Академический Документы
Профессиональный Документы
Культура Документы
Q. 1 A capacitive motion transducer circuit is shown. The gap d between the parallel
plates of the capacitor is varied as d ^ t h = 10-3 61 + 0.1 sin ^1000pt h@ m . If the value
of the capacitance is 2 pF at t = 0 ms , the output voltage V0 at t = 2 ms is
(A) p mV
2
(B) p mV
(C) 2p mV
(D) 4p mV
Q. 2 A strain gauge is attached on a cantilever beam shown. If the base of the cantilever
vibrates according to the equation x ^ t h = sin w1 t + sin w2 t , where 2 rad/s < w1 ,
w2 < 3 rad/s , then the output of the strain gauge is proportional to
(A) x
(B) dx
dt
2
(C) d x2
dt
d ^x - y h
(D)
dt
Q. 3 A dynamometer arm makes contact with the piezoelectric load cell as shown. The
g -constant of the piezoelectric material is 50 # 10-3 Vm/N and the surface area
of the load cell is 4 cm2 . If a torque t = 20 Nm is applied to the dynamometer,
the output voltage V0 of the load cell is
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
(A) 4 V (B) 5 V
(C) 10 V (D) 16 V
gD g
(C) 1 (D) 1
2 p V 1/3 p D
Q. 6 The translation S of the spot of laser light on the photodetector when a force of
F = 1 N is applied to the cantilever is
(A) 1 mm (B) 3 mm
(C) 6 mm (D) 12 mm
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 18 Poissons ratio for a metal is 0.35 Neglecting piezo-resistance effect, the gage
factor of a strain gage made of this metal is
(A) 0.65 (B) 1
(C) 1.35 (D) 1.70
Q. 19 The diameters of 10000 ball bearings were measured. The mean diameter and
standard deviation were found to be 10 mm and 0.05 mm respectively. Assuming
Gaussian distribution of measurements, it can be expected that the number of
measurements, it can be expected that the number of measurements more than
10.15 mm will be
(A) 230 (B) 115
(C) 15 (D) 2
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 23 The velocity v (in m/s) of a moving mass, starting from rest, is given as dv = v + t .
dt
Using Euler forward difference method (also known as Cauchy-Euler method)
with a step size of 0.1 s , the velocity at 0.2 s evaluates to
(A) 0.01 m/s (B) 0.1 m/s
(C) 0.2 m/s (D) 1 m/s
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 25 A differential pressure transmitter is used to measure the flow rate in a pipe. Due
to aging, the sensitivity of the pressure transmitter is reduced by 5%. All other
aspects of the flow meter remaining constant, change in the sensitivity of the flow
measurement is
(A) 10.0%
(B) 5.0%
(C) 2.5%
(D) 2.2%
Q. 27 A stroboscopic system is used for measuring the speed for a rotating shaft. The
shaft has on target mark on it. The maximum strobe rate at which synchronism is
achieved is r1 flashes per minute. The next lower flash rate at which synchronism
is achieved is r2 flashes per minute. The speed of the shaft in rpm is
(A) r1 r2 (B) r1 r2
r1 - r2 r1 + r2
(C) r 22 (D) r 12
r1 - r2 r1 + r2
Q. 28 The fig. Shows the cross-sectional diagram of an orifice flow meter with an orifice
radius R. Point a is 30 R upstream while points b and c are 0.8 R and 30 R
downstream from the orifice respectively. The pressures at points a, b and c are
Pa, Pb and Pc respectively. Then
Q. 29 The values of the material constant b for thermistors P and Q are 4000 K and
3000 K, respectively. The resistance of each thermistor at 298 K is 2 kW. At 373
K the ratio of thermistor P to that of thermistor Q will be closest to
(A) 1.33
(B) 1.00
(C) 0.75
(D) 0.50
Q. 30 Four strain gauges are fixed on a cylindrical shaft to measure tourque, as shown
in the figure.
