BSC6900 UMTS Product

V900R014C00SPC500
Alarm Changes
Issue 02

Date 2013/05/14

HUAWEI TECHNOLOGIES CO., LTD.


Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei
Technologies Co., Ltd.

Trademarks and Permissions


and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.

All other trademarks and trade names mentioned in this document are the property of their respective holders.

Notice

The purchased products, services and features are stipulated by the commercial contract made between Huawei and the customer. All or
partial products, services and features described in this document may not be within the purchased scope or the usage scope. Unless
otherwise agreed by the contract, all statements, information, and recommendations in this document are provided "AS IS" without
warranties, guarantees or representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to
ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of
any kind, express or implied.

Huawei Technologies Co., Ltd.


Huawei Industrial Base
Bantian, Longgang
Address:
Shenzhen 518129
People's Republic of China
Web site: http://www.huawei.com
Email: support@huawei.com
Purpose
This document provides changes in alarms between different BSC6900 UMTS versions.

Intended Audience
This document is intended for:
l Field engineers
l System engineers
l Network operators
l Network planners

Structure
Change Type Describes the change type, including addition, modification, and deletion.

Alarm ID Describes IDs of the change alarms.

Alarm Name Describes names of the change alarms.

Change Describes changes in the descriptions of alarm.


Description
Impact on NBI Describes the impact of changes in alarms on the northbound interface data.
Data
Change Reason Describes change causes.
358680675.xls

Alarm Changes
from BSC6900 V900R013C00SPC500 to BSC6900 V900R014C00SPC500

Change Type Alarm ID Alarm Name Change Description

Added 20100 Reserved Alarm 1 The alarm is newly added.

Added 20101 Reserved Alarm 2 The alarm is newly added.

Added 20102 Reserved Alarm 3 The alarm is newly added.

Added 20103 Reserved Alarm 4 The alarm is newly added.

Added 20104 Reserved Alarm 5 The alarm is newly added.

Added 20105 Reserved Alarm 6 The alarm is newly added.

Added 20106 Reserved Alarm 7 The alarm is newly added.

Added 20107 Reserved Alarm 8 The alarm is newly added.

Added 20108 Reserved Alarm 9 The alarm is newly added.

Added 20109 Reserved Alarm 10 The alarm is newly added.

System Clock Reference The alarm severity is changed


Modified 20205
Source Unavailable from Minor to Major.

Failure in Locking System The alarm severity is changed


Modified 20207
Clock Source from Minor to Major.
Clock Reference Source of
The alarm severity is changed
Modified 20208 Main Control Board
from Minor to Major.
Unavailable
GE Link Between GE
The alarm severity is changed
Modified 20228 Switching Board and Service
from Minor to Major.
Board Faulty
The value PEUc is added to the
Modified 20241 Board Unavailable
Board Name parameter.
1. The value GE Link Inside the
Board Subsystem The
Boardvalue PEUc
of the is added
Alarm Causeto the
Modified 20242
Unavailable Board Name
parameter parameter.
is changed to The
board communication chips are
faulty.
Modified 20243 Board Hardware Fault
2. The values Chip Self-Check,
Service Port, Packet Switching
Unit, Logical Unit, Switching Unit
are added to the Alarm Cause
parameter.
06/22/2017 417
358680675.xls

The value PEUc is added to the


Modified 20247 Board Blocked
Board Name parameter.

