated with its own base station
1022R-RB25 RS232, Red light source, DB-25P female connector Multipoint: many guns (up to 32) transmit data to base station
OC550
Communication is through an integrated multistandard decoder interface (con-
26 Type Order Code 1+
Price Each
5+ 10+
neciton possibility through RS232, Wedge, Pen)
Robust yet light weight (340g)
Point to point and multipoint transmission managed though SW in a single radio
1022W-IB9F 309-7079 channel
1022W-RB9F 309-7080
Industrial Computing & PLC's 894

Base RF station with smart battery charger


1022K-ID5Y 309-7092 Smart battery charger for multipoint applications
1022K-RD5Y 309-7109 Immune to light exposure in offices and facilities, and direct exposure to sunlight
1022K-IM6Y 309-7110
1022K-RM6Y 309-7122 Applications include warehouse management, shipping and receiving, inventory contr-
1022R-IB25 309-7134 rol, work-in progress control, cash and carry and retail applications, fork lifts etc. The
1022R-RB25 309-7146 freedom of movement afforded by the scanner leads to enhanced levels of productivity,
making jobs easier, faster and smoother.
Note: Cables are common for both corded and cordless scanners,
Barcode Readers - Hand-Held FOR POWER SUPPLY, SEE ORDER CODE 314-1779, PAGE 893
Hand-Held Laser Scanners Corded Light source Visible laser diode, 670nm Dimensions 203x117.2x68.9mm
Maximum resolution 0.12mm Weight 340g
An industrial hand-held laser gun designed Scan rate 36 +/- 3 scan/s Case material ABS and polycarbonate
to work reliably and consistently in harsh Print contrast ratio 15% Laser classification Class 2 (IEC 825-1
operating environments. CDRH)
Reading distance 800mm Operating temp. -10 to +40C
Reading indicators Laser ON, Good Read/ Protection Immune to water and
Good Transmission, Beeper dust
Bar codes 2/5 family, code 39 (plus Base station Power supply 10 to
code 32, CIP39) EAN128, 28V dc
EAN/UPC, code 93, code Dimensions 185x115
128, CODABAR x104mm
Features include: Radio Interfaces RS232, Wedge, Pen
Clearly audible dual bleepers and bright good read LEDs Operating range Up to 50m Battery recharging 2 hours
Optical parts completely suspended on shock absorbers to prevent mis-alignment Operating frequency 433.05-434.79 MHz
after repeated knocks Radio power <10mW
Autonomy Over 60,000 scans with
Composite material body to prevent damage from falls up to 2m NiMH batteries
Multi-standard decoder (RS232, Wedge and Pen emulation SAT433
General purpose - suitable for most common applications
High-resistance cables and connections Mftrs. Order Price Each
Trigger resists more than 1 million hits List No. Code 1+ 3+ 5+
Working temperature -10C to +50C Laser gun DLL6010-RNM 314-1871
Immune to light exposure in office and facilities and direct exposure to sunlight Base/charger OM6010-R 314-1883
System manual 90ACC1550 314-1901
Application include industrial data collection, inventory control, quality control, auto-
mated warehouses, delvery control etc.
Note: Cables are common for both corded and cordless scanners
Power supply 4 to 20V dc Barcodes 2/5 family, Code 39, Code 128, EAN 8,
Consumption
Light source
170mA @ 5V
Visible laser diode, Interfaces
EAN 13, EAN/UPC
RS232, Wedge (PC IBM AT/PS2, IBM
Scheduled Deliveries
670nm terminals:
31xx, 32xx, 34xx, 37xx, 3153), pen
emulation
Save money by scheduling your
Dimensions 203x117.2x68.9 requirements for up to 12 months.
Order now on (65) 788 0200.

