A dd to this clause:
Crankshafts shall have integrally forged coupling hubs except when applied in a pressurised and sealed
crankcase.
[6.11.2.1]
Replaceable precision-bored shell (sleeve) crankpin bearings and main bearings shall be used. Anti-
friction bearings are not acceptable. The application of aluminium or aluminium alloys in bearings is not
allowed.
[6.11.2.2 to 6.11.2.4]
[6.11.3]
A dd to this clause:
Big-end bolts larger then M30 shall be furnished with hydraulically tightened nuts.
[6.11.4]
A dd to this clause:
Designs in which the crosshead pin is clamped in the connecting rod or designs using forked connecting
[6.11.5]
A dd to this clause:
Crankcase explosion relief valves shall have a minimum throat area of 70 mm2 for each dm3 of the gross
crankcase contents.
[6.11.5]
A dd to this clause:
Crosshead housings bolted to the crank case shall be doweled in place after the alignment and piston rod