The alarm severity is changed


Modified 20250 Sub-board Status Abnormal
from
Change Minor to Major.
When thedescription: Alarm Resource Item
Number of Resources Used 1. The following
parameter is set possible
to Num. alarm of
Modified 20258 Reaching Alarm Threshold causes
Change are added:
description:Processing
Network Intelligence
Specified by License The
The logical
alarm
Throughput, CPU
Communication of theof
the value OMUOperatoris
When
faulty. the Alarm Resource Item
Congestion
Index
Number of Resources Used parameter is changed Between
is set to
to Num. Subracks
NULL. of OMU is
The
added. physical memory of the
Modified 20259 Exceeding Alarm Threshold Network
is faulty. Intelligence Processing
Specified by License Description
Throughput, ofthealarm
value change
of OMU
Operatorafter
Change
The
the ejector
upgrade: description:
levers of the
Index is
values changed8K0 to
and 8K1 NULL. are Type
Clock Signal Outputs to the The
board
If one alarmarethe
of Configured
not lowered.
following Board
conditions
Modified 20274 added
Inconsistent to
2. The following
persist the Clock
with
fordescription:
5 minutes: Type
stepsThe Type of the
are added:
Backplane Faulty Change
parameter.
Board
The
Run the
bandwidth That
values DSP is OMUSRV
usage Running
External of 1pps
the islinks
added.
andin the
command
Synchronization Time The alarmwhether
Description
synchronization
to check Communication
of alarm
time
the change
abnormal
logical Failure
after
CPU is
trunk
Between group a is greater
Service Board thanand 70%. an
Modified 20276 Information Resource the
added
and
The upgrade:
to theloss
physical
packet Synchronization
memoryrate of the
over the OMU
Unavailable Alarm SCU
If the Board
Time
conform configured
Information
to the is added.
OMU boardResource type0.02%.
is
trunk group
Description is greater
of alarm than
change after
incorrect,
Status the
parameter.
specifications.
Theupgrade:
alarm Communication alarm Configured
Communication Congestion the Board
Lower Type
the ejector Inconsistent levers with
of thetheis
Added 20277 Congestion
If all backplane Between communication Subracks
Between Subracks Type
OMU of
board.the Board That is Running
generated
links between aftera the service version board and
is
3. generated
Step
upgrade. 2.b inafter alarm the version
handling
Configured board type an SCU board are faulty, the "If the
upgrade.
Added 20278 inconsistent with the type of procedures
Preventive
alarm Communication
is changed from
measures: Failure
Preventive
ETH0
None netcard measures:
or the ETH1
the board that is running Between
None
netcard
Recovery isadisconnected,
Service Boardreplace
measures:
and an
Communication Failure SCU
Recovery
or Board
securely is
measures:generated
insert the between Ethernet the
after
Added 20279 Between a Service Board If the
version communication
upgrade.
If the configured
cables
subracks foristhe ETH0
congestionboard type
netcard
before isorthethe
and an SCU Board Preventive
different
ETH1 from
netcard." measures:
thetoone "If is that
the is
output
upgrade,
None the service affected
Incorrect MAC Entries for running
message
but before
the version of thethe LST
upgrade upgrade,
OMUETH is not. the
Added 20237 Backplane Ports of the GE Recovery
The
service
commandalarm is measures:
is newly
affected
shows added.
but
that the
OMU version
You
If thecan handle the alarm
communication between by a
Switching Board upgrade
External
referring is not.
Ethernet
to the YouAdapter
alarm can handle
handling Alarm
Incorrect MAC Entries for service
the
Switchalarm board
is by ON, and
referring
perform an SCU tothetheboard
alarm
procedures
fails before after the version
Added 20238 Panel Ports of the GE Change
handling
following
The alarm
upgrade. isthe
description:
procedures
operations;
newlyupgrade, after
Replace
added. the
the or
Switching Board service
The
version
fix alarm
the is affected
OMUcable
upgrade.
Ethernet IPbut Address the version
connected
upgrade
Configuration
to is
ETH0 description: not. You
Error
netcard and ETH1 can
is handle
added.
Change
the alarm
Description by ofreferring
alarm to
change the ETH0
alarm
after
Added 20280 Board Temperature Abnormal netcard
The alarm
handling
the upgrade:
if the
File
procedures
status
is newly Lossadded. of
or both
Damage
after the is
netcard
added. and ETH1 netcard is
version
If the OMU
disconnected. upgrade. IP address
You can is
run the
Description
configured of alarm
incorrectly, change
the withalarmafter
SET
the OMUETH
upgrade: command
Modified 20720 OMU Board Fault OMU IP Address Configuration
OMU
If the is External
system Ethernet
files are damaged Adapter or
Error
Alarm reported
Switch set afterto the to clear
OFF
lost after
upgrade.
Change the OMU application
OMU IP Address the alarmdescription:
software isif installed,
the statusthe of alarm
either File
Added 20721 Preventive
1.
ETH0The alarm
netcard measures:
cause
or ETH1 is changed
netcard is
Configuration Error Loss or Damage is generated
reported after
None
from "This
disconnected. alarm is
the
when upgrade.
Recovery measures:
the communication between
If the output
Preventive message of the
measures: LST
Added 20723 File Loss or Damage If
thethe
OMUETH
1.A OMU OMU
possible and IP
command address
SCU
cause or
for is alarm
XPU
shows
this board
that
None
configured incorrectly, services
is
OMU
is disconnected"
added:
Recovery External "The
measures:
topatch
Ethernet
hot "This not are
alarm
Adapter
is is
affected
generated
Alarm but
Switch when the version
the
is OFF, upgrade is
Software Version installed
If theYou
not. system
communication
successfully."
can files
handle of the
between theperform
OMU
alarm
the OMUby
the
Modified 20733 following
Inconsistency Between OMU 2.Processing
application operations;
is added
software are for
and Host referring
and
Replace
removing tothe
an SCU/XPU/SAU
or the
fix alarm
the Ethernet
inconsistency handling
board cable is
incomplete,
procedures
disconnected." services
after the are
version affected
License Inconsistency connected
between
but the the
version to ETH0
OMU upgrade andnetcard the and
is not in
host
upgrade.
2.
The
ETH1
the Thealarm
status following
netcard severity
of hotif alarm
the isstatus
patches. handling
changed of both
Modified 20734 Between OMU and Host before
steps theadded:
are upgrade. Run You thecan LST
from
ETH0 Minor
netcard to Major.
and ETH1 netcard
handle
The
BRD Data theTable
command alarmName toby referring
check parameter
whether to
is
the disconnected."
alarm handling procedures
Data Inconsistency Between becomes
the board is of
Description invalid.
analarm It is
SAU change retained
board. Run in
after
Modified 20736 OMU and Host after
the
the DSPthe version
alarm reference
SAU upgrade.
command and has
to a
check
the upgrade:
fixed
If the value
whether logicaltheNULL CPU for
board orworks northbound
physical normally.
interface
Description compatibility.
memory of the OMU is faulty,after
of alarm change or
OMU Disconnected from
Modified 20737 the
the upgrade:
ejector levers of the OMU
Host
If the communication
board are not lowered, between
OMU
OMU
Boardboards Fault isand reportedSAU boards after the is
faulty,
upgrade. the alarm OMU
Disconnected
Preventive measures: from Host is
reported
None after the upgrade.
06/22/2017 Preventive measures: 517
Recovery measures:
None
If the logical CPU or physical
Recovery
memory of measures: the OMU is faulty, or
358680675.xls