894 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Cipher Lab Handheld Barcode Scanners 1240 Laser Scanner
Excellent optical performance Visible laser diode at 670nm
Non contact reduces barcode wear 36 scans per second
Built in multi-function decoder allowing 15 different symbologies to be read Typical depth of field 30cm for 15 Mil element width
All interfaces are cable selectable, cable not supplied Minimum print contrast 20% absolute dark/light
Low power consumption reflectance at 670nm
"Good read" indicator and tone bleeper Mechanical durability, 1.5m drop onto a concrete sur-
Available in 67mm/90mm read head width CCD's and Long range laser, allowing a face
wide range of barcode formats to be scanned

Advanced Data Editing and Programmable Features


1021 Plus, 1067, 1090, 1240, 1045, 1023 (T2, T12, T123)
OC564 OC548
Symbology Support Code 39/Full ASCII UPCE
Italy Pharma Code UPCE with ADDON2/5 Price Each
French Pharma Code Codabar Order Code 1+ 5+ 10+
Industrial 2 of 5 Code 93
Interleave 2 of 5 Code 128 309-6804
Matrix 2 of 5 MSI
EAN8 Plessey
EAN8 with ADDON2/5 UPCA
EAN13/UPCA UPCA with ADDON2/5
EAN13/UPCA with ADDON2/5 * Optional Interface cables for 1021, 1067/1090 & 1240 Laser
Programmable Features Code-ID, Prefix Code, Code Length, Buzzer Volume & frequency, Scanners.
Barcode Type, Scanning mode, ISBN/ISSN/CLSI/UK & Plessey conversion, OC560
Keyboard layout, Intercharacter Delay, Language type, Time-out,
Communications parameters, Transmission mode & Character replace- Order Price Each
ment, etc. Description Code 1+ 5+ 10+
Data Editing Mode Following conditions can be programmed: Code Type, Data
length, string matching and Location CABLES - Keyboard Wedge
Data can be divided into six fields 2m straight cable DIN-5P, Y type con-
Five additional fields can be programmed for each editing for- nector for IBM PC/AT........................... 309-6816
mat, up to three editing formats can be support 2m straight cable Mini-DIN-6P, Y type
User programmable field transmission sequence connector for IBM PS2 ........................ 309-6828
Language Support for PC/AT English (US/UK), French, Italian, Belgium, Norwegian,
keyboard Layout Swedish, Spanish, Portuguese & German
2m straight cable Mini-DIN-4P, Y type
connector for Macintosh (ADB)........... 309-6830
CABLES - Serial RS232
1067/90 Scanner 2m straight cable DB-25 pin female con-
nector with DC jack.............................. 309-6841
2m straight cable DB-9 pin female con-
nector with DC jack.............................. 309-6853
3m straight cable Dual DB-25 pin male
& female connectors for terminals ...... 309-6865
CABLES - WAND EMULATION
2m coiled cable AMP-9 pin female con-
nector .................................................. 309-6877
2m straight cable with USB male connector
26
with drivers for Win95/98 & Imac............. 309-6889

Industrial Computing & PLC's 895


CABLES - 5V Power Source for scanners
Power Splitting cable for Din5P, T type
High performance coupled with an ergonomic design for IBM PC/AT Keyboard Port .............. 309-6890
Advanced optics will scan high density laminated and coloured labels Power Splitting cable for MiniDin6, T
100 scans/sec barcode scan rate type for IBM PS2 Keyboard Port.......... 309-6907
1067 with 67mm read head width
1090 with 90mm read head width continued
Low current <35mA
Optical Sensor 2048 Pixels
Light source Red 660nm
OC558

Price Each
Type Order Code 1+ 5+ 10+
1067 309-6786 Need an Extra Catalogue?
1090 309-6798
If so, call us on (65) 788 0200
1021 Plus Scanner or e-mail singapore-sales@farnell.com
Durable, ideal for demanding
applications, Epos and inventory
control
Low cost
80 scans/sec barcode scan rate
67mm read head width
Depth of field 1-10mm

Ex-stock Products
OC557

Price Each The worlds largest choice of


Order Code 1+ 5+ 10+
309-6774
electronic and industrial products
available worldwide for same day despatch.