(A) P-1, Q-2, R-3, S-4 (B) P-1, Q-3, R-2, S-4
(C) P-3, Q-1, R-2, S-4 (D) P-2, Q-1, R-3, S-4
Q. 31 The range of angular displacement (in radians) this system can measure is
(A) - I to + I (B) - I to + I
8R 8R 4R 4R
(C) - 3I to + I (D) - I to + I
4R 4R R R
V /V
Q. 32 The sensitivity 0 i is
Dq
(A) inversely proportional to R and I
(B) inversely proportional to R and directly proportional to I
(C) directly proportional to R and I
(D) directly proportional to R and inversely proportional to I
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 35 The speed of a gear having 60 teeth is measured using a proximity sensor. The
output of the proximity sensor is fed to a counter with a gating of 1s. The counter
indicates a value of 120. The speed at which the gear is rotating is
(A) 60 rpm (B) 120 rpm
(C) 600 rpm (D) 1200 rpm
Temperature (cC) 0 10 20 30 40 50 60 70 80 90
Output (mV) 35 45 55 65 75 85 95 105 115 125
(A) 13cC (B) 46cC
(C) 48cC (D) 50cC
Q. 38 A strain gauge has a nominal resistance of 600 W and a gauge factor of 2.5 . The
strain gauge is connected in a dc bridge with other resistance of 600 W each. The
bridge is excited by a 4 V battery. If the strain gauge is subjected to a strain of
100 mm/m , the magnitude of the bridge output will be
(A) 0 V (B) 250 mV
(C) 500 mV (D) 750 mV
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 39 The torque in a rotating shaft is measured using strain gauges. The strain gauges
must be positioned on the shaft such that the axes of the strain gauges are at
(A) 0c with respect to the axis of the shaft
(B) 30c with respect to the axis of the shaft
(C) 45c with respect to the axis of the shaft
(D) 90c with respect to the axis of the shaft
Q. 42 Match the essential amplifier characteristics with the sensing applications given
below :
Amplifier Characteristics Sensing Applications
P. Charge amplifier with very low bias L Strain gauge in unipolar DC
current and high input impedance. Wheatstone bridge.
Q. Voltage amplifier with low bias current M Glass electrode pH sensor.
and very high input impedance.
R. Voltage amplifier with very high N Piezoelectric sensor for
CMRR. measurement of static force
(A) P-L, Q-M, R-N (B) P-M, Q-N, R-L
(C) P-N, Q-L, R-M (D) R-N, Q-M, R-L
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Which configuration given the maximum change in resistance for this force ?
(A) P
(B) Q
(C) R
(D) All have equal change in resistance
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 47 Two sensors have measurement errors that are Gaussian distributed with zero
means and variance s12 and s22 , respectively. The two sensor measurements x1 and
x2 are combined to form the weighted average x = ax1 + (1 - a) x2, 0 # a # 1
. Assuming that the measurement errors of the sensors are uncorrelated, the
weighting factor a that yields the smallest error variance of x is
2 2
(A) 2 s2 2 (B) 2 s1 2
s1 + s2 s1 + s2
(C) s2 (D) 0.5
s1 + s2
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 56 In above Q., If the piezoelectric crystal of the probe is made of quartz (Youngs
modulus Y = 80 # 109 N/m2 , r = 2.65 # 103 kg/m3 the maximum thickness of
the crystal required to resonate at the frequency determined above, to the nearest
mm, is
(A) 1 mm (B) 2 mm
(C) 3 mm (D) 4 mm
Note that the bridge supply and the analog reference input for the ADC are derived
from the same 10 V DC source.