Subrack configuration mode


Added 20742 is ineffective The alarm is newly added.
A possible cause for this alarm is
CRC Value Inconsistency in
added: "The bootrom file is
Modified 20750 Board Startup
updated on the OMU but not
loaded to the board."
The alarm severity is changed
Modified 20903 SAU Process Abort
from Warning to Minor.

E1/T1 Remote Alarm The alarm severity is changed


Modified 21203
Indication Signal from Warning to Minor.

IMA Link TX Unusable at Far The alarm severity is changed


Modified 21225
End from Warning to Minor.

IMA Group Activated Links The alarm severity is changed


Modified 21231
Insufficient from minor to Major.

IMA Group Activated Links The alarm severity is changed


Modified 21232
Insufficient at Far End from Warning to Minor.

Fractional IMA Link Remote The alarm severity is changed


Modified 21243
Failure Indication from Warning to Minor.

Fractional IMA Link TX The alarm severity is changed


Modified 21244
Unusable at Far End from Warning to Minor.

SDH/SONET LP Remote The alarm severity is changed


Modified 21260
Failure Indication from Warning to Minor.

The alarm severity is changed


Modified 21290 Optical Module Mismatch
from minor to Major.

The
The values of the Alarm
alarm severity Cause
is changed
Modified 21324 VCL CC Activation Failure parameter are changed from IP
from Warning to Minor.
PM check start failure and IP PM
check failure to Not Receive
The alarm Response,
Activation severity is changed
DSCP
Modified 21327 VCL PM Activation Failure
from Warning
Remarked by the to Minor.
Bearer Network
Equipment, Incompatibility with
VCL PM Configuration The alarm severity
the Version is changed
of the Peer End,
Modified 21328
Failure from Warning to Minor.
Activated IP PM Sessions
Exceeding the IP PM Capability of
the Peer End, Activated IP PM
Modified 21341 IP PM Activation Failure
Sessions in the sink direction
Exceeding the IP PM
The alarm severity Capability,
is changed
Backward
from MinorIPtoPM Activation not
Major.
Modified 21346 IP Connectivity Check Failure Supported by the Peer End, IP PM
The parameters BFD diagnostic
Activated
code by
is added.
The alarm the Peer End,
parameters Invalid
Invalid Packets Exceeding Others.
Packets Type, Slot No. of the
Modified 21388 The parameters IP address of are
the
Alarm abnormal port, and Port No.
local end and
newly added. IP address of the
peer end are added.
Added 21391 ARP Conflict A
Thenew value
alarm is 65536 of IP PATH ID
newly added.
parameter is added.