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 895
Industrial Computing & PLC's
Barcode Readers - Hand-Held continued Barcode Readers - Pen
Bar Code Scanner Handheld COMTECH Smart Wand Bar Code Reader
CCD Bar code
scanning wand with an integrated
decoder
Automatically decodes 9 bar code sym-
bologies
Low current draw
Medium resolution
Programmable by bar code labels or by
escape sequences
Configurations stored in non-volatile memory CMOS/TTL interface
Metal housing 9 pin male D connector
Bar Code Symbologies Code 39 - standard or extended Codabar
Interleaved 2 of 5 Code 11
Excellent optical performance Low power consumption Code 128 MSI code
Non contact readability reducing bar code wear UPC A, E Code 93
Built in decoder allowing 11 different symbologies EAN 8, 13
Good read indicator and tone bleeper Bar code programmable CMOS/TTL Interface Resolution
60mm and 80mm read heads offering wide read window Output 0 to 5V Medium 0.19mm
CT10U Scanner (Order Code 648-450) Input Up to 15V
OC111
Scanner features:
Full cable format programmability Fast scan rates of 100 scans/sec Price Each
Interchangeable interface quick disconnect Not supplied with cables Mftrs. List No. Order Code 1+ 10+
Enhanced decoder software HBSW-8300 574-247
CT10U Cable Options
CT10U Scanners are not supplied with a cable kit. Cable kits should be chosen from the list below
and purchased in addition to the CT10U Scanner. Low Current Bar Code Wand
Host Hardware Interface
Cable Format IBM PC/AT IBM PS/2 Apple Mac Terminal
Keyboard Wedge 648-395 648-401 648-413
Serial RS232C 648-425 648-425 648-449
Wand emulation 648-437

CT22 Scanner
Scanner features:
Low cost scanner 50 scans/sec scan rate
Dedicated output Non replaceable cables Low continuous current draw High ambient light rejection
Supplied as kit including cables Sealed tip 0.19mm resolution
Scan angle: 0C to 45C typical

26 CT22 Kits
Each scanner has non detachable cables and therefore scanners and cable are supplied in a kit for-
mat. The table below shows cable options available.
HBCSA300 Additional features
Rugged polycarbonate body Dust and water resistant
15kV ESD isolation Digital output-TTL/CMOS compatible
Host Hardware 25kV immunity 5 pin 240 Din connector
Industrial Computing & PLC's 896

Cable Format IBM PC/AT IBM PS/2 Environmentally sealed


OC122
Keyboard wedge 648-371 648-383
Serial RS232C 648-360 648-360 Mftrs. Price Each
List No. Order Code 1+ 10+ 50+
CT10T Laser Emulation Kit (Order Code 648-462)
HBCS-A300 178-591
Scan rate of 100 scans/sec Kit includes scanner and output cables
Optical Resolution: 0.1mm CCD 2048bits
Depth of Field: 0-50mm
Print Contrast Signal: 90% (typical contact code 39) Barcode Decoders
Light Source: Visable LED
Scanning Speeds: CT10+=200 scans/sec Bar Code Decoder IC
CT10=100 scans/sec Single Chip
CT22=50 scans/sec
Scanning Width: 60mm (80mm on CT22 Series) Flexible, automtatic code recognition
Supply Voltage: 5V 10% Supports 5 Industry Standard Bar Code symbologies
Power Consumption: Typically 160mA operating Choice of parallel or full duplex serial ASCII inteface
Operation Temp.: -20C to +60C Programmable via escape sequences or pin strapping
Humidity: 20% to 85% non condensing Audio and visual feedback control
Body Material: ABS Plastic
Weight: 150g
IC automatically reduces power consumption when not scanning
Cable Length: 1.5m (straight) Operates with any Hewlett Packard digital barcode wand
Readable Codes: Code 39 full Ascii, Code 39, Interleaved 2 of 5 UPC A, Bar Code Symbologies: Code 39 - standard or extended EAN/JAN 8, 13
UPC E, EAN/JAN 8, EAN/JAN13, Codabar, Code 128, Interleaved 2 of 5 Codabar
Code 11, Code 93 (option) UPC A, E0, E1 Code 128
OC444
Power supply: +5V dc Current draw: 24mA
Price Each OC116