Q. 57 The change in capacitance for full-scale displacement is ! 5% for the capacitors.
The gain of the differential amplifier for utilization of the full range of the ADC
(which is ! 10 V ) is
(A) 10 (B) 20
(C) 30 (D) 40
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 59 Veena Contracta is the cross section where the flow area is a minimum for a
restriction type flowmeter. For an orifice meter, if d is the diameter of the orifice
opening, then the area of the vena contracta is approximately
2 2
(A) pd (B) 0.99pd
4 4
2 2
(C) 0.8pd (D) 0.6pd
4 4
Given that T1 = 300cC, T2 = 100cC and T3 = T4 = 20cC , the meter will indicate
a voltage of
(A) 11.0 mV (D) 15.4 mV
(C) 16.5 mV (D) 17.6 mV
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 62 With the position of the moving plate shown in the figure above, the value of the
capacitance C1 and C2 thus formed are
(A) C 1 = 2.14 pF, C 2 = 1.29 pF
(B) C 1 = 14.17 pF, C 2 = 21.25 pF
(C) C 1 = 339 pF, C 2 = 212 pF
(D) C 1 = 18.16 nF, C 2 = 23.2 nF
Q. 64 An accelerator has a seismic mass of 100 mg and natural frequency of 1 kHz , with
g the acceleration due to gravity, the static sensitivity of the accelerometer in
(nm/g) is
(A) 2.58 nm/g (B) 9.81 # nm/g
2
(C) 7.28 # 10 nm/g (D) 6.28 # nm/g
Q. 65 A glass plate is overcoated with a thin film as shown below. The reflectance of
the combination is monitored with a radiation of 600 nm wavelength. If ng and n f
are refractive indices of the glass plate and film material respectively with ng > n f
then reflectance reaches a minimum when the geometrical film thickness equals
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 69 In a falling-ball viscometer, the ball attains terminal velocities of 0.01 m/s for oil
A and 0.002 m/s for oil B. Assuming the oils have the same density and oil A has
kinematic viscosity of 5 # 10- 3 m2 /s , the kinematic viscosity of oil B in m2 /s is
(A) 15 # 10- 3 (B) 20 # 10- 3
(C) 25 # 10- 3 (D) 30 # 10- 3
Q. 71 A control loop structure is shown in the figure with FC, FT, TC and TT denoting
Flow Controller, Flow Transmitter, Temperature Controller and Temperature
Transmitter respectively. This loop is an example of
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 74 Figure given below shows an ultrasound flowmeter with the transducers separated
by a distance L = 25 mm with the line joining the transducers making an angle 60c
with the direction of the flow. The transit time difference between upstream and
downstream measurements is 10 ns with the sound velocity in the medium being
1000 m/s. Assuming that the size of the transducers is very small as compared to
the diameter of the pipe, the flow velocity is
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 77 A thermocouple is made using a copper and an iron wire. Its measuring junction
is kept at a temperature of 100cC and the reference junction is kept at the
ambient temperature of 30cC . The emf developed would be
(A) 700 mV (B) 1000 mV
(C) 3010 mV (D) 5300 mV
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 80 Two strain gauges, with the specifications given above are mounted on a structural
member in a push-pull configuration, connected in a bridge along with two
standard resistances, whose output is fed to an amplifier as shown in the figure.
The output voltage V0 per unit battery voltage, under maximum loading, is
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 86 For a proving ring used in a press, the value of force and its uncertainty are given
as 12355 ! 2354 N without any rounding off. If the error should be rounded off at
the maximum to two significant figures only, the value of the reading is rounded
off as
(A) 12300 ! 2300 N (B) 12360 ! 2350 N
(C) 12400 ! 2300 N (D) 12400 ! 2400 N
Q. 87 A quartz peizo-electric type pressure sensor has a built in charge amplifier. The
sensor has a sensistivity of 1 mV/Pa. It is subjected to a constant pressure of 120
kPa. The output of the transducer at steady state is
(A) 0 mV (B) 100 mV
(C) 120 mV (D) 120 mV
Q. 89 A viscous damper consists of a sliding piston and a cylinder filled with oil of
kinematic viscosity 5 # 10 - 5 m 2 /s. A damping force of 20 N is applied on the
piston and the steady state velocity reached is 10 mm/s. The damping co-efficient
of the damper is
(A) 2 Ns/mm (B) 4 Ns/mm
(C) 10 Ns/mm (D) 20 Ns/mm
Q. 90 To avoid the effect of fringing, the potential of the guard ring of a capacitance
transducer, shown in Fig. is to be made equal to
Q. 91 A device for measuring large internal diameters consists of two arms X and Y of
length 50 mm each and pivoted at A (Fig. Q.31). These are fitted with 3 equal size
rollers of diameter 10 mm. The arms are fitted with tilt sensors, which indicate
the angle of inclination of the arms with reference to the axis of gravity measured
in clockwise direction . If these angles of inclination of the arms X and Y are 90c
and 140c respectively, then the internal diameter of the measured device is
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 98 A strain gauge of resistance 120 W and gauge factor 2.0 is at zero strain condition.