Adjacent Node IP Address


Added 21392 The alarm is newly added.
Ping Failure

06/22/2017 617
358680675.xls

Adjacent Node IP Path Ping Change description:


Added 21393 The
The alarm
alarm is
Low newly
SCCPadded.Setup
Failure
Success Rate is added.
Transmission Resource Pool Description of alarm change after
Added 21394 Theupgrade:
the alarm is newly added.
Ping Packet Loss
If the
Change SCCP setup success rate is
description:
loweralarm
The than SCTP
the alarm
Link threshold
IP Address
Adjacent Node IP Path The
(80%alarm is newly
by default) added.
and the number
Added 21395 Unreachable is added.
Excessive Packet Loss Rate of Connection Requests (CR) is
Description of alarm change after
greater than the minimum number
the upgrade:
The
of CRsalarm
(100is by
newly added.
default) in two is
Added 21396 IP PM Capability Exceeded If the SCTP link configuration
continuous periods
dual-homed, and the (five
onlyminutes
one
for each period),
destination Low SCCP
IP address at the Setup
peer
Low SCCP Setup Success Success Rate is reported
end is unreachable, SCTPafterLinkthe
IP
Added 21522
Rate upgrade.
Address Unreachable is reported
Preventive measures:
after the upgrade.
SCTP Link IP Address None
Preventive measures:
Added 21543 Recovery measures:
Unreachable None
If the SCCPmeasures:
Recovery setup success rate is
low
If the SCTP linkupgrade,
before the services
configuration is
Added 21580 IP Path Blocked The
are alarm
affectedis newly
but theadded.
dual-homed and the only oneversion
upgrade is not.
destination You canathandle
IP address the peer
the alarm
end is by referring
unreachable to thethe
before alarm
IP Address in Transmission handling
Added 21602 The alarmprocedures
upgrade, is newlyare
services after
added. the but
affected
Resource Pool Blocked upgrade.
the version upgrade is not. You
can handle the alarm by referring
Added 21603 Adjacent Node Congestion to
The the alarm
alarm is handling procedures
newly added.
after the upgrade.

The alarm severity


1.A possible cause is
forchanged
this alarm
Modified 22201 UMTS Cell Congested
from Warning to Minor.
is added: "The SPU sub-system or
board controlling the NodeB
becomes faulty."
Modified 22202 UMTS Cell Unavailable
2.A handling procedure step is
The correlation
added: between
"Check the statusthe ALM-
of the
22215 UMTS Cell Max
SPU sub-system or board DL Power
Modified 22206 UMTS Cell Setup Failed Mismatch
controllingand
the the ALM-22206
NodeB."
UMTS Cell Setup Failed is
removed.
UMTS Cell Reconfiguration The alarm severity is changed
Modified 22207
Failed from Warning to Minor.

UMTS Cell Common The alarm severity is changed


Modified 22208
Channel Setup Failed from Warning to Minor.
UMTS Cell Common
The alarm severity is changed
Modified 22209 Channel Reconfiguration
from Warning to Minor.
Failed
The alarm severity is changed
Modified 22212 UMTS Cell Blocked
from Major to Warning.

IMB Cell Common Channel The alarm severity is changed


Modified 22233
Setup Failed from Warning to Major.