Order Code 1+ 3+ 10+ Price Each


CT10U Scanner 648-450 Mftrs. List No. Order Code 1+ 10+
HBCR-1610 499-742
648-395
648-413
Cable options for 648-425
CT10U Scanner 648-449 HEDS3000 Accessory
Laser emulation kit OC249
(CT10T) 648-462
CT22 Kits 648-360 Mftrs. Price Each
648-371 List No. Order Code 1+ 10+ 100+
648-383 Opto-reflective sensor HBCS1100 308-547

896 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
131 Tiny Decoder Magnetic Card Swipe Reader
Reader input port accepts Track Two with RS232 Output
TTL/Wand barcode data output Swipe reader has RS232 interface built
Dual track ISO7811 Clock/Data magnetic slot reader into main body of reader
output Reads track two of any ISO standard
Advanced data editing and format programming card, maximum 40 characters
modes supported Cards can be swiped in either direction
Cable selectable data interfaces, RS232 & PC RS232 serial data output is through a
Keyboard Wedge 2m cable via RS232 connector to a PC
Multiple decoder maybe networked to a single PC Power is taken from the computers ser-
RS232 or keyboard wedge port ial port
Compatible with the FEC HP Wand and Slot reader Any terminal emulation program can be
products, may require connector change used to present data on host computer
For suitable cables see page 309956 Reader transmits fully buffered card
Dimension 82mm (L), 57mm (W), 22mm (H) data as ASCII chatacters
Weight 66g excluding Interface Cable H=41, W=110, D=43 Transmission protocol set as 9600
Power Supply 5VDC 5% baud, 8 data bits, no purity and 1 stop
Current Consumption 34mA, excluding external device bit
Housing ABS/Grey ISO standard 7811
OC565 Weight 250 grammes
Operating temperature -5C to +55C
Price Each Power supply 5Vdc, 25mA maximum
Order Code 1+ 5+ 10+ Connector 9-way Female D-type RS232
309-6919 Card feed speed 100 to 1,500mm/sec
Data output RS232 serial
Read error rate 1/1000 passes maximum
PLC153

Magnetic Strip Readers/Encoders Price Each


Magnetic Card Swipe Reader Mftrs. List No. Order Code 1+ 5+ 10+ 25+
Track Two with TTL Output 3S4YR-HSR4-RS232 737-380

Magnetic Card Swipe Reader


Track Selectable with TTL Output
Magnetic card swipe read-
er for reading a single
track, either track 1, 2 or 3
Cards can be swiped in
either direction, with TTL data output
Microswitch allows BPI to be set to either
H=32, W=100, D=32.5 75 or 210 depending on track
Snap-on white plastic housing can be
Magnetic card swipe reader for reading track two of any ISO standard card

Numeric data can be read off the card, upto a maximum of 40 characters
Cards can be swiped in either direction
H=24, W=90, D=24
removed without tools
Mounting holes allow front or reverse 26
ISO standard 7811 mounting to the host device, keyboard etc.
TTL output data is through a 250mm five way cable (supplied)
Weight 40 grammes
Black plastic cover can be removed if required

Industrial Computing & PLC's 897


Operating temperature -10C to +55C
Two M3 mounting holes allow reader to be attached to host device, keyboard etc.
Power supply 5Vdc, 3mA maximum (CMOS)
ISO Standard 7811 PCB circuit Amplifier and F2F decoder
Weight 90 grammes Connector Solder points on PCB
Operating temperature -10C to +55C Card feed speed 100 to 1,200mm/sec
Power supply 5Vdc, 25mA maximum Data output TTL Logic (Data/Clock pulse)
PCB circuit Amplifier and F2F decoder Read error rate 1/1000 passes maximum
PLC149
Connector IL-55-S3L (JAE) socket housing, 5 way
Card feed speed 100 to 1,500mm/sec Price Each
Data output TTL logic (data/clock pulse)
Mftrs. List No. Order Code 1+ 5+ 10+ 25+
Read error rate 1/1000 passes maximum
PLC152
3S4YR-HNR4U 737-392
Price Each
Mftrs. List No Order Code 1+ 5+ 10+ 25+
Magnetic Card Insertion Reader
3S4YR-HSR4 737-379
Track Two with TTL Output