A 200 kW fixed resistance is connected in parallel with it. Then the combination
will represent an equivalent strain of
(A) + 5290 mm/m (B) zero
(C) - 123.8 mm/m (D) - 300 mm/m
Q. 100 A quarts clock employs a ceramic crystal with a nominal resonance frequency
of 32.768 kHz. The clock loose 30.32 s every 23 days. The actual resonance
frequency of the crystal is
(A) 32.7685 kHz (B) 32.768 kHz
(C) 32.7675 kHz (D) 32.7670 kHz
Q. 101 A single-sensor, contact-type ultrasonic flaw detector uses a frequency of 330 kHz.
When testing a specimen, an echo from a flaw is recorded 0.05 mass after the
transmitted pulse. If the velocity of sound in the test object is 6.0 km/s then the
flaw is at a depth of
(A) 120 cm (B) 60 cm
(C) 30 cm (D) 15 cm
Q. 102 An electromagnetic flowmeter is used to measure the average flow rate of a liquid
in a pipe of diameter 50 mm. The flux density in the liquid has peak value of
0.1 T. The output from the flowmeter is taken to an amplifier of gain 1000 and
input impedance of 1 MW. If the impedance of the liquid between the electrodes
is 200 kW, then the peak value of the amplifier output voltage for an average flow
velocity of 20 mm/s is
(A) 1.365 V (B) 1 V
(C) 0.1 V (D) 0.083 V
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 104 In Ficks method of cardiac output measurement, oxygen consumption is 200 ml/
min., arterial oxygen content is 0.30 ml/ml and venous oxygen content is 0.20 nl/
ml. The cardiac output in 1/min. is
(A) 1 (B) 2
(C) 0.5 (D) 1.5
Q. 105 Which one of the following is a derived unit (NOT a basic unit) in SI system ?
(A) Candela (B) Coulomb
(C) Kelvin (D) mol
Q. 107 Which of the following flow meters has the lowest pressure drop for a given range
of flow?
(A) Orifice meter (B) Venturi meter
(C) Flow Nozzle (D) Rotameter
Q. 108 Different types of transducers and signal conditioning circuits are given below.
Match the transducer with the appropriate signal conditioning circuit commonly
used with it.
P. Thermocouple 1. DC Bridge
Q. Strain gage 2. Phase sensitive detector
R. Piezoelectric 3. Charge amplifier
S. L.V.D.T 4. Cold junction compensation
5. Instrumentation amplifier
(A) P-2, Q-3, R-5, S-1 (B) P-1, Q-5, R-2, S-3
(C) P-4, Q-1, R-2, S-5 (D) P-4, Q-1, R-3, S-2
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 110 Measurement of large external radius is possible with the help of an angle piece
and a screw gage as shown in Figure. The radius R can be expressed from the
measurement of H and q as
Q. 113 Two copper-constantan thermocouples are connected such that the two constantan
wires are joined together. The two copper wires are connected to the input of a
low noise chopper stabilized differentials amplifier having a gain of 1000. One of
the thermocouple junctions is immersed in a flask containing ice and water in
equal proportion. The other thermocouple is at a temperature T. If the output of
the amplifier is 2.050 V, the temperature T is
(A) 205c C (B) 102.5c C
(C) 51.25cC (D) 50c C
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 114 An N-type semiconductor strain gage has a nominal resistance of 1000 W and
gage factor of -100. The resistance of the gage, when a compressive strain of 100
mm/m is applied, is
(A) 900 W (B) 990 W
(C) 1010 W (D) 1100 W
Q. 115 A signal conditioning circuit suitable for a push-pull type capacitive transducer is
given in Figure. The output V0 is
(A) V- 0 = E C (B) V- 0 = E 3 C
3C C
(C) V- 0 = E C - 3 C (D) V- 0 = E C + 3 C
C +3 C C -3 C
Q. 118 For a steady flow of liquid, the float of the rotameter will remain in a particular
position when
(A) drag force is balanced by weight of the float and buoyancy force
(B) weight of the float is balanced by the drag force and buoyancy force
(C) buoyancy force is balanced by the drag force and weight of the float
(D) drag force and buoyancy together is slightly greater than the weight of the
float
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 120 A cardiac output measurement set-up uses the thermo-diluation principle. The
change in the output temperature is 7cC for 5.60 litres per minute of cardiac
output with an integration time of 10 s. For a second measurement, with all other
parameters remaining unchanged, the change in the temperature is 10cC with an
integration time of 20 s. The cardiac output in litres per minute for this will be
(A) 5.60 (B) 4.21
(C) 3.92 (D) 1.96
Q. 122 A seismic type of transducer has damping constant of 10. The transducer is
designed to measure
(A) acceleration (B) velocity
(C) displacement (D) force
Q. 124 A capillary viscometer, with known dimensions, is used for measuring dynamic
viscosity of oil. In order to obtain viscosity, it is necessary and sufficient if one
measures
(A) pressure drop across the capillary
(B) volume of fluid collected in a given time
(C) Both A and B
(D) Not only A and B but also one must ensure that the flow is laminar
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 125 The sensing element of a thermocouple at its hot junction is provided with a
shield while taking measurements in a high temperature gas. The principal reason
for providing the shield is
(A) to reduce conduction and convection errors
(B) to reduce radiation error
(C) to provide temperature compensation to the Seebeck voltage
(D) to improve air supply to the sensing element for better response
Q. 126 A pitot-static tube is used for measuring velocity of a gas, flowing in a duct. The
velocity is proportional to
(A) square root of the total pressure measured by the tube
(B) the total pressure measured by the tube
(C) difference between total and static pressures
(D) square root of the difference between total and static pressures
Q. 128 In a rotameter, used for measuring flow rate of a fluid, pa = pressure above the
float, pb = pressure below the float, A = area of float, V = volume of the float,
d1 = density of float material, d2 = density of the fluid, g = acceleration due to
gravity.