Dual-Homed NodeB Control


Added 22236 The alarm is newly added.
Rights Inconsistency

UMTS Cell DC-HSUPA


Added 22237 The alarm is newly added.
Function Fault

06/22/2017 717
Change description:
The alarm Service Flow Control in
358680675.xlsa Cell is added.
Description of alarm change after
the upgrade:
If integrated flow control is
Added 22238 Service Flow Control in a Cell implemented in a cell before the
upgrade, this alarm will be
reported after the upgrade.
UMTS Cell Broadcast The
1. Thealarm
Preventive relationseverity between
measures: is changedALM-
Modified 22502
Service Congestion from
22214 Warning
None NodeB Unavailable and to Minor.
ALM-22234
Recovery measures: IMB Cell Setup Failed
is
Noneremoved.
Modified 22234 IMB Cell Setup Failed
2. The relation between ALM-
22204
The alarm NCPcause Faultyvalue and ALM-"The cells
UMTS Cell DC-HSDPA 22234
in the IMB
same Cell
1. The alarm cause "UMTSDC Setup
carrier Failed
group is
are
Cell
Modified 22221 removed.
Function Fault not served by
Unavailable" is added. the same SPU sub-
system"
2. The step is added.
"Check the status of
the board where the MPU sub-
Modified 22202 UMTS Cell Unavailable
system controlling
1. A relationship to the
filtercell
ALM-is
located."
22219 UMTS is
The "CCP Information addedCell to
EFACH the alarm
CCP Information handling
Function procedure.
FaultBetween through this alarm
Inconsistency
1. The correlation between the ALM-
RNC
Modified 22213 Inconsistency Between the is added.
and the NodeB"
22214 NodeB Unavailable alarm detection type is
RNC and the NodeB 2. A relationship to filter ALM-
added.
and ALM-22206 UMTS Cell Setup
22222
Failed is UMTSremoved. Cell ERACH
Modified 22206 UMTS Cell Setup Failed Function Fault through this ALM-
alarm
2. The correlation between
is added.
22204 NodeB Unavailable alarm
3. A ALM-22206
relationship to filter Cell
ALM-Setup
UMTS Cell HSDPA Function and 1. A relationship UMTS
to filter ALM-
Modified 22217 22223
Failed UMTS
is removed. Cell EPCH Function
Fault 22222 UMTS Cell ERACH
Fault through this alarm is added.
Function
4. Fault through
A relationship
Change description: to filterthis ALM- alarm
UMTS Cell HSUPA Function is added.
22221
ALM-21293 UMTS Cell
SDH/SONET DC-HSDPA HP
Modified 22218 1. A
Fault 2. A relationship
relationship
Function
Signal Fault
Label
to
to filter
through
Unstable
ALM-
filteristhis
ALM- alarm
added.
22222
22237 UMTS
UMTSof Cell
Cell ERACH
DC-HSUPA
is added.
Description
Change
Function description:
Fault through alarm change
this alarm
UMTS Cell EFACH Function Function
5. the Fault
A relationship
after
ALM-21294 upgrade: through
SDH/SONETto filterthis ALM-TU
alarm
Modified 22219 is
is added.
added.
Fault 22237
This
Signal UMTS
alarm Cell
Lossisisgeneratedadded. DC-HSUPA when the
2. A relationship to filter ALM-
Function
received
Description
22223 UMTSFault
higher of through
Cell order
alarm
EPCH this
path
change alarm
(HP)
Function
SDH/SONET HP Signal is added.
Change
signal
after
Fault the label
throughdescription:
byte
upgrade: C2 over
this alarm is added. the
Added 21293 ALM-21295
Label Unstable optical
This alarm port isisSDH/SONET
unstable. when
generated TU no
Multiframe
Preventive
Change Loss
measures:
description: is
signals are detected on an optical added.
Description
NonetributarySDH/SONET
ALM-21296
port of alarm change
because of aTU Type
chip
Added 21294 SDH/SONET TU Signal Loss If Change
after
Recoverythedescription:
multiple faults
upgrade:
measures: cause a path
Inconsistent
fault.
ALM-21564 is
Low added.
QAAL2 Setup
fault,
This
Since the
thisBSC
alarm
Description
Preventive alarm of reports
ismeasures:
generated
does
alarm the
not alarm
when
change affect
Success
with
the the
multiframe
upgrade, Rate loss is
highest-priority
handle added.
occurs the cause.
on an
alarm
SDH/SONET TU Multiframe after None
If
the upgrade:
Description
ALM-21581 ofPathalarm Fault change
with the
Added 21295 optical
immediately
This
Recovery port
alarm tributary
is after
generated
measures: the unit.
upgrade
when by
the
Loss after
cause the"ping upgrade:
failure" or(virtual
"AAL2 path
Preventive
referring
SS
Since bit of
this to
the measures:
the
alarm V1 alarm
byte
does online
not help.
affect
This
reset
None alarm
failure" is has
reported been when
reportedthe
container
the
MPU upgrade,
detects pointer handle
that 1)
the configured
the alarm on
following
SDH/SONET TU Type when
Added 21296 a BSCthe
Recovery
immediately
conditions board highest-priority
measures:
are differs
after
met the from
for
cause
upgradethat byis
an AAL2
Inconsistent transmission
Since this alarm fault (a
does bearing
not
configured
referring
path on to at
the the the
Iu-CS peer
alarm end.affect
online
interface help.
board fault,
the upgrade,
Preventive bearing
handle
measures: port notin a
the alarm
measurement
configured
immediatelyfault, period
after orthepath(5 minutes):
upgrade by
Modified 21581 Path Fault None
The number of successful QAAL2
unavailability
referring
Recovery to the notified
measures: alarm by OM
online fault),
help.
connection
the BSC clearssetups the divided
alarm. by the
Since
number thisof alarm
QAAL2 does not affect
connection
Low QAAL2 Setup Success If theALM-21581
upgrade, Path Fault
handle the with the
alarm
Added 21564 setup
cause requests
"ping failure" is less has thanbeen 20%.
Rate immediately after the upgrade by
The number
reported when of the
AAL2 path setup
highest-priority
referring
requests to the
is larger port alarm
than 10.online help.
cause
The is "bearing
reported information of the
Preventive
unavailable", measures:
the Intermittent
BSC clears the
alarm
None parameter
alarm
Alarm and reports
is changed ALM-21581
from "Alarm ID,
Recovery
Path Fault measures:
with the causeof"bearing
and
If location
thisnotalarm information
is reported before the an
Modified 20271 Statistical Alarm port configured".
alarm
upgrade, thatongoing
is in intermittent
services state" are
to "Alarmbut
affected ID,the Alarm upgradeNameisand not
location
affected.information
Since this alarm of the doesalarmnot
that
affectis the
in intermittent
upgrade, handle state."the
alarm immediately after the
upgrade by referring to the alarm
online help.