Magnetic Card Swipe Reader


Track Two with RS232 Output
Manual swipe card reader with RS232
interface
Low power consumption due to CMOS
technology
1.5m connection cable
Bi-directional read capability H=21.5, W=60, D=87

Allows the reading of track two of any ISO standard magnetic stripe card
ISO Standard 7810, 7811/1-5, 7812, 7813 Data can be read as the card is inserted or withdrawn, TTL data output
Card feed speed 20 to 100cm/s
Two microswitches sense card upon insertion, reading 62% of data track
Service life 300,000 passes minimum
Operation temperature 0 to 45C Three M3 fixing holes provided for easy mounting
Ideal for either logic or physical access control applications
H=35, W=100, D=38
PLC181
ISO standard 7811
Weight 50 grammes
Price Each
Operating temperature -10C to +55C
Mftrs. List No Order Code 1+ 5+ 10+ 25+ Power supply 5Vdc, 25mA maximum
354YR-HNFR4 565-210 PCB circuit Amplifier and F2F decoder
Connector IL-10S3L-(N) (JAE) Socket housing, 10 way
Card feed speed 100 to 1,000mm/Sec
Track read 62% or 46.6mm maximum
Data output TTL logic (Data/Clock pulse)
PLC148

Price Each
Mftrs. List No. Order Code 1+ 5+ 10+ 25+
3S4YR-SBR4-20 737-409

continued

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 897
Industrial Computing & PLC's
Magnetic Strip Readers/Encoders continued Landing Contact Eight Pin Smart Card Connector
Insert Magnetic/IC Card Reader

H=13.5, W=60, D=78

Allows the reading/writing of all middle position ISO 7816 cards


The eight contacts land on the card as it reaches the back of the device
Serial communication is achieved through FPC cable
H=25, W=76, D=126 FPC cable is solder connected to pins and card sensing microswitch
Three M3 fixing holes provided for easy mounting
Ideally suited for applications using hybrid magnetic stripe and IC card (such as
EMV) ISO standard 7816
Red and green LEDs for operation indicator Weight 40 grammes
Operating temperature -25C to +75C
Solenoid controlled IC card locking mechanism Contact pin Eight phosphor bronze wire
Reads track two, TTL data output Contact pin life 500,000 card insertions
Interface cable FPC 10 way, 40mm length
Magnetic card type ISO 7810-7813
Connector Recommended Molex 52207-10990
IC card type ISO 7816-1-2 PLC151
Operation temperature 0 to 45C
Service life Magnetic head 300,000 passes Price Each
IC contact 500,000 passes Mftrs. List No. Order Code 1+ 5+ 10+ 25+
PLC182
3S4YR-SCR-OJ-002 737-410
Price Each
Mftrs. List No Order Code 1+ 5+ 10+ 25+
3S4YR-SGR4J 565-258 1023 Magnetic Card Reader

Insert Magnetic/IC Card Acceptor


with RS232 Output

Reads ISO7811 magnetic stripe cards, choose from 3 different models track
2, track 1 & 2 and track 1, 2 & 3
Cable selectable data interfaces, RS232 & PC Keyboard Wedge
26 Bi-directional card reading supported
Dimension: 150mm (L), 43mm (W), 45m (H) Power Supply: 5VDC 5%
Weight: 180g excluding Interface Cable Current Consumption: 35mA Max.
OC552
Industrial Computing & PLC's 898