Which of the following equations describes the equilibrium of the float
(A) ^pb - pa h A = Vg ^d 2 - d1h
(B) ^pa + pb h A = Vg ^d2 + d1h
(C) ^pa - pb h A = Vg ^d2 - d1h
(D) ^pb - pa h A = Vg ^d2 + d1h
Q. 130 One method of measuring the radius of an arc ^Rh, is to allow a roller of radius
^r h to oscillate to and fro on the arc and measure the average time per oscillation
T second. The roller will then have a linear acceleration of 2g/3, where g is
acceleration due to gravity. In such an experiment, the value of radius of arc can
be found from the expression
(A) ^T 2 g/6p2h + r (B) ^T 2 g/6p2h - r
(C) ^T 2 g/6p2h (D) ^6r2 /T 2 g h
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 140 Among the bonded metal strain gauges, the foil type is more popular than the
wire type because
(A) error due to transverse strain is much less in foil type
(B) gauge factor is much higher in foil type
(C) the foil type is much more insensitive to temperature variation
(D) None of the above
Q. 141 In a gas chromatograph, the gas which cannot be used as a carrier gas is
(A) helium (B) nitrogen
(C) ammonia (D) oxygen
Q. 142 Which of the following restrictors has the highest discharge coefficient?
(A) Orifice plate (B) Flow nozzle
(C) Venturi tube (D) None of these
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
Q. 143 The characteristics of a control valve is shown in figure. The type of the valve is
**********
mywbut.com
GATE SOLVED PAPER - IN TRANSDUCER,MECH.MEASUR.ANDINDUS.INSTRU.
ANSWER KEY
TRANSDUCER, MECH. MEASUR. AND INDUS. INSTRU.
1 2 3 4 5 6 7 8 9 10
(B) (A) (B) (D) (A) (B) (B) (D) (B) (B)
11 12 13 14 15 16 17 18 19 20
(B) (B) (C) () (D) () (B) (D) (D) (B)
21 22 23 24 25 26 27 28 29 30
(A) (C) (A) (C) (B) (C) (A) (D) (D) (A)
31 32 33 34 35 36 37 38 39 40
(A) (D) (A) (D) (B) (C) (A) (B) (C) (B)
41 42 43 44 45 46 47 48 49 50
(*) (D) (B) (B) (B) (C) (B) (C) (C) (D)
51 52 53 54 55 56 57 58 59 60
(A) (C) (D) (C) (A) (B) (D) (B) () (A)
61 62 63 64 65 66 67 68 69 70
(B) (B) (B) (A) (B) (B) (D) (A) (C) (B)
71 72 73 74 75 76 77 78 79 80
(C) (C) (A) (C) (A) (B) (A) (C) (A) (B)
81 82 83 84 85 86 87 88 89 90
(B) (A) (C) (B) (D) (D) (D) (C) (A) (A)
91 92 93 94 95 96 97 98 99 100
(D) (B) (C) (B) (D) () (A) (D) (A) (C)
101 102 103 104 105 106 107 108 109 110
(D) (A) (D) (B) (B) (*) (*) (D) (*) (A)
111 112 113 114 115 116 117 118 119 120
(D) (C) (D) (B) (A) (A) (D) (B) (D) (*)
121 122 123 124 125 126 127 128 129 130
(D) (A) (C) (D) (B) (B) (A) (A) (A) (A)
131 132 133 134 135 136 137 138 139 140
(A) (C) (B) (D) (D) (D) (C) (B) (B) (C)
141 142 143
(C) (C) (A)
mywbut.com