06/22/2017 817
358680675.xls

Modified 22201 UMTS Cell Congested The RNC ID parameter is added.

Modified 22202 UMTS Cell Unavailable The RNC ID parameter is added.

UMTS Cell Common


Modified 22203 The RNC ID parameter is added.
Channel Faulty

Modified 22206 UMTS Cell Setup Failed The RNC ID parameter is added.

UMTS Cell Reconfiguration


Modified 22207 The RNC ID parameter is added.
Failed

UMTS Cell Common


Modified 22208 The RNC ID parameter is added.
Channel Setup Failed

UMTS Cell Common


Modified 22209 Channel Reconfiguration The RNC ID parameter is added.
Failed

UMTS Cell Information


Modified 22210 The RNC ID parameter is added.
Exchange Failed

Modified 22212 UMTS Cell Blocked The RNC ID parameter is added.

UMTS Cell Max DL Power


Modified 22215 The RNC ID parameter is added.
Mismatch

UMTS Cell HSDPA Function


Modified 22217 The RNC ID parameter is added.
Fault

UMTS Cell HSUPA Function


Modified 22218 The RNC ID parameter is added.
Fault

UMTS Cell EFACH Function


Modified 22219 The RNC ID parameter is added.
Fault

UMTS Cell MIMO Function


Modified 22220 The RNC ID parameter is added.
Fault

UMTS Cell DC-HSDPA


Modified 22221 The RNC ID parameter is added.
Function Fault

UMTS Cell ERACH Function


Modified 22222 The RNC ID parameter is added.
Fault

UMTS Cell EPCH Function


Modified 22223 The RNC ID parameter is added.
Fault

Modified 22231 IMB Cell Unavailable The RNC ID parameter is added.

06/22/2017 917
358680675.xls

IMB Cell Common Channel


Modified 22232 The RNC ID parameter is added.
Faulty

IMB Cell Common Channel


Modified 22233 The RNC ID parameter is added.
Setup Failed

Modified 22234 IMB Cell Setup Failed The RNC ID parameter is added.

