Академический Документы
Профессиональный Документы
Культура Документы
ARCHITECTURAL SPECIFICATIONS
C. Steel Framing:
1. Steel Studs and Runners: 0.0329 inch minimum thickness of uncoated metal,
Galvanized. Hat shaped or as otherwise recommended by the manufacturer of
Fiber cements panels.
1. Steel Furring Channels: 0.0329 inch minimum thickness of uncoated metal,
Galvanized hat-shaped or as otherwise indicated.Minimum 7/8deep.
2. Steel Carrying Channels: Cold rolled steel, 0.0598 inch minimum Thickness of
Uncoated metal, minimum of 1 deep, galvanized.
3. Provide additional soffit framing and bracing for exterior locations, to resist wind
Load of 2.50k Pa for applications at ground level.for other levels,refer to Architect
For instruction.
D. Fiber Cement Panels Fiber cement panels shall be asbestos-free, fiber Reinforced cement sheets.
1. Density: Minimum 1380 kg/cum.
2. Product used as basis for selection: Hardiflex Pro,6mm thick,recessed edge for flush jointing. For joints with expansion gaps,
use square-edge Hardiflex 6mm thk.
CABINETS & DRAWERS and TABLES and ACCENT WALL where required.
D. Curtain Pelmet: thk Gypsum board painted white Finish Sizes and profiles shall be as indicated on the drawings.
1|Page
SECTION C: PLYWOOD PANTRY COUNTER UNDERSHEETING
1. Provide Factory fabricated wood door jambs and heads. Provide Profiles as shown
On door schedules.
a. Wood Species:
1) door Jambs & Heads in dry location:Tanguile Kiln Dried to 12%
Moisture content maximum.
2) Door Jammbs & Heads for Wet Locations: Yakal or Guijo, kiln dried to
12% moisture content maximum.
b.Finish.
1) Stain and lacquer finish to match wood veneer faces of doors.
3|Page
SECTION I: MIRROR GLASS
D. Glass Coating: Coat second surface of glass with successive layers of Chemically
Deposited silver, and manufacturers standard protective Organic coating to produce
Coating system that complies with FS DD-M-0041, except with salt spray test
Period extended to 300hrs. and Undercutting,discolorations,blackenin,and silver
Impairment at mirror edges not greater than 3.175mm(1/8inch).
D. Mirror edge shall be sealed after treatment to prevent chemical or Atmospheric
Penetration of glass coating.
1. Perform edge treatment and sealing in factory immediately after cutting to final sizes.
SECTION J: TILE
A. Provide bentonite waterproof strips as waterstops at structural elements, and where indicated in the drawing.
1. Between structural slabs and toilet flooring.
B. Acceptable Manufacturers:
1. American Colloid co.
2. System 7Corp.
3. Kunimine Industries.
4. Other approved equivalent by the Architect.
SECTION L: PAINTING
1. Gypsum and fiber cement ceiling:Three (3) finish coats of semi-gloss 100%
Acrylic latex paint over primer:
A. Available Manufacturers:
Acceptable Equivalent to BOBRICK PRODUCTS:
1. HCG, McKlnney/ Parker, Bradley, TOTO, or other equivalent approved by the Architect.
1. Flush Valves
a. Sloan
b. Zurn.
c. Other approved equivalent by the Architect.
a. Kindred.
b. Elkay.
c. Blanco.
d. Other approved equivalent by the Architect.
3. Faucets.
5|Page
SECTION O: LIGHTING FIXTURES
1. Downlights with compact fluorescent lighting fixture, warm white,rim in matte silver finish.
2. Decorative ceiling mounted, wall mounted, and drop lighting fixtures.
3. Other lighting fixture type as required by the Architect.
B. Lighting Fixtures:
1. Acceptable Manufacturers:
A. Description of Work
B. Acceptable Products:
1. Bticino
2. Gewiss
3. Panasonic
4. Other approved equivalent.
6|Page