Ideal for applications using magnetic and IC cards Price Each


Conforms to EMV specification Type Order Code 1+ 5+ 10+
Card locking mechanism protects data while communicating with host system 1023-T2 309-6920
One RS232 port handles data from both magnetic and IC cards 1023-T12 309-6932
ISO standard ISO 7810, 7811-1 to 5, 7816-1 and 2 1023-T123 309-6944
Operation temperature 0 to 40C
Service life Magnetic head 300,000 passes (min)
IC cards 500,000 (min)
Data length 8 bit
1036 Manual Hi/Lo Card Reader Writer
PLC183

Price Each
Mftrs. List No Order Code 1+ 5+ 10+ 25+
V4AF-1J-01V 565-246

Motor Driven Magnetic Card Reader


Compact size and light weight allows
easy installation in any terminal
Heavy duty construction
High speed card feeding Read/Write magnetic stripe cards conforms to ISO 7811/1-5
Reads track two, TTL data output RS232 interface, can be ASCII command driven by third party application
Write and data verify simultaneously in one swipe of all three ISO tracks 1, 2 & 3
Supports both high and low coercivity magnetic stripe cards
User defined card formats supported
Supplied with fully featured PC DOS/Windows software utilities
Complete package includes encoder unit, software, manuals, interface cable and
power supply
H=62, W=90, D=122 Ideal for membership, loyalty and security card applications
ISO standard ISO 7810, 7811/1-5, 7812, 7813 Feature Specification
Operation temperature -5 to 55C
Card:
Service life 1,000,000 magnetic head
Read Track 1 & 3 210bpi (Bits per Inch)
Card feed speed 40cm/s
Track 2 75 or 210bpi
Motor type dc motor Bits per Character 5 to 7
PLC184
Media Speed Reads 5 - 50 ips for ISO tracks
Price Each Media Thickness 0.76 - 1.2mm
Jitter Read bit to bit interval <15%
Mftrs. List No Order Code 1+ 5+ 10+ 25+ Write bit to bit interval <10%
3S4YR-MCR4-N-02 565-234 Head life 500,000 swipes for both magnetic read/write
MTBF 45,000 hours
Standard ISO7811
Power Supply External power pack 24V/1.8A DC regulated

898 Electronic, Electrical and Mechanical Prices are in Singapore Dollars and exclusive of GST
Industrial Computing & PLC's
Feature Specification
Mechanical:
Body ABS 94VO
Dimensions 60H x 65W x 210L mm
Weight 1.5Kg
Interconnection RS232 cable, RJ45 -> DB9F, 5 feet
Environment:
Operation -10 to 60 degree Celsius
10 to 80% humidity, non condensing
Storage -20 to 70 degree Celsius
10 to 90% humidity, non condensing
OC553

Price Each
Order Code 1+
309-7043

Optional I/F cables for 1023 MSR, 1045 Fixed CCD Scanner &
Tiny Decoders
OC563

Order Price Each


Description Code 1+ 5+ 10+
1.2M straight cable, DIN5 for PCAT ........ 309-6956
1.2M straight cable, Mini-DIN6 for PS2,
PS55, PCAT ......................................... 309-6968
1.2M straight cable, Mini-DIN6 for
Macintosh............................................ 309-6970
1.2M straight cable, Female DB9 for
RS232 single port operation................ 309-6981
1.2M straight cable, DB25 connectors for
RS232 dual port operation for terminals 309-6993
1.2M straight cable, Phonejack 10P10C
for Aux RS232 port on Tiny III, DB9
Female connector for RS232 interface 309-7006
1.2M straight cable, Phonejack 10P10C for
Aux RS232 port on Tiny III, DB9 Female
connector for RS232 input device............ 309-7018
1.2M straight cable, two Phonejack
10P10C connectors, for Tiny III
cloning transmission ........................... 309-7020
1.2M straight cable, Phonejack 10P10C
connector and DB15 male connector,
for Tiny III networking ......................... 309-7031 26

Industrial Computing & PLC's 899


Free Same Day Delivery
For orders received before 12.30pm
we provide free same day delivery.

Internet www.farnell.com Sales Tel (65) 788 0200 Sales Fax (65) 788 0300 899
Industrial Computing & PLC's