UMTS Cell Broadcast


Modified 22502 The RNC ID parameter is added.
Service Congestion

06/22/2017 1017
358680675.xls

SPC500

Impact on NBI Data Change Reason

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.

The alarm is reserved for later version


No
upgrade.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The parameter values are added to
No instruct users on the related
troubleshooting.
The parameter values are added to
No instruct users on the related
troubleshooting.
1. The description of the alarm parameter
is modified to keep the accuracy.
No
2. The parameter values are added for
guiding users in troubleshooting.

06/22/2017 1117
358680675.xls

The parameter values are added to


No instruct users on the related
troubleshooting.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm reporting mechanism for the
Num. of Network Intelligence Processing
No
Throughput license has been changed so
that
The related alarms are
alarm reporting reported based
mechanism for the on
the total
Num. throughput
of Network of the BSC.
Intelligence Processing
No
Throughput license has been changed so
that related alarms are reported based on
The parameter
the total values
throughput of are added to
the BSC.
No instruct users on the related
troubleshooting.
The parameter values are added to
No instruct users on the related
troubleshooting.
This alarm is added to notify users that the
No actual bandwidth usage or packet loss rate
reaches a specified threshold.
The alarm is added to notify users of the
No
inconsistent board type configuration.
The alarm is added to notify users of the
No communication failure between a service
board and an SCU board.
This alarm is added for notifying users of
No MAC entries for backplane ports of the GE
switching board.
This alarm is added for notifying users of
No incorrect MAC entries for panel ports of
the GE alarm
1. This switching board. to support check
is optimized
on
Thisthe logical
alarm CPU, physical
is added memory,
for notifying usersand
of
No ejector levers of temperature.
the OMU.
abnormal board
2. If OMU External Ethernet Adapter
Alarm Switch is ON, execution of the SET
No OMUETH command with OMU External
Ethernet Adapter Alarm Switch set to
OFF can clear the alarm if the status of
This
eitheralarm
ETH0isnetcard
added to orsupport the check
ETH1 netcard is
No
on the OMU
disconnected. IP address configuration.
A function is added to check the integrity
No of the OMU application installation
package.
A function is added to support check on
consistency of the hot patch information
No
between the host and the version
description file of the OMU.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
This change prevents this alarm from
No being reported in excessively large
numbers.
This alarm is optimized to support the
No check on the communication between the
OMU and SAU boards.

06/22/2017 1217
358680675.xls

Detection is added for a subrack in


No
ineffective mode.
A consistency check is added for the
No BootRom file version between the host
and the OMU.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The
The cause for failedisIP
alarm severity PM activation
changed to is
No detailed to facilitate users' troubleshooting.
accurately reflect the alarm impact on the
The transmission resource pool feature is
network.
added, and therefore these parameters
are added to inform users for
No
troubleshooting.
The alarm severity
To support is changed
the transmission to
resource pool
accurately reflect the alarm impact
feature, the value range of the IP PATHon theID
No network.
parameter has been extended by adding a
The
new alarm parameter is added to locate
value 65536.
alarms more easily.
The parameters are added to support
No
check on various invalid packets.
The new feature ARP conflict detection is
No added. This alarm is added to alert users
to the ARP conflict.
The new feature transmission resource
pool is added. This alarm is added to alert
No
users that the ping on the IP address of an
adjacent node fails.

06/22/2017 1317
358680675.xls

The new feature transmission resource


pool is added. This alarm is added to alert
No
users that the ping on the IP path to an
The new node
adjacent feature transmission resource
fails.
pool is added. This alarm is added to alert
No users that the ping packet loss rate of an
IP address in the transmission resource
pool exceeds the threshold.
The transmission resource pool feature is
No added, and therefore this alarm is added
to prompt
The users for
transmission troubleshooting.
resource pool feature is
added, and therefore this alarm
This alarm is added to support the is added
check
No to prompt
on the SCCP users for troubleshooting
connection when
setup success
configured
rate. IP PMistasks
This alarm outnumber
generated when the
the
board
SCCP capability.
connection setup success rate is
No lower than 80% and the number of
Connection Requests (CRs) is larger than
100
This for twoisconsecutive
alarm added to alertmeasurement
users that the
No periods. (A measurement
IP address of the SCTP link period
is lasts 5
minutes.)
unreachable.
The new function that maintenance and
operation are not affected by the blocking
No or unblocking of an IP path is added. This
alarm is added to alert users that an IP
path is blocked.
This alarm is added to alert users that IP
No address in theTransmission resource pool
is blocked.
This alarm is added to alert users that
No
adjacent node is congested.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
With these changes, users are guided in
troubleshooting
The correlation is when a cellbecause
removed becomesit
No
unavailable
enables the minor alarm to masksub-
due to a faulty SPU the major
system
alarm. Asor aboard controlling
result, the minorthe NodeB.
alarm ALM-
22215 UMTS Cell Max DL Power
No
Mismatch is reported whereas the major
alarm ALM-22206 UMTS Cell Setup Failed
The alarm
is not. Thisseverity
preventsisusers
changed
fromtohandling
No accurately
cell setup failures in time. impact on the
reflect the alarm
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
This alarm is added to alert users to
inconsistency when NodeB control rights
No status of an RNC enabled with the RNC
Pool feature does not match its planned
status.
This alarm is added to alert users to the
No
DC-HSUPA function fault of a UMTS cell.

06/22/2017 1417
358680675.xls

The fault alarm is added to alert users to


No
flow control.
The alarm severity is changed to
No accurately reflect the alarm impact on the
network.
The ALM-22234 IMB Cell Setup Failed
alarm is a key alarm. Users may fail to
No
handle the IMB cell setup failure if this
alarm
This alarmis filtered out. for notifying users of
is added
DC-HSDPA function failure when the cells
No
in the same DC-HSDPA carrier group are
With these by
not served changes,
the same users SPU aresub-system.
guided in
troubleshooting when a cell becomes
No unavailable due to a faulty board where
A
thetype
MPU of sub-system
fault detection is added,the
controlling andcell is
therefore
located. this alarm is added to alert users
when the CCP in the AUDIT RESPONSE
No
message from the NodeB is inconsistent
with that at the
ALM-22206 UMTSRNCCell side during
Setup the is a
Failed
process
major of NBAP
alarm. Users audit.
may fail to handle the
No When
UMTS the cellHSDPA
setup failurefunction of aalarm
if this cell isis
faulty, the
filtered out. EFACH, ERACH, EPCH, DC-
HSDPA, and DC-HSUPA functions of that
No cell must also be faulty. After the filtering
When the HSUPA
relationship is added, function
usersofare a cell is
better
faulty,
guidedthe ERACHout
in finding and
theDC-HSUPA
root cause with
functions
fewer alarms of that cell must also be faulty.
reported.
No
After
When the EFACHrelationship
the filtering function of is added,
a cell is
users are better guided
faulty, the ERACH and EPCH functions in finding out theof
root cell
that cause must with fewer
also alarmsAfter
be faulty. reported.
the
No
filtering relationship is added, users are
A type guided
better of fault in detection
finding out is added,
the rootandcause
therefore
with fewer alarms reported. to alert users
this alarm is added
No when the BSC detects that the received
HP signal label byte over the optical port is
A type of fault detection is added, and
unstable.
therefore this alarm is added to alert users
No
when no signals are detected on an optical
port
A type tributary.
of fault detection is added, and
therefore this alarm is added to alert users
No
when
A typemultiframe loss occurs
of fault detection on anand
is added, optical
port tributary unit.
therefore this alarm is added to alert users
when the SS bit of the V1 byte (virtual
No
container
A type of fault pointer 1) configured
detection is added, on and
a BSC
board
therefore differs from
this alarm that configured
is addedout to theat the
alertcause
users
The
peer mechanism
end. for filtering
No when the MPU detects
of ALM-21581 Path Fault has been that the following
conditions
optimized. are met for an AAL2 path on the
Iu-CS interface in a measurement period
(5 minutes):
No
The number of successful QAAL2
connection setups divided by the number
of QAAL2 connection setup requests is
less than 20%.
The
Afternumber
the reported of AAL2 path setup
information requests
of the alarm
is larger than 10.
parameter Intermittent Alarm is changed,
No
users are better guided in troubleshooting.

06/22/2017 1517
358680675.xls

The change faciliates operation and


No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.

06/22/2017 1617
358680675.xls

The change faciliates operation and


No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.
The change faciliates operation and
No maintenance for users.In this way, RNC ID
and Cell ID uniquely identify a cell.

06/22/2017 1717